A PC that runs equipment stays on the plant network for years and many people touch it. From 0.10.0, Port Inspector's «This PC (equipment PC settings)» card has a «Field PC exposure (reachable from the network)» group that reads, without administrator rights, the settings through which other PCs on the network can reach this one. It only reads and changes nothing — follow each line's «Where to change» in Windows yourself. «Worth a look» does not mean «problem»; it means «check that this fits how the PC is used».
1. Item by item
| Item | What is read | «Worth a look» when | Where to change |
|---|---|---|---|
| Remote Desktop | Whether it is on, and the port (3389 by default) | On | Settings → System → Remote Desktop |
| Network Level Authentication | Whether Remote Desktop requires authentication before sign-in | Remote Desktop on without it | Settings → System → Remote Desktop → «Require devices to use Network Level Authentication to connect» |
| SMBv1 (legacy file sharing) | Whether the client and server are installed and enabled (service keys) | Either one enabled | Control Panel → Programs and Features → Turn Windows features on or off → «SMB 1.0/CIFS File Sharing Support» (administrator) |
| Firewall (per profile) | On or off for the domain, private and public profiles; the profile in use | A profile is off | Windows Security → Firewall & network protection |
| TCP ports reachable from the network | Ports listening on all addresses (0.0.0.0, ::) or a LAN address of this PC, with the program name | 502, 5006, 5007, 44818, 102, 2404, 20000, 4840, 23, 21 or 5900 open | Windows Security → Firewall & network protection → Advanced settings → Inbound rules · Command Prompt netstat -ano |
| Automatic sign-in | On or off, and whether a password value exists (contents never read) | On / a password value is in the registry | Run (Win+R) → netplwiz → «Users must enter a user name and password to use this computer» |
| USB storage AutoPlay | AutoPlay on, or blocked by policy | On and not blocked by policy | Settings → Bluetooth & devices → AutoPlay → «Use AutoPlay for all media and devices» |
The exposure group marks «Worth a look» even when the use is set to «General PC». Values that could not be read stay «not read» and are not judged (automatic sign-in is left out if it cannot be read).
2. Remote Desktop and Network Level Authentication
- Turning on Remote Desktop opens a port, so the sign-in screen can be reached from the network. Check who uses it and that the firewall limits where connections may come from.
- With Network Level Authentication (NLA) off, the sign-in screen is open to anyone before authentication. Microsoft also recommends keeping it on. If it was turned off for an old client, see whether that client can be replaced.
- Remote support tools (TeamViewer, AnyDesk …) are not read here. Check them separately.
3. SMBv1
- SMBv1 is an old file sharing protocol with many known vulnerabilities. Windows 11 does not install it by default, but some field PCs have it turned on to exchange files with an old NAS, HMI or instrument.
- Before turning it off, check whether an old device still exchanges files with the PC. If so, ask the maker whether the device can move to SMBv2 or later first.
- «Could not read the service key» means the Windows features list is administrator only. Ask an administrator to check «Turn Windows features on or off».
4. Firewall and open ports
- If the firewall is off for the profile in use, the «TCP ports reachable from the network» are open to the network as is. If an unused profile is off, the firewall will not filter when the PC joins that kind of network.
- The ports line lists TCP ports listening on all addresses (0.0.0.0, ::) or on one LAN address of this PC («@address» next to the port). Ports listening only on 127.0.0.1 cannot be reached from the network and are left out.
- Industrial protocol ports (502 Modbus TCP and others) or Telnet, FTP, VNC are «Worth a look». Check that this PC is meant to be a server (simulator, gateway) and that firewall rules limit who can reach it. If not needed, change that program's address to 127.0.0.1 or the equipment adapter's address.
- «PID n» instead of a name is a process whose name cannot be read without administrator rights. Find the PID in Task Manager's «Details» tab.
- Firewall rules are not read, so «listening» does not by itself mean reachable from outside — a rule may block it.
5. Automatic sign-in
- The PC signs in on power-up — common on equipment PCs. Anyone at the screen gets that account's rights, so check the account is not an administrator and the screen lock.
- A password value in the registry (Winlogon DefaultPassword) is «Worth a look». Microsoft's documentation says this method stores the password in plain text. PortDock only checks that the value exists and never reads it.
- If automatic sign-in is really needed, Microsoft documents another way to store it (Sysinternals Autologon, kept as an LSA secret). Make that change together with whoever manages the PC.
6. USB AutoPlay
With AutoPlay on, plugging in USB storage prompts or runs the chosen action. Since Windows 7 programs in autorun.inf do not start by themselves, but on an equipment PC where many people plug in USB drives, consider turning it off.
7. Net Scan's «Exposed» tag
- If a found device's open ports (only those already checked from the «Ports to check» list) include an unauthenticated industrial protocol or a plain-text login port, Net Scan puts an «Exposed» tag next to its IP; select the device to see what to check for each kind in the panel below.
- Where the «This PC» check asks «what has this PC opened?», Net Scan asks «what have the devices on the network opened?». It is not a device fault; it asks «who can reach this?».
- Order of checks: the equipment and office networks are separated → no router or gateway forwards the port outside → unused Telnet, FTP, VNC or HTTP can be turned off in the device and the admin page's default password was changed → OPC UA's security mode.
8. What it does not do
- It changes nothing — it reads and shows where to change.
- Firewall rules, remote access tool settings and password strength are not read.
- It is not a security product, and no «Worth a look» does not mean the PC is safe. For the network as a whole, read «Modbus, MC and XGT have no authentication» as well.
Sources
- Microsoft — Enable Remote Desktop on your PC — enabling opens a port; keep NLA on
- Microsoft — Detect, enable, and disable SMBv1, SMBv2, and SMBv3 in Windows — SMBv1 vulnerabilities, not installed by default on Windows 11, how to remove
- Microsoft — Configure Windows to automate logon — DefaultPassword stored in plain text; Autologon stores an LSA secret
- Microsoft — Windows Firewall overview — domain, private and public profiles