ThreadCoarse pitchTap drillFine pitch (tap drill)Hex keySpanner
M20.41.60.25 (1.75)1.54
M2.50.452.050.35 (2.15)25
M30.52.50.35 (2.65)2.55.5
M40.73.30.5 (3.5)37
M50.84.20.5 (4.5)48
M6150.75 (5.25)510
M81.256.751 (7), 0.75 (7.25)613
M101.58.51.25 (8.75), 1 (9)816 (DIN 17)
M121.7510.251.5 (10.5), 1.25 (10.75)1018 (DIN 19)
M142121.5 (12.5)1221 (DIN 22)
M162141.5 (14.5)1424
M182.515.52 (16), 1.5 (16.5)1427
M202.517.52 (18), 1.5 (18.5)1730

The tap drill d − P is an approximation for cutting taps. In practice use the nearest drill you have and adjust for material and thread depth. Forming (roll) taps need a different drill size — see the tap maker's chart. Spanner sizes are ISO 4032; old DIN 934 nuts are 17 mm for M10, 19 mm for M12 and 22 mm for M14.

Tightening torque

Bolt torque depends on the property class (8.8, A2-70 and so on), lubrication and the mating material, and terminal blocks, breakers and contactors have their own maker-specified torque (printed on the part or in the data sheet). This chart has no torque values — check the maker's value and use a torque screwdriver.

For ring terminals that fit a stud, see the ferrule and crimp terminal chart. For inch and mm conversion, use the unit converter.

FAQ

Why is the tap drill «d − P»?

It is the usual approximation for cutting taps (nominal diameter minus pitch). In practice use the nearest drill you have and adjust for material and thread depth. Forming (roll) taps need a different drill — see the tap maker's table.

My spanner size does not match the chart

Old DIN 934 nuts use different spanner sizes from ISO 4032 for M10, M12 and M14. Check the «DIN 934» value in the chart.

Why is there no tightening torque?

It depends on the bolt property class, lubrication and mating material, and terminal blocks, breakers and contactors have their own torque from the maker. Follow the product marking or data sheet.