PortDock

System diagram editor

Place PCs, PLCs, HMIs, drives and switches on Ethernet or RS-485 buses. Checks IPs, subnets, IDs, termination and unit loads; compares before/after changes.

Add device

Configuration check

    RS-485 bus summary

    The polling estimate assumes FC03, a 10 ms device response, no extra gap and 11-bit RTU characters; devices without a register count are taken as 10. To recalculate with real response times, use the serial timing calculator.

    Compare changes — before/after expansion, replacement or removal

    Press «Use current as baseline» before the work, or open the before JSON as the baseline, to see added, removed and changed devices and links, and the bus impact (device count, unit loads, polling time) against the current diagram.

    The diagram is drawn only inside this browser and sent nowhere. It is autosaved in this browser (not visible on other PCs or browsers); use «Save JSON» to move it.

    Keyboard: arrow keys move the selection by 10 px, Delete removes it.

    What makes it different

    There are plenty of drawing tools, but field diagrams go wrong in the settings, not the shapes. This tool keeps running a configuration check while you draw — the same IP in two places, devices on one switch in different subnets (they cannot talk without a router), duplicate slave IDs or mismatched baud rate/parity on one RS-485 bus.

    RS-485 and CAN are drawn as a single bus line with devices hanging off it. Ethernet is grouped through switches and wireless APs and split at routers and cloud nodes.

    Import a PortDock Net Scan «Save CSV» file and the hosts it found are placed under a switch (types are guessed from open ports — adjust them). Save as JSON to continue later, and use SVG, PNG or print for reports.

    Give RS-485 devices «termination on», a unit load and a register count, and the tool uses their order along the bus (horizontal position) to check that both ends are terminated, that unit loads stay within 32, and to estimate one polling cycle. Buses with no termination entered are not checked for termination.

    Before an expansion, replacement or removal, press «Use current as baseline»; after editing, «Compare changes» shows added, removed and changed devices (IP, ID, baud), where an end device left and termination must move, and how much longer polling got. For the work itself, use the expansion, replacement and removal jobs in the commissioning and maintenance checklist.

    For the actual wiring between devices (termination, bias, pinouts) use the wiring diagram maker.

    To turn this setup into a start-up checklist, or to look up connector pins, use the commissioning and maintenance checklist · connector pinout reference.

    FAQ

    How is the subnet warning decided?

    Devices joined by Ethernet or Wi-Fi links are grouped through switches and APs; each IP is masked with its own subnet mask and different network addresses in one group are flagged. If no mask is given at all, /24 (255.255.255.0) is assumed and the warning says so. Anything beyond a router or cloud node is a separate group.

    Where is my diagram saved?

    Only in this browser's storage (localStorage). Nothing is uploaded, so keep the «Save JSON» file to move or archive it.

    Does the Net Scan import bring MAC addresses?

    No. Only IP, name, vendor and open ports (service names) are used. The type (PLC, router …) is guessed from open ports and marks, so it may be wrong.

    How does the comparison match devices?

    By id (kept when you edit the same file), then by the same type and name for anything left. Moving a device without changing it is not counted as a change.

    Do older JSON files still open?

    Yes. Termination, unit load and register count are optional fields, so older files open as before and can be used as a baseline.