{"name":"PortDock device register maps","version":"2026.10","date":"2026-10-29","contentHash":"09ac1d0b2792","url":"https://portdock.dev/devices/","license":"https://creativecommons.org/licenses/by/4.0/","citation":"PortDock device register maps, v2026.10 · 09ac1d0b2792, https://portdock.dev/devices/","schema":"https://portdock.dev/data/schema.json","note":"Facts from manufacturer manuals only, each with document, edition, pages and date checked. Not affiliated with the makers. Check the device manual before writing to a device. address = 0-based wire address; value = raw × scale. version = year.month (YYYY.MM) of the latest source check. The data can change several times within one version; contentHash changes with every change, so cite version and contentHash together.","devices":[{"$schema":"../schema.json","schemaVersion":1,"id":"accuenergy/acuvim-l","manufacturer":{"ko":"어큐에너지","en":"Accuenergy"},"model":"Acuvim-L","models":["Acuvim-CL","Acuvim-DL","Acuvim-EL","Acuvim-KL"],"kind":"power-meter","title":{"ko":"어큐에너지 Acuvim-L 전력 미터 (RS-485 Modbus RTU)","en":"Accuenergy Acuvim-L power meter (RS-485 Modbus RTU)"},"summary":{"ko":"RS-485 가 있는 CL·DL·EL·KL. 2차 값 워드 표 0130h~(주파수·전압·전류·전력·역률, PT·CT 비를 곱해 실제 값), 전력량 0156h~(Dword, ÷10 kWh), 운전 시간 0180h~, 시계 0184h~. 함수 03·16(전력량·시계 쓰기), 릴레이 01·DI 02","en":"CL, DL, EL and KL with RS-485. Secondary-value word table from 0130h (frequency, voltage, current, power, PF; multiply by PT/CT ratios for actual values), energy from 0156h (Dword, /10 kWh), run time from 0180h, clock from 0184h. Functions 03 and 16 (energy, clock), relays 01, DI 02"},"protocols":["rtu"],"comm":{"bauds":[1200,2400,4800,9600,19200,38400,57600],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"order":"ABCD","addressing":"zero","notes":[{"ko":"주소 체계: 매뉴얼 예(국번 17 = 11h)의 프레임 주소가 표 주소와 같다(0 기준). 읽기 11 03 01 30 00 03 06 A8 → F·V1·V2(0130h~0132h), 응답 11 03 06 13 88 03 E7 03 E9 7F 04(50.00 Hz·99.9 V·100.1 V), 쓰기 11 10 01 56 00 02 04 0A 9D 40 89 4D B9 → Ep_imp(0156h·0157h), 릴레이 11 01 00 00 00 02 BF 5B, DI 11 02 00 00 00 04 7B 59 (인쇄 p.90~93). 이 요청들의 CRC 는 계산값과 같다.","en":"Addressing: frame addresses in the manual examples (slave 17 = 11h) equal the table addresses (0-based). Read 11 03 01 30 00 03 06 A8 → F, V1, V2 (0130h-0132h), reply 11 03 06 13 88 03 E7 03 E9 7F 04 (50.00 Hz, 99.9 V, 100.1 V); write 11 10 01 56 00 02 04 0A 9D 40 89 4D B9 → Ep_imp (0156h/0157h); relays 11 01 00 00 00 02 BF 5B; DI 11 02 00 00 00 04 7B 59 (printed pp.90-93). The CRCs of these requests match calculation."},{"ko":"매뉴얼 응답 예 세 곳의 오타: 릴레이 응답(11 01 01 02)의 CRC 를 요청과 같은 BF 5B 로 적음(계산 D4 89), DI 응답의 함수 코드를 01 로 적음(CRC E5 49 는 02 로 계산한 값), FC16 응답의 시작 주소를 010Ch 로 적음(CRC A2 B4 는 0156h 로 계산한 값). 표의 CRC 칸 이름은 Hi·Lo 지만 실제로는 하위 바이트를 먼저 보낸다(인쇄 p.89 설명과 같음).","en":"Three typos in the manual's reply examples: the relay reply (11 01 01 02) repeats the request CRC BF 5B (calculated D4 89); the DI reply shows function 01 (its CRC E5 49 is calculated with 02); the FC16 reply shows start 010Ch (its CRC A2 B4 is calculated with 0156h). The CRC columns are labelled Hi/Lo, but the low byte is sent first, as the text on printed p.89 says."},{"ko":"통신 설정(인쇄 p.48~49): 국번 1~247, 속도 1200~57600 bps, 데이터 8비트, 검사 non1(패리티 없음·정지 1)·non2(없음·정지 2)·odd·EVEN — 출하값 EVEN(이 화면은 EL·KL). 출하 속도는 매뉴얼에서 찾지 못해 비웠다. 함수 코드는 01·02·03·16 (표 4-2, 인쇄 p.87).","en":"Communication settings (printed pp.48-49): address 1-247, 1200-57600 bps, 8 data bits, check non1 (no parity, 1 stop), non2 (no parity, 2 stop), odd or EVEN, default EVEN (this screen on EL/KL). The default baud rate was not found in the manual, so it is left empty. Function codes 01, 02, 03 and 16 (Table 4-2, printed p.87)."}]},"registers":[{"table":"holding-registers","address":304,"manualAddress":"0130H","type":"u16","name":{"ko":"주파수 F","en":"Frequency F"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"range":{"min":45,"max":65},"description":{"ko":"F = Rx ÷ 100. 매뉴얼 읽기 예(4-8·4-9)에서 1388h = 50.00 Hz","en":"F = Rx / 100. In the manual read example (4-8, 4-9) 1388h = 50.00 Hz"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":305,"manualAddress":"0131H","type":"u16","name":{"ko":"상전압 V1","en":"Phase voltage V1"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) ÷ 10 [V]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) / 10 [V]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":306,"manualAddress":"0132H","type":"u16","name":{"ko":"상전압 V2","en":"Phase voltage V2"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) ÷ 10 [V]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) / 10 [V]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":307,"manualAddress":"0133H","type":"u16","name":{"ko":"상전압 V3","en":"Phase voltage V3"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) ÷ 10 [V]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) / 10 [V]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":308,"manualAddress":"0134H","type":"u16","name":{"ko":"선간 전압 V12","en":"Line voltage V12"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) ÷ 10 [V]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) / 10 [V]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":309,"manualAddress":"0135H","type":"u16","name":{"ko":"선간 전압 V23","en":"Line voltage V23"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) ÷ 10 [V]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) / 10 [V]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":310,"manualAddress":"0136H","type":"u16","name":{"ko":"선간 전압 V31","en":"Line voltage V31"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) ÷ 10 [V]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) / 10 [V]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":311,"manualAddress":"0137H","type":"u16","name":{"ko":"전류 I1","en":"Current I1"},"unit":"A","scale":0.001,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (CT1/CT2) ÷ 1000 [A]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (CT1/CT2) / 1000 [A]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":312,"manualAddress":"0138H","type":"u16","name":{"ko":"전류 I2","en":"Current I2"},"unit":"A","scale":0.001,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (CT1/CT2) ÷ 1000 [A]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (CT1/CT2) / 1000 [A]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":313,"manualAddress":"0139H","type":"u16","name":{"ko":"전류 I3","en":"Current I3"},"unit":"A","scale":0.001,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (CT1/CT2) ÷ 1000 [A]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (CT1/CT2) / 1000 [A]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":314,"manualAddress":"013AH","type":"u16","name":{"ko":"중성선 전류 In","en":"Neutral current In"},"unit":"A","scale":0.001,"access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (CT1/CT2) ÷ 1000 [A]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (CT1/CT2) / 1000 [A]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":315,"manualAddress":"013BH","type":"s16","name":{"ko":"A상 유효 전력 Pa","en":"Phase A active power Pa"},"unit":"W","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [W]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [W]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":316,"manualAddress":"013CH","type":"s16","name":{"ko":"B상 유효 전력 Pb","en":"Phase B active power Pb"},"unit":"W","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [W]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [W]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":317,"manualAddress":"013DH","type":"s16","name":{"ko":"C상 유효 전력 Pc","en":"Phase C active power Pc"},"unit":"W","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [W]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [W]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":318,"manualAddress":"013EH","type":"s16","name":{"ko":"합계 유효 전력 Psum","en":"Total active power Psum"},"unit":"W","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [W]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [W]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":319,"manualAddress":"013FH","type":"s16","name":{"ko":"A상 무효 전력 Qa","en":"Phase A reactive power Qa"},"unit":"var","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [var]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [var]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":320,"manualAddress":"0140H","type":"s16","name":{"ko":"B상 무효 전력 Qb","en":"Phase B reactive power Qb"},"unit":"var","access":"r","fc":[3],"description":{"ko":"Rx × (PT1/PT2) × (CT1/CT2) [var]. 표 4-26 은 13Fh·140h 를 둘 다 Qa, 141h 를 Qb 로 적었다 — 같은 순서의 1차 값 표 4-28(061Eh Qa·0620h Qb·0622h Qc)에 맞춰 140h = Qb, 141h = Qc 로 두었다","en":"Rx × (PT1/PT2) × (CT1/CT2) [var]. Table 4-26 labels both 13Fh and 140h as Qa and 141h as Qb; following the same order in primary Table 4-28 (061Eh Qa, 0620h Qb, 0622h Qc), 140h = Qb and 141h = Qc"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":321,"manualAddress":"0141H","type":"s16","name":{"ko":"C상 무효 전력 Qc","en":"Phase C reactive power Qc"},"unit":"var","access":"r","fc":[3],"description":{"ko":"Rx × (PT1/PT2) × (CT1/CT2) [var]. 표 4-26 은 13Fh·140h 를 둘 다 Qa, 141h 를 Qb 로 적었다 — 같은 순서의 1차 값 표 4-28(061Eh Qa·0620h Qb·0622h Qc)에 맞춰 140h = Qb, 141h = Qc 로 두었다","en":"Rx × (PT1/PT2) × (CT1/CT2) [var]. Table 4-26 labels both 13Fh and 140h as Qa and 141h as Qb; following the same order in primary Table 4-28 (061Eh Qa, 0620h Qb, 0622h Qc), 140h = Qb and 141h = Qc"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":322,"manualAddress":"0142H","type":"s16","name":{"ko":"합계 무효 전력 Qsum","en":"Total reactive power Qsum"},"unit":"var","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [var]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [var]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":323,"manualAddress":"0143H","type":"u16","name":{"ko":"합계 피상 전력 Ssum","en":"Total apparent power Ssum"},"unit":"VA","access":"r","fc":[3],"description":{"ko":"PT1/PT2·CT1/CT2 가 1 일 때의 배율. 실제 값 = Rx × (PT1/PT2) × (CT1/CT2) [VA]","en":"Scale when PT1/PT2 and CT1/CT2 are 1. Actual value = Rx × (PT1/PT2) × (CT1/CT2) [VA]"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":324,"manualAddress":"0144H","type":"s16","name":{"ko":"A상 역률 PFa","en":"Phase A power factor PFa"},"scale":0.001,"access":"r","fc":[3],"range":{"min":-1,"max":1},"description":{"ko":"PF = Rx ÷ 1000 (−1000~1000)","en":"PF = Rx / 1000 (−1000 to 1000)"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":325,"manualAddress":"0145H","type":"s16","name":{"ko":"B상 역률 PFb","en":"Phase B power factor PFb"},"scale":0.001,"access":"r","fc":[3],"range":{"min":-1,"max":1},"description":{"ko":"PF = Rx ÷ 1000 (−1000~1000)","en":"PF = Rx / 1000 (−1000 to 1000)"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":326,"manualAddress":"0146H","type":"s16","name":{"ko":"C상 역률 PFc","en":"Phase C power factor PFc"},"scale":0.001,"access":"r","fc":[3],"range":{"min":-1,"max":1},"description":{"ko":"PF = Rx ÷ 1000 (−1000~1000)","en":"PF = Rx / 1000 (−1000 to 1000)"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":327,"manualAddress":"0147H","type":"s16","name":{"ko":"합계 역률 PFsum","en":"System power factor PFsum"},"scale":0.001,"access":"r","fc":[3],"range":{"min":-1,"max":1},"description":{"ko":"PF = Rx ÷ 1000 (−1000~1000)","en":"PF = Rx / 1000 (−1000 to 1000)"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":328,"manualAddress":"0148H","type":"u16","name":{"ko":"전압 불평형률","en":"Voltage unbalance factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"Unbl = Rx ÷ 1000 × 100 %","en":"Unbl = Rx / 1000 × 100 %"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":329,"manualAddress":"0149H","type":"u16","name":{"ko":"전류 불평형률","en":"Current unbalance factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"Unbl = Rx ÷ 1000 × 100 %","en":"Unbl = Rx / 1000 × 100 %"},"ref":"인쇄 p.135~136 표 4-26·4-27 (PDF p.143~144)","source":0},{"table":"holding-registers","address":330,"manualAddress":"014AH","type":"u16","name":{"ko":"부하 성질","en":"Load nature"},"access":"r","fc":[3],"values":[{"value":76,"ko":"L (유도성)","en":"L (inductive)"},{"value":67,"ko":"C (용량성)","en":"C (capacitive)"},{"value":82,"ko":"R (저항성)","en":"R (resistive)"}],"ref":"인쇄 p.136 (PDF p.144)","source":0},{"table":"holding-registers","address":342,"manualAddress":"0156H","type":"u32","order":"ABCD","name":{"ko":"유효 전력량(수전) Ep_imp","en":"Import active energy Ep_imp"},"unit":"kWh","scale":0.1,"access":"rw","fc":[3,16],"description":{"ko":"Dword, 상위 워드 먼저. 실제 값 = Rx ÷ 10. 쓰기(FC16) 예: 0156h·0157h 에 0A9D 4089h = 17807783.3 kWh(인쇄 p.93)","en":"Dword, high word first. Actual value = Rx / 10. Write (FC16) example: 0A9D 4089h = 17807783.3 kWh to 0156h/0157h (printed p.93)"},"ref":"인쇄 p.146~147 표 4-37·4-38 (PDF p.154~155)","source":0},{"table":"holding-registers","address":344,"manualAddress":"0158H","type":"u32","order":"ABCD","name":{"ko":"유효 전력량(송전) Ep_exp","en":"Export active energy Ep_exp"},"unit":"kWh","scale":0.1,"access":"rw","fc":[3,16],"description":{"ko":"Dword, 상위 워드 먼저. 실제 값 = Rx ÷ 10","en":"Dword, high word first. Actual value = Rx / 10"},"ref":"인쇄 p.146~147 표 4-37·4-38 (PDF p.154~155)","source":0},{"table":"holding-registers","address":346,"manualAddress":"015AH","type":"u32","order":"ABCD","name":{"ko":"무효 전력량(수전) Eq_imp","en":"Import reactive energy Eq_imp"},"unit":"kvarh","scale":0.1,"access":"rw","fc":[3,16],"ref":"인쇄 p.146~147 표 4-37·4-38 (PDF p.154~155)","source":0},{"table":"holding-registers","address":348,"manualAddress":"015CH","type":"u32","order":"ABCD","name":{"ko":"무효 전력량(송전) Eq_exp","en":"Export reactive energy Eq_exp"},"unit":"kvarh","scale":0.1,"access":"rw","fc":[3,16],"ref":"인쇄 p.146~147 표 4-37·4-38 (PDF p.154~155)","source":0},{"table":"holding-registers","address":350,"manualAddress":"015EH","type":"u32","order":"ABCD","name":{"ko":"피상 전력량 Es","en":"Apparent energy Es"},"unit":"kVAh","scale":0.1,"access":"rw","fc":[3,16],"ref":"인쇄 p.146~147 표 4-37·4-38 (PDF p.154~155)","source":0},{"table":"holding-registers","address":384,"manualAddress":"0180H","type":"u32","order":"ABCD","name":{"ko":"계기 운전 시간","en":"Meter run time"},"unit":"h","scale":0.1,"access":"r","fc":[3],"description":{"ko":"상위 16비트(180h)·하위 16비트(181h). Run_Hur = Rx ÷ 10","en":"High 16 bits (180h), low 16 bits (181h). Run_Hur = Rx / 10"},"ref":"인쇄 p.142 표 4-33·4-34 (PDF p.150)","source":0},{"table":"holding-registers","address":386,"manualAddress":"0182H","type":"u32","order":"ABCD","name":{"ko":"부하 운전 시간","en":"Load run time"},"unit":"h","scale":0.1,"access":"r","fc":[3],"description":{"ko":"상위 16비트(182h)·하위 16비트(183h). Rx ÷ 10","en":"High 16 bits (182h), low 16 bits (183h). Rx / 10"},"ref":"인쇄 p.142 표 4-33·4-34 (PDF p.150)","source":0},{"table":"holding-registers","address":388,"manualAddress":"0184H","type":"u16","name":{"ko":"시계 — 연","en":"Clock — Year"},"access":"rw","fc":[3,16],"range":{"min":2000,"max":2099},"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"holding-registers","address":389,"manualAddress":"0185H","type":"u16","name":{"ko":"시계 — 월","en":"Clock — Month"},"access":"rw","fc":[3,16],"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"holding-registers","address":390,"manualAddress":"0186H","type":"u16","name":{"ko":"시계 — 일","en":"Clock — Day"},"access":"rw","fc":[3,16],"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"holding-registers","address":391,"manualAddress":"0187H","type":"u16","name":{"ko":"시계 — 시","en":"Clock — Hour"},"access":"rw","fc":[3,16],"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"holding-registers","address":392,"manualAddress":"0188H","type":"u16","name":{"ko":"시계 — 분","en":"Clock — Minute"},"access":"rw","fc":[3,16],"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"holding-registers","address":393,"manualAddress":"0189H","type":"u16","name":{"ko":"시계 — 초","en":"Clock — Second"},"access":"rw","fc":[3,16],"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"holding-registers","address":394,"manualAddress":"018AH","type":"u16","name":{"ko":"시계 — 요일","en":"Clock — Week"},"access":"rw","fc":[3,16],"ref":"인쇄 p.144 표 4-36 (PDF p.152)","source":0},{"table":"coils","address":0,"manualAddress":"0000H","type":"bit","name":{"ko":"릴레이 1 상태","en":"Relay 1 status"},"access":"r","fc":[1],"description":{"ko":"1 = ON. DL·EL 확장 IO. 읽기 예 11 01 00 00 00 02 BF 5B(인쇄 p.90)","en":"1 = ON. DL/EL extended IO. Read example 11 01 00 00 00 02 BF 5B (printed p.90)"},"ref":"인쇄 p.90~91 표 4-4·4-5 (PDF p.98~99)","source":0},{"table":"coils","address":1,"manualAddress":"0001H","type":"bit","name":{"ko":"릴레이 2 상태","en":"Relay 2 status"},"access":"r","fc":[1],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"인쇄 p.90 (PDF p.98)","source":0},{"table":"discrete-inputs","address":0,"manualAddress":"0000H","type":"bit","name":{"ko":"디지털 입력 DI1","en":"Digital input DI1"},"access":"r","fc":[2],"description":{"ko":"1 = ON. 읽기 예 11 02 00 00 00 04 7B 59(인쇄 p.91)","en":"1 = ON. Read example 11 02 00 00 00 04 7B 59 (printed p.91)"},"ref":"인쇄 p.91~92 표 4-6·4-7 (PDF p.99~100)","source":0},{"table":"discrete-inputs","address":1,"manualAddress":"0001H","type":"bit","name":{"ko":"디지털 입력 DI2","en":"Digital input DI2"},"access":"r","fc":[2],"ref":"인쇄 p.91~92 표 4-6·4-7 (PDF p.99~100)","source":0},{"table":"discrete-inputs","address":2,"manualAddress":"0002H","type":"bit","name":{"ko":"디지털 입력 DI3","en":"Digital input DI3"},"access":"r","fc":[2],"ref":"인쇄 p.91~92 표 4-6·4-7 (PDF p.99~100)","source":0},{"table":"discrete-inputs","address":3,"manualAddress":"0003H","type":"bit","name":{"ko":"디지털 입력 DI4","en":"Digital input DI4"},"access":"r","fc":[2],"ref":"인쇄 p.91~92 표 4-6·4-7 (PDF p.99~100)","source":0}],"notes":[{"ko":"0130h~ 표는 2차 쪽 값이다: 전압 = Rx × (PT1/PT2) ÷ 10, 전류 = Rx × (CT1/CT2) ÷ 1000, 전력 = Rx × (PT1/PT2) × (CT1/CT2) (표 4-27). 여기 적은 배율은 PT·CT 없이 직접 연결(비 1)일 때 값이므로, CT 를 쓰면 읽은 값에 CT 비(와 PT 비)를 곱한다. CT2 = 333(mV CT)이면 1 로 본다.","en":"The 0130h table holds secondary-side values: voltage = Rx × (PT1/PT2) / 10, current = Rx × (CT1/CT2) / 1000, power = Rx × (PT1/PT2) × (CT1/CT2) (Table 4-27). The scales given here assume direct connection (ratio 1); with CTs, multiply readings by the CT ratio (and PT ratio). CT2 = 333 (mV CT) counts as 1."},{"ko":"1차 값(실제 단위) Float 표 0600h~(표 4-28)도 있지만 매뉴얼에 Float 의 워드 순서가 적혀 있지 않아 넣지 않았다. 설정 표 0100h~(표 4-35)는 쪽에 주소와 이름이 한 줄씩 어긋나 있어 뺐다.","en":"A primary-value (actual units) Float table from 0600h (Table 4-28) exists, but the manual does not state the float word order, so it is left out. The settings table from 0100h (Table 4-35) has addresses and names shifted by a row on the page, so it is left out too."},{"ko":"쪽 번호는 인쇄 쪽(PDF 쪽 = 인쇄 쪽 + 8). 이더넷 모듈(AXM-NET)의 Modbus TCP 는 이 파일에 넣지 않았다.","en":"Page numbers are printed pages (PDF page = printed + 8). Modbus TCP through the Ethernet module (AXM-NET) is not covered here."}],"sources":[{"title":"Acuvim-L Series Power Meter User's Manual","publisher":"Accuenergy","edition":{"ko":"V2.01, Document #1030E2201, 개정일 2013-04","en":"V2.01, Document #1030E2201, revision date Apr 2013"},"url":"https://www.accuenergy.com/wp-content/uploads/Acuvim-L-Panel-Submeter-Power-Energy-Meter-User-Manual1030E2201.pdf","pages":{"ko":"인쇄 p.48~49 통신 설정, p.86~93 Modbus·프레임 예, p.134~147 주소표 (PDF p.56~57, 94~101, 142~155)","en":"printed pp.48-49 comm settings, pp.86-93 Modbus and frame examples, pp.134-147 address tables (PDF pp.56-57, 94-101, 142-155)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/ct","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"CT Series","models":["CT4□-□□T","CT6□-□□T"],"kind":"other","title":{"ko":"오토닉스 CT 시리즈 카운터/타이머 (RS485 통신 모델)","en":"Autonics CT Series counter/timer (RS485 communication models)"},"summary":{"ko":"프리셋 카운터·타이머. 형번 끝이 T 인 통신 모델이 RS485 Modbus RTU. 코일(리셋·출력), 입력 접점(단자 입력), 입력 레지스터(현재값·프리셋·표시 상태), 보유 레지스터(프리셋·카운터 설정·통신 설정)를 담았다.","en":"Preset counter/timer; models ending in T have RS485 Modbus RTU. Covers coils (reset, outputs), discrete inputs (terminal inputs), input registers (present value, presets, indicators) and holding registers (presets, counter settings, comm)."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,127],"order":"CDAB","notes":[{"ko":"통신 사양·기본값: 제품 매뉴얼 TCD220014AC «Communication Interface»·통신 파라미터 표 — 9600 bps 기본, 데이터 8비트 고정, 패리티 None 기본, 정지 2비트 기본, 응답 대기 20 ms, 국번 001(1~127), 최대 31대.","en":"Comm spec/defaults from product manual TCD220014AC: 9600 bps, 8 data bits fixed, parity none, 2 stop bits, response wait 20 ms, address 001 (1-127), up to 31 units."},{"ko":"매뉴얼은 «400001 (0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(통신 매뉴얼 pp.21-27). 1.1 절 프레임 예시는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «400001 (0000)»: 1-based reference plus hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (pp.21-27). Frame examples show layout only."},{"ko":"2워드 값은 낮은 주소가 하위 워드(예: 301004 하위, 301005 상위) — order CDAB (p.24).","en":"2-word values put the low word at the lower address (e.g. 301004 low, 301005 high), i.e. CDAB (p.24)."},{"ko":"브로드캐스트 명령을 지원하지 않는다(통신 매뉴얼 p.v).","en":"Broadcast is not supported (comm manual p.v)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"000001 (0000)","type":"bit","name":{"ko":"리셋","en":"Reset"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"FC05 로 ON(FF00h) 을 쓰면 리셋.","en":"Write ON (FF00h) with FC05 to reset."},"ref":"p.21 2.1"},{"table":"coils","address":1,"manualAddress":"000002 (0001)","type":"bit","name":{"ko":"OUT2 출력","en":"OUT2 output"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.1"},{"table":"coils","address":2,"manualAddress":"000003 (0002)","type":"bit","name":{"ko":"OUT1 출력","en":"OUT1 output"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.1"},{"table":"coils","address":3,"manualAddress":"000004 (0003)","type":"bit","name":{"ko":"BATCH 출력","en":"BATCH output"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"BATCH 출력 모델","en":"BATCH output models"},"ref":"p.21 2.1"},{"table":"coils","address":4,"manualAddress":"000005 (0004)","type":"bit","name":{"ko":"BATCH 리셋","en":"BATCH reset"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"BATCH 출력 모델. FC05 로 ON(FF00h) 을 쓰면 리셋.","en":"BATCH output models; write ON (FF00h) with FC05 to reset."},"ref":"p.21 2.1"},{"table":"discrete-inputs","address":0,"manualAddress":"100001 (0000)","type":"bit","name":{"ko":"INA 입력","en":"INA input status"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.2"},{"table":"discrete-inputs","address":1,"manualAddress":"100002 (0001)","type":"bit","name":{"ko":"INB 입력","en":"INB input status"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.2"},{"table":"discrete-inputs","address":2,"manualAddress":"100003 (0002)","type":"bit","name":{"ko":"INHIBIT 입력","en":"INHIBIT input status"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.2"},{"table":"discrete-inputs","address":3,"manualAddress":"100004 (0003)","type":"bit","name":{"ko":"RESET 입력","en":"RESET input status"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.2"},{"table":"discrete-inputs","address":4,"manualAddress":"100005 (0004)","type":"bit","name":{"ko":"BATCH RESET 입력","en":"BATCH RESET input status"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.21 2.2"},{"table":"input-registers","address":1000,"manualAddress":"301001 (03E8)","type":"u16","name":{"ko":"표시등 상태 비트","en":"LED display status bits"},"access":"r","fc":[4],"bits":[{"bit":5,"ko":"BA.O","en":"BA.O"},{"bit":6,"ko":"OUT2","en":"OUT2"},{"bit":7,"ko":"OUT1","en":"OUT1"},{"bit":10,"ko":"BA.S","en":"BA.S"},{"bit":11,"ko":"LOCK","en":"LOCK"},{"bit":12,"ko":"PRESET2","en":"PRESET2"},{"bit":13,"ko":"PRESET1","en":"PRESET1"},{"bit":14,"ko":"TMR","en":"TMR"},{"bit":15,"ko":"CNT","en":"CNT"}],"description":{"ko":"비트 형식은 p.24 표.","en":"Bit layout per the table on p.24."},"ref":"p.23 2.4"},{"table":"input-registers","address":1001,"manualAddress":"301002 (03E9)","type":"u32","order":"CDAB","name":{"ko":"BATCH 카운터 현재값","en":"BATCH counter present value"},"access":"r","fc":[4],"range":{"min":0,"max":999999},"description":{"ko":"BATCH 출력 모델. 2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"BATCH output models. 2-word value; lower address holds the low word (p.24)."},"ref":"p.23 2.4"},{"table":"input-registers","address":1003,"manualAddress":"301004 (03EB)","type":"s32","order":"CDAB","name":{"ko":"카운터/타이머 현재값","en":"Counter/timer present value"},"access":"r","fc":[4],"description":{"ko":"카운터: 6자리형 -99999~999999, 4자리형 -999~9999 / 타이머: 시간 설정 범위 안. 2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"Counter: 6-digit -99999..999999, 4-digit -999..9999 / timer: within time range. 2-word value; lower address holds the low word (p.24)."},"ref":"p.23 2.4"},{"table":"input-registers","address":1005,"manualAddress":"301006 (03ED)","type":"u16","name":{"ko":"표시 단위","en":"Display unit"},"access":"r","fc":[4],"description":{"ko":"카운터: 표시값 소수점(400058), 타이머: 시간 범위(400102).","en":"Counter: decimal point of display value (400058); timer: time range (400102)."},"ref":"p.23 2.4"},{"table":"input-registers","address":1006,"manualAddress":"301007 (03EE)","type":"s32","order":"CDAB","name":{"ko":"PRESET2 설정값","en":"PRESET2 setting value"},"access":"r","fc":[4],"description":{"ko":"카운터: 6자리형 -99999~999999, 4자리형 -999~9999 / 타이머: 시간 설정 범위 안. 2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"Counter: 6-digit -99999..999999, 4-digit -999..9999 / timer: within time range. 2-word value; lower address holds the low word (p.24)."},"ref":"p.23 2.4"},{"table":"input-registers","address":1008,"manualAddress":"301009 (03F0)","type":"s32","order":"CDAB","name":{"ko":"PRESET1 설정값","en":"PRESET1 setting value"},"access":"r","fc":[4],"description":{"ko":"카운터: 6자리형 -99999~999999, 4자리형 -999~9999 / 타이머: 시간 설정 범위 안. 2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"Counter: 6-digit -99999..999999, 4-digit -999..9999 / timer: within time range. 2-word value; lower address holds the low word (p.24)."},"ref":"p.23 2.4"},{"table":"input-registers","address":1010,"manualAddress":"301011 (03F2)","type":"u32","order":"CDAB","name":{"ko":"BATCH 카운터 설정값","en":"BATCH counter setting value"},"access":"r","fc":[4],"range":{"min":0,"max":999999},"description":{"ko":"2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"2-word value; lower address holds the low word (p.24)."},"ref":"p.23 2.4"},{"table":"input-registers","address":1012,"manualAddress":"301013 (03F4)","type":"u16","name":{"ko":"입력 로직","en":"Input logic"},"access":"r","fc":[4],"values":[{"value":0,"ko":"NPN","en":"NPN"},{"value":1,"ko":"PNP","en":"PNP"}],"ref":"p.23 2.4"},{"table":"holding-registers","address":0,"manualAddress":"400001 (0000)","type":"u32","order":"CDAB","name":{"ko":"PRESET2 설정값","en":"PRESET2 setting value"},"access":"rw","fc":[3,16],"description":{"ko":"카운터: 6자리형 0~999999, 4자리형 0~9999 / 타이머: 시간 설정 범위 안. 2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"Counter: 6-digit 0..999999, 4-digit 0..9999 / timer: within time range. 2-word value; lower address holds the low word (p.24)."},"ref":"p.24 2.5"},{"table":"holding-registers","address":2,"manualAddress":"400003 (0002)","type":"u32","order":"CDAB","name":{"ko":"PRESET1 설정값","en":"PRESET1 setting value"},"access":"rw","fc":[3,16],"description":{"ko":"카운터: 6자리형 0~999999, 4자리형 0~9999 / 타이머: 시간 설정 범위 안. 2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"Counter: 6-digit 0..999999, 4-digit 0..9999 / timer: within time range. 2-word value; lower address holds the low word (p.24)."},"ref":"p.24 2.5"},{"table":"holding-registers","address":4,"manualAddress":"400005 (0004)","type":"u32","order":"CDAB","name":{"ko":"BATCH 카운터 설정값","en":"BATCH counter setting value"},"access":"rw","fc":[3,16],"range":{"min":0,"max":999999},"description":{"ko":"2워드 값 — 낮은 주소가 하위 워드(p.24).","en":"2-word value; lower address holds the low word (p.24)."},"ref":"p.24 2.5"},{"table":"holding-registers","address":50,"manualAddress":"400051 (0032)","type":"u16","name":{"ko":"카운터/타이머 선택","en":"Counter/Timer [C-T]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"카운터(COUN)","en":"Counter (COUN)"},{"value":1,"ko":"타이머(TIME)","en":"Timer (TIME)"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":51,"manualAddress":"400052 (0033)","type":"u16","name":{"ko":"입력 모드","en":"Input mode [IN]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"UP","en":"UP"},{"value":1,"ko":"UP-1","en":"UP-1"},{"value":2,"ko":"UP-2","en":"UP-2"},{"value":3,"ko":"DN","en":"DN"},{"value":4,"ko":"DN-1","en":"DN-1"},{"value":5,"ko":"DN-2","en":"DN-2"},{"value":6,"ko":"UD-A","en":"UD-A"},{"value":7,"ko":"UD-B","en":"UD-B"},{"value":8,"ko":"UD-C","en":"UD-C"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":52,"manualAddress":"400053 (0034)","type":"u16","name":{"ko":"표시 모드 (표시기형)","en":"Indication mode (indicator)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"TOTAL","en":"TOTAL"},{"value":1,"ko":"HOLD","en":"HOLD"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":53,"manualAddress":"400054 (0035)","type":"u16","name":{"ko":"출력 모드","en":"Output mode [OUTM]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"F","en":"F"},{"value":1,"ko":"N","en":"N"},{"value":2,"ko":"C","en":"C"},{"value":3,"ko":"R","en":"R"},{"value":4,"ko":"K","en":"K"},{"value":5,"ko":"P","en":"P"},{"value":6,"ko":"Q","en":"Q"},{"value":7,"ko":"A","en":"A"},{"value":8,"ko":"S","en":"S"},{"value":9,"ko":"T","en":"T"},{"value":10,"ko":"D","en":"D"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":54,"manualAddress":"400055 (0036)","type":"u16","name":{"ko":"최고 계수 속도","en":"Max. counting speed [CPS]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1 cps","en":"1 cps"},{"value":1,"ko":"30 cps","en":"30 cps"},{"value":2,"ko":"1k cps","en":"1k cps"},{"value":3,"ko":"5k cps","en":"5k cps"},{"value":4,"ko":"10k cps","en":"10k cps"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":55,"manualAddress":"400056 (0037)","type":"u16","name":{"ko":"OUT2 출력 시간","en":"OUT2 output time"},"unit":"s","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0.01,"max":99.99},"description":{"ko":"단위 ×10 ms (0.01~99.99 s)","en":"Unit ×10 ms (0.01-99.99 s)"},"ref":"p.25 2.6.1"},{"table":"holding-registers","address":56,"manualAddress":"400057 (0038)","type":"u16","name":{"ko":"OUT1 출력 시간","en":"OUT1 output time"},"unit":"s","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0.01,"max":99.99},"description":{"ko":"단위 ×10 ms (0.01~99.99 s)","en":"Unit ×10 ms (0.01-99.99 s)"},"ref":"p.25 2.6.1"},{"table":"holding-registers","address":57,"manualAddress":"400058 (0039)","type":"u16","name":{"ko":"소수점","en":"Decimal point [DP]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"------","en":"------"},{"value":1,"ko":"-----.-","en":"-----.-"},{"value":2,"ko":"----.--","en":"----.--"},{"value":3,"ko":"---.---","en":"---.---"},{"value":4,"ko":"--.----","en":"--.----"},{"value":5,"ko":"-.-----","en":"-.-----"}],"description":{"ko":"6자리형 표기. 4자리형: 0 ----, 1 ---.-, 2 --.--, 3 -.---","en":"6-digit notation; 4-digit: 0 ----, 1 ---.-, 2 --.--, 3 -.---"},"ref":"p.25 2.6.1"},{"table":"holding-registers","address":58,"manualAddress":"400059 (003A)","type":"u16","name":{"ko":"최소 리셋 시간","en":"Min. reset time [RST]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1 ms","en":"1 ms"},{"value":1,"ko":"20 ms","en":"20 ms"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":64,"manualAddress":"400065 (0040)","type":"u16","name":{"ko":"메모리 보호","en":"Memory protection [DATA]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"CLR","en":"CLR"},{"value":1,"ko":"REC","en":"REC"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":65,"manualAddress":"400066 (0041)","type":"u16","name":{"ko":"키 잠금","en":"Lock key [LOCK]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"LOFF","en":"LOFF"},{"value":1,"ko":"LOC1","en":"LOC1"},{"value":2,"ko":"LOC2","en":"LOC2"},{"value":3,"ko":"LOC3","en":"LOC3"}],"ref":"p.25 2.6.1"},{"table":"holding-registers","address":100,"manualAddress":"400101 (0064)","type":"u16","name":{"ko":"카운터/타이머 선택(타이머 그룹)","en":"Counter/Timer [C-T] (timer group)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"카운터(COUN)","en":"Counter (COUN)"},{"value":1,"ko":"타이머(TIME)","en":"Timer (TIME)"}],"ref":"p.26 2.6.2"},{"table":"holding-registers","address":150,"manualAddress":"400151 (0096)","type":"u16","name":{"ko":"통신 국번","en":"Comm. address [ADDR]"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":127},"ref":"p.27 2.6.3"},{"table":"holding-registers","address":151,"manualAddress":"400152 (0097)","type":"u16","name":{"ko":"통신 속도","en":"Comm. speed [BPS]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"}],"ref":"p.27 2.6.3"},{"table":"holding-registers","address":152,"manualAddress":"400153 (0098)","type":"u16","name":{"ko":"패리티","en":"Comm. parity bit [PRTY]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"p.27 2.6.3"},{"table":"holding-registers","address":153,"manualAddress":"400154 (0099)","type":"u16","name":{"ko":"정지 비트","en":"Comm. stop bit [STP]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"p.27 2.6.3"},{"table":"holding-registers","address":154,"manualAddress":"400155 (009A)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response waiting time [RSWT]"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.27 2.6.3"},{"table":"holding-registers","address":155,"manualAddress":"400156 (009B)","type":"u16","name":{"ko":"통신 쓰기 허용","en":"Comm. writing [COMW]"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"허용","en":"ENA"},{"value":1,"ko":"금지","en":"DISA"}],"ref":"p.27 2.6.3"}],"notes":[{"ko":"RS485 는 ⑤ 통신 코드 T 모델만(제품 매뉴얼 주문 정보: CT ①자리 ②크기 - ③출력 ④전원 ⑤T). models 의 □ 는 크기(S·Y·M)·출력(1P·2P·I)·전원(2·4) — 모든 조합이 있는 것은 아니다.","en":"RS485 only on models with communication code T (ordering: CT ① digits ② size - ③ output ④ power ⑤ T). In models, □ = size (S/Y/M), output (1P/2P/I), power (2/4); not all combinations exist."},{"ko":"카운터 그룹(2.6.1)·타이머 그룹(2.6.2) 값을 FC06·16 으로 바꾸면 화면에 COMW·RST 가 3초 깜박이고 현재값이 리셋된다. 프리셋·통신 그룹은 현재값 유지 (p.27).","en":"Changing counter/timer group values via FC06/16 flashes COMW/RST for 3 s and resets the present value; preset/comm group changes keep it (p.27)."},{"ko":"2워드 프리셋(400001~400006)은 매뉴얼 표에 03/06/16 이 적혀 있지만 06 은 한 워드만 쓰므로 여기선 03·16 만 적었다.","en":"The 2-word presets (400001-400006) list 03/06/16, but 06 writes one word only, so only 03/16 are listed here."},{"ko":"PLC·그래픽 패널과 연결할 때는 FC16 보다 FC06 을 권장(p.18).","en":"FC06 is recommended over FC16 for PLCs/graphic panels (p.18)."},{"ko":"타이머 그룹(400101~400110)의 시간 범위·출력 모드 코드는 자리수(4·6)에 따라 다르다 — 여기선 C-T 만 넣었다 (p.26).","en":"Timer group (400101-400110) time range/output mode codes depend on 4/6-digit type; only C-T is included (p.26)."}],"sources":[{"title":"User Manual for Communication Counters/Timers CT Series MCC-CTC1-V1.3-EN","publisher":"Autonics","edition":{"ko":"MCC-CTC1-V1.3-EN (2025-08-05)","en":"MCC-CTC1-V1.3-EN (2025-08-05)"},"url":"https://www.autonics.com/glb/common/download/517949","pages":{"ko":"pp.21-27 매핑 표 (인쇄 쪽 = PDF 쪽)","en":"pp.21-27 mapping table (printed page = PDF page)"},"checked":"2026-10-22"},{"title":"Counters / Timers CT Series PRODUCT MANUAL TCD220014AC","publisher":"Autonics","edition":{"ko":"CT_EN_TCD220014AC_20240228","en":"CT_EN_TCD220014AC_20240228"},"url":"https://www.autonics.com/glb/common/download/506384","pages":{"ko":"p.2 주문 정보, 사양 «Communication Interface», 통신 파라미터 표","en":"p.2 ordering information, 'Communication Interface' spec, communication parameter table"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/kn-2000w","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"KN-2000W","models":["KN-2□4□W","KN-2□5□W"],"kind":"panel-meter","title":{"ko":"오토닉스 KN-2000W 1채널 디지털 온도 지시계 (통신 출력 모델)","en":"Autonics KN-2000W 1-channel digital temperature indicator (communication models)"},"summary":{"ko":"열전대·RTD·아날로그 입력 지시계. 옵션 출력 4(통신)·5(PV 전송+통신) 모델이 RS485 Modbus RTU. 입력 접점(경보·단위 표시등), 입력 레지스터(현재값·소수점·상태), 보유 레지스터(입력·스케일·경보·통신 설정)를 담았다.","en":"Thermocouple/RTD/analog indicator; option output 4 (communication) and 5 (PV transmission + communication) models have RS485 Modbus RTU. Covers discrete inputs (alarm/unit indicators), input registers (PV, decimal point, status) and holding registers (input, scale, alarm, comm settings)."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[1200,2400,4800,9600,19200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,99],"notes":[{"ko":"통신 사양(p.2 «Communication Interface»): Modbus RTU, 최대 31대, 9600 bps 기본, 데이터 8비트·패리티 없음·정지 1비트 고정. 국번 파라미터 2-29 Adrr 기본 01, 범위 01~99 (p.4).","en":"Comm spec (p.2): Modbus RTU, up to 31 units, 9600 bps default, 8 data bits, no parity, 1 stop bit (fixed). Address parameter 2-29 Adrr default 01, range 01-99 (p.4)."},{"ko":"매뉴얼은 «400001 (0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(p.4). 프레임 예시는 없다.","en":"Manual writes «400001 (0000)»: 1-based reference plus hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (p.4). No frame example is given."},{"ko":"함수 코드: 입력 접점 02, 입력 레지스터 04, 보유 레지스터 03·06·16 (p.4).","en":"Function codes: discrete inputs 02, input registers 04, holding registers 03/06/16 (p.4)."}]},"registers":[{"table":"discrete-inputs","address":0,"manualAddress":"100001 (0000)","type":"bit","name":{"ko":"AL1 표시등","en":"AL1 indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"discrete-inputs","address":1,"manualAddress":"100002 (0001)","type":"bit","name":{"ko":"AL2 표시등","en":"AL2 indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"discrete-inputs","address":2,"manualAddress":"100003 (0002)","type":"bit","name":{"ko":"AL3 표시등","en":"AL3 indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"discrete-inputs","address":3,"manualAddress":"100004 (0003)","type":"bit","name":{"ko":"AL4 표시등","en":"AL4 indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"discrete-inputs","address":4,"manualAddress":"100005 (0004)","type":"bit","name":{"ko":"℉ 표시등","en":"°F indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"discrete-inputs","address":5,"manualAddress":"100006 (0005)","type":"bit","name":{"ko":"℃ 표시등","en":"°C indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"discrete-inputs","address":6,"manualAddress":"100007 (0006)","type":"bit","name":{"ko":"% 표시등","en":"% indicator"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"input-registers","address":0,"manualAddress":"300001 (0000)","type":"s16","name":{"ko":"현재값","en":"Present value"},"access":"r","fc":[4],"range":{"min":-19999,"max":19999},"description":{"ko":"소수점 위치는 300003 을 따른다.","en":"Decimal point per 300003."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"input-registers","address":1,"manualAddress":"300002 (0001)","type":"u16","name":{"ko":"입력 사양","en":"Input specification"},"access":"r","fc":[4],"description":{"ko":"코드표는 매뉴얼 «Input specification parameter setting/output value» 참조.","en":"See the manual's input specification code table."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"input-registers","address":2,"manualAddress":"300003 (0002)","type":"u16","name":{"ko":"소수점 위치","en":"Decimal point"},"access":"r","fc":[4],"values":[{"value":4,"ko":".0000","en":".0000"},{"value":3,"ko":"0.000","en":"0.000"},{"value":2,"ko":"0.00","en":"0.00"},{"value":1,"ko":"0.0","en":"0.0"},{"value":0,"ko":"0","en":"0"}],"description":{"ko":"아날로그 입력일 때(2-1 입력 사양: Analog)","en":"For analog input (2-1 input specification: analog)"},"ref":"p.4 «Communication Parameter Setting»"},{"table":"input-registers","address":3,"manualAddress":"300004 (0003)","type":"u16","name":{"ko":"PWM 출력","en":"PWM OUT"},"access":"r","fc":[4],"range":{"min":0,"max":20000},"ref":"p.4 «Communication Parameter Setting»"},{"table":"input-registers","address":4,"manualAddress":"300005 (0004)","type":"u16","name":{"ko":"표시·경보 상태 비트","en":"Indicator / alarm status bits"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"AL1 표시등","en":"AL1 indicator"},{"bit":1,"ko":"AL2 표시등","en":"AL2 indicator"},{"bit":2,"ko":"AL3 표시등","en":"AL3 indicator"},{"bit":3,"ko":"AL4 표시등","en":"AL4 indicator"},{"bit":4,"ko":"℉ 표시등","en":"°F indicator"},{"bit":5,"ko":"℃ 표시등","en":"°C indicator"},{"bit":6,"ko":"% 표시등","en":"% indicator"}],"description":{"ko":"표는 위에서부터 X(MSB)·%·℃·℉·AL4·AL3·AL2·AL1(LSB) 순서 — 최하위 비트를 AL1 로 놓고 차례로 매겼다.","en":"Table lists X (MSB), %, °C, °F, AL4, AL3, AL2, AL1 (LSB); bits numbered from AL1 at the LSB."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":0,"manualAddress":"400001 (0000)","type":"u16","name":{"ko":"입력 사양","en":"Input specification"},"access":"rw","fc":[3,6,16],"description":{"ko":"설정 범위는 프로그램 모드의 같은 파라미터와 같다(p.4).","en":"Same setting range as the program-mode parameter (p.4)."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":1,"manualAddress":"400002 (0001)","type":"u16","name":{"ko":"온도 단위","en":"Temperature unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":2,"manualAddress":"400003 (0002)","type":"u16","name":{"ko":"표시 단위","en":"Display unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"},{"value":2,"ko":"%","en":"%"},{"value":3,"ko":"없음(OFF)","en":"OFF"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":3,"manualAddress":"400004 (0003)","type":"s16","name":{"ko":"입력 상한","en":"High limit input"},"access":"rw","fc":[3,6,16],"description":{"ko":"설정 범위는 프로그램 모드의 같은 파라미터와 같다(p.4).","en":"Same setting range as the program-mode parameter (p.4)."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":4,"manualAddress":"400005 (0004)","type":"s16","name":{"ko":"입력 하한","en":"Low limit input"},"access":"rw","fc":[3,6,16],"description":{"ko":"설정 범위는 프로그램 모드의 같은 파라미터와 같다(p.4).","en":"Same setting range as the program-mode parameter (p.4)."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":5,"manualAddress":"400006 (0005)","type":"s16","name":{"ko":"스케일 상한","en":"High limit scale"},"access":"rw","fc":[3,6,16],"range":{"min":-19999,"max":19999},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":6,"manualAddress":"400007 (0006)","type":"s16","name":{"ko":"스케일 하한","en":"Low limit scale"},"access":"rw","fc":[3,6,16],"range":{"min":-19999,"max":19999},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":7,"manualAddress":"400008 (0007)","type":"s16","name":{"ko":"입력 보정","en":"Input correction"},"access":"rw","fc":[3,6,16],"range":{"min":-999,"max":999},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":8,"manualAddress":"400009 (0008)","type":"u16","name":{"ko":"입력 디지털 필터","en":"Input digital filter"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":16},"description":{"ko":"01 = OFF","en":"01 = OFF"},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":9,"manualAddress":"400010 (0009)","type":"u16","name":{"ko":"AL1 경보 동작","en":"AL1 alarm operation"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"절대값 상한 경보","en":"Absolute high limit alarm"},{"value":2,"ko":"절대값 하한 경보","en":"Absolute low limit alarm"},{"value":3,"ko":"센서 단선 경보","en":"Sensor break alarm"},{"value":4,"ko":"경보 없음","en":"No alarm"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":10,"manualAddress":"400011 (000A)","type":"u16","name":{"ko":"AL2 경보 동작","en":"AL2 alarm operation"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"절대값 상한 경보","en":"Absolute high limit alarm"},{"value":2,"ko":"절대값 하한 경보","en":"Absolute low limit alarm"},{"value":3,"ko":"센서 단선 경보","en":"Sensor break alarm"},{"value":4,"ko":"경보 없음","en":"No alarm"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":11,"manualAddress":"400012 (000B)","type":"u16","name":{"ko":"AL3 경보 동작","en":"AL3 alarm operation"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"절대값 상한 경보","en":"Absolute high limit alarm"},{"value":2,"ko":"절대값 하한 경보","en":"Absolute low limit alarm"},{"value":3,"ko":"센서 단선 경보","en":"Sensor break alarm"},{"value":4,"ko":"경보 없음","en":"No alarm"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":12,"manualAddress":"400013 (000C)","type":"u16","name":{"ko":"AL4 경보 동작","en":"AL4 alarm operation"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"절대값 상한 경보","en":"Absolute high limit alarm"},{"value":2,"ko":"절대값 하한 경보","en":"Absolute low limit alarm"},{"value":3,"ko":"센서 단선 경보","en":"Sensor break alarm"},{"value":4,"ko":"경보 없음","en":"No alarm"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":13,"manualAddress":"400014 (000D)","type":"u16","name":{"ko":"AL1 경보 옵션","en":"AL1 alarm option"},"access":"rw","fc":[3,6,16],"values":[{"value":10,"ko":"표준 경보","en":"Standard alarm"},{"value":11,"ko":"경보 래치","en":"Alarm latch"},{"value":12,"ko":"대기 시퀀스","en":"Standby sequence"},{"value":13,"ko":"경보 래치+대기 시퀀스","en":"Alarm latch and standby sequence"},{"value":14,"ko":"경보 없음(설정 불가)","en":"No alarm (not settable)"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":14,"manualAddress":"400015 (000E)","type":"u16","name":{"ko":"AL2 경보 옵션","en":"AL2 alarm option"},"access":"rw","fc":[3,6,16],"values":[{"value":10,"ko":"표준 경보","en":"Standard alarm"},{"value":11,"ko":"경보 래치","en":"Alarm latch"},{"value":12,"ko":"대기 시퀀스","en":"Standby sequence"},{"value":13,"ko":"경보 래치+대기 시퀀스","en":"Alarm latch and standby sequence"},{"value":14,"ko":"경보 없음(설정 불가)","en":"No alarm (not settable)"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":15,"manualAddress":"400016 (000F)","type":"u16","name":{"ko":"AL3 경보 옵션","en":"AL3 alarm option"},"access":"rw","fc":[3,6,16],"values":[{"value":10,"ko":"표준 경보","en":"Standard alarm"},{"value":11,"ko":"경보 래치","en":"Alarm latch"},{"value":12,"ko":"대기 시퀀스","en":"Standby sequence"},{"value":13,"ko":"경보 래치+대기 시퀀스","en":"Alarm latch and standby sequence"},{"value":14,"ko":"경보 없음(설정 불가)","en":"No alarm (not settable)"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":16,"manualAddress":"400017 (0010)","type":"u16","name":{"ko":"AL4 경보 옵션","en":"AL4 alarm option"},"access":"rw","fc":[3,6,16],"values":[{"value":10,"ko":"표준 경보","en":"Standard alarm"},{"value":11,"ko":"경보 래치","en":"Alarm latch"},{"value":12,"ko":"대기 시퀀스","en":"Standby sequence"},{"value":13,"ko":"경보 래치+대기 시퀀스","en":"Alarm latch and standby sequence"},{"value":14,"ko":"경보 없음(설정 불가)","en":"No alarm (not settable)"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":17,"manualAddress":"400018 (0011)","type":"u16","name":{"ko":"경보 출력 히스테리시스","en":"Alarm output hysteresis"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":999},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":18,"manualAddress":"400019 (0012)","type":"s16","name":{"ko":"20 mA 출력 스케일","en":"20 mA output scale"},"access":"rw","fc":[3,6,16],"description":{"ko":"설정 범위는 프로그램 모드의 같은 파라미터와 같다(p.4).","en":"Same setting range as the program-mode parameter (p.4)."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":19,"manualAddress":"400020 (0013)","type":"s16","name":{"ko":"4 mA 출력 스케일","en":"4 mA output scale"},"access":"rw","fc":[3,6,16],"description":{"ko":"설정 범위는 프로그램 모드의 같은 파라미터와 같다(p.4).","en":"Same setting range as the program-mode parameter (p.4)."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":20,"manualAddress":"400021 (0014)","type":"u16","name":{"ko":"소수점 위치","en":"Decimal point"},"access":"rw","fc":[3,6,16],"values":[{"value":4,"ko":".0000","en":".0000"},{"value":3,"ko":"0.000","en":"0.000"},{"value":2,"ko":"0.00","en":"0.00"},{"value":1,"ko":"0.0","en":"0.0"},{"value":0,"ko":"0","en":"0"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":21,"manualAddress":"400022 (0015)","type":"u16","name":{"ko":"입력·전송 출력 확장","en":"Input and transmission output extension"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0%","en":"0%"},{"value":1,"ko":"5%","en":"5%"},{"value":2,"ko":"10%","en":"10%"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":22,"manualAddress":"400023 (0016)","type":"u16","name":{"ko":"디지털 입력 단자 기능","en":"Digital input terminal"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"경보 리셋","en":"Alarm reset"},{"value":1,"ko":"홀드","en":"Hold"},{"value":2,"ko":"영점 조정","en":"Zero-point adjustment"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":23,"manualAddress":"400024 (0017)","type":"u16","name":{"ko":"디지털 입력 키 기능","en":"Digital input key"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"경보 리셋","en":"Alarm reset"},{"value":1,"ko":"홀드","en":"Hold"},{"value":2,"ko":"영점 조정","en":"Zero-point adjustment"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":24,"manualAddress":"400025 (0018)","type":"u16","name":{"ko":"입력 특수 기능","en":"Input special function"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"선형","en":"Linear"},{"value":1,"ko":"제곱근","en":"Root"},{"value":2,"ko":"제곱","en":"Square"},{"value":3,"ko":"2단 함수","en":"Two unit function"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":25,"manualAddress":"400026 (0019)","type":"u16","name":{"ko":"센서 단선 경보 출력","en":"Sensor break alarm output"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"ON","en":"ON"},{"value":1,"ko":"OFF","en":"OFF"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":26,"manualAddress":"400027 (001A)","type":"u16","name":{"ko":"잠금","en":"Lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"LOCK1","en":"LOCK1"},{"value":2,"ko":"LOCK2","en":"LOCK2"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":27,"manualAddress":"400028 (001B)","type":"u16","name":{"ko":"표시 색","en":"Display color"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"빨강","en":"Red"},{"value":1,"ko":"초록","en":"Green"},{"value":2,"ko":"노랑","en":"Yellow"},{"value":3,"ko":"빨강-초록","en":"Red-Green"},{"value":4,"ko":"초록-빨강","en":"Green-Red"}],"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":32,"manualAddress":"400033 (0020)","type":"u16","name":{"ko":"통신 국번","en":"Comm. address"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":99},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":33,"manualAddress":"400034 (0021)","type":"u16","name":{"ko":"통신 속도","en":"Comm. speed"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"19200 bps","en":"19200 bps"},{"value":1,"ko":"9600 bps","en":"9600 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"2400 bps","en":"2400 bps"},{"value":4,"ko":"1200 bps","en":"1200 bps"}],"description":{"ko":"매뉴얼 표기 «0: 192000» 은 통신 사양표(1,200~19,200 bps)로 보아 19200 의 오기로 보고 19200 으로 적었다.","en":"The manual prints '0: 192000'; given the spec table (1,200-19,200 bps) it is read as 19200."},"ref":"p.4 «Communication Parameter Setting»"},{"table":"holding-registers","address":34,"manualAddress":"400035 (0022)","type":"u16","name":{"ko":"통신 쓰기","en":"Comm. write"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"금지","en":"Disable"},{"value":1,"ko":"허용","en":"Enable"}],"ref":"p.4 «Communication Parameter Setting»"}],"notes":[{"ko":"RS485 는 옵션 출력 코드 4(통신)·5(PV 전송+통신) 모델만(p.2 주문 정보). models 의 첫 □ 는 경보 출력(0·2·4), 둘째 □ 는 전원(0: 100-240 VAC, 1: 24 VDC).","en":"RS485 only on option output code 4 (communication) and 5 (PV transmission + communication) (p.2). First □ = alarm outputs (0/2/4), second □ = power (0: 100-240 VAC, 1: 24 VDC)."},{"ko":"보유 레지스터 400029~400032(001C~001F)는 AL1~AL4 표시 색(0 빨강, 1 초록, 2 노랑) (p.4).","en":"Holding 400029-400032 (001C-001F) are AL1-AL4 display colors (0 red, 1 green, 2 yellow) (p.4)."},{"ko":"각 보유 레지스터는 프로그램 모드 파라미터와 같은 조건에서만 유효하다(예: 스케일은 아날로그 입력일 때) (p.4).","en":"Each holding register is valid under the same conditions as its program-mode parameter (e.g. scale only for analog input) (p.4)."}],"sources":[{"title":"1-Channel Digital Temperature Indicators KN-2000W Series PRODUCT MANUAL TCD210154AH","publisher":"Autonics","edition":{"ko":"KN-2000W_EN_TCD210154AH_20260515 (PDF 작성 2026-05-15)","en":"KN-2000W_EN_TCD210154AH_20260515 (PDF created 2026-05-15)"},"url":"https://www.autonics.com/glb/common/download/525039","pages":{"ko":"p.2 주문 정보·통신 사양, p.4 프로그램 모드·통신 파라미터 표","en":"p.2 ordering and comm spec, p.4 program mode and communication parameter tables"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/mt4n","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"MT4N","models":["MT4N-DV-□4","MT4N-DA-□4","MT4N-AV-□4","MT4N-AA-□4"],"kind":"panel-meter","title":{"ko":"오토닉스 MT4N 4자리 멀티 패널 미터 (RS485 모델)","en":"Autonics MT4N 4-digit multi panel meter (RS485 models)"},"summary":{"ko":"DC/AC 전압·전류 패널 미터(LCD). 출력 코드 4(릴레이 OUT1 + RS485) 모델이 Modbus RTU. 측정값·소수점·피크, OUT1 상태, 설정(프리셋·입력·통신)을 담았다.","en":"DC/AC voltage/current panel meter (LCD). Output code 4 (relay OUT1 + RS485) models have Modbus RTU. Covers measured value, decimal point, peaks, OUT1 status and settings (preset, input, comm)."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,99],"notes":[{"ko":"통신 기본값: 통신 매뉴얼 «3.2 MT4N» 공장 기본(인쇄 p.32 = PDF p.33): 국번 01, 9600, NONE, 정지 2, 응답 대기 5 ms. 데이터 8비트 고정·지원 속도·최대 31대(국번 01~99)는 제품 매뉴얼 TCD210231AI p.3 «Communication Interface».","en":"Defaults from comm manual 3.2 MT4N (printed p.32 = PDF p.33): addr 01, 9600, NONE, stop 2, wait 5 ms. 8 data bits, speeds and max 31 units (address 01-99) from product manual TCD210231AI p.3."},{"ko":"매뉴얼은 «300001(0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(인쇄 pp.27-29). 1.1 절 프레임 예시는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «300001(0000)»: 1-based reference + hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (printed pp.27-29). Frame examples show layout only."},{"ko":"브로드캐스트 명령을 지원하지 않는다(통신 매뉴얼 «Communication Protocol», PDF p.6).","en":"Broadcast is not supported (comm manual, PDF p.6)."}]},"registers":[{"table":"input-registers","address":0,"manualAddress":"300001(0000)","type":"s16","name":{"ko":"측정값","en":"Measured value"},"access":"r","fc":[4],"values":[{"value":30000,"ko":"HHHH","en":"HHHH"},{"value":-30000,"ko":"LLLL","en":"LLLL"},{"value":30001,"ko":"d-HH","en":"d-HH"},{"value":-30001,"ko":"d-LL","en":"d-LL"},{"value":30002,"ko":"F-HH","en":"F-HH"}],"description":{"ko":"STND 는 -5~110 %, SCAL 은 -1999~9999 표시. 정수로 온다 — 소수점 위치는 300002(0001).","en":"STND shows -5 to 110 %, SCAL -1999 to 9999. Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":1,"manualAddress":"300002(0001)","type":"u16","name":{"ko":"소수점 위치·표시 모드","en":"Decimal point / display mode"},"access":"r","fc":[4],"description":{"ko":"상위 바이트 = 모드(0 STND·1 SCAL·2 FREQ), 하위 바이트 = 소수점 자리 수(0~3). 예: SCAL 0.00 → 0102H.","en":"High byte = mode (0 STND, 1 SCAL, 2 FREQ), low byte = decimal places (0-3). E.g. SCAL 0.00 → 0102H."},"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":2,"manualAddress":"300003(0002)","type":"s16","name":{"ko":"최고 피크값","en":"HI peak value"},"access":"r","fc":[4],"description":{"ko":"정수로 온다 — 소수점 위치는 300002(0001).","en":"Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":3,"manualAddress":"300004(0003)","type":"s16","name":{"ko":"최저 피크값","en":"LO peak value"},"access":"r","fc":[4],"description":{"ko":"정수로 온다 — 소수점 위치는 300002(0001).","en":"Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":4,"manualAddress":"300005(0004)","type":"u16","name":{"ko":"OUT1 상태","en":"OUT status"},"access":"r","fc":[4],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":100,"manualAddress":"300101(0064)","type":"u16","name":{"ko":"제품 번호 H","en":"Product number H"},"access":"r","fc":[4],"description":{"ko":"0672H","en":"0672H"},"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":101,"manualAddress":"300102(0065)","type":"u16","name":{"ko":"제품 번호 L","en":"Product number L"},"access":"r","fc":[4],"values":[{"value":45660,"ko":"DV","en":"DV"},{"value":45760,"ko":"DA","en":"DA"},{"value":45860,"ko":"AV","en":"AV"},{"value":45960,"ko":"AA","en":"AA"}],"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"input-registers","address":103,"manualAddress":"300104(0067)","type":"u16","name":{"ko":"소프트웨어 버전","en":"Software version"},"access":"r","fc":[4],"ref":"인쇄 p.27 표 2.3.1 (PDF p.28)"},{"table":"discrete-inputs","address":0,"manualAddress":"100001(0000)","type":"bit","name":{"ko":"OUT1 출력 상태","en":"Out status OUT1"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.28 표 2.3.2 (PDF p.29)"},{"table":"holding-registers","address":0,"manualAddress":"400001(0000)","type":"s16","name":{"ko":"OUT1 상한 프리셋","en":"OUT1 high preset"},"access":"rw","fc":[3,6,16],"description":{"ko":"정수로 온다 — 소수점 위치는 300002(0001).","en":"Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.28 표 2.3.3.1 (PDF p.29)"},{"table":"holding-registers","address":1,"manualAddress":"400002(0001)","type":"s16","name":{"ko":"OUT1 하한 프리셋","en":"OUT1 low preset"},"access":"rw","fc":[3,6,16],"description":{"ko":"정수로 온다 — 소수점 위치는 300002(0001).","en":"Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.28 표 2.3.3.1 (PDF p.29)"},{"table":"holding-registers","address":4,"manualAddress":"400005(0004)","type":"s16","name":{"ko":"최고 피크","en":"High peak"},"access":"rw","fc":[3,6,16],"description":{"ko":"공장 기본 0. 정수로 온다 — 소수점 위치는 300002(0001).","en":"Factory default 0. Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.28 표 2.3.3.1 (PDF p.29)"},{"table":"holding-registers","address":5,"manualAddress":"400006(0005)","type":"s16","name":{"ko":"최저 피크","en":"Low peak"},"access":"rw","fc":[3,6,16],"description":{"ko":"공장 기본 0. 정수로 온다 — 소수점 위치는 300002(0001).","en":"Factory default 0. Sent as an integer; decimal point position in 300002(0001)."},"ref":"인쇄 p.28 표 2.3.3.1 (PDF p.29)"},{"table":"holding-registers","address":100,"manualAddress":"400101(0064)","type":"u16","name":{"ko":"입력 레인지","en":"Input range"},"access":"rw","fc":[3,6,16],"description":{"ko":"코드표는 측정 입력 사양 참조라고만 적혀 있다.","en":"Only refers to the measurement input specification for codes."},"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":101,"manualAddress":"400102(0065)","type":"u16","name":{"ko":"표시 모드","en":"Display"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"STND","en":"STND"},{"value":1,"ko":"SCAL","en":"SCAL"},{"value":2,"ko":"FREQ","en":"FREQ"}],"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":102,"manualAddress":"400103(0066)","type":"u16","name":{"ko":"소수점","en":"Dot"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":3},"description":{"ko":"0~3. 매뉴얼 값 이름이 7세그 기호(«)000»…«0»)로만 적혀 자리 뜻은 확정하지 않았다.","en":"0-3; value names are 7-segment symbols only, so digit meaning is not asserted."},"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":103,"manualAddress":"400104(0067)","type":"s16","name":{"ko":"스케일 상한","en":"High scale"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":104,"manualAddress":"400105(0068)","type":"s16","name":{"ko":"스케일 하한","en":"Low scale"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":105,"manualAddress":"400106(0069)","type":"u16","name":{"ko":"측정 방식 (AC 입력)","en":"Input type (AC models)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"T.RMS","en":"T.RMS"},{"value":1,"ko":"A.RMS","en":"A.RMS"},{"value":2,"ko":"AVG","en":"AVG"}],"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":106,"manualAddress":"400107(006A)","type":"u16","name":{"ko":"단위 표시등","en":"Display unit lamp"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"UNIT","en":"UNIT"},{"value":1,"ko":"mV","en":"mV"},{"value":2,"ko":"V","en":"V"},{"value":3,"ko":"mA","en":"mA"},{"value":4,"ko":"A","en":"A"},{"value":5,"ko":"Hz","en":"Hz"},{"value":6,"ko":"OFF","en":"OFF"}],"ref":"인쇄 p.28 표 2.3.3.2 (PDF p.29)"},{"table":"holding-registers","address":200,"manualAddress":"400201(00C8)","type":"u16","name":{"ko":"OUT1 동작","en":"OUT1 type"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"HI","en":"HI"},{"value":2,"ko":"LO","en":"LO"},{"value":3,"ko":"HL","en":"HL"},{"value":4,"ko":"HL-G","en":"HL-G"}],"ref":"인쇄 p.28 표 2.3.3.3 (PDF p.29)"},{"table":"holding-registers","address":206,"manualAddress":"400207(00CE)","type":"u16","name":{"ko":"표시 주기","en":"Display time"},"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 0.1~5.0 초. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.1-5.0 s; raw scaling not stated."},"ref":"인쇄 p.28 표 2.3.3.3 (PDF p.29)"},{"table":"holding-registers","address":207,"manualAddress":"400208(00CF)","type":"u16","name":{"ko":"표시 색","en":"Color"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"빨강","en":"RED"},{"value":1,"ko":"초록","en":"GRN"},{"value":2,"ko":"노랑","en":"YEL"},{"value":3,"ko":"빨강-초록","en":"R-G"},{"value":4,"ko":"초록-빨강","en":"G-R"}],"ref":"인쇄 p.28 표 2.3.3.3 (PDF p.29)"},{"table":"holding-registers","address":208,"manualAddress":"400209(00D0)","type":"u16","name":{"ko":"전면 영점 키","en":"Zero key"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"NO","en":"NO"},{"value":1,"ko":"YES","en":"YES"}],"ref":"인쇄 p.28 표 2.3.3.3 (PDF p.29)"},{"table":"holding-registers","address":209,"manualAddress":"400210(00D1)","type":"u16","name":{"ko":"외부 입력 단자 기능","en":"Event input"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"HOLD","en":"HOLD"},{"value":1,"ko":"ZERO","en":"ZERO"}],"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"},{"table":"holding-registers","address":212,"manualAddress":"400213(00D4)","type":"u16","name":{"ko":"통신 국번","en":"Address"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":99},"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"},{"table":"holding-registers","address":213,"manualAddress":"400214(00D5)","type":"u16","name":{"ko":"통신 속도","en":"Bit per second"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200 bps","en":"1200 bps"},{"value":1,"ko":"2400 bps","en":"2400 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"9600 bps","en":"9600 bps"},{"value":4,"ko":"19200 bps","en":"19200 bps"},{"value":5,"ko":"38400 bps","en":"38400 bps"}],"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"},{"table":"holding-registers","address":214,"manualAddress":"400215(00D6)","type":"u16","name":{"ko":"패리티","en":"Parity bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"},{"table":"holding-registers","address":215,"manualAddress":"400216(00D7)","type":"u16","name":{"ko":"정지 비트","en":"Stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"},{"table":"holding-registers","address":216,"manualAddress":"400217(00D8)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response waiting time"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"},{"table":"holding-registers","address":217,"manualAddress":"400218(00D9)","type":"u16","name":{"ko":"잠금","en":"Lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"LOC1","en":"LOC1"},{"value":2,"ko":"LOC2","en":"LOC2"},{"value":3,"ko":"LOC3","en":"LOC3"}],"ref":"인쇄 p.29 표 2.3.3.3 (PDF p.30)"}],"notes":[{"ko":"RS485 는 출력 코드 4(릴레이 OUT1 + RS485 통신) 모델만(제품 매뉴얼 p.2 주문 정보). models 의 □ 는 전원 코드(E: 12-24 VDC/VAC, 4: 100-240 VAC).","en":"RS485 only on output code 4 (relay OUT1 + RS485) (product manual p.2). □ = power code (E: 12-24 VDC/VAC, 4: 100-240 VAC)."},{"ko":"OUT2 프리셋(400003·400004)·OUT2 동작·OUT2 히스테리시스는 표에 있으나 «Unable to set» 등 RS485 모델(OUT1 만)과 맞지 않아 넣지 않았다.","en":"OUT2 preset/type/hysteresis are listed but marked 'Unable to set' or don't apply to the RS485 model (OUT1 only), so they are omitted."},{"ko":"같은 통신 매뉴얼의 MT4W·MT4Y 표는 보유 레지스터 주소가 다르다 — 이 파일은 MT4N 전용. 쪽 번호: 인쇄 쪽 = PDF 쪽 - 1.","en":"MT4W/MT4Y tables in the same manual use different holding addresses; this file is MT4N only. Printed page = PDF page - 1."}],"sources":[{"title":"User Manual for Communication 4-Digit Multi Panel Meters MT Series MCT-MTC1-V1.7-EN","publisher":"Autonics","edition":{"ko":"MCT-MTC1-V1.7-EN (2024-11-26)","en":"MCT-MTC1-V1.7-EN (2024-11-26)"},"url":"https://www.autonics.com/glb/common/download/510417","pages":{"ko":"인쇄 pp.27-29 (PDF pp.28-30) MT4N 매핑 표, 인쇄 p.32 (PDF p.33) 공장 기본값","en":"printed pp.27-29 (PDF pp.28-30) MT4N mapping table, printed p.32 (PDF p.33) factory defaults"},"checked":"2026-10-22"},{"title":"4-Digit Multi Panel Meters MT4N Series PRODUCT MANUAL TCD210231AI","publisher":"Autonics","edition":{"ko":"MT4N_EN_TCD210231AI_20260402","en":"MT4N_EN_TCD210231AI_20260402"},"url":"https://www.autonics.com/glb/common/download/524327","pages":{"ko":"p.2 주문 정보, p.3 Communication Interface","en":"p.2 ordering information, p.3 Communication Interface"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/mt4w","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"MT4W","models":["MT4W-DV-□8","MT4W-DV-□9","MT4W-DA-□8","MT4W-DA-□9","MT4W-AV-□8","MT4W-AV-□9","MT4W-AA-□8","MT4W-AA-□9"],"kind":"panel-meter","title":{"ko":"오토닉스 MT4W 4자리 멀티 패널 미터 (RS485 모델)","en":"Autonics MT4W 4-digit multi panel meter (RS485 models)"},"summary":{"ko":"DC/AC 전압·전류 패널 미터. 출력 코드 8·9 모델만 RS485 Modbus RTU. 측정값·소수점·피크, 비교 출력 상태, 설정(프리셋·입력·통신)을 담았다.","en":"DC/AC voltage/current panel meter. Only output code 8/9 models have RS485 Modbus RTU. Covers measured value, decimal, peaks, comparator outputs and settings."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,99],"notes":[{"ko":"통신 기본값: 통신 매뉴얼 «3.1.3 Parameter 2 group» 공장 기본(인쇄 p.31 = PDF p.32): 국번 01, 9600, NONE, 정지 2, 응답 대기 5 ms. 데이터 8비트 고정·지원 속도는 제품 매뉴얼 TCD220015AI p.3 «Communication Interface».","en":"Defaults from comm manual factory-default table (printed p.31 = PDF p.32): addr 01, 9600, NONE, stop 2, wait 5 ms. 8 data bits and speeds from product manual TCD220015AI p.3."},{"ko":"매뉴얼은 «300001(0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(인쇄 pp.21-23). 프레임 예시(1.1 절)는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «300001(0000)»: 1-based reference + hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (printed pp.21-23). Frame examples show layout only."},{"ko":"브로드캐스트 명령을 지원하지 않는다(통신 매뉴얼 «Communication Protocol», PDF p.6).","en":"Broadcast is not supported (comm manual, PDF p.6)."}]},"registers":[{"table":"input-registers","address":0,"manualAddress":"300001(0000)","type":"s16","name":{"ko":"측정값","en":"Measured value"},"access":"r","fc":[4],"values":[{"value":30000,"ko":"HHHH(STND 상한 초과)","en":"HHHH (STND over)"},{"value":-30000,"ko":"LLLL(STND 하한 미만)","en":"LLLL (STND under)"},{"value":30001,"ko":"d-HH(SCAL 상한 초과)","en":"d-HH (SCAL over)"},{"value":-30001,"ko":"d-LL(SCAL 하한 미만)","en":"d-LL (SCAL under)"},{"value":30002,"ko":"F-HH(FREQ 초과)","en":"F-HH (FREQ over)"}],"description":{"ko":"소수점 없는 정수로 온다 — 소수점 위치는 300002(0001). STND 는 -5~110 %, SCAL 은 -1999~9999 표시.","en":"Integer without decimal point — position in 300002(0001). STND shows -5..110 %, SCAL -1999..9999."},"ref":"인쇄 p.21 표 2.1.1 (PDF p.22)","source":0},{"table":"input-registers","address":1,"manualAddress":"300002(0001)","type":"u16","name":{"ko":"소수점 위치·표시 모드","en":"Decimal point / display mode"},"access":"r","fc":[4],"values":[{"value":0,"ko":"STND 0","en":"STND 0"},{"value":1,"ko":"STND 0.0","en":"STND 0.0"},{"value":2,"ko":"STND 0.00","en":"STND 0.00"},{"value":3,"ko":"STND 0.000","en":"STND 0.000"},{"value":256,"ko":"SCAL 0 (0x0100)","en":"SCAL 0 (0x0100)"},{"value":257,"ko":"SCAL 0.0 (0x0101)","en":"SCAL 0.0 (0x0101)"},{"value":258,"ko":"SCAL 0.00 (0x0102)","en":"SCAL 0.00 (0x0102)"},{"value":259,"ko":"SCAL 0.000 (0x0103)","en":"SCAL 0.000 (0x0103)"},{"value":512,"ko":"FREQ 0 (0x0200)","en":"FREQ 0 (0x0200)"},{"value":513,"ko":"FREQ 0.0 (0x0201)","en":"FREQ 0.0 (0x0201)"},{"value":514,"ko":"FREQ 0.00 (0x0202)","en":"FREQ 0.00 (0x0202)"},{"value":515,"ko":"FREQ 0.000 (0x0203)","en":"FREQ 0.000 (0x0203)"}],"description":{"ko":"상위 바이트 = 모드(0 STND·1 SCAL·2 FREQ), 하위 바이트 = 소수점 자리 수.","en":"High byte = mode (0 STND, 1 SCAL, 2 FREQ), low byte = decimal places."},"ref":"인쇄 p.21 표 2.1.1","source":0},{"table":"input-registers","address":2,"manualAddress":"300003(0002)","type":"s16","name":{"ko":"최고 피크값","en":"HI peak value"},"access":"r","fc":[4],"description":{"ko":"입력 최대값. 소수점 위치는 300002.","en":"Max of input. Decimal per 300002."},"ref":"인쇄 p.21 표 2.1.1","source":0},{"table":"input-registers","address":3,"manualAddress":"300004(0003)","type":"s16","name":{"ko":"최저 피크값","en":"LO peak value"},"access":"r","fc":[4],"description":{"ko":"입력 최소값. 소수점 위치는 300002.","en":"Min of input. Decimal per 300002."},"ref":"인쇄 p.21 표 2.1.1","source":0},{"table":"input-registers","address":4,"manualAddress":"300005(0004)","type":"u16","name":{"ko":"출력 상태 (HI·GO·LO)","en":"OUT status (HI, GO, LO)"},"access":"r","fc":[4],"description":{"ko":"HI·GO·LO 출력 상태(0 OFF / 1 ON). 매뉴얼에 비트 자리가 적혀 있지 않아 bits 를 넣지 않았다 — 입력 접점 100001~100003 을 쓰면 확실하다.","en":"HI/GO/LO states (0 OFF/1 ON). Bit positions not given in manual — use discrete inputs 100001-100003 instead."},"ref":"인쇄 p.21 표 2.1.1","source":0},{"table":"discrete-inputs","address":0,"manualAddress":"100001(0000)","type":"bit","name":{"ko":"LO 출력 상태","en":"OUT status LO"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.22 표 2.1.2","source":0},{"table":"discrete-inputs","address":1,"manualAddress":"100002(0001)","type":"bit","name":{"ko":"GO 출력 상태","en":"OUT status GO"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.22 표 2.1.2","source":0},{"table":"discrete-inputs","address":2,"manualAddress":"100003(0002)","type":"bit","name":{"ko":"HI 출력 상태","en":"OUT status HI"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.22 표 2.1.2","source":0},{"table":"holding-registers","address":0,"manualAddress":"400001(0000)","type":"s16","name":{"ko":"HI 프리셋 (H.SET)","en":"High preset (H.SET)"},"access":"rw","fc":[3,6,16],"description":{"ko":"출력 HIGH 설정값. 소수점 위치는 표시 설정(300002)에 따름.","en":"OUT HIGH set value. Decimal per display setting (300002)."},"ref":"인쇄 p.22 표 2.1.3.1","source":0},{"table":"holding-registers","address":1,"manualAddress":"400002(0001)","type":"s16","name":{"ko":"LO 프리셋 (L.SET)","en":"Low preset (L.SET)"},"access":"rw","fc":[3,6,16],"description":{"ko":"출력 LOW 설정값. 소수점 위치는 표시 설정(300002)에 따름.","en":"OUT LOW set value. Decimal per display setting (300002)."},"ref":"인쇄 p.22 표 2.1.3.1","source":0},{"table":"holding-registers","address":2,"manualAddress":"400003(0002)","type":"s16","name":{"ko":"최고 피크 (H.PEK)","en":"High peak (H.PEK)"},"access":"rw","fc":[3,6,16],"description":{"ko":"입력 최대값, 공장 기본 0.","en":"Max of input, default 0."},"ref":"인쇄 p.22 표 2.1.3.1","source":0},{"table":"holding-registers","address":3,"manualAddress":"400004(0003)","type":"s16","name":{"ko":"최저 피크 (L.PEK)","en":"Low peak (L.PEK)"},"access":"rw","fc":[3,6,16],"description":{"ko":"입력 최소값, 공장 기본 0.","en":"Min of input, default 0."},"ref":"인쇄 p.22 표 2.1.3.1","source":0},{"table":"holding-registers","address":100,"manualAddress":"400101(0064)","type":"u16","name":{"ko":"입력 레인지 (IN-R)","en":"Input range (IN-R)"},"access":"rw","fc":[3,6,16],"description":{"ko":"코드표는 측정 입력 사양 참조라고만 적혀 있다.","en":"Code table not given (refers to input specifications)."},"ref":"인쇄 p.22 표 2.1.3.2","source":0},{"table":"holding-registers","address":101,"manualAddress":"400102(0065)","type":"u16","name":{"ko":"표시 모드 (DISP)","en":"Display mode (DISP)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"STND 표준","en":"STND"},{"value":1,"ko":"SCAL 스케일","en":"SCAL"},{"value":2,"ko":"FREQ 주파수","en":"FREQ"}],"ref":"인쇄 p.22 표 2.1.3.2","source":0},{"table":"holding-registers","address":102,"manualAddress":"400103(0066)","type":"u16","name":{"ko":"소수점 (DOT)","en":"Decimal point (DOT)"},"access":"rw","fc":[3,6,16],"description":{"ko":"0~3. 매뉴얼 값 이름이 7세그 기호(«)000»…«0»)로만 적혀 자리 뜻은 확정하지 않았다.","en":"0-3; manual shows values only as 7-segment glyphs, so positions are not stated here."},"ref":"인쇄 p.22 표 2.1.3.2","source":0},{"table":"holding-registers","address":103,"manualAddress":"400104(0067)","type":"s16","name":{"ko":"스케일 상한 (H-SC)","en":"High scale"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"원시 범위. 소수점 위치에 따라 바뀐다.","en":"Raw range; changes with decimal point."},"ref":"인쇄 p.22 표 2.1.3.2","source":0},{"table":"holding-registers","address":104,"manualAddress":"400105(0068)","type":"s16","name":{"ko":"스케일 하한 (L-SC)","en":"Low scale"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"원시 범위. 소수점 위치에 따라 바뀐다.","en":"Raw range; changes with decimal point."},"ref":"인쇄 p.22 표 2.1.3.2","source":0},{"table":"holding-registers","address":105,"manualAddress":"400106(0069)","type":"u16","name":{"ko":"측정 방식 (IN-T, AC 입력)","en":"Input type (IN-T, AC models)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"T.RMS 실효값","en":"T.RMS"},{"value":1,"ko":"A.RMS","en":"A.RMS"},{"value":2,"ko":"AVG 평균","en":"AVG"}],"ref":"인쇄 p.22 표 2.1.3.2","source":0},{"table":"holding-registers","address":205,"manualAddress":"400206(00CD)","type":"u16","name":{"ko":"전면 영점 키 (ZERO)","en":"Front zero key"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"NO","en":"NO"},{"value":1,"ko":"YES","en":"YES"}],"ref":"인쇄 p.22 표 2.1.3.3","source":0},{"table":"holding-registers","address":206,"manualAddress":"400207(00CE)","type":"u16","name":{"ko":"외부 입력 단자 기능","en":"Event input function"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"HOLD","en":"HOLD"},{"value":1,"ko":"ZERO","en":"ZERO"}],"ref":"인쇄 p.22 표 2.1.3.3","source":0},{"table":"holding-registers","address":209,"manualAddress":"400210(00D1)","type":"u16","name":{"ko":"통신 국번","en":"Comm address"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":99},"ref":"인쇄 p.23 표 2.1.3.3","source":0},{"table":"holding-registers","address":210,"manualAddress":"400211(00D2)","type":"u16","name":{"ko":"통신 속도","en":"Comm speed"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200 bps","en":"1200 bps"},{"value":1,"ko":"2400 bps","en":"2400 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"9600 bps","en":"9600 bps"},{"value":4,"ko":"19200 bps","en":"19200 bps"},{"value":5,"ko":"38400 bps","en":"38400 bps"}],"ref":"인쇄 p.23 표 2.1.3.3","source":0},{"table":"holding-registers","address":211,"manualAddress":"400212(00D3)","type":"u16","name":{"ko":"패리티","en":"Parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"인쇄 p.23 표 2.1.3.3","source":0},{"table":"holding-registers","address":212,"manualAddress":"400213(00D4)","type":"u16","name":{"ko":"정지 비트","en":"Stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"인쇄 p.23 표 2.1.3.3","source":0},{"table":"holding-registers","address":213,"manualAddress":"400214(00D5)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response waiting time"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"인쇄 p.23 표 2.1.3.3","source":0},{"table":"holding-registers","address":214,"manualAddress":"400215(00D6)","type":"u16","name":{"ko":"잠금 (LOC)","en":"Lock (LOC)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"LOC1","en":"LOC1"},{"value":2,"ko":"LOC2","en":"LOC2"},{"value":3,"ko":"LOC3","en":"LOC3"}],"ref":"인쇄 p.23 표 2.1.3.3","source":0}],"notes":[{"ko":"RS485 는 출력 코드 8(NPN 오픈 컬렉터+RS485)·9(PNP+RS485) 모델만(제품 매뉴얼 p.2 주문 정보). models 의 □ 는 전원 코드(1: 12-24 VDC, 4: 100-240 VAC).","en":"RS485 only on output code 8 (NPN + RS485) and 9 (PNP + RS485) (product manual p.2). □ = power code (1: 12-24 VDC, 4: 100-240 VAC)."},{"ko":"같은 통신 매뉴얼의 MT4Y 표(2.2 절)는 보유 레지스터 주소가 다르다(예: 통신 국번이 400213(00D4)) — 이 파일은 MT4W 전용.","en":"MT4Y (section 2.2) uses different holding addresses (e.g. comm address at 400213(00D4)); this file is MT4W only."},{"ko":"통신 매뉴얼 쪽 번호: 인쇄 쪽 = PDF 쪽 - 1 (예: 인쇄 p.21 = PDF p.22).","en":"Page numbers: printed page = PDF page - 1."}],"sources":[{"title":"User Manual for Communication 4-Digit Multi Panel Meters MT Series MCT-MTC1-V1.7-EN","publisher":"Autonics","edition":{"ko":"MCT-MTC1-V1.7-EN (2024-11-26)","en":"MCT-MTC1-V1.7-EN (2024-11-26)"},"url":"https://www.autonics.com/glb/common/download/510417","pages":{"ko":"인쇄 pp.21-23 (PDF pp.22-24) 매핑 표, 인쇄 p.31 (PDF p.32) 공장 기본값","en":"printed pp.21-23 (PDF pp.22-24) mapping table, printed p.31 (PDF p.32) factory defaults"},"checked":"2026-10-19"},{"title":"4-Digit Multi Panel Meters MT4W Series PRODUCT MANUAL TCD220015AI","publisher":"Autonics","edition":{"ko":"MT4W_EN_TCD220015AI_20260629","en":"MT4W_EN_TCD220015AI_20260629"},"url":"https://www.autonics.com/glb/common/download/525959","pages":{"ko":"p.2 주문 정보, p.3 Communication Interface","en":"p.2 ordering information, p.3 Communication Interface"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/tk4","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"TK Series","models":["TK4S","TK4M","TK4W","TK4H","TK4L","TK4N"],"kind":"temperature-controller","title":{"ko":"오토닉스 TK 시리즈 PID 온도 조절기 (RS485 모델)","en":"Autonics TK Series PID temperature controller (RS485 models)"},"summary":{"ko":"가열·냉각 동시 출력 PID 온도 조절기. RS485 옵션 모델만 Modbus RTU 슬레이브. 코일(RUN/STOP·오토튜닝), 입력 레지스터(PV·SV·MV·표시 상태), 보유 레지스터(설정값·PID·입력·경보·통신)를 담았다.","en":"Heating & cooling PID temperature controller. Only RS485-option models are Modbus RTU slaves. Covers coils (RUN/STOP, auto-tuning), input registers (PV, SV, MV, indicator status) and holding registers (SV, PID, input, alarm, comm)."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,99],"notes":[{"ko":"통신 기본값: 통신 매뉴얼 p.37 (ADRS 기본 01, BPS 기본 2=9600, PRTY 기본 NONE, STP 기본 2비트, 응답 대기 20 ms). 데이터 8비트 고정·지원 속도·최대 31대는 사용자 매뉴얼(MCT-TKU1-V3.6-EN) p.27 «Communication Interface».","en":"Defaults from comm manual p.37 (ADRS 01, BPS 2=9600, parity NONE, stop 2, response wait 20 ms). 8 data bits fixed, speed list and max 31 units from user manual MCT-TKU1-V3.6-EN p.27."},{"ko":"매뉴얼은 «400001(0000)» 꼴로 적는다 — 앞은 1 기준 참조 번호(0x=코일, 1x=입력 접점, 3x=입력 레지스터, 4x=보유 레지스터), 괄호 안은 16진 통신 주소. 첫 항목이 (0000) 에서 시작하므로 괄호 값을 0 기준 프레임 주소로 썼다(통신 매뉴얼 p.23~41). 다만 매뉴얼의 프레임 예시(p.12~20)는 바이트 자리만 보이고 실제 숫자 예가 없다.","en":"Manual writes «400001(0000)»: 1-based reference number plus hex comm address in parentheses; first entries are (0000), so the parenthesized value is used as the 0-based wire address (pp.23-41). The frame examples (pp.12-20) show only field layout, no numeric example."}]},"registers":[{"table":"coils","address":0,"manualAddress":"000001 (0000)","type":"bit","name":{"ko":"제어 출력 RUN/STOP","en":"Control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.23 표 2.1","source":0},{"table":"coils","address":1,"manualAddress":"000002 (0001)","type":"bit","name":{"ko":"오토튜닝 실행","en":"Auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 표 2.1","source":0},{"table":"input-registers","address":1000,"manualAddress":"301001(03E8)","type":"s16","name":{"ko":"현재값 PV","en":"Present value (PV)"},"access":"r","fc":[4],"range":{"min":-1999,"max":9999},"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 입력 설정에 따름 — 소수점 레지스터 301002(03E9) 참조. 단위는 301003(03EA).","en":"Decimal point depends on input setting — see 301002(03E9). Unit in 301003(03EA)."},"ref":"p.25 표 2.3","source":0},{"table":"input-registers","address":1001,"manualAddress":"301002(03E9)","type":"u16","name":{"ko":"소수점 위치","en":"Decimal point position"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"},{"value":2,"ko":"0.00","en":"0.00"},{"value":3,"ko":"0.000","en":"0.000"}],"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1002,"manualAddress":"301003(03EA)","type":"u16","name":{"ko":"표시 단위","en":"Indicator unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"},{"value":2,"ko":"%","en":"%"},{"value":3,"ko":"없음(OFF)","en":"OFF"}],"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1003,"manualAddress":"301004(03EB)","type":"s16","name":{"ko":"설정값 SV(읽기)","en":"Set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"L-SV~H-SV 안. 소수점 위치는 입력 설정에 따름(301002).","en":"Within L-SV..H-SV. Decimal point per input setting (301002)."},"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1004,"manualAddress":"301005(03EC)","type":"u16","name":{"ko":"가열 측 조작량 H-MV","en":"Heating MV (H-MV)"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1005,"manualAddress":"301006(03ED)","type":"u16","name":{"ko":"냉각 측 조작량 C-MV","en":"Cooling MV (C-MV)"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1006,"manualAddress":"301007(03EE)","type":"u16","name":{"ko":"표시·입력 상태 비트","en":"Indicator/input status bits"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"℃ 표시등","en":"°C indicator"},{"bit":1,"ko":"℉ 표시등","en":"°F indicator"},{"bit":2,"ko":"% 표시등","en":"% indicator"},{"bit":3,"ko":"제어 출력 1(OUT1)","en":"OUT1 indicator"},{"bit":4,"ko":"제어 출력 2(OUT2)","en":"OUT2 indicator"},{"bit":5,"ko":"오토튜닝 중(AT)","en":"AT indicator"},{"bit":6,"ko":"멀티 SV1","en":"Multi SV1 indicator"},{"bit":7,"ko":"멀티 SV2","en":"Multi SV2 indicator"},{"bit":8,"ko":"멀티 SV3","en":"Multi SV3 indicator"},{"bit":9,"ko":"경보 출력 1(AL1)","en":"AL1 indicator"},{"bit":10,"ko":"경보 출력 2(AL2)","en":"AL2 indicator"},{"bit":11,"ko":"수동 제어(MAN)","en":"Manual control indicator"},{"bit":12,"ko":"디지털 입력 DI-1","en":"DI-1 input"},{"bit":13,"ko":"디지털 입력 DI-2","en":"DI-2 input"}],"ref":"p.27 «301007 (03EE) Bit data»","source":0},{"table":"input-registers","address":1007,"manualAddress":"301008(03EF)","type":"u16","name":{"ko":"히터 전류 모니터","en":"Heater current monitoring"},"access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~50.0. 이 주소엔 원시값 배율이 적혀 있지 않다(보유 레지스터 400053 CT-A 는 0~500 → 0.0~50.0 A).","en":"Manual range 0.0-50.0; raw scaling not stated for this address (holding 400053 CT-A gives 0-500 → 0.0-50.0 A)."},"ref":"p.26 표 2.3","source":0},{"table":"holding-registers","address":0,"manualAddress":"400001(0000)","type":"s16","name":{"ko":"설정값 SV","en":"Set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"L-SV~H-SV 안. 소수점 위치는 입력 설정에 따름(입력 레지스터 301002).","en":"Within L-SV..H-SV. Decimal point per input setting (input reg 301002)."},"ref":"p.28 표 2.4.1","source":0},{"table":"holding-registers","address":1,"manualAddress":"400002(0001)","type":"u16","name":{"ko":"가열 조작량 H-MV","en":"Heating MV (H-MV)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.28 표 2.4.1","source":0},{"table":"holding-registers","address":2,"manualAddress":"400003(0002)","type":"u16","name":{"ko":"냉각 조작량 C-MV","en":"Cooling MV (C-MV)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.28 표 2.4.1","source":0},{"table":"holding-registers","address":3,"manualAddress":"400004(0003)","type":"u16","name":{"ko":"자동/수동 제어","en":"Auto/manual control"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"자동(AUTO)","en":"AUTO"},{"value":1,"ko":"수동(MAN)","en":"MAN"}],"ref":"p.28 표 2.4.1","source":0},{"table":"holding-registers","address":50,"manualAddress":"400051(0032)","type":"u16","name":{"ko":"제어 출력 RUN/STOP (R-S)","en":"Control output Run/Stop (R-S)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":51,"manualAddress":"400052(0033)","type":"u16","name":{"ko":"멀티 SV 번호 (SV-N)","en":"Multi SV number (SV-N)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"SV-0","en":"SV-0"},{"value":1,"ko":"SV-1","en":"SV-1"},{"value":2,"ko":"SV-2","en":"SV-2"},{"value":3,"ko":"SV-3","en":"SV-3"}],"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":53,"manualAddress":"400054(0035)","type":"s16","name":{"ko":"경보 1 하한 설정 (AL1.L)","en":"Alarm 1 low-limit (AL1.L)"},"access":"rw","fc":[3,6,16],"description":{"ko":"편차 경보: -F.S.~F.S., 절대값 경보: 표시 범위 안. 소수점은 입력 설정에 따름.","en":"Deviation: -F.S..F.S.; absolute: within display range. Decimal point per input setting."},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":54,"manualAddress":"400055(0036)","type":"s16","name":{"ko":"경보 1 상한 설정 (AL1.H)","en":"Alarm 1 high-limit (AL1.H)"},"access":"rw","fc":[3,6,16],"description":{"ko":"편차 경보: -F.S.~F.S., 절대값 경보: 표시 범위 안. 소수점은 입력 설정에 따름.","en":"Deviation: -F.S..F.S.; absolute: within display range. Decimal point per input setting."},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":55,"manualAddress":"400056(0037)","type":"s16","name":{"ko":"경보 2 하한 설정 (AL2.L)","en":"Alarm 2 low-limit (AL2.L)"},"access":"rw","fc":[3,6,16],"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":56,"manualAddress":"400057(0038)","type":"s16","name":{"ko":"경보 2 상한 설정 (AL2.H)","en":"Alarm 2 high-limit (AL2.H)"},"access":"rw","fc":[3,6,16],"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":100,"manualAddress":"400101(0064)","type":"u16","name":{"ko":"오토튜닝 실행/정지 (AT)","en":"Auto-tuning run/stop (AT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":101,"manualAddress":"400102(0065)","type":"u16","name":{"ko":"가열 비례대 (H-P)","en":"Heating proportional band (H-P)"},"scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":999.9},"description":{"ko":"원시 1~9999 = 0.1~999.9, 단위 ℃/℉/%(입력에 따름).","en":"Raw 1-9999 = 0.1-999.9, unit °C/°F/% depending on input."},"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":103,"manualAddress":"400104(0067)","type":"u16","name":{"ko":"가열 적분 시간 (H-I)","en":"Heating integral time (H-I)"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":105,"manualAddress":"400106(0069)","type":"u16","name":{"ko":"가열 미분 시간 (H-D)","en":"Heating derivative time (H-D)"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":150,"manualAddress":"400151(0096)","type":"u16","name":{"ko":"입력 종류 (IN-T)","en":"Input type (IN-T)"},"access":"rw","fc":[3,6,16],"description":{"ko":"공장 기본 0 = KCA.H(K 열전대). 나머지 코드 번호는 통신 매뉴얼에 표가 없다(«Input Type and Using Range» 참조라고만 적힘).","en":"Default 0 = KCA.H (K thermocouple). The comm manual gives no code table for other types."},"ref":"p.33 표 2.4.4","source":0},{"table":"holding-registers","address":151,"manualAddress":"400152(0097)","type":"u16","name":{"ko":"온도 단위 (UNIT)","en":"Temperature unit (UNIT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.33 표 2.4.4","source":0},{"table":"holding-registers","address":154,"manualAddress":"400155(009A)","type":"u16","name":{"ko":"스케일 소수점 (DOT, 아날로그 입력)","en":"Scaling decimal point (DOT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"},{"value":2,"ko":"0.00","en":"0.00"},{"value":3,"ko":"0.000","en":"0.000"}],"ref":"p.33 표 2.4.4","source":0},{"table":"holding-registers","address":158,"manualAddress":"400159(009E)","type":"s16","name":{"ko":"입력 보정 (IN-B)","en":"Input correction (IN-B)"},"access":"rw","fc":[3,6,16],"description":{"ko":"-999~999 (Temp.H·아날로그) 또는 -1999~9999 = -199.9~999.9 (Temp.L). 소수점은 입력 설정에 따름.","en":"-999..999 (Temp.H, analog) or -1999..9999 = -199.9..999.9 (Temp.L). Decimal per input setting."},"ref":"p.33 표 2.4.4","source":0},{"table":"holding-registers","address":160,"manualAddress":"400161(00A0)","type":"s16","name":{"ko":"SV 하한 (L-SV)","en":"SV low limit (L-SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"입력 하한~H-SV-1digit. 소수점은 입력 설정에 따름.","en":"Input low..H-SV minus 1 digit. Decimal per input setting."},"ref":"p.33 표 2.4.4","source":0},{"table":"holding-registers","address":161,"manualAddress":"400162(00A1)","type":"s16","name":{"ko":"SV 상한 (H-SV)","en":"SV high limit (H-SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"L-SV+1digit~입력 상한. 소수점은 입력 설정에 따름.","en":"L-SV plus 1 digit..input high. Decimal per input setting."},"ref":"p.33 표 2.4.4","source":0},{"table":"holding-registers","address":163,"manualAddress":"400164(00A3)","type":"u16","name":{"ko":"제어 방식 (C-MD)","en":"Control type (C-MD)"},"access":"rw","fc":[3,6,16],"description":{"ko":"표준 제어형: 0 PID, 1 ON/OFF. 가열·냉각형: 0 P.P, 1 P.ON, 2 ON.P, 3 ON.ON.","en":"Standard: 0 PID, 1 ON/OFF. Heating&cooling: 0 P.P, 1 P.ON, 2 ON.P, 3 ON.ON."},"ref":"p.34 표 2.4.4","source":0},{"table":"holding-registers","address":200,"manualAddress":"400201(00C8)","type":"u16","name":{"ko":"경보 1 동작 모드 (AL-1)","en":"Alarm 1 operation mode (AL-1)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"DVCC","en":"DVCC"},{"value":2,"ko":"]]DV","en":"]]DV"},{"value":3,"ko":"]DVC","en":"]DVC"},{"value":4,"ko":"CDV]","en":"CDV]"},{"value":5,"ko":"PVCC","en":"PVCC"},{"value":6,"ko":"]]PV","en":"]]PV"},{"value":7,"ko":"LBA","en":"LBA"},{"value":8,"ko":"SBA","en":"SBA"},{"value":9,"ko":"HBA","en":"HBA"}],"description":{"ko":"값 이름은 매뉴얼 표시 기호 그대로. 각 모드의 뜻은 사용자 매뉴얼 경보 절 참조. 공장 기본 1(DVCC).","en":"Names as printed (display symbols); see user manual alarm section for meanings. Default 1 (DVCC)."},"ref":"p.36 표 2.4.5","source":0},{"table":"holding-registers","address":206,"manualAddress":"400207(00CE)","type":"u16","name":{"ko":"경보 2 동작 모드 (AL-2)","en":"Alarm 2 operation mode (AL-2)"},"access":"rw","fc":[3,6,16],"description":{"ko":"값 코드는 AL-1 과 같다(0 OFF … 9 HBA). 공장 기본 2(]]DV).","en":"Same codes as AL-1 (0 OFF … 9 HBA). Default 2 (]]DV)."},"ref":"p.36 표 2.4.5","source":0},{"table":"holding-registers","address":218,"manualAddress":"400219(00DA)","type":"u16","name":{"ko":"통신 국번 (ADRS)","en":"Comm address (ADRS)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":99},"ref":"p.37 표 2.4.5","source":0},{"table":"holding-registers","address":219,"manualAddress":"400220(00DB)","type":"u16","name":{"ko":"통신 속도 (BPS)","en":"Comm speed (BPS)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"}],"ref":"p.37 표 2.4.5","source":0},{"table":"holding-registers","address":220,"manualAddress":"400221(00DC)","type":"u16","name":{"ko":"패리티 (PRTY)","en":"Parity (PRTY)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"p.37 표 2.4.5","source":0},{"table":"holding-registers","address":221,"manualAddress":"400222(00DD)","type":"u16","name":{"ko":"정지 비트 (STP)","en":"Stop bit (STP)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"p.37 표 2.4.5","source":0},{"table":"holding-registers","address":222,"manualAddress":"400223(00DE)","type":"u16","name":{"ko":"응답 대기 시간 (RSW.T)","en":"Response waiting time (RSW.T)"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.37 표 2.4.5","source":0},{"table":"holding-registers","address":223,"manualAddress":"400224(00DF)","type":"u16","name":{"ko":"통신 쓰기 허용 (COMW)","en":"Comm write enable (COMW)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"허용(EN.A)","en":"Enabled (EN.A)"},{"value":1,"ko":"금지(DIS.A)","en":"Disabled (DIS.A)"}],"ref":"p.37 표 2.4.5","source":0}],"notes":[{"ko":"RS485 는 옵션 모델만: S·M·W·H·L 크기는 옵션 T(경보1+RS485)·B(경보1+경보2+RS485), N 크기는 옵션 T(사용자 매뉴얼 p.18~19 주문 정보). TK4SP 주문표엔 RS485 옵션이 없다.","en":"RS485 only on option models: sizes S/M/W/H/L option T or B; size N option T (user manual pp.18-19). TK4SP ordering table has no RS485 option."},{"ko":"입력 접점(1x) 100001(0000)~100014(000D) 은 입력 레지스터 301007 의 비트 0~13 과 같은 항목·같은 순서다(p.24) — 여기선 레지스터 쪽만 넣었다.","en":"Discrete inputs 100001(0000)-100014(000D) list the same items in the same order as bits 0-13 of input reg 301007 (p.24); only the register is included."},{"ko":"오류 응답 코드 01·02·03·04·06 (p.21). 통신 쓰기 금지(COMW=DIS.A)·파라미터 잠금 상태면 쓰기가 거부된다.","en":"Exception codes 01/02/03/04/06 (p.21). Writes are refused when locked or COMW=DIS.A."},{"ko":"PLC·HMI 연결 시 여러 레지스터 쓰기(16)보다 단일 쓰기(06)를 권장(p.20).","en":"Manual recommends FC06 over FC16 for PLC/HMI (p.20)."}],"sources":[{"title":"TK Series Simultaneous Heating&Cooling Output PID Temperature Controllers Communication Manual MCT-TKC1-V2.2-EN","publisher":"Autonics","edition":{"ko":"MCT-TKC1-V2.2-EN (PDF 작성 2026-02-11)","en":"MCT-TKC1-V2.2-EN (PDF created 2026-02-11)"},"url":"https://www.autonics.com/glb/common/download/522980","pages":{"ko":"pp.21-41 (인쇄 쪽 = PDF 쪽)","en":"pp.21-41 (printed page = PDF page)"},"checked":"2026-10-19"},{"title":"TK Series Simultaneous Heating&Cooling Output PID Temperature Controllers User Manual MCT-TKU1-V3.6-EN","publisher":"Autonics","edition":{"ko":"MCT-TKU1-V3.6-EN (PDF 작성 2026-06-15)","en":"MCT-TKU1-V3.6-EN (PDF created 2026-06-15)"},"url":"https://www.autonics.com/glb/common/download/525784","pages":{"ko":"pp.18-19 주문 정보, p.27 통신 인터페이스","en":"pp.18-19 ordering information, p.27 Communication Interface"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/tm2","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"TM2","models":["TM2-22RB","TM2-22CB","TM2-42RB","TM2-42CB","TM2-22RE","TM2-22CE","TM2-42RE","TM2-42CE"],"kind":"temperature-controller","title":{"ko":"오토닉스 TM2 모듈형 2채널 PID 온도 조절기","en":"Autonics TM2 modular 2-channel PID temperature controller"},"summary":{"ko":"DIN 레일 모듈형 2채널 온도 조절기(경보 2·4점, CT·디지털 입력). 기본 모듈(…B)에 RS485 Modbus RTU/ASCII. 코일·입력 접점(LED·DI), 입력 레지스터(채널별 PV·SV·MV·CT 전류), CH1 보유 레지스터와 경보 1 설정을 담았다.","en":"DIN-rail modular 2-channel controller with 2/4 alarms, CT and digital inputs; RS485 Modbus RTU/ASCII on the basic module (…B). Covers coils, discrete inputs (LEDs, DI), input registers (per-channel PV/SV/MV, CT current), CH1 holding registers and alarm 1 settings."},"protocols":["rtu","ascii"],"comm":{"addressing":"zero","baud":9600,"bauds":[2400,4800,9600,19200,38400,57600,115200],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,31],"notes":[{"ko":"통신 기본값: 사용자 매뉴얼 «1.5.2 Communication Interface»(p.28) — 9600bps(기본), 데이터 8비트 고정, 패리티 None(기본), 정지 2비트(기본), 응답 대기 20 ms, 최대 31대(국번 01~31). 통신 매뉴얼 3.4.7 공장 기본값(속도 2=9600, 패리티 0, 정지 1=2비트)과 같다.","en":"Defaults from user manual 1.5.2 (p.28): 9600 bps, 8 data bits fixed, parity none, 2 stop bits, response wait 20 ms, up to 31 units (01-31); matches comm manual 3.4.7 factory defaults."},{"ko":"매뉴얼은 «400001 (0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(통신 매뉴얼 pp.37-57). 1.1 절 프레임 예시는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «400001 (0000)»: 1-based reference plus hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (pp.37-57). Frame examples in 1.1 show layout only."},{"ko":"통신 설정을 바꾸면 기기를 다시 켜야 정상 동작한다(사용자 매뉴얼 p.28).","en":"Reboot after changing communication settings (user manual p.28)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"000001 (0000)","type":"bit","name":{"ko":"CH1 제어 출력 RUN/STOP","en":"CH1 control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.37 3.1"},{"table":"coils","address":1,"manualAddress":"000002 (0001)","type":"bit","name":{"ko":"CH1 오토튜닝 실행","en":"CH1 auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.37 3.1"},{"table":"coils","address":2,"manualAddress":"000003 (0002)","type":"bit","name":{"ko":"CH2 제어 출력 RUN/STOP","en":"CH2 control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.37 3.1"},{"table":"coils","address":3,"manualAddress":"000004 (0003)","type":"bit","name":{"ko":"CH2 오토튜닝 실행","en":"CH2 auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.37 3.1"},{"table":"discrete-inputs","address":0,"manualAddress":"100001 (0000)","type":"bit","name":{"ko":"CH1 출력 LED(OUT)","en":"CH1 output LED (OUT)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":1,"manualAddress":"100002 (0001)","type":"bit","name":{"ko":"CH2 출력 LED(OUT)","en":"CH2 output LED (OUT)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":4,"manualAddress":"100005 (0004)","type":"bit","name":{"ko":"AL1 LED","en":"AL1 LED"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":5,"manualAddress":"100006 (0005)","type":"bit","name":{"ko":"AL2 LED","en":"AL2 LED"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":6,"manualAddress":"100007 (0006)","type":"bit","name":{"ko":"AL3 LED","en":"AL3 LED"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":7,"manualAddress":"100008 (0007)","type":"bit","name":{"ko":"AL4 LED","en":"AL4 LED"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":8,"manualAddress":"100009 (0008)","type":"bit","name":{"ko":"디지털 입력 1(DI-1)","en":"Digital input 1 (DI-1)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":9,"manualAddress":"100010 (0009)","type":"bit","name":{"ko":"디지털 입력 2(DI-2)","en":"Digital input 2 (DI-2)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"input-registers","address":103,"manualAddress":"300104 (0067)","type":"u16","name":{"ko":"소프트웨어 버전","en":"Software version"},"access":"r","fc":[4],"ref":"p.39 3.3"},{"table":"input-registers","address":125,"manualAddress":"300126 (007D)","type":"u16","name":{"ko":"채널 수","en":"Channel quantity"},"access":"r","fc":[4],"ref":"p.39 3.3"},{"table":"input-registers","address":1000,"manualAddress":"301001 (03E8)","type":"s16","name":{"ko":"CH1 현재값 PV","en":"CH1 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1001,"manualAddress":"301002 (03E9)","type":"u16","name":{"ko":"CH1 소수점 위치","en":"CH1 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1002,"manualAddress":"301003 (03EA)","type":"u16","name":{"ko":"CH1 온도 단위","en":"CH1 temperature unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1003,"manualAddress":"301004 (03EB)","type":"s16","name":{"ko":"CH1 설정값 SV(읽기)","en":"CH1 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1004,"manualAddress":"301005 (03EC)","type":"u16","name":{"ko":"CH1 가열 조작량","en":"CH1 heating MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1005,"manualAddress":"301006 (03ED)","type":"u16","name":{"ko":"CH1 냉각 조작량","en":"CH1 cooling MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1006,"manualAddress":"301007 (03EE)","type":"s16","name":{"ko":"CH2 현재값 PV","en":"CH2 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1007,"manualAddress":"301008 (03EF)","type":"u16","name":{"ko":"CH2 소수점 위치","en":"CH2 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1008,"manualAddress":"301009 (03F0)","type":"u16","name":{"ko":"CH2 온도 단위","en":"CH2 temperature unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1009,"manualAddress":"301010 (03F1)","type":"s16","name":{"ko":"CH2 설정값 SV(읽기)","en":"CH2 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1010,"manualAddress":"301011 (03F2)","type":"u16","name":{"ko":"CH2 가열 조작량","en":"CH2 heating MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1011,"manualAddress":"301012 (03F3)","type":"u16","name":{"ko":"CH2 냉각 조작량","en":"CH2 cooling MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1024,"manualAddress":"301025 (0400)","type":"u16","name":{"ko":"표시 상태 비트","en":"Indicator bits"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"CH1 출력 LED","en":"CH1 output LED"},{"bit":1,"ko":"CH2 출력 LED","en":"CH2 output LED"},{"bit":4,"ko":"AL1 LED","en":"AL1 LED"},{"bit":5,"ko":"AL2 LED","en":"AL2 LED"},{"bit":6,"ko":"AL3 LED","en":"AL3 LED"},{"bit":7,"ko":"AL4 LED","en":"AL4 LED"},{"bit":8,"ko":"디지털 입력 1 ON","en":"Digital input 1 ON"},{"bit":9,"ko":"디지털 입력 2 ON","en":"Digital input 2 ON"}],"ref":"p.41 3.3"},{"table":"input-registers","address":1025,"manualAddress":"301026 (0401)","type":"u16","name":{"ko":"통신 국번","en":"Unit address"},"access":"r","fc":[4],"range":{"min":1,"max":31},"ref":"p.40 3.3"},{"table":"input-registers","address":1026,"manualAddress":"301027 (0402)","type":"u16","name":{"ko":"CT1 히터 전류","en":"CT1 heater current"},"unit":"A","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~50.0 A. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-50.0 A; raw scaling not stated."},"ref":"p.40 3.3"},{"table":"input-registers","address":1027,"manualAddress":"301028 (0403)","type":"u16","name":{"ko":"CT2 히터 전류","en":"CT2 heater current"},"unit":"A","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~50.0 A. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-50.0 A; raw scaling not stated."},"ref":"p.40 3.3"},{"table":"holding-registers","address":0,"manualAddress":"400001 (0000)","type":"s16","name":{"ko":"CH1 설정값 SV","en":"CH1 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"SV 하한~SV 상한. 소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"SV low limit to SV high limit. Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":1,"manualAddress":"400002 (0001)","type":"u16","name":{"ko":"CH1 가열 조작량","en":"CH1 heating MV"},"unit":"%","access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":2,"manualAddress":"400003 (0002)","type":"u16","name":{"ko":"CH1 냉각 조작량","en":"CH1 cooling MV"},"unit":"%","access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":3,"manualAddress":"400004 (0003)","type":"u16","name":{"ko":"CH1 자동/수동 제어","en":"CH1 auto/manual control"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"자동(AUTO)","en":"AUTO"},{"value":1,"ko":"수동(MANUAL)","en":"MANUAL"}],"ref":"p.42 3.4.1"},{"table":"holding-registers","address":1000,"manualAddress":"401001 (03E8)","type":"s16","name":{"ko":"CH2 설정값 SV","en":"CH2 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":100,"manualAddress":"400101 (0064)","type":"u16","name":{"ko":"CH1 제어 출력 RUN/STOP","en":"CH1 control output RUN/STOP"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.43 3.4.2"},{"table":"holding-registers","address":101,"manualAddress":"400102 (0065)","type":"u16","name":{"ko":"CH1 멀티 SV 번호","en":"CH1 multi SV number"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"SV-0","en":"SV-0"},{"value":1,"ko":"SV-1","en":"SV-1"},{"value":2,"ko":"SV-2","en":"SV-2"},{"value":3,"ko":"SV-3","en":"SV-3"}],"ref":"p.43 3.4.2"},{"table":"holding-registers","address":200,"manualAddress":"400201 (00C8)","type":"u16","name":{"ko":"CH1 오토튜닝 실행","en":"CH1 auto-tuning execute"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.43 3.4.2"},{"table":"holding-registers","address":201,"manualAddress":"400202 (00C9)","type":"u16","name":{"ko":"CH1 가열 비례대","en":"CH1 heating proportional band"},"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 범위 0.1~999.9 ℃. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.1-999.9 °C; raw scaling not stated."},"ref":"p.43 3.4.2"},{"table":"holding-registers","address":203,"manualAddress":"400204 (00CB)","type":"u16","name":{"ko":"CH1 가열 적분 시간","en":"CH1 heating integral time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.44 3.4.2"},{"table":"holding-registers","address":205,"manualAddress":"400206 (00CD)","type":"u16","name":{"ko":"CH1 가열 미분 시간","en":"CH1 heating derivative time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.44 3.4.2"},{"table":"holding-registers","address":300,"manualAddress":"400301 (012C)","type":"u16","name":{"ko":"CH1 입력 종류","en":"CH1 input type"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":26},"description":{"ko":"0 K(CA).H ~ 26 NI12. 코드표는 사용자 매뉴얼 «Input type» 참조.","en":"0 K(CA).H to 26 NI12; code table in the user manual 'Input type'."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":301,"manualAddress":"400302 (012D)","type":"u16","name":{"ko":"CH1 온도 단위","en":"CH1 temperature unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.46 3.4.3"},{"table":"holding-registers","address":302,"manualAddress":"400303 (012E)","type":"s16","name":{"ko":"CH1 입력 보정","en":"CH1 input bias"},"access":"rw","fc":[3,6,16],"description":{"ko":"-999~999(H) / -999.9~999.9(L) digit","en":"-999..999 (H) / -999.9..999.9 (L) digit"},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":304,"manualAddress":"400305 (0130)","type":"s16","name":{"ko":"CH1 SV 하한","en":"CH1 SV low limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":305,"manualAddress":"400306 (0131)","type":"s16","name":{"ko":"CH1 SV 상한","en":"CH1 SV high limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":306,"manualAddress":"400307 (0132)","type":"u16","name":{"ko":"CH1 제어 출력 동작","en":"CH1 control output mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"가열","en":"Heating"},{"value":1,"ko":"냉각","en":"Cooling"},{"value":2,"ko":"가열·냉각","en":"Heating & cooling"}],"ref":"p.46 3.4.3"},{"table":"holding-registers","address":307,"manualAddress":"400308 (0133)","type":"u16","name":{"ko":"CH1 제어 방식","en":"CH1 control method"},"access":"rw","fc":[3,6,16],"description":{"ko":"가열 또는 냉각: 0 PID, 1 ON/OFF. 가열·냉각: 0 PID-PID, 1 PID-ONOFF, 2 ONOFF-PID, 3 ONOFF-ONOFF.","en":"Heating or cooling: 0 PID, 1 ON/OFF. Heating & cooling: 0 PID-PID, 1 PID-ONOFF, 2 ONOFF-PID, 3 ONOFF-ONOFF."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":600,"manualAddress":"400601 (0258)","type":"u16","name":{"ko":"통신 속도","en":"Baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"},{"value":5,"ko":"57600 bps","en":"57600 bps"},{"value":6,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":601,"manualAddress":"400602 (0259)","type":"u16","name":{"ko":"패리티","en":"Parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":602,"manualAddress":"400603 (025A)","type":"u16","name":{"ko":"정지 비트","en":"Stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":603,"manualAddress":"400604 (025B)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response waiting time"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.56 3.4.7"},{"table":"holding-registers","address":604,"manualAddress":"400605 (025C)","type":"u16","name":{"ko":"통신 쓰기 허용","en":"Communication write"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"허용","en":"ENABLE"},{"value":1,"ko":"금지","en":"DISABLE"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":606,"manualAddress":"400607 (025E)","type":"u16","name":{"ko":"통신 프로토콜","en":"Communication protocol"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RTU","en":"RTU"},{"value":1,"ko":"ASCII","en":"ASCII"}],"ref":"p.57 3.4.7"},{"table":"holding-registers","address":500,"manualAddress":"400501 (01F4)","type":"u16","name":{"ko":"경보 1 대상 채널","en":"Alarm 1 target CH"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"CH1","en":"CH1"},{"value":1,"ko":"CH2","en":"CH2"},{"value":2,"ko":"CH1 또는 CH2","en":"CH1 or CH2"},{"value":3,"ko":"CH1 그리고 CH2","en":"CH1 and CH2"}],"ref":"p.50 3.4.5"},{"table":"holding-registers","address":501,"manualAddress":"400502 (01F5)","type":"u16","name":{"ko":"경보 1 동작 모드","en":"Alarm 1 operation mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"AL-1","en":"AL-1"},{"value":2,"ko":"AL-2","en":"AL-2"},{"value":3,"ko":"AL-3","en":"AL-3"},{"value":4,"ko":"AL-4","en":"AL-4"},{"value":5,"ko":"AL-5","en":"AL-5"},{"value":6,"ko":"AL-6","en":"AL-6"},{"value":7,"ko":"LBA","en":"LBA"},{"value":8,"ko":"SBA","en":"SBA"},{"value":9,"ko":"HBA","en":"HBA"}],"ref":"p.50 3.4.5"},{"table":"holding-registers","address":503,"manualAddress":"400504 (01F7)","type":"s16","name":{"ko":"경보 1 CH1 하한","en":"Alarm 1 CH1 low limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"편차 경보 -F.S~F.S, 절대값 경보는 센서 입력 범위 안","en":"Deviation: -F.S..F.S; absolute: within sensor range"},"ref":"p.50 3.4.5"},{"table":"holding-registers","address":504,"manualAddress":"400505 (01F8)","type":"s16","name":{"ko":"경보 1 CH1 상한","en":"Alarm 1 CH1 high limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"편차 경보 -F.S~F.S, 절대값 경보는 센서 입력 범위 안","en":"Deviation: -F.S..F.S; absolute: within sensor range"},"ref":"p.50 3.4.5"}],"notes":[{"ko":"TM2 와 TM4 는 보유 레지스터 주소가 다르다(통신 매뉴얼 p.37) — 이 파일은 TM2 전용.","en":"TM2 and TM4 use different holding addresses (p.37); this file is TM2 only."},{"ko":"보유 레지스터는 CH1 만 적었다. CH2 는 같은 순서로 +1000(03E8h): 예) CH2 SV 401001(03E8), CH2 RUN/STOP 401101(044C), CH2 오토튜닝 401201(04B0) (pp.42-47).","en":"Holding registers list CH1; CH2 follows at +1000 (03E8h), e.g. CH2 SV 401001(03E8), CH2 RUN/STOP 401101(044C), CH2 AT 401201(04B0) (pp.42-47)."},{"ko":"경보 2~4 는 경보 1 다음에 18칸씩: 경보 2 대상 채널 400519(0206), 경보 3 400537(0218), 경보 4 400555(022A) (pp.50-55).","en":"Alarms 2-4 follow alarm 1 every 18 registers: alarm 2 target 400519(0206), alarm 3 400537(0218), alarm 4 400555(022A) (pp.50-55)."},{"ko":"경보 출력 3·4 는 TM2-42□□ 모델만(사용자 매뉴얼 p.19).","en":"Alarm outputs 3/4 only on TM2-42□□ (user manual p.19)."}],"sources":[{"title":"TM Series Communication Manual MWA-TMC1-V2.2-EN","publisher":"Autonics","edition":{"ko":"MWA-TMC1-V2.2-EN (PDF 작성 2026-08-26)","en":"MWA-TMC1-V2.2-EN (PDF created 2026-08-26)"},"url":"https://www.autonics.com/glb/common/download/528500","pages":{"ko":"pp.37-57 매핑 표 (인쇄 쪽 = PDF 쪽)","en":"pp.37-57 mapping table (printed page = PDF page)"},"checked":"2026-10-22"},{"title":"TM Series User Manual MCT-TMU1-V4.0-EN","publisher":"Autonics","edition":{"ko":"MCT-TMU1-V4.0-EN (PDF 작성 2026-08-19)","en":"MCT-TMU1-V4.0-EN (PDF created 2026-08-19)"},"url":"https://www.autonics.com/glb/common/download/528473","pages":{"ko":"pp.18-19 주문 정보, p.28 통신 인터페이스","en":"pp.18-19 ordering information, p.28 Communication Interface"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/tm4","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"TM4","models":["TM4-N2RB","TM4-N2SB","TM4-N2RE","TM4-N2SE"],"kind":"temperature-controller","title":{"ko":"오토닉스 TM4 모듈형 4채널 PID 온도 조절기","en":"Autonics TM4 modular 4-channel PID temperature controller"},"summary":{"ko":"DIN 레일 모듈형 4채널 온도 조절기. 기본 모듈(…B)에 RS485 Modbus RTU/ASCII. 코일(채널별 RUN/STOP·오토튜닝), 입력 레지스터(채널별 PV·SV·MV), CH1 보유 레지스터(SV·PID·입력·통신 설정)를 담았다.","en":"DIN-rail modular 4-channel temperature controller; RS485 Modbus RTU/ASCII on the basic module (…B). Covers coils (per-channel RUN/STOP, auto-tuning), input registers (per-channel PV/SV/MV) and CH1 holding registers (SV, PID, input, comm)."},"protocols":["rtu","ascii"],"comm":{"addressing":"zero","baud":9600,"bauds":[2400,4800,9600,19200,38400,57600,115200],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,31],"notes":[{"ko":"통신 기본값: 사용자 매뉴얼 «1.5.2 Communication Interface»(p.28) — 9600bps(기본), 데이터 8비트 고정, 패리티 None(기본), 정지 2비트(기본), 응답 대기 20 ms, 최대 31대(국번 01~31). 통신 매뉴얼 3.4.7 공장 기본값(속도 2=9600, 패리티 0, 정지 1=2비트)과 같다.","en":"Defaults from user manual 1.5.2 (p.28): 9600 bps, 8 data bits fixed, parity none, 2 stop bits, response wait 20 ms, up to 31 units (01-31); matches comm manual 3.4.7 factory defaults."},{"ko":"매뉴얼은 «400001 (0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(통신 매뉴얼 pp.37-57). 1.1 절 프레임 예시는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «400001 (0000)»: 1-based reference plus hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (pp.37-57). Frame examples in 1.1 show layout only."},{"ko":"통신 설정을 바꾸면 기기를 다시 켜야 정상 동작한다(사용자 매뉴얼 p.28).","en":"Reboot after changing communication settings (user manual p.28)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"000001 (0000)","type":"bit","name":{"ko":"CH1 제어 출력 RUN/STOP","en":"CH1 control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.37 3.1"},{"table":"coils","address":1,"manualAddress":"000002 (0001)","type":"bit","name":{"ko":"CH1 오토튜닝 실행","en":"CH1 auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.37 3.1"},{"table":"coils","address":2,"manualAddress":"000003 (0002)","type":"bit","name":{"ko":"CH2 제어 출력 RUN/STOP","en":"CH2 control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.37 3.1"},{"table":"coils","address":3,"manualAddress":"000004 (0003)","type":"bit","name":{"ko":"CH2 오토튜닝 실행","en":"CH2 auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.37 3.1"},{"table":"coils","address":4,"manualAddress":"000005 (0004)","type":"bit","name":{"ko":"CH3 제어 출력 RUN/STOP","en":"CH3 control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.37 3.1"},{"table":"coils","address":5,"manualAddress":"000006 (0005)","type":"bit","name":{"ko":"CH3 오토튜닝 실행","en":"CH3 auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.37 3.1"},{"table":"coils","address":6,"manualAddress":"000007 (0006)","type":"bit","name":{"ko":"CH4 제어 출력 RUN/STOP","en":"CH4 control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.37 3.1"},{"table":"coils","address":7,"manualAddress":"000008 (0007)","type":"bit","name":{"ko":"CH4 오토튜닝 실행","en":"CH4 auto-tuning execute"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.37 3.1"},{"table":"discrete-inputs","address":0,"manualAddress":"100001 (0000)","type":"bit","name":{"ko":"CH1 출력 LED(OUT)","en":"CH1 output LED (OUT)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":1,"manualAddress":"100002 (0001)","type":"bit","name":{"ko":"CH2 출력 LED(OUT)","en":"CH2 output LED (OUT)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":2,"manualAddress":"100003 (0002)","type":"bit","name":{"ko":"CH3 출력 LED(OUT)","en":"CH3 output LED (OUT)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"discrete-inputs","address":3,"manualAddress":"100004 (0003)","type":"bit","name":{"ko":"CH4 출력 LED(OUT)","en":"CH4 output LED (OUT)"},"access":"r","fc":[2],"ref":"p.38 3.2"},{"table":"input-registers","address":103,"manualAddress":"300104 (0067)","type":"u16","name":{"ko":"소프트웨어 버전","en":"Software version"},"access":"r","fc":[4],"ref":"p.39 3.3"},{"table":"input-registers","address":125,"manualAddress":"300126 (007D)","type":"u16","name":{"ko":"채널 수","en":"Channel quantity"},"access":"r","fc":[4],"ref":"p.39 3.3"},{"table":"input-registers","address":1000,"manualAddress":"301001 (03E8)","type":"s16","name":{"ko":"CH1 현재값 PV","en":"CH1 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1001,"manualAddress":"301002 (03E9)","type":"u16","name":{"ko":"CH1 소수점 위치","en":"CH1 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1002,"manualAddress":"301003 (03EA)","type":"u16","name":{"ko":"CH1 온도 단위","en":"CH1 temperature unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1003,"manualAddress":"301004 (03EB)","type":"s16","name":{"ko":"CH1 설정값 SV(읽기)","en":"CH1 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1004,"manualAddress":"301005 (03EC)","type":"u16","name":{"ko":"CH1 가열 조작량","en":"CH1 heating MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1005,"manualAddress":"301006 (03ED)","type":"u16","name":{"ko":"CH1 냉각 조작량","en":"CH1 cooling MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1006,"manualAddress":"301007 (03EE)","type":"s16","name":{"ko":"CH2 현재값 PV","en":"CH2 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1007,"manualAddress":"301008 (03EF)","type":"u16","name":{"ko":"CH2 소수점 위치","en":"CH2 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1008,"manualAddress":"301009 (03F0)","type":"u16","name":{"ko":"CH2 온도 단위","en":"CH2 temperature unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1009,"manualAddress":"301010 (03F1)","type":"s16","name":{"ko":"CH2 설정값 SV(읽기)","en":"CH2 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1010,"manualAddress":"301011 (03F2)","type":"u16","name":{"ko":"CH2 가열 조작량","en":"CH2 heating MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1011,"manualAddress":"301012 (03F3)","type":"u16","name":{"ko":"CH2 냉각 조작량","en":"CH2 cooling MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1012,"manualAddress":"301013 (03F4)","type":"s16","name":{"ko":"CH3 현재값 PV","en":"CH3 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1013,"manualAddress":"301014 (03F5)","type":"u16","name":{"ko":"CH3 소수점 위치","en":"CH3 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1014,"manualAddress":"301015 (03F6)","type":"u16","name":{"ko":"CH3 온도 단위","en":"CH3 temperature unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1015,"manualAddress":"301016 (03F7)","type":"s16","name":{"ko":"CH3 설정값 SV(읽기)","en":"CH3 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1016,"manualAddress":"301017 (03F8)","type":"u16","name":{"ko":"CH3 가열 조작량","en":"CH3 heating MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1017,"manualAddress":"301018 (03F9)","type":"u16","name":{"ko":"CH3 냉각 조작량","en":"CH3 cooling MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1018,"manualAddress":"301019 (03FA)","type":"s16","name":{"ko":"CH4 현재값 PV","en":"CH4 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1019,"manualAddress":"301020 (03FB)","type":"u16","name":{"ko":"CH4 소수점 위치","en":"CH4 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1020,"manualAddress":"301021 (03FC)","type":"u16","name":{"ko":"CH4 온도 단위","en":"CH4 temperature unit"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.40 3.3"},{"table":"input-registers","address":1021,"manualAddress":"301022 (03FD)","type":"s16","name":{"ko":"CH4 설정값 SV(읽기)","en":"CH4 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.40 3.3"},{"table":"input-registers","address":1022,"manualAddress":"301023 (03FE)","type":"u16","name":{"ko":"CH4 가열 조작량","en":"CH4 heating MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1023,"manualAddress":"301024 (03FF)","type":"u16","name":{"ko":"CH4 냉각 조작량","en":"CH4 cooling MV"},"unit":"%","access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.40 3.3"},{"table":"input-registers","address":1024,"manualAddress":"301025 (0400)","type":"u16","name":{"ko":"표시 상태 비트","en":"Indicator bits"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"CH1 출력 LED","en":"CH1 output LED"},{"bit":1,"ko":"CH2 출력 LED","en":"CH2 output LED"},{"bit":2,"ko":"CH3 출력 LED","en":"CH3 output LED"},{"bit":3,"ko":"CH4 출력 LED","en":"CH4 output LED"}],"ref":"p.41 3.3"},{"table":"input-registers","address":1025,"manualAddress":"301026 (0401)","type":"u16","name":{"ko":"통신 국번","en":"Unit address"},"access":"r","fc":[4],"range":{"min":1,"max":31},"ref":"p.40 3.3"},{"table":"holding-registers","address":0,"manualAddress":"400001 (0000)","type":"s16","name":{"ko":"CH1 설정값 SV","en":"CH1 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"SV 하한~SV 상한. 소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"SV low limit to SV high limit. Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":1,"manualAddress":"400002 (0001)","type":"u16","name":{"ko":"CH1 가열 조작량","en":"CH1 heating MV"},"unit":"%","access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":2,"manualAddress":"400003 (0002)","type":"u16","name":{"ko":"CH1 냉각 조작량","en":"CH1 cooling MV"},"unit":"%","access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 범위 0.0~100.0 %. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.0-100.0 %; raw scaling is not stated in the table."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":3,"manualAddress":"400004 (0003)","type":"u16","name":{"ko":"CH1 자동/수동 제어","en":"CH1 auto/manual control"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"자동(AUTO)","en":"AUTO"},{"value":1,"ko":"수동(MANUAL)","en":"MANUAL"}],"ref":"p.42 3.4.1"},{"table":"holding-registers","address":1000,"manualAddress":"401001 (03E8)","type":"s16","name":{"ko":"CH2 설정값 SV","en":"CH2 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":2000,"manualAddress":"402001 (07D0)","type":"s16","name":{"ko":"CH3 설정값 SV","en":"CH3 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":3000,"manualAddress":"403001 (0BB8)","type":"s16","name":{"ko":"CH4 설정값 SV","en":"CH4 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.42 3.4.1"},{"table":"holding-registers","address":50,"manualAddress":"400051 (0032)","type":"u16","name":{"ko":"CH1 제어 출력 RUN/STOP","en":"CH1 control output RUN/STOP"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.43 3.4.2"},{"table":"holding-registers","address":51,"manualAddress":"400052 (0033)","type":"u16","name":{"ko":"CH1 멀티 SV 번호","en":"CH1 multi SV number"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"SV-0","en":"SV-0"},{"value":1,"ko":"SV-1","en":"SV-1"},{"value":2,"ko":"SV-2","en":"SV-2"},{"value":3,"ko":"SV-3","en":"SV-3"}],"ref":"p.43 3.4.2"},{"table":"holding-registers","address":100,"manualAddress":"400101 (0064)","type":"u16","name":{"ko":"CH1 오토튜닝 실행","en":"CH1 auto-tuning execute"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.43 3.4.2"},{"table":"holding-registers","address":101,"manualAddress":"400102 (0065)","type":"u16","name":{"ko":"CH1 가열 비례대","en":"CH1 heating proportional band"},"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 표기 범위 0.1~999.9 ℃. 원시값 배율은 표에 적혀 있지 않다.","en":"Manual range 0.1-999.9 °C; raw scaling not stated."},"ref":"p.43 3.4.2"},{"table":"holding-registers","address":103,"manualAddress":"400104 (0067)","type":"u16","name":{"ko":"CH1 가열 적분 시간","en":"CH1 heating integral time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.44 3.4.2"},{"table":"holding-registers","address":105,"manualAddress":"400106 (0069)","type":"u16","name":{"ko":"CH1 가열 미분 시간","en":"CH1 heating derivative time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.44 3.4.2"},{"table":"holding-registers","address":150,"manualAddress":"400151 (0096)","type":"u16","name":{"ko":"CH1 입력 종류","en":"CH1 input type"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":26},"description":{"ko":"0 K(CA).H ~ 26 NI12. 코드표는 사용자 매뉴얼 «Input type» 참조.","en":"0 K(CA).H to 26 NI12; code table in the user manual 'Input type'."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":151,"manualAddress":"400152 (0097)","type":"u16","name":{"ko":"CH1 온도 단위","en":"CH1 temperature unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.46 3.4.3"},{"table":"holding-registers","address":152,"manualAddress":"400153 (0098)","type":"s16","name":{"ko":"CH1 입력 보정","en":"CH1 input bias"},"access":"rw","fc":[3,6,16],"description":{"ko":"-999~999(H) / -999.9~999.9(L) digit","en":"-999..999 (H) / -999.9..999.9 (L) digit"},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":154,"manualAddress":"400155 (009A)","type":"s16","name":{"ko":"CH1 SV 하한","en":"CH1 SV low limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":155,"manualAddress":"400156 (009B)","type":"s16","name":{"ko":"CH1 SV 상한","en":"CH1 SV high limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (0: 0, 1: 0.0)."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":156,"manualAddress":"400157 (009C)","type":"u16","name":{"ko":"CH1 제어 출력 동작","en":"CH1 control output mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"가열","en":"Heating"},{"value":1,"ko":"냉각","en":"Cooling"},{"value":2,"ko":"가열·냉각","en":"Heating & cooling"}],"ref":"p.46 3.4.3"},{"table":"holding-registers","address":157,"manualAddress":"400158 (009D)","type":"u16","name":{"ko":"CH1 제어 방식","en":"CH1 control method"},"access":"rw","fc":[3,6,16],"description":{"ko":"가열 또는 냉각: 0 PID, 1 ON/OFF. 가열·냉각: 0 PID-PID, 1 PID-ONOFF, 2 ONOFF-PID, 3 ONOFF-ONOFF.","en":"Heating or cooling: 0 PID, 1 ON/OFF. Heating & cooling: 0 PID-PID, 1 PID-ONOFF, 2 ONOFF-PID, 3 ONOFF-ONOFF."},"ref":"p.46 3.4.3"},{"table":"holding-registers","address":300,"manualAddress":"400301 (012C)","type":"u16","name":{"ko":"통신 속도","en":"Baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"},{"value":5,"ko":"57600 bps","en":"57600 bps"},{"value":6,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":301,"manualAddress":"400302 (012D)","type":"u16","name":{"ko":"패리티","en":"Parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":302,"manualAddress":"400303 (012E)","type":"u16","name":{"ko":"정지 비트","en":"Stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":303,"manualAddress":"400304 (012F)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response waiting time"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.56 3.4.7"},{"table":"holding-registers","address":304,"manualAddress":"400305 (0130)","type":"u16","name":{"ko":"통신 쓰기 허용","en":"Communication write"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"허용","en":"ENABLE"},{"value":1,"ko":"금지","en":"DISABLE"}],"ref":"p.56 3.4.7"},{"table":"holding-registers","address":306,"manualAddress":"400307 (0132)","type":"u16","name":{"ko":"통신 프로토콜","en":"Communication protocol"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RTU","en":"RTU"},{"value":1,"ko":"ASCII","en":"ASCII"}],"ref":"p.57 3.4.7"}],"notes":[{"ko":"TM2 와 TM4 는 보유 레지스터 주소가 다르다(통신 매뉴얼 p.37) — 이 파일은 TM4 전용. 입력 레지스터·코일은 앞부분이 같다.","en":"TM2 and TM4 use different holding addresses (p.37); this file is TM4 only."},{"ko":"보유 레지스터는 CH1 만 적었다. CH2~CH4 는 같은 순서로 +1000(03E8h)씩: 예) CH2 SV 401001(03E8), CH2 RUN/STOP 401051(041A), CH3 오토튜닝 402101(0834) (pp.42-47).","en":"Holding registers list CH1; CH2-CH4 follow at +1000 (03E8h) each, e.g. CH2 SV 401001(03E8), CH2 RUN/STOP 401051(041A), CH3 AT 402101(0834) (pp.42-47)."},{"ko":"통신 단자는 기본 모듈(…B)에만 있다. 확장 모듈(…E)은 기본 모듈 옆에 붙여 쓴다(사용자 매뉴얼 p.18).","en":"Power/comm terminal only on the basic module (…B); expansion modules (…E) attach to it (user manual p.18)."},{"ko":"통신 매뉴얼 TM4 열의 «400119 (00DA)» 는 앞뒤 번호로 보면 오기로 보인다 — 여기선 쓰지 않았다.","en":"The TM4 column entry «400119 (00DA)» looks like a typo; not used here."}],"sources":[{"title":"TM Series Communication Manual MWA-TMC1-V2.2-EN","publisher":"Autonics","edition":{"ko":"MWA-TMC1-V2.2-EN (PDF 작성 2026-08-26)","en":"MWA-TMC1-V2.2-EN (PDF created 2026-08-26)"},"url":"https://www.autonics.com/glb/common/download/528500","pages":{"ko":"pp.37-57 매핑 표 (인쇄 쪽 = PDF 쪽)","en":"pp.37-57 mapping table (printed page = PDF page)"},"checked":"2026-10-22"},{"title":"TM Series User Manual MCT-TMU1-V4.0-EN","publisher":"Autonics","edition":{"ko":"MCT-TMU1-V4.0-EN (PDF 작성 2026-08-19)","en":"MCT-TMU1-V4.0-EN (PDF created 2026-08-19)"},"url":"https://www.autonics.com/glb/common/download/528473","pages":{"ko":"pp.18-19 주문 정보, p.28 통신 인터페이스","en":"pp.18-19 ordering information, p.28 Communication Interface"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/tmh","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"TMH Series","models":["TMH2-22□","TMH2-42□","TMH4-N2□"],"kind":"temperature-controller","title":{"ko":"오토닉스 TMH 고기능 모듈형 2·4채널 PID 온도 조절기 (제어 모듈)","en":"Autonics TMH advanced modular 2/4-channel PID temperature controller (control module)"},"summary":{"ko":"TMH2·TMH4 제어 모듈의 RS485 Modbus RTU 맵. 코일(채널별 RUN/STOP·오토튜닝), 입력 레지스터(채널별 PV·소수점·단위·SV·MV), CH1 보유 레지스터(SV·PID·입력·통신 설정)를 담았다.","en":"RS485 Modbus RTU map of the TMH2/TMH4 control module. Covers coils (per-channel RUN/STOP, auto-tuning), input registers (per-channel PV, decimal point, unit, SV, MV) and CH1 holding registers (SV, PID, input, comm)."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[4800,9600,19200,38400,115200],"dataBits":8,"parity":"none","stopBits":2,"unitRange":[1,32],"notes":[{"ko":"통신 사양: 사용자 매뉴얼 «1.5.2 Communication Interface»(p.33) — 제어 모듈 TMH2/4 는 Modbus RTU, 최대 32대(국번 01~32, TMHC 와 함께 쓰면 01~16), 9600 bps 기본, 데이터 8비트 고정, 패리티 None 기본, 정지 2비트 기본, 응답 대기 20 ms. 국번은 SW1·SW2 스위치로 정한다(출하 국번은 적지 않음).","en":"Comm spec from user manual 1.5.2 (p.33): TMH2/4 control module Modbus RTU, up to 32 units (01-32; 01-16 with TMHC), 9600 bps default, 8 data bits, parity none, 2 stop bits, response wait 20 ms. Address is set by switches SW1/SW2 (no factory unit listed)."},{"ko":"매뉴얼은 «400001(0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(통신 매뉴얼 pp.23-55). 1.1 절 프레임 예시는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «400001(0000)»: 1-based reference plus hex comm address; first entries are (0000), so the parenthesized value is the 0-based wire address (pp.23-55). Frame examples show layout only."},{"ko":"함수 코드: 코일 01·05·15, 입력 접점 02, 입력 레지스터 04, 보유 레지스터 03·06·16 (pp.23-55).","en":"Function codes: coils 01/05/15, discrete inputs 02, input registers 04, holding registers 03/06/16 (pp.23-55)."},{"ko":"통신 설정을 바꾸면 기기를 다시 켜야 정상 동작한다(사용자 매뉴얼 p.33).","en":"Reboot after changing communication settings (user manual p.33)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"000001(0000)","type":"bit","name":{"ko":"CH1 제어 출력 RUN/STOP","en":"CH1 control output RUN/STOP"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.23 2.1.1"},{"table":"coils","address":1,"manualAddress":"000002(0001)","type":"bit","name":{"ko":"CH2 제어 출력 RUN/STOP","en":"CH2 control output RUN/STOP"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.23 2.1.1"},{"table":"coils","address":2,"manualAddress":"000003(0002)","type":"bit","name":{"ko":"CH3 제어 출력 RUN/STOP (TMH4 만)","en":"CH3 control output RUN/STOP (TMH4 only)"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.23 2.1.1"},{"table":"coils","address":3,"manualAddress":"000004(0003)","type":"bit","name":{"ko":"CH4 제어 출력 RUN/STOP (TMH4 만)","en":"CH4 control output RUN/STOP (TMH4 only)"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.23 2.1.1"},{"table":"coils","address":4,"manualAddress":"000005(0004)","type":"bit","name":{"ko":"CH1 오토튜닝 실행","en":"CH1 auto-tuning execute"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 2.1.1"},{"table":"coils","address":5,"manualAddress":"000006(0005)","type":"bit","name":{"ko":"CH2 오토튜닝 실행","en":"CH2 auto-tuning execute"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 2.1.1"},{"table":"coils","address":6,"manualAddress":"000007(0006)","type":"bit","name":{"ko":"CH3 오토튜닝 실행 (TMH4 만)","en":"CH3 auto-tuning execute (TMH4 only)"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 2.1.1"},{"table":"coils","address":7,"manualAddress":"000008(0007)","type":"bit","name":{"ko":"CH4 오토튜닝 실행 (TMH4 만)","en":"CH4 auto-tuning execute (TMH4 only)"},"access":"rw","fc":[1,5,15],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 2.1.1"},{"table":"input-registers","address":1000,"manualAddress":"301001(03E8)","type":"s16","name":{"ko":"CH1 현재값 PV","en":"CH1 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.28 2.1.3"},{"table":"input-registers","address":1001,"manualAddress":"301002(03E9)","type":"s16","name":{"ko":"CH2 현재값 PV","en":"CH2 present value (PV)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.28 2.1.3"},{"table":"input-registers","address":1002,"manualAddress":"301003(03EA)","type":"s16","name":{"ko":"CH3 현재값 PV (TMH4 만)","en":"CH3 present value (PV) (TMH4 only)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.28 2.1.3"},{"table":"input-registers","address":1003,"manualAddress":"301004(03EB)","type":"s16","name":{"ko":"CH4 현재값 PV (TMH4 만)","en":"CH4 present value (PV) (TMH4 only)"},"access":"r","fc":[4],"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.28 2.1.3"},{"table":"input-registers","address":1004,"manualAddress":"301005(03EC)","type":"u16","name":{"ko":"CH1 소수점 위치","en":"CH1 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.28 2.1.3"},{"table":"input-registers","address":1005,"manualAddress":"301006(03ED)","type":"u16","name":{"ko":"CH2 소수점 위치","en":"CH2 decimal point"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.28 2.1.3"},{"table":"input-registers","address":1006,"manualAddress":"301007(03EE)","type":"u16","name":{"ko":"CH3 소수점 위치 (TMH4 만)","en":"CH3 decimal point (TMH4 only)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.28 2.1.3"},{"table":"input-registers","address":1007,"manualAddress":"301008(03EF)","type":"u16","name":{"ko":"CH4 소수점 위치 (TMH4 만)","en":"CH4 decimal point (TMH4 only)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.28 2.1.3"},{"table":"input-registers","address":1008,"manualAddress":"301009(03F0)","type":"u16","name":{"ko":"CH1 온도 단위","en":"CH1 temperature unit"},"access":"r","fc":[4],"description":{"ko":"온도 입력: 0 ℃, 1 ℉ / 아날로그 입력: 0 OFF, 1 ℃, 2 ℉, 3 %","en":"Temperature input: 0 °C, 1 °F / analog input: 0 OFF, 1 °C, 2 °F, 3 %"},"ref":"p.28 2.1.3"},{"table":"input-registers","address":1009,"manualAddress":"301010(03F1)","type":"u16","name":{"ko":"CH2 온도 단위","en":"CH2 temperature unit"},"access":"r","fc":[4],"description":{"ko":"온도 입력: 0 ℃, 1 ℉ / 아날로그 입력: 0 OFF, 1 ℃, 2 ℉, 3 %","en":"Temperature input: 0 °C, 1 °F / analog input: 0 OFF, 1 °C, 2 °F, 3 %"},"ref":"p.28 2.1.3"},{"table":"input-registers","address":1010,"manualAddress":"301011(03F2)","type":"u16","name":{"ko":"CH3 온도 단위 (TMH4 만)","en":"CH3 temperature unit (TMH4 only)"},"access":"r","fc":[4],"description":{"ko":"온도 입력: 0 ℃, 1 ℉ / 아날로그 입력: 0 OFF, 1 ℃, 2 ℉, 3 %","en":"Temperature input: 0 °C, 1 °F / analog input: 0 OFF, 1 °C, 2 °F, 3 %"},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1011,"manualAddress":"301012(03F3)","type":"u16","name":{"ko":"CH4 온도 단위 (TMH4 만)","en":"CH4 temperature unit (TMH4 only)"},"access":"r","fc":[4],"description":{"ko":"온도 입력: 0 ℃, 1 ℉ / 아날로그 입력: 0 OFF, 1 ℃, 2 ℉, 3 %","en":"Temperature input: 0 °C, 1 °F / analog input: 0 OFF, 1 °C, 2 °F, 3 %"},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1012,"manualAddress":"301013(03F4)","type":"s16","name":{"ko":"CH1 설정값 SV(읽기)","en":"CH1 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1013,"manualAddress":"301014(03F5)","type":"s16","name":{"ko":"CH2 설정값 SV(읽기)","en":"CH2 set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1014,"manualAddress":"301015(03F6)","type":"s16","name":{"ko":"CH3 설정값 SV(읽기) (TMH4 만)","en":"CH3 set value SV (read) (TMH4 only)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1015,"manualAddress":"301016(03F7)","type":"s16","name":{"ko":"CH4 설정값 SV(읽기) (TMH4 만)","en":"CH4 set value SV (read) (TMH4 only)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1016,"manualAddress":"301017(03F8)","type":"u16","name":{"ko":"CH1 가열 조작량","en":"CH1 heating MV"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1017,"manualAddress":"301018(03F9)","type":"u16","name":{"ko":"CH2 가열 조작량","en":"CH2 heating MV"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1018,"manualAddress":"301019(03FA)","type":"u16","name":{"ko":"CH3 가열 조작량 (TMH4 만)","en":"CH3 heating MV (TMH4 only)"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1019,"manualAddress":"301020(03FB)","type":"u16","name":{"ko":"CH4 가열 조작량 (TMH4 만)","en":"CH4 heating MV (TMH4 only)"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.29 2.1.3"},{"table":"input-registers","address":1020,"manualAddress":"301021(03FC)","type":"u16","name":{"ko":"CH1 냉각 조작량","en":"CH1 cooling MV"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":100},"ref":"p.29 2.1.3"},{"table":"input-registers","address":103,"manualAddress":"300104(0067)","type":"u16","name":{"ko":"소프트웨어 버전","en":"Software version"},"access":"r","fc":[4],"ref":"p.26 2.1.3"},{"table":"input-registers","address":125,"manualAddress":"300126(007D)","type":"u16","name":{"ko":"채널 수","en":"Channel quantity"},"access":"r","fc":[4],"values":[{"value":2,"ko":"TMH2","en":"TMH2"},{"value":4,"ko":"TMH4","en":"TMH4"}],"ref":"p.26 2.1.3"},{"table":"holding-registers","address":0,"manualAddress":"400001(0000)","type":"s16","name":{"ko":"CH1 설정값 SV","en":"CH1 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"SV 하한~SV 상한. 소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"SV low limit to SV high limit. Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":1,"manualAddress":"400002(0001)","type":"u16","name":{"ko":"CH1 가열 조작량","en":"CH1 heating MV"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":2,"manualAddress":"400003(0002)","type":"u16","name":{"ko":"CH1 냉각 조작량","en":"CH1 cooling MV"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":3,"manualAddress":"400004(0003)","type":"u16","name":{"ko":"CH1 자동/수동 제어","en":"CH1 auto/manual control"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"자동(AUTO)","en":"AUTO"},{"value":1,"ko":"수동(MANUAL)","en":"MANUAL"}],"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":1000,"manualAddress":"401001(03E8)","type":"s16","name":{"ko":"CH2 설정값 SV","en":"CH2 set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":2000,"manualAddress":"402001(07D0)","type":"s16","name":{"ko":"CH3 설정값 SV (TMH4 만)","en":"CH3 set value (SV) (TMH4 only)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":3000,"manualAddress":"403001(0BB8)","type":"s16","name":{"ko":"CH4 설정값 SV (TMH4 만)","en":"CH4 set value (SV) (TMH4 only)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.34 2.1.4.1"},{"table":"holding-registers","address":50,"manualAddress":"400051(0032)","type":"u16","name":{"ko":"CH1 제어 출력 RUN/STOP","en":"CH1 control output RUN/STOP"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.35 2.1.4.2"},{"table":"holding-registers","address":51,"manualAddress":"400052(0033)","type":"u16","name":{"ko":"CH1 멀티 SV 번호","en":"CH1 multi SV number"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"SV-0","en":"SV-0"},{"value":1,"ko":"SV-1","en":"SV-1"},{"value":2,"ko":"SV-2","en":"SV-2"},{"value":3,"ko":"SV-3","en":"SV-3"}],"ref":"p.35 2.1.4.2"},{"table":"holding-registers","address":52,"manualAddress":"400053(0034)","type":"s16","name":{"ko":"CH1 SV-0 설정값","en":"CH1 SV-0 set value"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 위치는 해당 채널 소수점 레지스터(301005~, 0: 0, 1: 0.0)를 따른다.","en":"Decimal point per the channel's dot register (301005-, 0: 0, 1: 0.0)."},"ref":"p.35 2.1.4.2"},{"table":"holding-registers","address":100,"manualAddress":"400101(0064)","type":"u16","name":{"ko":"CH1 오토튜닝 실행","en":"CH1 auto-tuning execute"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":101,"manualAddress":"400102(0065)","type":"u16","name":{"ko":"CH1 가열 비례대","en":"CH1 heating proportional band"},"scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":999.9},"description":{"ko":"원시 1~9999 = 0.1~999.9, 단위 ℃/℉/%F.S.","en":"Raw 1-9999 = 0.1-999.9, unit °C/°F/%F.S."},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":102,"manualAddress":"400103(0066)","type":"u16","name":{"ko":"CH1 냉각 비례대","en":"CH1 cooling proportional band"},"scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":999.9},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":103,"manualAddress":"400104(0067)","type":"u16","name":{"ko":"CH1 가열 적분 시간","en":"CH1 heating integral time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":104,"manualAddress":"400105(0068)","type":"u16","name":{"ko":"CH1 냉각 적분 시간","en":"CH1 cooling integral time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":105,"manualAddress":"400106(0069)","type":"u16","name":{"ko":"CH1 가열 미분 시간","en":"CH1 heating derivative time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":106,"manualAddress":"400107(006A)","type":"u16","name":{"ko":"CH1 냉각 미분 시간","en":"CH1 cooling derivative time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":108,"manualAddress":"400109(006C)","type":"u16","name":{"ko":"CH1 수동 리셋","en":"CH1 manual reset"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.36 2.1.4.3"},{"table":"holding-registers","address":150,"manualAddress":"400151(0096)","type":"u16","name":{"ko":"CH1 입력 종류","en":"CH1 input type"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":32},"description":{"ko":"0 K(CA).H ~ 32 4-20 mA","en":"0 K(CA).H to 32 4-20 mA"},"ref":"p.41 2.1.4.4"},{"table":"holding-registers","address":151,"manualAddress":"400152(0097)","type":"u16","name":{"ko":"CH1 온도 단위","en":"CH1 unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.41 2.1.4.4"},{"table":"holding-registers","address":154,"manualAddress":"400155(009A)","type":"u16","name":{"ko":"CH1 스케일 소수점","en":"CH1 scale decimal point"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"},{"value":2,"ko":"0.00","en":"0.00"},{"value":3,"ko":"0.000","en":"0.000"}],"ref":"p.41 2.1.4.4"},{"table":"holding-registers","address":155,"manualAddress":"400156(009B)","type":"s16","name":{"ko":"CH1 스케일 하한 표시값","en":"CH1 low-limit scale value"},"access":"rw","fc":[3,6,16],"range":{"min":-9999,"max":9999},"ref":"p.41 2.1.4.4"},{"table":"holding-registers","address":156,"manualAddress":"400157(009C)","type":"s16","name":{"ko":"CH1 스케일 상한 표시값","en":"CH1 high-limit scale value"},"access":"rw","fc":[3,6,16],"range":{"min":-9999,"max":9999},"ref":"p.41 2.1.4.4"},{"table":"holding-registers","address":160,"manualAddress":"400161(00A0)","type":"s16","name":{"ko":"CH1 입력 보정","en":"CH1 input bias"},"access":"rw","fc":[3,6,16],"description":{"ko":"Temp.H·아날로그 -999~999, Temp.L -9999~9999(-999.9~999.9)","en":"Temp.H/analog -999..999, Temp.L -9999..9999 (-999.9..999.9)"},"ref":"p.41 2.1.4.4"},{"table":"holding-registers","address":400,"manualAddress":"400401(0190)","type":"u16","name":{"ko":"통신 속도","en":"Bit per second"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"4800 bps","en":"4800 bps"},{"value":1,"ko":"9600 bps","en":"9600 bps"},{"value":2,"ko":"19200 bps","en":"19200 bps"},{"value":3,"ko":"38400 bps","en":"38400 bps"},{"value":4,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.54 2.1.4.8"},{"table":"holding-registers","address":401,"manualAddress":"400402(0191)","type":"u16","name":{"ko":"패리티","en":"Parity bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"p.54 2.1.4.8"},{"table":"holding-registers","address":402,"manualAddress":"400403(0192)","type":"u16","name":{"ko":"정지 비트","en":"Stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"p.54 2.1.4.8"},{"table":"holding-registers","address":403,"manualAddress":"400404(0193)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response waiting time"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.54 2.1.4.8"},{"table":"holding-registers","address":404,"manualAddress":"400405(0194)","type":"u16","name":{"ko":"통신 쓰기 허용","en":"Communication write"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"허용","en":"ENABLE"},{"value":1,"ko":"금지","en":"DISABLE"}],"ref":"p.54 2.1.4.8"},{"table":"holding-registers","address":412,"manualAddress":"400413(019C)","type":"u16","name":{"ko":"CH1 경보 리셋","en":"CH1 alarm reset"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"NO","en":"NO"},{"value":1,"ko":"YES","en":"YES"}],"ref":"p.54 2.1.4.8"}],"notes":[{"ko":"통신 매뉴얼은 «TMH2 와 TMH4 의 파라미터 주소가 다르다» 고 적지만, 여기 담은 항목은 두 열의 주소가 같다 — TMH2 에는 CH3·CH4 칸이 없다(«-»).","en":"The manual says TMH2 and TMH4 addresses differ, but the entries included here have the same address in both columns; TMH2 simply lacks CH3/CH4 ('-')."},{"ko":"보유 레지스터는 CH1 만 적었다. CH2~CH4 는 같은 순서로 +1000(03E8h)씩: 예) CH2 RUN/STOP 401051(041A), CH3 오토튜닝 402101(0834), CH2 공통 그룹 401401(0578) (pp.34-55).","en":"Holding registers list CH1; CH2-CH4 follow at +1000 (03E8h), e.g. CH2 RUN/STOP 401051(041A), CH3 AT 402101(0834), CH2 common group 401401(0578) (pp.34-55)."},{"ko":"옵션 모듈(TMHA 아날로그·TMHE 디지털 입력/경보·TMHCT CT 입력)과 통신 모듈 TMHC 는 별도 맵(통신 매뉴얼 2.2~2.6 절) — 여기선 제어 모듈만.","en":"Option modules (TMHA, TMHE, TMHCT) and the TMHC communication module have separate maps (sections 2.2-2.6); only the control module is covered."},{"ko":"models 의 □ 는 제어 출력(R 릴레이·S SSR·C 전류/SSR), 스크루리스 단자 모델은 끝에 L 이 붙는다 (사용자 매뉴얼 p.20).","en":"□ = control output (R relay, S SSR, C current/SSR); screwless-terminal models add L (user manual p.20)."}],"sources":[{"title":"TMH Series Communication Manual MCT-TMHC-V3.5-EN","publisher":"Autonics","edition":{"ko":"MCT-TMHC-V3.5-EN (PDF 작성 2026-04-21)","en":"MCT-TMHC-V3.5-EN (PDF created 2026-04-21)"},"url":"https://www.autonics.com/glb/common/download/524686","pages":{"ko":"pp.23-55 «2.1 TMH2/4 Series [Control module]» (인쇄 쪽 = PDF 쪽)","en":"pp.23-55 '2.1 TMH2/4 Series [Control module]' (printed page = PDF page)"},"checked":"2026-10-22"},{"title":"TMH Series User Manual MCT-TMHU-V3.6-EN","publisher":"Autonics","edition":{"ko":"MCT-TMHU-V3.6-EN (PDF 작성 2026-08-14)","en":"MCT-TMHU-V3.6-EN (PDF created 2026-08-14)"},"url":"https://www.autonics.com/glb/common/download/528475","pages":{"ko":"p.20 주문 정보, p.33 통신 인터페이스","en":"p.20 ordering information, p.33 Communication Interface"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"autonics/tx4","manufacturer":{"ko":"오토닉스","en":"Autonics"},"model":"TX Series","models":["TX4S","TX4M","TX4W","TX4H","TX4L","TX4N"],"kind":"temperature-controller","title":{"ko":"오토닉스 TX 시리즈 PID 온도 조절기 (RS485 모델)","en":"Autonics TX Series PID temperature controller (RS485 models)"},"summary":{"ko":"LCD 표시 단일 출력 PID 온도 조절기. 옵션 T·B 모델만 RS485 Modbus RTU. 코일(RUN/STOP·AT·경보 해제), 입력 레지스터(PV·SV·표시 상태), 보유 레지스터(SV·PID·입력·경보·통신)를 담았다.","en":"Single-output PID temperature controller. Only option T/B models have RS485 Modbus RTU. Covers coils (RUN/STOP, AT, alarm reset), input registers (PV, SV, indicators) and holding registers (SV, PID, input, alarm, comm)."},"protocols":["rtu"],"comm":{"addressing":"zero","baud":9600,"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,127],"notes":[{"ko":"통신 기본값: 통신 매뉴얼 p.31 (ADRS 기본 1·범위 1~127, BPS 기본 2=9600, PRTY 기본 NONE, STP 기본 2, 응답 대기 20 ms). 데이터 8비트 고정·지원 속도는 제품 매뉴얼(TCD250010AE) p.2 «Communication Interface».","en":"Defaults from comm manual p.31 (ADRS 1, range 1-127; BPS 2=9600; NONE; stop 2; 20 ms). 8 data bits fixed and speed list from product manual TCD250010AE p.2."},{"ko":"매뉴얼은 «400001 (0000)» 꼴 — 1 기준 참조 번호 + 괄호 안 16진 통신 주소. 각 표 첫 항목이 (0000) 이라 괄호 값을 0 기준 프레임 주소로 썼다(통신 매뉴얼 p.23~31). 프레임 예시(p.12~20)는 바이트 자리만 있고 숫자 예는 없다.","en":"Manual writes «400001 (0000)»: 1-based reference + hex comm address; first entries are (0000), so the parenthesized value is used as the 0-based wire address (pp.23-31). Frame examples show layout only."}]},"registers":[{"table":"coils","address":0,"manualAddress":"000001 (0000)","type":"bit","name":{"ko":"제어 출력 RUN/STOP","en":"Control output RUN/STOP"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"RUN","en":"RUN"},{"value":1,"ko":"STOP","en":"STOP"}],"ref":"p.23 표 2.1","source":0},{"table":"coils","address":1,"manualAddress":"000002 (0001)","type":"bit","name":{"ko":"오토튜닝 실행/정지","en":"Auto-tuning run/stop"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 표 2.1","source":0},{"table":"coils","address":2,"manualAddress":"000003 (0002)","type":"bit","name":{"ko":"경보 출력 해제","en":"Alarm output reset"},"access":"rw","fc":[1,5],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.23 표 2.1","source":0},{"table":"input-registers","address":1000,"manualAddress":"301001 (03E8)","type":"s16","name":{"ko":"현재값 PV","en":"Present value (PV)"},"access":"r","fc":[4],"range":{"min":-1999,"max":9999},"values":[{"value":31000,"ko":"OPEN(센서 단선)","en":"OPEN"},{"value":30000,"ko":"HHHH(상한 초과)","en":"HHHH (high)"},{"value":-30000,"ko":"LLLL(하한 미만)","en":"LLLL (low)"}],"description":{"ko":"소수점 위치는 입력 설정에 따름 — 소수점 레지스터 301002(03E9) 참조.","en":"Decimal point depends on input type — see 301002(03E9)."},"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1001,"manualAddress":"301002 (03E9)","type":"u16","name":{"ko":"소수점 위치 (DOT)","en":"Decimal point (DOT)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0","en":"0"},{"value":1,"ko":"0.0","en":"0.0"}],"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1002,"manualAddress":"301003 (03EA)","type":"u16","name":{"ko":"표시 단위 (UNIT)","en":"Display unit (UNIT)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1003,"manualAddress":"301004 (03EB)","type":"s16","name":{"ko":"설정값 SV(읽기)","en":"Set value SV (read)"},"access":"r","fc":[4],"description":{"ko":"L-SV~H-SV 안. 소수점 위치는 입력 설정에 따름(301002).","en":"Within L-SV..H-SV. Decimal point per input type (301002)."},"ref":"p.26 표 2.3","source":0},{"table":"input-registers","address":1004,"manualAddress":"301005 (03EC)","type":"u16","name":{"ko":"전면 표시등 상태 비트","en":"Front indicator bits"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"℃ 표시등","en":"°C indicator"},{"bit":1,"ko":"℉ 표시등","en":"°F indicator"},{"bit":2,"ko":"제어 출력(OUT)","en":"OUT indicator"},{"bit":3,"ko":"오토튜닝(AT)","en":"AT indicator"},{"bit":4,"ko":"경보 출력 1(AL1)","en":"AL1 indicator"},{"bit":5,"ko":"경보 출력 2(AL2)","en":"AL2 indicator"}],"ref":"p.26 표 2.3, p.27 «Bit data consistence of 301005 (03EC)»","source":0},{"table":"holding-registers","address":0,"manualAddress":"400001 (0000)","type":"s16","name":{"ko":"설정값 SV","en":"Set value (SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"L-SV~H-SV 안. 소수점 위치는 입력 설정에 따름(입력 레지스터 301002).","en":"Within L-SV..H-SV. Decimal point per input type (input reg 301002)."},"ref":"p.28 표 2.4.1","source":0},{"table":"holding-registers","address":50,"manualAddress":"400051(0032)","type":"s16","name":{"ko":"경보 1 설정 (AL1)","en":"Alarm 1 setting (AL1)"},"access":"rw","fc":[3,6,16],"description":{"ko":"편차 경보: -F.S.~F.S., 절대값 경보: 온도 범위 안. 소수점은 입력 설정에 따름.","en":"Deviation: -F.S..F.S.; absolute: within temperature range. Decimal per input type."},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":51,"manualAddress":"400052(0033)","type":"s16","name":{"ko":"경보 2 설정 (AL2)","en":"Alarm 2 setting (AL2)"},"access":"rw","fc":[3,6,16],"description":{"ko":"편차 경보: -F.S.~F.S., 절대값 경보: 온도 범위 안. 소수점은 입력 설정에 따름.","en":"Deviation: -F.S..F.S.; absolute: within temperature range. Decimal per input type."},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":52,"manualAddress":"400053(0034)","type":"u16","name":{"ko":"오토튜닝 (AT)","en":"Auto-tuning (AT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":53,"manualAddress":"400054(0035)","type":"u16","name":{"ko":"비례대 (P)","en":"Proportional band (P)"},"scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":999.9},"description":{"ko":"원시 1~9999 = 0.1~999.9 ℃/℉.","en":"Raw 1-9999 = 0.1-999.9 °C/°F."},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":54,"manualAddress":"400055(0036)","type":"u16","name":{"ko":"적분 시간 (I)","en":"Integral time (I)"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":55,"manualAddress":"400056(0037)","type":"u16","name":{"ko":"미분 시간 (D)","en":"Derivative time (D)"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":56,"manualAddress":"400057(0038)","type":"u16","name":{"ko":"수동 리셋 (REST)","en":"Manual reset (REST)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":57,"manualAddress":"400058(0039)","type":"u16","name":{"ko":"히스테리시스 (HYS)","en":"Hysteresis (HYS)"},"access":"rw","fc":[3,6,16],"description":{"ko":"1~100 (소수점 없는 입력) 또는 1~500 = 0.1~50.0 (0.1 입력). 배율은 입력 설정에 따름.","en":"1-100 (integer input) or 1-500 = 0.1-50.0 (0.1 input). Scaling follows input type."},"ref":"p.29 표 2.4.2","source":0},{"table":"holding-registers","address":100,"manualAddress":"400101(0064)","type":"u16","name":{"ko":"입력 센서 (IN-T)","en":"Input sensor (IN-T)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"K(CA) 1℃ 단위 KCA.H","en":"K (CA), 1 digit, KCA.H"},{"value":1,"ko":"K(CA) 0.1℃ 단위 KCA.L","en":"K (CA), 0.1, KCA.L"},{"value":2,"ko":"J(IC) 1 JIC.H","en":"J (IC), 1, JIC.H"},{"value":3,"ko":"J(IC) 0.1 JIC.L","en":"J (IC), 0.1, JIC.L"},{"value":4,"ko":"L(IC) 1 LIC.H","en":"L (IC), 1, LIC.H"},{"value":5,"ko":"L(IC) 0.1 LIC.L","en":"L (IC), 0.1, LIC.L"},{"value":6,"ko":"T(CC) 1 TCC.H","en":"T (CC), 1, TCC.H"},{"value":7,"ko":"T(CC) 0.1 TCC.L","en":"T (CC), 0.1, TCC.L"},{"value":8,"ko":"R(PR) 1 RPR","en":"R (PR), 1, RPR"},{"value":9,"ko":"S(PR) 1 SPR","en":"S (PR), 1, SPR"},{"value":10,"ko":"DPt100Ω 1 DPT.H","en":"DPt100, 1, DPT.H"},{"value":11,"ko":"DPt100Ω 0.1 DPT.L","en":"DPt100, 0.1, DPT.L"},{"value":12,"ko":"Cu50Ω 1 CUS.H","en":"Cu50, 1, CUS.H"},{"value":13,"ko":"Cu50Ω 0.1 CUS.L","en":"Cu50, 0.1, CUS.L"}],"description":{"ko":"값마다 소수점(1 또는 0.1)이 정해진다 — PV·SV 등 온도 값 배율이 이걸 따른다.","en":"Each code fixes the decimal (1 or 0.1); temperature values follow it."},"ref":"p.30 표 2.4.3, p.32 Table 1","source":0},{"table":"holding-registers","address":101,"manualAddress":"400102(0065)","type":"u16","name":{"ko":"온도 단위 (UNIT)","en":"Temperature unit (UNIT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":102,"manualAddress":"400103(0066)","type":"s16","name":{"ko":"입력 보정 (IN-B)","en":"Input correction (IN-B)"},"access":"rw","fc":[3,6,16],"description":{"ko":"-999~999, 0.1 입력이면 원시 -1999~9999 = -199.9~999.9. 배율은 입력 설정에 따름.","en":"-999..999; with 0.1 input raw -1999..9999 = -199.9..999.9. Scaling follows input type."},"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":103,"manualAddress":"400104(0067)","type":"u16","name":{"ko":"입력 디지털 필터 (MAV.F)","en":"Input digital filter (MAV.F)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":120},"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":104,"manualAddress":"400105(0068)","type":"s16","name":{"ko":"SV 하한 (L-SV)","en":"SV low limit (L-SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"범위는 입력 종류 표(p.32)를 따름. 소수점은 입력 설정에 따름.","en":"Range per input type table (p.32); decimal per input type."},"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":105,"manualAddress":"400106(0069)","type":"s16","name":{"ko":"SV 상한 (H-SV)","en":"SV high limit (H-SV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"범위는 입력 종류 표(p.32)를 따름. 소수점은 입력 설정에 따름.","en":"Range per input type table (p.32); decimal per input type."},"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":106,"manualAddress":"400107(006A)","type":"u16","name":{"ko":"제어 출력 모드 (O-FT)","en":"Control output mode (O-FT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"가열","en":"HEAT"},{"value":1,"ko":"냉각","en":"COOL"}],"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":107,"manualAddress":"400108(006B)","type":"u16","name":{"ko":"제어 방식 (C-MD)","en":"Control method (C-MD)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"PID","en":"PID"},{"value":1,"ko":"ON/OFF","en":"ON/OFF"}],"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":111,"manualAddress":"400112(006F)","type":"u16","name":{"ko":"제어 주기 (T)","en":"Control cycle (T)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.5,"max":120},"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":112,"manualAddress":"400113(0070)","type":"u16","name":{"ko":"경보 1 동작 (AL-1)","en":"Alarm 1 operation (AL-1)"},"access":"rw","fc":[3,6,16],"description":{"ko":"경보 1 동작 방식 코드(매뉴얼 Table 2, pp.33-34). 레지스터 값과 표 표기의 대응이 매뉴얼에서 분명하지 않아 값 뜻은 넣지 않았다.","en":"Alarm 1 mode code (manual Table 2, pp.33-34). How the register value maps to the table notation is not explicit in the manual, so value meanings are omitted."},"ref":"p.30 표 2.4.3, pp.33-34 Table 2","source":0},{"table":"holding-registers","address":113,"manualAddress":"400114(0071)","type":"u16","name":{"ko":"경보 2 동작 (AL-2)","en":"Alarm 2 operation (AL-2)"},"access":"rw","fc":[3,6,16],"description":{"ko":"코드는 AL-1 과 같다(Table 2, 16진). 공장 기본 «20: AM2.A» = 0x20.","en":"Same codes as AL-1 (Table 2, hex). Default «20: AM2.A» = 0x20."},"ref":"p.30 표 2.4.3","source":0},{"table":"holding-registers","address":119,"manualAddress":"400120(0077)","type":"u16","name":{"ko":"통신 국번 (ADRS)","en":"Comm address (ADRS)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":127},"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":120,"manualAddress":"400121(0078)","type":"u16","name":{"ko":"통신 속도 (BPS)","en":"Comm speed (BPS)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"}],"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":121,"manualAddress":"400122(0079)","type":"u16","name":{"ko":"패리티 (PRTY)","en":"Parity (PRTY)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"NONE"},{"value":1,"ko":"짝수","en":"EVEN"},{"value":2,"ko":"홀수","en":"ODD"}],"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":122,"manualAddress":"400123(007A)","type":"u16","name":{"ko":"정지 비트 (STP)","en":"Stop bit (STP)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 bit"},{"value":1,"ko":"2비트","en":"2 bits"}],"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":123,"manualAddress":"400124(007B)","type":"u16","name":{"ko":"응답 대기 시간 (RSW.T)","en":"Response waiting time (RSW.T)"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":124,"manualAddress":"400125(007C)","type":"u16","name":{"ko":"통신 쓰기 허용 (COMW)","en":"Comm write enable (COMW)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"허용(EN.A)","en":"Enabled (EN.A)"},{"value":1,"ko":"금지(DIS.A)","en":"Disabled (DIS.A)"}],"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":125,"manualAddress":"400126(007D)","type":"u16","name":{"ko":"디지털 입력 키 (DI-K)","en":"Digital input key (DI-K)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"STOP","en":"STOP"},{"value":2,"ko":"경보 해제(AL.RE)","en":"Alarm reset (AL.RE)"},{"value":3,"ko":"오토튜닝(AT)","en":"AT"}],"ref":"p.31 표 2.4.3","source":0},{"table":"holding-registers","address":127,"manualAddress":"400128(007F)","type":"u16","name":{"ko":"잠금 (LOC)","en":"Lock (LOC)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"LOC1","en":"LOC1"},{"value":2,"ko":"LOC2","en":"LOC2"},{"value":3,"ko":"LOC3","en":"LOC3"}],"ref":"p.31 표 2.4.3","source":0}],"notes":[{"ko":"RS485 는 옵션 T(경보1+RS485)·B(경보1+경보2+RS485) 모델만(제품 매뉴얼 p.2 주문 정보). 주문표는 모든 크기·옵션 조합이 있지는 않다고 적는다 — models 목록은 시리즈 크기이며 크기별 RS485 유무는 확인하지 않았다.","en":"RS485 only on option T (AL1+RS485) and B (AL1+AL2+RS485) models (product manual p.2). Not all size/option combinations exist; per-size RS485 availability not verified."},{"ko":"입력 접점(1x) 100001(0000)~100006(0005) 은 입력 레지스터 301005 비트 0~5 와 같은 항목·순서다(p.24) — 레지스터 쪽만 넣었다.","en":"Discrete inputs 100001(0000)-100006(0005) mirror bits 0-5 of input reg 301005 (p.24); only the register is included."},{"ko":"온도 값(PV·SV·경보·L-SV·H-SV·IN-B)의 소수점은 IN-T(400101) 가 0.1 형이면 한 자리 — 301002 로 확인.","en":"Temperature values have one decimal when IN-T is a 0.1 type — check 301002."}],"sources":[{"title":"TX Series Communication Manual MCT-TXC1-V1.7_EN","publisher":"Autonics","edition":{"ko":"MCT-TXC1-V1.7_EN (PDF 작성 2026-07-10)","en":"MCT-TXC1-V1.7_EN (PDF created 2026-07-10)"},"url":"https://www.autonics.com/glb/common/download/526426","pages":{"ko":"pp.23-34 (인쇄 쪽 = PDF 쪽)","en":"pp.23-34 (printed page = PDF page)"},"checked":"2026-10-19"},{"title":"LCD PID Temperature Controllers TX Series PRODUCT MANUAL TCD250010AE","publisher":"Autonics","edition":{"ko":"TX_EN_TCD250010AE_20260715","en":"TX_EN_TCD250010AE_20260715"},"url":"https://www.autonics.com/glb/common/download/526424","pages":{"ko":"p.2 주문 정보·Communication Interface","en":"p.2 ordering information, Communication Interface"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"eastron/sdm120ct-40ma","manufacturer":{"ko":"이스트론","en":"Eastron"},"model":"SDM120CT-40mA","kind":"power-meter","title":{"ko":"이스트론 SDM120CT-40mA 단상 DIN 레일 다기능 전력량계(40 mA 2차 CT)","en":"Eastron SDM120CT-40mA single-phase DIN-rail multifunction meter (40 mA secondary CT)"},"summary":{"ko":"단상 계측값은 input register(FC04)에 IEEE 754 Float32(상위 워드 먼저), 설정은 holding register(FC03 읽기·FC16 쓰기). 일부 설정(F9xx)은 2바이트 한 칸.","en":"Single-phase measurements are IEEE 754 Float32 input registers (FC04, high word first); settings are holding registers (FC03 read, FC16 write). Some settings (F9xx) are single 2-byte registers."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600],"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"order":"ABCD","addressing":"plc","notes":[{"ko":"매뉴얼은 30001·40001 꼴 번호와 Hex 시작 주소 칸을 함께 적는다(30001 ↔ 00 00, 40003 ↔ 00 02). 통신 주소 = 번호 − 30001·− 40001, 6자리(461457·463761 등)는 − 400001 (p.16-19).","en":"The manual lists 30001/40001-style numbers with a Hex start-address column (30001 ↔ 00 00, 40003 ↔ 00 02). Wire address = number − 30001 / − 40001; 6-digit numbers (461457, 463761 …) use − 400001 (p.16-19)."},{"ko":"주소 기준은 프레임 예로 확인: 30001 L1 전압 읽기 01 04 00 00 00 02 71 CB → 01 04 04 43 66 00 00 0E 1F(230.0) (p.16-17), 40003 읽기 01 03 00 02 00 02 65 CB → 01 03 04 42 70 00 00 EF 90(60.0), 15분 쓰기 01 10 00 02 00 02 04 41 70 00 00 67 91 → 01 10 00 02 00 02 E0 08 (p.19-20). 여섯 프레임 모두 CRC 를 다시 계산해 맞음.","en":"Addressing confirmed by frame examples: read 30001 L1 voltage 01 04 00 00 00 02 71 CB → 01 04 04 43 66 00 00 0E 1F (230.0) (p.16-17); read 40003 01 03 00 02 00 02 65 CB → 01 03 04 42 70 00 00 EF 90 (60.0); write 15 min 01 10 00 02 00 02 04 41 70 00 00 67 91 → 01 10 00 02 00 02 E0 08 (p.19-20). CRC recomputed and correct for all six."},{"ko":"Float 은 빅 엔디언 — 첫 레지스터가 상위 16비트 (p.15 응답 프레임 설명, 위 예 43 66 00 00 = 230).","en":"Float is big-endian: the first register holds the high 16 bits (p.15 response frame description; example 43 66 00 00 = 230)."},{"ko":"출하값 9600 bps·패리티 없음·국번 1 (p.6 사양표, p.18 40019·40021·40029). 데이터 비트 수는 매뉴얼에 없다.","en":"Defaults 9600 bps, no parity, address 1 (p.6 spec table, p.18 40019/40021/40029). Data bits are not stated."}]},"registers":[{"table":"input-registers","address":0,"manualAddress":"30001","type":"f32","order":"ABCD","name":{"ko":"전압(L-N)","en":"Line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":6,"manualAddress":"30007","type":"f32","order":"ABCD","name":{"ko":"전류","en":"Current"},"unit":"A","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":12,"manualAddress":"30013","type":"f32","order":"ABCD","name":{"ko":"유효전력","en":"Active power"},"unit":"W","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":18,"manualAddress":"30019","type":"f32","order":"ABCD","name":{"ko":"피상전력","en":"Apparent power"},"unit":"VA","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":24,"manualAddress":"30025","type":"f32","order":"ABCD","name":{"ko":"무효전력","en":"Reactive power"},"unit":"VAr","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":30,"manualAddress":"30031","type":"f32","order":"ABCD","name":{"ko":"역률","en":"Power factor"},"access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":70,"manualAddress":"30071","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":72,"manualAddress":"30073","type":"f32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Import active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":74,"manualAddress":"30075","type":"f32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Export active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":76,"manualAddress":"30077","type":"f32","order":"ABCD","name":{"ko":"수전 무효전력량","en":"Import reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":78,"manualAddress":"30079","type":"f32","order":"ABCD","name":{"ko":"송전 무효전력량","en":"Export reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":84,"manualAddress":"30085","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total active power demand"},"unit":"W","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":86,"manualAddress":"30087","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 최대 디맨드","en":"Maximum total active power demand"},"unit":"W","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":88,"manualAddress":"30089","type":"f32","order":"ABCD","name":{"ko":"수전 유효전력 디맨드","en":"Import active power demand"},"unit":"W","access":"r","fc":[4],"description":{"ko":"표 이름은 «Import active energy demand» 이나 단위는 W","en":"Table name says 'Import active energy demand' but unit is W"},"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":90,"manualAddress":"30091","type":"f32","order":"ABCD","name":{"ko":"수전 유효전력 최대 디맨드","en":"Maximum import active power demand"},"unit":"W","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":92,"manualAddress":"30093","type":"f32","order":"ABCD","name":{"ko":"송전 유효전력 디맨드","en":"Export active power demand"},"unit":"W","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":94,"manualAddress":"30095","type":"f32","order":"ABCD","name":{"ko":"송전 유효전력 최대 디맨드","en":"Maximum export active power demand"},"unit":"W","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":258,"manualAddress":"30259","type":"f32","order":"ABCD","name":{"ko":"전류 디맨드","en":"Current demand"},"unit":"A","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":264,"manualAddress":"30265","type":"f32","order":"ABCD","name":{"ko":"전류 최대 디맨드","en":"Maximum current demand"},"unit":"A","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":342,"manualAddress":"30343","type":"f32","order":"ABCD","name":{"ko":"총 유효전력량","en":"Total active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"input-registers","address":344,"manualAddress":"30345","type":"f32","order":"ABCD","name":{"ko":"총 무효전력량","en":"Total reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"p.16 (PDF 19)"},{"table":"holding-registers","address":2,"manualAddress":"40003","type":"f32","order":"ABCD","name":{"ko":"디맨드 주기","en":"Demand period"},"unit":"min","access":"rw","fc":[3,16],"range":{"min":0,"max":60},"description":{"ko":"출하 60. 0 = 실시간(1초마다 갱신)","en":"Default 60; 0 = real time (updated every second)"},"ref":"p.17 (PDF 20)"},{"table":"holding-registers","address":12,"manualAddress":"40013","type":"f32","order":"ABCD","name":{"ko":"펄스 출력 폭","en":"Relay pulse width"},"unit":"ms","access":"rw","fc":[3,16],"values":[{"value":60,"ko":"60 ms(출하)","en":"60 ms (default)"},{"value":100,"ko":"100 ms","en":"100 ms"},{"value":200,"ko":"200 ms","en":"200 ms"}],"ref":"p.17 (PDF 20)"},{"table":"holding-registers","address":18,"manualAddress":"40019","type":"f32","order":"ABCD","name":{"ko":"패리티·정지 비트","en":"Parity and stop bits"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"정지 1비트·패리티 없음(출하)","en":"1 stop bit, no parity (default)"},{"value":1,"ko":"정지 1비트·짝수 패리티","en":"1 stop bit, even parity"},{"value":2,"ko":"정지 1비트·홀수 패리티","en":"1 stop bit, odd parity"},{"value":3,"ko":"정지 2비트·패리티 없음","en":"2 stop bits, no parity"}],"ref":"p.17-18 (PDF 20-21)"},{"table":"holding-registers","address":20,"manualAddress":"40021","type":"f32","order":"ABCD","name":{"ko":"Modbus 국번","en":"Modbus address"},"access":"rw","fc":[3,16],"range":{"min":1,"max":247},"description":{"ko":"출하 1","en":"Default 1"},"ref":"p.18 (PDF 21)"},{"table":"holding-registers","address":28,"manualAddress":"40029","type":"f32","order":"ABCD","name":{"ko":"통신 속도","en":"Baud rate"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps(출하)","en":"9600 bps (default)"},{"value":5,"ko":"1200 bps","en":"1200 bps"}],"ref":"p.18 (PDF 21)"},{"table":"holding-registers","address":50,"manualAddress":"40051","type":"f32","order":"ABCD","name":{"ko":"CT 1차 전류","en":"CT primary current"},"unit":"A","access":"rw","fc":[3,16],"range":{"min":5,"max":9999},"description":{"ko":"출하 5","en":"Default 5"},"ref":"p.18 (PDF 21)"},{"table":"holding-registers","address":60,"manualAddress":"40061","type":"f32","order":"ABCD","name":{"ko":"백라이트 시간","en":"Backlight time"},"unit":"min","access":"rw","fc":[3,16],"range":{"min":0,"max":121},"description":{"ko":"0 = 늘 켬, 121 = 늘 끔, 출하 60","en":"0 = always on, 121 = always off, default 60"},"ref":"p.18 (PDF 21)"},{"table":"holding-registers","address":86,"manualAddress":"40087","type":"f32","order":"ABCD","name":{"ko":"펄스 1 출력 대상","en":"Pulse 1 output mode"},"access":"rw","fc":[3,16],"values":[{"value":1,"ko":"수전 유효전력량","en":"Import active energy"},{"value":2,"ko":"수전 + 송전 유효전력량","en":"Import + export active energy"},{"value":4,"ko":"송전 유효전력량(출하)","en":"Export active energy (default)"},{"value":5,"ko":"수전 무효전력량","en":"Import reactive energy"},{"value":6,"ko":"수전 + 송전 무효전력량","en":"Import + export reactive energy"},{"value":8,"ko":"송전 무효전력량","en":"Export reactive energy"}],"ref":"p.18 (PDF 21)"},{"table":"holding-registers","address":61456,"manualAddress":"461457","type":"u16","name":{"ko":"리셋","en":"Reset"},"access":"w","fc":[16],"values":[{"value":0,"ko":"최대 디맨드 리셋","en":"Reset maximum demand"}],"description":{"ko":"2바이트 Hex(F0 10)","en":"2-byte hex (F0 10)"},"ref":"p.18 (PDF 21)"},{"table":"holding-registers","address":63760,"manualAddress":"463761","type":"u16","name":{"ko":"펄스 1 정수","en":"Pulse 1 rate"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"0.001 kWh/imp(출하)","en":"0.001 kWh/imp (default)"},{"value":1,"ko":"0.01 kWh/imp","en":"0.01 kWh/imp"},{"value":2,"ko":"0.1 kWh/imp","en":"0.1 kWh/imp"},{"value":3,"ko":"1 kWh/imp","en":"1 kWh/imp"}],"description":{"ko":"2바이트 Hex(F9 10)","en":"2-byte hex (F9 10)"},"ref":"p.19 (PDF 22)"}],"notes":[{"ko":"뺀 레지스터: 463779 계량 모드(번호 463779 는 F9 22 인데 Hex 칸은 F9 20 — 어느 쪽이 맞는지 예가 없음, p.19), 463745 화면 자동 넘김 시간(형식 BCD), 464513 일련번호(unsigned int32 — 워드 순서가 매뉴얼에 없음).","en":"Left out: 463779 metering mode (number 463779 means F9 22 but the Hex column says F9 20; no example decides, p.19), 463745 scroll display time (BCD format), 464513 serial number (unsigned int32 — word order not stated)."},{"ko":"Float 계측값·설정은 2개씩(짝수 시작) 읽고 쓴다. 이 매뉴얼은 40 mA CT 형만 다룬다 — 다른 SDM120 형번은 각자의 매뉴얼로 확인.","en":"Read/write Float values as register pairs (even start). This manual covers the 40 mA CT version only; check other SDM120 variants against their own manuals."}],"sources":[{"title":"SDM120CT-40mA User Manual","publisher":"Eastron Electronic Co., Ltd.","edition":{"ko":"2026 V1.0 (판 이력 1.0 = 2026-07-16 첫 판), 파일명 EastronSDM120CT-M40mAUsermanualV10.pdf (eastrongroup.com 다운로드 센터 2026-07-17 게시)","en":"2026 V1.0 (version history 1.0 = 2026-07-16 initial issue); file name EastronSDM120CT-M40mAUsermanualV10.pdf (posted 2026-07-17 on the eastrongroup.com download center)"},"url":"https://www.eastrongroup.com/eastrongroup/2026/07/17/EastronSDM120CT-M40mAUsermanualV10.pdf","pages":{"ko":"인쇄 p.6 통신 사양, p.14-15 프레임 형식, p.16-17 입력 레지스터·예, p.17-20 홀딩 레지스터·예 (PDF 쪽 = 인쇄 쪽 + 3)","en":"printed p.6 comm specs, p.14-15 frame format, p.16-17 input registers and example, p.17-20 holding registers and examples (PDF page = printed + 3)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"eastron/sdm54","manufacturer":{"ko":"이스트론","en":"Eastron"},"model":"SDM54-M/-2T","models":["SDM54-M","SDM54-2T"],"kind":"power-meter","title":{"ko":"이스트론 SDM54-M/-2T 3상 DIN 레일 전력량계","en":"Eastron SDM54-M/-2T three-phase DIN-rail energy meter"},"summary":{"ko":"모든 값이 IEEE 754 Float32(2 레지스터, 상위 워드 먼저). 계측값은 input register(FC04), 설정은 holding register(FC03 읽기·FC16 쓰기, 한 메시지에 한 파라미터). -2T 는 2요금(Tariff) 레지스터가 더 있다.","en":"All values are IEEE 754 Float32 (2 registers, high word first). Measurements are input registers (FC04); settings are holding registers (FC03 read, FC16 write, one parameter per message). The -2T adds two-tariff registers."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"order":"ABCD","addressing":"plc","notes":[{"ko":"문서는 30001·40001 꼴 번호와 «Modbus Protocol Start Address Hex» 칸을 함께 적는다(30001 ↔ 00 00, 40003 ↔ 00 02). 통신 주소 = 번호 − 30001·− 40001, 461457 은 − 400001 (PDF p.3-10). 문서에 인쇄 쪽 번호가 없어 ref 는 PDF 쪽.","en":"The document lists 30001/40001-style numbers with a 'Modbus Protocol Start Address Hex' column (30001 ↔ 00 00, 40003 ↔ 00 02). Wire address = number − 30001 / − 40001; 461457 uses − 400001 (PDF p.3-10). No printed page numbers, so refs are PDF pages."},{"ko":"주소 기준은 3.8-3.9 절 프레임 예로 확인: Volts 1 읽기 01 04 00 00 00 02 71 CB → 01 04 04 43 66 33 34 1B 38(230.2) (PDF p.22-23), Demand Time 읽기 01 03 00 00 00 02 C4 0B → 01 03 04 3F 80 00 00 F7 CF(1.0) (PDF p.23-24), Demand Period 60 쓰기 01 10 00 02 00 02 04 42 70 00 00 67 D5 → 01 10 00 02 00 02 E0 08 (PDF p.24-25). 예외 응답 01 90 01 8D C0, 진단 01 08 00 00 AA 55 5E 94 까지 여덟 프레임 모두 CRC 를 다시 계산해 맞음.","en":"Addressing confirmed by the frame examples in 3.8-3.9: read Volts 1 01 04 00 00 00 02 71 CB → 01 04 04 43 66 33 34 1B 38 (230.2) (PDF p.22-23); read Demand Time 01 03 00 00 00 02 C4 0B → 01 03 04 3F 80 00 00 F7 CF (1.0) (PDF p.23-24); write Demand Period 60 01 10 00 02 00 02 04 42 70 00 00 67 D5 → 01 10 00 02 00 02 E0 08 (PDF p.24-25). With the exception 01 90 01 8D C0 and diagnostic 01 08 00 00 AA 55 5E 94, CRC recomputed and correct for all eight frames."},{"ko":"기본은 상위 레지스터 먼저(PDF p.2, 위 예 43 66 33 34 = 230.2). 문서는 순서를 «Register Order» 홀딩 레지스터로 바꿀 수 있다고 하지만 그 레지스터는 표에 없다.","en":"Default is most significant register first (PDF p.2; example 43 66 33 34 = 230.2). The document says this can be changed via a 'Register Order' holding register, but that register is not in the table."},{"ko":"출하값 9600 bps·정지 1비트·패리티 없음·국번 1 (PDF p.9-10 40019·40021·40029). 국번 변경은 재시작 뒤 적용.","en":"Defaults 9600 bps, 1 stop bit, no parity, address 1 (PDF p.9-10, 40019/40021/40029). Address change takes effect after restart."},{"ko":"한 번에 읽을 수 있는 양이 문서 안에서 다르다 — «50 값(100 레지스터)» 과 «40 파라미터 이하» (PDF p.3). 40 파라미터(80 레지스터) 이하로 읽는 것이 안전하다.","en":"The read limit differs within the document: '50 values (100 registers)' vs '40 parameters or less' (PDF p.3). Staying at 40 parameters (80 registers) or fewer is safe."}]},"registers":[{"table":"input-registers","address":0,"manualAddress":"30001","type":"f32","order":"ABCD","name":{"ko":"L1 상전압","en":"Phase 1 line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":2,"manualAddress":"30003","type":"f32","order":"ABCD","name":{"ko":"L2 상전압","en":"Phase 2 line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":4,"manualAddress":"30005","type":"f32","order":"ABCD","name":{"ko":"L3 상전압","en":"Phase 3 line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":6,"manualAddress":"30007","type":"f32","order":"ABCD","name":{"ko":"L1 전류","en":"Phase 1 current"},"unit":"A","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":8,"manualAddress":"30009","type":"f32","order":"ABCD","name":{"ko":"L2 전류","en":"Phase 2 current"},"unit":"A","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":10,"manualAddress":"30011","type":"f32","order":"ABCD","name":{"ko":"L3 전류","en":"Phase 3 current"},"unit":"A","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":12,"manualAddress":"30013","type":"f32","order":"ABCD","name":{"ko":"L1 유효전력","en":"Phase 1 active power"},"unit":"W","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":14,"manualAddress":"30015","type":"f32","order":"ABCD","name":{"ko":"L2 유효전력","en":"Phase 2 active power"},"unit":"W","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":16,"manualAddress":"30017","type":"f32","order":"ABCD","name":{"ko":"L3 유효전력","en":"Phase 3 active power"},"unit":"W","access":"r","fc":[4],"ref":"PDF p.3"},{"table":"input-registers","address":30,"manualAddress":"30031","type":"f32","order":"ABCD","name":{"ko":"L1 역률","en":"Phase 1 power factor"},"access":"r","fc":[4],"description":{"ko":"부호 = 전류 방향(+ 정방향, − 역방향)","en":"Sign shows current direction (+ forward, − reverse)"},"ref":"PDF p.4"},{"table":"input-registers","address":32,"manualAddress":"30033","type":"f32","order":"ABCD","name":{"ko":"L2 역률","en":"Phase 2 power factor"},"access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":34,"manualAddress":"30035","type":"f32","order":"ABCD","name":{"ko":"L3 역률","en":"Phase 3 power factor"},"access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":42,"manualAddress":"30043","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":48,"manualAddress":"30049","type":"f32","order":"ABCD","name":{"ko":"선전류 합","en":"Sum of line currents"},"unit":"A","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":52,"manualAddress":"30053","type":"f32","order":"ABCD","name":{"ko":"총 유효전력","en":"Total system power"},"unit":"W","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":56,"manualAddress":"30057","type":"f32","order":"ABCD","name":{"ko":"총 피상전력","en":"Total system volt-amps"},"unit":"VA","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":60,"manualAddress":"30061","type":"f32","order":"ABCD","name":{"ko":"총 무효전력","en":"Total system VAr"},"unit":"VAr","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":62,"manualAddress":"30063","type":"f32","order":"ABCD","name":{"ko":"총 역률","en":"Total system power factor"},"access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":70,"manualAddress":"30071","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":72,"manualAddress":"30073","type":"f32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Total import active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":74,"manualAddress":"30075","type":"f32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Total export active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":76,"manualAddress":"30077","type":"f32","order":"ABCD","name":{"ko":"수전 무효전력량","en":"Total import reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":78,"manualAddress":"30079","type":"f32","order":"ABCD","name":{"ko":"송전 무효전력량","en":"Total export reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":84,"manualAddress":"30085","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total system power demand"},"unit":"W","access":"r","fc":[4],"description":{"ko":"수전 − 송전으로 계산","en":"Calculated as import − export"},"ref":"PDF p.4"},{"table":"input-registers","address":200,"manualAddress":"30201","type":"f32","order":"ABCD","name":{"ko":"L1-L2 선간전압","en":"Line 1 to line 2 voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":202,"manualAddress":"30203","type":"f32","order":"ABCD","name":{"ko":"L2-L3 선간전압","en":"Line 2 to line 3 voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":204,"manualAddress":"30205","type":"f32","order":"ABCD","name":{"ko":"L3-L1 선간전압","en":"Line 3 to line 1 voltage"},"unit":"V","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":224,"manualAddress":"30225","type":"f32","order":"ABCD","name":{"ko":"중성선 전류","en":"Neutral current"},"unit":"A","access":"r","fc":[4],"ref":"PDF p.4"},{"table":"input-registers","address":342,"manualAddress":"30343","type":"f32","order":"ABCD","name":{"ko":"총 유효전력량","en":"Total active energy"},"unit":"kWh","access":"r","fc":[4],"description":{"ko":"수전 + 송전","en":"Import + export"},"ref":"PDF p.5"},{"table":"input-registers","address":344,"manualAddress":"30345","type":"f32","order":"ABCD","name":{"ko":"총 무효전력량","en":"Total reactive energy"},"unit":"kVArh","access":"r","fc":[4],"description":{"ko":"수전 + 송전","en":"Import + export"},"ref":"PDF p.5"},{"table":"holding-registers","address":2,"manualAddress":"40003","type":"f32","order":"ABCD","name":{"ko":"디맨드 주기","en":"Demand period"},"unit":"min","access":"rw","fc":[3,16],"values":[{"value":0,"ko":"0(현재값 표시)","en":"0 (shows present value)"},{"value":5,"ko":"5","en":"5"},{"value":8,"ko":"8","en":"8"},{"value":10,"ko":"10","en":"10"},{"value":15,"ko":"15","en":"15"},{"value":20,"ko":"20","en":"20"},{"value":30,"ko":"30","en":"30"},{"value":60,"ko":"60(출하)","en":"60 (default)"}],"ref":"PDF p.8-9"},{"table":"holding-registers","address":10,"manualAddress":"40011","type":"f32","order":"ABCD","name":{"ko":"결선 방식","en":"System type"},"access":"rw","fc":[3,16],"values":[{"value":1,"ko":"1P2W","en":"1P2W"},{"value":3,"ko":"3P4W","en":"3P4W"},{"value":4,"ko":"1P3W","en":"1P3W"}],"description":{"ko":"쓰려면 비밀번호(40025) 먼저","en":"Requires password (40025) first"},"ref":"PDF p.9"},{"table":"holding-registers","address":12,"manualAddress":"40013","type":"f32","order":"ABCD","name":{"ko":"펄스 1 폭","en":"Pulse 1 width"},"unit":"ms","access":"rw","fc":[3,16],"values":[{"value":60,"ko":"60 ms","en":"60 ms"},{"value":100,"ko":"100 ms(출하)","en":"100 ms (default)"},{"value":200,"ko":"200 ms","en":"200 ms"}],"ref":"PDF p.9"},{"table":"holding-registers","address":18,"manualAddress":"40019","type":"f32","order":"ABCD","name":{"ko":"패리티·정지 비트","en":"Network parity and stop bits"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"정지 1비트·패리티 없음(출하)","en":"1 stop bit, no parity (default)"},{"value":1,"ko":"정지 1비트·짝수 패리티","en":"1 stop bit, even parity"},{"value":2,"ko":"정지 1비트·홀수 패리티","en":"1 stop bit, odd parity"},{"value":3,"ko":"정지 2비트·패리티 없음","en":"2 stop bits, no parity"}],"ref":"PDF p.9"},{"table":"holding-registers","address":20,"manualAddress":"40021","type":"f32","order":"ABCD","name":{"ko":"Modbus 국번","en":"Network node address"},"access":"rw","fc":[3,16],"range":{"min":1,"max":247},"description":{"ko":"출하 1, 재시작 뒤 적용","en":"Default 1; effective after restart"},"ref":"PDF p.9"},{"table":"holding-registers","address":22,"manualAddress":"40023","type":"f32","order":"ABCD","name":{"ko":"펄스 1 정수","en":"Pulse 1 divisor"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"400 imp/kWh(kVArh)","en":"400 imp/kWh (kVArh)"},{"value":1,"ko":"100 imp/kWh(kVArh)","en":"100 imp/kWh (kVArh)"},{"value":2,"ko":"10 imp/kWh(kVArh)","en":"10 imp/kWh (kVArh)"},{"value":3,"ko":"1 kWh(kVArh)/imp","en":"1 kWh (kVArh)/imp"},{"value":4,"ko":"0.1 imp/kWh(kVArh)","en":"0.1 imp/kWh (kVArh)"},{"value":5,"ko":"0.01 imp/kWh(kVArh)","en":"0.01 imp/kWh (kVArh)"}],"ref":"PDF p.10"},{"table":"holding-registers","address":24,"manualAddress":"40025","type":"f32","order":"ABCD","name":{"ko":"비밀번호","en":"Password"},"access":"rw","fc":[3,16],"description":{"ko":"보호된 레지스터를 쓰기 전에 쓴다. 출하 1000, 1분 뒤 만료 (PDF p.11)","en":"Write before changing protected registers; default 1000, times out after 1 minute (PDF p.11)"},"ref":"PDF p.10"},{"table":"holding-registers","address":28,"manualAddress":"40029","type":"f32","order":"ABCD","name":{"ko":"통신 속도","en":"Network baud rate"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps(출하)","en":"9600 bps (default)"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"}],"description":{"ko":"재시작 뒤 적용","en":"Effective after restart"},"ref":"PDF p.10"},{"table":"holding-registers","address":86,"manualAddress":"40087","type":"f32","order":"ABCD","name":{"ko":"펄스 1 출력 대상","en":"Pulse 1 energy type"},"access":"rw","fc":[3,16],"values":[{"value":1,"ko":"수전 유효전력량","en":"Import active energy"},{"value":2,"ko":"총 유효전력량","en":"Total active energy"},{"value":4,"ko":"송전 유효전력량(출하)","en":"Export active energy (default)"},{"value":5,"ko":"수전 무효전력량","en":"Import reactive energy"},{"value":6,"ko":"총 무효전력량","en":"Total reactive energy"},{"value":8,"ko":"송전 무효전력량","en":"Export reactive energy"}],"ref":"PDF p.10"},{"table":"holding-registers","address":61456,"manualAddress":"461457","type":"u16","name":{"ko":"리셋","en":"Reset"},"access":"w","fc":[16],"values":[{"value":0,"ko":"최대 디맨드 리셋","en":"Reset maximum demand"}],"description":{"ko":"2바이트 Hex(F0 10)","en":"2-byte hex (F0 10)"},"ref":"PDF p.10-11"}],"notes":[{"ko":"뺀 레지스터: 40015 Password Lock(설명은 «아무 값이나 쓰면 잠금» 인데 Mode 칸은 r), 40059 Scroll time·40061 Backlight time(설명 칸에 Demand period 문장이 섞여 있음), 464513 일련번호(unsigned int32 — 워드 순서 없음), 40001 Demand Time(예에만 나오고 표에 없음), -2T 전용 요금별 레지스터(34877~·35471~, 35487 이 두 번 나옴).","en":"Left out: 40015 Password Lock (text says 'write any value to lock' but Mode is r), 40059 Scroll time and 40061 Backlight time (description cells mixed with demand-period text), 464513 serial number (unsigned int32, word order not given), 40001 Demand Time (only in the example, not in the table), -2T tariff registers (34877~, 35471~; 35487 appears twice)."},{"ko":"문서 안 모순: «Broadcast mode(주소 0) 지원»(PDF p.2) ↔ «브로드캐스트 주소 미지원»(3장). 30255 는 이름이 총 역률인데 단위가 Degrees 라 뺐다.","en":"Contradictions in the document: 'Broadcast mode (address 0) is supported' (PDF p.2) vs 'broadcast address not supported' (section 3). 30255 is named total power factor but its unit is Degrees, so it is left out."},{"ko":"홀수 개·홀수 시작으로 읽거나 쓰면 예외 응답 (PDF p.2-3).","en":"Reading/writing an odd count or odd start address returns an exception (PDF p.2-3)."}],"sources":[{"title":"SDM54-M/-2T Smart Meter Modbus Protocol Implementation V1.1","publisher":"Zhejiang Eastron Electronic Co., Ltd.","edition":{"ko":"2021 V1.1 (머리말 «SDM54-M/-2T MODBUS PROTOCOL 2021 V1.1»), 파일명 eastronsdm54-msdm54-2tprotocol.pdf (eastrongroup.com 다운로드 센터 2025-03-14 게시)","en":"2021 V1.1 (header 'SDM54-M/-2T MODBUS PROTOCOL 2021 V1.1'); file name eastronsdm54-msdm54-2tprotocol.pdf (posted 2025-03-14 on the eastrongroup.com download center)"},"url":"https://www.eastrongroup.com/eastrongroup/2025/03/14/eastronsdm54-msdm54-2tprotocol.pdf","pages":{"ko":"PDF p.2-3 개요, p.3-8 입력 레지스터, p.8-11 홀딩 레지스터, p.22-26 프레임 예 (인쇄 쪽 번호 없음)","en":"PDF pp.2-3 overview, pp.3-8 input registers, pp.8-11 holding registers, pp.22-26 frame examples (no printed page numbers)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"eastron/sdm630-di","manufacturer":{"ko":"이스트론","en":"Eastron"},"model":"SDM630-DI","kind":"power-meter","title":{"ko":"이스트론 SDM630-DI 3상 DIN 레일 전력량계(직결 100 A, 디지털 입력 2점)","en":"Eastron SDM630-DI three-phase DIN-rail energy meter (100 A direct, 2 digital inputs)"},"summary":{"ko":"계측값은 input register(FC04)에 IEEE 754 Float32(상위 워드 먼저), 설정은 holding register(FC03 읽기·FC16 쓰기)에 Float32. 같은 값을 정수(Int32·Int64)로 주는 310021~ 영역도 있다.","en":"Measurements are IEEE 754 Float32 input registers (FC04, high word first); settings are Float32 holding registers (FC03 read, FC16 write). An integer (Int32/Int64) area from 310021 also exists."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[2400,4800,9600,19200,38400,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"order":"ABCD","addressing":"plc","notes":[{"ko":"매뉴얼은 30001·40001 꼴 번호와 «Modbus Protocol Start Address Hex» 칸을 함께 적는다(30001 ↔ 00 00, 40003 ↔ 00 02). 통신 주소 = 번호 − 30001(입력)·− 40001(홀딩), 6자리(310021·461457 등)는 − 300001·− 400001 (p.20-25).","en":"The manual lists 30001/40001-style numbers together with a 'Modbus Protocol Start Address Hex' column (30001 ↔ 00 00, 40003 ↔ 00 02). Wire address = number − 30001 (input) or − 40001 (holding); 6-digit numbers (310021, 461457 …) use − 300001 / − 400001 (p.20-25)."},{"ko":"주소 기준은 p.26-27 프레임 예로 확인: 40003 Demand Period 읽기 01 03 00 02 00 02 65 CB → 01 03 04 42 70 00 00 EF 90(60.0), 15분 쓰기 01 10 00 02 00 02 04 41 70 00 00 67 91 → 01 10 00 02 00 02 E0 08. 네 프레임 모두 CRC 를 다시 계산해 맞음. 입력 레지스터의 숫자 예는 이 매뉴얼에 없어 표의 Hex 칸(30001 ↔ 00 00)으로 맞췄다.","en":"Addressing confirmed by the frame examples on p.26-27: read 40003 Demand Period 01 03 00 02 00 02 65 CB → 01 03 04 42 70 00 00 EF 90 (60.0); write 15 min 01 10 00 02 00 02 04 41 70 00 00 67 91 → 01 10 00 02 00 02 E0 08. CRC recomputed and correct for all four. This manual has no numeric input-register example, so input addresses follow the table's Hex column (30001 ↔ 00 00)."},{"ko":"Float 은 빅 엔디언 — 첫 레지스터가 상위 16비트 (p.19-20 응답 프레임 설명, 위 예 42 70 00 00 = 60.0).","en":"Float is big-endian: the first register holds the high 16 bits (p.19-20 response frame description; example 42 70 00 00 = 60.0)."},{"ko":"출하값 9600 bps·패리티 없음·국번 1 (p.7 2.7.1, p.24 40019·40021). 속도 115.2k 는 40029 값 6 (5 는 표에 없음) (p.25).","en":"Defaults 9600 bps, no parity, address 1 (p.7 2.7.1, p.24 40019/40021). 115.2k is value 6 in 40029 (5 is not listed) (p.25)."}]},"registers":[{"table":"input-registers","address":0,"manualAddress":"30001","type":"f32","order":"ABCD","name":{"ko":"L1 상전압","en":"L1 line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":2,"manualAddress":"30003","type":"f32","order":"ABCD","name":{"ko":"L2 상전압","en":"L2 line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":4,"manualAddress":"30005","type":"f32","order":"ABCD","name":{"ko":"L3 상전압","en":"L3 line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":6,"manualAddress":"30007","type":"f32","order":"ABCD","name":{"ko":"L1 전류","en":"L1 current"},"unit":"A","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":8,"manualAddress":"30009","type":"f32","order":"ABCD","name":{"ko":"L2 전류","en":"L2 current"},"unit":"A","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":10,"manualAddress":"30011","type":"f32","order":"ABCD","name":{"ko":"L3 전류","en":"L3 current"},"unit":"A","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":12,"manualAddress":"30013","type":"f32","order":"ABCD","name":{"ko":"L1 유효전력","en":"L1 active power"},"unit":"W","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":14,"manualAddress":"30015","type":"f32","order":"ABCD","name":{"ko":"L2 유효전력","en":"L2 active power"},"unit":"W","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":16,"manualAddress":"30017","type":"f32","order":"ABCD","name":{"ko":"L3 유효전력","en":"L3 active power"},"unit":"W","access":"r","fc":[4],"ref":"p.20 (PDF 23)"},{"table":"input-registers","address":30,"manualAddress":"30031","type":"f32","order":"ABCD","name":{"ko":"L1 역률","en":"L1 power factor"},"access":"r","fc":[4],"description":{"ko":"부호 = 전류 방향(+ 정방향, − 역방향)","en":"Sign shows current direction (+ forward, − reverse)"},"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":32,"manualAddress":"30033","type":"f32","order":"ABCD","name":{"ko":"L2 역률","en":"L2 power factor"},"access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":34,"manualAddress":"30035","type":"f32","order":"ABCD","name":{"ko":"L3 역률","en":"L3 power factor"},"access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":42,"manualAddress":"30043","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average line-to-neutral voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":46,"manualAddress":"30047","type":"f32","order":"ABCD","name":{"ko":"평균 전류","en":"Average line current"},"unit":"A","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":52,"manualAddress":"30053","type":"f32","order":"ABCD","name":{"ko":"총 유효전력","en":"Total active power"},"unit":"W","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":56,"manualAddress":"30057","type":"f32","order":"ABCD","name":{"ko":"총 피상전력","en":"Total apparent power"},"unit":"VA","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":60,"manualAddress":"30061","type":"f32","order":"ABCD","name":{"ko":"총 무효전력","en":"Total reactive power"},"unit":"VAr","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":62,"manualAddress":"30063","type":"f32","order":"ABCD","name":{"ko":"총 역률","en":"Total power factor"},"access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":70,"manualAddress":"30071","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":72,"manualAddress":"30073","type":"f32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Import active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":74,"manualAddress":"30075","type":"f32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Export active energy"},"unit":"kWh","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":76,"manualAddress":"30077","type":"f32","order":"ABCD","name":{"ko":"수전 무효전력량","en":"Import reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":78,"manualAddress":"30079","type":"f32","order":"ABCD","name":{"ko":"송전 무효전력량","en":"Export reactive energy"},"unit":"kVArh","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":84,"manualAddress":"30085","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total active power demand"},"unit":"W","access":"r","fc":[4],"description":{"ko":"수전 − 송전으로 계산","en":"Calculated as import − export"},"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":200,"manualAddress":"30201","type":"f32","order":"ABCD","name":{"ko":"L1-L2 선간전압","en":"L1-L2 voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":202,"manualAddress":"30203","type":"f32","order":"ABCD","name":{"ko":"L2-L3 선간전압","en":"L2-L3 voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":204,"manualAddress":"30205","type":"f32","order":"ABCD","name":{"ko":"L3-L1 선간전압","en":"L3-L1 voltage"},"unit":"V","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":224,"manualAddress":"30225","type":"f32","order":"ABCD","name":{"ko":"중성선 전류","en":"Neutral current"},"unit":"A","access":"r","fc":[4],"ref":"p.21 (PDF 24)"},{"table":"input-registers","address":342,"manualAddress":"30343","type":"f32","order":"ABCD","name":{"ko":"총 유효전력량","en":"Total active energy"},"unit":"kWh","access":"r","fc":[4],"description":{"ko":"수전 + 송전","en":"Import + export"},"ref":"p.22 (PDF 25)"},{"table":"input-registers","address":344,"manualAddress":"30345","type":"f32","order":"ABCD","name":{"ko":"총 무효전력량","en":"Total reactive energy"},"unit":"kVArh","access":"r","fc":[4],"description":{"ko":"수전 + 송전","en":"Import + export"},"ref":"p.22 (PDF 25)"},{"table":"holding-registers","address":0,"manualAddress":"40001","type":"f32","order":"ABCD","name":{"ko":"디맨드 경과 시간","en":"Demand time"},"unit":"min","access":"r","fc":[3],"description":{"ko":"첫 디맨드 계산까지 지난 분. Demand Period 에 이르면 디맨드 값이 유효","en":"Minutes into the first demand calculation; demand values are valid once it reaches the demand period"},"ref":"p.24 (PDF 27)"},{"table":"holding-registers","address":2,"manualAddress":"40003","type":"f32","order":"ABCD","name":{"ko":"디맨드 주기","en":"Demand period"},"unit":"min","access":"rw","fc":[3,16],"range":{"min":0,"max":60},"description":{"ko":"출하 60. 0 = 실시간(1초마다 갱신)","en":"Default 60; 0 = real time (updated every second)"},"ref":"p.24 (PDF 27)"},{"table":"holding-registers","address":10,"manualAddress":"40011","type":"f32","order":"ABCD","name":{"ko":"결선 방식","en":"System type"},"access":"rw","fc":[3,16],"values":[{"value":1,"ko":"1P2W","en":"1P2W"},{"value":2,"ko":"3P3W","en":"3P3W"},{"value":3,"ko":"3P4W(출하)","en":"3P4W (default)"}],"ref":"p.24 (PDF 27)"},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"f32","order":"ABCD","name":{"ko":"주요 파라미터 설정 권한(KPPA)","en":"Key parameter programming authorization (KPPA)"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"권한 없음","en":"Not authorized"},{"value":1,"ko":"권한 있음","en":"Authorized"}],"description":{"ko":"읽으면 상태, 맞는 비밀번호를 쓰면 주요 파라미터 설정 권한을 얻는다","en":"Read for status; write the correct password to enable programming of key parameters"},"ref":"p.24 (PDF 27)"},{"table":"holding-registers","address":18,"manualAddress":"40019","type":"f32","order":"ABCD","name":{"ko":"패리티·정지 비트","en":"Parity and stop bits"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"정지 1비트·패리티 없음(출하)","en":"1 stop bit, no parity (default)"},{"value":1,"ko":"정지 1비트·짝수 패리티","en":"1 stop bit, even parity"},{"value":2,"ko":"정지 1비트·홀수 패리티","en":"1 stop bit, odd parity"},{"value":3,"ko":"정지 2비트·패리티 없음","en":"2 stop bits, no parity"}],"ref":"p.24 (PDF 27)"},{"table":"holding-registers","address":20,"manualAddress":"40021","type":"f32","order":"ABCD","name":{"ko":"Modbus 국번","en":"Modbus address"},"access":"rw","fc":[3,16],"range":{"min":1,"max":247},"description":{"ko":"출하 1","en":"Default 1"},"ref":"p.24 (PDF 27)"},{"table":"holding-registers","address":24,"manualAddress":"40025","type":"f32","order":"ABCD","name":{"ko":"비밀번호","en":"Password"},"access":"rw","fc":[3,16],"range":{"min":0,"max":9999},"description":{"ko":"출하 1000","en":"Default 1000"},"ref":"p.25 (PDF 28)"},{"table":"holding-registers","address":28,"manualAddress":"40029","type":"f32","order":"ABCD","name":{"ko":"통신 속도","en":"Baud rate"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps(출하)","en":"9600 bps (default)"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"},{"value":6,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.25 (PDF 28)"},{"table":"holding-registers","address":60,"manualAddress":"40061","type":"f32","order":"ABCD","name":{"ko":"백라이트 시간","en":"Backlight time"},"unit":"min","access":"rw","fc":[3,16],"range":{"min":0,"max":121},"description":{"ko":"0 = 늘 켬, 121 = 늘 끔, 출하 60","en":"0 = always on, 121 = always off, default 60"},"ref":"p.25 (PDF 28)"},{"table":"holding-registers","address":61456,"manualAddress":"461457","type":"u16","name":{"ko":"리셋","en":"Reset"},"access":"w","fc":[16],"values":[{"value":0,"ko":"최대 디맨드 리셋","en":"Reset maximum demand"},{"value":6,"ko":"DI 카운트 리셋","en":"Reset DI counts"}],"description":{"ko":"2바이트 Hex(F0 10)","en":"2-byte hex (F0 10)"},"ref":"p.25 (PDF 28)"}],"notes":[{"ko":"정수 영역(310021~ Int64 Wh·VArh, 310251~ Int32 0.1 V 등)은 넣지 않았다 — 매뉴얼은 Float 의 워드 순서만 적고 Int32·Int64 의 워드 순서는 적지 않는다 (p.19-20, p.22-23). 일련번호(464513, unsigned int32)도 같은 이유로 뺐다.","en":"The integer area (310021~ Int64 Wh/VArh, 310251~ Int32 0.1 V etc.) is left out: the manual states word order only for Float, not for Int32/Int64 (p.19-20, p.22-23). Serial number (464513, unsigned int32) is left out for the same reason."},{"ko":"뺀 레지스터: 30255(이름은 총 역률인데 단위가 Degrees, p.21), 40071 CO2 RATE(범위는 소수인데 형식 칸이 hex, p.25), 40769 DI 필터 시간(통신 표는 ms·0~255, 설정 메뉴 p.18 은 000~255 min — 단위가 어긋남), 40770·40772 DI 카운트(홀수 주소의 unsigned int32, 워드 순서 없음).","en":"Left out: 30255 (named total power factor but unit Degrees, p.21), 40071 CO2 RATE (decimal range but format 'hex', p.25), 40769 DI filter time (comm table says ms, 0-255; setup menu p.18 says 000-255 min — units disagree), 40770/40772 DI counts (unsigned int32 at odd addresses, no word order)."},{"ko":"Float 계측값은 2개씩(짝수 시작) 읽는다. 이 매뉴얼은 같은 이스트론 SDM630 계열이라도 SDM630-DI 만 다룬다 — 다른 SDM630 형번은 각자의 매뉴얼로 확인.","en":"Read Float values as register pairs (even start). This manual covers SDM630-DI only; check other SDM630 variants against their own manuals."}],"sources":[{"title":"SDM630-DI User Manual","publisher":"Eastron Electronic Co., Ltd.","edition":{"ko":"2025 V1.01(표지·머리말), 판 이력 표 마지막 줄 1.02 2025-08-04, 파일명 eastronsdm630-diusermanualv1.02.pdf (eastrongroup.com 다운로드 센터 2025-08-06 게시)","en":"2025 V1.01 (cover and headers); version history last row 1.02 dated 2025-08-04; file name eastronsdm630-diusermanualv1.02.pdf (posted 2025-08-06 on the eastrongroup.com download center)"},"url":"https://www.eastrongroup.com/eastrongroup/2025/08/06/eastronsdm630-diusermanualv1.02.pdf","pages":{"ko":"인쇄 p.7 통신 사양, p.19-20 프레임 형식, p.20-23 입력 레지스터, p.23-27 홀딩 레지스터·프레임 예 (PDF 쪽 = 인쇄 쪽 + 3)","en":"printed p.7 comm specs, p.19-20 frame format, p.20-23 input registers, p.23-27 holding registers and frame examples (PDF page = printed + 3)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"fuji-electric/frenic-ace","manufacturer":{"ko":"후지전기","en":"Fuji Electric"},"model":"FRENIC-Ace","kind":"inverter","title":{"ko":"후지전기 FRENIC-Ace 인버터 (RS-485 Modbus RTU)","en":"Fuji Electric FRENIC-Ace inverter (RS-485 Modbus RTU)"},"summary":{"ko":"RS-485 Modbus RTU(RJ45 포트 1·DX± 단자 포트 2). 레지스터 주소 = 기능 코드 그룹 × 256 + 번호(S = 07h, M = 08h): 주파수 지령 S05 (0705h), 운전 명령 S06 (0706h), 출력 주파수 M09 (0809h), 운전 상태 M14 (080Eh)","en":"RS-485 Modbus RTU (RJ45 port 1, DX+/DX- terminal port 2). Register address = function code group × 256 + number (S = 07h, M = 08h): frequency reference S05 (0705h), operation command S06 (0706h), output frequency M09 (0809h), operation status M14 (080Eh)"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":2,"unit":1,"unitRange":[1,247],"addressing":"zero","notes":[{"ko":"주소 체계: 공통 RS-485 매뉴얼(24A7-E-0082)의 CRC 계산 예(p.3-21~3-22)는 국번 1, FC03, 기능 코드 P02(그룹 03h, 번호 02h), 20개 읽기를 01 03 03 02 00 14 E4 41 로 보낸다. 레지스터 주소 = 그룹 코드 × 256 + 번호(0 기준). CRC 도 계산값과 맞다. 후지 응용 노트 FECA-AN-183(p.4)도 FRENIC-Ace 의 S05 를 0705h(1797)로 적는다.","en":"Addressing: the CRC example in the common RS-485 manual (24A7-E-0082, pp.3-21-3-22) reads 20 words from function code P02 (group 03h, number 02h) at station 1 with 01 03 03 02 00 14 E4 41. Register address = group code × 256 + number (0-based). The CRC matches calculation. Fuji application note FECA-AN-183 (p.4) also gives FRENIC-Ace S05 as 0705h (1797)."},{"ko":"출하값(FECA-AN-183 p.3): 국번 y01/y11 = 1, 속도 y04/y14 = 3(19200 bps), 데이터 y05/y15 = 0(8비트), 패리티 y06/y16 = 0(없음, 정지 2비트), 프로토콜 y10 = 1(FRENIC Loader)·y20 = 0(Modbus RTU). 곧 DX± 단자(포트 2)는 출하 상태로 Modbus RTU, RJ45(포트 1)는 y10 = 0 으로 바꿔야 한다.","en":"Factory settings (FECA-AN-183 p.3): station y01/y11 = 1, baud y04/y14 = 3 (19200 bps), data y05/y15 = 0 (8 bits), parity y06/y16 = 0 (none, 2 stop bits), protocol y10 = 1 (FRENIC Loader) and y20 = 0 (Modbus RTU). So the DX+/DX- terminals (port 2) speak Modbus RTU out of the box; the RJ45 jack (port 1) needs y10 = 0."},{"ko":"함수 코드 01(80코일)·03(100레지스터)·05·06·08·15(16코일)·16(100레지스터) (FECA-AN-183 p.4). 패리티 1 짝수·2 홀수·3 없음(정지 1비트)도 고를 수 있다.","en":"Function codes 01 (80 coils), 03 (100 registers), 05, 06, 08, 15 (16 coils) and 16 (100 registers) (FECA-AN-183 p.4). Parity 1 even, 2 odd and 3 none (1 stop bit) are also selectable."}]},"registers":[{"table":"holding-registers","address":1793,"manualAddress":"S01 (0701h)","type":"s16","name":{"ko":"S01 주파수 지령 (p.u.)","en":"S01 Frequency reference (p.u.)"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = 최대 주파수. S01 이 0 이 아니면 S05 보다 앞선다","en":"±20000 = maximum frequency. When S01 is not 0 it takes precedence over S05"},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1797,"manualAddress":"S05 (0705h)","type":"u16","name":{"ko":"S05 주파수 지령","en":"S05 Frequency reference"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":655.35},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1798,"manualAddress":"S06 (0706h)","type":"u16","name":{"ko":"S06 운전 명령","en":"S06 Operation command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력","en":"X4 general-purpose input"},{"bit":6,"ko":"X5 범용 입력","en":"X5 general-purpose input"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"description":{"ko":"형식 [14]. 매뉴얼 예: FWD·X1 켬 = 0005h. 비트 15 로 경보를 리셋하려면 1 로 쓴 뒤 다시 0 으로 쓴다","en":"Format [14]. Manual example: FWD and X1 on = 0005h. To reset an alarm with bit 15, write 1 and then 0 again"},"ref":"p.5-31 표 5.31, p.5-45","source":1},{"table":"holding-registers","address":1799,"manualAddress":"S07 (0707h)","type":"u16","name":{"ko":"S07 범용 DO","en":"S07 Universal DO"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"}],"description":{"ko":"형식 [15] — 범용 DO 로 정한 출력 단자를 통신으로 켠다","en":"Format [15]: drives output terminals assigned to universal DO"},"ref":"p.5-31 표 5.31, p.5-45","source":1},{"table":"holding-registers","address":1800,"manualAddress":"S08 (0708h)","type":"u16","name":{"ko":"S08 가속 시간 (F07)","en":"S08 Acceleration time (F07)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"형식 [3](0.1 단위)","en":"Format [3] (0.1 units)"},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1801,"manualAddress":"S09 (0709h)","type":"u16","name":{"ko":"S09 감속 시간 (F08)","en":"S09 Deceleration time (F08)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"형식 [3](0.1 단위)","en":"Format [3] (0.1 units)"},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1804,"manualAddress":"S12 (070Ch)","type":"s16","name":{"ko":"S12 범용 AO","en":"S12 Universal AO"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = 풀 스케일","en":"±20000 = full scale"},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1805,"manualAddress":"S13 (070Dh)","type":"s16","name":{"ko":"S13 PID 지령","en":"S13 PID command"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1806,"manualAddress":"S14 (070Eh)","type":"u16","name":{"ko":"S14 경보 리셋 명령","en":"S14 Alarm reset command"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"경보 리셋","en":"Alarm reset"}],"description":{"ko":"1 을 쓰면 리셋한다. 읽으면 늘 0","en":"Writing 1 resets the alarm. Always reads 0"},"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":1811,"manualAddress":"S19 (0713h)","type":"s16","name":{"ko":"S19 속도 지령","en":"S19 Speed command"},"unit":"r/min","access":"rw","fc":[3,6,16],"ref":"p.5-31 표 5.31","source":1},{"table":"holding-registers","address":2049,"manualAddress":"M01 (0801h)","type":"s16","name":{"ko":"M01 주파수 지령 (p.u.) (최종 지령)","en":"M01 Frequency reference (p.u.) (final command)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2050,"manualAddress":"M02 (0802h)","type":"s16","name":{"ko":"M02 토크 지령 (최종 지령)","en":"M02 Torque command (final command)"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 토크 = 100%","en":"100% = motor rated torque"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2051,"manualAddress":"M03 (0803h)","type":"s16","name":{"ko":"M03 토크 전류 지령 (최종 지령)","en":"M03 Torque current command (final command)"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 토크 전류 = 100%","en":"100% = motor rated torque current"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2052,"manualAddress":"M04 (0804h)","type":"s16","name":{"ko":"M04 자속 지령","en":"M04 Flux command"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 자속 = 100%","en":"100% = rated motor flux"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2053,"manualAddress":"M05 (0805h)","type":"u16","name":{"ko":"M05 주파수 지령 (최종 지령)","en":"M05 Frequency reference (final command)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2054,"manualAddress":"M06 (0806h)","type":"s16","name":{"ko":"M06 출력 주파수 1 (p.u.)","en":"M06 Output frequency 1 (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수, 슬립 보상 전","en":"±20000 = maximum frequency, before slip compensation"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2055,"manualAddress":"M07 (0807h)","type":"s16","name":{"ko":"M07 토크 실제값","en":"M07 Torque real value"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 토크 = 100%","en":"100% = motor rated torque"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2056,"manualAddress":"M08 (0808h)","type":"s16","name":{"ko":"M08 토크 전류","en":"M08 Torque current"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 토크 전류 = 100%","en":"100% = motor rated torque current"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2057,"manualAddress":"M09 (0809h)","type":"u16","name":{"ko":"M09 출력 주파수","en":"M09 Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Modbus RTU 는 형식 [22](0.00~655.35 Hz, 부호 없음)","en":"Modbus RTU uses format [22] (0.00-655.35 Hz, unsigned)"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2058,"manualAddress":"M10 (080Ah)","type":"u16","name":{"ko":"M10 입력 전력","en":"M10 Input power"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"«적용 모터 공칭 출력» = 100%","en":"100% = nominal applicable motor output"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2059,"manualAddress":"M11 (080Bh)","type":"u16","name":{"ko":"M11 출력 전류 실효값","en":"M11 Output current effective value"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"인버터 정격 전류 = 100%","en":"100% = inverter rated current"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2060,"manualAddress":"M12 (080Ch)","type":"u16","name":{"ko":"M12 출력 전압 실효값","en":"M12 Output voltage effective value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"형식 [3](0.1 단위)이지만 소수점 아래 값은 없다(1.0 V 단위로 바뀜)","en":"Format [3] (0.1 units) but there is no fractional part (changes in 1.0 V steps)"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2061,"manualAddress":"M13 (080Dh)","type":"u16","name":{"ko":"M13 운전 명령 (최종 지령)","en":"M13 Operation command (final command)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력","en":"X4 general-purpose input"},{"bit":6,"ko":"X5 범용 입력","en":"X5 general-purpose input"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"description":{"ko":"형식 [14] — 키패드·단자·통신을 합친 최종 명령","en":"Format [14]: final command from keypad, terminals and communications"},"ref":"p.5-32 표 5.32, p.5-45","source":1},{"table":"holding-registers","address":2062,"manualAddress":"M14 (080Eh)","type":"u16","name":{"ko":"M14 운전 상태","en":"M14 Operation status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD running forward"},{"bit":1,"ko":"REV 역회전 중","en":"REV running in reverse"},{"bit":2,"ko":"EXT 직류 제동 중(또는 예비 여자 중)","en":"EXT DC braking (or pre-exciting)"},{"bit":3,"ko":"INT 인버터 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중","en":"BRK braking"},{"bit":5,"ko":"NUV 직류 중간 회로 전압 확립(0 = 부족 전압)","en":"NUV DC link voltage established (0 = undervoltage)"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 경보 릴레이(모든 고장)","en":"ALM alarm relay (any fault)"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 기능 코드 데이터 쓰는 중","en":"BUSY writing function code data"}],"description":{"ko":"형식 [16]","en":"Format [16]"},"ref":"p.5-32 표 5.32, p.5-45","source":1},{"table":"holding-registers","address":2063,"manualAddress":"M15 (080Fh)","type":"u16","name":{"ko":"M15 범용 출력 단자 정보","en":"M15 General-purpose output terminal information"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"}],"description":{"ko":"형식 [15]","en":"Format [15]"},"ref":"p.5-32 표 5.32, p.5-45","source":1},{"table":"holding-registers","address":2064,"manualAddress":"M16 (0810h)","type":"u16","name":{"ko":"M16 최근 경보 내용","en":"M16 Latest alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-42)","en":"Alarm code (format [10], p.5-42)"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2065,"manualAddress":"M17 (0811h)","type":"u16","name":{"ko":"M17 직전 경보 내용","en":"M17 Last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-42)","en":"Alarm code (format [10], p.5-42)"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2066,"manualAddress":"M18 (0812h)","type":"u16","name":{"ko":"M18 2회 전 경보 내용","en":"M18 Second last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-42)","en":"Alarm code (format [10], p.5-42)"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2067,"manualAddress":"M19 (0813h)","type":"u16","name":{"ko":"M19 3회 전 경보 내용","en":"M19 Third last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-42)","en":"Alarm code (format [10], p.5-42)"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2068,"manualAddress":"M20 (0814h)","type":"u16","name":{"ko":"M20 누적 운전 시간","en":"M20 Cumulative operation time"},"unit":"h","access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2069,"manualAddress":"M21 (0815h)","type":"u16","name":{"ko":"M21 직류 중간 회로 전압","en":"M21 DC link circuit voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2071,"manualAddress":"M23 (0817h)","type":"u16","name":{"ko":"M23 모델 코드","en":"M23 Model code"},"access":"r","fc":[3],"description":{"ko":"시리즈·세대·모델·전압 계열을 16진 4자리로(형식 [17])","en":"Series, generation, model and voltage series as four hex digits (format [17])"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2072,"manualAddress":"M24 (0818h)","type":"u16","name":{"ko":"M24 용량 코드","en":"M24 Capacity code"},"access":"r","fc":[3],"description":{"ko":"형식 [11]","en":"Format [11]"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2073,"manualAddress":"M25 (0819h)","type":"u16","name":{"ko":"M25 ROM 버전","en":"M25 ROM version"},"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2074,"manualAddress":"M26 (081Ah)","type":"u16","name":{"ko":"M26 전송 오류 처리 코드","en":"M26 Transmission error transaction code"},"access":"r","fc":[3],"description":{"ko":"RS-485 통신 오류 코드(형식 [20])","en":"RS-485 communications error code (format [20])"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2075,"manualAddress":"M27 (081Bh)","type":"s16","name":{"ko":"M27 경보 때 주파수 지령 (p.u.)","en":"M27 Frequency reference on alarm (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2079,"manualAddress":"M31 (081Fh)","type":"u16","name":{"ko":"M31 경보 때 주파수 지령","en":"M31 Frequency reference on alarm"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2080,"manualAddress":"M32 (0820h)","type":"s16","name":{"ko":"M32 경보 때 출력 주파수 1 (p.u.)","en":"M32 Output frequency 1 on alarm (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2081,"manualAddress":"M33 (0821h)","type":"s16","name":{"ko":"M33 경보 때 토크 실제값","en":"M33 Torque real value on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2083,"manualAddress":"M35 (0823h)","type":"u16","name":{"ko":"M35 경보 때 출력 주파수","en":"M35 Output frequency on alarm"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2084,"manualAddress":"M36 (0824h)","type":"u16","name":{"ko":"M36 경보 때 입력 전력","en":"M36 Input power on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2085,"manualAddress":"M37 (0825h)","type":"u16","name":{"ko":"M37 경보 때 출력 전류 실효값","en":"M37 Output current effective value on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2087,"manualAddress":"M39 (0827h)","type":"u16","name":{"ko":"M39 경보 때 운전 명령","en":"M39 Operation command on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력","en":"X4 general-purpose input"},{"bit":6,"ko":"X5 범용 입력","en":"X5 general-purpose input"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"ref":"p.5-32 표 5.32, p.5-45","source":1},{"table":"holding-registers","address":2088,"manualAddress":"M40 (0828h)","type":"u16","name":{"ko":"M40 경보 때 운전 상태","en":"M40 Operation status on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD running forward"},{"bit":1,"ko":"REV 역회전 중","en":"REV running in reverse"},{"bit":2,"ko":"EXT 직류 제동 중(또는 예비 여자 중)","en":"EXT DC braking (or pre-exciting)"},{"bit":3,"ko":"INT 인버터 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중","en":"BRK braking"},{"bit":5,"ko":"NUV 직류 중간 회로 전압 확립(0 = 부족 전압)","en":"NUV DC link voltage established (0 = undervoltage)"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 경보 릴레이(모든 고장)","en":"ALM alarm relay (any fault)"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 기능 코드 데이터 쓰는 중","en":"BUSY writing function code data"}],"ref":"p.5-32 표 5.32, p.5-45","source":1},{"table":"holding-registers","address":2089,"manualAddress":"M41 (0829h)","type":"u16","name":{"ko":"M41 경보 때 출력 단자 정보","en":"M41 Output terminal information on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"}],"ref":"p.5-32 표 5.32, p.5-45","source":1},{"table":"holding-registers","address":2090,"manualAddress":"M42 (082Ah)","type":"u16","name":{"ko":"M42 경보 때 누적 운전 시간","en":"M42 Cumulative operation time on alarm"},"unit":"h","access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2091,"manualAddress":"M43 (082Bh)","type":"u16","name":{"ko":"M43 경보 때 직류 중간 회로 전압","en":"M43 DC link circuit voltage on alarm"},"unit":"V","access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2092,"manualAddress":"M44 (082Ch)","type":"u16","name":{"ko":"M44 경보 때 인버터 내부 공기 온도","en":"M44 Inverter internal air temperature on alarm"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2093,"manualAddress":"M45 (082Dh)","type":"u16","name":{"ko":"M45 경보 때 방열판 온도","en":"M45 Heat sink temperature on alarm"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-32 표 5.32","source":1},{"table":"holding-registers","address":2094,"manualAddress":"M46 (082Eh)","type":"u16","name":{"ko":"M46 주회로 콘덴서 수명","en":"M46 Life of main circuit capacitor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"출하 때 용량 = 100%","en":"100% = capacity at shipment"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2097,"manualAddress":"M49 (0831h)","type":"s16","name":{"ko":"M49 입력 단자 [12] 전압 (p.u.)","en":"M49 Input terminal [12] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2098,"manualAddress":"M50 (0832h)","type":"u16","name":{"ko":"M50 입력 단자 [C1] 전류 (p.u.)","en":"M50 Input terminal [C1] current (p.u.)"},"access":"r","fc":[3],"description":{"ko":"0 = 0 mA, 20000 = 20 mA","en":"0 = 0 mA, 20000 = 20 mA"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2100,"manualAddress":"M52 (0834h)","type":"s16","name":{"ko":"M52 입력 단자 [32] 전압 (p.u.)","en":"M52 Input terminal [32] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2102,"manualAddress":"M54 (0836h)","type":"s16","name":{"ko":"M54 입력 단자 [V2] 전압 (p.u.)","en":"M54 Input terminal [V2] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2109,"manualAddress":"M61 (083Dh)","type":"u16","name":{"ko":"M61 인버터 내부 공기 온도","en":"M61 Inverter internal air temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2110,"manualAddress":"M62 (083Eh)","type":"u16","name":{"ko":"M62 방열판 온도","en":"M62 Heat sink temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2111,"manualAddress":"M63 (083Fh)","type":"s16","name":{"ko":"M63 부하율","en":"M63 Load factor"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 = 100%","en":"100% = motor rating"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2112,"manualAddress":"M64 (0840h)","type":"s16","name":{"ko":"M64 모터 출력","en":"M64 Motor output"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 출력(kW) = 100%","en":"100% = motor rated output (kW)"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2116,"manualAddress":"M68 (0844h)","type":"s16","name":{"ko":"M68 PID 최종 지령","en":"M68 PID final command"},"access":"r","fc":[3],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2120,"manualAddress":"M72 (0848h)","type":"s16","name":{"ko":"M72 PID 피드백 값","en":"M72 PID feedback value"},"access":"r","fc":[3],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-33 표 5.32","source":1},{"table":"holding-registers","address":2121,"manualAddress":"M73 (0849h)","type":"s16","name":{"ko":"M73 PID 출력","en":"M73 PID output"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수(F03)의 ±100%","en":"±20000 = ±100% of maximum frequency (F03)"},"ref":"p.5-33 표 5.32","source":1}],"notes":[{"ko":"형식 번호와 Ace 지원 여부는 보충 문서 24A7-E-0099 의 표 5.31·5.32(Ace 칸 Y)에서, 각 코드의 뜻·기준(p.u.·%의 100%)은 공통 매뉴얼 24A7-E-0082 의 5.1 절에서 확인했다. 형식이 Ace 전용 [74](M47·M48 수명)·[19](M69 정격 전류)이거나 0082 에 뜻이 없는 코드(M78·M79 등)는 뺐다. M53 은 0099 이름(입력 단자 [C2] 전압)과 0082 이름(전류)이 달라 뺐다. M38 은 최소 단위 1.0 과 형식 [3](0.1)이 달라 뺐다.","en":"Format numbers and Ace support come from Tables 5.31 and 5.32 (Ace column Y) of supplement 24A7-E-0099; the meaning and base (100% for p.u. and %) of each code come from section 5.1 of the common manual 24A7-E-0082. Codes using Ace-only formats [74] (M47/M48 life) or [19] (M69 rated current), and codes not described in 0082 (M78, M79 and so on), are left out. M53 is left out because 0099 names it input terminal [C2] voltage while 0082 says current. M38 is left out because its step 1.0 differs from its format [3] (0.1)."},{"ko":"S06 의 X6~X9 비트(7~10)는 Ace 의 입력 단자 수가 이 문서들에 없어 넣지 않았다. 형식 [16] 비트 6 은 비트 그림에서 0(안 씀)인데 표에는 TL(토크 제한 중)로 나와 넣지 않았다 (0099 p.5-45).","en":"S06 bits 7-10 (X6-X9) are left out because these documents do not give the number of Ace input terminals. Bit 6 of format [16] is 0 (unused) in the bit diagram but TL (torque limiting) in the table, so it is left out (0099 p.5-45)."},{"ko":"통신으로 운전·주파수 지령을 주려면 H30 을 통신 쪽으로 정한다(1~8 — 포트 1·2 조합, FECA-AN-183 p.2). 읽기만 할 때는 출하값 0 그대로 된다.","en":"To run the drive and give the frequency reference over communications, set H30 to a communications setting (1-8, port 1/2 combinations, FECA-AN-183 p.2). Reading only works with the factory setting 0."}],"sources":[{"title":"RS-485 User's Manual (FRENIC-Mini, FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA)","publisher":"Fuji Electric","edition":{"ko":"24A7-E-0082 (MEH448) 5판 2009-07, 2014-06 인쇄","en":"24A7-E-0082 (MEH448) 5th edition July 2009, printed 2014-06"},"url":"https://americas.fujielectric.com/files/RS-485_Users_Manual_24A7-E-0082.pdf","pages":{"ko":"Modbus RTU 메시지 p.3-4~3-5, CRC 예 p.3-21~3-22, 명령·모니터 데이터 뜻 p.5-2~5-14","en":"Modbus RTU messages pp.3-4-3-5, CRC example pp.3-21-3-22, meaning of command and monitor data pp.5-2-5-14"},"checked":"2026-10-24"},{"title":"Supplement to RS-485 User's Manual (FRENIC-MEGA, FRENIC-Eco, FRENIC-Multi, FRENIC-Ace, FRENIC-Mini (C2)) Chapter 5.2 Data Formats","publisher":"Fuji Electric","edition":{"ko":"24A7-E-0099, 2014-12","en":"24A7-E-0099, 2014-12"},"url":"https://americas.fujielectric.com/files/24A7-E-0099.pdf","pages":{"ko":"S 코드 형식 번호 p.5-31, M 코드 형식 번호 p.5-32~5-33, 형식 [1]~[6] p.5-41, [10] p.5-42, [14]~[16] p.5-45, [22] p.5-47","en":"S code format numbers p.5-31, M code format numbers pp.5-32-5-33, formats [1]-[6] p.5-41, [10] p.5-42, [14]-[16] p.5-45, [22] p.5-47"},"checked":"2026-10-24"},{"title":"Application Note FECA-AN-183 FRENIC-Ace Modbus Communications","publisher":"Fuji Electric Corp. of America","edition":{"ko":"FECA-AN-183, 2021-02-09","en":"FECA-AN-183, 2021-02-09"},"url":"https://americas.fujielectric.com/wp-content/uploads/2021/03/FRENIC-Ace-Modbus-Communications-FECA-AN-183.pdf","pages":{"ko":"H30 p.2, y 코드 출하값 p.3, Modbus 함수·레지스터 주소 p.4","en":"H30 p.2, y code factory settings p.3, Modbus functions and register addresses p.4"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"fuji-electric/frenic-hvac","manufacturer":{"ko":"후지전기","en":"Fuji Electric"},"model":"FRENIC-HVAC/AQUA","models":["FRENIC-HVAC","FRENIC-AQUA"],"kind":"inverter","title":{"ko":"후지전기 FRENIC-HVAC·AQUA 인버터 (RS-485 Modbus RTU)","en":"Fuji Electric FRENIC-HVAC and AQUA inverters (RS-485 Modbus RTU)"},"summary":{"ko":"RS-485 Modbus RTU(RJ45 포트 1·단자 포트 2). 레지스터 주소 = 기능 코드 그룹 × 256 + 번호(S = 07h, M = 08h): 주파수 지령 S05 (0705h), 운전 명령 S06 (0706h), 출력 주파수 M09 (0809h), 운전 상태 M14 (080Eh)","en":"RS-485 Modbus RTU (RJ45 port 1, terminal port 2). Register address = function code group × 256 + number (S = 07h, M = 08h): frequency reference S05 (0705h), operation command S06 (0706h), output frequency M09 (0809h), operation status M14 (080Eh)"},"protocols":["rtu"],"comm":{"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"unitRange":[1,247],"maxRegisters":50,"addressing":"zero","notes":[{"ko":"주소 체계: 매뉴얼 CRC 계산 예(p.3-22~3-23)는 국번 1, FC03, 기능 코드 P02(그룹 P = 03h, 번호 02h), 20개 읽기를 01 03 03 02 00 14 E4 41 로 보낸다. 통신 주소 = 그룹 코드 × 256 + 번호(0 기준, 표 3.2 p.3-5). CRC 도 계산값과 맞다. 매뉴얼은 «40000 + 그룹 × 256 + 번호»(J60 = 43388) 라고도 적는데, 40001 이 첫 주소인 흔한 PLC 표기와 달리 40000 을 뺀 값이 곧 통신 주소다 (p.3-4).","en":"Addressing: the manual's CRC example (pp.3-22-3-23) reads 20 words from function code P02 (group P = 03h, number 02h) at station 1 with 01 03 03 02 00 14 E4 41. Wire address = group code × 256 + number (0-based, Table 3.2 p.3-5). The CRC matches calculation. The manual also writes «40000 + group × 256 + number» (J60 = 43388); unlike the usual PLC notation where 40001 is the first address, the value minus 40000 is the wire address (p.3-4)."},{"ko":"y04 속도 2400·4800·9600·19200·38400 bps, y06 패리티 0 없음(정지 2비트)·1 짝수·2 홀수·3 없음(정지 1비트), Modbus RTU 는 8비트 고정 (p.2-21). Modbus RTU 로 쓰려면 y10(포트 1)·y20(포트 2) = 0 (p.2-22). 출하값은 이 매뉴얼에 없어 비웠다.","en":"y04 baud 2400/4800/9600/19200/38400 bps; y06 parity 0 none (2 stop bits), 1 even, 2 odd, 3 none (1 stop bit); Modbus RTU is fixed at 8 bits (p.2-21). Set y10 (port 1) or y20 (port 2) = 0 for Modbus RTU (p.2-22). Factory settings are not in this manual and are left empty."},{"ko":"FC03 은 한 번에 50워드까지. 안 쓰는 기능 코드는 오류 없이 0 으로 읽히고, 한 번의 읽기가 그룹을 넘지 않는다 (p.3-5).","en":"FC03 reads up to 50 words at a time. Unused function codes read as 0 without an error, and one read does not cross a group (p.3-5)."}]},"registers":[{"table":"holding-registers","address":1793,"manualAddress":"S01 (0701h)","type":"s16","name":{"ko":"S01 주파수 지령 (p.u.)","en":"S01 Frequency reference (p.u.)"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = 최대 주파수. S01 이 0 이 아니면 S05 보다 앞선다","en":"±20000 = maximum frequency. When S01 is not 0 it takes precedence over S05"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1797,"manualAddress":"S05 (0705h)","type":"u16","name":{"ko":"S05 주파수 지령","en":"S05 Frequency reference"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":655.35},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1798,"manualAddress":"S06 (0706h)","type":"u16","name":{"ko":"S06 운전 명령","en":"S06 Operation command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력","en":"X4 general-purpose input"},{"bit":6,"ko":"X5 범용 입력","en":"X5 general-purpose input"},{"bit":7,"ko":"X6 범용 입력","en":"X6 general-purpose input"},{"bit":8,"ko":"X7 범용 입력","en":"X7 general-purpose input"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"description":{"ko":"형식 [14]. 매뉴얼 예: FWD·X1 켬 = 0005h. 비트 15 로 경보를 리셋하려면 1 로 쓴 뒤 다시 0 으로 쓴다","en":"Format [14]. Manual example: FWD and X1 on = 0005h. To reset an alarm with bit 15, write 1 and then 0 again"},"ref":"p.5-2 표 5.2, p.5-67","source":0},{"table":"holding-registers","address":1799,"manualAddress":"S07 (0707h)","type":"u16","name":{"ko":"S07 범용 DO","en":"S07 Universal DO"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"}],"description":{"ko":"형식 [15] — 범용 DO 로 정한 출력 단자를 통신으로 켠다","en":"Format [15]: drives output terminals assigned to universal DO"},"ref":"p.5-2 표 5.2, p.5-67","source":0},{"table":"holding-registers","address":1800,"manualAddress":"S08 (0708h)","type":"u16","name":{"ko":"S08 가속 시간 (F07)","en":"S08 Acceleration time (F07)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"ref":"p.5-2 표 5.2","source":0,"range":{"min":0,"max":3600}},{"table":"holding-registers","address":1801,"manualAddress":"S09 (0709h)","type":"u16","name":{"ko":"S09 감속 시간 (F08)","en":"S09 Deceleration time (F08)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"ref":"p.5-2 표 5.2","source":0,"range":{"min":0,"max":3600}},{"table":"holding-registers","address":1804,"manualAddress":"S12 (070Ch)","type":"s16","name":{"ko":"S12 범용 AO","en":"S12 Universal AO"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = 풀 스케일","en":"±20000 = full scale"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1805,"manualAddress":"S13 (070Dh)","type":"s16","name":{"ko":"S13 PID 지령","en":"S13 PID command"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1806,"manualAddress":"S14 (070Eh)","type":"u16","name":{"ko":"S14 경보 리셋 명령","en":"S14 Alarm reset command"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"경보 리셋","en":"Alarm reset"}],"description":{"ko":"1 을 쓰면 리셋한다. 읽으면 늘 0","en":"Writing 1 resets the alarm. Always reads 0"},"ref":"p.5-2 표 5.2, p.5-5","source":0},{"table":"holding-registers","address":1811,"manualAddress":"S19 (0713h)","type":"s16","name":{"ko":"S19 속도 지령","en":"S19 Speed command"},"unit":"r/min","access":"rw","fc":[3,6,16],"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":2049,"manualAddress":"M01 (0801h)","type":"s16","name":{"ko":"M01 주파수 지령 (p.u.) (최종 지령)","en":"M01 Frequency reference (p.u.) (final command)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2053,"manualAddress":"M05 (0805h)","type":"u16","name":{"ko":"M05 주파수 지령 (최종 지령)","en":"M05 Frequency reference (final command)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2054,"manualAddress":"M06 (0806h)","type":"s16","name":{"ko":"M06 출력 주파수 1 (p.u.)","en":"M06 Output frequency 1 (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수, 슬립 보상 전","en":"±20000 = maximum frequency, before slip compensation"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2055,"manualAddress":"M07 (0807h)","type":"s16","name":{"ko":"M07 토크 실제값","en":"M07 Torque real value"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 토크 = 100%","en":"100% = motor rated torque"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2057,"manualAddress":"M09 (0809h)","type":"u16","name":{"ko":"M09 출력 주파수","en":"M09 Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Modbus RTU 는 형식 [22](0.00~655.35 Hz, 부호 없음)","en":"Modbus RTU uses format [22] (0.00-655.35 Hz, unsigned)"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2058,"manualAddress":"M10 (080Ah)","type":"u16","name":{"ko":"M10 입력 전력","en":"M10 Input power"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"«적용 모터 공칭 출력» = 100%","en":"100% = nominal applicable motor output"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2059,"manualAddress":"M11 (080Bh)","type":"u16","name":{"ko":"M11 출력 전류 실효값","en":"M11 Output current effective value"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"인버터 정격 전류 = 100%","en":"100% = inverter rated current"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2060,"manualAddress":"M12 (080Ch)","type":"u16","name":{"ko":"M12 출력 전압 실효값","en":"M12 Output voltage effective value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"형식 [3](0.1 단위)이지만 소수점 아래 값은 없다(1.0 V 단위로 바뀜)","en":"Format [3] (0.1 units) but there is no fractional part (changes in 1.0 V steps)"},"ref":"p.5-11 표 5.8","source":0},{"table":"holding-registers","address":2061,"manualAddress":"M13 (080Dh)","type":"u16","name":{"ko":"M13 운전 명령 (최종 지령)","en":"M13 Operation command (final command)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력","en":"X4 general-purpose input"},{"bit":6,"ko":"X5 범용 입력","en":"X5 general-purpose input"},{"bit":7,"ko":"X6 범용 입력","en":"X6 general-purpose input"},{"bit":8,"ko":"X7 범용 입력","en":"X7 general-purpose input"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"description":{"ko":"형식 [14] — 키패드·단자·통신을 합친 최종 명령","en":"Format [14]: final command from keypad, terminals and communications"},"ref":"p.5-12 표 5.9, p.5-67","source":0},{"table":"holding-registers","address":2062,"manualAddress":"M14 (080Eh)","type":"u16","name":{"ko":"M14 운전 상태","en":"M14 Operation status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD running forward"},{"bit":1,"ko":"REV 역회전 중","en":"REV running in reverse"},{"bit":2,"ko":"EXT 직류 제동 중(또는 예비 여자 중)","en":"EXT DC braking (or pre-exciting)"},{"bit":3,"ko":"INT 인버터 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중","en":"BRK braking"},{"bit":5,"ko":"NUV 직류 중간 회로 전압 확립(0 = 부족 전압)","en":"NUV DC link voltage established (0 = undervoltage)"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 경보 릴레이(모든 고장)","en":"ALM alarm relay (any fault)"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 기능 코드 데이터 쓰는 중","en":"BUSY writing function code data"}],"description":{"ko":"형식 [16]","en":"Format [16]"},"ref":"p.5-12 표 5.9, p.5-67","source":0},{"table":"holding-registers","address":2063,"manualAddress":"M15 (080Fh)","type":"u16","name":{"ko":"M15 범용 출력 단자 정보","en":"M15 General-purpose output terminal information"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"}],"description":{"ko":"형식 [15]","en":"Format [15]"},"ref":"p.5-12 표 5.9, p.5-67","source":0},{"table":"holding-registers","address":2064,"manualAddress":"M16 (0810h)","type":"u16","name":{"ko":"M16 최근 경보 내용","en":"M16 Latest alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-65)","en":"Alarm code (format [10], p.5-65)"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2065,"manualAddress":"M17 (0811h)","type":"u16","name":{"ko":"M17 직전 경보 내용","en":"M17 Last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-65)","en":"Alarm code (format [10], p.5-65)"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2066,"manualAddress":"M18 (0812h)","type":"u16","name":{"ko":"M18 2회 전 경보 내용","en":"M18 Second last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-65)","en":"Alarm code (format [10], p.5-65)"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2067,"manualAddress":"M19 (0813h)","type":"u16","name":{"ko":"M19 3회 전 경보 내용","en":"M19 Third last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-65)","en":"Alarm code (format [10], p.5-65)"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2068,"manualAddress":"M20 (0814h)","type":"u16","name":{"ko":"M20 누적 운전 시간","en":"M20 Cumulative operation time"},"unit":"h","access":"r","fc":[3],"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2069,"manualAddress":"M21 (0815h)","type":"u16","name":{"ko":"M21 직류 중간 회로 전압","en":"M21 DC link circuit voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2071,"manualAddress":"M23 (0817h)","type":"u16","name":{"ko":"M23 모델 코드","en":"M23 Model code"},"access":"r","fc":[3],"description":{"ko":"시리즈·세대·모델·전압 계열을 16진 4자리로(형식 [17])","en":"Series, generation, model and voltage series as four hex digits (format [17])"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2072,"manualAddress":"M24 (0818h)","type":"u16","name":{"ko":"M24 용량 코드","en":"M24 Capacity code"},"access":"r","fc":[3],"description":{"ko":"형식 [11]","en":"Format [11]"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2073,"manualAddress":"M25 (0819h)","type":"u16","name":{"ko":"M25 ROM 버전","en":"M25 ROM version"},"access":"r","fc":[3],"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2074,"manualAddress":"M26 (081Ah)","type":"u16","name":{"ko":"M26 전송 오류 처리 코드","en":"M26 Transmission error transaction code"},"access":"r","fc":[3],"description":{"ko":"RS-485 통신 오류 코드(형식 [20])","en":"RS-485 communications error code (format [20])"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2075,"manualAddress":"M27 (081Bh)","type":"s16","name":{"ko":"M27 경보 때 주파수 지령 (p.u.)","en":"M27 Frequency reference on alarm (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-12 표 5.9","source":0},{"table":"holding-registers","address":2079,"manualAddress":"M31 (081Fh)","type":"u16","name":{"ko":"M31 경보 때 주파수 지령","en":"M31 Frequency reference on alarm"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2080,"manualAddress":"M32 (0820h)","type":"s16","name":{"ko":"M32 경보 때 출력 주파수 1 (p.u.)","en":"M32 Output frequency 1 on alarm (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2081,"manualAddress":"M33 (0821h)","type":"s16","name":{"ko":"M33 경보 때 토크 실제값","en":"M33 Torque real value on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2083,"manualAddress":"M35 (0823h)","type":"u16","name":{"ko":"M35 경보 때 출력 주파수","en":"M35 Output frequency on alarm"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2084,"manualAddress":"M36 (0824h)","type":"u16","name":{"ko":"M36 경보 때 입력 전력","en":"M36 Input power on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2085,"manualAddress":"M37 (0825h)","type":"u16","name":{"ko":"M37 경보 때 출력 전류 실효값","en":"M37 Output current effective value on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2087,"manualAddress":"M39 (0827h)","type":"u16","name":{"ko":"M39 경보 때 운전 명령","en":"M39 Operation command on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력","en":"X4 general-purpose input"},{"bit":6,"ko":"X5 범용 입력","en":"X5 general-purpose input"},{"bit":7,"ko":"X6 범용 입력","en":"X6 general-purpose input"},{"bit":8,"ko":"X7 범용 입력","en":"X7 general-purpose input"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"ref":"p.5-13 표 5.10, p.5-67","source":0},{"table":"holding-registers","address":2088,"manualAddress":"M40 (0828h)","type":"u16","name":{"ko":"M40 경보 때 운전 상태","en":"M40 Operation status on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD running forward"},{"bit":1,"ko":"REV 역회전 중","en":"REV running in reverse"},{"bit":2,"ko":"EXT 직류 제동 중(또는 예비 여자 중)","en":"EXT DC braking (or pre-exciting)"},{"bit":3,"ko":"INT 인버터 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중","en":"BRK braking"},{"bit":5,"ko":"NUV 직류 중간 회로 전압 확립(0 = 부족 전압)","en":"NUV DC link voltage established (0 = undervoltage)"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 경보 릴레이(모든 고장)","en":"ALM alarm relay (any fault)"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 기능 코드 데이터 쓰는 중","en":"BUSY writing function code data"}],"ref":"p.5-13 표 5.10, p.5-67","source":0},{"table":"holding-registers","address":2089,"manualAddress":"M41 (0829h)","type":"u16","name":{"ko":"M41 경보 때 출력 단자 정보","en":"M41 Output terminal information on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"}],"ref":"p.5-13 표 5.10, p.5-67","source":0},{"table":"holding-registers","address":2090,"manualAddress":"M42 (082Ah)","type":"u16","name":{"ko":"M42 경보 때 누적 운전 시간","en":"M42 Cumulative operation time on alarm"},"unit":"h","access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2091,"manualAddress":"M43 (082Bh)","type":"u16","name":{"ko":"M43 경보 때 직류 중간 회로 전압","en":"M43 DC link circuit voltage on alarm"},"unit":"V","access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2092,"manualAddress":"M44 (082Ch)","type":"u16","name":{"ko":"M44 경보 때 인버터 내부 공기 온도","en":"M44 Inverter internal air temperature on alarm"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2093,"manualAddress":"M45 (082Dh)","type":"u16","name":{"ko":"M45 경보 때 방열판 온도","en":"M45 Heat sink temperature on alarm"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2094,"manualAddress":"M46 (082Eh)","type":"u16","name":{"ko":"M46 주회로 콘덴서 수명","en":"M46 Life of main circuit capacitor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"출하 때 용량 = 100%","en":"100% = capacity at shipment"},"ref":"p.5-13 표 5.10","source":0},{"table":"holding-registers","address":2097,"manualAddress":"M49 (0831h)","type":"s16","name":{"ko":"M49 입력 단자 [12] 전압 (p.u.)","en":"M49 Input terminal [12] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2098,"manualAddress":"M50 (0832h)","type":"u16","name":{"ko":"M50 입력 단자 [C1] 전류 (p.u.)","en":"M50 Input terminal [C1] current (p.u.)"},"access":"r","fc":[3],"description":{"ko":"0 = 0 mA, 20000 = 20 mA","en":"0 = 0 mA, 20000 = 20 mA"},"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2100,"manualAddress":"M52 (0834h)","type":"s16","name":{"ko":"M52 입력 단자 [32] 전압 (p.u.)","en":"M52 Input terminal [32] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2102,"manualAddress":"M54 (0836h)","type":"s16","name":{"ko":"M54 입력 단자 [V2] 전압 (p.u.)","en":"M54 Input terminal [V2] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2109,"manualAddress":"M61 (083Dh)","type":"u16","name":{"ko":"M61 인버터 내부 공기 온도","en":"M61 Inverter internal air temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2110,"manualAddress":"M62 (083Eh)","type":"u16","name":{"ko":"M62 방열판 온도","en":"M62 Heat sink temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2111,"manualAddress":"M63 (083Fh)","type":"s16","name":{"ko":"M63 부하율","en":"M63 Load factor"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 = 100%","en":"100% = motor rating"},"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2112,"manualAddress":"M64 (0840h)","type":"s16","name":{"ko":"M64 모터 출력","en":"M64 Motor output"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"모터 정격 출력(kW) = 100%","en":"100% = motor rated output (kW)"},"ref":"p.5-14 표 5.11","source":0},{"table":"holding-registers","address":2116,"manualAddress":"M68 (0844h)","type":"s16","name":{"ko":"M68 PID 최종 지령","en":"M68 PID final command"},"access":"r","fc":[3],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-14 표 5.11","source":0}],"notes":[{"ko":"HVAC·AQUA 가 모두 지원하는 S·M 코드 가운데 뜻·단위가 매뉴얼 표에 있는 것만 넣었다. M38 은 최소 단위 1.0 과 형식 [3](0.1)이 달라, M47·M48(수명)은 표 5.10 단위(10 h)와 형식 [74] 를 대조하지 못해, M69(정격 전류)는 용량에 따라 배율이 바뀌어 뺐다. M53 은 표 5.11 이름(입력 단자 [C2] 전류)과 형식 표 5.28 이름(전압)이 달라 뺐다.","en":"Only S and M codes supported by both HVAC and AQUA whose meaning and unit are in the manual tables are included. M38 is left out (step 1.0 vs format [3] = 0.1), M47/M48 (life) because Table 5.10 (10 h) could not be matched with format [74], M69 (rated current) because its scale changes with capacity, and M53 because Table 5.11 calls it input terminal [C2] current while format Table 5.28 says voltage."},{"ko":"형식 [16] 운전 상태의 비트 6 은 비트 그림에서 0(안 씀)인데 아래 표에는 TL(토크 제한 중)로 나와 넣지 않았다 (p.5-67).","en":"Bit 6 of format [16] (operation status) is 0 (unused) in the bit diagram but TL (torque limiting) in the table below it, so it is left out (p.5-67)."},{"ko":"통신으로 운전·주파수 지령을 주려면 H30(링크 기능)과 y98·y99 를 통신 쪽으로 정해야 한다 (p.2-17~2-19). 읽기(M 코드)는 그대로 된다.","en":"To run the drive and give the frequency reference over communications, set H30 (link function) and y98/y99 to communications (pp.2-17-2-19). Reading (M codes) works as is."}],"sources":[{"title":"RS-485 Communication User's Manual (FRENIC-HVAC, FRENIC-AQUA)","publisher":"Fuji Electric","edition":{"ko":"24A7-E-0021b 3판 2015-05","en":"24A7-E-0021b 3rd edition May 2015"},"url":"https://americas.fujielectric.com/files/24A7-E-0021b.pdf","pages":{"ko":"RS-485 설정 p.2-20~2-22, Modbus RTU 메시지 p.3-4~3-5, CRC 예 p.3-22~3-23, 명령 데이터 p.5-2, 모니터 데이터 p.5-11~5-14, 형식 번호 p.5-51~5-52, 형식 사양 p.5-63~5-71","en":"RS-485 settings pp.2-20-2-22, Modbus RTU messages pp.3-4-3-5, CRC example pp.3-22-3-23, command data p.5-2, monitor data pp.5-11-5-14, format numbers pp.5-51-5-52, format specifications pp.5-63-5-71"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"fuji-electric/frenic","manufacturer":{"ko":"후지전기","en":"Fuji Electric"},"model":"FRENIC-Mini/Eco/Multi/MEGA","models":["FRENIC-Mini (C1)","FRENIC-Eco (F1)","FRENIC-Multi (E1)","FRENIC-MEGA (G1)"],"kind":"inverter","title":{"ko":"후지전기 FRENIC-Mini·Eco·Multi·MEGA 인버터 (RS-485 Modbus RTU)","en":"Fuji Electric FRENIC-Mini, Eco, Multi and MEGA inverters (RS-485 Modbus RTU)"},"summary":{"ko":"RS-485 Modbus RTU. 레지스터 주소 = 기능 코드 그룹 × 256 + 번호(S = 07h, M = 08h): 주파수 지령 S05 (0705h), 운전 명령 S06 (0706h), 출력 주파수 M09 (0809h), 운전 상태 M14 (080Eh). 네 시리즈가 모두 지원하는 코드만","en":"RS-485 Modbus RTU. Register address = function code group × 256 + number (S = 07h, M = 08h): frequency reference S05 (0705h), operation command S06 (0706h), output frequency M09 (0809h), operation status M14 (080Eh). Only codes supported by all four series"},"protocols":["rtu"],"comm":{"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"unitRange":[1,247],"maxRegisters":50,"addressing":"zero","notes":[{"ko":"주소 체계: 매뉴얼 CRC 계산 예(p.3-21~3-22)는 국번 1, FC03, 기능 코드 P02(그룹 P = 03h, 번호 02h), 20개 읽기를 01 03 03 02 00 14 E4 41 로 보낸다. 레지스터 주소 = 그룹 코드 × 256 + 번호(0 기준, 표 3.2 p.3-4). CRC 도 계산값과 맞다.","en":"Addressing: the manual's CRC example (pp.3-21-3-22) reads 20 words from function code P02 (group P = 03h, number 02h) at station 1 with 01 03 03 02 00 14 E4 41. Register address = group code × 256 + number (0-based, Table 3.2 p.3-4). The CRC matches calculation."},{"ko":"y04 속도 2400·4800·9600·19200·38400 bps(Mini 는 38400 없음), y06 패리티 0 없음(정지 2비트)·1 짝수·2 홀수(정지 1비트)·3 없음(정지 1비트, Multi·MEGA 만), Modbus RTU 는 8비트 고정 (p.2-23). Modbus RTU 로 쓰려면 y10 = 0 (p.2-24). 출하값은 이 매뉴얼에 없어 비웠다.","en":"y04 baud 2400/4800/9600/19200/38400 bps (no 38400 on Mini); y06 parity 0 none (2 stop bits), 1 even, 2 odd (1 stop bit), 3 none (1 stop bit, Multi/MEGA only); Modbus RTU is fixed at 8 bits (p.2-23). Set y10 = 0 for Modbus RTU (p.2-24). Factory settings are not in this manual and are left empty."},{"ko":"FC03 은 한 번에 50워드(MEGA 100워드)까지. 안 쓰는 기능 코드는 오류 없이 0 으로 읽히고, 한 번의 읽기가 그룹을 넘지 않는다 (p.3-4). 쓰기는 FC06·FC16(50워드, MEGA 100워드) (p.3-5).","en":"FC03 reads up to 50 words (100 on MEGA) at a time. Unused function codes read as 0 without an error, and one read does not cross a group (p.3-4). Writes use FC06 and FC16 (50 words, 100 on MEGA) (p.3-5)."}]},"registers":[{"table":"holding-registers","address":1793,"manualAddress":"S01 (0701h)","type":"s16","name":{"ko":"S01 주파수 지령 (p.u.)","en":"S01 Frequency reference (p.u.)"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = 최대 주파수. S01 이 0 이 아니면 S05 보다 앞선다","en":"±20000 = maximum frequency. When S01 is not 0 it takes precedence over S05"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1797,"manualAddress":"S05 (0705h)","type":"u16","name":{"ko":"S05 주파수 지령","en":"S05 Frequency reference"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":655.35},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1798,"manualAddress":"S06 (0706h)","type":"u16","name":{"ko":"S06 운전 명령","en":"S06 Operation command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력(Mini 없음)","en":"X4 general-purpose input (not on Mini)"},{"bit":6,"ko":"X5 범용 입력(Mini 없음)","en":"X5 general-purpose input (not on Mini)"},{"bit":7,"ko":"X6 범용 입력(MEGA 만)","en":"X6 general-purpose input (MEGA only)"},{"bit":8,"ko":"X7 범용 입력(MEGA 만)","en":"X7 general-purpose input (MEGA only)"},{"bit":9,"ko":"X8 범용 입력(MEGA 만)","en":"X8 general-purpose input (MEGA only)"},{"bit":10,"ko":"X9 범용 입력(MEGA 만)","en":"X9 general-purpose input (MEGA only)"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"description":{"ko":"형식 [14]. 매뉴얼 예: FWD·X1 켬 = 0005h. 비트 15 로 경보를 리셋하려면 1 로 쓴 뒤 다시 0 으로 쓴다","en":"Format [14]. Manual example: FWD and X1 on = 0005h. To reset an alarm with bit 15, write 1 and then 0 again"},"ref":"p.5-2 표 5.2, p.5-51","source":0},{"table":"holding-registers","address":1800,"manualAddress":"S08 (0708h)","type":"u16","name":{"ko":"S08 가속 시간 (F07)","en":"S08 Acceleration time (F07)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"Mini·Eco·Multi 0.0~3600.0 s, MEGA 0.0~6000.0 s. 소수 넷째 자리 아래는 버린다(123.4 → 123.0)","en":"Mini/Eco/Multi 0.0-3600.0 s, MEGA 0.0-6000.0 s. Digits below the fourth significant digit are dropped (123.4 -> 123.0)"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1801,"manualAddress":"S09 (0709h)","type":"u16","name":{"ko":"S09 감속 시간 (F08)","en":"S09 Deceleration time (F08)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"Mini·Eco·Multi 0.0~3600.0 s, MEGA 0.0~6000.0 s. 소수 넷째 자리 아래는 버린다(123.4 → 123.0)","en":"Mini/Eco/Multi 0.0-3600.0 s, MEGA 0.0-6000.0 s. Digits below the fourth significant digit are dropped (123.4 -> 123.0)"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1805,"manualAddress":"S13 (070Dh)","type":"s16","name":{"ko":"S13 PID 지령","en":"S13 PID command"},"access":"rw","fc":[3,6,16],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-2 표 5.2","source":0},{"table":"holding-registers","address":1806,"manualAddress":"S14 (070Eh)","type":"u16","name":{"ko":"S14 경보 리셋 명령","en":"S14 Alarm reset command"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"경보 리셋","en":"Alarm reset"}],"description":{"ko":"1 을 쓰면 리셋한다. 읽으면 늘 0","en":"Writing 1 resets the alarm. Always reads 0"},"ref":"p.5-3, p.5-4","source":0},{"table":"holding-registers","address":2049,"manualAddress":"M01 (0801h)","type":"s16","name":{"ko":"M01 주파수 지령 (p.u.) (최종 지령)","en":"M01 Frequency reference (p.u.) (final command)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2053,"manualAddress":"M05 (0805h)","type":"u16","name":{"ko":"M05 주파수 지령 (최종 지령)","en":"M05 Frequency reference (final command)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2054,"manualAddress":"M06 (0806h)","type":"s16","name":{"ko":"M06 출력 주파수 1 (p.u.)","en":"M06 Output frequency 1 (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수, 슬립 보상 전","en":"±20000 = maximum frequency, before slip compensation"},"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2057,"manualAddress":"M09 (0809h)","type":"u16","name":{"ko":"M09 출력 주파수","en":"M09 Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Modbus RTU 는 형식 [22](0.00~655.35 Hz, 부호 없음)","en":"Modbus RTU uses format [22] (0.00-655.35 Hz, unsigned)"},"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2058,"manualAddress":"M10 (080Ah)","type":"u16","name":{"ko":"M10 입력 전력","en":"M10 Input power"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"«적용 모터 공칭 출력» = 100%","en":"100% = nominal applicable motor output"},"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2059,"manualAddress":"M11 (080Bh)","type":"u16","name":{"ko":"M11 출력 전류 실효값","en":"M11 Output current effective value"},"unit":"%","scale":0.01,"access":"r","fc":[3],"description":{"ko":"인버터 정격 전류 = 100%","en":"100% = inverter rated current"},"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2060,"manualAddress":"M12 (080Ch)","type":"u16","name":{"ko":"M12 출력 전압 실효값","en":"M12 Output voltage effective value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"형식 [3](0.1 단위)이지만 소수점 아래 값은 없다(1.0 V 단위로 바뀜)","en":"Format [3] (0.1 units) but there is no fractional part (changes in 1.0 V steps)"},"ref":"p.5-9 표 5.8","source":0},{"table":"holding-registers","address":2061,"manualAddress":"M13 (080Dh)","type":"u16","name":{"ko":"M13 운전 명령 (최종 지령)","en":"M13 Operation command (final command)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력(Mini 없음)","en":"X4 general-purpose input (not on Mini)"},{"bit":6,"ko":"X5 범용 입력(Mini 없음)","en":"X5 general-purpose input (not on Mini)"},{"bit":7,"ko":"X6 범용 입력(MEGA 만)","en":"X6 general-purpose input (MEGA only)"},{"bit":8,"ko":"X7 범용 입력(MEGA 만)","en":"X7 general-purpose input (MEGA only)"},{"bit":9,"ko":"X8 범용 입력(MEGA 만)","en":"X8 general-purpose input (MEGA only)"},{"bit":10,"ko":"X9 범용 입력(MEGA 만)","en":"X9 general-purpose input (MEGA only)"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"description":{"ko":"형식 [14] — 키패드·단자·통신을 합친 최종 명령","en":"Format [14]: final command from keypad, terminals and communications"},"ref":"p.5-10 표 5.9, p.5-51","source":0},{"table":"holding-registers","address":2062,"manualAddress":"M14 (080Eh)","type":"u16","name":{"ko":"M14 운전 상태","en":"M14 Operation status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD running forward"},{"bit":1,"ko":"REV 역회전 중","en":"REV running in reverse"},{"bit":2,"ko":"EXT 직류 제동 중(또는 예비 여자 중)","en":"EXT DC braking (or pre-exciting)"},{"bit":3,"ko":"INT 인버터 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중(Mini 는 늘 0)","en":"BRK braking (always 0 on Mini)"},{"bit":5,"ko":"NUV 직류 중간 회로 전압 확립(0 = 부족 전압)","en":"NUV DC link voltage established (0 = undervoltage)"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 경보 릴레이(모든 고장)","en":"ALM alarm relay (any fault)"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 기능 코드 데이터 쓰는 중","en":"BUSY writing function code data"}],"description":{"ko":"형식 [16]","en":"Format [16]"},"ref":"p.5-10 표 5.9, p.5-51","source":0},{"table":"holding-registers","address":2063,"manualAddress":"M15 (080Fh)","type":"u16","name":{"ko":"M15 범용 출력 단자 정보","en":"M15 General-purpose output terminal information"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"},{"bit":12,"ko":"Y1A 릴레이 옵션 출력(Eco 만)","en":"Y1A relay option output (Eco only)"},{"bit":13,"ko":"Y2A 릴레이 옵션 출력(Eco 만)","en":"Y2A relay option output (Eco only)"},{"bit":14,"ko":"Y3A 릴레이 옵션 출력(Eco 만)","en":"Y3A relay option output (Eco only)"}],"description":{"ko":"형식 [15]","en":"Format [15]"},"ref":"p.5-10 표 5.9, p.5-51","source":0},{"table":"holding-registers","address":2064,"manualAddress":"M16 (0810h)","type":"u16","name":{"ko":"M16 최근 경보 내용","en":"M16 Latest alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-48)","en":"Alarm code (format [10], p.5-48)"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2065,"manualAddress":"M17 (0811h)","type":"u16","name":{"ko":"M17 직전 경보 내용","en":"M17 Last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-48)","en":"Alarm code (format [10], p.5-48)"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2066,"manualAddress":"M18 (0812h)","type":"u16","name":{"ko":"M18 2회 전 경보 내용","en":"M18 Second last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-48)","en":"Alarm code (format [10], p.5-48)"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2067,"manualAddress":"M19 (0813h)","type":"u16","name":{"ko":"M19 3회 전 경보 내용","en":"M19 Third last alarm contents"},"access":"r","fc":[3],"description":{"ko":"경보 코드(형식 [10], p.5-48)","en":"Alarm code (format [10], p.5-48)"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2068,"manualAddress":"M20 (0814h)","type":"u16","name":{"ko":"M20 누적 운전 시간","en":"M20 Cumulative operation time"},"unit":"h","access":"r","fc":[3],"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2069,"manualAddress":"M21 (0815h)","type":"u16","name":{"ko":"M21 직류 중간 회로 전압","en":"M21 DC link circuit voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2071,"manualAddress":"M23 (0817h)","type":"u16","name":{"ko":"M23 모델 코드","en":"M23 Model code"},"access":"r","fc":[3],"description":{"ko":"시리즈·세대·모델·전압 계열을 16진 4자리로(형식 [17])","en":"Series, generation, model and voltage series as four hex digits (format [17])"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2072,"manualAddress":"M24 (0818h)","type":"u16","name":{"ko":"M24 용량 코드","en":"M24 Capacity code"},"access":"r","fc":[3],"description":{"ko":"형식 [11]","en":"Format [11]"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2073,"manualAddress":"M25 (0819h)","type":"u16","name":{"ko":"M25 ROM 버전","en":"M25 ROM version"},"access":"r","fc":[3],"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2074,"manualAddress":"M26 (081Ah)","type":"u16","name":{"ko":"M26 전송 오류 처리 코드","en":"M26 Transmission error transaction code"},"access":"r","fc":[3],"description":{"ko":"RS-485 통신 오류 코드(형식 [20])","en":"RS-485 communications error code (format [20])"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2075,"manualAddress":"M27 (081Bh)","type":"s16","name":{"ko":"M27 경보 때 주파수 지령 (p.u.)","en":"M27 Frequency reference on alarm (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-10 표 5.9","source":0},{"table":"holding-registers","address":2079,"manualAddress":"M31 (081Fh)","type":"u16","name":{"ko":"M31 경보 때 주파수 지령","en":"M31 Frequency reference on alarm"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-11 표 5.10","source":0},{"table":"holding-registers","address":2080,"manualAddress":"M32 (0820h)","type":"s16","name":{"ko":"M32 경보 때 출력 주파수 1 (p.u.)","en":"M32 Output frequency 1 on alarm (p.u.)"},"access":"r","fc":[3],"description":{"ko":"±20000 = 최대 주파수","en":"±20000 = maximum frequency"},"ref":"p.5-11 표 5.10","source":0},{"table":"holding-registers","address":2083,"manualAddress":"M35 (0823h)","type":"u16","name":{"ko":"M35 경보 때 출력 주파수","en":"M35 Output frequency on alarm"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.5-11 표 5.10","source":0},{"table":"holding-registers","address":2084,"manualAddress":"M36 (0824h)","type":"u16","name":{"ko":"M36 경보 때 입력 전력","en":"M36 Input power on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-11 표 5.10","source":0},{"table":"holding-registers","address":2085,"manualAddress":"M37 (0825h)","type":"u16","name":{"ko":"M37 경보 때 출력 전류 실효값","en":"M37 Output current effective value on alarm"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.5-11 표 5.10","source":0},{"table":"holding-registers","address":2087,"manualAddress":"M39 (0827h)","type":"u16","name":{"ko":"M39 경보 때 운전 명령","en":"M39 Operation command on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 명령","en":"FWD forward run command"},{"bit":1,"ko":"REV 역회전 명령","en":"REV reverse run command"},{"bit":2,"ko":"X1 범용 입력","en":"X1 general-purpose input"},{"bit":3,"ko":"X2 범용 입력","en":"X2 general-purpose input"},{"bit":4,"ko":"X3 범용 입력","en":"X3 general-purpose input"},{"bit":5,"ko":"X4 범용 입력(Mini 없음)","en":"X4 general-purpose input (not on Mini)"},{"bit":6,"ko":"X5 범용 입력(Mini 없음)","en":"X5 general-purpose input (not on Mini)"},{"bit":7,"ko":"X6 범용 입력(MEGA 만)","en":"X6 general-purpose input (MEGA only)"},{"bit":8,"ko":"X7 범용 입력(MEGA 만)","en":"X7 general-purpose input (MEGA only)"},{"bit":9,"ko":"X8 범용 입력(MEGA 만)","en":"X8 general-purpose input (MEGA only)"},{"bit":10,"ko":"X9 범용 입력(MEGA 만)","en":"X9 general-purpose input (MEGA only)"},{"bit":13,"ko":"XF(FWD) 범용 입력","en":"XF (FWD) general-purpose input"},{"bit":14,"ko":"XR(REV) 범용 입력","en":"XR (REV) general-purpose input"},{"bit":15,"ko":"RST 경보 리셋","en":"RST alarm reset"}],"ref":"p.5-11 표 5.10, p.5-51","source":0},{"table":"holding-registers","address":2088,"manualAddress":"M40 (0828h)","type":"u16","name":{"ko":"M40 경보 때 운전 상태","en":"M40 Operation status on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD running forward"},{"bit":1,"ko":"REV 역회전 중","en":"REV running in reverse"},{"bit":2,"ko":"EXT 직류 제동 중(또는 예비 여자 중)","en":"EXT DC braking (or pre-exciting)"},{"bit":3,"ko":"INT 인버터 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중(Mini 는 늘 0)","en":"BRK braking (always 0 on Mini)"},{"bit":5,"ko":"NUV 직류 중간 회로 전압 확립(0 = 부족 전압)","en":"NUV DC link voltage established (0 = undervoltage)"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 경보 릴레이(모든 고장)","en":"ALM alarm relay (any fault)"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 기능 코드 데이터 쓰는 중","en":"BUSY writing function code data"}],"ref":"p.5-11 표 5.10, p.5-51","source":0},{"table":"holding-registers","address":2089,"manualAddress":"M41 (0829h)","type":"u16","name":{"ko":"M41 경보 때 출력 단자 정보","en":"M41 Output terminal information on alarm"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"Y1 범용 출력","en":"Y1 general-purpose output"},{"bit":1,"ko":"Y2 범용 출력","en":"Y2 general-purpose output"},{"bit":2,"ko":"Y3 범용 출력","en":"Y3 general-purpose output"},{"bit":3,"ko":"Y4 범용 출력","en":"Y4 general-purpose output"},{"bit":4,"ko":"Y5 범용 출력","en":"Y5 general-purpose output"},{"bit":8,"ko":"30 경보 출력(범용 출력)","en":"30 alarm output (general-purpose output)"},{"bit":12,"ko":"Y1A 릴레이 옵션 출력(Eco 만)","en":"Y1A relay option output (Eco only)"},{"bit":13,"ko":"Y2A 릴레이 옵션 출력(Eco 만)","en":"Y2A relay option output (Eco only)"},{"bit":14,"ko":"Y3A 릴레이 옵션 출력(Eco 만)","en":"Y3A relay option output (Eco only)"}],"ref":"p.5-11 표 5.10, p.5-51","source":0},{"table":"holding-registers","address":2090,"manualAddress":"M42 (082Ah)","type":"u16","name":{"ko":"M42 경보 때 누적 운전 시간","en":"M42 Cumulative operation time on alarm"},"unit":"h","access":"r","fc":[3],"ref":"p.5-11 표 5.10","source":0},{"table":"holding-registers","address":2091,"manualAddress":"M43 (082Bh)","type":"u16","name":{"ko":"M43 경보 때 직류 중간 회로 전압","en":"M43 DC link circuit voltage on alarm"},"unit":"V","access":"r","fc":[3],"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2093,"manualAddress":"M45 (082Dh)","type":"u16","name":{"ko":"M45 경보 때 방열판 온도","en":"M45 Heat sink temperature on alarm"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2094,"manualAddress":"M46 (082Eh)","type":"u16","name":{"ko":"M46 주회로 콘덴서 수명","en":"M46 Life of main circuit capacitor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"출하 때 용량 = 100%","en":"100% = capacity at shipment"},"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2095,"manualAddress":"M47 (082Fh)","type":"u16","name":{"ko":"M47 제어 기판 전해 콘덴서 수명","en":"M47 Life of PC board electrolytic capacitor"},"unit":"h","access":"r","fc":[3],"description":{"ko":"Multi·MEGA 는 65535 h 에서 멈춘다","en":"Multi/MEGA stop at 65535 h"},"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2096,"manualAddress":"M48 (0830h)","type":"u16","name":{"ko":"M48 방열판 수명","en":"M48 Life of heat sink"},"unit":"h","access":"r","fc":[3],"description":{"ko":"Multi·MEGA 는 65535 h 에서 멈춘다","en":"Multi/MEGA stop at 65535 h"},"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2097,"manualAddress":"M49 (0831h)","type":"s16","name":{"ko":"M49 입력 단자 [12] 전압 (p.u.)","en":"M49 Input terminal [12] voltage (p.u.)"},"access":"r","fc":[3],"description":{"ko":"-20000 = -10 V, 20000 = 10 V","en":"-20000 = -10 V, 20000 = 10 V"},"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2098,"manualAddress":"M50 (0832h)","type":"u16","name":{"ko":"M50 입력 단자 [C1] 전류 (p.u.)","en":"M50 Input terminal [C1] current (p.u.)"},"access":"r","fc":[3],"description":{"ko":"0 = 0 mA, 20000 = 20 mA","en":"0 = 0 mA, 20000 = 20 mA"},"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2110,"manualAddress":"M62 (083Eh)","type":"u16","name":{"ko":"M62 방열판 온도","en":"M62 Heat sink temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.5-12 표 5.11","source":0},{"table":"holding-registers","address":2116,"manualAddress":"M68 (0844h)","type":"s16","name":{"ko":"M68 PID 최종 지령","en":"M68 PID final command"},"access":"r","fc":[3],"description":{"ko":"±20000 = ±100%","en":"±20000 = ±100%"},"ref":"p.5-13 표 5.12","source":0}],"notes":[{"ko":"Mini·Eco·Multi·MEGA 네 시리즈가 모두 지원(표의 ○)하는 S·M 코드만 넣었다. 토크·모터 온도·내부 공기 온도·부하율 등 일부 시리즈만 지원하는 코드는 뺐다. M38(경보 때 출력 전압)은 표 5.10 의 최소 단위 1.0 과 형식 [3](0.1)이 달라 뺐고, M69(인버터 정격 전류)는 용량에 따라 0.01 A·0.1 A 로 배율이 바뀌어 뺐다.","en":"Only S and M codes supported by all four series (○ in the tables) are included. Codes supported by only some series (torque, motor temperature, internal air temperature, load factor and so on) are left out. M38 (output voltage on alarm) is left out because Table 5.10 gives a 1.0 step while its format [3] is 0.1, and M69 (inverter rated current) because its scale changes between 0.01 A and 0.1 A with capacity."},{"ko":"형식 [16] 운전 상태의 비트 6 은 비트 그림에서 0(안 씀)인데 아래 표에는 TL(토크 제한 중, Multi·MEGA)로 나와 넣지 않았다 (p.5-51).","en":"Bit 6 of format [16] (operation status) is 0 (unused) in the bit diagram but TL (torque limiting, Multi/MEGA) in the table below it, so it is left out (p.5-51)."},{"ko":"통신으로 운전·주파수 지령을 주려면 H30(링크 기능)과 y98·y99 를 통신 쪽으로 정해야 한다 (p.2-19~2-21). 읽기(M 코드)는 그대로 된다.","en":"To run the drive and give the frequency reference over communications, set H30 (link function) and y98/y99 to communications (pp.2-19-2-21). Reading (M codes) works as is."}],"sources":[{"title":"RS-485 User's Manual (FRENIC-Mini, FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA)","publisher":"Fuji Electric","edition":{"ko":"24A7-E-0082 (MEH448) 5판 2009-07, 2014-06 인쇄","en":"24A7-E-0082 (MEH448) 5th edition July 2009, printed 2014-06"},"url":"https://americas.fujielectric.com/files/RS-485_Users_Manual_24A7-E-0082.pdf","pages":{"ko":"RS-485 설정 p.2-22~2-24, Modbus RTU 메시지 p.3-4~3-5, CRC 예 p.3-21~3-22, 명령 데이터 p.5-2~5-8, 모니터 데이터 p.5-9~5-14, 형식 번호 p.5-40~5-41, 형식 사양 p.5-47~5-55","en":"RS-485 settings pp.2-22-2-24, Modbus RTU messages pp.3-4-3-5, CRC example pp.3-21-3-22, command data pp.5-2-5-8, monitor data pp.5-9-5-14, format numbers pp.5-40-5-41, format specifications pp.5-47-5-55"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"fuji-electric/pxh","manufacturer":{"ko":"후지전기","en":"Fuji Electric"},"model":"PXH","models":["PXH9"],"kind":"temperature-controller","title":{"ko":"후지전기 PXH 디지털 조절계 (RS-485 Modbus RTU)","en":"Fuji Electric PXH digital controller (RS-485 Modbus RTU)"},"summary":{"ko":"PXH9 의 RS-485(단자 14·15·16)와 PC 로더 포트. 모든 값이 2워드(하위 워드 먼저). 상태·PV1·SV1·DV1·MV1·입력 이상(04, 30257~), AT·경보 래치·리셋·로컬 SV·PID·PV1 범위·FIX(03·06·10)","en":"RS-485 (terminals 14, 15, 16) and PC loader port of the PXH9. Every value is two words (low word first). Status, PV1, SV1, DV1, MV1, input error (04, from 30257); AT, alarm unlatch, reset, local SV, PID, PV1 range, FIX (03, 06, 10)"},"protocols":["rtu"],"comm":{"baud":38400,"bauds":[9600,19200,38400],"dataBits":8,"parity":"odd","stopBits":1,"unit":1,"unitRange":[1,255],"order":"CDAB","maxRegisters":32,"addressing":"plc","notes":[{"ko":"주소 체계: 프레임 주소 = 번호의 아래 네 자리 − 1(인쇄 p.9). 예: 01 03 08 30 00 02 C6 64(42097 PV1F), 01 04 01 02 00 02 D1 F7(30259 PV1), 01 06 02 82 03 E8 28 E4·01 10 02 82 00 06 … B6 D8(40643 P1~), 응답 01 03 04 0F A0 00 00 F9 05·01 04 04 38 80 00 01 36 CC·01 10 02 82 00 06 E1 9B(인쇄 p.18~23). 모두 CRC 가 계산값과 같다.","en":"Addressing: frame address = lower four digits of the number − 1 (printed p.9). Examples: 01 03 08 30 00 02 C6 64 (42097 PV1F), 01 04 01 02 00 02 D1 F7 (30259 PV1), 01 06 02 82 03 E8 28 E4 and 01 10 02 82 00 06 … B6 D8 (40643 P1-), replies 01 03 04 0F A0 00 00 F9 05, 01 04 04 38 80 00 01 36 CC, 01 10 02 82 00 06 E1 9B (printed pp.18-23). All CRCs match calculation."},{"ko":"모든 데이터가 2워드이고 하위 워드를 먼저 보낸다(99999 = 86 9F 00 01, 인쇄 p.17). 06h 로는 하위 워드만 쓸 수 있다(인쇄 p.12). 함수 03·04·06·10h, 한 번에 03h·10h 32워드, 04h 15워드.","en":"All data is two words with the low word sent first (99999 = 86 9F 00 01, printed p.17). 06h can write only the low word (printed p.12). Functions 03, 04, 06 and 10h; up to 32 words for 03h/10h, 15 for 04h."},{"ko":"출하값(인쇄 p.6): RS-485 38400 bps·데이터 8·정지 1·홀수 패리티·국번 1(STN4 0~255, 0 = 통신 정지). 바꾼 뒤 전원을 다시 넣는다. PC 로더 포트는 국번 1 고정.","en":"Defaults (printed p.6): RS-485 38400 bps, 8 data bits, 1 stop bit, odd parity, station 1 (STN4 0-255, 0 stops communication). Cycle power after changing. The PC loader port is fixed at station 1."}]},"registers":[{"table":"input-registers","address":256,"manualAddress":"30257","type":"s32","order":"CDAB","name":{"ko":"제어 모드 상태 (MODE1)","en":"Control mode status (MODE1)"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"이상","en":"Fault"},{"bit":1,"ko":"대기","en":"Standby"},{"bit":2,"ko":"리모트 확인","en":"Remote ack"},{"bit":3,"ko":"자동 아님","en":"Other than auto"},{"bit":4,"ko":"자동 모드 요청","en":"Auto mode request"},{"bit":5,"ko":"리모트 모드 요청","en":"Remote mode request"},{"bit":6,"ko":"오토 튜닝 중","en":"Auto-tuning"},{"bit":7,"ko":"보통 운전 상태","en":"Normal operation"},{"bit":8,"ko":"PV 트래킹","en":"PV tracking"},{"bit":9,"ko":"로컬 SV","en":"Local SV"},{"bit":10,"ko":"리모트 SV","en":"Remote SV"},{"bit":11,"ko":"로컬 + PV 트래킹","en":"Local + PV tracking"},{"bit":12,"ko":"강제 수동","en":"Forced manual"},{"bit":13,"ko":"EX-MV","en":"EX-MV"},{"bit":14,"ko":"수동 모드","en":"Manual mode"}],"ref":"인쇄 p.49 (PDF p.52)","source":0},{"table":"input-registers","address":258,"manualAddress":"30259","type":"s32","order":"CDAB","name":{"ko":"PV1 (제어에 쓰는 PV)","en":"PV1 (process value used for control)"},"access":"r","fc":[4],"description":{"ko":"매뉴얼 예 01 04 01 02 00 02 D1 F7 → 38 80 00 01 = 00013880h = 80000(PV1D = 2 → 800.00 ℃), 응답 CRC 36 CC. 입력 이상이면 범위의 105 %·−5 %","en":"Manual example 01 04 01 02 00 02 D1 F7 → 38 80 00 01 = 00013880h = 80000 (PV1D = 2 → 800.00 °C), reply CRC 36 CC. On input error, 105 % or −5 % of the range"},"ref":"인쇄 p.20 (PDF p.23), 인쇄 p.28 (PDF p.31), 인쇄 p.49 (PDF p.52)","source":0},{"table":"input-registers","address":260,"manualAddress":"30261","type":"s32","order":"CDAB","name":{"ko":"SV1 (사용 중 SV)","en":"SV1 (setpoint in use)"},"access":"r","fc":[4],"description":{"ko":"공학 단위 정수, 소수점 자리는 PV1D(42101) 또는 UCD1(제어 형식 TPLT 에 따라)","en":"Engineering-unit integer; decimal places from PV1D (42101) or UCD1, depending on control type TPLT"},"ref":"인쇄 p.28 (PDF p.31), 인쇄 p.49 (PDF p.52)","source":0},{"table":"input-registers","address":262,"manualAddress":"30263","type":"s32","order":"CDAB","name":{"ko":"DV1 (사용 중 편차)","en":"DV1 (deviation in use)"},"access":"r","fc":[4],"description":{"ko":"공학 단위 정수, 소수점 자리는 PV1D(42101) 또는 UCD1(제어 형식 TPLT 에 따라)","en":"Engineering-unit integer; decimal places from PV1D (42101) or UCD1, depending on control type TPLT"},"ref":"인쇄 p.28 (PDF p.31), 인쇄 p.49 (PDF p.52)","source":0},{"table":"input-registers","address":264,"manualAddress":"30265","type":"s32","order":"CDAB","name":{"ko":"MV1 (사용 중 조작량)","en":"MV1 (manipulated value in use)"},"unit":"%","scale":0.1,"access":"r","fc":[4],"range":{"min":-25,"max":125},"ref":"인쇄 p.28 (PDF p.31), 인쇄 p.49 (PDF p.52)","source":0},{"table":"input-registers","address":268,"manualAddress":"30269","type":"s32","order":"CDAB","name":{"ko":"FAULT1 (입력 이상 상태)","en":"FAULT1 (input error status)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"이상 없음","en":"Normal"},{"value":1,"ko":"오버","en":"Over"},{"value":2,"ko":"언더","en":"Under"}],"ref":"인쇄 p.28 (PDF p.31), 인쇄 p.49 (PDF p.52)","source":0},{"table":"holding-registers","address":20,"manualAddress":"40021","type":"s32","order":"CDAB","name":{"ko":"AT (오토 튜닝 명령)","en":"AT (auto-tuning command)"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"쓰기: AT 정지 / 읽기: 동작 안 함","en":"Write: stop AT / read: not active"},{"value":1,"ko":"쓰기: AT 실행 / 읽기: 동작 중","en":"Write: execute AT / read: active"}],"ref":"인쇄 p.30 (PDF p.33)","source":0},{"table":"holding-registers","address":32,"manualAddress":"40033","type":"s32","order":"CDAB","name":{"ko":"LACH (경보 래치 해제)","en":"LACH (alarm unlatch)"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"쓰기: 효과 없음 / 읽기: 래치됨","en":"Write: no effect / read: latched"},{"value":1,"ko":"쓰기: 래치 해제 / 읽기: 해제됨","en":"Write: unlatch / read: unlatched"}],"ref":"인쇄 p.30 (PDF p.33)","source":0},{"table":"holding-registers","address":96,"manualAddress":"40097","type":"s32","order":"CDAB","name":{"ko":"RES (리셋 명령)","en":"RES (reset command)"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"쓰기: 효과 없음 / 읽기: 동작 중","en":"Write: no effect / read: operating normally"},{"value":1,"ko":"쓰기: 리셋 실행 / 읽기: 리셋 중","en":"Write: execute reset / read: being reset"}],"description":{"ko":"입력 범위 설정을 바꾼 뒤 전원을 다시 넣는 대신 1 을 쓴다(인쇄 p.24)","en":"Write 1 instead of cycling power after changing the input range (printed p.24)"},"ref":"인쇄 p.24 (PDF p.27), 인쇄 p.30 (PDF p.33)","source":0},{"table":"holding-registers","address":640,"manualAddress":"40641","type":"s32","order":"CDAB","name":{"ko":"SV_L1 (로컬 SV)","en":"SV_L1 (local SV)"},"access":"rw","fc":[3,16],"description":{"ko":"공학 단위 정수, 소수점 자리는 PV1D(42101) 또는 UCD1(제어 형식 TPLT 에 따라)","en":"Engineering-unit integer; decimal places from PV1D (42101) or UCD1, depending on control type TPLT"},"ref":"인쇄 p.25 (PDF p.28), 인쇄 p.31 (PDF p.34)","source":0},{"table":"holding-registers","address":642,"manualAddress":"40643","type":"s32","order":"CDAB","name":{"ko":"P1 (비례대)","en":"P1 (proportional band)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,16],"range":{"min":0,"max":999.9},"description":{"ko":"매뉴얼 예 01 06 02 82 03 E8 28 E4(100.0 — 06h 는 하위 워드만), 01 10 02 82 00 06 0C 03 E8 00 00 00 64 00 00 00 32 00 00 B6 D8(P1·I1·D1)","en":"Manual examples 01 06 02 82 03 E8 28 E4 (100.0; 06h writes the low word only), 01 10 02 82 00 06 0C 03 E8 00 00 00 64 00 00 00 32 00 00 B6 D8 (P1, I1, D1)"},"ref":"인쇄 p.21~23 (PDF p.24~26), 인쇄 p.31 (PDF p.34)","source":0},{"table":"holding-registers","address":644,"manualAddress":"40645","type":"s32","order":"CDAB","name":{"ko":"I1 (적분 시간)","en":"I1 (integral time)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,16],"range":{"min":0,"max":3200},"ref":"인쇄 p.31 (PDF p.34)","source":0},{"table":"holding-registers","address":646,"manualAddress":"40647","type":"s32","order":"CDAB","name":{"ko":"D1 (미분 시간)","en":"D1 (derivative time)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,16],"range":{"min":0,"max":999.9},"ref":"인쇄 p.31 (PDF p.34)","source":0},{"table":"holding-registers","address":2096,"manualAddress":"42097","type":"s32","order":"CDAB","name":{"ko":"PV1F (PV1 풀 스케일)","en":"PV1F (PV1 full scale)"},"access":"rw","fc":[3,16],"description":{"ko":"매뉴얼 예 01 03 08 30 00 02 C6 64 → 0F A0 00 00 = 4000, 응답 CRC F9 05. 바꾼 뒤 FIX 와 리셋(또는 전원 재투입)","en":"Manual example 01 03 08 30 00 02 C6 64 → 0F A0 00 00 = 4000, reply CRC F9 05. After changing, FIX and reset (or power cycle)"},"ref":"인쇄 p.18 (PDF p.21), 인쇄 p.24 (PDF p.27), 인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":2098,"manualAddress":"42099","type":"s32","order":"CDAB","name":{"ko":"PV1B (PV1 베이스 스케일)","en":"PV1B (PV1 base scale)"},"access":"rw","fc":[3,16],"ref":"인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":2100,"manualAddress":"42101","type":"s32","order":"CDAB","name":{"ko":"PV1D (PV1 소수점 위치)","en":"PV1D (PV1 decimal point position)"},"access":"rw","fc":[3,16],"range":{"min":0,"max":3},"description":{"ko":"바꾸면 PV1F·PV1B 가 자동으로 바뀐다(예 0~400 → 0.0~400.0)","en":"Changing it updates PV1F and PV1B automatically (e.g. 0-400 → 0.0-400.0)"},"ref":"인쇄 p.24 (PDF p.27), 인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":3152,"manualAddress":"43153","type":"s32","order":"CDAB","name":{"ko":"FIX 명령 (비휘발 메모리 저장)","en":"FIX command (save to non-volatile memory)"},"access":"rw","fc":[3,16],"values":[{"value":0,"ko":"읽기: FIX 아님(끝남)","en":"Read: no FIX (finished)"},{"value":1,"ko":"쓰기: FIX 실행","en":"Write: execute FIX"}],"description":{"ko":"순서(그림 5-4): 03h 로 0 인지 읽기 → 06h 로 1 쓰기 → 0 이 될 때까지 읽기. 5초~3분 걸리고 그동안 전원을 끄지 않는다. 쓰기 횟수 한도 100,000회","en":"Procedure (Fig. 5-4): read 0 with 03h → write 1 with 06h → read until 0. Takes 5 s to 3 min; do not power off meanwhile. 100,000-write limit"},"ref":"인쇄 p.16 (PDF p.19), 인쇄 p.43 (PDF p.46)","source":0}],"notes":[{"ko":"주소표(인쇄 p.30~50)는 PDF 글자 칸이 줄마다 어긋나 있어, 프레임 예·소수점 표(인쇄 p.25~28)·본문 설명으로 이름을 맞출 수 있는 항목만 넣었다. 경보 설정(40257~)·팔레트·램프/소크 등은 뺐다.","en":"The address map (printed pp.30-50) has text columns shifted line by line in the PDF, so only items whose names could be matched by frame examples, the decimal point tables (printed pp.25-28) or the text are included. Alarm settings (40257-), palettes, ramp/soak etc. are left out."},{"ko":"FIX 하지 않으면 통신으로 쓴 값은 전원을 끄면 사라진다(인쇄 p.16). 쪽 번호는 인쇄 쪽(PDF = 인쇄 + 3).","en":"Without FIX, values written over communication are lost at power-off (printed p.16). Page numbers are printed pages (PDF = printed + 3)."}],"sources":[{"title":"PXH Digital Controller Communication Functions (MODBUS) — Instruction Manual","publisher":"Fuji Electric","edition":{"ko":"INP-TN514207c-E","en":"INP-TN514207c-E"},"url":"https://americas.fujielectric.com/wp-content/uploads/2018/12/PXH-Digital-Controller-Communication-FunctionsMODBUS-TN514207c-E-.pdf","pages":{"ko":"인쇄 p.6 통신 설정, p.9~23 프로토콜·예, p.24~29 데이터 형식, p.30~50 주소표 (PDF p.9, 12~26, 27~32, 33~53)","en":"printed p.6 settings, pp.9-23 protocol and examples, pp.24-29 data format, pp.30-50 address map (PDF p.9, 12-26, 27-32, 33-53)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"fuji-electric/pxr","manufacturer":{"ko":"후지전기","en":"Fuji Electric"},"model":"PXR","models":["PXR3","PXR4","PXR5","PXR9"],"kind":"temperature-controller","title":{"ko":"후지전기 PXR 온도 조절기 (RS-485 Modbus RTU)","en":"Fuji Electric PXR temperature controller (RS-485 Modbus RTU)"},"summary":{"ko":"Micro Controller X(PXR3·4·5·9) 통신 옵션. 같은 값을 두 표로 준다 — 내부 계산값(입력 범위의 %, 30001·40001~)과 공학 단위(+1000: 31001·41001~). PV·SV·DV·MV·경보 상태(04), SV·PID·입력 범위·경보 설정(03·06·10), FIX 코일 00001","en":"Communication option of Micro Controller X (PXR3, 4, 5, 9). The same data comes in two tables: internal values (% of input range, 30001/40001-) and engineering units (+1000: 31001/41001-). PV, SV, DV, MV and alarm status (04); SV, PID, input range and alarm settings (03, 06, 10); FIX coil 00001"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[9600],"dataBits":8,"parity":"odd","stopBits":1,"unitRange":[1,255],"maxRegisters":60,"addressing":"plc","notes":[{"ko":"주소 체계: 프레임 주소 = 번호의 아래 네 자리 − 1(인쇄 p.8). 예: 01 01 00 00 00 01 FD CA(코일 00001), 1F 02 00 0C 00 02 3A 76(10013~), 02 03 00 1E 00 02 A4 3E(40031~), 02 03 04 06 00 02 25 09(41031~), 01 04 00 00 00 01 31 CA(30001), 01 04 03 E8 00 01 B1 BA(31001), 01 05 00 00 FF 00 8C 3A, 01 06 00 05 03 E8 99 75(40006), 01 10 00 05 00 03 06 03 E8 00 64 00 32 56 BE(인쇄 p.16~27). 요청과 응답 CRC 는 계산값과 같다 — 마지막 31001 응답(01 04 02 01 4F)만 CRC 를 앞 예의 38 32 로 적었다(계산 F9 54).","en":"Addressing: frame address = lower four digits of the number − 1 (printed p.8). Examples: 01 01 00 00 00 01 FD CA (coil 00001), 1F 02 00 0C 00 02 3A 76 (10013-), 02 03 00 1E 00 02 A4 3E (40031-), 02 03 04 06 00 02 25 09 (41031-), 01 04 00 00 00 01 31 CA (30001), 01 04 03 E8 00 01 B1 BA (31001), 01 05 00 00 FF 00 8C 3A, 01 06 00 05 03 E8 99 75 (40006), 01 10 00 05 00 03 06 03 E8 00 64 00 32 56 BE (printed pp.16-27). Request and reply CRCs match calculation, except the last 31001 reply (01 04 02 01 4F), which repeats 38 32 from the previous example (calculated F9 54)."},{"ko":"통신 조건(인쇄 p.5): 9600 bps·데이터 8·정지 1 고정, 패리티 CoM 출하값 0 = 홀수(1 짝수·2 없음), 국번 STno 0~255(0 = 통신 정지), 프로토콜 PCoL = 1(Modbus). 함수 01·02·03·04·05·06·10h, 한 번에 03h·10h 60워드, 04h 37워드(인쇄 p.11).","en":"Communication (printed p.5): 9600 bps, 8 data bits and 1 stop bit fixed; parity CoM default 0 = odd (1 even, 2 none); station STno 0-255 (0 stops communication); protocol PCoL = 1 (Modbus). Functions 01, 02, 03, 04, 05, 06 and 10h; up to 60 words for 03h/10h and 37 for 04h (printed p.11)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"00001","type":"bit","name":{"ko":"FIX (설정값 비휘발 메모리 저장)","en":"FIX (save settings to non-volatile memory)"},"access":"rw","fc":[1,5],"description":{"ko":"1 = 저장 요청. 매뉴얼 예 01 05 00 00 FF 00 8C 3A. 저장에 약 5초 — 그동안 전원을 끄지 않는다","en":"1 = request. Manual example 01 05 00 00 FF 00 8C 3A. Saving takes about 5 s; do not power off meanwhile"},"ref":"인쇄 p.24 (PDF p.27), 인쇄 p.31 (PDF p.34)","source":0},{"table":"discrete-inputs","address":0,"manualAddress":"10001","type":"bit","name":{"ko":"경보 1 ON/OFF","en":"Alarm 1 ON/OFF"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":4,"manualAddress":"10005","type":"bit","name":{"ko":"경보 2 ON/OFF","en":"Alarm 2 ON/OFF"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":8,"manualAddress":"10009","type":"bit","name":{"ko":"경보 1 출력(비여자 경보 계산 결과)","en":"Alarm 1 output (de-energizing alarm result)"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":9,"manualAddress":"10010","type":"bit","name":{"ko":"경보 2 출력","en":"Alarm 2 output"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":10,"manualAddress":"10011","type":"bit","name":{"ko":"경보 3 출력","en":"Alarm 3 output"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":11,"manualAddress":"10012","type":"bit","name":{"ko":"HB(히터 단선) 경보 릴레이 출력","en":"HB (heater break) alarm relay output"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":12,"manualAddress":"10013","type":"bit","name":{"ko":"경보 1 ON/OFF (10001 과 같음)","en":"Alarm 1 ON/OFF (same as 10001)"},"access":"r","fc":[2],"description":{"ko":"매뉴얼 예: 1F 02 00 0C 00 02 3A 76 → 01h(경보 1 ON·경보 2 OFF)","en":"Manual example: 1F 02 00 0C 00 02 3A 76 → 01h (alarm 1 ON, alarm 2 OFF)"},"ref":"인쇄 p.18 (PDF p.21), 인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":13,"manualAddress":"10014","type":"bit","name":{"ko":"경보 2 ON/OFF","en":"Alarm 2 ON/OFF"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"discrete-inputs","address":14,"manualAddress":"10015","type":"bit","name":{"ko":"경보 3 ON/OFF","en":"Alarm 3 ON/OFF"},"access":"r","fc":[2],"ref":"인쇄 p.37 (PDF p.40)","source":0},{"table":"input-registers","address":0,"manualAddress":"30001","type":"s16","name":{"ko":"PV (내부 계산값, %FS)","en":"PV (internal value, %FS)"},"unit":"%","scale":0.01,"access":"r","fc":[4],"description":{"ko":"입력 범위에 대한 % (0.00~100.00 %FS). 매뉴얼 예 01 04 00 00 00 01 31 CA → 0346h = 8.38 %FS(0~400 ℃ 에서 33.5 ℃)","en":"% of input range (0.00-100.00 %FS). Manual example 01 04 00 00 00 01 31 CA → 0346h = 8.38 %FS (33.5 °C on a 0-400 °C range)"},"ref":"인쇄 p.22 (PDF p.25), 인쇄 p.36 (PDF p.39)","source":0},{"table":"input-registers","address":1000,"manualAddress":"31001","type":"s16","name":{"ko":"PV (공학 단위)","en":"PV (engineering units)"},"access":"r","fc":[4],"description":{"ko":"매뉴얼 예 01 04 03 E8 00 01 B1 BA → 014Fh = 335(소수점 1 → 33.5 ℃). 입력 이상이면 입력 범위의 105 %·−5 %","en":"Manual example 01 04 03 E8 00 01 B1 BA → 014Fh = 335 (1 decimal → 33.5 °C). On input error, 105 % or −5 % of the range"},"ref":"인쇄 p.23 (PDF p.26), 인쇄 p.42 (PDF p.45)","source":0},{"table":"input-registers","address":1001,"manualAddress":"31002","type":"s16","name":{"ko":"사용 중 SV","en":"SV in use"},"access":"r","fc":[4],"description":{"ko":"램프/소크·SV 전환 중에는 40003/41003(전면 SV)과 다를 수 있다 — 감시는 이 값으로","en":"May differ from 40003/41003 (front-panel SV) during ramp/soak or SV switching; monitor this one"},"ref":"인쇄 p.42 (PDF p.45)","source":0},{"table":"input-registers","address":1002,"manualAddress":"31003","type":"s16","name":{"ko":"사용 중 편차 DV","en":"Deviation DV in use"},"access":"r","fc":[4],"description":{"ko":"공학 단위(입력 범위로 스케일한 값), 소수점 없는 정수 — 소수점 자리는 41020(P-dP)","en":"Engineering units (scaled to the input range), integer without decimal point; decimal places from 41020 (P-dP)"},"ref":"인쇄 p.42 (PDF p.45)","source":0},{"table":"input-registers","address":1003,"manualAddress":"31004","type":"s16","name":{"ko":"MV (출력 1)","en":"MV (output 1)"},"unit":"%","scale":0.01,"access":"r","fc":[4],"range":{"min":-3,"max":103},"ref":"인쇄 p.42 (PDF p.45)","source":0},{"table":"input-registers","address":1004,"manualAddress":"31005","type":"s16","name":{"ko":"MV (출력 2)","en":"MV (output 2)"},"unit":"%","scale":0.01,"access":"r","fc":[4],"range":{"min":-3,"max":103},"ref":"인쇄 p.42 (PDF p.45)","source":0},{"table":"input-registers","address":1005,"manualAddress":"31006","type":"u16","name":{"ko":"국번","en":"Station number"},"access":"r","fc":[4],"ref":"인쇄 p.42 (PDF p.45)","source":0},{"table":"input-registers","address":1006,"manualAddress":"31007","type":"u16","name":{"ko":"경보 상태","en":"Alarm status"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"경보 1 출력","en":"Alarm 1 output"},{"bit":1,"ko":"경보 2 출력","en":"Alarm 2 output"},{"bit":2,"ko":"경보 3 출력","en":"Alarm 3 output"},{"bit":3,"ko":"HB 경보 릴레이 출력","en":"HB alarm relay output"},{"bit":4,"ko":"경보 1 ON","en":"Alarm 1 ON"},{"bit":5,"ko":"경보 2 ON","en":"Alarm 2 ON"},{"bit":6,"ko":"경보 3 ON","en":"Alarm 3 ON"},{"bit":7,"ko":"HB 경보 출력","en":"HB alarm output"}],"ref":"인쇄 p.42 (PDF p.45), 인쇄 p.44 (PDF p.47)","source":0},{"table":"input-registers","address":1007,"manualAddress":"31008","type":"u16","name":{"ko":"입력·본체 이상 상태","en":"Input/main unit abnormal status"},"access":"r","fc":[4],"bits":[{"bit":0,"ko":"입력 하한 단선","en":"Input lower open circuit"},{"bit":1,"ko":"입력 상한 단선","en":"Input upper open circuit"},{"bit":2,"ko":"입력 하한 밖(언더레인지)","en":"Input under-range"},{"bit":3,"ko":"입력 상한 밖(오버레인지)","en":"Input over-range"},{"bit":6,"ko":"설정 범위 이상","en":"Setting range error"},{"bit":7,"ko":"EEPROM 이상","en":"EEPROM error"}],"ref":"인쇄 p.42 (PDF p.45), 인쇄 p.44 (PDF p.47)","source":0},{"table":"input-registers","address":1008,"manualAddress":"31009","type":"u16","name":{"ko":"램프/소크 현재 위치","en":"Ramp/soak current position"},"access":"r","fc":[4],"range":{"min":0,"max":17},"ref":"인쇄 p.42 (PDF p.45), 인쇄 p.45 (PDF p.48)","source":0},{"table":"input-registers","address":1009,"manualAddress":"31010","type":"u16","name":{"ko":"히터 전류","en":"Heater current"},"unit":"A","scale":0.1,"access":"r","fc":[4],"range":{"min":0,"max":50},"ref":"인쇄 p.42 (PDF p.45)","source":0},{"table":"holding-registers","address":1002,"manualAddress":"41003","type":"s16","name":{"ko":"SV (전면 설정값)","en":"SV (front-panel set value)"},"access":"rw","fc":[3,6,16],"description":{"ko":"공학 단위(입력 범위로 스케일한 값), 소수점 없는 정수 — 소수점 자리는 41020(P-dP)","en":"Engineering units (scaled to the input range), integer without decimal point; decimal places from 41020 (P-dP)"},"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1003,"manualAddress":"41004","type":"u16","name":{"ko":"제어 RUN/대기","en":"Control RUN/standby"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"RUN(대기 해제)","en":"RUN (standby off)"},{"value":1,"ko":"대기","en":"Standby"}],"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1004,"manualAddress":"41005","type":"u16","name":{"ko":"오토 튜닝 명령","en":"Auto-tuning command"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"해제·정지","en":"Off / stop"},{"value":1,"ko":"표준형 AT","en":"Standard AT"},{"value":2,"ko":"낮은 PV 형 AT","en":"Low-PV type AT"}],"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1005,"manualAddress":"41006","type":"u16","name":{"ko":"P (비례대)","en":"P (proportional band)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":999.9},"description":{"ko":"매뉴얼 예: 01 06 00 05 03 E8 99 75(40006 에 100.0), 01 10 00 05 00 03 06 03 E8 00 64 00 32 56 BE(P·I·D 한 번에). 40006 과 같은 값","en":"Manual examples: 01 06 00 05 03 E8 99 75 (100.0 to 40006), 01 10 00 05 00 03 06 03 E8 00 64 00 32 56 BE (P, I, D at once). Same value as 40006"},"ref":"인쇄 p.25~27 (PDF p.28~30), 인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"I (적분 시간)","en":"I (integral time)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":3200},"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"D (미분 시간)","en":"D (derivative time)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":999.9},"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1015,"manualAddress":"41016","type":"u16","name":{"ko":"입력 종류 코드","en":"Input type code"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":16},"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1016,"manualAddress":"41017","type":"u16","name":{"ko":"온도 단위","en":"Temperature unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1017,"manualAddress":"41018","type":"s16","name":{"ko":"입력 스케일 하한 (P-SL)","en":"Input scale lower limit (P-SL)"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1018,"manualAddress":"41019","type":"s16","name":{"ko":"입력 스케일 상한 (P-SU)","en":"Input scale upper limit (P-SU)"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1019,"manualAddress":"41020","type":"u16","name":{"ko":"소수점 자리 (P-dP)","en":"Decimal point position (P-dP)"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":2},"description":{"ko":"통신으로 소수점을 바꾸면 P-SL·P-SU 도 함께 바꿔 써야 한다(예: 0~400 → 0.0~400.0 은 P-dP = 1, P-SL = 0, P-SU = 4000)","en":"When changing the decimal point over communication, rewrite P-SL and P-SU too (e.g. 0-400 → 0.0-400.0: P-dP = 1, P-SL = 0, P-SU = 4000)"},"ref":"인쇄 p.28 (PDF p.31)","source":0},{"table":"holding-registers","address":1030,"manualAddress":"41031","type":"s16","name":{"ko":"SV 하한 (SV-L)","en":"SV lower limit (SV-L)"},"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 예 02 03 04 06 00 02 25 09 → 0000h·0190h(SV-L 0, SV-H 400)","en":"Manual example 02 03 04 06 00 02 25 09 → 0000h, 0190h (SV-L 0, SV-H 400)"},"ref":"인쇄 p.21 (PDF p.24), 인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1031,"manualAddress":"41032","type":"s16","name":{"ko":"SV 상한 (SV-H)","en":"SV upper limit (SV-H)"},"access":"rw","fc":[3,6,16],"ref":"인쇄 p.38 (PDF p.41)","source":0},{"table":"holding-registers","address":1038,"manualAddress":"41039","type":"u16","name":{"ko":"히터 단선 경보값 (HB)","en":"Heater break alarm set value (HB)"},"unit":"A","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":50},"ref":"인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":1039,"manualAddress":"41040","type":"u16","name":{"ko":"설정 잠금 (LoC)","en":"Setting lock (LoC)"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":5},"description":{"ko":"잠긴 동안 쓰기 요청은 응답은 오지만 실행되지 않는다","en":"While locked, write requests get a normal reply but are not executed"},"ref":"인쇄 p.25 (PDF p.28), 인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":1040,"manualAddress":"41041","type":"u16","name":{"ko":"경보 1 종류 (ALM1)","en":"Alarm 1 type (ALM1)"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":34},"ref":"인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":1043,"manualAddress":"41044","type":"s16","name":{"ko":"경보 1 설정값 / 하한 (AL1·A1-L)","en":"Alarm 1 set value / lower limit (AL1, A1-L)"},"access":"rw","fc":[3,6,16],"description":{"ko":"공학 단위(입력 범위로 스케일한 값), 소수점 없는 정수 — 소수점 자리는 41020(P-dP)","en":"Engineering units (scaled to the input range), integer without decimal point; decimal places from 41020 (P-dP)"},"ref":"인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":1044,"manualAddress":"41045","type":"s16","name":{"ko":"경보 2 설정값 / 하한 (AL2·A2-L)","en":"Alarm 2 set value / lower limit (AL2, A2-L)"},"access":"rw","fc":[3,6,16],"ref":"인쇄 p.39 (PDF p.42)","source":0},{"table":"holding-registers","address":1081,"manualAddress":"41082","type":"u16","name":{"ko":"램프/소크 명령 (ProG)","en":"Ramp/soak command (ProG)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"oFF 정지","en":"oFF stop"},{"value":1,"ko":"rUn 시작","en":"rUn start"},{"value":2,"ko":"HLd 일시 정지","en":"HLd hold"},{"value":3,"ko":"End 끝남(읽기만)","en":"End finished (read only)"}],"ref":"인쇄 p.40 (PDF p.43)","source":0}],"notes":[{"ko":"입력 범위에 영향을 받는 값은 두 표로 읽을 수 있다: 내부 계산값(30001·40001~, 입력 범위의 0.00~100.00 %)과 공학 단위(번호 + 1000, 예 PV 31001). 이 파일은 공학 단위 표를 주로 적었다. 범위와 상관없는 값(PID 등)은 두 번호에서 같은 값이다(인쇄 p.28).","en":"Values that depend on the input range can be read from two tables: internal values (30001/40001-, 0.00-100.00 % of the input range) and engineering units (number + 1000, e.g. PV at 31001). This file lists mainly the engineering table. Range-independent values (PID etc.) read the same at both numbers (printed p.28)."},{"ko":"통신으로 쓴 파라미터는 자동으로 EEPROM 에 저장된다 — 쓰기 횟수 한도 100,000회, 주기적으로 쓰지 말 것(인쇄 p.15). 이 매뉴얼(TN512642d)은 PXR 구형(Micro Controller X) 통신 설명서다. 쪽 번호는 인쇄 쪽(PDF = 인쇄 + 3).","en":"Parameters written over communication are saved to EEPROM automatically: 100,000-write limit, avoid cyclic writes (printed p.15). This manual (TN512642d) covers the earlier PXR (Micro Controller X). Page numbers are printed pages (PDF = printed + 3)."}],"sources":[{"title":"Micro Controller X Communication Functions (RS-485 MODBUS) Type: PXR — Instruction Manual","publisher":"Fuji Electric","edition":{"ko":"INP-TN512642d-E","en":"INP-TN512642d-E"},"url":"https://americas.fujielectric.com/files/prod_selector_v/Micro%20Controller%20X%20Communication%20Functions%20%28MODBUS%29%20Model%20PXR%20%28TN512642d-E%29.pdf","pages":{"ko":"인쇄 p.5 통신 설정, p.8~27 프로토콜·예, p.28~46 데이터 형식·주소표 (PDF p.8, 11~30, 31~49)","en":"printed p.5 settings, pp.8-27 protocol and examples, pp.28-46 data format and address maps (PDF p.8, 11-30, 31-49)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"hanyoung-nux/lc","manufacturer":{"ko":"한영넉스","en":"Hanyoung Nux"},"model":"LC Series","models":["LC1","LC3","LC4","LC6","LC7"],"kind":"other","title":{"ko":"한영넉스 LC 시리즈 LCD 카운터/타이머","en":"Hanyoung Nux LC series LCD counter/timer"},"summary":{"ko":"RS485 Modbus RTU(형번 보조출력 자리 'C' 통신형). 코일·입력 상태·입력 레지스터·홀딩 레지스터를 모두 쓴다. 쓰기 금지(CWP)가 초기값 ON.","en":"RS485 Modbus RTU (models with auxiliary-output code 'C'). Uses coils, discrete inputs, input and holding registers. Write inhibit (CWP) is ON by default."},"protocols":["rtu"],"comm":{"addressing":"plc","baud":9600,"bauds":[2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,127],"notes":[{"ko":"매뉴얼은 «40001 (0000)» 처럼 PLC 번호와 괄호 속 16진 통신 주소를 함께 적는다. 통신선 주소 = 괄호 값. 근거: p.32(PDF 30) FC01 예가 시작 주소 0x0000 으로 코일 00001~00005 를 읽음, p.35~41(PDF 33~39) 맵.","en":"The manual writes '40001 (0000)': PLC number plus hex wire address in brackets. Wire address = bracket value. Evidence: FC01 example p.32 (PDF 30) reads coils 00001-00005 from 0x0000; map p.35-41 (PDF 33-39)."},{"ko":"초기값: 국번 1, 9600 bps, 패리티 없음, 응답 대기 20 ms, 통신 쓰기 금지 ON (p.31, PDF 29). 스톱 1 비트 고정, 데이터 8 비트 (p.12, PDF 10).","en":"Defaults: station 1, 9600 bps, no parity, response wait 20 ms, communication write inhibit ON (p.31, PDF 29). Stop bit fixed 1, data 8 bits (p.12, PDF 10)."},{"ko":"통신 쓰기 금지(CWP)가 ON 이면 쓰기 요청에 예외 응답을 돌려준다 — 쓰려면 앞판에서 CWP 를 OFF 로 바꾼다(p.31·p.34).","en":"With write inhibit (CWP) ON, writes get an exception reply — turn CWP OFF on the front panel first (p.31, p.34)."},{"ko":"지원 함수 코드: 01·02·03·04·05·06·16 (p.30). 응답 데이터 개수 표기: FC03 «n = 1~16», FC04 «n = 1~13», FC16 «n = 1~16» (p.33~34).","en":"Supported FCs: 01, 02, 03, 04, 05, 06, 16 (p.30). Data count shown as FC03 'n = 1-16', FC04 'n = 1-13', FC16 'n = 1-16' (p.33-34)."},{"ko":"응답 대기 최소값은 속도마다 다르다: 2400 bps 16 ms, 4800 bps 8 ms, 9600 이상 5 ms (p.31).","en":"Minimum response wait depends on speed: 2400 bps 16 ms, 4800 bps 8 ms, 9600+ 5 ms (p.31)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"00001 (0000)","type":"bit","name":{"ko":"리셋 입력","en":"Reset input"},"access":"rw","fc":[1,5],"description":{"ko":"FC05 로 1 을 보낼 때는 FF00 으로 보낸다.","en":"When writing 1 with FC05, send FF00."},"ref":"p.35 (PDF 33) 표 1 Func 01H/05H"},{"table":"coils","address":1,"manualAddress":"00002 (0001)","type":"bit","name":{"ko":"배치 리셋 입력","en":"Batch reset input"},"access":"rw","fc":[1,5],"description":{"ko":"FC05 로 1 을 보낼 때는 FF00.","en":"Send FF00 for 1 with FC05."},"ref":"p.35 (PDF 33) 표 1"},{"table":"coils","address":2,"manualAddress":"00003 (0002)","type":"bit","name":{"ko":"OUT1 출력","en":"OUT1 output"},"access":"r","fc":[1],"ref":"p.35 (PDF 33) 표 1"},{"table":"coils","address":3,"manualAddress":"00004 (0003)","type":"bit","name":{"ko":"OUT2 출력","en":"OUT2 output"},"access":"r","fc":[1],"ref":"p.35 (PDF 33) 표 1"},{"table":"coils","address":4,"manualAddress":"00005 (0004)","type":"bit","name":{"ko":"배치 출력","en":"Batch output"},"access":"r","fc":[1],"ref":"p.35 (PDF 33) 표 1"},{"table":"discrete-inputs","address":0,"manualAddress":"10001 (0000)","type":"bit","name":{"ko":"리셋 단자 입력","en":"Reset terminal input"},"access":"r","fc":[2],"ref":"p.35 (PDF 33) 표 2 Func 02H"},{"table":"discrete-inputs","address":1,"manualAddress":"10002 (0001)","type":"bit","name":{"ko":"배치 리셋 단자 입력","en":"Batch reset terminal input"},"access":"r","fc":[2],"ref":"p.35 (PDF 33) 표 2"},{"table":"discrete-inputs","address":2,"manualAddress":"10003 (0002)","type":"bit","name":{"ko":"CP1 입력","en":"CP1 input"},"access":"r","fc":[2],"ref":"p.35 (PDF 33) 표 2"},{"table":"discrete-inputs","address":3,"manualAddress":"10004 (0003)","type":"bit","name":{"ko":"CP2 입력","en":"CP2 input"},"access":"r","fc":[2],"ref":"p.35 (PDF 33) 표 2"},{"table":"input-registers","address":103,"manualAddress":"30104 (0067)","type":"u16","name":{"ko":"펌웨어 버전","en":"Firmware version"},"access":"r","fc":[4],"ref":"p.36 (PDF 34) 표 3 Product Information"},{"table":"input-registers","address":1000,"manualAddress":"31001 (03E8)","type":"u16","name":{"ko":"LED 표시 상태","en":"LED display status"},"access":"r","fc":[4],"bits":[{"bit":3,"ko":"CWP LED","en":"CWP LED"},{"bit":4,"ko":"RST LED","en":"RST LED"},{"bit":5,"ko":"INH LED","en":"INH LED"},{"bit":6,"ko":"STA LED","en":"STA LED"},{"bit":7,"ko":"BATCH OUT LED","en":"BATCH OUT LED"},{"bit":8,"ko":"OUT2 LED","en":"OUT2 LED"},{"bit":9,"ko":"OUT1 LED","en":"OUT1 LED"},{"bit":10,"ko":"BATCH LED","en":"BATCH LED"},{"bit":11,"ko":"LOCK LED","en":"LOCK LED"},{"bit":12,"ko":"SET1 LED","en":"SET1 LED"},{"bit":13,"ko":"SET2 LED","en":"SET2 LED"},{"bit":14,"ko":"TIM LED","en":"TIM LED"}],"description":{"ko":"비트 0 = 꺼짐, 1 = 켜짐.","en":"Bit 0 = off, 1 = on."},"ref":"p.36 (PDF 34) 표 3 Product Monitoring"},{"table":"input-registers","address":1005,"manualAddress":"31006 (03ED)","type":"u16","name":{"ko":"소수점 위치","en":"Decimal point"},"access":"r","fc":[4],"description":{"ko":"카운터: 0·1 = 소수점 없음, 2 = 소수 2자리, 3 = 3자리, 4 = 4자리(6자리 형만), 5 = 5자리(6자리 형만). 타이머: 시간 범위 코드 0 u.01s, 1 u.1s, 2 u1s, 3 u1m, 4 u1h, 5 d.01s, 6 d.1s, 7 d1s, 8 d1m, 9 d1h.","en":"Counter: 0/1 = none, 2 = 2 decimals, 3 = 3, 4 = 4 (6-digit only), 5 = 5 (6-digit only). Timer: time-range code 0 u.01s, 1 u.1s, 2 u1s, 3 u1m, 4 u1h, 5 d.01s, 6 d.1s, 7 d1s, 8 d1m, 9 d1h."},"ref":"p.36 (PDF 34) 표 3"},{"table":"input-registers","address":1012,"manualAddress":"31013 (03F4)","type":"u16","name":{"ko":"입력 논리","en":"Input logic"},"access":"r","fc":[4],"values":[{"value":0,"ko":"NPN","en":"NPN"},{"value":1,"ko":"PNP","en":"PNP"}],"ref":"p.37 (PDF 35) 표 3"},{"table":"holding-registers","address":50,"manualAddress":"40051 (0032)","type":"u16","name":{"ko":"동작 모드","en":"Operation mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"카운터","en":"Counter"},{"value":1,"ko":"배치 카운터","en":"Batch counter"},{"value":2,"ko":"타이머","en":"Timer"},{"value":3,"ko":"트윈 타이머","en":"Twin timer"},{"value":4,"ko":"배치 타이머","en":"Batch timer"}],"ref":"p.38 (PDF 36) 표 4 Counter Setting"},{"table":"holding-registers","address":51,"manualAddress":"40052 (0033)","type":"u16","name":{"ko":"카운터 입력 모드","en":"Counter input mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"U-A","en":"U-A"},{"value":1,"ko":"U-B","en":"U-B"},{"value":2,"ko":"U-AB","en":"U-AB"},{"value":3,"ko":"D-A","en":"D-A"},{"value":4,"ko":"D-B","en":"D-B"},{"value":5,"ko":"D-AB","en":"D-AB"},{"value":6,"ko":"UD-A","en":"UD-A"},{"value":7,"ko":"UD-B","en":"UD-B"},{"value":8,"ko":"UD-C","en":"UD-C"},{"value":9,"ko":"UD-D","en":"UD-D"},{"value":10,"ko":"UD-E","en":"UD-E"},{"value":11,"ko":"UD-F","en":"UD-F"}],"ref":"p.38 (PDF 36) 표 4 Counter Setting"},{"table":"holding-registers","address":53,"manualAddress":"40054 (0035)","type":"u16","name":{"ko":"카운터 출력 모드","en":"Counter output mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"N","en":"N"},{"value":1,"ko":"F","en":"F"},{"value":2,"ko":"C","en":"C"},{"value":3,"ko":"R","en":"R"},{"value":4,"ko":"K","en":"K"},{"value":5,"ko":"P","en":"P"},{"value":6,"ko":"Q","en":"Q"},{"value":7,"ko":"A","en":"A"}],"ref":"p.38 (PDF 36) 표 4 Counter Setting"},{"table":"holding-registers","address":54,"manualAddress":"40055 (0036)","type":"u16","name":{"ko":"최대 계수 속도","en":"Max counting speed"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1 cps","en":"1 cps"},{"value":1,"ko":"30 cps","en":"30 cps"},{"value":2,"ko":"1 kcps","en":"1 kcps"},{"value":3,"ko":"10 kcps","en":"10 kcps"}],"ref":"p.39 (PDF 37) 표 4 Counter Setting"},{"table":"holding-registers","address":56,"manualAddress":"40057 (0038)","type":"u16","name":{"ko":"OUT1 출력 시간","en":"OUT1 output time"},"unit":"s","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":99.99},"description":{"ko":"0 = 유지(Hold).","en":"0 = hold."},"ref":"p.39 (PDF 37) 표 4 Counter Setting"},{"table":"holding-registers","address":57,"manualAddress":"40058 (0039)","type":"u16","name":{"ko":"카운터 소수점","en":"Counter decimal point"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":5},"description":{"ko":"0 = 없음, 1~5 = 소수 1~5자리(4·5 는 6자리 형만).","en":"0 = none, 1-5 = 1-5 decimals (4 and 5 on 6-digit models only)."},"ref":"p.39 (PDF 37) 표 4 Counter Setting"},{"table":"holding-registers","address":64,"manualAddress":"40065 (0040)","type":"u16","name":{"ko":"카운터 백업","en":"Counter backup"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"지움","en":"Clear"},{"value":1,"ko":"저장","en":"Save"}],"ref":"p.39 (PDF 37) 표 4 Counter Setting"},{"table":"holding-registers","address":65,"manualAddress":"40066 (0041)","type":"u16","name":{"ko":"카운터 키 잠금","en":"Counter lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"Lock-off","en":"Lock-off"},{"value":1,"ko":"Lock-on","en":"Lock-on"},{"value":2,"ko":"Lock-set","en":"Lock-set"},{"value":3,"ko":"Lock-reset","en":"Lock-reset"}],"ref":"p.39 (PDF 37) 표 4 Counter Setting"},{"table":"holding-registers","address":101,"manualAddress":"40102 (0065)","type":"u16","name":{"ko":"타이머 시간 범위","en":"Timer range"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"u.01s","en":"u.01s"},{"value":1,"ko":"u.1s","en":"u.1s"},{"value":2,"ko":"u1s","en":"u1s"},{"value":3,"ko":"u1m","en":"u1m"},{"value":4,"ko":"u1h","en":"u1h"},{"value":5,"ko":"d.01s","en":"d.01s"},{"value":6,"ko":"d.1s","en":"d.1s"},{"value":7,"ko":"d1s","en":"d1s"},{"value":8,"ko":"d1m","en":"d1m"},{"value":9,"ko":"d1h","en":"d1h"}],"ref":"p.41 (PDF 39) 표 4 Timer Setting"},{"table":"holding-registers","address":102,"manualAddress":"40103 (0066)","type":"u16","name":{"ko":"타이머 진법","en":"Timer scale"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"10진","en":"Decimal"},{"value":1,"ko":"60진","en":"Sexagesimal"}],"ref":"p.41 (PDF 39) 표 4 Timer Setting"},{"table":"holding-registers","address":103,"manualAddress":"40104 (0067)","type":"u16","name":{"ko":"타이머 출력 모드","en":"Timer output mode"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":16},"description":{"ko":"타이머: 0 pond, 1 sond, 2 sofd, 3 sint, 4 sadd, 5 s.ond, 6 s.on1, 7 s.int, 8 s.flk, 9 s.fr, 10 s.fp, 11 s.fq. 트윈 타이머: 12 tw-pond, 13 tw-pofd, 14 tw-poft, 15 tw-s.ond, 16 tw-s.ofd (매뉴얼은 A~F·10 을 16진으로 적음).","en":"Timer: 0 pond, 1 sond, 2 sofd, 3 sint, 4 sadd, 5 s.ond, 6 s.on1, 7 s.int, 8 s.flk, 9 s.fr, 10 s.fp, 11 s.fq. Twin timer: 12 tw-pond, 13 tw-pofd, 14 tw-poft, 15 tw-s.ond, 16 tw-s.ofd (manual writes A-F and 10 in hex)."},"ref":"p.40 (PDF 38) 표 4 Timer Setting"},{"table":"holding-registers","address":106,"manualAddress":"40107 (006A)","type":"u16","name":{"ko":"타이머 OUT 출력 시간","en":"Timer OUT output time"},"unit":"s","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":99.99},"description":{"ko":"0 = 유지(Hold).","en":"0 = hold."},"ref":"p.40 (PDF 38) 표 4 Timer Setting"},{"table":"holding-registers","address":150,"manualAddress":"40151 (0096)","type":"u16","name":{"ko":"국번","en":"Station address"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":127},"description":{"ko":"매뉴얼 표기 1~7F(16진).","en":"Manual shows 1-7F (hex)."},"ref":"p.40 (PDF 38) 표 4 Communication Setting"},{"table":"holding-registers","address":151,"manualAddress":"40152 (0097)","type":"u16","name":{"ko":"통신 속도","en":"Baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400","en":"2400"},{"value":1,"ko":"4800","en":"4800"},{"value":2,"ko":"9600","en":"9600"},{"value":3,"ko":"19200","en":"19200"},{"value":4,"ko":"38400","en":"38400"}],"ref":"p.40 (PDF 38) 표 4 Communication Setting"},{"table":"holding-registers","address":152,"manualAddress":"40153 (0098)","type":"u16","name":{"ko":"패리티","en":"Parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수","en":"Even"}],"ref":"p.40 (PDF 38) 표 4 Communication Setting"},{"table":"holding-registers","address":154,"manualAddress":"40155 (009A)","type":"u16","name":{"ko":"응답 대기 시간","en":"Response wait time"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"p.40 (PDF 38) 표 4 Communication Setting"},{"table":"holding-registers","address":155,"manualAddress":"40156 (009B)","type":"u16","name":{"ko":"통신 쓰기 금지","en":"Communication write inhibit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"끔","en":"Off"},{"value":1,"ko":"켬","en":"On"}],"description":{"ko":"켜져 있으면 통신 쓰기가 거부된다(초기값 ON, p.31).","en":"When on, communication writes are rejected (default ON, p.31)."},"ref":"p.40 (PDF 38) 표 4 Communication Setting"}],"notes":[{"ko":"32비트 값(배치 PV·PV·SV1·SV2·배치 SV)은 연속 레지스터 2개를 쓰지만 매뉴얼에 상·하위 워드 순서가 적혀 있지 않다. order 를 넣지 않았으니 실제 기기로 확인하고 쓴다.","en":"32-bit values (batch PV, PV, SV1, SV2, batch SV) span two registers, but the manual does not state word order. No order given — verify on a device."},{"ko":"통신 기능은 형번의 보조 출력 자리가 'C'(RS485 MODBUS-RTU)인 모델만 있다(선택 가이드 p.10~11).","en":"Communication is only on models whose auxiliary-output code is 'C' (selection guide p.10-11)."},{"ko":"32비트 값(31002 배치 현재값, 31004 현재값(PV), 40001 설정값 2 (SV2), 40003 설정값 1 (SV1), 40005 배치 설정값)은 매뉴얼에 워드 순서가 없어 넣지 않았다 — 실기로 순서를 확인한 뒤 쓴다.","en":"32-bit values (31002 Batch PV, 31004 Present value (PV), 40001 Set value 2 (SV2), 40003 Set value 1 (SV1), 40005 Batch SV) are left out because the manual does not state the word order — confirm it on a real unit first."}],"sources":[{"title":"LC SERIES USER MANUAL","publisher":"HANYOUNG NUX","edition":{"ko":"MD0901E260602_U (파일명 LC_user_en_260720)","en":"MD0901E260602_U (file name LC_user_en_260720)"},"url":"https://www.hanyoungnux.com/data/main_view.php?down=1699(LC_user_en_260720).pdf&file_name=LC.pdf","pages":{"ko":"p.12 사양, p.30~41 통신 (PDF 쪽 = 인쇄 쪽 - 2)","en":"p.12 specifications, pp.30-41 communication (PDF page = printed page - 2)"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"hanyoung-nux/lm","manufacturer":{"ko":"한영넉스","en":"Hanyoung Nux"},"model":"LM Series","models":["LM3-4DV-3RC-A","LM3-4DA-3RC-A","LM3-4AV-3RC-A","LM3-4AA-3RC-A","LM3-4DV-3NC-A","LM3-4DA-3NC-A","LM3-4AV-3NC-A","LM3-4AA-3NC-A","LM3-4DV-3PC-A","LM3-4DA-3PC-A","LM3-4AV-3PC-A","LM3-4AA-3PC-A","LM6-4DV-RC-A","LM6-4DA-RC-A","LM6-4AV-RC-A","LM6-4AA-RC-A"],"kind":"panel-meter","title":{"ko":"한영넉스 LM 시리즈 LCD 멀티 패널미터 (RS485 모델)","en":"Hanyoung Nux LM series LCD multi panel meter (RS485 models)"},"summary":{"ko":"직류·교류 전압/전류 4자리 패널미터. 옵션 출력 자리 'C'(RS485) 모델만 Modbus RTU. 코일(비교 출력 상태), 입력 접점(HOLD), 입력 레지스터(제품 정보·PV·MAX/MIN·램프 상태), 보유 레지스터(비교값·기능·출력·통신 설정)를 담았다.","en":"4-digit DC/AC voltage/current panel meter. Only models with option code 'C' (RS485) speak Modbus RTU. Covers coils (comparison outputs), a discrete input (HOLD), input registers (product info, PV, MAX/MIN, lamp status) and holding registers (comparison values, function, output and comm settings)."},"protocols":["rtu"],"comm":{"addressing":"plc","baud":9600,"bauds":[2400,4800,9600,19200,38400],"parity":"none","stopBits":1,"unit":1,"unitRange":[1,127],"notes":[{"ko":"근거: 매뉴얼은 «40001 (0000)» 꼴 — PLC 번호와 괄호 속 16진 통신 주소. 인쇄 p.32 (PDF p.31) FC01 예 «01 01 00 00 00 03 7C 0B» 는 코일 00001~00003(0000~0002, L/GO/H-OUT)을, FC02 예 «01 02 00 00 00 01 B9 CA» 는 10001(0000, HOLD)을 읽는다. 인쇄 p.34 (PDF p.33) 예외 예 «01 03 00 95 00 07» 은 40151(0096) 바로 앞 빈 번지라 예외 02. 통신선 주소 = 괄호 값 = PLC 번호 − 00001/10001/30001/40001. 예의 CRC 는 모두 검산해 맞다.","en":"Evidence: the manual writes '40001 (0000)' = PLC number plus hex wire address. Printed p.32 (PDF p.31): FC01 example '01 01 00 00 00 03 7C 0B' reads coils 00001-00003 (0000-0002, L/GO/H-OUT); FC02 example '01 02 00 00 00 01 B9 CA' reads 10001 (0000, HOLD). Printed p.34 (PDF p.33): exception example '01 03 00 95 00 07' starts at the unused address just before 40151 (0096) and gets exception 02. Wire address = bracket value = PLC number minus 00001/10001/30001/40001. All example CRCs verified."},{"ko":"초기값: 국번 001, 9600 bps, 패리티 NONE, 응답 대기 20 ms, 통신 쓰기 금지 ON (인쇄 p.27, PDF p.26). 정지 비트는 1 고정(40154 «0 (1-STOP)» 고정, 인쇄 p.39). 데이터 비트는 매뉴얼에 적혀 있지 않다.","en":"Defaults: station 001, 9600 bps, parity NONE, response wait 20 ms, comm write protect ON (printed p.27, PDF p.26). Stop bit fixed at 1 (40154 '0 (1-STOP)' fixed, printed p.39). Data bits are not stated in the manual."},{"ko":"통신 쓰기 금지(CWP)가 ON 이면 쓰기 요청에 예외 04 를 돌려준다(인쇄 p.34) — 쓰려면 먼저 CWP 를 OFF 로.","en":"With write protect (CWP) ON, write requests get exception 04 (printed p.34) — set CWP OFF first."}]},"registers":[{"table":"coils","address":0,"manualAddress":"00001 (0000)","type":"bit","name":{"ko":"LOW-OUT 출력 상태","en":"LOW-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"coils","address":1,"manualAddress":"00002 (0001)","type":"bit","name":{"ko":"GO-OUT 출력 상태","en":"GO-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"coils","address":2,"manualAddress":"00003 (0002)","type":"bit","name":{"ko":"HIGH-OUT 출력 상태","en":"HIGH-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"discrete-inputs","address":0,"manualAddress":"10001 (0000)","type":"bit","name":{"ko":"HOLD 입력 상태","en":"HOLD input state"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":100,"manualAddress":"30101 (0064)","type":"u16","name":{"ko":"제품 번호 (하위 워드)","en":"Product number (low word)"},"access":"r","fc":[4],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":101,"manualAddress":"30102 (0065)","type":"u16","name":{"ko":"제품 번호 (상위 워드)","en":"Product number (high word)"},"access":"r","fc":[4],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":102,"manualAddress":"30103 (0066)","type":"u16","name":{"ko":"하드웨어 버전","en":"Hardware version"},"access":"r","fc":[4],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":103,"manualAddress":"30104 (0067)","type":"u16","name":{"ko":"펌웨어 버전","en":"Firmware version"},"access":"r","fc":[4],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":104,"manualAddress":"30105 (0068)","type":"string","name":{"ko":"모델명","en":"Model name"},"access":"r","fc":[4],"len":2,"description":{"ko":"\"LM\" 두 글자.","en":"Two characters \"LM\"."},"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":105,"manualAddress":"30106 (0069)","type":"string","name":{"ko":"계측 입력 사양","en":"Measuring input type"},"access":"r","fc":[4],"len":2,"description":{"ko":"\"AV\" 교류 전압, \"AA\" 교류 전류, \"DV\" 직류 전압, \"DA\" 직류 전류.","en":"\"AV\" AC voltage, \"AA\" AC current, \"DV\" DC voltage, \"DA\" DC current."},"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":106,"manualAddress":"30107 (006A)","type":"u16","name":{"ko":"옵션 출력 사양","en":"Option output type"},"access":"r","fc":[4],"values":[{"value":0,"ko":"N (지시 전용)","en":"N (indicator only)"},{"value":3,"ko":"RC (1단 출력)","en":"RC (1-stage output)"},{"value":5,"ko":"3RC/3NC/3PC (3단 출력)","en":"3RC/3NC/3PC (3-stage output)"}],"bits":[{"bit":0,"ko":"0 지시 전용 / 1 출력 있음","en":"0 indicator only / 1 with output"},{"bit":1,"ko":"1단","en":"1-stage"},{"bit":2,"ko":"3단","en":"3-stage"}],"ref":"인쇄 p.35 (PDF p.34)","source":0},{"table":"input-registers","address":1000,"manualAddress":"31001 (03E8)","type":"u16","name":{"ko":"동작 램프 표시 상태","en":"Active lamp status"},"access":"r","fc":[4],"bits":[{"bit":1,"ko":"L-OUT 램프","en":"L-OUT lamp"},{"bit":2,"ko":"GO-OUT 램프","en":"GO-OUT lamp"},{"bit":3,"ko":"H-OUT 램프","en":"H-OUT lamp"},{"bit":4,"ko":"DC 램프","en":"DC lamp"},{"bit":5,"ko":"AC 램프","en":"AC lamp"},{"bit":6,"ko":"L-SET 램프","en":"L-SET lamp"},{"bit":7,"ko":"H-SET 램프","en":"H-SET lamp"},{"bit":8,"ko":"COM 램프","en":"COM lamp"},{"bit":9,"ko":"RMS 램프","en":"RMS lamp"},{"bit":10,"ko":"CWP 램프","en":"CWP lamp"},{"bit":11,"ko":"LOCK 램프","en":"LOCK lamp"},{"bit":12,"ko":"ZERO 램프","en":"ZERO lamp"},{"bit":13,"ko":"HOLD 램프","en":"HOLD lamp"},{"bit":14,"ko":"MIN 램프","en":"MIN lamp"},{"bit":15,"ko":"MAX 램프","en":"MAX lamp"}],"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1001,"manualAddress":"31002 (03E9)","type":"u16","name":{"ko":"단위 램프 표시 상태","en":"Unit lamp status"},"access":"r","fc":[4],"bits":[{"bit":1,"ko":"V 램프","en":"V lamp"},{"bit":2,"ko":"mV 램프","en":"mV lamp"},{"bit":3,"ko":"A 램프","en":"A lamp"},{"bit":4,"ko":"mA 램프","en":"mA lamp"},{"bit":5,"ko":"W 램프","en":"W lamp"},{"bit":6,"ko":"KW 램프","en":"KW lamp"},{"bit":7,"ko":"Hz 램프","en":"Hz lamp"}],"description":{"ko":"mV 는 bit1·bit2, mA 는 bit3·bit4, KW 는 bit5·bit6 이 함께 1.","en":"mV sets bit1+bit2, mA sets bit3+bit4, KW sets bit5+bit6."},"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1002,"manualAddress":"31003 (03EA)","type":"s16","name":{"ko":"측정값 (PV)","en":"Process value (PV)"},"access":"r","fc":[4],"description":{"ko":"원시 -9999~9999. 소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4). OVER/S.OVR 이면 9999, -OVER/-S.OVR 이면 -9999.","en":"Raw -9999..9999. Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4). 9999 on OVER/S.OVR, -9999 on -OVER/-S.OVR."},"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1003,"manualAddress":"31004 (03EB)","type":"s16","name":{"ko":"최대값 (MAX)","en":"Maximum value (MAX)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1004,"manualAddress":"31005 (03EC)","type":"s16","name":{"ko":"최소값 (MIN)","en":"Minimum value (MIN)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1005,"manualAddress":"31006 (03ED)","type":"s16","name":{"ko":"하한 비교값 (LSV)","en":"Low comparison value (LSV)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1006,"manualAddress":"31007 (03EE)","type":"s16","name":{"ko":"상한 비교값 (HSV)","en":"High comparison value (HSV)"},"access":"r","fc":[4],"description":{"ko":"소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1007,"manualAddress":"31008 (03EF)","type":"u16","name":{"ko":"소수점 위치 (DOT)","en":"Decimal point (DOT)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0000","en":"0000"},{"value":1,"ko":"000.0","en":"000.0"},{"value":2,"ko":"00.00","en":"00.00"},{"value":3,"ko":"0.000","en":"0.000"}],"ref":"인쇄 p.36 (PDF p.35)","source":0},{"table":"input-registers","address":1008,"manualAddress":"31009 (03F0)","type":"u16","name":{"ko":"입력 레인지 (RANG)","en":"Input range (RANG)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"AV 500V · AA 5A · DV 500V · DA 5A","en":"AV 500V, AA 5A, DV 500V, DA 5A"},{"value":1,"ko":"AV 250V · AA 2A · DV 100V · DA 2A","en":"AV 250V, AA 2A, DV 100V, DA 2A"},{"value":2,"ko":"AV 110V · AA 500mA · DV 50V · DA 500mA","en":"AV 110V, AA 500mA, DV 50V, DA 500mA"},{"value":3,"ko":"AV 50V · AA 200mA · DV 10V · DA 200mA","en":"AV 50V, AA 200mA, DV 10V, DA 200mA"},{"value":4,"ko":"AV 20V · AA 50mA · DV 5V · DA 50mA","en":"AV 20V, AA 50mA, DV 5V, DA 50mA"},{"value":5,"ko":"AV 10V · AA 20mA · DV 1V · DA 4-20mA","en":"AV 10V, AA 20mA, DV 1V, DA 4-20mA"},{"value":6,"ko":"AV 2V · DV 200mV · DA 5mA","en":"AV 2V, DV 200mV, DA 5mA"},{"value":7,"ko":"AV 1V · DV 50mV · DA 2mA","en":"AV 1V, DV 50mV, DA 2mA"}],"description":{"ko":"입력 레인지는 모델별로 다르다 — AV 0~7, AA 0~5, DV 0~7, DA 0~7.","en":"Range depends on model: AV 0-7, AA 0-5, DV 0-7, DA 0-7."},"ref":"인쇄 p.37 (PDF p.36)","source":0},{"table":"input-registers","address":1009,"manualAddress":"31010 (03F1)","type":"u16","name":{"ko":"출력 모드 (O-MD)","en":"Output mode (O-MD)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"출력 OFF","en":"Output OFF"},{"value":1,"ko":"LO 출력 모드","en":"LO output mode"},{"value":2,"ko":"HI 출력 모드","en":"HI output mode"},{"value":3,"ko":"LH 출력 모드","en":"LH output mode"},{"value":4,"ko":"LL 출력 모드","en":"LL output mode"},{"value":5,"ko":"HH 출력 모드","en":"HH output mode"},{"value":6,"ko":"LD 출력 모드","en":"LD output mode"}],"description":{"ko":"출력 있는 모델만.","en":"Output models only."},"ref":"인쇄 p.37 (PDF p.36)","source":0},{"table":"holding-registers","address":0,"manualAddress":"40001 (0000)","type":"s16","name":{"ko":"하한 비교값 (LSV)","en":"Low comparison value (LSV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"LSV < HSV 로 설정. 출력 모드 LD/LO/HH/LL/LH 에서 설정. 소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Set LSV < HSV. Used in LD/LO/HH/LL/LH output modes. Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.37 (PDF p.36)","source":0},{"table":"holding-registers","address":1,"manualAddress":"40002 (0001)","type":"s16","name":{"ko":"상한 비교값 (HSV)","en":"High comparison value (HSV)"},"access":"rw","fc":[3,6,16],"description":{"ko":"HSV > LSV 로 설정. 출력 모드 HI/HH/LL/LH 에서 설정. 소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Set HSV > LSV. Used in HI/HH/LL/LH output modes. Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.37 (PDF p.36)","source":0},{"table":"holding-registers","address":50,"manualAddress":"40051 (0032)","type":"u16","name":{"ko":"측정 모드 (FUNC)","en":"Measuring mode (FUNC)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"기본 측정 (NOR)","en":"Normal (NOR)"},{"value":1,"ko":"스케일 측정 (SCAL)","en":"Scaled (SCAL)"},{"value":2,"ko":"주파수 측정 (FREQ)","en":"Frequency (FREQ)"}],"description":{"ko":"FREQ 는 AV/AA 모델만.","en":"FREQ on AV/AA models only."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":51,"manualAddress":"40052 (0033)","type":"u16","name":{"ko":"입력 레인지 (RANG)","en":"Input range (RANG)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"AV 500V · AA 5A · DV 500V · DA 5A","en":"AV 500V, AA 5A, DV 500V, DA 5A"},{"value":1,"ko":"AV 250V · AA 2A · DV 100V · DA 2A","en":"AV 250V, AA 2A, DV 100V, DA 2A"},{"value":2,"ko":"AV 110V · AA 500mA · DV 50V · DA 500mA","en":"AV 110V, AA 500mA, DV 50V, DA 500mA"},{"value":3,"ko":"AV 50V · AA 200mA · DV 10V · DA 200mA","en":"AV 50V, AA 200mA, DV 10V, DA 200mA"},{"value":4,"ko":"AV 20V · AA 50mA · DV 5V · DA 50mA","en":"AV 20V, AA 50mA, DV 5V, DA 50mA"},{"value":5,"ko":"AV 10V · AA 20mA · DV 1V · DA 4-20mA","en":"AV 10V, AA 20mA, DV 1V, DA 4-20mA"},{"value":6,"ko":"AV 2V · DV 200mV · DA 5mA","en":"AV 2V, DV 200mV, DA 5mA"},{"value":7,"ko":"AV 1V · DV 50mV · DA 2mA","en":"AV 1V, DV 50mV, DA 2mA"}],"description":{"ko":"입력 레인지는 모델별로 다르다 — AV 0~7, AA 0~5, DV 0~7, DA 0~7.","en":"Range depends on model: AV 0-7, AA 0-5, DV 0-7, DA 0-7."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":53,"manualAddress":"40054 (0035)","type":"s16","name":{"ko":"영점 편차 보정값 (ZERO)","en":"Zero offset correction (ZERO)"},"access":"rw","fc":[3,6,16],"range":{"min":-99,"max":99},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":55,"manualAddress":"40056 (0037)","type":"u16","name":{"ko":"AC 측정 방식 (AC.TY)","en":"AC measuring method (AC.TY)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"평균값 측정","en":"Average"},{"value":1,"ko":"실효값 측정 (RMS)","en":"True RMS"}],"description":{"ko":"AV/AA 모델만.","en":"AV/AA models only."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":56,"manualAddress":"40057 (0038)","type":"u16","name":{"ko":"표시 주기 (D.REF)","en":"Display period (D.REF)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"100 ms","en":"100 ms"},{"value":1,"ko":"200 ms","en":"200 ms"},{"value":2,"ko":"500 ms","en":"500 ms"},{"value":3,"ko":"1 s","en":"1 s"},{"value":4,"ko":"2 s","en":"2 s"},{"value":5,"ko":"5 s","en":"5 s"}],"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":57,"manualAddress":"40058 (0039)","type":"u16","name":{"ko":"검출 지연 시간 (D.TMR)","en":"Detection delay (D.TMR)"},"access":"rw","fc":[3,6,16],"unit":"s","range":{"min":0,"max":99},"description":{"ko":"0 이면 최대·최소값 표시 없음.","en":"0 disables MAX/MIN display."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":58,"manualAddress":"40059 (003A)","type":"u16","name":{"ko":"외부 입력 선택 (EX.IN)","en":"External input function (EX.IN)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"HOLD","en":"HOLD"},{"value":1,"ko":"ZERO","en":"ZERO"}],"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":59,"manualAddress":"40060 (003B)","type":"u16","name":{"ko":"전면 키 영점 조정 (K-ZO)","en":"Front-key zero adjust (K-ZO)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":60,"manualAddress":"40061 (003C)","type":"u16","name":{"ko":"잠금 선택 (LOCK)","en":"Lock (LOCK)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제","en":"Unlocked"},{"value":1,"ko":"전면 키 잠금 (KEY)","en":"Front keys (KEY)"},{"value":2,"ko":"전체 파라미터 잠금 (PAR)","en":"All parameters (PAR)"},{"value":3,"ko":"전면 키·전체 파라미터 잠금 (K-P)","en":"Keys and all parameters (K-P)"},{"value":4,"ko":"출력 파라미터 잠금 (OUT)","en":"Output parameters (OUT)"},{"value":5,"ko":"전송·통신 출력 파라미터 잠금 (OPT)","en":"Transmission/comm parameters (OPT)"}],"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":61,"manualAddress":"40062 (003D)","type":"u16","name":{"ko":"소수점 위치 (DOT)","en":"Decimal point (DOT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0000","en":"0000"},{"value":1,"ko":"000.0","en":"000.0"},{"value":2,"ko":"00.00","en":"00.00"},{"value":3,"ko":"0.000","en":"0.000"}],"description":{"ko":"측정 모드가 SCALE·FREQ 일 때.","en":"In SCALE or FREQ mode."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":62,"manualAddress":"40063 (003E)","type":"s16","name":{"ko":"프리스케일 상한 (SC-H)","en":"Prescale high (SC-H)"},"access":"rw","fc":[3,6,16],"range":{"min":-9999,"max":9999},"description":{"ko":"측정 모드가 SCALE 일 때. 원시 정수.","en":"SCALE mode only. Raw integer."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":63,"manualAddress":"40064 (003F)","type":"s16","name":{"ko":"프리스케일 하한 (SC-L)","en":"Prescale low (SC-L)"},"access":"rw","fc":[3,6,16],"range":{"min":-9999,"max":9999},"description":{"ko":"측정 모드가 SCALE 일 때. 원시 정수.","en":"SCALE mode only. Raw integer."},"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":64,"manualAddress":"40065 (0040)","type":"u16","name":{"ko":"단위 표시 선택 (UNIT)","en":"Unit display (UNIT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"선택 RANGE 의 단위 램프","en":"Unit of selected range"},{"value":1,"ko":"단위 램프 모두 OFF","en":"All unit lamps OFF"},{"value":2,"ko":"V","en":"V"},{"value":3,"ko":"mV","en":"mV"},{"value":4,"ko":"A","en":"A"},{"value":5,"ko":"mA","en":"mA"},{"value":6,"ko":"W","en":"W"},{"value":7,"ko":"KW","en":"KW"},{"value":8,"ko":"HZ","en":"HZ"}],"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":65,"manualAddress":"40066 (0041)","type":"u16","name":{"ko":"RANGE 표시 선택 (D.RNG)","en":"Range display (D.RNG)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.38 (PDF p.37)","source":0},{"table":"holding-registers","address":100,"manualAddress":"40101 (0064)","type":"u16","name":{"ko":"출력 모드 (O-MD)","en":"Output mode (O-MD)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"출력 OFF","en":"Output OFF"},{"value":1,"ko":"LO 출력 모드","en":"LO output mode"},{"value":2,"ko":"HI 출력 모드","en":"HI output mode"},{"value":3,"ko":"LH 출력 모드","en":"LH output mode"},{"value":4,"ko":"LL 출력 모드","en":"LL output mode"},{"value":5,"ko":"HH 출력 모드","en":"HH output mode"},{"value":6,"ko":"LD 출력 모드","en":"LD output mode"}],"description":{"ko":"출력 있는 모델만.","en":"Output models only."},"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":102,"manualAddress":"40103 (0066)","type":"u16","name":{"ko":"히스테리시스 (HYS)","en":"Hysteresis (HYS)"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":999},"description":{"ko":"최대 표시값의 10 % 이하. 출력 모드가 OFF 면 인식하지 않음.","en":"Up to 10 % of max display. Ignored when output mode is OFF."},"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":103,"manualAddress":"40104 (0067)","type":"s16","name":{"ko":"전송 출력 스케일 상한 (PV.SH)","en":"Retransmission scale high (PV.SH)"},"access":"rw","fc":[3,6,16],"description":{"ko":"전송 출력(4-20 mA) 모델만. PV.SH > PV.SL. 소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Retransmission (4-20 mA) models only. PV.SH > PV.SL. Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":104,"manualAddress":"40105 (0068)","type":"s16","name":{"ko":"전송 출력 스케일 하한 (PV.SL)","en":"Retransmission scale low (PV.SL)"},"access":"rw","fc":[3,6,16],"description":{"ko":"전송 출력(4-20 mA) 모델만. PV.SL < PV.SH. 소수점 위치(DOT)에 따라 원시 정수에 소수점이 붙는다(예 DOT=1 이면 1234 → 123.4).","en":"Retransmission (4-20 mA) models only. PV.SL < PV.SH. Decimal point follows DOT (e.g. DOT=1: raw 1234 = 123.4)."},"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":150,"manualAddress":"40151 (0096)","type":"u16","name":{"ko":"국번 (S-NO)","en":"Station number (S-NO)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":127},"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":151,"manualAddress":"40152 (0097)","type":"u16","name":{"ko":"통신 속도 (BPS)","en":"Baud rate (BPS)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400","en":"2400"},{"value":1,"ko":"4800","en":"4800"},{"value":2,"ko":"9600","en":"9600"},{"value":3,"ko":"19200","en":"19200"},{"value":4,"ko":"38400","en":"38400"}],"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":152,"manualAddress":"40153 (0098)","type":"u16","name":{"ko":"패리티 (PTY)","en":"Parity (PTY)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"NONE","en":"NONE"},{"value":1,"ko":"ODD","en":"ODD"},{"value":2,"ko":"EVEN","en":"EVEN"}],"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":154,"manualAddress":"40155 (009A)","type":"u16","name":{"ko":"응답 대기 시간 (RWT)","en":"Response wait time (RWT)"},"access":"rw","fc":[3,6,16],"unit":"ms","range":{"min":5,"max":99},"ref":"인쇄 p.39 (PDF p.38)","source":0},{"table":"holding-registers","address":155,"manualAddress":"40156 (009B)","type":"u16","name":{"ko":"통신 쓰기 금지 (CWP)","en":"Communication write protect (CWP)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":255,"ko":"ON (FFh)","en":"ON (FFh)"}],"ref":"인쇄 p.39 (PDF p.38)","source":0}],"notes":[{"ko":"통신은 옵션 — 형번 옵션 출력 자리 'C' (LM3-…-3RC/3NC/3PC-A, LM6-…-RC-A) 만 RS485 (인쇄 p.6, PDF p.5).","en":"Communication is optional — only option code 'C' models (LM3-...-3RC/3NC/3PC-A, LM6-...-RC-A) have RS485 (printed p.6, PDF p.5)."},{"ko":"PV·MAX·MIN·비교값·전송 스케일은 소수점 없는 정수로 오가며, 소수점 위치는 DOT(31008/40062)가 정한다.","en":"PV, MAX, MIN, comparison values and retransmission scales are integers without decimal point; DOT (31008/40062) sets the decimal position."},{"ko":"맵에 있는 배율 보정값(40053 SPAN 0.100~5.000)·주파수 입력 지수(40055 FACT)·기동 보상 시간(40102 S.TMR 0.0~99.9 s)·정지 비트(40154)는 원시 값 환산이 적혀 있지 않거나 고정이라 넣지 않았다.","en":"SPAN (40053, 0.100-5.000), FACT (40055), S.TMR (40102, 0.0-99.9 s) and stop bit (40154) are omitted: raw encoding not stated or fixed."},{"ko":"통신 맵은 국문 사용설명서(2023)에만 있다 — 영문 설명서(LM_manual_en_260224, 2쪽)에는 맵이 없다. 이 출처는 LM3·LM6 만 다룬다.","en":"The register map is only in the Korean user manual (2023); the 2-page English manual (LM_manual_en_260224) has none. This source covers LM3 and LM6 only."}],"sources":[{"title":"LM SERIES LCD 디스플레이 멀티패널미터","publisher":"Hanyoung Nux","edition":{"ko":"MF0601K230627_U (PDF 작성 2023-06-28, 파일 LM_user_kr)","en":"MF0601K230627_U (PDF created 2023-06-28, file LM_user_kr)"},"url":"https://www.hanyoungnux.co.kr/data/main.php?down=1586(LM_user_kr).pdf&file_name=LM_user_kr.pdf","pages":{"ko":"인쇄 p.6 형명, p.8 사양, p.27 통신 초기값, p.31~34 통신·프레임 예, p.35~39 맵 (PDF 쪽 = 인쇄 쪽 − 1)","en":"printed p.6 ordering, p.8 specs, p.27 comm defaults, pp.31-34 protocol and frame examples, pp.35-39 map (PDF page = printed page - 1)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"hanyoung-nux/lp","manufacturer":{"ko":"한영넉스","en":"Hanyoung Nux"},"model":"LP Series","models":["LP3-5A5NC","LP3-5A5PC","LP6-5ANC"],"kind":"panel-meter","title":{"ko":"한영넉스 LP 시리즈 LCD 멀티 펄스미터 (RS485 모델)","en":"Hanyoung Nux LP series LCD multi pulse meter (RS485 models)"},"summary":{"ko":"주파수·회전수·속도·주기·시간차·적산 등 13가지 동작 모드의 펄스미터. 형번 끝이 C 인 RS485 모델만 Modbus RTU 슬레이브. 출력 상태 코일, 입력 상태, 램프 상태·모드 입력 레지스터, 동작·입력·출력·통신 설정 보유 레지스터를 담았다.","en":"Pulse meter with 13 operation modes (frequency/speed, period, time difference, totalizing, etc.). Only RS485 models (code ending in C) are Modbus RTU slaves. Covers output-state coils, input states, lamp/mode input registers and operation/input/output/comm holding registers."},"protocols":["rtu"],"comm":{"addressing":"plc","bauds":[2400,4800,9600,19200,38400],"stopBits":1,"unitRange":[1,127],"notes":[{"ko":"매뉴얼은 «00001 (0000)» 처럼 PLC 번호와 괄호 속 16진 통신 주소를 함께 적는다. 통신선 주소 = 괄호 값. 근거: 인쇄 p.38 (PDF p.37) FC01 예 «01 01 00 00 00 03 7C 0B» 가 시작 주소 0x0000 으로 L-OUT·GO-OUT·H-OUT(00001~00003) 3개를 읽고, 응답 «01 01 01 05 91 8B» 의 05 = L-OUT ON·GO-OUT OFF·H-OUT ON. 같은 쪽 FC02 예 «01 02 00 00 00 01 B9 CA» → «01 02 01 01 60 48» 은 HOLD(10001 (0000)) ON. 이 예들과 인쇄 p.40 (PDF p.39) 예외 예(«01 03 00 95 00 07 14 24» → «01 83 02 C0 F1»)의 CRC 를 직접 계산해 모두 맞음을 확인.","en":"The manual writes «00001 (0000)»: PLC number plus hex wire address in brackets; wire address = bracket value. Evidence: FC01 example on printed p.38 (PDF p.37) «01 01 00 00 00 03 7C 0B» reads L-OUT/GO-OUT/H-OUT (00001-00003) from 0x0000; reply «01 01 01 05 91 8B» (05 = L-OUT ON, GO-OUT OFF, H-OUT ON). FC02 example on the same page «01 02 00 00 00 01 B9 CA» → «01 02 01 01 60 48» = HOLD (10001 (0000)) ON. The CRCs of these and of the exception example on printed p.40 (PDF p.39) («01 03 00 95 00 07 14 24» → «01 83 02 C0 F1») were recomputed and all match."},{"ko":"Modbus RTU, RS485 2선 반이중, 최대 31대, 국번 1~127, 2400~38400 bps, 응답 대기 5~99 ms, 정지 비트 1 고정(인쇄 p.8·p.15·p.45). 출하 초기값 표(인쇄 p.17)는 LCD 글꼴 그림이라 국번·속도·패리티 초기값은 넣지 않았다. 데이터 비트 수는 매뉴얼에 없다.","en":"Modbus RTU, RS485 2-wire half duplex, up to 31 units, station 1-127, 2400-38400 bps, response wait 5-99 ms, stop bit fixed 1 (printed pp.8, 15, 45). The factory-default table (printed p.17) is drawn in LCD glyphs, so default station/baud/parity are not given. Data bits are not stated."},{"ko":"지원 함수 코드 01H~04H·06H·10H (인쇄 p.37). 응답 데이터 표기: FC03 «n = 1~16», FC04 «n = 1~22», FC16 «n = 1~20» (인쇄 p.39).","en":"Supported FCs 01h-04h, 06h, 10h (printed p.37). Data count shown as FC03 'n = 1-16', FC04 'n = 1-22', FC16 'n = 1-20' (printed p.39)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"00001 (0000)","type":"bit","name":{"ko":"L-OUT 출력 상태","en":"L-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"3단·5단 출력 모델만","en":"3- and 5-stage output models only"},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"coils","address":1,"manualAddress":"00002 (0001)","type":"bit","name":{"ko":"GO-OUT 출력 상태","en":"GO-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"3단·5단 출력 모델만","en":"3- and 5-stage output models only"},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"coils","address":2,"manualAddress":"00003 (0002)","type":"bit","name":{"ko":"H-OUT 출력 상태","en":"H-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"3단·5단 출력 모델만","en":"3- and 5-stage output models only"},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"coils","address":3,"manualAddress":"00004 (0003)","type":"bit","name":{"ko":"LL-OUT 출력 상태","en":"LL-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"5단 출력 모델만","en":"5-stage output models only"},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"coils","address":4,"manualAddress":"00005 (0004)","type":"bit","name":{"ko":"HH-OUT 출력 상태","en":"HH-OUT output state"},"access":"r","fc":[1],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"5단 출력 모델만","en":"5-stage output models only"},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"discrete-inputs","address":0,"manualAddress":"10001 (0000)","type":"bit","name":{"ko":"HOLD/RESET 입력 상태","en":"HOLD/RESET input state"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"discrete-inputs","address":1,"manualAddress":"10002 (0001)","type":"bit","name":{"ko":"BANK 입력 상태","en":"BANK input state"},"access":"r","fc":[2],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"description":{"ko":"LP3 만","en":"LP3 only"},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"input-registers","address":102,"manualAddress":"30103 (0066)","type":"u16","name":{"ko":"하드웨어 버전","en":"Hardware version"},"access":"r","fc":[4],"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"input-registers","address":103,"manualAddress":"30104 (0067)","type":"u16","name":{"ko":"펌웨어 버전","en":"Firmware version"},"access":"r","fc":[4],"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"input-registers","address":104,"manualAddress":"30105 (0068)","type":"u16","name":{"ko":"모델 이름(ASCII)","en":"Model name (ASCII)"},"access":"r","fc":[4],"description":{"ko":"매뉴얼 표기 \"LP\" (ASCII 코드).","en":"Manual shows \"LP\" (ASCII code)."},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"input-registers","address":105,"manualAddress":"30106 (0069)","type":"u16","name":{"ko":"외형(ASCII)","en":"Case size (ASCII)"},"access":"r","fc":[4],"description":{"ko":"ASCII \"3\" = LP3, \"6\" = LP6.","en":"ASCII \"3\" = LP3, \"6\" = LP6."},"ref":"인쇄 p.41 (PDF p.40)","source":0},{"table":"input-registers","address":1000,"manualAddress":"31001 (03E8)","type":"u16","name":{"ko":"동작 램프 표시 상태","en":"Active lamp status (ACTIVE-LAMP)"},"access":"r","fc":[4],"bits":[{"bit":1,"ko":"LL-OUT 램프","en":"LL-OUT lamp"},{"bit":2,"ko":"L-OUT 램프","en":"L-OUT lamp"},{"bit":3,"ko":"GO-OUT 램프","en":"GO-OUT lamp"},{"bit":4,"ko":"H-OUT 램프","en":"H-OUT lamp"},{"bit":5,"ko":"HH-OUT 램프","en":"HH-OUT lamp"},{"bit":10,"ko":"CWP 램프","en":"CWP lamp"},{"bit":11,"ko":"LOCK 램프","en":"LOCK lamp"},{"bit":12,"ko":"HOLD 램프","en":"HOLD lamp"},{"bit":13,"ko":"RESET 램프","en":"RESET lamp"},{"bit":14,"ko":"MIN 램프","en":"MIN lamp"},{"bit":15,"ko":"MAX 램프","en":"MAX lamp"}],"description":{"ko":"비트 0·6~9 는 RESERVED. 각 비트 0 = OFF, 1 = ON.","en":"Bits 0 and 6-9 reserved. Each bit 0 = OFF, 1 = ON."},"ref":"인쇄 p.42 (PDF p.41)","source":0},{"table":"input-registers","address":1001,"manualAddress":"31002 (03E9)","type":"u16","name":{"ko":"설정 램프 표시 상태","en":"Set lamp status (SET-LAMP)"},"access":"r","fc":[4],"bits":[{"bit":1,"ko":"BANK_2 램프","en":"BANK_2 lamp"},{"bit":2,"ko":"BANK_1 램프","en":"BANK_1 lamp"},{"bit":3,"ko":"BANK 램프","en":"BANK lamp"},{"bit":4,"ko":"LL-SET 램프","en":"LL-SET lamp"},{"bit":5,"ko":"L-SET 램프","en":"L-SET lamp"},{"bit":6,"ko":"H-SET 램프","en":"H-SET lamp"},{"bit":7,"ko":"HH-SET 램프","en":"HH-SET lamp"}],"description":{"ko":"비트 0·8~15 는 RESERVED.","en":"Bits 0 and 8-15 reserved."},"ref":"인쇄 p.42 (PDF p.41)","source":0},{"table":"input-registers","address":1018,"manualAddress":"31019 (03FA)","type":"u16","name":{"ko":"소수점 위치 (DOT)","en":"Decimal point (DOT)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"00000","en":"00000"},{"value":1,"ko":"0000.0","en":"0000.0"},{"value":2,"ko":"000.00","en":"000.00"},{"value":3,"ko":"00.000","en":"00.000"},{"value":4,"ko":"0.0000","en":"0.0000"}],"ref":"인쇄 p.42 (PDF p.41)","source":0},{"table":"input-registers","address":1019,"manualAddress":"31020 (03FB)","type":"u16","name":{"ko":"시간 진법 (SCAL)","en":"Time scale (SCAL)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"10진법","en":"Decimal"},{"value":1,"ko":"60진법","en":"Sexagesimal (60)"}],"ref":"인쇄 p.42 (PDF p.41)","source":0},{"table":"input-registers","address":1020,"manualAddress":"31021 (03FC)","type":"u16","name":{"ko":"시간 범위 (RANG)","en":"Time range (RANG)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"0.01 s","en":"0.01 s"},{"value":1,"ko":"0.1 s","en":"0.1 s"},{"value":2,"ko":"초(SEC)","en":"Seconds (SEC)"},{"value":3,"ko":"분(MIN)","en":"Minutes (MIN)"}],"ref":"인쇄 p.42 (PDF p.41)","source":0},{"table":"input-registers","address":1021,"manualAddress":"31022 (03FD)","type":"u16","name":{"ko":"동작 모드 (FUNC)","en":"Operation mode (FUNC)"},"access":"r","fc":[4],"values":[{"value":0,"ko":"F1 주파수/회전수/속도","en":"F1 frequency/speed"},{"value":1,"ko":"F2 이동 속도","en":"F2 travel speed"},{"value":2,"ko":"F3 주기","en":"F3 period"},{"value":3,"ko":"F4 통과 시간","en":"F4 passing time"},{"value":4,"ko":"F5 시간차","en":"F5 time difference"},{"value":5,"ko":"F6 시간 폭","en":"F6 time width"},{"value":6,"ko":"F7 측정 길이","en":"F7 length"},{"value":7,"ko":"F8 간격","en":"F8 interval"},{"value":8,"ko":"F9 적산","en":"F9 totalizing"},{"value":9,"ko":"F10 절대 비율","en":"F10 absolute ratio"},{"value":10,"ko":"F11 오차 비율","en":"F11 error ratio"},{"value":11,"ko":"F12 농도","en":"F12 density"},{"value":12,"ko":"F13 오차","en":"F13 error"}],"ref":"인쇄 p.42 (PDF p.41)","source":0},{"table":"holding-registers","address":50,"manualAddress":"40051 (0032)","type":"u16","name":{"ko":"동작 모드 (FUNC)","en":"Operation mode (FUNC)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"F1 주파수/회전수/속도","en":"F1 frequency/speed"},{"value":1,"ko":"F2 이동 속도","en":"F2 travel speed"},{"value":2,"ko":"F3 주기","en":"F3 period"},{"value":3,"ko":"F4 통과 시간","en":"F4 passing time"},{"value":4,"ko":"F5 시간차","en":"F5 time difference"},{"value":5,"ko":"F6 시간 폭","en":"F6 time width"},{"value":6,"ko":"F7 측정 길이","en":"F7 length"},{"value":7,"ko":"F8 간격","en":"F8 interval"},{"value":8,"ko":"F9 적산","en":"F9 totalizing"},{"value":9,"ko":"F10 절대 비율","en":"F10 absolute ratio"},{"value":10,"ko":"F11 오차 비율","en":"F11 error ratio"},{"value":11,"ko":"F12 농도","en":"F12 density"},{"value":12,"ko":"F13 오차","en":"F13 error"}],"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":51,"manualAddress":"40052 (0033)","type":"u16","name":{"ko":"입력 A 센서 종류 (IN-A)","en":"Input A sensor type (IN-A)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"NPN-L","en":"NPN-L"},{"value":1,"ko":"NPN-H","en":"NPN-H"},{"value":2,"ko":"PNP-L","en":"PNP-L"},{"value":3,"ko":"PNP-H","en":"PNP-H"}],"description":{"ko":"접점 입력이면 NPN-L 또는 PNP-L.","en":"For contact input use NPN-L or PNP-L."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":52,"manualAddress":"40053 (0034)","type":"u16","name":{"ko":"입력 B 센서 종류 (IN-B)","en":"Input B sensor type (IN-B)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"NPN-L","en":"NPN-L"},{"value":1,"ko":"NPN-H","en":"NPN-H"},{"value":2,"ko":"PNP-L","en":"PNP-L"},{"value":3,"ko":"PNP-H","en":"PNP-H"}],"description":{"ko":"F2/F5/F7/F8/F9/F10/F11/F13 모드에서만.","en":"Only in F2/F5/F7/F8/F9/F10/F11/F13 modes."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":53,"manualAddress":"40054 (0035)","type":"u16","name":{"ko":"출력 모드 (O-MD)","en":"Output mode (O-MD)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OUT-S","en":"OUT-S"},{"value":1,"ko":"OUT-H","en":"OUT-H"},{"value":2,"ko":"OUT-L","en":"OUT-L"},{"value":3,"ko":"OUT-B","en":"OUT-B"},{"value":4,"ko":"OUT-F","en":"OUT-F"},{"value":5,"ko":"OUT-D","en":"OUT-D"}],"description":{"ko":"F9 모드는 OUT-H 고정. 출력 모델만.","en":"F9 mode is fixed to OUT-H. Output models only."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":56,"manualAddress":"40057 (0038)","type":"s16","name":{"ko":"입력 A 프리스케일 지수 (P-AY)","en":"Input A prescale exponent (P-AY)"},"access":"rw","fc":[3,6,16],"range":{"min":-9,"max":9},"description":{"ko":"10 의 거듭제곱 지수(10^-9 ~ 10^9).","en":"Power-of-ten exponent (10^-9 to 10^9)."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":59,"manualAddress":"40060 (003B)","type":"s16","name":{"ko":"입력 B 프리스케일 지수 (P-BY)","en":"Input B prescale exponent (P-BY)"},"access":"rw","fc":[3,6,16],"range":{"min":-9,"max":9},"description":{"ko":"F10/F11/F12/F13 모드에서만.","en":"Only in F10/F11/F12/F13 modes."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":60,"manualAddress":"40061 (003C)","type":"u16","name":{"ko":"소수점 위치 (DOT)","en":"Decimal point (DOT)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"00000","en":"00000"},{"value":1,"ko":"0000.0","en":"0000.0"},{"value":2,"ko":"000.00","en":"000.00"},{"value":3,"ko":"00.000","en":"00.000"},{"value":4,"ko":"0.0000","en":"0.0000"}],"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":61,"manualAddress":"40062 (003D)","type":"u16","name":{"ko":"시간 진법 (SCAL)","en":"Time scale (SCAL)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"10진법","en":"Decimal"},{"value":1,"ko":"60진법","en":"Sexagesimal (60)"}],"description":{"ko":"F3/F4/F5/F6 모드에서만.","en":"Only in F3/F4/F5/F6 modes."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":62,"manualAddress":"40063 (003E)","type":"u16","name":{"ko":"시간 범위 (RANG)","en":"Time range (RANG)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0.01 s","en":"0.01 s"},{"value":1,"ko":"0.1 s","en":"0.1 s"},{"value":2,"ko":"초(SEC)","en":"Seconds (SEC)"},{"value":3,"ko":"분(MIN)","en":"Minutes (MIN)"}],"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":63,"manualAddress":"40064 (003F)","type":"u16","name":{"ko":"표시 주기 (D-REF)","en":"Display refresh period (D-REF)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0.05 s","en":"0.05 s"},{"value":1,"ko":"0.5 s","en":"0.5 s"},{"value":2,"ko":"1 s","en":"1 s"},{"value":3,"ko":"2 s","en":"2 s"},{"value":4,"ko":"4 s","en":"4 s"},{"value":5,"ko":"8 s","en":"8 s"}],"description":{"ko":"F1/F10/F11/F12/F13 모드에서만.","en":"Only in F1/F10/F11/F12/F13 modes."},"ref":"인쇄 p.44 (PDF p.43)","source":0},{"table":"holding-registers","address":100,"manualAddress":"40101 (0064)","type":"u16","name":{"ko":"히스테리시스 (HYS)","en":"Hysteresis (HYS)"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"description":{"ko":"소수점 위치에 따라 범위가 달라진다. 출력 모델만.","en":"Range depends on decimal point. Output models only."},"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":105,"manualAddress":"40106 (0069)","type":"u16","name":{"ko":"L·LL 출력 제한 (O-LIM)","en":"L/LL output limit (O-LIM)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"L-OUT","en":"L-OUT"},{"value":1,"ko":"S-TIM(기동 보상)","en":"S-TIM (start-up compensation)"}],"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":107,"manualAddress":"40108 (006B)","type":"u16","name":{"ko":"정전 기억 (BACK)","en":"Power-failure memory (BACK)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"CLR","en":"CLR"},{"value":1,"ko":"SAVE","en":"SAVE"}],"description":{"ko":"F9 모드에서만.","en":"F9 mode only."},"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":108,"manualAddress":"40109 (006C)","type":"u16","name":{"ko":"BANK 전환 (B-CHG)","en":"BANK change (B-CHG)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"KEY","en":"KEY"},{"value":2,"ko":"EX-IN(외부 입력)","en":"EX-IN (external input)"}],"description":{"ko":"LP3 만.","en":"LP3 only."},"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":109,"manualAddress":"40110 (006D)","type":"u16","name":{"ko":"잠금 (LOCK)","en":"Lock (LOCK)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"KEY","en":"KEY"},{"value":2,"ko":"PAR","en":"PAR"},{"value":3,"ko":"K-P","en":"K-P"},{"value":4,"ko":"BNK","en":"BNK"},{"value":5,"ko":"OPT","en":"OPT"}],"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":110,"manualAddress":"40111 (006E)","type":"u16","name":{"ko":"BANK 번호 (BANK)","en":"BANK number (BANK)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"BANK #1","en":"BANK #1"},{"value":1,"ko":"BANK #2","en":"BANK #2"}],"description":{"ko":"B-CHG 가 KEY 일 때만 바꿀 수 있다. LP3 만.","en":"Changeable only when B-CHG is KEY. LP3 only."},"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":150,"manualAddress":"40151 (0096)","type":"u16","name":{"ko":"국번 (S-NO)","en":"Station number (S-NO)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":127},"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":151,"manualAddress":"40152 (0097)","type":"u16","name":{"ko":"통신 속도 (BPS)","en":"Baud rate (BPS)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"}],"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":152,"manualAddress":"40153 (0098)","type":"u16","name":{"ko":"패리티 (PTY)","en":"Parity (PTY)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수","en":"Even"}],"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":153,"manualAddress":"40154 (0099)","type":"u16","name":{"ko":"정지 비트 (STOP)","en":"Stop bits (STOP)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1 비트 고정","en":"1 bit (fixed)"}],"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":154,"manualAddress":"40155 (009A)","type":"u16","name":{"ko":"응답 대기 시간 (RWT)","en":"Response wait time (RWT)"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":5,"max":99},"ref":"인쇄 p.45 (PDF p.44)","source":0},{"table":"holding-registers","address":155,"manualAddress":"40156 (009B)","type":"u16","name":{"ko":"통신 쓰기 금지 (CWP)","en":"Communication write protect (CWP)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF","en":"OFF"},{"value":1,"ko":"ON","en":"ON"}],"ref":"인쇄 p.45 (PDF p.44)","source":0}],"notes":[{"ko":"RS485 는 형번 끝 C 모델만: LP3-5A5NC·LP3-5A5PC(5단 출력 + RS485), LP6-5ANC(지시 전용 + RS485) (인쇄 p.6 (PDF p.5) 주문 정보).","en":"RS485 only on models ending in C: LP3-5A5NC, LP3-5A5PC (5-stage output + RS485), LP6-5ANC (indicator + RS485) (ordering info, printed p.6 (PDF p.5))."},{"ko":"측정값 PV·MAX·MIN(31003~31008), 비교값 LSV·HSV·LLSV·HHSV·DSV(31009~31018, 40001~40010), 프리스케일 가수 P-AX·P-BX(40055~40056·40058~40059), Auto-zero 시간 AZ-A·AZ-B(40102~40105)는 «Double Word 로 멀티 전송» 이라고만 적혀 있고 두 워드 중 어느 쪽이 상위인지(워드 순서)·배율이 매뉴얼에 없어 넣지 않았다.","en":"PV/MAX/MIN (31003-31008), set values LSV/HSV/LLSV/HHSV/DSV (31009-31018, 40001-40010), prescale mantissas P-AX/P-BX (40055-40056, 40058-40059) and auto-zero times AZ-A/AZ-B (40102-40105) are only described as 'double word, multi-register transfer'; the word order and scaling are not stated, so they are omitted."},{"ko":"기동 보상 시간 S-TMR(40107 (006A), 0.0~99.9 s)은 원시 값 배율이 적혀 있지 않아 넣지 않았다. 제품 번호(30101~30102)와 BANK #1·#2 묶음(40161~40180·40201~40220, LP3 만)도 뺐다 — 필요하면 인쇄 p.46~47 참조.","en":"Start-up compensation time S-TMR (40107 (006A), 0.0-99.9 s) is omitted because its raw scaling is not stated. Product number (30101-30102) and the BANK #1/#2 blocks (40161-40180, 40201-40220, LP3 only) are also omitted — see printed pp.46-47."},{"ko":"예외 코드 1 = 지원하지 않는 명령, 2 = 시작 번지 불일치, 3 = 개수 불일치, 4 = 처리 실패 (인쇄 p.40). 통신 쓰기 금지(CWP) ON 이면 쓰기가 막힌다.","en":"Exception codes 1 = unsupported function, 2 = start address mismatch, 3 = quantity mismatch, 4 = processing failure (printed p.40). Writes are blocked while CWP is ON."},{"ko":"쪽 번호: 이 PDF 는 인쇄 쪽 = PDF 쪽 + 1.","en":"Page numbers: in this PDF, printed page = PDF page + 1."}],"sources":[{"title":"LP SERIES LCD Multi Pulsemeter 사용설명서","publisher":"Hanyoung Nux","edition":{"ko":"MF0601K240828_U (PDF 작성 2024-08-28)","en":"MF0601K240828_U (PDF created 2024-08-28)"},"url":"https://www.hanyoungnux.co.kr/data/main.php?down=2487(LP_user_kr).pdf&file_name=LP_user_kr.pdf","pages":{"ko":"인쇄 p.37~47 (PDF p.36~46) 통신, p.6 주문 정보, p.8·p.15 통신 사양","en":"printed pp.37-47 (PDF pp.36-46) communication, p.6 ordering, pp.8, 15 comm spec"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"hanyoung-nux/vx","manufacturer":{"ko":"한영넉스","en":"Hanyoung Nux"},"model":"VX Series","models":["VX2","VX4","VX7","VX9"],"kind":"temperature-controller","title":{"ko":"한영넉스 VX 시리즈 온도 조절기","en":"Hanyoung Nux VX series temperature controller"},"summary":{"ko":"RS485 2선식. Modbus RTU/ASCII 에서 D-레지스터를 FC 03/06/16 으로 읽고 쓴다. 온도 값의 소수점은 DP-P 에 따른다.","en":"RS485 2-wire. Modbus RTU/ASCII access to D-registers with FC 03/06/16. Temperature decimals follow DP-P."},"protocols":["rtu","ascii"],"comm":{"addressing":"zero","baud":9600,"bauds":[4800,9600,14400,19200,38400,57600],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,99],"maxRegisters":31,"notes":[{"ko":"통신선 주소 = 매뉴얼 맵의 «D-register» 열(0 기준). 같은 표의 «Address» 열은 1 큰 1 기준 번호다. 근거: p.30~36(PDF 31~37) 프레임 예에서 SV-1(D-register 103)을 0x0067 로 보냄, p.93(PDF 94) 맵에서 SV-1 = Address 104 / D-register 103.","en":"Wire address = the map's 'D-register' column (0-based). The 'Address' column is 1-based (one higher). Evidence: frame examples p.30-36 (PDF 31-37) send SV-1 (D-register 103) as 0x0067; map p.93 (PDF 94) lists SV-1 as Address 104 / D-register 103."},{"ko":"공장 초기값: 프로토콜 PRS = 0(PC Link STD) — Modbus RTU 로 쓰려면 PRS 를 3 으로 바꿔야 한다. 속도 9600(BPS=1), 패리티 없음, 스톱 1, 데이터 8, 주소 1, 응답 지연 0 (p.103~104, PDF 104~105 G.COM 초기값 열).","en":"Factory defaults: protocol PRS = 0 (PC Link STD) — set PRS = 3 for Modbus RTU. 9600 bps (BPS=1), no parity, 1 stop, 8 data, address 1, response delay 0 (p.103-104, PDF 104-105, G.COM default column)."},{"ko":"FC 03 은 한 번에 최대 31개, FC 16 은 최대 32개(p.29·p.35). FC 08(루프백 진단)도 지원. 주소 0 은 브로드캐스트(응답 없음). Modbus ASCII 는 7비트, RTU 는 8비트로 동작(p.28).","en":"FC 03 reads up to 31 registers, FC 16 writes up to 32 (p.29, p.35). FC 08 loopback diagnostics also supported. Address 0 = broadcast (no reply). ASCII runs 7-bit, RTU 8-bit (p.28)."},{"ko":"p.38 에는 LS·미쓰비시 PLC 에서 «D 를 4 로 바꿔 40103» 처럼 쓰라는 설명이 있다. 이는 PLC 쪽 표기 안내이고, 통신선 주소는 위 프레임 예를 따른다.","en":"p.38 tells LS/Mitsubishi PLC users to write D0103 as 40103. That is a host-side notation hint; the wire address follows the frame examples above."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"D-register 0 (0000h) / Address 1","type":"s16","name":{"ko":"현재 온도(PV)","en":"Present value (PV)"},"access":"r","fc":[3],"description":{"ko":"CPV. 소수점은 DP-P(D3·D904)에 따른다 — 입력 종류에 따라 달라지므로 scale 없음. 표시 범위 EU -5.0~105.0 %.","en":"CPV. Decimal places follow DP-P (D3/D904), which depends on input type, so no fixed scale. Range EU -5.0 to 105.0 %."},"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":1,"manualAddress":"D-register 1 (0001h) / Address 2","type":"s16","name":{"ko":"현재 설정 온도(SV)","en":"Current set value (SV)"},"access":"r","fc":[3],"description":{"ko":"CSV. 소수점은 DP-P 에 따른다. 범위 SV-L~SV-H.","en":"CSV. Decimals follow DP-P. Range SV-L to SV-H."},"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":2,"manualAddress":"D-register 2 (0002h) / Address 3","type":"s16","name":{"ko":"최종 설정 온도","en":"Target SV (final)"},"access":"r","fc":[3],"description":{"ko":"TSV. 소수점은 DP-P 에 따른다.","en":"TSV. Decimals follow DP-P."},"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":3,"manualAddress":"D-register 3 (0003h) / Address 4","type":"u16","name":{"ko":"소수점 위치","en":"Decimal point position"},"access":"r","fc":[3],"range":{"min":0,"max":3},"description":{"ko":"DP-P(읽기용). 온도 값 레지스터의 소수 자릿수. 설정은 D904.","en":"DP-P (read copy). Number of decimals for temperature values. Set via D904."},"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":4,"manualAddress":"D-register 4 (0004h) / Address 5","type":"u16","name":{"ko":"단위","en":"Unit"},"access":"r","fc":[3],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"},{"value":2,"ko":"%","en":"%"},{"value":3,"ko":"무단위","en":"none"}],"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":5,"manualAddress":"D-register 5 (0005h) / Address 6","type":"s16","name":{"ko":"출력량(MV)","en":"Output (MV)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"range":{"min":-5,"max":105},"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":6,"manualAddress":"D-register 6 (0006h) / Address 7","type":"s16","name":{"ko":"가열 출력량","en":"Heating output (OUT1)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"일반형 -5.0~105.0 %, 가열/냉각형 0.0~105.0 %.","en":"Standard: -5.0 to 105.0 %; heat/cool type: 0.0 to 105.0 %."},"ref":"p.90 (PDF 91) 6.1 Process"},{"table":"holding-registers","address":9,"manualAddress":"D-register 9 (0009h) / Address 10","type":"u16","name":{"ko":"현재 SV 번호","en":"Active SV number"},"access":"r","fc":[3],"range":{"min":1,"max":4},"description":{"ko":"1~3: SV-1~SV-3, 4: SV-4(리모트 사용 시 REM 포함).","en":"1-3: SV-1 to SV-3; 4: SV-4 (includes REM when remote enabled)."},"ref":"p.91 (PDF 92) 6.1 Process"},{"table":"holding-registers","address":10,"manualAddress":"D-register 10 (000Ah) / Address 11","type":"u16","name":{"ko":"현재 상태","en":"Status (NOW_STS)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"0 정지(모니터링) / 1 운전","en":"0 stop (monitor) / 1 run"},{"bit":1,"ko":"1 오토튜닝 중","en":"1 auto-tuning"},{"bit":2,"ko":"0 자동 출력 / 1 수동 출력","en":"0 auto output / 1 manual output"},{"bit":3,"ko":"0 SV 번호 사용 / 1 리모트(REM) 사용","en":"0 SV.NO / 1 remote (REM)"},{"bit":4,"ko":"1 램프 사용","en":"1 ramp in use"},{"bit":5,"ko":"0 가열 제어 / 1 가열·냉각 제어","en":"0 heating / 1 heat-cool"},{"bit":7,"ko":"1 잠금 설정","en":"1 locked"}],"ref":"p.91 (PDF 92), p.112 (PDF 113) 6.3 BIT Information"},{"table":"holding-registers","address":11,"manualAddress":"D-register 11 (000Bh) / Address 12","type":"u16","name":{"ko":"에러 상태","en":"Error status (ERR_STS)"},"access":"r","fc":[3],"bits":[{"bit":5,"ko":"PV -OVER","en":"PV under-range (-OVER)"},{"bit":6,"ko":"PV +OVER","en":"PV over-range (+OVER)"},{"bit":7,"ko":"번아웃(단선)","en":"Burn-out"},{"bit":8,"ko":"통신 오류","en":"Communication error"},{"bit":9,"ko":"오토튜닝 오류","en":"Auto-tuning error"},{"bit":10,"ko":"RJC 오류","en":"RJC error"},{"bit":11,"ko":"교정 오류","en":"Calibration error"},{"bit":12,"ko":"ADC 오류","en":"ADC error"},{"bit":13,"ko":"EEPROM 오류","en":"EEPROM error"},{"bit":14,"ko":"옵션 코드 오류","en":"Option code error"},{"bit":15,"ko":"시스템 코드 오류","en":"System code error"}],"ref":"p.91 (PDF 92), p.113 (PDF 114)"},{"table":"holding-registers","address":12,"manualAddress":"D-register 12 (000Ch) / Address 13","type":"u16","name":{"ko":"보조 출력 상태","en":"Sub output status (SUB_STS)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"SUB1 출력","en":"SUB1 on"},{"bit":1,"ko":"SUB2 출력","en":"SUB2 on"},{"bit":2,"ko":"SUB3 출력","en":"SUB3 on"},{"bit":3,"ko":"SUB4 출력","en":"SUB4 on"}],"ref":"p.91 (PDF 92), p.113 (PDF 114)"},{"table":"holding-registers","address":13,"manualAddress":"D-register 13 (000Dh) / Address 14","type":"u16","name":{"ko":"경보 상태","en":"Alarm status (ALM_STS)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"경보 1","en":"Alarm 1"},{"bit":1,"ko":"경보 2","en":"Alarm 2"},{"bit":2,"ko":"경보 3","en":"Alarm 3"},{"bit":3,"ko":"경보 4","en":"Alarm 4"},{"bit":9,"ko":"루프 단선 경보(LBA)","en":"Loop break alarm (LBA)"},{"bit":10,"ko":"히터 단선 경보(HBA)","en":"Heater break alarm (HBA)"}],"ref":"p.91 (PDF 92), p.114 (PDF 115)"},{"table":"holding-registers","address":14,"manualAddress":"D-register 14 (000Eh) / Address 15","type":"u16","name":{"ko":"DI 상태","en":"Digital input status (DI_STS)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"DI1 입력","en":"DI1 on"},{"bit":1,"ko":"DI2 입력","en":"DI2 on"},{"bit":2,"ko":"DI3 입력","en":"DI3 on"},{"bit":3,"ko":"DI4 입력","en":"DI4 on"}],"ref":"p.91 (PDF 92), p.114 (PDF 115)"},{"table":"holding-registers","address":15,"manualAddress":"D-register 15 (000Fh) / Address 16","type":"u16","name":{"ko":"CT1 전류","en":"CT1 current"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":55},"ref":"p.91 (PDF 92) 6.1 Process"},{"table":"holding-registers","address":17,"manualAddress":"D-register 17 (0011h) / Address 18","type":"u16","name":{"ko":"운전/정지 상태","en":"Run/stop state"},"access":"r","fc":[3],"values":[{"value":0,"ko":"정지","en":"Stop"},{"value":1,"ko":"운전","en":"Run"}],"ref":"p.91 (PDF 92) 6.1 Process"},{"table":"holding-registers","address":31,"manualAddress":"D-register 31 (001Fh) / Address 32","type":"u16","name":{"ko":"자동/수동 전환","en":"Auto/manual select"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"자동 출력","en":"Auto"},{"value":1,"ko":"수동 출력","en":"Manual"}],"ref":"p.91 (PDF 92) 6.1 Process"},{"table":"holding-registers","address":32,"manualAddress":"D-register 32 (0020h) / Address 33","type":"s16","name":{"ko":"수동 출력량 입력","en":"Manual MV input"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":-5,"max":105},"description":{"ko":"원시 값 -50~1050. (매뉴얼 괄호 안 범위는 «-50.0~105.0 %» 로 적혀 있어 원시 값과 어긋남 — 원시 값 기준으로 적음.)","en":"Raw -50 to 1050. (The manual's bracketed range reads '-50.0 to 105.0 %', inconsistent with the raw range; raw range used.)"},"ref":"p.92 (PDF 93) 6.1 Process"},{"table":"holding-registers","address":33,"manualAddress":"D-register 33 (0021h) / Address 34","type":"u16","name":{"ko":"운전/정지 명령","en":"Run/stop command"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"정지","en":"Stop"},{"value":1,"ko":"운전","en":"Run"}],"ref":"p.92 (PDF 93) 6.1 Process"},{"table":"holding-registers","address":45,"manualAddress":"D-register 45 (002Dh) / Address 46","type":"u16","name":{"ko":"펌웨어 버전","en":"Firmware version"},"access":"r","fc":[3],"description":{"ko":"맵의 소수점 열이 2 — 소수 둘째 자리까지로 읽는 것으로 보임(예시 값은 매뉴얼에 없음).","en":"Map decimal column is 2 (two decimals implied; no example given)."},"ref":"p.92 (PDF 93) 6.1 Process"},{"table":"holding-registers","address":100,"manualAddress":"D-register 100 (0064h) / Address 101","type":"u16","name":{"ko":"SV 번호 선택","en":"SV number select"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":4},"ref":"p.93 (PDF 94) G.SV"},{"table":"holding-registers","address":101,"manualAddress":"D-register 101 (0065h) / Address 102","type":"s16","name":{"ko":"SV 상한","en":"SV high limit (SV-H)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점은 DP-P. EU 0.0~100.0 %, SV-L < SV-H.","en":"Decimals per DP-P. EU 0.0-100.0 %, SV-L < SV-H."},"ref":"p.93 (PDF 94) G.SV"},{"table":"holding-registers","address":102,"manualAddress":"D-register 102 (0066h) / Address 103","type":"s16","name":{"ko":"SV 하한","en":"SV low limit (SV-L)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점은 DP-P.","en":"Decimals per DP-P."},"ref":"p.93 (PDF 94) G.SV"},{"table":"holding-registers","address":103,"manualAddress":"D-register 103 (0067h) / Address 104","type":"s16","name":{"ko":"설정값 1 (SV-1)","en":"Set value 1 (SV-1)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점은 DP-P(예 DP-P=1 이면 1000 → 100.0). SV-L ≤ SV-1 ≤ SV-H. 프레임 예는 p.30~36.","en":"Decimals per DP-P (e.g. DP-P=1: 1000 → 100.0). SV-L ≤ SV-1 ≤ SV-H. Frame examples on pp.30-36."},"ref":"p.93 (PDF 94) G.SV"},{"table":"holding-registers","address":104,"manualAddress":"D-register 104 (0068h) / Address 105","type":"s16","name":{"ko":"설정값 2 (SV-2)","en":"Set value 2 (SV-2)"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점은 DP-P.","en":"Decimals per DP-P."},"ref":"p.93 (PDF 94) G.SV"},{"table":"holding-registers","address":207,"manualAddress":"D-register 207 (00CFh) / Address 208","type":"u16","name":{"ko":"오토튜닝","en":"Auto-tuning"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"끔","en":"Off"},{"value":1,"ko":"켬(실행)","en":"On (start)"}],"ref":"p.94 (PDF 95) G.CTL"},{"table":"holding-registers","address":210,"manualAddress":"D-register 210 (00D2h) / Address 211","type":"s16","name":{"ko":"비례대 1 (가열)","en":"Proportional band 1 (heat)"},"access":"rw","fc":[3,6,16],"description":{"ko":"1.P. 온도 단위 값이며 소수점은 DP-P. EUS 0.0~100.0 %, 초기 EUS 5.0 %.","en":"1.P. In engineering units, decimals per DP-P. EUS 0.0-100.0 %, default EUS 5.0 %."},"ref":"p.94 (PDF 95) G.CTL"},{"table":"holding-registers","address":211,"manualAddress":"D-register 211 (00D3h) / Address 212","type":"u16","name":{"ko":"적분 시간 1 (가열)","en":"Integral time 1 (heat)"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":6000},"description":{"ko":"0 = 끔. 초기 240.","en":"0 = off. Default 240."},"ref":"p.94 (PDF 95) G.CTL"},{"table":"holding-registers","address":212,"manualAddress":"D-register 212 (00D4h) / Address 213","type":"u16","name":{"ko":"미분 시간 1 (가열)","en":"Derivative time 1 (heat)"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":6000},"description":{"ko":"0 = 끔. 초기 60.","en":"0 = off. Default 60."},"ref":"p.94 (PDF 95) G.CTL"},{"table":"holding-registers","address":300,"manualAddress":"D-register 300 (012Ch) / Address 301","type":"u16","name":{"ko":"경보 1 종류","en":"Alarm 1 type"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":13},"description":{"ko":"0 = 끔, 1~13 경보 종류(제품 사용설명서 참조). 초기 3.","en":"0 = off, 1-13 alarm types (see product manual). Default 3."},"ref":"p.97 (PDF 98) G.ALM"},{"table":"holding-registers","address":301,"manualAddress":"D-register 301 (012Dh) / Address 302","type":"s16","name":{"ko":"경보 1 설정값","en":"Alarm 1 set value"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점은 DP-P. 절대 경보 EU 0.0~100.0 %, 편차 경보 EUS 0.0~100.0 %.","en":"Decimals per DP-P. Absolute: EU 0.0-100.0 %; deviation: EUS 0.0-100.0 %."},"ref":"p.97 (PDF 98) G.ALM"},{"table":"holding-registers","address":600,"manualAddress":"D-register 600 (0258h) / Address 601","type":"u16","name":{"ko":"통신 프로토콜","en":"Protocol (PRS)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"PC Link STD (초기값)","en":"PC Link STD (default)"},{"value":1,"ko":"PC Link SUM","en":"PC Link with sum"},{"value":2,"ko":"Modbus ASCII","en":"Modbus ASCII"},{"value":3,"ko":"Modbus RTU","en":"Modbus RTU"},{"value":4,"ko":"MC4 (MC 프로토콜 형식 4)","en":"MC4"},{"value":5,"ko":"XGT","en":"XGT"}],"ref":"p.103 (PDF 104) G.COM"},{"table":"holding-registers","address":601,"manualAddress":"D-register 601 (0259h) / Address 602","type":"u16","name":{"ko":"통신 속도","en":"Baud rate (BPS)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"4800","en":"4800"},{"value":1,"ko":"9600 (초기값)","en":"9600 (default)"},{"value":2,"ko":"14400","en":"14400"},{"value":3,"ko":"19200","en":"19200"},{"value":4,"ko":"38400","en":"38400"},{"value":5,"ko":"57600","en":"57600"}],"ref":"p.103 (PDF 104) G.COM"},{"table":"holding-registers","address":602,"manualAddress":"D-register 602 (025Ah) / Address 603","type":"u16","name":{"ko":"패리티","en":"Parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음 (초기값)","en":"None (default)"},{"value":1,"ko":"짝수","en":"Even"},{"value":2,"ko":"홀수","en":"Odd"}],"ref":"p.103 (PDF 104) G.COM"},{"table":"holding-registers","address":605,"manualAddress":"D-register 605 (025Dh) / Address 606","type":"u16","name":{"ko":"국번(기기 주소)","en":"Device address"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":99},"ref":"p.103 (PDF 104) G.COM"},{"table":"holding-registers","address":606,"manualAddress":"D-register 606 (025Eh) / Address 607","type":"u16","name":{"ko":"응답 지연 시간","en":"Response delay"},"unit":"ms","access":"rw","fc":[3,6,16],"range":{"min":0,"max":99},"description":{"ko":"단위 ms 는 p.10 통신 파라미터.","en":"Unit (ms) from p.10 communication parameters."},"ref":"p.103 (PDF 104) G.COM"},{"table":"holding-registers","address":701,"manualAddress":"D-register 701 (02BDh) / Address 702","type":"u16","name":{"ko":"전원 ON 후 동작","en":"Power-on operation"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"정지","en":"Stop"},{"value":1,"ko":"운전 (초기값)","en":"Run (default)"}],"ref":"p.105 (PDF 106) G.SET"},{"table":"holding-registers","address":900,"manualAddress":"D-register 900 (0384h) / Address 901","type":"u16","name":{"ko":"입력 종류","en":"Input type (INP)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":34},"description":{"ko":"초기 1(K0). 번호별 센서는 제품 사용설명서의 입력 종류 표 참조(통신 설명서엔 표 없음).","en":"Default 1 (K0). Sensor list per code is in the product manual (not in the comm manual)."},"ref":"p.107 (PDF 108) G.IN"},{"table":"holding-registers","address":901,"manualAddress":"D-register 901 (0385h) / Address 902","type":"u16","name":{"ko":"단위 선택","en":"Unit select"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃ (초기값)","en":"°C (default)"},{"value":1,"ko":"℉","en":"°F"},{"value":2,"ko":"%","en":"%"},{"value":3,"ko":"무단위","en":"none"}],"description":{"ko":"TC·RTD 입력은 ℃·℉ 만.","en":"TC/RTD inputs: °C/°F only."},"ref":"p.107 (PDF 108) G.IN"},{"table":"holding-registers","address":904,"manualAddress":"D-register 904 (0388h) / Address 905","type":"u16","name":{"ko":"소수점 위치 선택","en":"Decimal point select (DP-P)"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":3},"description":{"ko":"TC·RTD 는 0~1 이고 읽기만 가능, DC 전류·전압 입력은 0~3. 초기 1.","en":"TC/RTD: 0-1, read-only; DC current/voltage: 0-3. Default 1."},"ref":"p.107 (PDF 108) G.IN"},{"table":"holding-registers","address":909,"manualAddress":"D-register 909 (038Dh) / Address 910","type":"s16","name":{"ko":"PV 보정(바이어스)","en":"PV bias"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점은 DP-P. EUS -100.0~100.0 %.","en":"Decimals per DP-P. EUS -100.0 to 100.0 %."},"ref":"p.108 (PDF 109) G.IN"}],"notes":[{"ko":"온도 계열 값(PV·SV·경보값·비례대·바이어스 등)은 부호 있는 16비트 정수에 DP-P 자릿수만큼 소수점을 붙여 읽는다(p.30 예: 0xFC18 = -1000 → -100.0). DP-P 는 입력 종류에 따라 달라지므로 scale 을 고정하지 않았다.","en":"Temperature-type values are signed 16-bit integers with DP-P decimals (p.30 example: 0xFC18 = -1000 → -100.0). DP-P depends on input type, so no fixed scale."},{"ko":"LOCK(D703) 설명의 «32~34, 703 번지» 는 Address 열(1 기준) 번호로 보인다 — 통신선 주소로는 31~33, 702.","en":"LOCK (D703) text cites '32-34, 703', which match the 1-based Address column (wire 31-33, 702)."},{"ko":"I 레지스터(p.111)는 PC LINK 명령용이며 Modbus 함수 코드(03/06/08/16)는 D 레지스터만 다룬다.","en":"I-registers (p.111) are for PC LINK commands; Modbus FCs (03/06/08/16) cover D-registers only."}],"sources":[{"title":"통신 설명서 VX Series","publisher":"HANYOUNG NUX","edition":{"ko":"December 18, 2024","en":"December 18, 2024"},"url":"https://www.hanyoungnux.co.kr/data/main.php?down=1121(VX_comm_user_241218).pdf&file_name=VX_comm_user_241218.pdf","pages":{"ko":"p.10 통신 파라미터, p.25~38 MODBUS, p.90~114 통신 맵 (PDF 쪽 = 인쇄 쪽 + 1)","en":"p.10 communication parameters, pp.25-38 MODBUS, pp.90-114 communication map (PDF page = printed page + 1)"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"ls-electric/gimac1000","manufacturer":{"ko":"LS ELECTRIC","en":"LS ELECTRIC"},"model":"GIMAC1000","kind":"power-meter","title":{"ko":"LS ELECTRIC GIMAC1000 디지털 전력 계측장치","en":"LS ELECTRIC GIMAC1000 digital power measuring device"},"summary":{"ko":"계측값은 input register(FC04)에 Float32(실제 단위), 장치 정보는 holding register(FC03) 문자열, 리셋은 coil(FC05). 32비트 워드 순서는 Swap 설정에 따라 바뀐다.","en":"Measurements in input registers (FC04) as Float32 engineering units, device info as strings in holding registers (FC03), resets as coils (FC05). 32-bit word order depends on the Swap setting."},"protocols":["rtu","tcp"],"comm":{"baud":38400,"bauds":[9600,19200,38400],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"maxRegisters":124,"addressing":"plc","notes":[{"ko":"맵은 REGISTER(30001·40001 꼴)와 ADDRESS(0 기준) 칸을 함께 적는다 — address 는 ADDRESS 칸 그대로 (map p.1, p.6). 예: 30001 ↔ 0, 40038 ↔ 37, coil 1 ↔ 0 (map p.15 프레임 예).","en":"Map gives both REGISTER (30001/40001 style) and ADDRESS (0-based) columns; address here is the ADDRESS column (map p.1, p.6). E.g. 30001 ↔ 0, 40038 ↔ 37, coil 1 ↔ 0 (map p.15 frame examples)."},{"ko":"출하값: 국번 1, 38400 bps (map p.6 41008·41009, 사용설명서 p.33 Table6). 패리티 없음만 지원, 1 start + 8 data + 1 stop (map p.12).","en":"Defaults: unit 1, 38400 bps (map p.6 41008/41009, user manual p.33 Table 6). Only no parity supported, 1 start + 8 data + 1 stop (map p.12)."},{"ko":"워드 순서: Swap NO = 상위 워드 먼저(ABCD, 100.0 → 42 C8 00 00), Swap YES = 워드 바꿈(CDAB, 00 00 42 C8) (사용설명서 p.42). 출하 Swap 값은 문서끼리 다르다 — 맵 p.6(41009)은 1(NO), 사용설명서 p.33·p.42 는 YES(On). 그래서 order 를 적지 않았다 — 31008 상위 바이트(1=끔, 2=켬)를 읽거나 장치 'S' 설정으로 확인.","en":"Word order: Swap NO = high word first (ABCD, 100.0 → 42 C8 00 00); Swap YES = word-swapped (CDAB, 00 00 42 C8) (user manual p.42). Factory default conflicts: map p.6 (41009) says 1 (NO), user manual p.33/p.42 says YES (On). So order is left out — read 31008 high byte (1 = off, 2 = on) or check the 'S' setting."},{"ko":"Ethernet(TCP)은 별도 'TCP SWAP' 설정(출하 On)이 있다 (사용설명서 p.33, 맵 p.6 41022). TCP 포트 번호는 문서에 없다.","en":"Ethernet (TCP) has a separate 'TCP SWAP' setting (default On) (user manual p.33, map p.6 41022). TCP port number is not stated."},{"ko":"한 번에 최대 124 레지스터(03h·04h), 연속 주소에서만 (map p.16).","en":"Up to 124 registers per read (03h/04h), contiguous only (map p.16)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"1","type":"bit","name":{"ko":"유효전력량 리셋","en":"Wh reset"},"access":"w","fc":[5],"description":{"ko":"ON(0xFF00) 만 쓸 수 있음 (F001)","en":"Only ON (0xFF00) accepted (F001)"},"ref":"map p.1"},{"table":"coils","address":2000,"manualAddress":"2001","type":"bit","name":{"ko":"전체 데이터 리셋","en":"All data reset"},"access":"w","fc":[5],"description":{"ko":"ON(0xFF00) 만 쓸 수 있음 (F001)","en":"Only ON (0xFF00) accepted (F001)"},"ref":"map p.1"},{"table":"input-registers","address":0,"manualAddress":"30001","type":"f32","name":{"ko":"평균 전압","en":"Average voltage"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":2,"manualAddress":"30003","type":"f32","name":{"ko":"평균 전류","en":"Average current"},"unit":"A","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":4,"manualAddress":"30005","type":"f32","name":{"ko":"A상 전류","en":"Phase A current"},"unit":"A","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":6,"manualAddress":"30007","type":"f32","name":{"ko":"B상 전류","en":"Phase B current"},"unit":"A","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":8,"manualAddress":"30009","type":"f32","name":{"ko":"C상 전류","en":"Phase C current"},"unit":"A","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":10,"manualAddress":"30011","type":"f32","name":{"ko":"A-N 상전압","en":"Voltage A-N"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":12,"manualAddress":"30013","type":"f32","name":{"ko":"B-N 상전압","en":"Voltage B-N"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":14,"manualAddress":"30015","type":"f32","name":{"ko":"C-N 상전압","en":"Voltage C-N"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":16,"manualAddress":"30017","type":"f32","name":{"ko":"A-B 선간전압","en":"Voltage A-B"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":18,"manualAddress":"30019","type":"f32","name":{"ko":"B-C 선간전압","en":"Voltage B-C"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":20,"manualAddress":"30021","type":"f32","name":{"ko":"C-A 선간전압","en":"Voltage C-A"},"unit":"V","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":22,"manualAddress":"30023","type":"f32","name":{"ko":"역률","en":"Power factor"},"access":"r","fc":[4],"description":{"ko":"음수 = 진상(Lead)","en":"Negative means lead"},"ref":"map p.1"},{"table":"input-registers","address":24,"manualAddress":"30025","type":"f32","name":{"ko":"총 유효전력","en":"Total active power"},"unit":"W","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":26,"manualAddress":"30027","type":"f32","name":{"ko":"총 무효전력","en":"Total reactive power"},"unit":"Var","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":28,"manualAddress":"30029","type":"f32","name":{"ko":"총 피상전력","en":"Total apparent power"},"unit":"VA","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":30,"manualAddress":"30031","type":"f32","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[4],"ref":"map p.1"},{"table":"input-registers","address":32,"manualAddress":"30033","type":"f32","name":{"ko":"유효전력량","en":"Active energy"},"unit":"Wh","access":"r","fc":[4],"description":{"ko":"Giga 카운터(30531)를 더해 읽어야 한다고만 적혀 있음 — 더하는 배율은 매뉴얼에 없음","en":"Manual says to add the Giga counter (30531); its weight is not stated"},"ref":"map p.1"},{"table":"input-registers","address":34,"manualAddress":"30035","type":"f32","name":{"ko":"무효전력량","en":"Reactive energy"},"unit":"Varh","access":"r","fc":[4],"description":{"ko":"Giga 카운터(30532)를 더해 읽음 — 배율 명시 없음","en":"Add Giga counter (30532); weight not stated"},"ref":"map p.1"},{"table":"input-registers","address":36,"manualAddress":"30037","type":"f32","name":{"ko":"피상전력량","en":"Apparent energy"},"unit":"VAh","access":"r","fc":[4],"description":{"ko":"Giga 카운터(30533)를 더해 읽음 — 배율 명시 없음","en":"Add Giga counter (30533); weight not stated"},"ref":"map p.1"},{"table":"input-registers","address":44,"manualAddress":"30045","type":"f32","name":{"ko":"역방향 유효전력량","en":"Reverse active energy"},"unit":"Wh","access":"r","fc":[4],"description":{"ko":"EX 모델만. Giga 카운터(30534)를 더해 읽음","en":"EX model only. Add Giga counter (30534)"},"ref":"map p.1"},{"table":"input-registers","address":48,"manualAddress":"30049","type":"f32","name":{"ko":"A상 유효전력","en":"Phase A active power"},"unit":"W","access":"r","fc":[4],"description":{"ko":"EX 모델만 지원","en":"EX model only"},"ref":"map p.1"},{"table":"input-registers","address":50,"manualAddress":"30051","type":"f32","name":{"ko":"B상 유효전력","en":"Phase B active power"},"unit":"W","access":"r","fc":[4],"description":{"ko":"EX 모델만 지원","en":"EX model only"},"ref":"map p.1"},{"table":"input-registers","address":52,"manualAddress":"30053","type":"f32","name":{"ko":"C상 유효전력","en":"Phase C active power"},"unit":"W","access":"r","fc":[4],"description":{"ko":"EX 모델만 지원","en":"EX model only"},"ref":"map p.1"},{"table":"input-registers","address":78,"manualAddress":"30079","type":"f32","name":{"ko":"A상 역률","en":"Phase A power factor"},"access":"r","fc":[4],"description":{"ko":"EX 모델만. 음수 = 진상","en":"EX model only. Negative = lead"},"ref":"map p.2"},{"table":"input-registers","address":80,"manualAddress":"30081","type":"f32","name":{"ko":"B상 역률","en":"Phase B power factor"},"access":"r","fc":[4],"description":{"ko":"EX 모델만. 음수 = 진상","en":"EX model only. Negative = lead"},"ref":"map p.2"},{"table":"input-registers","address":82,"manualAddress":"30083","type":"f32","name":{"ko":"C상 역률","en":"Phase C power factor"},"access":"r","fc":[4],"description":{"ko":"EX 모델만. 음수 = 진상","en":"EX model only. Negative = lead"},"ref":"map p.2"},{"table":"input-registers","address":110,"manualAddress":"30111","type":"f32","name":{"ko":"전력 디맨드","en":"Power demand"},"unit":"W","access":"r","fc":[4],"description":{"ko":"EX 모델만 지원","en":"EX model only"},"ref":"map p.2"},{"table":"input-registers","address":530,"manualAddress":"30531","type":"u16","name":{"ko":"유효전력량 Giga 카운터","en":"Active energy Giga counter"},"access":"r","fc":[4],"description":{"ko":"범위 0-999","en":"Range 0-999"},"ref":"map p.5"},{"table":"input-registers","address":531,"manualAddress":"30532","type":"u16","name":{"ko":"무효전력량 Giga 카운터","en":"Reactive energy Giga counter"},"access":"r","fc":[4],"description":{"ko":"범위 0-999","en":"Range 0-999"},"ref":"map p.6"},{"table":"input-registers","address":532,"manualAddress":"30533","type":"u16","name":{"ko":"피상전력량 Giga 카운터","en":"Apparent energy Giga counter"},"access":"r","fc":[4],"description":{"ko":"범위 0-999","en":"Range 0-999"},"ref":"map p.6"},{"table":"input-registers","address":1000,"manualAddress":"31001","type":"u16","name":{"ko":"결선 방식","en":"Wiring connection"},"access":"r","fc":[4],"values":[{"value":1,"ko":"1P2W","en":"1P2W"},{"value":2,"ko":"1P3W","en":"1P3W"},{"value":3,"ko":"3P3W 오픈 델타","en":"3P3W open delta"},{"value":4,"ko":"3P3W Y","en":"3P3W Y"},{"value":5,"ko":"3P4W","en":"3P4W"}],"ref":"map p.6, p.7 F219"},{"table":"input-registers","address":1007,"manualAddress":"31008","type":"u16","name":{"ko":"RS-485 속도·Swap 설정","en":"RS-485 speed / swap"},"access":"r","fc":[4],"description":{"ko":"상위 바이트 = Swap(1 사용 안 함, 2 사용), 하위 바이트 = 속도(1 9600, 2 19200, 3 38400). Swap 이 켜져 있으면 32비트 값의 워드 순서가 바뀐다","en":"High byte = swap (1 disabled, 2 enabled); low byte = baud (1 9600, 2 19200, 3 38400). With swap enabled 32-bit words are exchanged"},"ref":"map p.6, p.7 F218"},{"table":"holding-registers","address":0,"manualAddress":"40001","type":"string","len":32,"name":{"ko":"제조사 이름","en":"Manufacturer name"},"access":"r","fc":[3],"description":{"ko":"\"LSELECTRIC\". 40000 번대는 Swap 적용 안 됨","en":"\"LSELECTRIC\". Swap not applied to 4xxxx"},"ref":"map p.6"},{"table":"holding-registers","address":37,"manualAddress":"40038","type":"string","len":32,"name":{"ko":"제품 이름","en":"Product name"},"access":"r","fc":[3],"description":{"ko":"\"GIMAC1000\"","en":"\"GIMAC1000\""},"ref":"map p.6"},{"table":"holding-registers","address":75,"manualAddress":"40076","type":"string","len":10,"name":{"ko":"소프트웨어 버전","en":"Software version"},"access":"r","fc":[3],"description":{"ko":"예 \"01.00.00\"","en":"e.g. \"01.00.00\""},"ref":"map p.6"}],"notes":[{"ko":"모든 계측값은 PT/CT 비가 반영된 실제 단위의 Float32(F004) — 단위는 W·var·VA·Wh(k 아님)에 주의.","en":"Measurements are Float32 (F004) in engineering units after PT/CT ratio; note units are W, var, VA, Wh (not k-)."},{"ko":"상별 전력·상별 역률·디맨드 등 일부는 EX 모델만 지원 (map Remark 칸).","en":"Per-phase power/PF, demand etc. are EX model only (map Remark column)."},{"ko":"맵에 함수 코드 칸은 없다 — 표 종류(3xxxx=FC04, 4xxxx=FC03, F001 리셋=FC05 ON 만)는 map p.15-16 프레임 예와 F001 설명(p.7)으로 판단했다.","en":"The map has no function-code column; FC per table (3xxxx = FC04, 4xxxx = FC03, F001 resets = FC05 ON only) follows the frame examples (map p.15-16) and F001 (p.7)."},{"ko":"map p.6 의 31001-31010 과 41001-41023 설정값은 R 로만 표기 — 통신으로 설정을 쓰는 방법은 이 맵에 없다.","en":"Settings at 31001-31010 and 41001-41023 are marked R only (map p.6); writing settings over Modbus is not described."}],"sources":[{"title":"GIMAC1000 MODBUS MAP","publisher":"LS ELECTRIC","edition":{"ko":"Tech Data EN 2024-02 (파일명 [GIMAC1000] Modbus Map_Tech Data_EN_202402.pdf, 등록 2024-04-02)","en":"Tech Data EN 2024-02 (file name [GIMAC1000] Modbus Map_Tech Data_EN_202402.pdf, posted 2024-04-02)"},"url":"https://www.ls-electric.com/ko/cat/HPDT/%5BGIMAC1000%5D%20Modbus%20Map_Tech%20Data_EN_202402.pdf","pages":{"ko":"PDF p.1-8 맵·형식, p.12-16 RTU, p.17-21 TCP (인쇄 쪽 번호 없음)","en":"PDF pp.1-8 map and formats, pp.12-16 RTU, pp.17-21 TCP (no printed page numbers)"},"checked":"2026-10-19"},{"title":"Digital Power Measuring Device GIMAC1000 User's Manual","publisher":"LS ELECTRIC","edition":{"ko":"EN 2023-03 (파일명 [GIMAC1000] User Manual EN_Manual_EN_202303.pdf)","en":"EN 2023-03 (file name [GIMAC1000] User Manual EN_Manual_EN_202303.pdf)"},"url":"https://www.ls-electric.com/ko/cat/HPDT/%5BGIMAC1000%5D%20User%20Manual%20EN_Manual_EN_202303.pdf","pages":{"ko":"p.33 Table6 설정 메뉴(출하값), p.41-42 통신 속도·SWAP","en":"p.33 Table 6 setup menu (factory values), pp.41-42 baud rate and SWAP"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"ls-electric/g100","manufacturer":{"ko":"LS일렉트릭","en":"LS ELECTRIC"},"model":"LSLV-G100","models":["G100","G100C"],"kind":"inverter","title":{"ko":"LS일렉트릭 G100 인버터 (내장 RS-485)","en":"LS ELECTRIC G100 AC drive (built-in RS-485)"},"summary":{"ko":"내장 RS-485 Modbus-RTU. M100·S100·H100·iS7·S300 호환 공통 영역(0h0000~)과 G100 확장 공통 영역(0h0300~)","en":"Built-in RS-485 Modbus-RTU. Compatible common area (0h0000-) and G100 expansion common area (0h0300-)"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,250],"addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼 Modbus-RTU 통신 예(p.255, PDF 269)에서 통신 주소 0x1246 에 쓸 때 프레임 시작 주소를 0x1245(«Starting Address -1»)로 보낸다. 그래서 address = 매뉴얼 주소 - 1 로 적었다. 예는 파라미터 영역 하나뿐이고, 이 규칙대로면 0h0000(인버터 모델)은 -1 이 되어 표현할 수 없어 뺐다. 공통 영역에도 같은 규칙이 맞는지 실기로 확인 권장.","en":"Addressing: the manual's Modbus-RTU example (p.255, PDF 269) sends starting address 0x1245 for comm address 0x1246 ('Starting Address -1'), so address = manual address - 1. The example is from the parameter area only; under this rule 0h0000 (model) maps to -1 and is omitted. Verify on hardware for the common area."},{"ko":"초기값: CM.01 국번 1(1~250), CM.02 0 Modbus-RTU, CM.03 3=9600bps, CM.04 0=D8/PN/S1(8N1); CM.04 는 0·2·3(8N1·8E1·8O1). p.241~242 (PDF 255~256).","en":"Defaults: CM.01 ID 1 (1-250), CM.02 0 Modbus-RTU, CM.03 3 = 9600 bps, CM.04 0 = D8/PN/S1; CM.04 offers 0/2/3 (8N1/8E1/8O1). p.241-242 (PDF 255-256)."},{"ko":"CM.03 설정 6 은 «56Kbps» 로, 규격표(PDF 252)에는 57,600bps 로 적혀 있어 bauds 에서 뺐다.","en":"CM.03 setting 6 reads '56Kbps' while the spec table (PDF 252) lists 57,600 bps, so it is left out of bauds."},{"ko":"함수 코드 03·04·06·16 지원 (p.253~254, PDF 267~268).","en":"Function codes 03, 04, 06, 16 supported (p.253-254, PDF 267-268)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"0h0001","type":"u16","name":{"ko":"인버터 용량","en":"Inverter capacity"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"0.75kW","en":"0.75kW"},{"value":1,"ko":"1.5kW","en":"1.5kW"},{"value":2,"ko":"2.2kW","en":"2.2kW"},{"value":4,"ko":"5.5kW","en":"5.5kW"},{"value":5,"ko":"7.5kW","en":"7.5kW"},{"value":6,"ko":"11kW","en":"11kW"},{"value":7,"ko":"15kW","en":"15kW"},{"value":8,"ko":"18.5kW","en":"18.5kW"},{"value":9,"ko":"22kW","en":"22kW"},{"value":256,"ko":"0.4kW","en":"0.4kW"},{"value":259,"ko":"4.0kW","en":"4.0kW"}],"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":1,"manualAddress":"0h0002","type":"u16","name":{"ko":"입력 전압 등급","en":"Input voltage class"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"200V 급","en":"200 V class"},{"value":1,"ko":"400V 급","en":"400 V class"}],"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":2,"manualAddress":"0h0003","type":"u16","name":{"ko":"S/W 버전","en":"S/W version"},"access":"r","fc":[3,4],"description":{"ko":"16진: 0x0100 = 버전 1.00","en":"Hex: 0x0100 = version 1.00"},"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":4,"manualAddress":"0h0005","type":"u16","name":{"ko":"주파수 지령","en":"Frequency command"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":5,"manualAddress":"0h0006","type":"u16","name":{"ko":"운전 지령","en":"Operation command"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"정지(S)","en":"Stop (S)"},{"bit":1,"ko":"정방향 운전(F)","en":"Forward run (F)"},{"bit":2,"ko":"역방향 운전(R)","en":"Reverse run (R)"},{"bit":3,"ko":"트립 리셋","en":"Trip reset"},{"bit":4,"ko":"프리런 정지","en":"Free-run stop"}],"description":{"ko":"B5~B15 는 읽기 전용: B6~B8 운전 지령 소스(0 키패드, 1 Fx/Rx-1, 2 Fx/Rx-2, 3 내장 485, 4 통신 옵션), B9~B14 주파수 지령 소스(0 키패드 주파수, 1 키패드 토크, 2~16 단자대 다단속, 17 Up, 18 Down, 19 STEADY, 22 V1, 23 V2, 24 V0, 25 I2, 27 내장 485, 28 통신 옵션, 30 JOG, 31 PID)","en":"B5-B15 read-only: B6-B8 run command source (0 keypad, 1 Fx/Rx-1, 2 Fx/Rx-2, 3 built-in 485, 4 comm option), B9-B14 frequency source (0 keypad freq, 1 keypad torque, 2-16 multi-step, 17 up, 18 down, 19 steady, 22 V1, 23 V2, 24 V0, 25 I2, 27 built-in 485, 28 comm option, 30 jog, 31 PID)"},"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":6,"manualAddress":"0h0007","type":"u16","name":{"ko":"가속 시간","en":"Acceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":7,"manualAddress":"0h0008","type":"u16","name":{"ko":"감속 시간","en":"Deceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.259 (PDF 273)"},{"table":"holding-registers","address":8,"manualAddress":"0h0009","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":9,"manualAddress":"0h000A","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":10,"manualAddress":"0h000B","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":11,"manualAddress":"0h000C","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":12,"manualAddress":"0h000D","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":13,"manualAddress":"0h000E","type":"u16","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"정지","en":"Stopped"},{"bit":1,"ko":"정방향 운전 중","en":"Running forward"},{"bit":2,"ko":"역방향 운전 중","en":"Running reverse"},{"bit":3,"ko":"고장 트립","en":"Fault trip"},{"bit":4,"ko":"가속 중","en":"Accelerating"},{"bit":5,"ko":"감속 중","en":"Decelerating"},{"bit":6,"ko":"속도 도달","en":"Speed reached"},{"bit":7,"ko":"직류 제동","en":"DC braking"},{"bit":8,"ko":"정지 중","en":"Drive stopping"},{"bit":9,"ko":"조그 모드","en":"Jog mode"},{"bit":10,"ko":"브레이크 개방 신호","en":"Brake release signal"},{"bit":11,"ko":"정방향 운전 지령","en":"Forward run command"},{"bit":12,"ko":"역방향 운전 지령","en":"Reverse run command"},{"bit":13,"ko":"운전 지령이 통신(내장·옵션)","en":"Run command source is communication"},{"bit":14,"ko":"주파수 지령이 통신(내장·옵션)","en":"Frequency command source is communication"}],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":14,"manualAddress":"0h000F","type":"u16","name":{"ko":"고장 트립 정보","en":"Fault trip information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"래치형 트립","en":"Latch type trip"},{"bit":3,"ko":"레벨형 트립","en":"Level type trip"},{"bit":10,"ko":"H/W 진단 트립","en":"H/W diagnosis trip"}],"ref":"p.260 (PDF 274)"},{"table":"holding-registers","address":15,"manualAddress":"0h0010","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"P1","en":"P1"},{"bit":1,"ko":"P2","en":"P2"},{"bit":2,"ko":"P3","en":"P3"},{"bit":3,"ko":"P4","en":"P4"},{"bit":4,"ko":"P5","en":"P5"},{"bit":5,"ko":"P6","en":"P6"},{"bit":6,"ko":"P7","en":"P7"},{"bit":7,"ko":"P8","en":"P8"}],"ref":"p.261 (PDF 275)"},{"table":"holding-registers","address":16,"manualAddress":"0h0011","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"릴레이 1","en":"Relay 1"},{"bit":1,"ko":"릴레이 2","en":"Relay 2"}],"ref":"p.261 (PDF 275)"},{"table":"holding-registers","address":768,"manualAddress":"0h0301","type":"u16","name":{"ko":"인버터 용량(확장)","en":"Inverter capacity (ext.)"},"access":"r","fc":[3,4],"values":[{"value":6400,"ko":"0.4kW","en":"0.4kW"},{"value":12800,"ko":"0.75kW","en":"0.75kW"},{"value":16405,"ko":"1.5kW","en":"1.5kW"},{"value":16418,"ko":"2.2kW","en":"2.2kW"},{"value":16448,"ko":"4.0kW","en":"4.0kW"},{"value":16469,"ko":"5.5kW","en":"5.5kW"},{"value":16501,"ko":"7.5kW","en":"7.5kW"},{"value":16560,"ko":"11kW","en":"11kW"},{"value":16624,"ko":"15kW","en":"15kW"},{"value":16677,"ko":"18.5kW","en":"18.5kW"},{"value":16736,"ko":"22kW","en":"22kW"}],"ref":"p.262 (PDF 276)"},{"table":"holding-registers","address":772,"manualAddress":"0h0305","type":"u16","name":{"ko":"인버터 운전 상태","en":"Inverter operation state"},"access":"r","fc":[3,4],"description":{"ko":"B15~B12: 0 정상, 4 경고, 8 고장 / B7~B4: 1 속도 탐색, 2 가속, 3 정속, 4 감속, 5 감속 정지, 6 H/W OCS, 7 S/W OCS, 8 드웰 / B3~B0: 0 정지, 1 정방향, 2 역방향, 3 DC 운전","en":"B15-B12: 0 normal, 4 warning, 8 fault / B7-B4: 1 speed search, 2 accel, 3 steady, 4 decel, 5 decel to stop, 6 H/W OCS, 7 S/W OCS, 8 dwell / B3-B0: 0 stop, 1 forward, 2 reverse, 3 DC operation"},"ref":"p.262 (PDF 276)"},{"table":"holding-registers","address":773,"manualAddress":"0h0306","type":"u16","name":{"ko":"운전·주파수 지령 소스","en":"Run / frequency command source"},"access":"r","fc":[3,4],"description":{"ko":"B15~B8 운전 지령: 0 키패드, 1 통신 옵션, 3 내장 485, 4 단자대 / B7~B0 주파수 지령: 0 키패드 속도, 1 키패드 토크, 2~4 Up/Down, 5 V1, 6 V2, 7 V0, 8 I2, 10 내장 485, 11 통신 옵션, 13 Jog, 14 PID, 25~39 다단속","en":"B15-B8 run source: 0 keypad, 1 comm option, 3 built-in 485, 4 terminal / B7-B0 freq source: 0 keypad speed, 1 keypad torque, 2-4 up/down, 5 V1, 6 V2, 7 V0, 8 I2, 10 built-in 485, 11 comm option, 13 jog, 14 PID, 25-39 multi-step"},"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":774,"manualAddress":"0h0307","type":"u16","name":{"ko":"Safety A 단자","en":"Safety A terminal"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"SA-SC 단락","en":"SA-SC shorted"},{"value":1,"ko":"SA-SC 개방","en":"SA-SC open"}],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":775,"manualAddress":"0h0308","type":"u16","name":{"ko":"Safety B 단자","en":"Safety B terminal"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"SB-SC 단락","en":"SB-SC shorted"},{"value":1,"ko":"SB-SC 개방","en":"SB-SC open"}],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":783,"manualAddress":"0h0310","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":784,"manualAddress":"0h0311","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":787,"manualAddress":"0h0314","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":788,"manualAddress":"0h0315","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":789,"manualAddress":"0h0316","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":790,"manualAddress":"0h0317","type":"u16","name":{"ko":"출력 토크","en":"Output torque"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.263 (PDF 277)"},{"table":"holding-registers","address":812,"manualAddress":"0h032D","type":"u16","name":{"ko":"인버터 모듈 온도","en":"Inverter module temperature"},"unit":"℃","access":"r","fc":[3,4],"ref":"p.265 (PDF 279)"},{"table":"holding-registers","address":813,"manualAddress":"0h032E","type":"u16","name":{"ko":"소비 전력량(kWh)","en":"Energy consumption (kWh)"},"unit":"kWh","scale":0.1,"access":"r","fc":[3,4],"ref":"p.265 (PDF 279)"},{"table":"holding-registers","address":815,"manualAddress":"0h0330","type":"u16","name":{"ko":"래치형 트립 정보 1","en":"Latch type trip info 1"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"과부하 트립","en":"Overload trip"},{"bit":1,"ko":"저부하 트립","en":"Underload trip"},{"bit":2,"ko":"인버터 과부하 트립","en":"Inverter overload trip"},{"bit":3,"ko":"전자 서멀 트립","en":"E-Thermal trip"},{"bit":4,"ko":"지락 트립","en":"Ground fault trip"},{"bit":5,"ko":"출력 결상 트립","en":"Output open-phase trip"},{"bit":6,"ko":"입력 결상 트립","en":"Input open-phase trip"},{"bit":9,"ko":"NTC 트립","en":"NTC trip"},{"bit":10,"ko":"과전류 트립","en":"Overcurrent trip"},{"bit":11,"ko":"과전압 트립","en":"Overvoltage trip"},{"bit":12,"ko":"외부 트립","en":"External trip"},{"bit":13,"ko":"암 단락","en":"Arm short"},{"bit":14,"ko":"과열 트립","en":"Over heat trip"},{"bit":15,"ko":"퓨즈 단선 트립","en":"Fuse open trip"}],"ref":"p.265 (PDF 279)"},{"table":"holding-registers","address":816,"manualAddress":"0h0331","type":"u16","name":{"ko":"래치형 트립 정보 2","en":"Latch type trip info 2"},"access":"r","fc":[3,4],"bits":[{"bit":2,"ko":"PTC 트립","en":"PTC trip"},{"bit":3,"ko":"팬 트립","en":"Fan trip"},{"bit":6,"ko":"Pre PID 실패","en":"Pre PID fail"},{"bit":7,"ko":"기본 I/O 접촉 불량","en":"Bad contact at basic I/O board"},{"bit":8,"ko":"외부 브레이크 트립","en":"External brake trip"},{"bit":9,"ko":"모터 미연결 트립","en":"No motor trip"},{"bit":10,"ko":"옵션 카드 이상","en":"Bad option card"},{"bit":14,"ko":"과열 예보 트립","en":"Pre over heat trip"}],"ref":"p.265 (PDF 279)"},{"table":"holding-registers","address":817,"manualAddress":"0h0332","type":"u16","name":{"ko":"레벨형 트립 정보","en":"Level type trip info"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"BX","en":"BX"},{"bit":1,"ko":"저전압 트립","en":"Low voltage trip"},{"bit":2,"ko":"지령 상실","en":"Lost command"},{"bit":3,"ko":"키패드 지령 상실","en":"Keypad lost command"}],"ref":"p.266 (PDF 280)"},{"table":"holding-registers","address":819,"manualAddress":"0h0334","type":"u16","name":{"ko":"경고 정보","en":"Warning information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"과부하","en":"Overload"},{"bit":1,"ko":"저부하","en":"Underload"},{"bit":2,"ko":"인버터 과부하","en":"Inverter overload"},{"bit":3,"ko":"지령 상실","en":"Lost command"},{"bit":4,"ko":"팬 운전 중","en":"Fan running"},{"bit":5,"ko":"DB","en":"DB"},{"bit":6,"ko":"엔코더 설치 오류","en":"Wrong encoder installation"},{"bit":7,"ko":"엔코더 단선","en":"Encoder disconnection"},{"bit":8,"ko":"키패드 상실","en":"Keypad lost"},{"bit":9,"ko":"오토튜닝 실패","en":"Auto tuning failed"},{"bit":12,"ko":"화재 모드","en":"Fire mode"},{"bit":14,"ko":"파라미터 쓰기 실패","en":"Parameter write fail"},{"bit":15,"ko":"과열 예보","en":"Pre overheat"}],"ref":"p.266 (PDF 280)"},{"table":"holding-registers","address":895,"manualAddress":"0h0380","type":"u16","name":{"ko":"주파수 지령(확장)","en":"Frequency command (ext.)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.267 (PDF 281)"},{"table":"holding-registers","address":897,"manualAddress":"0h0382","type":"u16","name":{"ko":"운전 지령(확장)","en":"Operation command (ext.)"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"0 정지 / 1 운전","en":"0 stop / 1 run"},{"bit":1,"ko":"0 역방향 / 1 정방향","en":"0 reverse / 1 forward"},{"bit":2,"ko":"트립 리셋(0→1)","en":"Trip reset (0->1)"},{"bit":3,"ko":"프리런 정지(0→1)","en":"Free-run stop (0->1)"}],"description":{"ko":"정방향 운전 0x0003, 역방향 운전 0x0001 (p.268)","en":"Forward run 0x0003, reverse run 0x0001 (p.268)"},"ref":"p.267 (PDF 281)"},{"table":"holding-registers","address":898,"manualAddress":"0h0383","type":"u16","name":{"ko":"가속 시간(확장)","en":"Acceleration time (ext.)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.268 (PDF 282)"},{"table":"holding-registers","address":899,"manualAddress":"0h0384","type":"u16","name":{"ko":"감속 시간(확장)","en":"Deceleration time (ext.)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.268 (PDF 282)"},{"table":"holding-registers","address":991,"manualAddress":"0h03E0","type":"u16","name":{"ko":"파라미터 저장","en":"Save parameters"},"access":"rw","fc":[3,4,6,16],"values":[{"value":0,"ko":"아니오","en":"No"},{"value":1,"ko":"예","en":"Yes"}],"description":{"ko":"운전 중 변경 불가","en":"Not changeable during run"},"ref":"p.269 (PDF 283)"}],"notes":[{"ko":"통신으로 운전·주파수를 주려면 drv=3(Int 485)·Frq=6(Int 485) (p.242).","en":"Set drv = 3 (Int 485) and Frq = 6 (Int 485) to command over RS-485 (p.242)."},{"ko":"0h0380·0h0005 로 준 주파수는 파라미터 저장으로도 남지 않는다 (p.269).","en":"Frequency written to 0h0380/0h0005 is not retained by parameter save (p.269)."},{"ko":"0h000E 운전 상태의 R/W 칸은 매뉴얼에 «-» 로 비어 있다 — 상태 값이라 r 로 두었다.","en":"The R/W cell of 0h000E is '-' in the manual; set to r as it is a status word."},{"ko":"호환 공통 영역 0h0001 용량 표에 3.7kW(값 3) 는 없다(매뉴얼 그대로).","en":"The 0h0001 capacity table has no 3.7 kW entry (as in the manual)."}],"sources":[{"title":"G100(C) User Manual (G100(C)_User Manual_EN_V4.04_261001.pdf) — LSLV-G100","publisher":"LS ELECTRIC","edition":{"ko":"4th Edition (Revision History 2024.08, p.398); 파일 V4.04, 2026-10-01","en":"4th Edition (Revision History 2024.08, p.398); file V4.04, 2026-10-01"},"url":"https://sftpssqblobcdn.blob.core.windows.net/prod/largefile/document/17908426583480/G100%28C%29_User%20Manual_EN_V4.04_261001.pdf","pages":{"ko":"7장 RS-485 p.240~269 (PDF 254~283)","en":"chapter 7 RS-485 pp.240-269 (PDF 254-283)"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"ls-electric/h100","manufacturer":{"ko":"LS일렉트릭","en":"LS ELECTRIC"},"model":"LSLV-H100","models":["H100"],"kind":"inverter","title":{"ko":"LS일렉트릭 H100 팬·펌프용 인버터 (내장 RS-485)","en":"LS ELECTRIC H100 fan & pump drive (built-in RS-485)"},"summary":{"ko":"팬·펌프(HVAC)용 인버터. 내장 RS-485 Modbus-RTU·LS INV 485·BACnet·Metasys-N2. 호환 공통 영역(0h0001~0h001B), 모니터 영역(0h0300~), 제어 영역(0h0380~), 메모리 제어(0h03E0)를 담았다.","en":"Fan/pump (HVAC) drive. Built-in RS-485 with Modbus-RTU, LS INV 485, BACnet, Metasys-N2. Covers the compatible common area (0h0001-0h001B), monitor area (0h0300-), control area (0h0380-) and memory control (0h03E0)."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,250],"addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼이 함수 코드 설명에 «Start Addr. = 시작 주소-1» 이라고 적고(p.347~348), 사용 예(p.349)에서 통신 번지 0x1103 을 0x1102 로 보낸다. 그래서 address = 매뉴얼 통신 번지 - 1. 0h0000(인버터 모델)은 -1 이 되어 뺐다.","en":"Addressing: the manual states 'Start Addr. = start address - 1' for each function code (p.347-348) and its example (p.349) sends comm address 0x1103 as 0x1102, so address = manual address - 1. 0h0000 (model) maps to -1 and is omitted."},{"ko":"초기값: COM-01 국번 1(1~250, BACnet 이면 127·Serve Drv 면 8), COM-02 0 Modbus-RTU, COM-03 3=9600bps, COM-04 0=D8/PN/S1. COM-03 은 0~8 = 1200·2400·4800·9600·19200·38400·57600·76800·115200, COM-04 는 8N1·8E1·8O1. p.333~334 (PDF 350~351).","en":"Defaults: COM-01 ID 1 (1-250; 127 for BACnet, 8 for Serve Drv), COM-02 0 Modbus-RTU, COM-03 3 = 9600 bps, COM-04 0 = D8/PN/S1. COM-03 0-8 = 1200/2400/4800/9600/19200/38400/57600/76800/115200; COM-04 offers 8N1/8E1/8O1. p.333-334 (PDF 350-351)."},{"ko":"함수 코드 03·04(같게 처리, 최대 16개)·06·16, 예외 코드 01·02·03·06·14(쓰기 보호) (p.347~349).","en":"Function codes 03/04 (handled the same, up to 16 registers), 06, 16; exception codes 01/02/03/06/14 (write protection) (p.347-349)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"0h0001","type":"u16","name":{"ko":"인버터 용량","en":"Inverter capacity"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"0.75kW","en":"0.75kW"},{"value":1,"ko":"1.5kW","en":"1.5kW"},{"value":2,"ko":"2.2kW","en":"2.2kW"},{"value":3,"ko":"3.7kW","en":"3.7kW"},{"value":4,"ko":"5.5kW","en":"5.5kW"},{"value":5,"ko":"7.5kW","en":"7.5kW"},{"value":6,"ko":"11kW","en":"11kW"},{"value":7,"ko":"15kW","en":"15kW"},{"value":8,"ko":"18.5kW","en":"18.5kW"},{"value":9,"ko":"22kW","en":"22kW"},{"value":10,"ko":"30kW","en":"30kW"},{"value":11,"ko":"37kW","en":"37kW"},{"value":12,"ko":"45kW","en":"45kW"},{"value":13,"ko":"55kW","en":"55kW"},{"value":14,"ko":"75kW","en":"75kW"},{"value":15,"ko":"90kW","en":"90kW"},{"value":16,"ko":"110kW","en":"110kW"},{"value":17,"ko":"132kW","en":"132kW"},{"value":18,"ko":"160kW","en":"160kW"},{"value":19,"ko":"185kW","en":"185kW"},{"value":20,"ko":"220kW","en":"220kW"},{"value":21,"ko":"250kW","en":"250kW"},{"value":22,"ko":"315kW","en":"315kW"},{"value":23,"ko":"355kW","en":"355kW"},{"value":24,"ko":"400kW","en":"400kW"},{"value":25,"ko":"500kW","en":"500kW"}],"ref":"p.350 (PDF 367)"},{"table":"holding-registers","address":1,"manualAddress":"0h0002","type":"u16","name":{"ko":"입력 전압 등급","en":"Input voltage class"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"220V 급","en":"220 V class"},{"value":1,"ko":"440V 급","en":"440 V class"}],"ref":"p.350 (PDF 367)"},{"table":"holding-registers","address":2,"manualAddress":"0h0003","type":"u16","name":{"ko":"버전","en":"Version"},"access":"r","fc":[3,4],"description":{"ko":"예: 0h0064 = 버전 1.00, 0h0065 = 버전 1.01","en":"Example: 0h0064 = version 1.00, 0h0065 = version 1.01"},"ref":"p.350 (PDF 367)"},{"table":"holding-registers","address":4,"manualAddress":"0h0005","type":"u16","name":{"ko":"목표 주파수","en":"Target frequency"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.350 (PDF 367)"},{"table":"holding-registers","address":5,"manualAddress":"0h0006","type":"u16","name":{"ko":"운전 지령","en":"Operation command"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"정지(S)","en":"Stop (S)"},{"bit":1,"ko":"정방향 운전(F)","en":"Forward run (F)"},{"bit":2,"ko":"역방향 운전(R)","en":"Reverse run (R)"},{"bit":3,"ko":"트립 초기화(0→1) / 읽기: 트립 상태","en":"Trip reset (0→1) / read: trip state"},{"bit":4,"ko":"프리런 정지","en":"Free-run stop"}],"description":{"ko":"B0~B4 읽기·쓰기, B5 예약. B6~B8(읽기) 운전 지령 소스: 0 키패드, 1 Fx/Rx-1, 2 Fx/Rx-2, 3 내장형 485, 4 통신 옵션, 5 Time Event. B9~B14(읽기) 주파수 지령 소스: 0 키패드 주파수, 2~8 단자대 다단속, 17 Up, 18 Down, 19 STEADY, 22 V1, 24 V2, 25 I2, 26 PULSE, 27 내장형 485, 28 통신 옵션, 30 JOG, 31 PID. B15 예약.","en":"B0-B4 read/write, B5 reserved. B6-B8 (read) run command source: 0 keypad, 1 Fx/Rx-1, 2 Fx/Rx-2, 3 built-in 485, 4 comm option, 5 time event. B9-B14 (read) frequency source: 0 keypad freq, 2-8 terminal multi-step, 17 up, 18 down, 19 steady, 22 V1, 24 V2, 25 I2, 26 pulse, 27 built-in 485, 28 comm option, 30 jog, 31 PID. B15 reserved."},"ref":"p.350 (PDF 367)"},{"table":"holding-registers","address":6,"manualAddress":"0h0007","type":"u16","name":{"ko":"가속 시간","en":"Acceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":7,"manualAddress":"0h0008","type":"u16","name":{"ko":"감속 시간","en":"Deceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":8,"manualAddress":"0h0009","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":9,"manualAddress":"0h000A","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":10,"manualAddress":"0h000B","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":11,"manualAddress":"0h000C","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":12,"manualAddress":"0h000D","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":13,"manualAddress":"0h000E","type":"u16","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"정지","en":"Stopped"},{"bit":1,"ko":"정방향 운전 중","en":"Running forward"},{"bit":2,"ko":"역방향 운전 중","en":"Running reverse"},{"bit":3,"ko":"고장(트립) — OUT-30 설정에 따름","en":"Fault (trip), per OUT-30 setting"},{"bit":4,"ko":"가속 중","en":"Accelerating"},{"bit":5,"ko":"감속 중","en":"Decelerating"},{"bit":6,"ko":"속도 도달","en":"Speed reached"},{"bit":7,"ko":"직류 제동 중","en":"DC braking"},{"bit":8,"ko":"감속 정지 중","en":"Decelerating to stop"},{"bit":9,"ko":"조그 모드","en":"Jog mode"},{"bit":11,"ko":"정방향 운전 지령","en":"Forward run command"},{"bit":12,"ko":"역방향 운전 지령","en":"Reverse run command"},{"bit":13,"ko":"운전 지령 소스가 통신(내장형·옵션)","en":"Run command source is communication"},{"bit":14,"ko":"주파수 지령 소스가 통신(내장형·옵션)","en":"Frequency source is communication"},{"bit":15,"ko":"0 HAND, 1 AUTO","en":"0 HAND, 1 AUTO"}],"ref":"p.351 (PDF 368)"},{"table":"holding-registers","address":14,"manualAddress":"0h000F","type":"u16","name":{"ko":"트립 정보","en":"Trip information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"래치형 트립","en":"Latch type trip"},{"bit":3,"ko":"레벨형 트립","en":"Level type trip"},{"bit":10,"ko":"H/W 진단","en":"H/W diagnosis"}],"ref":"p.352 (PDF 369)"},{"table":"holding-registers","address":15,"manualAddress":"0h0010","type":"u16","name":{"ko":"입력 단자 정보","en":"Input terminal information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"P1","en":"P1"},{"bit":1,"ko":"P2","en":"P2"},{"bit":2,"ko":"P3","en":"P3"},{"bit":3,"ko":"P4","en":"P4"},{"bit":4,"ko":"P5","en":"P5"},{"bit":5,"ko":"P6","en":"P6"},{"bit":6,"ko":"P7","en":"P7"}],"ref":"p.352 (PDF 369)"},{"table":"holding-registers","address":16,"manualAddress":"0h0011","type":"u16","name":{"ko":"출력 단자 정보","en":"Output terminal information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"Relay 1","en":"Relay 1"},{"bit":1,"ko":"Relay 2","en":"Relay 2"},{"bit":2,"ko":"Relay 3","en":"Relay 3"},{"bit":3,"ko":"Relay 4","en":"Relay 4"},{"bit":4,"ko":"Relay 5","en":"Relay 5"},{"bit":5,"ko":"Q1","en":"Q1"}],"description":{"ko":"B6~B8 예약(확장 IO 연결 시 Relay 8~6)","en":"B6-B8 reserved (Relay 8-6 with extension IO)"},"ref":"p.352 (PDF 369)"},{"table":"holding-registers","address":17,"manualAddress":"0h0012","type":"u16","name":{"ko":"V1 전압 입력","en":"V1 voltage input"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":18,"manualAddress":"0h0013","type":"u16","name":{"ko":"Thermal 입력","en":"Thermal input"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":19,"manualAddress":"0h0014","type":"u16","name":{"ko":"V2 전압 입력","en":"V2 voltage input"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":20,"manualAddress":"0h0015","type":"u16","name":{"ko":"I2 전류 입력","en":"I2 current input"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":21,"manualAddress":"0h0016","type":"u16","name":{"ko":"모터 회전 속도","en":"Motor speed"},"unit":"rpm","access":"r","fc":[3,4],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":25,"manualAddress":"0h001A","type":"u16","name":{"ko":"Hz/Rpm 선택","en":"Hz/Rpm selection"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"Hz 단위","en":"Hz"},{"value":1,"ko":"Rpm 단위","en":"rpm"}],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":26,"manualAddress":"0h001B","type":"u16","name":{"ko":"선택된 모터 극수","en":"Selected motor poles"},"access":"r","fc":[3,4],"ref":"p.353 (PDF 370)"},{"table":"holding-registers","address":772,"manualAddress":"0h0305","type":"u16","name":{"ko":"인버터 운전 상태","en":"Inverter operation state"},"access":"r","fc":[3,4],"description":{"ko":"B15~B12: 0 정상, 4 경고, 8 고장 / B7~B4: 1 속도 써치, 2 가속, 3 정속, 4 감속, 5 감속 정지, 6 H/W 전류 억제, 7 S/W 전류 억제, 8 드웰 / B3~B0: 0 정지, 1 정방향, 2 역방향, 3 DC 운전","en":"B15-B12: 0 normal, 4 warning, 8 fault / B7-B4: 1 speed search, 2 accel, 3 steady, 4 decel, 5 decel stop, 6 H/W current suppression, 7 S/W current suppression, 8 dwell / B3-B0: 0 stop, 1 forward, 2 reverse, 3 DC"},"ref":"p.354 (PDF 371)"},{"table":"holding-registers","address":773,"manualAddress":"0h0306","type":"u16","name":{"ko":"운전·주파수 지령 소스","en":"Run / frequency command source"},"access":"r","fc":[3,4],"description":{"ko":"B15~B8 운전 지령: 0 키패드, 1 통신 옵션, 3 내장형 485, 4 단자대 / B7~B0 주파수 지령: 0 키패드 속도, 2~4 Up/Down, 5 V1, 7 V2, 8 I2, 9 Pulse, 10 내장형 485, 11 통신 옵션, 13 Jog, 14 PID, 25~31 다단속","en":"B15-B8 run command: 0 keypad, 1 comm option, 3 built-in 485, 4 terminal / B7-B0 frequency: 0 keypad speed, 2-4 up/down, 5 V1, 7 V2, 8 I2, 9 pulse, 10 built-in 485, 11 comm option, 13 jog, 14 PID, 25-31 multi-step"},"ref":"p.355 (PDF 372)"},{"table":"holding-registers","address":783,"manualAddress":"0h0310","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":784,"manualAddress":"0h0311","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":785,"manualAddress":"0h0312","type":"u16","name":{"ko":"출력 회전수","en":"Output speed"},"unit":"rpm","access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":787,"manualAddress":"0h0314","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":788,"manualAddress":"0h0315","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":789,"manualAddress":"0h0316","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","access":"r","fc":[3,4],"description":{"ko":"110kW 미만 용량은 0.1 kW 단위, 110kW 이상은 1 kW 단위 — 용량에 따라 배율이 다르다.","en":"0.1 kW units below 110 kW capacity, 1 kW units from 110 kW — scale depends on capacity."},"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":791,"manualAddress":"0h0318","type":"u16","name":{"ko":"PID 레퍼런스","en":"PID reference"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":792,"manualAddress":"0h0319","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.356 (PDF 373)"},{"table":"holding-registers","address":813,"manualAddress":"0h032E","type":"u16","name":{"ko":"사용 전력량(kWh)","en":"Energy (kWh)"},"unit":"kWh","scale":0.1,"access":"r","fc":[3,4],"ref":"p.357 (PDF 374)"},{"table":"holding-registers","address":814,"manualAddress":"0h032F","type":"u16","name":{"ko":"사용 전력량(MWh)","en":"Energy (MWh)"},"unit":"MWh","access":"r","fc":[3,4],"ref":"p.357 (PDF 374)"},{"table":"holding-registers","address":860,"manualAddress":"0h035D","type":"u16","name":{"ko":"인버터 내부 온도","en":"Inverter temperature"},"unit":"℃","access":"r","fc":[3,4],"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":861,"manualAddress":"0h035E","type":"u16","name":{"ko":"출력 역률","en":"Power factor"},"scale":0.1,"access":"r","fc":[3,4],"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":864,"manualAddress":"0h0361","type":"u16","name":{"ko":"현재 출력 토크","en":"Output torque"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"description":{"ko":"모터 정격 토크 대비 %","en":"Percent of motor rated torque"},"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":895,"manualAddress":"0h0380","type":"u16","name":{"ko":"주파수 지령(확장)","en":"Frequency command (ext.)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":896,"manualAddress":"0h0381","type":"u16","name":{"ko":"Rpm 지령","en":"Rpm command"},"unit":"rpm","access":"rw","fc":[3,4,6,16],"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":897,"manualAddress":"0h0382","type":"u16","name":{"ko":"운전 지령(확장)","en":"Operation command (ext.)"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"0 정지 / 1 런","en":"0 stop / 1 run"},{"bit":1,"ko":"0 역방향 / 1 정방향","en":"0 reverse / 1 forward"},{"bit":2,"ko":"트립 초기화(0→1)","en":"Trip reset (0→1)"},{"bit":3,"ko":"프리런 정지(0→1)","en":"Free-run stop (0→1)"}],"description":{"ko":"예: 정방향 운전 0003h, 역방향 운전 0001h","en":"Example: forward run 0003h, reverse run 0001h"},"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":898,"manualAddress":"0h0383","type":"u16","name":{"ko":"가속 시간(확장)","en":"Acceleration time (ext.)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.361 (PDF 378)"},{"table":"holding-registers","address":899,"manualAddress":"0h0384","type":"u16","name":{"ko":"감속 시간(확장)","en":"Deceleration time (ext.)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.362 (PDF 379)"},{"table":"holding-registers","address":903,"manualAddress":"0h0388","type":"u16","name":{"ko":"PID 레퍼런스 지령","en":"PID reference (comm)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.362 (PDF 379)"},{"table":"holding-registers","address":904,"manualAddress":"0h0389","type":"u16","name":{"ko":"PID 피드백 값","en":"PID feedback (comm)"},"unit":"%","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.362 (PDF 379)"},{"table":"holding-registers","address":991,"manualAddress":"0h03E0","type":"u16","name":{"ko":"파라미터 저장","en":"Save parameters"},"access":"rw","fc":[3,4,6,16],"values":[{"value":0,"ko":"아니오","en":"No"},{"value":1,"ko":"예","en":"Yes"}],"description":{"ko":"0 을 쓴 뒤 1 을 쓰면 저장(p.337). 운전 중 변경 불가","en":"Write 0 then 1 to save (p.337). Not changeable during run"},"ref":"p.364 (PDF 381)"}],"notes":[{"ko":"통신으로 운전·주파수를 주려면 DRV-06=3(Int 485)·DRV-07=6(Int 485) (p.335).","en":"Set DRV-06 = 3 (Int 485) and DRV-07 = 6 (Int 485) to command over RS-485 (p.335)."},{"ko":"통신으로 바꾼 값은 전원을 끄면 이전 값으로 돌아간다. CNF-48=1 이나 0h03E0 에 0 → 1 을 쓰면 저장 (p.337). 0h0380·0h0005 로 준 주파수는 저장해도 남지 않는다 (p.364).","en":"Values changed over comm revert at power-off unless saved via CNF-48 = 1 or by writing 0 then 1 to 0h03E0 (p.337). Frequency written to 0h0380/0h0005 is not retained even after save (p.364)."},{"ko":"0h0000~0h0011 은 다른 LS 인버터와 같은 공통 영역, 0h0012~0h001B 는 H100 전용 (p.350). 0h0004 는 Reserved.","en":"0h0000-0h0011 are shared with other LS drives; 0h0012-0h001B are H100-specific (p.350). 0h0004 is reserved."}],"sources":[{"title":"H100 국문 완전본 매뉴얼 (H100_User Manual_Kor_V3.0_260422.pdf) — LSLV-H100","publisher":"LS ELECTRIC","edition":{"ko":"파일 V3.0, 2026-04-22","en":"file V3.0, 2026-04-22"},"url":"https://sftpssqblobcdn.blob.core.windows.net/prod/largefile/document/17781296910160/H100_User%20Manual_Kor_V3.0_260422.pdf","pages":{"ko":"7장 RS-485 p.333~364 (PDF 350~381)","en":"chapter 7 RS-485 pp.333-364 (PDF 350-381)"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"ls-electric/m100","manufacturer":{"ko":"LS일렉트릭","en":"LS ELECTRIC"},"model":"LSLV-M100","models":["M100"],"kind":"inverter","title":{"ko":"LS일렉트릭 M100 인버터 (내장 RS-485, 고급 I/O 모델)","en":"LS ELECTRIC M100 AC drive (built-in RS-485, advanced I/O models)"},"summary":{"ko":"고급 I/O 모델만 내장 RS-485(RJ45). Modbus-RTU 와 LS INV 485. G100·S100·H100·iS7·S300 호환 공통 영역(0x0001~0x001E)을 담았다.","en":"Built-in RS-485 (RJ45) on advanced I/O models only; Modbus-RTU and LS INV 485. Covers the common area compatible with G100/S100/H100/iS7/S300 (0x0001-0x001E)."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,250],"addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼 Modbus-RTU 통신 예(p.191, PDF 203)에서 통신 주소 0x1103 에 쓸 때 프레임 시작 주소를 0x1102(«Starting Address -1»)로 보낸다. 그래서 address = 매뉴얼 주소 - 1 로 적었다. 예는 파라미터 영역 하나뿐이고, 이 규칙대로면 0x0000(인버터 모델)은 -1 이 되어 표현할 수 없어 뺐다. 공통 영역에도 같은 규칙이 맞는지 실기로 확인 권장.","en":"Addressing: the manual's Modbus-RTU example (p.191, PDF 203) sends starting address 0x1102 for comm address 0x1103 ('Starting Address -1'), so address = manual address - 1. The example is from the parameter area only; under this rule 0x0000 (model) maps to -1 and is omitted. Verify on hardware for the common area."},{"ko":"초기값: CM.01 국번 1(1~250), CM.02 0 Modbus-RTU(1 LS INV 485), CM.03 3=9600bps(0~5 = 1200~38400), CM.04 0=D8/PN/S1. CM.04 는 8N1·8N2·8E1·8O1. p.179~180 (PDF 191~192).","en":"Defaults: CM.01 ID 1 (1-250), CM.02 0 Modbus-RTU (1 LS INV 485), CM.03 3 = 9600 bps (0-5 = 1200-38400), CM.04 0 = D8/PN/S1; CM.04 offers 8N1/8N2/8E1/8O1. p.179-180 (PDF 191-192)."},{"ko":"CM.03 설명엔 «115,200 bps 까지» 라고 적혀 있으나 설정표와 규격표(p.177)는 1,200~38,400 bps 뿐이라 그 범위만 넣었다.","en":"The CM.03 text says 'up to 115,200 bps', but the setting table and spec table (p.177) list only 1,200-38,400 bps, so only those are listed."},{"ko":"함수 코드 03·04·06·16, 예외 코드 01·02·03·06 (p.189~190, PDF 201~202). 최대 16대, RJ45 1번 S+·8번 S- (p.177~179).","en":"Function codes 03, 04, 06, 16; exception codes 01/02/03/06 (p.189-190, PDF 201-202). Up to 16 drives, RJ45 pin 1 S+ / pin 8 S- (p.177-179)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"0x0001","type":"u16","name":{"ko":"인버터 용량","en":"Inverter capacity"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"0.1kW-1","en":"0.1kW-1"},{"value":1,"ko":"0.2kW-1","en":"0.2kW-1"},{"value":2,"ko":"0.4kW-1","en":"0.4kW-1"},{"value":3,"ko":"0.8kW-1","en":"0.8kW-1"},{"value":4,"ko":"1.5kW-1","en":"1.5kW-1"},{"value":5,"ko":"2.2kW-1","en":"2.2kW-1"},{"value":10,"ko":"1.5kW-2","en":"1.5kW-2"},{"value":11,"ko":"2.2kW-2","en":"2.2kW-2"},{"value":12,"ko":"3.7kW-2","en":"3.7kW-2"},{"value":15,"ko":"0.4kW-4","en":"0.4kW-4"},{"value":16,"ko":"0.8kW-4","en":"0.8kW-4"},{"value":17,"ko":"1.5kW-4","en":"1.5kW-4"},{"value":18,"ko":"2.2kW-4","en":"2.2kW-4"},{"value":19,"ko":"3.7kW-4","en":"3.7kW-4"}],"description":{"ko":"값 이름은 매뉴얼 표기 그대로(16진 000A=10, 000F=15 …).","en":"Value names as printed (hex 000A = 10, 000F = 15 …)."},"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":1,"manualAddress":"0x0002","type":"u16","name":{"ko":"입력 전압","en":"Inverter input voltage"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"220V 단상","en":"220 V 1-phase"},{"value":1,"ko":"220V 3상","en":"220 V 3-phase"},{"value":2,"ko":"440V 3상","en":"440 V 3-phase"}],"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":2,"manualAddress":"0x0003","type":"u16","name":{"ko":"버전","en":"Version"},"access":"r","fc":[3,4],"description":{"ko":"공통 영역 S/W 버전은 16진으로 표시(p.194 주 2). 매뉴얼 예: 0x0010 = 버전 1.01(표기 그대로).","en":"Common-area S/W version is shown in hex (p.194 note 2). Manual example: 0x0010 = version 1.01 (as printed)."},"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":3,"manualAddress":"0x0004","type":"u16","name":{"ko":"통신 설정 허용","en":"Parameter setting (comm)"},"access":"rw","fc":[3,4,6,16],"values":[{"value":0,"ko":"통신 설정 금지","en":"Prohibit communication settings"},{"value":1,"ko":"통신 설정 허용","en":"Allow communication settings"}],"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":4,"manualAddress":"0x0005","type":"u16","name":{"ko":"주파수 지령","en":"Command frequency"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"description":{"ko":"시작 주파수~최대 주파수","en":"Start frequency to maximum frequency"},"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":5,"manualAddress":"0x0006","type":"u16","name":{"ko":"운전 지령","en":"Operation command"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"정지","en":"Stop"},{"bit":1,"ko":"정방향 운전","en":"Forward operation"},{"bit":2,"ko":"역방향 운전","en":"Reverse operation"},{"bit":3,"ko":"고장 리셋","en":"Fault reset"},{"bit":4,"ko":"비상 정지","en":"Emergency stop"}],"description":{"ko":"B0~B4 쓰기 가능, B5 예약. B6~B7(읽기) 운전 지령 소스: 0 단자대, 1 키패드, 3 통신. B8~B12(읽기) 주파수 지령 소스: 0 키패드-1·2, 2~8 다단속 1~7, 9 Up, 10 Down, 11 Up/down zero, 12 V0, 13 V1, 14 I2(I), 15 I2(V), 16 V0+I2(I), 17 V0+I2(V), 18 V0+I2(V)(표기 그대로), 19 통신 운전. B13~B15 예약.","en":"B0-B4 writable, B5 reserved. B6-B7 (read) run command source: 0 terminal block, 1 keypad, 3 communication. B8-B12 (read) frequency source: 0 keypad-1/2, 2-8 multi-step speed 1-7, 9 up, 10 down, 11 up/down zero, 12 V0, 13 V1, 14 I2(I), 15 I2(V), 16 V0+I2(I), 17 V0+I2(V), 18 V0+I2(V) (as printed), 19 communication. B13-B15 reserved."},"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":6,"manualAddress":"0x0007","type":"u16","name":{"ko":"가속 시간","en":"Acceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":7,"manualAddress":"0x0008","type":"u16","name":{"ko":"감속 시간","en":"Deceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.192 (PDF 204)"},{"table":"holding-registers","address":8,"manualAddress":"0x0009","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":9,"manualAddress":"0x000A","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":10,"manualAddress":"0x000B","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":11,"manualAddress":"0x000C","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":12,"manualAddress":"0x000D","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":13,"manualAddress":"0x000E","type":"u16","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"정지","en":"Stopped"},{"bit":1,"ko":"정방향 운전 중","en":"Operating in forward direction"},{"bit":2,"ko":"역방향 운전 중","en":"Operating in reverse direction"},{"bit":3,"ko":"고장 트립","en":"Fault trip"},{"bit":4,"ko":"가속 중","en":"Accelerating"},{"bit":5,"ko":"감속 중","en":"Decelerating"},{"bit":6,"ko":"속도 도달","en":"Speed reached"},{"bit":7,"ko":"직류 제동","en":"DC braking"},{"bit":8,"ko":"정지 중","en":"Drive stopping"},{"bit":10,"ko":"브레이크 개방 신호","en":"Brake release signal"},{"bit":11,"ko":"정방향 지령","en":"Forward command"},{"bit":12,"ko":"역방향 지령","en":"Reverse command"}],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":14,"manualAddress":"0x000F","type":"u16","name":{"ko":"고장 트립 정보 A","en":"Fault trip information A"},"access":"r","fc":[3,4],"bits":[{"bit":1,"ko":"OVT","en":"OVT"},{"bit":2,"ko":"EXT-A","en":"EXT-A"},{"bit":3,"ko":"EST","en":"EST"},{"bit":4,"ko":"COL","en":"COL"},{"bit":5,"ko":"GFT","en":"GFT"},{"bit":6,"ko":"OHT","en":"OHT"},{"bit":7,"ko":"ETH","en":"ETH"},{"bit":8,"ko":"OLT","en":"OLT"},{"bit":10,"ko":"EXT-B","en":"EXT-B"},{"bit":11,"ko":"EEP","en":"EEP"},{"bit":12,"ko":"FAN","en":"FAN"},{"bit":13,"ko":"POT","en":"POT"},{"bit":14,"ko":"IOLT","en":"IOLT"},{"bit":15,"ko":"LVT","en":"LVT"}],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":15,"manualAddress":"0x0010","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"P1","en":"P1"},{"bit":1,"ko":"P2","en":"P2"},{"bit":2,"ko":"P3","en":"P3"},{"bit":3,"ko":"P4","en":"P4"},{"bit":4,"ko":"P5","en":"P5"}],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":16,"manualAddress":"0x0011","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal information"},"access":"r","fc":[3,4],"bits":[{"bit":4,"ko":"3ABC","en":"3ABC"}],"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":17,"manualAddress":"0x0012","type":"u16","name":{"ko":"V1 입력","en":"V1 input"},"access":"r","fc":[3,4],"range":{"min":0,"max":1023},"description":{"ko":"0~10 V 입력에 대응하는 0x0000~0x03FF","en":"0x0000-0x03FF for 0-10 V input"},"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":18,"manualAddress":"0x0013","type":"u16","name":{"ko":"V0 입력(KPD 볼륨)","en":"V0 input (keypad volume)"},"access":"r","fc":[3,4],"range":{"min":0,"max":1023},"description":{"ko":"0~5 V KPD 볼륨 0x0000~0x03FF","en":"0-5 V keypad volume, 0x0000-0x03FF"},"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":19,"manualAddress":"0x0014","type":"u16","name":{"ko":"I 입력","en":"I input"},"access":"r","fc":[3,4],"range":{"min":0,"max":1023},"description":{"ko":"0~20 mA 입력에 대응하는 0x0000~0x03FF","en":"0x0000-0x03FF for 0-20 mA input"},"ref":"p.193 (PDF 205)"},{"table":"holding-registers","address":20,"manualAddress":"0x0015","type":"u16","name":{"ko":"회전수","en":"RPM"},"access":"r","fc":[3,4],"ref":"p.194 (PDF 206)"},{"table":"holding-registers","address":28,"manualAddress":"0x001D","type":"u16","name":{"ko":"고장 트립 정보 B","en":"Fault trip information B"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"COM","en":"COM"},{"bit":2,"ko":"NTC","en":"NTC"},{"bit":3,"ko":"REEP","en":"REEP"},{"bit":4,"ko":"OCT","en":"OCT"},{"bit":5,"ko":"NBR","en":"NBR"},{"bit":9,"ko":"ROT","en":"ROT"}],"ref":"p.194 (PDF 206)"},{"table":"holding-registers","address":29,"manualAddress":"0x001E","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.1,"access":"rw","fc":[3,4,6,16],"description":{"ko":"PID 피드백을 통신으로 줄 때 0.1% 단위로 쓰고 읽는다(AP.02 단위 설정과 무관). 예: 최대 주파수 60.00 Hz 에 0x0032(5.0%) → 3.00 Hz.","en":"Written/read in 0.1% when PID feedback is set to communication, regardless of AP.02. Example: max 60.00 Hz, 0x0032 (5.0%) → 3.00 Hz."},"ref":"p.194 (PDF 206)"}],"notes":[{"ko":"RS-485 는 고급 I/O(Advanced I/O) 모델만 (p.177).","en":"RS-485 is available only on models with advanced I/O (p.177)."},{"ko":"통신으로 운전·주파수를 주려면 drv=3(Int 485)·Frq=9(Int 485) (p.181, PDF 193).","en":"Set drv = 3 (Int 485) and Frq = 9 (Int 485) to command over RS-485 (p.181, PDF 193)."},{"ko":"공통 영역으로 바꾼 값은 저장되지 않아 리셋·전원 재투입 때 이전 값으로 돌아간다. 각 그룹 파라미터로 바꾼 값은 남는다 (p.194 주 1).","en":"Values changed via the common area are not saved and revert on reset/power cycle; changes via group parameters are retained (p.194 note 1)."},{"ko":"0x001A 단위 표시·0x001B 극수·0x001C 커스텀 버전은 «Not Used», 0x0100~0x010F 는 CM.31~38·CM.51~58 에 등록한 주소의 읽기·쓰기 창 (p.194).","en":"0x001A unit display, 0x001B poles, 0x001C custom version are 'Not Used'; 0x0100-0x010F are read/write windows for addresses registered in CM.31-38 and CM.51-58 (p.194)."}],"sources":[{"title":"M100 User Manual (M100_User Manual_EN_V2.3_260223.pdf) — LSLV-M100","publisher":"LS ELECTRIC","edition":{"ko":"파일 V2.3, 2026-02-23 (Revision History 마지막 줄 V2.0 2022.09, p.254)","en":"file V2.3, 2026-02-23 (last Revision History entry V2.0 2022.09, p.254)"},"url":"https://ssq.ls-electric.com/uploads/document/17719093868370/M100_User%20Manual_EN_V2.3_260223.pdf","pages":{"ko":"8장 RS-485 p.177~194 (PDF 189~206)","en":"chapter 8 RS-485 pp.177-194 (PDF 189-206)"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"ls-electric/s100","manufacturer":{"ko":"LS일렉트릭","en":"LS ELECTRIC"},"model":"LSLV-S100","models":["S100"],"kind":"inverter","title":{"ko":"LS일렉트릭 S100 인버터 (내장 RS-485)","en":"LS ELECTRIC S100 AC drive (built-in RS-485)"},"summary":{"ko":"내장 RS-485 Modbus-RTU. iS5·iP5A·iV5·iG5A 호환 공통 영역(0h0000~)과 S100 확장 공통 영역(0h0300~)","en":"Built-in RS-485 Modbus-RTU. Compatible common area (0h0000-) and S100 expansion common area (0h0300-)"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,250],"addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼 Modbus-RTU 통신 예(p.295, PDF 309)에서 통신 주소 0x1103 에 쓸 때 프레임 시작 주소를 0x1102(«Starting Address -1»)로 보낸다. 그래서 address = 매뉴얼 주소 - 1 로 적었다. 예는 파라미터 영역 하나뿐이고, 이 규칙대로면 0h0000(인버터 모델)은 -1 이 되어 표현할 수 없어 뺐다. 공통 영역에도 같은 규칙이 맞는지 실기로 확인 권장.","en":"Addressing: the manual's Modbus-RTU example (p.295, PDF 309) sends starting address 0x1102 for comm address 0x1103 ('Starting Address -1'), so address = manual address - 1. The example is from the parameter area only; under this rule 0h0000 (model) maps to -1 and is omitted. Verify on hardware for the common area."},{"ko":"초기값: CM.01 국번 1(1~250), CM.02 프로토콜 0 Modbus-RTU, CM.03 속도 3=9600bps, CM.04 0=D8/PN/S1(8N1). p.281 (PDF 295), p.346 (PDF 360).","en":"Defaults: CM.01 ID 1 (1-250), CM.02 0 Modbus-RTU, CM.03 3 = 9600 bps, CM.04 0 = D8/PN/S1. p.281 (PDF 295), p.346 (PDF 360)."},{"ko":"CM.03 설정 6 은 매뉴얼 표에 56000bps 로, 7.1 규격표(p.279)에는 57,600bps 로 적혀 있어 bauds 에서 뺐다. CM.04 는 8N1·8N2·8E1·8O1 (p.281).","en":"CM.03 setting 6 reads 56000 bps in the CM table but 57,600 bps in the spec table (p.279), so it is left out of bauds. CM.04 offers 8N1/8N2/8E1/8O1 (p.281)."},{"ko":"함수 코드 03·04·06·16 지원 (p.292~294, PDF 306~308).","en":"Function codes 03, 04, 06, 16 supported (p.292-294, PDF 306-308)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"0h0001","type":"u16","name":{"ko":"인버터 용량","en":"Inverter capacity"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"0.75kW","en":"0.75kW"},{"value":1,"ko":"1.5kW","en":"1.5kW"},{"value":2,"ko":"2.2kW","en":"2.2kW"},{"value":3,"ko":"3.7kW","en":"3.7kW"},{"value":4,"ko":"5.5kW","en":"5.5kW"},{"value":5,"ko":"7.5kW","en":"7.5kW"},{"value":6,"ko":"11kW","en":"11kW"},{"value":7,"ko":"15kW","en":"15kW"},{"value":8,"ko":"18.5kW","en":"18.5kW"},{"value":9,"ko":"22kW","en":"22kW"},{"value":10,"ko":"30kW","en":"30kW"},{"value":11,"ko":"37kW","en":"37kW"},{"value":12,"ko":"45kW","en":"45kW"},{"value":13,"ko":"55kW","en":"55kW"},{"value":14,"ko":"75kW","en":"75kW"},{"value":256,"ko":"0.4kW","en":"0.4kW"},{"value":257,"ko":"1.1kW","en":"1.1kW"},{"value":258,"ko":"3.0kW","en":"3.0kW"},{"value":259,"ko":"4.0kW","en":"4.0kW"}],"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":1,"manualAddress":"0h0002","type":"u16","name":{"ko":"입력 전압 등급","en":"Input voltage class"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"220V 제품","en":"220V product"},{"value":1,"ko":"440V 제품","en":"440V product"}],"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":2,"manualAddress":"0h0003","type":"u16","name":{"ko":"S/W 버전","en":"S/W version"},"access":"r","fc":[3,4],"description":{"ko":"16진: 0x0100 = 버전 1.00","en":"Hex: 0x0100 = version 1.00"},"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":4,"manualAddress":"0h0005","type":"u16","name":{"ko":"주파수 지령","en":"Frequency command"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":5,"manualAddress":"0h0006","type":"u16","name":{"ko":"운전 지령","en":"Operation command"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"정지(S)","en":"Stop (S)"},{"bit":1,"ko":"정방향 운전(F)","en":"Forward run (F)"},{"bit":2,"ko":"역방향 운전(R)","en":"Reverse run (R)"},{"bit":3,"ko":"쓰기: 트립 리셋(0→1) / 읽기: 트립 상태","en":"W: trip reset (0->1) / R: trip status"},{"bit":4,"ko":"비상 정지","en":"Emergency stop"}],"description":{"ko":"B5~B15 는 읽기 전용: B6~B8 운전 지령 소스(0 키패드, 1 Fx/Rx-1, 2 Fx/Rx-2, 3 내장 485, 4 통신 옵션), B9~B14 주파수 지령 소스(0 키패드 주파수, 1 키패드 토크, 2~16 단자대 다단속, 17 Up, 18 Down, 19 STEADY, 22 V1, 24 V2, 25 I2, 27 내장 485, 28 통신 옵션, 30 JOG, 31 PID)","en":"B5-B15 read-only: B6-B8 run command source (0 keypad, 1 Fx/Rx-1, 2 Fx/Rx-2, 3 built-in 485, 4 comm option), B9-B14 frequency source (0 keypad freq, 1 keypad torque, 2-16 multi-step, 17 up, 18 down, 19 steady, 22 V1, 24 V2, 25 I2, 27 built-in 485, 28 comm option, 30 jog, 31 PID)"},"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":6,"manualAddress":"0h0007","type":"u16","name":{"ko":"가속 시간","en":"Acceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":7,"manualAddress":"0h0008","type":"u16","name":{"ko":"감속 시간","en":"Deceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.296 (PDF 310)"},{"table":"holding-registers","address":8,"manualAddress":"0h0009","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":9,"manualAddress":"0h000A","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":10,"manualAddress":"0h000B","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":11,"manualAddress":"0h000C","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":12,"manualAddress":"0h000D","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":13,"manualAddress":"0h000E","type":"u16","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"정지","en":"Stopped"},{"bit":1,"ko":"정방향 운전 중","en":"Running forward"},{"bit":2,"ko":"역방향 운전 중","en":"Running reverse"},{"bit":3,"ko":"고장 트립","en":"Fault trip"},{"bit":4,"ko":"가속 중","en":"Accelerating"},{"bit":5,"ko":"감속 중","en":"Decelerating"},{"bit":6,"ko":"속도 도달","en":"Speed reached"},{"bit":7,"ko":"직류 제동","en":"DC braking"},{"bit":8,"ko":"정지 중","en":"Drive stopping"},{"bit":9,"ko":"조그 모드","en":"Jog mode"},{"bit":10,"ko":"브레이크 개방 신호","en":"Brake release signal"},{"bit":11,"ko":"정방향 운전 지령","en":"Forward run command"},{"bit":12,"ko":"역방향 운전 지령","en":"Reverse run command"},{"bit":13,"ko":"운전 지령이 통신(내장·옵션)","en":"Run command source is communication"},{"bit":14,"ko":"주파수 지령이 통신(내장·옵션)","en":"Frequency command source is communication"}],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":14,"manualAddress":"0h000F","type":"u16","name":{"ko":"고장 트립 정보","en":"Fault trip information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"래치형 트립","en":"Latch type trip"},{"bit":3,"ko":"레벨형 트립","en":"Level type trip"},{"bit":10,"ko":"H/W 진단 트립","en":"H/W diagnosis trip"}],"ref":"p.297 (PDF 311)"},{"table":"holding-registers","address":15,"manualAddress":"0h0010","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"P1","en":"P1"},{"bit":1,"ko":"P2","en":"P2"},{"bit":2,"ko":"P3","en":"P3"},{"bit":3,"ko":"P4","en":"P4"},{"bit":4,"ko":"P5","en":"P5"},{"bit":5,"ko":"P6","en":"P6"},{"bit":6,"ko":"P7","en":"P7"}],"ref":"p.298 (PDF 312)"},{"table":"holding-registers","address":16,"manualAddress":"0h0011","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"릴레이 1","en":"Relay 1"},{"bit":1,"ko":"Q1","en":"Q1"}],"ref":"p.298 (PDF 312)"},{"table":"holding-registers","address":768,"manualAddress":"0h0301","type":"u16","name":{"ko":"인버터 용량(확장)","en":"Inverter capacity (ext.)"},"access":"r","fc":[3,4],"values":[{"value":6400,"ko":"0.4kW","en":"0.4kW"},{"value":12800,"ko":"0.75kW","en":"0.75kW"},{"value":16401,"ko":"1.1kW","en":"1.1kW"},{"value":16405,"ko":"1.5kW","en":"1.5kW"},{"value":16418,"ko":"2.2kW","en":"2.2kW"},{"value":16432,"ko":"3.0kW","en":"3.0kW"},{"value":16439,"ko":"3.7kW","en":"3.7kW"},{"value":16448,"ko":"4.0kW","en":"4.0kW"},{"value":16469,"ko":"5.5kW","en":"5.5kW"},{"value":16501,"ko":"7.5kW","en":"7.5kW"},{"value":16560,"ko":"11kW","en":"11kW"},{"value":16624,"ko":"15kW","en":"15kW"},{"value":16677,"ko":"18.5kW","en":"18.5kW"},{"value":16736,"ko":"22kW","en":"22kW"},{"value":16864,"ko":"30kW","en":"30kW"},{"value":16976,"ko":"37kW","en":"37kW"},{"value":17104,"ko":"45kW","en":"45kW"},{"value":17264,"ko":"55kW","en":"55kW"},{"value":17584,"ko":"75kW","en":"75kW"}],"ref":"p.299 (PDF 313)"},{"table":"holding-registers","address":772,"manualAddress":"0h0305","type":"u16","name":{"ko":"인버터 운전 상태","en":"Inverter operation state"},"access":"r","fc":[3,4],"description":{"ko":"B15~B12: 0 정상, 4 경고, 8 고장 / B7~B4: 1 속도 탐색, 2 가속, 3 정속, 4 감속, 5 감속 정지, 6 H/W OCS, 7 S/W OCS, 8 드웰 / B3~B0: 0 정지, 1 정방향, 2 역방향, 3 DC 운전","en":"B15-B12: 0 normal, 4 warning, 8 fault / B7-B4: 1 speed search, 2 accel, 3 steady, 4 decel, 5 decel to stop, 6 H/W OCS, 7 S/W OCS, 8 dwell / B3-B0: 0 stop, 1 forward, 2 reverse, 3 DC operation"},"ref":"p.299 (PDF 313)"},{"table":"holding-registers","address":773,"manualAddress":"0h0306","type":"u16","name":{"ko":"운전·주파수 지령 소스","en":"Run / frequency command source"},"access":"r","fc":[3,4],"description":{"ko":"B15~B8 운전 지령: 0 키패드, 1 통신 옵션, 2 사용자 시퀀스, 3 내장 485, 4 단자대 / B7~B0 주파수 지령: 0 키패드 속도, 1 키패드 토크, 2~4 Up/Down, 5 V1, 7 V2, 8 I2, 9 펄스, 10 내장 485, 11 통신 옵션, 12 사용자 시퀀스, 13 Jog, 14 PID, 25~39 다단속","en":"B15-B8 run source: 0 keypad, 1 comm option, 2 user sequence, 3 built-in 485, 4 terminal / B7-B0 freq source: 0 keypad speed, 1 keypad torque, 2-4 up/down, 5 V1, 7 V2, 8 I2, 9 pulse, 10 built-in 485, 11 comm option, 12 user sequence, 13 jog, 14 PID, 25-39 multi-step"},"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":783,"manualAddress":"0h0310","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":784,"manualAddress":"0h0311","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":787,"manualAddress":"0h0314","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":788,"manualAddress":"0h0315","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","access":"r","fc":[3,4],"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":789,"manualAddress":"0h0316","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":790,"manualAddress":"0h0317","type":"u16","name":{"ko":"출력 토크","en":"Output torque"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.300 (PDF 314)"},{"table":"holding-registers","address":812,"manualAddress":"0h032D","type":"u16","name":{"ko":"인버터 모듈 온도","en":"Inverter module temperature"},"unit":"℃","access":"r","fc":[3,4],"ref":"p.302 (PDF 316)"},{"table":"holding-registers","address":813,"manualAddress":"0h032E","type":"u16","name":{"ko":"소비 전력량(kWh)","en":"Energy consumption (kWh)"},"unit":"kWh","scale":0.1,"access":"r","fc":[3,4],"ref":"p.302 (PDF 316)"},{"table":"holding-registers","address":815,"manualAddress":"0h0330","type":"u16","name":{"ko":"래치형 트립 정보 1","en":"Latch type trip info 1"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"과부하 트립","en":"Overload trip"},{"bit":1,"ko":"저부하 트립","en":"Underload trip"},{"bit":2,"ko":"인버터 과부하 트립","en":"Inverter overload trip"},{"bit":3,"ko":"전자 서멀 트립","en":"E-Thermal trip"},{"bit":4,"ko":"지락 트립","en":"Ground fault trip"},{"bit":5,"ko":"출력 결상 트립","en":"Output open-phase trip"},{"bit":6,"ko":"입력 결상 트립","en":"Input open-phase trip"},{"bit":9,"ko":"NTC 트립","en":"NTC trip"},{"bit":10,"ko":"과전류 트립","en":"Overcurrent trip"},{"bit":11,"ko":"과전압 트립","en":"Overvoltage trip"},{"bit":12,"ko":"외부 트립","en":"External trip"},{"bit":13,"ko":"암 단락","en":"Arm short"},{"bit":14,"ko":"과열 트립","en":"Over heat trip"},{"bit":15,"ko":"퓨즈 단선 트립","en":"Fuse open trip"}],"ref":"p.302 (PDF 316)"},{"table":"holding-registers","address":816,"manualAddress":"0h0331","type":"u16","name":{"ko":"래치형 트립 정보 2","en":"Latch type trip info 2"},"access":"r","fc":[3,4],"bits":[{"bit":2,"ko":"서멀 트립","en":"Thermal trip"},{"bit":3,"ko":"팬 트립","en":"Fan trip"},{"bit":5,"ko":"파라미터 쓰기 오류","en":"Error while writing parameter"},{"bit":6,"ko":"Pre PID 실패","en":"Pre PID fail"},{"bit":7,"ko":"기본 I/O 접촉 불량","en":"Bad contact at basic I/O board"},{"bit":8,"ko":"외부 브레이크 트립","en":"External brake trip"},{"bit":9,"ko":"모터 미연결 트립","en":"No motor trip"},{"bit":10,"ko":"옵션 카드 이상","en":"Bad option card"},{"bit":12,"ko":"Safety A","en":"Safety A"},{"bit":13,"ko":"Safety B","en":"Safety B"}],"ref":"p.302 (PDF 316)"},{"table":"holding-registers","address":817,"manualAddress":"0h0332","type":"u16","name":{"ko":"레벨형 트립 정보","en":"Level type trip info"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"BX","en":"BX"},{"bit":1,"ko":"저전압","en":"Low voltage"},{"bit":2,"ko":"지령 상실","en":"Lost command"},{"bit":3,"ko":"키패드 지령 상실","en":"Keypad lost command"},{"bit":6,"ko":"옵션 지령 상실","en":"Lost option command"},{"bit":7,"ko":"BLE 앱 상실","en":"BLE app lost"}],"ref":"p.303 (PDF 317)"},{"table":"holding-registers","address":819,"manualAddress":"0h0334","type":"u16","name":{"ko":"경고 정보","en":"Warning information"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"과부하","en":"Overload"},{"bit":1,"ko":"저부하","en":"Underload"},{"bit":2,"ko":"인버터 과부하","en":"Inverter overload"},{"bit":3,"ko":"지령 상실","en":"Lost command"},{"bit":4,"ko":"팬 운전 중","en":"Fan running"},{"bit":5,"ko":"DB","en":"DB"},{"bit":6,"ko":"엔코더 설치 오류","en":"Wrong encoder installation"},{"bit":7,"ko":"엔코더 단선","en":"Encoder disconnection"},{"bit":8,"ko":"키패드 상실","en":"Keypad lost"},{"bit":9,"ko":"오토튜닝 실패","en":"Auto tuning failed"},{"bit":10,"ko":"팬 교체","en":"Fan exchange"},{"bit":11,"ko":"화재 모드","en":"Fire mode"},{"bit":15,"ko":"통신 Idle 상태","en":"Comm idle status"}],"ref":"p.303 (PDF 317)"},{"table":"holding-registers","address":895,"manualAddress":"0h0380","type":"u16","name":{"ko":"주파수 지령(확장)","en":"Frequency command (ext.)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.304 (PDF 318)"},{"table":"holding-registers","address":897,"manualAddress":"0h0382","type":"u16","name":{"ko":"운전 지령(확장)","en":"Operation command (ext.)"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"0 정지 / 1 운전","en":"0 stop / 1 run"},{"bit":1,"ko":"0 역방향 / 1 정방향","en":"0 reverse / 1 forward"},{"bit":2,"ko":"트립 리셋(0→1)","en":"Trip reset (0->1)"},{"bit":3,"ko":"프리런 정지(0→1)","en":"Free-run stop (0->1)"}],"description":{"ko":"정방향 운전 0x0003, 역방향 운전 0x0001","en":"Forward run 0x0003, reverse run 0x0001"},"ref":"p.304 (PDF 318)"},{"table":"holding-registers","address":898,"manualAddress":"0h0383","type":"u16","name":{"ko":"가속 시간(확장)","en":"Acceleration time (ext.)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.304 (PDF 318)"},{"table":"holding-registers","address":899,"manualAddress":"0h0384","type":"u16","name":{"ko":"감속 시간(확장)","en":"Deceleration time (ext.)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.304 (PDF 318)"},{"table":"holding-registers","address":991,"manualAddress":"0h03E0","type":"u16","name":{"ko":"파라미터 저장","en":"Save parameters"},"access":"rw","fc":[3,4,6,16],"values":[{"value":0,"ko":"아니오","en":"No"},{"value":1,"ko":"예","en":"Yes"}],"description":{"ko":"0 을 쓴 뒤 1 을 쓰면 저장. 운전 중 변경 불가","en":"Write 0 then 1 to save. Not changeable during run"},"ref":"p.306 (PDF 320)"}],"notes":[{"ko":"통신으로 운전·주파수를 주려면 운전 지령 소스 DRV=3(Int485)·주파수 소스 Frq=6(Int485) 로 둔다 (p.282).","en":"To run and set frequency over RS-485, set DRV = 3 (Int485) and Frq = 6 (Int485) (p.282)."},{"ko":"통신으로 바꾼 공통 영역 값은 전원을 끄면 이전 값으로 돌아간다. 0h03E0 에 0 → 1 을 쓰거나 CNF.48 로 저장 (p.285). 0h0380·0h0005 주파수는 저장해도 남지 않는다 (p.306).","en":"Common-area changes revert at power-off unless saved via 0h03E0 (0 then 1) or CNF.48 (p.285). Frequency written to 0h0380/0h0005 is not retained (p.306)."}],"sources":[{"title":"S100 User Manual (S100_Manual_English_V4.3.pdf) — LSLV-S100","publisher":"LS ELECTRIC","edition":{"ko":"19th Edition, 2026.09 (Revision History p.474); 파일 V4.3","en":"19th Edition, 2026.09 (Revision History p.474); file V4.3"},"url":"https://sftpssqblobcdn.blob.core.windows.net/prod/largefile/document/17912520084750/S100_Manual_English_V4.3.pdf","pages":{"ko":"7장 RS-485 p.279~306 (PDF 293~320), CM 그룹 p.346 (PDF 360)","en":"chapter 7 RS-485 pp.279-306 (PDF 293-320), CM group p.346 (PDF 360)"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"ls-electric/s300","manufacturer":{"ko":"LS일렉트릭","en":"LS ELECTRIC"},"model":"LSLV-S300","models":["S300"],"kind":"inverter","title":{"ko":"LS일렉트릭 S300 인버터 (내장 RS-485)","en":"LS ELECTRIC S300 AC drive (built-in RS-485)"},"summary":{"ko":"내장 RS-485 Modbus-RTU. 확장 공통 영역의 모니터링(0300h~)·제어(0380h~)·트립(0400h~) 영역을 담았다. INTC-06 출하값(1)에서는 프레임 주소 = 매뉴얼 주소 − 1.","en":"Built-in RS-485 Modbus-RTU. Covers the expansion common area: monitoring (0300h-), control (0380h-) and trip (0400h-). With INTC-06 at its default (1), frame address = manual address - 1."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,250],"maxRegisters":16,"addressing":"one","notes":[{"ko":"주소 체계: INTC-06(Modbus Addr Mode) 출하값 1(Yes)에서는 프레임 주소 = 매뉴얼 통신 주소 − 1. 근거: p.454(PDF 488) 예 — 01 03 03 12 00 01 로 읽으면 0311h(출력 주파수, 응답 1770h = 60.00 Hz)가 온다. p.510(PDF 544) FC16 예 — 0383h(가속 시간)에 쓸 때 시작 주소 0382h. INTC-06 = 0(No) 이면 매뉴얼 주소 그대로이므로 address 에 1 을 더해 쓴다.","en":"Addressing: with INTC-06 (Modbus Addr Mode) at its default 1 (Yes), frame address = manual address - 1. Evidence: p.454 (PDF 488) — request 01 03 03 12 00 01 returns 0311h (output frequency, reply 1770h = 60.00 Hz); p.510 (PDF 544) FC16 example writes 0383h (accel time) with start address 0382h. With INTC-06 = 0 (No) the manual address is used as-is, so add 1 to address."},{"ko":"p.454 의 INTC-06 = 0 예는 0312h 를 «출력 전류 1.0 A» 라고 적지만, 확장 공통 영역 표(p.465)에서 0312h 는 출력 rpm, 출력 전류는 0310h 다 — 매뉴얼 안에서 어긋나는 곳(영문판 p.456 도 같음). 출하값(1) 예와 FC16 예는 표와 맞는다.","en":"The INTC-06 = 0 example on p.454 labels 0312h as 'output current 1.0 A', but the table (p.465) lists 0312h as output rpm and 0310h as output current - an inconsistency (same in the English manual p.456). The default-mode example and the FC16 example agree with the table."},{"ko":"초기값: INTC-01 국번 1(1~250), INTC-02 0 Modbus RTU, INTC-03 3 = 9600 bps, INTC-04 0 = D8/PN/S1(8N1·8N2·8E1·8O1 선택), INTC-05 응답 지연 5 ms, INTC-06 1 (p.452~454, PDF 486~488).","en":"Defaults: INTC-01 ID 1 (1-250), INTC-02 0 Modbus RTU, INTC-03 3 = 9600 bps, INTC-04 0 = D8/PN/S1 (8N1/8N2/8E1/8O1), INTC-05 response delay 5 ms, INTC-06 1 (p.452-454, PDF 486-488)."},{"ko":"INTC-03 설정 6 은 «56000bps» 로, 통신 규격표(p.450, PDF 484)에는 57,600 bps 로 적혀 있어 bauds 에서 뺐다.","en":"INTC-03 setting 6 reads '56000bps' while the spec table (p.450, PDF 484) lists 57,600 bps, so it is left out of bauds."},{"ko":"함수 코드 03·04(같게 처리)·06·16, 한 번에 최대 16개. 예외 코드 01·02·03·06·14(Write-Protection) (p.505~509, PDF 539~543). 최대 31대.","en":"Function codes 03/04 (handled the same), 06, 16; up to 16 registers per request. Exception codes 01/02/03/06/14 (write protection) (p.505-509, PDF 539-543). Up to 31 drives."}]},"registers":[{"table":"holding-registers","address":767,"manualAddress":"0300h","type":"u16","name":{"ko":"인버터 모델","en":"Inverter model"},"access":"r","fc":[3,4],"values":[{"value":17,"ko":"S300 (0011h)","en":"S300 (0011h)"}],"ref":"p.462 (PDF 496)"},{"table":"holding-registers","address":768,"manualAddress":"0301h","type":"u16","name":{"ko":"인버터 용량(비트 부호)","en":"Inverter capacity (bit-coded)"},"access":"r","fc":[3,4],"description":{"ko":"B15~B14 단위(0 W, 1 kW, 2 MW), B13~B4 정수부, B3~B0 소수부. 예: 1.5 kW = 4015h, 7.5 kW = 4075h, 400 W = 1900h.","en":"B15-B14 unit (0 W, 1 kW, 2 MW), B13-B4 integer part, B3-B0 fraction. e.g. 1.5 kW = 4015h, 7.5 kW = 4075h, 400 W = 1900h."},"ref":"p.462 (PDF 496)"},{"table":"holding-registers","address":769,"manualAddress":"0302h","type":"u16","name":{"ko":"입력 전압·전원·냉각 방식","en":"Input voltage / phase / cooling"},"access":"r","fc":[3,4],"values":[{"value":561,"ko":"200V급 3상 강냉식","en":"200 V class, 3-phase, forced cooling"},{"value":1073,"ko":"400V급 3상 강냉식","en":"400 V class, 3-phase, forced cooling"}],"ref":"p.463 (PDF 497)"},{"table":"holding-registers","address":770,"manualAddress":"0303h","type":"u16","name":{"ko":"인버터 S/W 버전","en":"Inverter S/W version"},"access":"r","fc":[3,4],"description":{"ko":"16진: 0066h = Version 1.00(매뉴얼 예)","en":"Hex: 0066h = version 1.00 (manual example)"},"ref":"p.463 (PDF 497)"},{"table":"holding-registers","address":772,"manualAddress":"0305h","type":"u16","name":{"ko":"운전 상태","en":"Operating state"},"access":"r","fc":[3,4],"description":{"ko":"B15~B12: 0 트립, 2 경보, 4 운전 비활성, 8 정상. B7~B4: 1 속도 검색, 2 가속, 3 정속, 4 감속, 5 감속 정지, 6 H/W 과전류 억제, 7 S/W 과전류 억제, 8 드웰 운전. B3~B0: 0 정지, 1 정방향, 2 역방향, 3 DC 운전.","en":"B15-B12: 0 trip, 2 warning, 4 run disabled, 8 normal. B7-B4: 1 speed search, 2 accelerating, 3 steady, 4 decelerating, 5 decel to stop, 6 H/W overcurrent suppression, 7 S/W overcurrent suppression, 8 dwell. B3-B0: 0 stop, 1 forward, 2 reverse, 3 DC operation."},"ref":"p.463 (PDF 497)"},{"table":"holding-registers","address":773,"manualAddress":"0306h","type":"u16","name":{"ko":"운전·주파수 지령 소스","en":"Run / frequency command source"},"access":"r","fc":[3,4],"description":{"ko":"B15~B8 운전 지령 소스: 0 Smart Operator, 1 통신 옵션, 3 내장 RS485, 4 단자대, 5 USB. B7~B0 주파수 지령 소스: 0 Smart Operator 속도, 1 Smart Operator 토크, 2~4 업/다운, 5 AI1, 6 AI2, 7 AI3, 9 펄스, 10 내장 RS485, 11 통신 옵션, 13 조그, 14 PID, 15 USB, 25 다단속.","en":"B15-B8 run source: 0 Smart Operator, 1 comm option, 3 built-in RS485, 4 terminal, 5 USB. B7-B0 frequency source: 0 Smart Operator speed, 1 Smart Operator torque, 2-4 up/down, 5 AI1, 6 AI2, 7 AI3, 9 pulse, 10 built-in RS485, 11 comm option, 13 jog, 14 PID, 15 USB, 25 multi-step."},"ref":"p.464 (PDF 498)"},{"table":"holding-registers","address":783,"manualAddress":"0310h","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.1,"access":"r","fc":[3,4],"ref":"p.465 (PDF 499)"},{"table":"holding-registers","address":784,"manualAddress":"0311h","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3,4],"ref":"p.465 (PDF 499)"},{"table":"holding-registers","address":787,"manualAddress":"0314h","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":1,"access":"r","fc":[3,4],"ref":"p.465 (PDF 499)"},{"table":"holding-registers","address":788,"manualAddress":"0315h","type":"u16","name":{"ko":"DC 링크 전압","en":"DC link voltage"},"unit":"V","scale":1,"access":"r","fc":[3,4],"ref":"p.465 (PDF 499)"},{"table":"holding-registers","address":789,"manualAddress":"0316h","type":"u16","name":{"ko":"출력 파워","en":"Output power"},"unit":"kW","scale":0.1,"access":"r","fc":[3,4],"ref":"p.465 (PDF 499)"},{"table":"holding-registers","address":790,"manualAddress":"0317h","type":"u16","name":{"ko":"출력 토크","en":"Output torque"},"unit":"%","scale":0.1,"access":"r","fc":[3,4],"ref":"p.465 (PDF 499)"},{"table":"holding-registers","address":799,"manualAddress":"0320h","type":"u16","name":{"ko":"디지털 입력 상태","en":"Digital input status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"DI1","en":"DI1"},{"bit":1,"ko":"DI2","en":"DI2"},{"bit":2,"ko":"DI3","en":"DI3"},{"bit":3,"ko":"DI4","en":"DI4"},{"bit":4,"ko":"DI5","en":"DI5"},{"bit":5,"ko":"DI6","en":"DI6"},{"bit":6,"ko":"DI7","en":"DI7"},{"bit":7,"ko":"DI8","en":"DI8"}],"ref":"p.466~467 (PDF 500~501)"},{"table":"holding-registers","address":800,"manualAddress":"0321h","type":"u16","name":{"ko":"디지털 출력 상태","en":"Digital output status"},"access":"r","fc":[3,4],"bits":[{"bit":0,"ko":"DO1","en":"DO1"},{"bit":1,"ko":"DO2","en":"DO2"},{"bit":2,"ko":"DO3","en":"DO3"}],"ref":"p.467 (PDF 501)"},{"table":"holding-registers","address":803,"manualAddress":"0324h","type":"u16","name":{"ko":"아날로그 입력 1 (V1, I1)","en":"Analog input 1 (V1, I1)"},"unit":"%","scale":0.01,"access":"r","fc":[3,4],"ref":"p.468 (PDF 502)"},{"table":"holding-registers","address":804,"manualAddress":"0325h","type":"u16","name":{"ko":"아날로그 입력 2 (V2, I2)","en":"Analog input 2 (V2, I2)"},"unit":"%","scale":0.01,"access":"r","fc":[3,4],"ref":"p.468 (PDF 502)"},{"table":"holding-registers","address":805,"manualAddress":"0326h","type":"u16","name":{"ko":"아날로그 입력 3 (V3, I3)","en":"Analog input 3 (V3, I3)"},"unit":"%","scale":0.01,"access":"r","fc":[3,4],"ref":"p.468 (PDF 502)"},{"table":"holding-registers","address":807,"manualAddress":"0328h","type":"u16","name":{"ko":"아날로그 출력 1","en":"Analog output 1"},"unit":"%","scale":0.01,"access":"r","fc":[3,4],"ref":"p.468 (PDF 502)"},{"table":"holding-registers","address":812,"manualAddress":"032Dh","type":"u16","name":{"ko":"온도(NTC)","en":"Temperature (NTC)"},"unit":"℃","scale":1,"access":"r","fc":[3,4],"ref":"p.468 (PDF 502)"},{"table":"holding-registers","address":813,"manualAddress":"032Eh","type":"u16","name":{"ko":"전력 소비량(kWh 자리)","en":"Energy consumption (kWh part)"},"unit":"kWh","access":"r","fc":[3,4],"description":{"ko":"032Fh(MWh 자리)와 함께 읽는다. 스케일 칸은 «-».","en":"Read together with 032Fh (MWh part). Scale cell is '-'."},"ref":"p.469 (PDF 503)"},{"table":"holding-registers","address":814,"manualAddress":"032Fh","type":"u16","name":{"ko":"전력 소비량(MWh 자리)","en":"Energy consumption (MWh part)"},"unit":"MWh","access":"r","fc":[3,4],"ref":"p.469 (PDF 503)"},{"table":"holding-registers","address":895,"manualAddress":"0380h","type":"u16","name":{"ko":"주파수 지령","en":"Frequency command"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,4,6,16],"ref":"p.471 (PDF 505)"},{"table":"holding-registers","address":896,"manualAddress":"0381h","type":"u16","name":{"ko":"rpm 지령","en":"Speed command (rpm)"},"unit":"rpm","scale":1,"access":"rw","fc":[3,4,6,16],"ref":"p.471 (PDF 505)"},{"table":"holding-registers","address":897,"manualAddress":"0382h","type":"u16","name":{"ko":"운전 지령","en":"Run command"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"운전","en":"Run"},{"bit":1,"ko":"방향(0 역방향, 1 정방향)","en":"Direction (0 reverse, 1 forward)"},{"bit":2,"ko":"트립 리셋","en":"Trip reset"},{"bit":3,"ko":"프리 런 정지","en":"Free-run stop"}],"ref":"p.471 (PDF 505)"},{"table":"holding-registers","address":898,"manualAddress":"0383h","type":"u16","name":{"ko":"가속 시간","en":"Acceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.471 (PDF 505)"},{"table":"holding-registers","address":899,"manualAddress":"0384h","type":"u16","name":{"ko":"감속 시간","en":"Deceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.471 (PDF 505)"},{"table":"holding-registers","address":900,"manualAddress":"0385h","type":"u16","name":{"ko":"가상 디지털 입력 제어","en":"Virtual digital input control"},"access":"rw","fc":[3,4,6,16],"bits":[{"bit":0,"ko":"Virtual DI1","en":"Virtual DI1"},{"bit":1,"ko":"Virtual DI2","en":"Virtual DI2"},{"bit":2,"ko":"Virtual DI3","en":"Virtual DI3"},{"bit":3,"ko":"Virtual DI4","en":"Virtual DI4"},{"bit":4,"ko":"Virtual DI5","en":"Virtual DI5"},{"bit":5,"ko":"Virtual DI6","en":"Virtual DI6"},{"bit":6,"ko":"Virtual DI7","en":"Virtual DI7"},{"bit":7,"ko":"Virtual DI8","en":"Virtual DI8"},{"bit":8,"ko":"Virtual DI9","en":"Virtual DI9"},{"bit":9,"ko":"Virtual DI10","en":"Virtual DI10"},{"bit":10,"ko":"Virtual DI11","en":"Virtual DI11"},{"bit":11,"ko":"Virtual DI12","en":"Virtual DI12"},{"bit":12,"ko":"Virtual DI13","en":"Virtual DI13"},{"bit":13,"ko":"Virtual DI14","en":"Virtual DI14"},{"bit":14,"ko":"Virtual DI15","en":"Virtual DI15"},{"bit":15,"ko":"Virtual DI16","en":"Virtual DI16"}],"description":{"ko":"비트마다 0 Off, 1 On.","en":"Per bit: 0 Off, 1 On."},"ref":"p.472 (PDF 506)"},{"table":"holding-registers","address":903,"manualAddress":"0388h","type":"u16","name":{"ko":"PID 레퍼런스","en":"PID reference"},"unit":"%","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.473 (PDF 507)"},{"table":"holding-registers","address":904,"manualAddress":"0389h","type":"u16","name":{"ko":"PID 피드백값","en":"PID feedback"},"unit":"%","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.473 (PDF 507)"},{"table":"holding-registers","address":911,"manualAddress":"0390h","type":"u16","name":{"ko":"토크 지령","en":"Torque command"},"unit":"%","scale":0.1,"access":"rw","fc":[3,4,6,16],"ref":"p.473 (PDF 507)"},{"table":"holding-registers","address":1023,"manualAddress":"0400h","type":"u16","name":{"ko":"현재 트립 1 인덱스","en":"Current trip 1 index"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"ADC Offset","en":"ADC Offset"},{"value":1,"ko":"Watchdog","en":"Watchdog"},{"value":2,"ko":"Gate Power Loss","en":"Gate Power Loss"},{"value":3,"ko":"Main OS Error","en":"Main OS Error"},{"value":4,"ko":"Over Load","en":"Over Load"},{"value":5,"ko":"Under Load","en":"Under Load"},{"value":6,"ko":"Inverter Over Load","en":"Inverter Over Load"},{"value":7,"ko":"E-Thermal","en":"E-Thermal"},{"value":8,"ko":"Ground Fault","en":"Ground Fault"},{"value":9,"ko":"Out Phase U Open","en":"Out Phase U Open"},{"value":10,"ko":"In Phase Open","en":"In Phase Open"},{"value":11,"ko":"Over Speed","en":"Over Speed"},{"value":12,"ko":"Speed Deviation","en":"Speed Deviation"},{"value":13,"ko":"Drv Over Heat","en":"Drv Over Heat"},{"value":14,"ko":"NTC Open","en":"NTC Open"},{"value":15,"ko":"NTC Short","en":"NTC Short"},{"value":16,"ko":"Over Current","en":"Over Current"},{"value":17,"ko":"Over Voltage","en":"Over Voltage"},{"value":18,"ko":"IO Board","en":"IO Board"},{"value":19,"ko":"BX","en":"BX"},{"value":20,"ko":"Mechanical Brake","en":"Mechanical Brake"},{"value":21,"ko":"External 1","en":"External 1"},{"value":22,"ko":"External 2","en":"External 2"},{"value":23,"ko":"External 3","en":"External 3"},{"value":24,"ko":"External 4","en":"External 4"},{"value":25,"ko":"Arm Short","en":"Arm Short"},{"value":26,"ko":"Fuse Open","en":"Fuse Open"},{"value":27,"ko":"Encoder","en":"Encoder"},{"value":28,"ko":"Encoder No Connection","en":"Encoder No Connection"},{"value":29,"ko":"Encoder Wrong Dir","en":"Encoder Wrong Dir"},{"value":30,"ko":"Motor Over Heat","en":"Motor Over Heat"},{"value":31,"ko":"Main Fan Fault","en":"Main Fan Fault"},{"value":32,"ko":"Parameter Write","en":"Parameter Write"},{"value":33,"ko":"Pre PID Fail","en":"Pre PID Fail"},{"value":34,"ko":"No Motor","en":"No Motor"},{"value":35,"ko":"Option 1","en":"Option 1"},{"value":36,"ko":"Option 2","en":"Option 2"},{"value":37,"ko":"Option 3","en":"Option 3"},{"value":38,"ko":"Low Voltage","en":"Low Voltage"},{"value":39,"ko":"Lost Sensor","en":"Lost Sensor"},{"value":40,"ko":"Lost Int Comm","en":"Lost Int Comm"},{"value":41,"ko":"Lost Opt Comm","en":"Lost Opt Comm"},{"value":42,"ko":"Lost Keypad","en":"Lost Keypad"},{"value":43,"ko":"Lost USB","en":"Lost USB"},{"value":44,"ko":"Lost AI 1","en":"Lost AI 1"},{"value":45,"ko":"Lost AI 2","en":"Lost AI 2"},{"value":46,"ko":"Lost AI 3","en":"Lost AI 3"},{"value":47,"ko":"Lost AI 4","en":"Lost AI 4"},{"value":48,"ko":"Lost Ext AI 1","en":"Lost Ext AI 1"},{"value":49,"ko":"Lost Ext AI 2","en":"Lost Ext AI 2"},{"value":50,"ko":"Lost Ext AI 3","en":"Lost Ext AI 3"},{"value":51,"ko":"Lost Ext AI 4","en":"Lost Ext AI 4"},{"value":52,"ko":"STO Feedback A","en":"STO Feedback A"},{"value":53,"ko":"STO Feedback B","en":"STO Feedback B"},{"value":54,"ko":"STO P24 Fault","en":"STO P24 Fault"},{"value":55,"ko":"STO P5 Fault","en":"STO P5 Fault"},{"value":56,"ko":"Aux Fan Fault","en":"Aux Fan Fault"},{"value":57,"ko":"Control Fan Fault","en":"Control Fan Fault"},{"value":58,"ko":"Data Storage","en":"Data Storage"},{"value":59,"ko":"Precharge Fail","en":"Precharge Fail"},{"value":60,"ko":"H/W OCS Fail","en":"H/W OCS Fail"},{"value":61,"ko":"TR Tune Fail","en":"TR Tune Fail"},{"value":62,"ko":"RS Tune Fail","en":"RS Tune Fail"},{"value":63,"ko":"SLS Tune Fail","en":"SLS Tune Fail"},{"value":64,"ko":"LS Tune Fail","en":"LS Tune Fail"},{"value":65,"ko":"IF Tune Fail","en":"IF Tune Fail"},{"value":66,"ko":"MC Fault","en":"MC Fault"},{"value":67,"ko":"Reserved","en":"Reserved"},{"value":68,"ko":"Lost P24V","en":"Lost P24V"},{"value":69,"ko":"Out Phase V Open","en":"Out Phase V Open"},{"value":70,"ko":"Out Phase W Open","en":"Out Phase W Open"},{"value":71,"ko":"Reset/Restart Fail","en":"Reset/Restart Fail"},{"value":72,"ko":"Outline Short","en":"Outline Short"},{"value":73,"ko":"KEB Safety Stop","en":"KEB Safety Stop"},{"value":74,"ko":"System Error-1","en":"System Error-1"},{"value":75,"ko":"Br Release Invalid","en":"Br Release Invalid"},{"value":76,"ko":"Br Releasing Fail","en":"Br Releasing Fail"},{"value":77,"ko":"Br Engaging Fail","en":"Br Engaging Fail"},{"value":78,"ko":"Main Cap Diag Fail","en":"Main Cap Diag Fail"},{"value":79,"ko":"Encoder Tuning Err","en":"Encoder Tuning Err"},{"value":80,"ko":"Pole Pos Detect F","en":"Pole Pos Detect F"},{"value":81,"ko":"Pos Max Track Err","en":"Pos Max Track Err"},{"value":82,"ko":"Pos Tar Bound Err","en":"Pos Tar Bound Err"},{"value":83,"ko":"Pos SW Limit High","en":"Pos SW Limit High"},{"value":84,"ko":"Pos SW Limit Low","en":"Pos SW Limit Low"},{"value":85,"ko":"Pos HW Limit High","en":"Pos HW Limit High"},{"value":86,"ko":"Pos HW Limit Low","en":"Pos HW Limit Low"},{"value":87,"ko":"Pos Multi Sync F","en":"Pos Multi Sync F"},{"value":88,"ko":"Cur Pos Overf Err","en":"Cur Pos Overf Err"},{"value":89,"ko":"Power Index Error","en":"Power Index Error"},{"value":90,"ko":"CAN Bus Error","en":"CAN Bus Error"},{"value":91,"ko":"Prevent Cmd Trip","en":"Prevent Cmd Trip"},{"value":92,"ko":"WebBreak Trip","en":"WebBreak Trip"},{"value":93,"ko":"Ambient Sensor Flt","en":"Ambient Sensor Flt"},{"value":94,"ko":"Ambient Over Heat","en":"Ambient Over Heat"},{"value":95,"ko":"Ambient Under Heat","en":"Ambient Under Heat"},{"value":96,"ko":"Ana In Lvl Detect","en":"Ana In Lvl Detect"},{"value":97,"ko":"RP Wire Error","en":"RP Wire Error"},{"value":65535,"ko":"없음(FFFFh)","en":"None (FFFFh)"}],"description":{"ko":"트립 모드 영역(읽기 전용).","en":"Trip mode area (read-only)."},"ref":"p.477~480 (PDF 511~514)"},{"table":"holding-registers","address":1024,"manualAddress":"0401h","type":"u16","name":{"ko":"현재 트립 2 인덱스","en":"Current trip 2 index"},"access":"r","fc":[3,4],"description":{"ko":"값의 뜻은 0400h 와 같다.","en":"Same codes as 0400h."},"ref":"p.480 (PDF 514)"},{"table":"holding-registers","address":1030,"manualAddress":"0407h","type":"u16","name":{"ko":"트립 직전 인버터 상태","en":"Drive state before trip"},"access":"r","fc":[3,4],"values":[{"value":0,"ko":"정지","en":"Stop"},{"value":1,"ko":"0속 운전","en":"Zero-speed run"},{"value":2,"ko":"가속 운전","en":"Accelerating"},{"value":3,"ko":"감속 운전","en":"Decelerating"},{"value":4,"ko":"정속 운전","en":"Steady speed"},{"value":5,"ko":"토크 운전","en":"Torque run"}],"ref":"p.481 (PDF 515)"}],"notes":[{"ko":"통신으로 운전·주파수를 주려면 DRV-10 = 4(Internal Comm.), DRV-11 = 6(Internal Comm.) (p.455, PDF 489).","en":"Set DRV-10 = 4 (Internal Comm.) and DRV-11 = 6 (Internal Comm.) to command over RS-485 (p.455, PDF 489)."},{"ko":"매뉴얼 표에는 R/W 칸이 없다. 0300h~ 은 «모니터링 영역», 0380h~ 은 «인버터 제어 영역», 0400h~ 은 «트립 모드 영역(읽기 전용)» 이라는 절 이름에 따라 r·rw·r 로 두었다.","en":"The manual's tables have no R/W column. Access follows the section titles: 0300h- 'monitoring area' (r), 0380h- 'inverter control area' (rw), 0400h- 'trip mode area (read-only)' (r)."},{"ko":"스케일 칸이 «-»·«0» 으로 적힌 항목(목표값 030Ah~030Fh, 출력 rpm 0312h, 누적 시간 0340h~ 등)과 R/W 칸 없는 호환 공통 영역(0000h~)은 넣지 않았다.","en":"Entries whose scale cell is '-' or '0' (target values 030Ah-030Fh, output rpm 0312h, run-time counters 0340h- etc.) and the compatible common area (0000h-, no R/W column) are omitted."}],"sources":[{"title":"LSLV-S300 Series 사용 설명서 (S300_User Manual_Standard_V1.9_260903_KR.pdf)","publisher":"LS ELECTRIC","edition":{"ko":"V1.9, 2026-09-03 (개정 이력 p.820)","en":"V1.9, 2026-09-03 (revision history p.820)"},"url":"https://sftpssqblobcdn.blob.core.windows.net/prod/largefile/document/17889361069280/S300_User%20Manual_Standard_V1.9_260903_KR.pdf","pages":{"ko":"10장 통신 기능 p.450~481 (PDF 484~515), 통신 예 p.510 (PDF 544)","en":"chapter 10 communication pp.450-481 (PDF 484-515), example p.510 (PDF 544)"},"checked":"2026-10-23"},{"title":"LSLV-S300 Series User Manual (S300_User Manual_Standard_V1.8_260903_EN.pdf)","publisher":"LS ELECTRIC","edition":{"ko":"영문 V1.8, 2026-09-03","en":"English V1.8, 2026-09-03"},"url":"https://sftpssqblobcdn.blob.core.windows.net/prod/largefile/document/17889364652080/S300_User%20Manual_Standard_V1.8_260903_EN.pdf","pages":{"ko":"INTC-06 예 p.456 (PDF 490), 확장 공통 영역 p.464~ (PDF 498~), FC16 예 p.512 (PDF 546) — 국문판과 대조용","en":"INTC-06 example p.456 (PDF 490), expansion common area p.464- (PDF 498-), FC16 example p.512 (PDF 546) - cross-check"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-a700","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-A700","models":["FR-A720-0.4K~90K","FR-A740-0.4K~500K"],"kind":"inverter","title":{"ko":"미쓰비시전기 FR-A700 인버터 (RS-485 단자 Modbus RTU)","en":"Mitsubishi Electric FR-A700 inverter (RS-485 terminals Modbus RTU)"},"summary":{"ko":"RS-485 단자 Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~40508, 파라미터 41000+번호","en":"RS-485 terminals Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-40508, parameters 41000 + number"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[300,600,1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.350 (PDF 361))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고(응답 … 17 70 0B B8 03 E8 2C E6 = 60·30·10 Hz), 쓰기 예(p.351 (PDF 362))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.353 (PDF 364))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.350 (PDF 361)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6) (reply ... 17 70 0B B8 03 E8 2C E6 = 60/30/10 Hz); the write example (p.351 (PDF 362)) 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.353 (PDF 364)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). RS-485 단자 쪽 설정이다: Pr.331 국번 초기값 0 은 브로드캐스트라 응답이 없으니 1~247 로, Pr.332 초기값 96 = 9600 bps, Pr.334 초기값 2 = 짝수 패리티·정지 1비트, 데이터 8비트 고정 (p.346-347 (PDF 357-358)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). These are the RS-485 terminal settings: Pr.331 station default 0 is broadcast (no reply), so set 1-247; Pr.332 default 96 = 9600 bps; Pr.334 default 2 = even parity, 1 stop bit; 8 data bits fixed (pp.346-347 (PDF 357-358))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기·쓰기. 통신 옵션이 달려 있고 Pr.550 = 9999(초기값)이면 RS-485 단자의 운전 명령은 무효.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read/write. With a communication option installed and Pr.550 = 9999 (initial), operation commands via the RS-485 terminals are invalid."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.355 (PDF 366)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하)","en":"Write: RM (middle speed) / Read: OL (overload)"},{"bit":5,"ko":"쓰기: RL(저속) / 읽기: IPF(순간 정전)","en":"Write: RL (low speed) / Read: IPF (instantaneous power failure)"},{"bit":6,"ko":"쓰기: JOG(조그) / 읽기: FU(주파수 검출)","en":"Write: JOG (jog) / Read: FU (frequency detection)"},{"bit":7,"ko":"쓰기: RT(제2 기능) / 읽기: ABC1(고장)","en":"Write: RT (second function) / Read: ABC1 (fault)"},{"bit":8,"ko":"쓰기: AU(전류 입력 선택) / 읽기: ABC2","en":"Write: AU (current input selection) / Read: ABC2"},{"bit":9,"ko":"쓰기: CS(순간 정전 후 재시동 선택)","en":"Write: CS (automatic restart after instantaneous power failure)"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":11,"ko":"쓰기: STOP(기동 자기유지)","en":"Write: STOP (start self-holding)"},{"bit":12,"ko":"쓰기: RES(리셋)","en":"Write: RES (reset)"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~189, 출력은 Pr.190~196 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in parentheses are initial assignments; inputs follow Pr.180-189, outputs Pr.190-196"},"ref":"p.355 (PDF 366)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU(Pr.79·Pr.340 에 따라), 0014h = NET","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU (depending on Pr.79/Pr.340), 0014h = NET"},"ref":"p.355 (PDF 366)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"설정 주파수(RAM)","en":"Set frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37·Pr.144 에 따라 회전 속도(r/min) 단위로 바뀐다. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Changes to r/min units depending on Pr.37/Pr.144. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.355 (PDF 366)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"설정 주파수(EEPROM)","en":"Set frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.355 (PDF 366)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 4)에서 0.01 Hz. Pr.37·Pr.144 조합에 따라 회전 속도(r/min)·기계 속도(1 단위)로 바뀐다(p.252 (PDF 263))","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 4); changes to r/min or machine speed (increment 1) depending on Pr.37/Pr.144 (p.252 (PDF 263))"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-A720-55K·FR-A740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-A720-55K·FR-A740-55K); 0.1 for 75K or higher"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 4)에서 0.01 Hz. Pr.37·Pr.144 조합에 따라 회전 속도(r/min)·기계 속도(1 단위)로 바뀐다(p.252 (PDF 263))","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 4); changes to r/min or machine speed (increment 1) depending on Pr.37/Pr.144 (p.252 (PDF 263))"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":205,"manualAddress":"40206","type":"u16","name":{"ko":"운전 속도","en":"Running speed"},"unit":"r/min","access":"r","fc":[3],"description":{"ko":"1 r/min 단위. Pr.811 = 1·11 이면 0.1 r/min(p.251 (PDF 262))","en":"1 r/min increments; 0.1 r/min when Pr.811 = 1 or 11 (p.251 (PDF 262))"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":206,"manualAddress":"40207","type":"u16","name":{"ko":"모터 토크","en":"Motor torque"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 사용률","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal relay function load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크값","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-A720-55K·FR-A740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-A720-55K·FR-A740-55K); 0.1 for 75K or higher"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":211,"manualAddress":"40212","type":"u16","name":{"ko":"컨버터 출력 전압 피크값","en":"Converter output voltage peak value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":212,"manualAddress":"40213","type":"u16","name":{"ko":"입력 전력","en":"Input power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-A720-55K·FR-A740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-A720-55K·FR-A740-55K); 0.1 for 75K or higher"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-A720-55K·FR-A740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-A720-55K·FR-A740-55K); 0.1 for 75K or higher"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":2,"ko":"AU","en":"AU"},{"bit":3,"ko":"RT","en":"RT"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"},{"bit":7,"ko":"JOG","en":"JOG"},{"bit":8,"ko":"MRS","en":"MRS"},{"bit":9,"ko":"STOP","en":"STOP"},{"bit":10,"ko":"RES","en":"RES"},{"bit":11,"ko":"CS","en":"CS"}],"description":{"ko":"1 = ON. 다른 비트는 정해지지 않은 값","en":"1 = ON. Other bits are undetermined"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":1,"ko":"SU","en":"SU"},{"bit":2,"ko":"IPF","en":"IPF"},{"bit":3,"ko":"OL","en":"OL"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC1","en":"ABC1"},{"bit":6,"ko":"ABC2","en":"ABC2"}],"description":{"ko":"1 = ON. 다른 비트는 정해지지 않은 값","en":"1 = ON. Other bits are undetermined"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":216,"manualAddress":"40217","type":"u16","name":{"ko":"로드 미터","en":"Load meter"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":217,"manualAddress":"40218","type":"u16","name":{"ko":"모터 여자 전류","en":"Motor excitation current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-A720-55K·FR-A740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-A720-55K·FR-A740-55K); 0.1 for 75K or higher"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.563)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.563)"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.564)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.564)"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":224,"manualAddress":"40225","type":"u16","name":{"ko":"누적 전력량","en":"Cumulative power"},"unit":"kWh","access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":231,"manualAddress":"40232","type":"u16","name":{"ko":"토크 지령","en":"Torque command"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":232,"manualAddress":"40233","type":"u16","name":{"ko":"토크 전류 지령","en":"Torque current command"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":233,"manualAddress":"40234","type":"u16","name":{"ko":"모터 출력","en":"Motor output"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-A720-55K·FR-A740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-A720-55K·FR-A740-55K); 0.1 for 75K or higher"},"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":251,"manualAddress":"40252","type":"u16","name":{"ko":"PID 목표값","en":"PID set point"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":252,"manualAddress":"40253","type":"u16","name":{"ko":"PID 측정값","en":"PID measured value"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":253,"manualAddress":"40254","type":"u16","name":{"ko":"PID 편차","en":"PID deviation"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.356 (PDF 367)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault history 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh). Writing any value clears the whole fault history"},"ref":"p.358 (PDF 369)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault history 2"},"access":"r","fc":[3],"description":{"ko":"40508(고장 이력 8)까지 같은 형식","en":"Same format up to 40508 (fault history 8)"},"ref":"p.358 (PDF 369)","source":0},{"table":"holding-registers","address":1003,"manualAddress":"41004","type":"u16","name":{"ko":"다단 속도 고속(Pr.4)","en":"Multi-speed setting, high speed (Pr.4)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 1770h = 60.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 1770h = 60.00 Hz"},"ref":"p.350 (PDF 361)","source":0},{"table":"holding-registers","address":1004,"manualAddress":"41005","type":"u16","name":{"ko":"다단 속도 중속(Pr.5)","en":"Multi-speed setting, middle speed (Pr.5)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 0BB8h = 30.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 0BB8h = 30.00 Hz"},"ref":"p.350 (PDF 361)","source":0},{"table":"holding-registers","address":1005,"manualAddress":"41006","type":"u16","name":{"ko":"다단 속도 저속(Pr.6)","en":"Multi-speed setting, low speed (Pr.6)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 03E8h = 10.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 03E8h = 10.00 Hz"},"ref":"p.350 (PDF 361)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s(p.172 (PDF 183)). 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1 (p.172 (PDF 183)). Manual FC10 example: 0.5 s = 0005h"},"ref":"p.353 (PDF 364)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 1 s = 000Ah"},"ref":"p.353 (PDF 364)","source":0}],"notes":[{"ko":"전류·전력 배율은 55K 이하 기준(scale 0.01). 75K 이상은 0.1 단위다. 누적 전력량(40225)은 1 kWh 단위.","en":"Current and power scales are for 55K or lower (scale 0.01); 75K or higher use 0.1 increments. Cumulative power (40225) is in 1 kWh."},{"ko":"단자 비트는 초기 할당 기준. 제조 시기에 따라 사양이 다른 항목(Ver.UP 표시)은 넣지 않았다.","en":"Terminal bits are for the initial assignments. Items marked Ver.UP (specifications differ by assembly date) are not included."}],"sources":[{"title":"FR-A700 INSTRUCTION MANUAL (Applied)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600226ENG-E","en":"IB(NA)-0600226ENG-E"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600226eng/ib0600226enge.pdf","pages":{"ko":"Modbus-RTU p.346 (PDF 357)~p.358 (PDF 369), Pr.37·Pr.144 p.251-252 (PDF 262-263), Pr.7·Pr.21 p.172 (PDF 183)","en":"Modbus-RTU p.346 (PDF 357) to p.358 (PDF 369), Pr.37/Pr.144 pp.251-252 (PDF 262-263), Pr.7/Pr.21 p.172 (PDF 183)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-a800","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-A800","kind":"inverter","title":{"ko":"미쓰비시전기 FR-A800 인버터 (RS-485 단자 Modbus RTU)","en":"Mitsubishi Electric FR-A800 inverter (RS-485 terminals Modbus RTU)"},"summary":{"ko":"RS-485 단자 Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~40508, 파라미터 41000+번호, 형명·용량 44001~","en":"RS-485 terminals Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-40508, parameters 41000 + number, model and capacity 44001-"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[300,600,1200,2400,4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.719 (PDF 720))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고, 쓰기 예(p.720 (PDF 721))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.721 (PDF 722))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.719 (PDF 720)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6); the write example (p.720 (PDF 721)) 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.721 (PDF 722)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). PU 커넥터가 아니라 RS-485 단자 쪽 설정이다: Pr.331 국번 초기값 0 은 브로드캐스트라 응답이 없으니 1~247 로, Pr.332 초기값 96 = 9600 bps, Pr.334 초기값 2 = 짝수 패리티·정지 1비트(Pr.333 정지 비트는 Pr.334 = 0 일 때만), 데이터 8비트 고정 (p.715-716 (PDF 716-717)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). These are the RS-485 terminal settings, not the PU connector: Pr.331 station default 0 is broadcast (no reply), so set 1-247; Pr.332 default 96 = 9600 bps; Pr.334 default 2 = even parity, 1 stop bit (Pr.333 stop bits apply only when Pr.334 = 0); 8 data bits fixed (p.715-716 (PDF 716-717))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기·쓰기. 통신 옵션이 달려 있고 Pr.550 = 9999(초기값)이면 RS-485 단자의 운전 명령은 무효.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read/write. With a communication option installed and Pr.550 = 9999 (initial), operation commands via the RS-485 terminals are invalid."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.723 (PDF 724)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하 경보)","en":"Write: RM (middle speed) / Read: OL (overload warning)"},{"bit":5,"ko":"쓰기: RL(저속) / 읽기: IPF(순간 정전/부족 전압)","en":"Write: RL (low speed) / Read: IPF (instantaneous power failure/undervoltage)"},{"bit":6,"ko":"쓰기: JOG(조그 운전) / 읽기: FU(주파수 검출)","en":"Write: JOG (jog operation) / Read: FU (frequency detection)"},{"bit":7,"ko":"쓰기: RT(제2 기능 선택) / 읽기: ABC1(고장)","en":"Write: RT (second function selection) / Read: ABC1 (fault)"},{"bit":8,"ko":"쓰기: AU(단자 4 입력 선택) / 읽기: ABC2","en":"Write: AU (terminal 4 input selection) / Read: ABC2"},{"bit":9,"ko":"쓰기: CS(순간 정전 후 자동 재시동 선택) / 읽기: 안전 모니터 출력","en":"Write: CS (automatic restart after instantaneous power failure) / Read: Safety monitor output"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":11,"ko":"쓰기: STP(STOP, 기동 자기 유지)","en":"Write: STP (STOP, start self-holding)"},{"bit":12,"ko":"쓰기: RES(리셋)","en":"Write: RES (inverter reset)"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~189, 출력은 Pr.190~196 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in brackets are initial assignments; inputs change with Pr.180-189, outputs with Pr.190-196"},"ref":"p.724 (PDF 725)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU(Pr.79·Pr.340 에 따라), 0014h = NET","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU (depending on Pr.79/Pr.340), 0014h = NET"},"ref":"p.724 (PDF 725)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"설정 주파수(RAM)","en":"Set frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 2~12)에서 0.01 Hz. Pr.37·Pr.144 에 따라 회전 속도·기계 속도(1 단위)로 바뀐다. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 2-12); changes to rotation/machine speed (increment 1) depending on Pr.37/Pr.144. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.723 (PDF 724)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"설정 주파수(EEPROM)","en":"Set frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.723 (PDF 724)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 2~12)에서 0.01 Hz. Pr.37·Pr.144 에 따라 회전 속도·기계 속도(1 단위)로 바뀐다","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 2-12); changes to rotation/machine speed (increment 1) depending on Pr.37/Pr.144"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-A820-03160(55K)·FR-A840-01800(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-A820-03160 (55K) / FR-A840-01800 (55K) or lower; 0.1 for larger capacities"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 2~12)에서 0.01 Hz. Pr.37·Pr.144 에 따라 회전 속도·기계 속도(1 단위)로 바뀐다","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 2-12); changes to rotation/machine speed (increment 1) depending on Pr.37/Pr.144"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":205,"manualAddress":"40206","type":"u16","name":{"ko":"운전 속도","en":"Operation speed"},"unit":"r/min","access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":206,"manualAddress":"40207","type":"u16","name":{"ko":"모터 토크","en":"Motor torque"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 사용률","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal O/L relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크값","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-A820-03160(55K)·FR-A840-01800(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-A820-03160 (55K) / FR-A840-01800 (55K) or lower; 0.1 for larger capacities"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":211,"manualAddress":"40212","type":"u16","name":{"ko":"컨버터 출력 전압 피크값","en":"Converter output voltage peak value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":212,"manualAddress":"40213","type":"u16","name":{"ko":"입력 전력","en":"Input power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-A820-03160(55K)·FR-A840-01800(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-A820-03160 (55K) / FR-A840-01800 (55K) or lower; 0.1 for larger capacities"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-A820-03160(55K)·FR-A840-01800(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-A820-03160 (55K) / FR-A840-01800 (55K) or lower; 0.1 for larger capacities"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":2,"ko":"AU","en":"AU"},{"bit":3,"ko":"RT","en":"RT"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"},{"bit":7,"ko":"JOG","en":"JOG"},{"bit":8,"ko":"MRS","en":"MRS"},{"bit":9,"ko":"STP (STOP)","en":"STP (STOP)"},{"bit":10,"ko":"RES","en":"RES"},{"bit":11,"ko":"CS","en":"CS"},{"bit":14,"ko":"S2","en":"S2"},{"bit":15,"ko":"S1","en":"S1"}],"ref":"p.467-468 (PDF 468-469)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":1,"ko":"SU","en":"SU"},{"bit":2,"ko":"IPF","en":"IPF"},{"bit":3,"ko":"OL","en":"OL"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC1","en":"ABC1"},{"bit":6,"ko":"ABC2","en":"ABC2"},{"bit":7,"ko":"SO","en":"SO"}],"ref":"p.467-468 (PDF 468-469)","source":0},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.563)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.563)"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.564)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.564)"},"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.464-465 (PDF 465-466)","source":0},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.467 (PDF 468)","source":0},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.467 (PDF 468)","source":0},{"table":"holding-registers","address":276,"manualAddress":"40277","type":"u32","order":"CDAB","name":{"ko":"32비트 누적 전력량(kWh)","en":"32-bit cumulative energy (kWh)"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"40277 = 하위 16비트, 40278 = 상위 16비트(워드 바꿈 CDAB)","en":"40277 = lower 16 bits, 40278 = upper 16 bits (word swap, CDAB)"},"ref":"p.468 (PDF 469)","source":0},{"table":"holding-registers","address":278,"manualAddress":"40279","type":"u32","order":"CDAB","name":{"ko":"32비트 누적 전력량(0.01 kWh)","en":"32-bit cumulative energy (0.01 kWh)"},"unit":"kWh","scale":0.01,"access":"r","fc":[3],"description":{"ko":"40279 = 하위 16비트, 40280 = 상위 16비트(워드 바꿈 CDAB). 0.01 kWh 는 FR-A820-03160(55K)·FR-A840-01800(55K) 이하, 그보다 큰 용량은 0.1 kWh","en":"40279 = lower 16 bits, 40280 = upper 16 bits (word swap, CDAB). 0.01 kWh for FR-A820-03160(55K) / FR-A840-01800(55K) or lower; 0.1 kWh for larger capacities"},"ref":"p.468 (PDF 469)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh). Writing any value clears the whole fault history"},"ref":"p.726 (PDF 727)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"description":{"ko":"40508(고장 이력 8)까지 같은 형식","en":"Same format up to 40508 (fault record 8)"},"ref":"p.726 (PDF 727)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 0.5 s = 0005h"},"ref":"p.721 (PDF 722)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 1 s = 000Ah"},"ref":"p.721 (PDF 722)","source":0},{"table":"holding-registers","address":4000,"manualAddress":"44001","type":"string","name":{"ko":"형명","en":"Model name"},"access":"r","fc":[3],"len":20,"description":{"ko":"ASCII 20자(44001~44010), 빈칸은 20h. 예 FR-A840-1 → 46h 52h 2Dh …","en":"ASCII, 20 characters (44001-44010), blanks are 20h. Example FR-A840-1 → 46h 52h 2Dh ..."},"ref":"p.726 (PDF 727)","source":0},{"table":"holding-registers","address":4010,"manualAddress":"44011","type":"string","name":{"ko":"용량","en":"Capacity"},"access":"r","fc":[3],"len":6,"description":{"ko":"ASCII 6자(44011~44013), 0.1 kW 단위(0.01 kW 이하 버림), 빈칸은 20h. 예 0.75K → \"     7\"","en":"ASCII, 6 characters (44011-44013), in 0.1 kW (0.01 kW truncated), blanks are 20h. Example 0.75K → \"     7\""},"ref":"p.726 (PDF 727)","source":0}],"notes":[{"ko":"모니터 레지스터(40201~)는 모니터 항목표의 «MODBUS RTU» 칸에서 옮겼다. 그 표의 음수 표시(○)는 Modbus RTU 통신에서는 쓸 수 없어 모두 부호 없는 16비트로 적었다.","en":"Monitor registers (40201-) are taken from the 'MODBUS RTU' column of the monitor item list. Negative indication (○) in that table is not available over Modbus RTU, so all are listed as unsigned 16-bit."},{"ko":"전류·전력 배율은 FR-A820-03160(55K)·FR-A840-01800(55K) 이하 기준(scale 0.01). 그보다 큰 용량은 0.1 단위다.","en":"Current and power scales are for FR-A820-03160 (55K) / FR-A840-01800 (55K) or lower (scale 0.01); larger capacities use 0.1 increments."},{"ko":"누적 전력량 40225 는 뺐다 — 모니터 항목표의 Modbus 칸은 0.01 kWh 인데, 같은 매뉴얼의 누적 전력 절(p.471 (PDF 472))은 통신으로 읽을 때 1 kWh 단위(Pr.170 에 따라 0~9999 또는 0~65535 kWh)로 적어 서로 다르다. 단위가 표에 분명한 32비트 누적 전력량(40277~40280)을 대신 넣었다.","en":"Cumulative energy 40225 is left out: the Modbus column of the monitor list says 0.01 kWh, but the cumulative power section of the same manual (p.471 (PDF 472)) gives 1 kWh increments via communication (0-9999 or 0-65535 kWh by Pr.170). The 32-bit cumulative energy registers (40277-40280), whose units are explicit, are included instead."}],"sources":[{"title":"FR-A800 INSTRUCTION MANUAL (DETAILED)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600503ENG-P","en":"IB(NA)-0600503ENG-P"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600503eng/ib0600503engp.pdf","pages":{"ko":"Modbus RTU p.715 (PDF 716)~p.726 (PDF 727), 모니터 항목표 p.462-469 (PDF 463-470), Pr.7·Pr.21 p.374 (PDF 375), 누적 전력 p.471 (PDF 472)","en":"Modbus RTU p.715 (PDF 716) to p.726 (PDF 727), monitor item list pp.462-469 (PDF 463-470), Pr.7/Pr.21 p.374 (PDF 375), cumulative power p.471 (PDF 472)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-cs80","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-CS80","models":["FR-CS84-012~295","FR-CS82S-025~100"],"kind":"inverter","title":{"ko":"미쓰비시전기 FR-CS80 인버터 (PU 커넥터 Modbus RTU)","en":"Mitsubishi Electric FR-CS80 inverter (PU connector Modbus RTU)"},"summary":{"ko":"PU 커넥터(RS-485) Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~40508, 파라미터 41000+번호","en":"PU connector (RS-485) Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-40508, parameters 41000 + number"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,31],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.192 (PDF 193))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고(응답 … 17 70 0B B8 03 E8 2C E6 = 60·30·10 Hz), 쓰기 예(p.192 (PDF 193))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.194 (PDF 195))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.192 (PDF 193)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6) (reply ... 17 70 0B B8 03 E8 2C E6 = 60/30/10 Hz); the write example (p.192 (PDF 193)) 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.194 (PDF 195)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). Pr.117 국번 초기값 0(설정 0~31) — 0 은 브로드캐스트라 응답이 없으니 1~31 로. Pr.118 초기값 192 = 19200 bps, Pr.120 초기값 2 = 짝수 패리티·정지 1비트, 데이터 8비트 고정 (p.188 (PDF 189)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). Pr.117 station default 0 (range 0-31); 0 is broadcast (no reply), so set 1-31. Pr.118 default 192 = 19200 bps, Pr.120 default 2 = even parity, 1 stop bit, 8 data bits fixed (p.188 (PDF 189))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기·쓰기. 매뉴얼의 속도 표에는 300~1152 설정(300~115200 bps)이 있으나 Pr.118 범위는 48~1152 다.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read/write. The spec table lists 300-115200 bps but Pr.118 accepts 48-1152."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.196 (PDF 197)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하 경보)","en":"Write: RM (middle speed) / Read: OL (overload warning)"},{"bit":5,"ko":"쓰기: RL(저속)","en":"Write: RL (low speed)"},{"bit":6,"ko":"읽기: FU(출력 주파수 검출)","en":"Read: FU (output frequency detection)"},{"bit":7,"ko":"쓰기: RT(제2 기능) / 읽기: ABC(고장)","en":"Write: RT (second function) / Read: ABC (fault)"},{"bit":8,"ko":"쓰기: AU(단자 4 입력 선택)","en":"Write: AU (terminal 4 input selection)"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~182, 출력은 Pr.195 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in parentheses are initial assignments; inputs follow Pr.180-182, output Pr.195"},"ref":"p.196 (PDF 197)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU(Pr.79·Pr.340 에 따라), 0014h = NET","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU (depending on Pr.79/Pr.340), 0014h = NET"},"ref":"p.196 (PDF 197)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"설정 주파수(RAM)","en":"Set frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37 로 기계 속도 표시로 바꿀 수 있다(p.129). 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Can be changed to machine speed with Pr.37 (p.129). Manual FC06 example: 60 Hz = 1770h"},"ref":"p.196 (PDF 197)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"설정 주파수(EEPROM)","en":"Set frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.196 (PDF 197)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.37 = 0(초기값)에서 0.01 Hz, 1~9998 이면 기계 속도(1 단위)(p.129 (PDF 130))","en":"0.01 Hz with Pr.37 = 0 (initial); machine speed (increment 1) with 1-9998 (p.129 (PDF 130))"},"ref":"p.130 (PDF 131)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.130 (PDF 131)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.130 (PDF 131)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.37 = 0(초기값)에서 0.01 Hz, 1~9998 이면 기계 속도(1 단위)(p.129 (PDF 130))","en":"0.01 Hz with Pr.37 = 0 (initial); machine speed (increment 1) with 1-9998 (p.129 (PDF 130))"},"ref":"p.130 (PDF 131)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.130 (PDF 131)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal O/L relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.130 (PDF 131)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"}],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":4,"ko":"ABC","en":"ABC"}],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시","en":"Accumulates 0-65535 h, then restarts from 0"},"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":251,"manualAddress":"40252","type":"u16","name":{"ko":"PID 목표값","en":"PID set point"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":252,"manualAddress":"40253","type":"u16","name":{"ko":"PID 측정값","en":"PID measured value"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":253,"manualAddress":"40254","type":"u16","name":{"ko":"PID 편차","en":"PID deviation"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.131 (PDF 132)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh, 코드 뜻은 p.216). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh, meanings on p.216). Writing any value clears the whole fault history"},"ref":"p.197 (PDF 198)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"description":{"ko":"40508(고장 이력 8)까지 같은 형식","en":"Same format up to 40508 (fault record 8)"},"ref":"p.197 (PDF 198)","source":0},{"table":"holding-registers","address":1003,"manualAddress":"41004","type":"u16","name":{"ko":"다단 속도 고속(Pr.4)","en":"Multi-speed setting, high speed (Pr.4)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 1770h = 60.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 1770h = 60.00 Hz"},"ref":"p.192 (PDF 193)","source":0},{"table":"holding-registers","address":1004,"manualAddress":"41005","type":"u16","name":{"ko":"다단 속도 중속(Pr.5)","en":"Multi-speed setting, middle speed (Pr.5)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 0BB8h = 30.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 0BB8h = 30.00 Hz"},"ref":"p.192 (PDF 193)","source":0},{"table":"holding-registers","address":1005,"manualAddress":"41006","type":"u16","name":{"ko":"다단 속도 저속(Pr.6)","en":"Multi-speed setting, low speed (Pr.6)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 03E8h = 10.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 03E8h = 10.00 Hz"},"ref":"p.192 (PDF 193)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위(p.94 (PDF 95)). 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s increments (p.94 (PDF 95)). Manual FC10 example: 0.5 s = 0005h"},"ref":"p.194 (PDF 195)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s increments. Manual FC10 example: 1 s = 000Ah"},"ref":"p.194 (PDF 195)","source":0}],"notes":[{"ko":"누적 전력량 40225 는 넣지 않았다 — 모니터 항목표는 0.01 kWh 로, Pr.170 설명(p.130)은 통신에서 0~9999/0~65535 kWh 범위로 적어 단위가 분명하지 않다.","en":"Cumulative energy 40225 is left out: the monitor list says 0.01 kWh but the Pr.170 description (p.130) gives a 0-9999/0-65535 kWh range via communication, so the unit is unclear."},{"ko":"단자 비트는 초기 할당 기준.","en":"Terminal bits are for the initial assignments."}],"sources":[{"title":"FREQROL-CS80 INSTRUCTION MANUAL (DETAILED)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600721ENG-D","en":"IB(NA)-0600721ENG-D"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600721eng/ib0600721engd.pdf","pages":{"ko":"MODBUS RTU p.188 (PDF 189)~p.197 (PDF 198), 모니터 항목표 p.130-131 (PDF 131-132), Pr.37 p.129 (PDF 130), Pr.7 p.94 (PDF 95)","en":"MODBUS RTU p.188 (PDF 189) to p.197 (PDF 198), monitor item list pp.130-131 (PDF 131-132), Pr.37 p.129 (PDF 130), Pr.7 p.94 (PDF 95)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-d700","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-D700","models":["FR-D720","FR-D740","FR-D720S","FR-D710W"],"kind":"inverter","title":{"ko":"미쓰비시전기 FR-D700 인버터 (PU 커넥터 Modbus RTU)","en":"Mitsubishi Electric FR-D700 inverter (PU connector Modbus RTU)"},"summary":{"ko":"PU 커넥터(RS-485) Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~, 파라미터 41000+번호","en":"PU connector (RS-485) Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-, parameters 41000 + number"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.205 (PDF 209))는 국번 11h, FC03, 시작 03 EB(=1003), 3개, CRC 77 2B 로 41004~41006(Pr.4~6)을 읽고, 쓰기 예(p.206 (PDF 210))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.205 (PDF 209)) sends slave 11h, FC03, start 03 EB (=1003), 3 registers, CRC 77 2B to read 41004-41006 (Pr.4-6); the write example (p.206 (PDF 210)) sends 05 06 00 0D 17 70 17 99 to write 60 Hz to 40014. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). Pr.117 국번 초기값 0 은 «응답 없음»이라 1~247 로 바꾼다(범위 0~247(미쓰비시 프로토콜은 0~31)). Pr.118 초기값 192 = 19200 bps(48·96·192·384), Pr.120 초기값 2 = 짝수 패리티·정지 1비트(0 = 패리티 없음·정지 2비트, 1 = 홀수·1비트), 데이터 8비트 고정 (p.201 (PDF 205), p.202 (PDF 206)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). Pr.117 station default 0 means 'no reply', so set 1-247. Pr.118 default 192 = 19200 bps (48/96/192/384), Pr.120 default 2 = even parity, 1 stop bit (0 = no parity, 2 stop bits; 1 = odd, 1 stop bit), 8 data bits fixed (p.201 (PDF 205), p.202 (PDF 206))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기. PU 운전 모드에서는 Modbus RTU 를 쓸 수 없다 — NET 모드로.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read. Modbus RTU cannot be used in PU operation mode; use NET mode."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 응답 없음","en":"Write any value. No response"},"ref":"p.210 (PDF 214)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input instruction"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하)","en":"Write: RM (middle speed) / Read: OL (overload)"},{"bit":5,"ko":"쓰기: RL(저속)","en":"Write: RL (low speed)"},{"bit":6,"ko":"읽기: FU(주파수 검출)","en":"Read: FU (frequency detection)"},{"bit":7,"ko":"쓰기: 제2 기능 선택 / 읽기: ABC(고장)","en":"Write: second function selection / Read: ABC (fault)"},{"bit":8,"ko":"쓰기: 단자 4 입력 선택","en":"Write: terminal 4 input selection"},{"bit":9,"ko":"읽기: SO(안전 모니터 출력)","en":"Read: SO (safety monitor output)"},{"bit":10,"ko":"쓰기: 출력 정지","en":"Write: output stop"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당(Pr.180~ 단자 기능에 따라 바뀜). 조립 시기에 따라 사양이 다르다(매뉴얼 Ver.UP 표시).","en":"Write = control input, read = inverter status. Signals in brackets are initial assignments (change with Pr.180- terminal functions). Availability depends on date assembled (Ver.UP mark in the manual)."},"ref":"p.210 (PDF 214)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU, 0014h = NET (Pr.79·Pr.340 에 따라)","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU, 0014h = NET (depends on Pr.79/Pr.340)"},"ref":"p.210 (PDF 214)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"운전 주파수(RAM)","en":"Running frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37 설정에 따라 회전 속도(1 r/min) 단위. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Speed in 1 r/min increments depending on Pr.37. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.210 (PDF 214)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"운전 주파수(EEPROM)","en":"Running frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.210 (PDF 214)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.37 = 0.01~9998 이면 정수(1)","en":"Integer (1) when Pr.37 = 0.01-9998"},"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"주파수 설정값","en":"Frequency setting"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 듀티","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"}],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":5,"ko":"ABC","en":"ABC"},{"bit":7,"ko":"SO","en":"SO"}],"ref":"p.211 (PDF 215)","source":0,"description":{"ko":"조립 시기에 따라 사양이 다르다(매뉴얼 Ver.UP 표시).","en":"Availability depends on date assembled (Ver.UP mark in the manual)."}},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실제 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":224,"manualAddress":"40225","type":"u16","name":{"ko":"누적 전력량","en":"Cumulative power"},"unit":"kWh","access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":262,"manualAddress":"40263","type":"u16","name":{"ko":"누적 전력량 2","en":"Cumulative power 2"},"unit":"kWh","scale":0.01,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":263,"manualAddress":"40264","type":"u16","name":{"ko":"PTC 서미스터 저항","en":"PTC thermistor resistance"},"unit":"kΩ","scale":0.01,"access":"r","fc":[3],"ref":"p.211 (PDF 215)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"고장 없음","en":"No fault"},{"value":16,"ko":"E.OC1","en":"E.OC1"},{"value":17,"ko":"E.OC2","en":"E.OC2"},{"value":18,"ko":"E.OC3","en":"E.OC3"},{"value":32,"ko":"E.OV1","en":"E.OV1"},{"value":33,"ko":"E.OV2","en":"E.OV2"},{"value":34,"ko":"E.OV3","en":"E.OV3"},{"value":48,"ko":"E.THT","en":"E.THT"},{"value":49,"ko":"E.THM","en":"E.THM"},{"value":64,"ko":"E.FIN","en":"E.FIN"},{"value":82,"ko":"E.ILF","en":"E.ILF"},{"value":96,"ko":"E.OLT","en":"E.OLT"},{"value":112,"ko":"E.BE","en":"E.BE"},{"value":128,"ko":"E.GF","en":"E.GF"},{"value":129,"ko":"E.LF","en":"E.LF"},{"value":144,"ko":"E.OHT","en":"E.OHT"},{"value":145,"ko":"E.PTC","en":"E.PTC"},{"value":176,"ko":"E.PE","en":"E.PE"},{"value":177,"ko":"E.PUE","en":"E.PUE"},{"value":178,"ko":"E.RET","en":"E.RET"},{"value":192,"ko":"E.CPU","en":"E.CPU"},{"value":196,"ko":"E.CDO","en":"E.CDO"},{"value":197,"ko":"E.IOH","en":"E.IOH"},{"value":199,"ko":"E.AIE","en":"E.AIE"},{"value":201,"ko":"E.SAF","en":"E.SAF"},{"value":245,"ko":"E.5","en":"E.5"}],"description":{"ko":"하위 바이트가 고장 코드(00xxh). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh). Writing any value clears the whole fault history"},"ref":"p.212 (PDF 216)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"values":[{"value":0,"ko":"고장 없음","en":"No fault"},{"value":16,"ko":"E.OC1","en":"E.OC1"},{"value":17,"ko":"E.OC2","en":"E.OC2"},{"value":18,"ko":"E.OC3","en":"E.OC3"},{"value":32,"ko":"E.OV1","en":"E.OV1"},{"value":33,"ko":"E.OV2","en":"E.OV2"},{"value":34,"ko":"E.OV3","en":"E.OV3"},{"value":48,"ko":"E.THT","en":"E.THT"},{"value":49,"ko":"E.THM","en":"E.THM"},{"value":64,"ko":"E.FIN","en":"E.FIN"},{"value":82,"ko":"E.ILF","en":"E.ILF"},{"value":96,"ko":"E.OLT","en":"E.OLT"},{"value":112,"ko":"E.BE","en":"E.BE"},{"value":128,"ko":"E.GF","en":"E.GF"},{"value":129,"ko":"E.LF","en":"E.LF"},{"value":144,"ko":"E.OHT","en":"E.OHT"},{"value":145,"ko":"E.PTC","en":"E.PTC"},{"value":176,"ko":"E.PE","en":"E.PE"},{"value":177,"ko":"E.PUE","en":"E.PUE"},{"value":178,"ko":"E.RET","en":"E.RET"},{"value":192,"ko":"E.CPU","en":"E.CPU"},{"value":196,"ko":"E.CDO","en":"E.CDO"},{"value":197,"ko":"E.IOH","en":"E.IOH"},{"value":199,"ko":"E.AIE","en":"E.AIE"},{"value":201,"ko":"E.SAF","en":"E.SAF"},{"value":245,"ko":"E.5","en":"E.5"}],"description":{"ko":"하위 바이트가 고장 코드","en":"Low byte is the fault code"},"ref":"p.212 (PDF 216)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. Manual FC10 example: 0.5 s = 0005h"},"ref":"p.208 (PDF 212)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 FC10 예: 1 s = 000Ah","en":"Manual FC10 example: 1 s = 000Ah"},"ref":"p.208 (PDF 212)","source":0}],"sources":[{"title":"FR-D700 INSTRUCTION MANUAL (Applied)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600366ENG-H, 2018년 6월","en":"IB(NA)-0600366ENG-H, June 2018"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600366eng/ib0600366engh.pdf","pages":{"ko":"Modbus RTU p.201 (PDF 205)~p.212 (PDF 216), 파라미터 목록 Pr.7·8 단위 0.1 s p.60 (PDF 71)","en":"Modbus RTU p.201 (PDF 205) to p.212 (PDF 216), parameter list Pr.7/8 increments 0.1 s p.60 (PDF 71)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-d800","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-D800","models":["FR-D820","FR-D840","FR-D820S","FR-D810W"],"kind":"inverter","title":{"ko":"미쓰비시전기 FR-D800 인버터 (RS-485 Modbus RTU, 표준 모델)","en":"Mitsubishi Electric FR-D800 inverter (RS-485 Modbus RTU, standard model)"},"summary":{"ko":"PU 커넥터·RS-485 단자 Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 모니터 40201~(Pr.52 모니터 코드 2), 고장 이력 40501~40510, 파라미터 41000+번호, 형명 44001~","en":"PU connector / RS-485 terminals Modbus RTU. Holding registers in 40001 form: system variables 40002-, monitors 40201- (Pr.52 monitor code 2), fault history 40501-40510, parameters 41000 + number, model name 44001-"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.35 (PDF 36))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고(응답 … 17 70 0B B8 03 E8 2C E6 = 60·30·10 Hz), 쓰기 예(p.35 (PDF 36))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.37 (PDF 38))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.35 (PDF 36)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6) (reply ... 17 70 0B B8 03 E8 2C E6 = 60/30/10 Hz); the write example (p.35 (PDF 36)) 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.37 (PDF 38)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). Pr.117 국번 초기값 0 은 브로드캐스트라 응답이 없으니 1~247 로. Pr.118 초기값 192 = 19200 bps, Pr.120 초기값 2 = 짝수 패리티·정지 1비트(Pr.119 정지 비트는 Pr.120 = 0 일 때만), 데이터 8비트 고정. 설정을 바꾼 뒤 인버터를 리셋해야 적용된다 (통신 매뉴얼 p.31-32 (PDF 32-33)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). Pr.117 station default 0 is broadcast (no reply), so set 1-247. Pr.118 default 192 = 19200 bps, Pr.120 default 2 = even parity, 1 stop bit (Pr.119 stop bits apply only when Pr.120 = 0), 8 data bits fixed. Reset the inverter after changing these (Communication manual pp.31-32 (PDF 32-33))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지. Pr.549 = 1 이고 Pr.118 = 384(38400 bps)이면 파라미터 유닛을 쓸 수 없다.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers. With Pr.549 = 1 and Pr.118 = 384 (38400 bps) the parameter unit cannot be used."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.39 (PDF 40)","source":0},{"table":"holding-registers","address":7,"manualAddress":"40008","type":"u16","name":{"ko":"인버터 상태(확장) / 제어 입력 명령(확장)","en":"Inverter status (extended) / control input command (extended)"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: NET X1 / 읽기: NET Y1","en":"Write: NET X1 / Read: NET Y1"},{"bit":1,"ko":"쓰기: NET X2 / 읽기: NET Y2","en":"Write: NET X2 / Read: NET Y2"},{"bit":2,"ko":"쓰기: NET X3 / 읽기: NET Y3","en":"Write: NET X3 / Read: NET Y3"},{"bit":3,"ko":"쓰기: NET X4 / 읽기: NET Y4","en":"Write: NET X4 / Read: NET Y4"},{"bit":4,"ko":"쓰기: NET X5","en":"Write: NET X5"}],"description":{"ko":"NET X·Y 는 초기에는 할당 없음 — Pr.180~ 와 Pr.190~ 으로 기능을 준다","en":"NET X/Y have no function initially; assign with Pr.180- and Pr.190-"},"ref":"p.39-40 (PDF 40-41)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: 주파수 도달","en":"Write: RH (high speed) / Read: up to frequency"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: 과부하 경보","en":"Write: RM (middle speed) / Read: overload warning"},{"bit":5,"ko":"쓰기: RL(저속)","en":"Write: RL (low speed)"},{"bit":6,"ko":"쓰기: JOG 운전 선택 2 / 읽기: FU(출력 주파수 검출)","en":"Write: JOG operation selection 2 / Read: FU (output frequency detection)"},{"bit":7,"ko":"쓰기: 제2 기능 선택 / 읽기: ABC(고장)","en":"Write: second function selection / Read: ABC (fault)"},{"bit":8,"ko":"쓰기: 단자 4 입력 선택","en":"Write: terminal 4 input selection"},{"bit":9,"ko":"읽기: 안전 모니터 출력 2","en":"Read: safety monitor output 2"},{"bit":10,"ko":"쓰기: 출력 정지","en":"Write: output stop"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~182·Pr.185~189, 출력은 Pr.190~196 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in parentheses are initial assignments; inputs follow Pr.180-182/Pr.185-189, outputs Pr.190-196"},"ref":"p.39-40 (PDF 40-41)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU(Pr.79·Pr.340 에 따라), 0014h = NET","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU (depending on Pr.79/Pr.340), 0014h = NET"},"ref":"p.39-40 (PDF 40-41)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"설정 주파수(RAM)","en":"Set frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37·Pr.53 으로 회전 속도(기계 속도) 표시로 바꿀 수 있다. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Can be changed to rotation (machine) speed with Pr.37/Pr.53. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.39 (PDF 40)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"설정 주파수(EEPROM)","en":"Set frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.39 (PDF 40)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.53 설정에 따라 단위가 바뀐다(기능 매뉴얼 p.206 (PDF 207))","en":"Unit changes with Pr.53 (Function manual p.206 (PDF 207))"},"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.53 설정에 따라 단위가 바뀐다(기능 매뉴얼 p.206 (PDF 207))","en":"Unit changes with Pr.53 (Function manual p.206 (PDF 207))"},"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":205,"manualAddress":"40206","type":"u16","name":{"ko":"운전 속도","en":"Operation speed"},"unit":"r/min","access":"r","fc":[3],"description":{"ko":"Pr.53 설정에 따라 단위가 바뀐다(기능 매뉴얼 p.206 (PDF 207))","en":"Unit changes with Pr.53 (Function manual p.206 (PDF 207))"},"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":206,"manualAddress":"40207","type":"u16","name":{"ko":"모터 토크","en":"Motor torque"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 사용률","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal O/L relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크값","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":211,"manualAddress":"40212","type":"u16","name":{"ko":"컨버터 출력 전압 피크값","en":"Converter output voltage peak value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":212,"manualAddress":"40213","type":"u16","name":{"ko":"입력 전력","en":"Input power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"}],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"p.210-211 (PDF 211-212)","source":1},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC","en":"ABC"},{"bit":7,"ko":"So(SO)","en":"So(SO)"}],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"p.210-211 (PDF 211-212)","source":1},{"table":"holding-registers","address":216,"manualAddress":"40217","type":"u16","name":{"ko":"로드 미터","en":"Load meter"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":217,"manualAddress":"40218","type":"u16","name":{"ko":"모터 여자 전류","en":"Motor excitation current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.563)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.563)"},"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.564)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.564)"},"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":236,"manualAddress":"40237","type":"u16","name":{"ko":"방열판 온도","en":"Heat sink temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.209 (PDF 210)","source":1},{"table":"holding-registers","address":251,"manualAddress":"40252","type":"u16","name":{"ko":"PID 목표값","en":"PID set point"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.210 (PDF 211)","source":1},{"table":"holding-registers","address":252,"manualAddress":"40253","type":"u16","name":{"ko":"PID 측정값","en":"PID measured value"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.210 (PDF 211)","source":1},{"table":"holding-registers","address":253,"manualAddress":"40254","type":"u16","name":{"ko":"PID 편차","en":"PID deviation"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.210 (PDF 211)","source":1},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.210 (PDF 211)","source":1},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.210 (PDF 211)","source":1},{"table":"holding-registers","address":276,"manualAddress":"40277","type":"u32","name":{"ko":"32비트 누적 전력량(kWh)","en":"32-bit cumulative energy (kWh)"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"40277 = 하위 16비트, 40278 = 상위 16비트(워드 바꿈 CDAB)","en":"40277 = lower 16 bits, 40278 = upper 16 bits (word swap, CDAB)"},"ref":"p.210 (PDF 211)","source":1,"order":"CDAB"},{"table":"holding-registers","address":278,"manualAddress":"40279","type":"u32","name":{"ko":"32비트 누적 전력량(0.01 kWh)","en":"32-bit cumulative energy (0.01 kWh)"},"unit":"kWh","scale":0.01,"access":"r","fc":[3],"description":{"ko":"40279 = 하위 16비트, 40280 = 상위 16비트(워드 바꿈 CDAB)","en":"40279 = lower 16 bits, 40280 = upper 16 bits (word swap, CDAB)"},"ref":"p.210 (PDF 211)","source":1,"order":"CDAB"},{"table":"holding-registers","address":297,"manualAddress":"40298","type":"u16","name":{"ko":"제어 회로 온도","en":"Control circuit temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.210 (PDF 211)","source":1},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh, 코드 뜻은 유지보수 매뉴얼). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh, meanings in the Maintenance manual). Writing any value clears the whole fault history"},"ref":"p.41 (PDF 42)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"description":{"ko":"40510(고장 이력 10)까지 같은 형식","en":"Same format up to 40510 (fault record 10)"},"ref":"p.41 (PDF 42)","source":0},{"table":"holding-registers","address":1003,"manualAddress":"41004","type":"u16","name":{"ko":"다단 속도 고속(Pr.4)","en":"Multi-speed setting, high speed (Pr.4)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 1770h = 60.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 1770h = 60.00 Hz"},"ref":"p.35 (PDF 36)","source":0},{"table":"holding-registers","address":1004,"manualAddress":"41005","type":"u16","name":{"ko":"다단 속도 중속(Pr.5)","en":"Multi-speed setting, middle speed (Pr.5)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 0BB8h = 30.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 0BB8h = 30.00 Hz"},"ref":"p.35 (PDF 36)","source":0},{"table":"holding-registers","address":1005,"manualAddress":"41006","type":"u16","name":{"ko":"다단 속도 저속(Pr.6)","en":"Multi-speed setting, low speed (Pr.6)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 03E8h = 10.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 03E8h = 10.00 Hz"},"ref":"p.35 (PDF 36)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위(기능 매뉴얼 p.47 (PDF 48)). 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s increments (Function manual p.47 (PDF 48)). Manual FC10 example: 0.5 s = 0005h"},"ref":"p.37 (PDF 38)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s increments. Manual FC10 example: 1 s = 000Ah"},"ref":"p.37 (PDF 38)","source":0},{"table":"holding-registers","address":4000,"manualAddress":"44001","type":"string","name":{"ko":"형명","en":"Model name"},"access":"r","fc":[3],"len":20,"description":{"ko":"ASCII 20자(44001~44010), 빈칸은 20h. 예 FR-D820 → 46h 52h 2Dh 44h …","en":"ASCII, 20 characters (44001-44010), blanks are 20h. Example FR-D820 → 46h 52h 2Dh 44h ..."},"ref":"p.42 (PDF 43)","source":0},{"table":"holding-registers","address":4010,"manualAddress":"44011","type":"string","name":{"ko":"용량","en":"Capacity"},"access":"r","fc":[3],"len":6,"description":{"ko":"ASCII 6자(44011~44013), 0.1 kW 단위(0.01 kW 이하 버림), 빈칸은 20h. 예 0.75K → \"     7\"","en":"ASCII, 6 characters (44011-44013), in 0.1 kW (0.01 kW truncated), blanks are 20h. Example 0.75K → \"     7\""},"ref":"p.42 (PDF 43)","source":0}],"notes":[{"ko":"모니터 레지스터(40201~)는 기능 매뉴얼 모니터 항목표의 «Monitor code 2»(MODBUS RTU) 칸에서 옮겼다. 표준 모델(이더넷 모델 아님) 매뉴얼 기준.","en":"Monitor registers (40201-) are from the 'Monitor code 2' (MODBUS RTU) column of the monitor item list in the Function manual. Based on the standard-model (non-Ethernet) manuals."},{"ko":"누적 전력량 40225 는 넣지 않았다 — 항목표는 0.01 kWh 로, 같은 매뉴얼의 누적 전력 절(p.213)은 통신에서 1 kWh 단위로 적어 서로 다르다. 단위가 분명한 32비트 누적 전력량(40277~40280)을 대신 넣었다.","en":"Cumulative energy 40225 is left out: the item list says 0.01 kWh but the cumulative power section (p.213) gives 1 kWh via communication. The 32-bit cumulative energy registers (40277-40280), whose units are explicit, are included instead."}],"sources":[{"title":"FR-D800 Instruction Manual (Communication) (Standard model)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0601039ENG-A","en":"IB(NA)-0601039ENG-A"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0601039eng/ib0601039enga.pdf","pages":{"ko":"2.6 MODBUS RTU p.31 (PDF 32)~p.42 (PDF 43)","en":"2.6 MODBUS RTU p.31 (PDF 32) to p.42 (PDF 43)"},"checked":"2026-10-23"},{"title":"FR-D800 Instruction Manual (Function) (Standard model)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0601034ENG-C","en":"IB(NA)-0601034ENG-C"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0601034eng/ib0601034engc.pdf","pages":{"ko":"모니터 항목표 p.209-211 (PDF 210-212), 누적 전력 p.213 (PDF 214), Pr.53 p.206 (PDF 207), 파라미터 목록 Pr.4~8 p.47 (PDF 48)","en":"Monitor item list pp.209-211 (PDF 210-212), cumulative power p.213 (PDF 214), Pr.53 p.206 (PDF 207), parameter list Pr.4-8 p.47 (PDF 48)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-e700","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-E700","models":["FR-E720","FR-E740","FR-E720S","FR-E710W"],"kind":"inverter","title":{"ko":"미쓰비시전기 FR-E700 인버터 (PU 커넥터 Modbus RTU)","en":"Mitsubishi Electric FR-E700 inverter (PU connector Modbus RTU)"},"summary":{"ko":"PU 커넥터(RS-485) Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~, 파라미터 41000+번호","en":"PU connector (RS-485) Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-, parameters 41000 + number"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.238 (PDF 240))는 국번 11h, FC03, 시작 03 EB(=1003), 3개, CRC 77 2B 로 41004~41006(Pr.4~6)을 읽고, 쓰기 예(p.239 (PDF 241))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.238 (PDF 240)) sends slave 11h, FC03, start 03 EB (=1003), 3 registers, CRC 77 2B to read 41004-41006 (Pr.4-6); the write example (p.239 (PDF 241)) sends 05 06 00 0D 17 70 17 99 to write 60 Hz to 40014. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). Pr.117 국번 초기값 0 은 «응답 없음»이라 1~247 로 바꾼다(범위 0~247). Pr.118 초기값 192 = 19200 bps(48·96·192·384), Pr.120 초기값 2 = 짝수 패리티·정지 1비트(0 = 패리티 없음·정지 2비트, 1 = 홀수·1비트), 데이터 8비트 고정 (p.234 (PDF 236), p.235 (PDF 237)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). Pr.117 station default 0 means 'no reply', so set 1-247. Pr.118 default 192 = 19200 bps (48/96/192/384), Pr.120 default 2 = even parity, 1 stop bit (0 = no parity, 2 stop bits; 1 = odd, 1 stop bit), 8 data bits fixed (p.234 (PDF 236), p.235 (PDF 237))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기. PU 운전 모드에서는 Modbus RTU 를 쓸 수 없다 — NET 모드로.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read. Modbus RTU cannot be used in PU operation mode; use NET mode."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 응답 없음","en":"Write any value. No response"},"ref":"p.243 (PDF 245)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input instruction"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하)","en":"Write: RM (middle speed) / Read: OL (overload)"},{"bit":5,"ko":"쓰기: RL(저속)","en":"Write: RL (low speed)"},{"bit":6,"ko":"읽기: FU(주파수 검출)","en":"Read: FU (frequency detection)"},{"bit":7,"ko":"쓰기: RT(제2 기능) / 읽기: ABC(고장)","en":"Write: RT (second function) / Read: ABC (fault)"},{"bit":8,"ko":"쓰기: AU(전류 입력 선택)","en":"Write: AU (current input selection)"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":12,"ko":"쓰기: RES(리셋)","en":"Write: RES (reset)"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당(Pr.180~ 단자 기능에 따라 바뀜)","en":"Write = control input, read = inverter status. Signals in brackets are initial assignments (change with Pr.180- terminal functions)"},"ref":"p.243 (PDF 245)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU, 0014h = NET (Pr.79·Pr.340 에 따라)","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU, 0014h = NET (depends on Pr.79/Pr.340)"},"ref":"p.243 (PDF 245)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"운전 주파수(RAM)","en":"Running frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37 설정에 따라 회전 속도(1 r/min) 단위. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Speed in 1 r/min increments depending on Pr.37. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.243 (PDF 245)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"운전 주파수(EEPROM)","en":"Running frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.243 (PDF 245)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.37 = 0.01~9998 이면 정수(1)","en":"Integer (1) when Pr.37 = 0.01-9998"},"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"주파수 설정값","en":"Frequency setting"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":206,"manualAddress":"40207","type":"u16","name":{"ko":"모터 토크","en":"Motor torque"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 듀티","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"},{"bit":8,"ko":"MRS","en":"MRS"},{"bit":10,"ko":"RES","en":"RES"}],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC","en":"ABC"}],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실제 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":224,"manualAddress":"40225","type":"u16","name":{"ko":"누적 전력량","en":"Cumulative power"},"unit":"kWh","access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":262,"manualAddress":"40263","type":"u16","name":{"ko":"누적 전력량 2","en":"Cumulative power 2"},"unit":"kWh","scale":0.01,"access":"r","fc":[3],"description":{"ko":"조립 시기에 따라 사양이 다르다(Ver.UP 표시)","en":"Availability depends on date assembled (Ver.UP mark)"},"ref":"p.244 (PDF 246)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"고장 없음","en":"No fault"},{"value":16,"ko":"E.OC1","en":"E.OC1"},{"value":17,"ko":"E.OC2","en":"E.OC2"},{"value":18,"ko":"E.OC3","en":"E.OC3"},{"value":32,"ko":"E.OV1","en":"E.OV1"},{"value":33,"ko":"E.OV2","en":"E.OV2"},{"value":34,"ko":"E.OV3","en":"E.OV3"},{"value":48,"ko":"E.THT","en":"E.THT"},{"value":49,"ko":"E.THM","en":"E.THM"},{"value":64,"ko":"E.FIN","en":"E.FIN"},{"value":82,"ko":"E.ILF","en":"E.ILF"},{"value":96,"ko":"E.OLT","en":"E.OLT"},{"value":112,"ko":"E.BE","en":"E.BE"},{"value":128,"ko":"E.GF","en":"E.GF"},{"value":129,"ko":"E.LF","en":"E.LF"},{"value":144,"ko":"E.OHT","en":"E.OHT"},{"value":160,"ko":"E.OPT","en":"E.OPT"},{"value":161,"ko":"E.OP1","en":"E.OP1"},{"value":176,"ko":"E.PE","en":"E.PE"},{"value":177,"ko":"E.PUE","en":"E.PUE"},{"value":178,"ko":"E.RET","en":"E.RET"},{"value":179,"ko":"E.PE2","en":"E.PE2"},{"value":192,"ko":"E.CPU","en":"E.CPU"},{"value":197,"ko":"E.IOH","en":"E.IOH"},{"value":199,"ko":"E.AIE","en":"E.AIE"},{"value":200,"ko":"E.USB","en":"E.USB"},{"value":201,"ko":"E.SAF","en":"E.SAF"},{"value":216,"ko":"E.MB4","en":"E.MB4"},{"value":217,"ko":"E.MB5","en":"E.MB5"},{"value":218,"ko":"E.MB6","en":"E.MB6"},{"value":219,"ko":"E.MB7","en":"E.MB7"},{"value":241,"ko":"E.1","en":"E.1"},{"value":245,"ko":"E.5","en":"E.5"},{"value":246,"ko":"E.6","en":"E.6"},{"value":247,"ko":"E.7","en":"E.7"},{"value":253,"ko":"E.13","en":"E.13"}],"description":{"ko":"하위 바이트가 고장 코드(00xxh). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh). Writing any value clears the whole fault history"},"ref":"p.245 (PDF 247)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"values":[{"value":0,"ko":"고장 없음","en":"No fault"},{"value":16,"ko":"E.OC1","en":"E.OC1"},{"value":17,"ko":"E.OC2","en":"E.OC2"},{"value":18,"ko":"E.OC3","en":"E.OC3"},{"value":32,"ko":"E.OV1","en":"E.OV1"},{"value":33,"ko":"E.OV2","en":"E.OV2"},{"value":34,"ko":"E.OV3","en":"E.OV3"},{"value":48,"ko":"E.THT","en":"E.THT"},{"value":49,"ko":"E.THM","en":"E.THM"},{"value":64,"ko":"E.FIN","en":"E.FIN"},{"value":82,"ko":"E.ILF","en":"E.ILF"},{"value":96,"ko":"E.OLT","en":"E.OLT"},{"value":112,"ko":"E.BE","en":"E.BE"},{"value":128,"ko":"E.GF","en":"E.GF"},{"value":129,"ko":"E.LF","en":"E.LF"},{"value":144,"ko":"E.OHT","en":"E.OHT"},{"value":160,"ko":"E.OPT","en":"E.OPT"},{"value":161,"ko":"E.OP1","en":"E.OP1"},{"value":176,"ko":"E.PE","en":"E.PE"},{"value":177,"ko":"E.PUE","en":"E.PUE"},{"value":178,"ko":"E.RET","en":"E.RET"},{"value":179,"ko":"E.PE2","en":"E.PE2"},{"value":192,"ko":"E.CPU","en":"E.CPU"},{"value":197,"ko":"E.IOH","en":"E.IOH"},{"value":199,"ko":"E.AIE","en":"E.AIE"},{"value":200,"ko":"E.USB","en":"E.USB"},{"value":201,"ko":"E.SAF","en":"E.SAF"},{"value":216,"ko":"E.MB4","en":"E.MB4"},{"value":217,"ko":"E.MB5","en":"E.MB5"},{"value":218,"ko":"E.MB6","en":"E.MB6"},{"value":219,"ko":"E.MB7","en":"E.MB7"},{"value":241,"ko":"E.1","en":"E.1"},{"value":245,"ko":"E.5","en":"E.5"},{"value":246,"ko":"E.6","en":"E.6"},{"value":247,"ko":"E.7","en":"E.7"},{"value":253,"ko":"E.13","en":"E.13"}],"description":{"ko":"하위 바이트가 고장 코드","en":"Low byte is the fault code"},"ref":"p.245 (PDF 247)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s 단위(범위 0~360 s). 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s units apply with Pr.21 = 0 (initial); with Pr.21 = 1 the unit is 0.01 s (range 0-360 s). Manual FC10 example: 0.5 s = 0005h"},"ref":"p.241 (PDF 243)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 1 s = 000Ah"},"ref":"p.241 (PDF 243)","source":0}],"sources":[{"title":"FR-E700 INSTRUCTION MANUAL (Applied)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600277ENG-G, 2018년 7월","en":"IB(NA)-0600277ENG-G, July 2018"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600277eng/ib0600277engg.pdf","pages":{"ko":"Modbus RTU p.234 (PDF 236)~p.245 (PDF 247), 가감속 시간 단위 Pr.21 p.111 (PDF 113)","en":"Modbus RTU p.234 (PDF 236) to p.245 (PDF 247), acceleration/deceleration time increments Pr.21 p.111 (PDF 113)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-e800","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-E800","kind":"inverter","title":{"ko":"미쓰비시전기 FR-E800 인버터 (PU 커넥터 Modbus RTU)","en":"Mitsubishi Electric FR-E800 inverter (PU connector Modbus RTU)"},"summary":{"ko":"PU 커넥터(RS-485) Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 모니터 40201~(Pr.52 모니터 코드 2), 고장 이력 40501~40510, 파라미터 41000+번호, 형명 44001~","en":"PU connector (RS-485) Modbus RTU. Holding registers in 40001 form: system variables 40002-, monitors 40201- (Pr.52 monitor code 2), fault history 40501-40510, parameters 41000 + number, model name 44001-"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 통신 매뉴얼 읽기 예(p.261 (PDF 262))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고, 쓰기 예는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.263 (PDF 264))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example in the communication manual (p.261 (PDF 262)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6); the write example 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.263 (PDF 264)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). Pr.117 국번 초기값 0 은 브로드캐스트라 응답이 없으니 1~247 로 바꾼다. Pr.118 초기값 192 = 19200 bps, Pr.120 초기값 2 = 짝수 패리티·정지 1비트(Pr.119 정지 비트는 Pr.120 = 0 일 때만), 데이터 8비트 고정. 설정을 바꾼 뒤에는 인버터를 리셋해야 적용된다 (p.257~258 (PDF 258~259)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). Pr.117 station default 0 is broadcast (no reply), so set 1-247. Pr.118 default 192 = 19200 bps, Pr.120 default 2 = even parity, 1 stop bit (Pr.119 stop bits apply only when Pr.120 = 0), 8 data bits fixed. Reset the inverter after changing these (pp.257-258 (PDF 258-259))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기·쓰기. 통신 옵션이 달려 있고 Pr.550 = 9999(초기값)이면 PU 커넥터의 운전 명령은 무효.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read/write. With a communication option installed and Pr.550 = 9999 (initial), operation commands from the PU connector are invalid."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.265 (PDF 266)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: 주파수 도달","en":"Write: RH (high speed) / Read: up to frequency"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: 과부하 경보","en":"Write: RM (middle speed) / Read: overload warning"},{"bit":5,"ko":"쓰기: RL(저속)","en":"Write: RL (low speed)"},{"bit":6,"ko":"쓰기: JOG 운전 선택 2 / 읽기: FU(출력 주파수 검출)","en":"Write: JOG operation selection 2 / Read: FU (output frequency detection)"},{"bit":7,"ko":"쓰기: 제2 기능 선택 / 읽기: ABC(고장)","en":"Write: second function selection / Read: ABC (fault)"},{"bit":8,"ko":"쓰기: 단자 4 입력 선택 / 읽기: ABC2(기능 없음)","en":"Write: terminal 4 input selection / Read: ABC2 (no function)"},{"bit":9,"ko":"읽기: 안전 모니터 출력 2","en":"Read: safety monitor output 2"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":11,"ko":"읽기: 위치 결정 완료","en":"Read: in-position"},{"bit":12,"ko":"쓰기: RES(리셋) / 읽기: 위치 지령 운전 중","en":"Write: RES (reset) / Read: during position command operation"},{"bit":13,"ko":"읽기: 원점 복귀 완료","en":"Read: home position return completed"},{"bit":14,"ko":"읽기: 원점 복귀 실패","en":"Read: home position return failure"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~189, 출력은 Pr.190~197 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in brackets are initial assignments; inputs change with Pr.180-189, outputs with Pr.190-197"},"ref":"p.265 (PDF 266)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU(Pr.79·Pr.340 에 따라), 0014h = NET","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU (depending on Pr.79/Pr.340), 0014h = NET"},"ref":"p.266 (PDF 267)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"설정 주파수(RAM)","en":"Set frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37·Pr.53 으로 회전 속도(기계 속도) 표시로 바꿀 수 있다. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Can be switched to speed (machine speed) display with Pr.37/Pr.53. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.265 (PDF 266)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"설정 주파수(EEPROM)","en":"Set frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.265 (PDF 266)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.53 설정에 따라 단위가 바뀐다","en":"Increment changes with Pr.53"},"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"Pr.53 설정에 따라 단위가 바뀐다","en":"Increment changes with Pr.53"},"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":205,"manualAddress":"40206","type":"u16","name":{"ko":"운전 속도","en":"Operation speed"},"unit":"r/min","access":"r","fc":[3],"description":{"ko":"Pr.53 설정에 따라 단위가 바뀐다","en":"Increment changes with Pr.53"},"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":206,"manualAddress":"40207","type":"u16","name":{"ko":"모터 토크","en":"Motor torque"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 사용률","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal O/L relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크값","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":211,"manualAddress":"40212","type":"u16","name":{"ko":"컨버터 출력 전압 피크값","en":"Converter output voltage peak value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":212,"manualAddress":"40213","type":"u16","name":{"ko":"입력 전력","en":"Input power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"ref":"p.395 (PDF 396)","source":1},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"},{"bit":8,"ko":"MRS","en":"MRS"},{"bit":10,"ko":"RES","en":"RES"}],"description":{"ko":"표준 모델 기준 비트(이더넷·IP67·안전 통신·CC-Link 모델과 FR-A8AC 장착 시는 다르다)","en":"Bits for the standard model (Ethernet, IP67, safety communication and CC-Link models, and with FR-A8AC, differ)"},"ref":"p.397, p.399 (PDF 398, 400)","source":1},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC","en":"ABC"},{"bit":7,"ko":"SO","en":"SO"}],"description":{"ko":"표준 모델 기준 비트. FR-E8TR·FR-E8TE7 장착 시 SO 는 늘 OFF","en":"Bits for the standard model. SO is always OFF with FR-E8TR or FR-E8TE7 installed"},"ref":"p.397, p.399 (PDF 398, 400)","source":1},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.563)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.563)"},"ref":"p.396 (PDF 397)","source":1},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.564)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.564)"},"ref":"p.396 (PDF 397)","source":1},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.396 (PDF 397)","source":1},{"table":"holding-registers","address":236,"manualAddress":"40237","type":"u16","name":{"ko":"방열판 온도","en":"Heat sink temperature"},"unit":"℃","access":"r","fc":[3],"description":{"ko":"FR-E820-0175(3.7K)·FR-E840-0060(2.2K)·FR-E846-0060(2.2K) 이상만, 그 밖에는 늘 0","en":"Only FR-E820-0175 (3.7K), FR-E840-0060 (2.2K), FR-E846-0060 (2.2K) and larger; otherwise always 0"},"ref":"p.396 (PDF 397)","source":1},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.397 (PDF 398)","source":1},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.397 (PDF 398)","source":1},{"table":"holding-registers","address":276,"manualAddress":"40277","type":"u32","order":"CDAB","name":{"ko":"32비트 누적 전력량(kWh)","en":"32-bit cumulative energy (kWh)"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"40277 = 하위 16비트, 40278 = 상위 16비트(워드 바꿈 CDAB)","en":"40277 = lower 16 bits, 40278 = upper 16 bits (word swap, CDAB)"},"ref":"p.398 (PDF 399)","source":1},{"table":"holding-registers","address":278,"manualAddress":"40279","type":"u32","order":"CDAB","name":{"ko":"32비트 누적 전력량(0.01 kWh)","en":"32-bit cumulative energy (0.01 kWh)"},"unit":"kWh","scale":0.01,"access":"r","fc":[3],"description":{"ko":"40279 = 하위 16비트, 40280 = 상위 16비트(워드 바꿈 CDAB)","en":"40279 = lower 16 bits, 40280 = upper 16 bits (word swap, CDAB)"},"ref":"p.398 (PDF 399)","source":1},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh, 코드 뜻은 유지보수 매뉴얼). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh; meanings in the Maintenance manual). Writing any value clears the whole fault history"},"ref":"p.267 (PDF 268)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"description":{"ko":"40510(고장 이력 10)까지 같은 형식","en":"Same format up to 40510 (fault record 10)"},"ref":"p.267 (PDF 268)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 0.5 s = 0005h"},"ref":"p.263 (PDF 264)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 1 s = 000Ah"},"ref":"p.263 (PDF 264)","source":0},{"table":"holding-registers","address":4000,"manualAddress":"44001","type":"string","name":{"ko":"형명","en":"Model name"},"access":"r","fc":[3],"len":20,"description":{"ko":"ASCII 20자(44001~44010), 빈칸은 20h. 예 FR-E820-1 → 46h 52h 2Dh 45h …","en":"ASCII, 20 characters (44001-44010), blanks are 20h. Example FR-E820-1 → 46h 52h 2Dh 45h ..."},"ref":"p.267 (PDF 268)","source":0}],"notes":[{"ko":"모니터 레지스터(40201~)는 기능 매뉴얼 Pr.52 모니터 항목표의 «모니터 코드 2» 칸에서 옮겼다. 그 표의 음수 표시(○)는 RS-485(Modbus RTU) 통신에서는 쓸 수 없어 모두 부호 없는 16비트로 적었다.","en":"Monitor registers (40201-) are taken from the 'monitor code 2' column of the Pr.52 monitor item list in the Function manual. Negative indication (○) in that table is not available over RS-485 (Modbus RTU), so all are listed as unsigned 16-bit."},{"ko":"비트 뜻은 표준 모델 기준. 제조 시기에 따라 사양이 다를 수 있다(기능 매뉴얼 p.399 NOTE).","en":"Bit meanings are for the standard model. Specifications may differ by date of manufacture (Function manual p.399 NOTE)."},{"ko":"누적 전력량 40225 는 뺐다 — 모니터 항목표의 Modbus 칸은 0.01 kWh 인데, 같은 매뉴얼의 누적 전력 절(p.402 (PDF 403))은 통신으로 읽을 때 1 kWh 단위(Pr.170 에 따라 0~9999 또는 0~65535 kWh)로 적어 서로 다르다. 단위가 표에 분명한 32비트 누적 전력량(40277~40280)을 대신 넣었다.","en":"Cumulative energy 40225 is left out: the Modbus column of the monitor list says 0.01 kWh, but the cumulative power section of the same manual (p.402 (PDF 403)) gives 1 kWh increments via communication (0-9999 or 0-65535 kWh by Pr.170). The 32-bit cumulative energy registers (40277-40280), whose units are explicit, are included instead."}],"sources":[{"title":"FR-E800 Instruction Manual (Communication)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600871ENG-S","en":"IB(NA)-0600871ENG-S"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600871eng/ib0600871engs.pdf","pages":{"ko":"3.5 MODBUS RTU p.257 (PDF 258)~p.267 (PDF 268)","en":"3.5 MODBUS RTU p.257 (PDF 258) to p.267 (PDF 268)"},"checked":"2026-10-23"},{"title":"FR-E800 Instruction Manual (Function)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600868ENG-U","en":"IB(NA)-0600868ENG-U"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600868eng/ib0600868engu.pdf","pages":{"ko":"Pr.52 모니터 항목표 p.395~399 (PDF 396~400), Pr.7·Pr.21 p.302 (PDF 303), 누적 전력 p.402 (PDF 403)","en":"Pr.52 monitor item list pp.395-399 (PDF 396-400), Pr.7/Pr.21 p.302 (PDF 303), cumulative power p.402 (PDF 403)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-f700","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-F700","models":["FR-F720-0.75K~110K","FR-F740-0.75K~560K"],"kind":"inverter","title":{"ko":"미쓰비시전기 FR-F700 인버터 (RS-485 단자 Modbus RTU)","en":"Mitsubishi Electric FR-F700 inverter (RS-485 terminals Modbus RTU)"},"summary":{"ko":"팬·펌프용 인버터. RS-485 단자 Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~40508, 파라미터 41000+번호","en":"Fan and pump inverter. RS-485 terminals Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-40508, parameters 41000 + number"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[300,600,1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.212 (PDF 221))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고(응답 … 17 70 0B B8 03 E8 2C E6 = 60·30·10 Hz), 쓰기 예(p.213 (PDF 222))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.215 (PDF 224))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.212 (PDF 221)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6) (reply ... 17 70 0B B8 03 E8 2C E6 = 60/30/10 Hz); the write example (p.213 (PDF 222)) 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.215 (PDF 224)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). RS-485 단자 쪽 설정이다: Pr.331 국번 초기값 0 은 브로드캐스트라 응답이 없으니 1~247 로, Pr.332 초기값 96 = 9600 bps, Pr.334 초기값 2 = 짝수 패리티·정지 1비트, 데이터 8비트 고정 (p.209 (PDF 218)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). These are the RS-485 terminal settings: Pr.331 station default 0 is broadcast (no reply), so set 1-247; Pr.332 default 96 = 9600 bps; Pr.334 default 2 = even parity, 1 stop bit; 8 data bits fixed (p.209 (PDF 218))."},{"ko":"함수 코드 03·06·08·10·46. 읽기 개수는 매뉴얼 본문이 최대 125개라고 하면서 응답 바이트 수 범위를 2~20(10개)으로 적어 서로 맞지 않는다(p.212 (PDF 221)) — 한 번에 많이 읽을 때는 장비로 확인. 쓰기는 125개까지.","en":"Function codes 03, 06, 08, 10, 46. For reads the manual says up to 125 registers but lists the reply byte count as 2-20 (10 registers), which disagree (p.212 (PDF 221)); check on the device before reading large blocks. Writes up to 125."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 중","en":"Write: forward rotation / Read: forward running"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 중","en":"Write: reverse rotation / Read: reverse running"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하)","en":"Write: RM (middle speed) / Read: OL (overload)"},{"bit":5,"ko":"쓰기: RL(저속) / 읽기: IPF(순간 정전)","en":"Write: RL (low speed) / Read: IPF (instantaneous power failure)"},{"bit":6,"ko":"쓰기: JOG(조그) / 읽기: FU(주파수 검출)","en":"Write: JOG (jog) / Read: FU (frequency detection)"},{"bit":7,"ko":"쓰기: RT(제2 기능) / 읽기: ABC1(고장)","en":"Write: RT (second function) / Read: ABC1 (fault)"},{"bit":8,"ko":"쓰기: AU(전류 입력 선택) / 읽기: ABC2","en":"Write: AU (current input selection) / Read: ABC2"},{"bit":9,"ko":"쓰기: CS(순간 정전 후 재시동 선택)","en":"Write: CS (automatic restart after instantaneous power failure)"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":11,"ko":"쓰기: STOP(기동 자기유지)","en":"Write: STOP (start self-holding)"},{"bit":12,"ko":"쓰기: RES(리셋)","en":"Write: RES (reset)"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~189, 출력은 Pr.190~196 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in parentheses are initial assignments; inputs follow Pr.180-189, outputs Pr.190-196"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0014h = NET (PU 쓰기 값은 표에 없음)","en":"Values are the read mode. Write: 0010h = EXT, 0014h = NET (no PU write value in the table)"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"설정 주파수(RAM)","en":"Set frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"Pr.37·Pr.144 에 따라 회전 속도(r/min) 단위로 바뀐다. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"Changes to r/min units depending on Pr.37/Pr.144. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"설정 주파수(EEPROM)","en":"Set frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 4)에서 0.01 Hz. Pr.37·Pr.144 조합에 따라 회전 속도(r/min)·기계 속도(1 단위)로 바뀐다(p.130 (PDF 139))","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 4); changes to r/min or machine speed (increment 1) depending on Pr.37/Pr.144 (p.130 (PDF 139))"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-F720-55K·FR-F740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-F720-55K·FR-F740-55K); 0.1 for 75K or higher"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 4)에서 0.01 Hz. Pr.37·Pr.144 조합에 따라 회전 속도(r/min)·기계 속도(1 단위)로 바뀐다(p.130 (PDF 139))","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 4); changes to r/min or machine speed (increment 1) depending on Pr.37/Pr.144 (p.130 (PDF 139))"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":205,"manualAddress":"40206","type":"u16","name":{"ko":"운전 속도","en":"Running speed"},"unit":"r/min","access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":208,"manualAddress":"40209","type":"u16","name":{"ko":"회생 제동 사용률","en":"Regenerative brake duty"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal relay function load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크값","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-F720-55K·FR-F740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-F720-55K·FR-F740-55K); 0.1 for 75K or higher"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":211,"manualAddress":"40212","type":"u16","name":{"ko":"컨버터 출력 전압 피크값","en":"Converter output voltage peak value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":212,"manualAddress":"40213","type":"u16","name":{"ko":"입력 전력","en":"Input power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-F720-55K·FR-F740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-F720-55K·FR-F740-55K); 0.1 for 75K or higher"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 55K 이하(FR-F720-55K·FR-F740-55K), 75K 이상은 0.1 단위","en":"0.01 increments for 55K or lower (FR-F720-55K·FR-F740-55K); 0.1 for 75K or higher"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":2,"ko":"AU","en":"AU"},{"bit":3,"ko":"RT","en":"RT"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"},{"bit":7,"ko":"JOG","en":"JOG"},{"bit":8,"ko":"MRS","en":"MRS"},{"bit":9,"ko":"STOP","en":"STOP"},{"bit":10,"ko":"RES","en":"RES"},{"bit":11,"ko":"CS","en":"CS"}],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":1,"ko":"SU","en":"SU"},{"bit":2,"ko":"IPF","en":"IPF"},{"bit":3,"ko":"OL","en":"OL"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC1","en":"ABC1"},{"bit":6,"ko":"ABC2","en":"ABC2"}],"description":{"ko":"1 = ON","en":"1 = ON"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":216,"manualAddress":"40217","type":"u16","name":{"ko":"로드 미터","en":"Load meter"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.563)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.563)"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.564)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.564)"},"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":224,"manualAddress":"40225","type":"u16","name":{"ko":"누적 전력량","en":"Cumulative power"},"unit":"kWh","access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":251,"manualAddress":"40252","type":"u16","name":{"ko":"PID 목표값","en":"PID set point"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":252,"manualAddress":"40253","type":"u16","name":{"ko":"PID 측정값","en":"PID measured value"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":253,"manualAddress":"40254","type":"u16","name":{"ko":"PID 편차","en":"PID deviation"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.217 (PDF 226)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault history 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh). Writing any value clears the whole fault history"},"ref":"p.219 (PDF 228)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault history 2"},"access":"r","fc":[3],"description":{"ko":"40508(고장 이력 8)까지 같은 형식","en":"Same format up to 40508 (fault history 8)"},"ref":"p.219 (PDF 228)","source":0},{"table":"holding-registers","address":1003,"manualAddress":"41004","type":"u16","name":{"ko":"다단 속도 고속(Pr.4)","en":"Multi-speed setting, high speed (Pr.4)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 1770h = 60.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 1770h = 60.00 Hz"},"ref":"p.212 (PDF 221)","source":0},{"table":"holding-registers","address":1004,"manualAddress":"41005","type":"u16","name":{"ko":"다단 속도 중속(Pr.5)","en":"Multi-speed setting, middle speed (Pr.5)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 0BB8h = 30.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 0BB8h = 30.00 Hz"},"ref":"p.212 (PDF 221)","source":0},{"table":"holding-registers","address":1005,"manualAddress":"41006","type":"u16","name":{"ko":"다단 속도 저속(Pr.6)","en":"Multi-speed setting, low speed (Pr.6)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 매뉴얼 읽기 예 응답: 03E8h = 10.00 Hz","en":"Register = parameter number + 41000. Manual read example reply: 03E8h = 10.00 Hz"},"ref":"p.212 (PDF 221)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s(p.96 (PDF 105)). 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1 (p.96 (PDF 105)). Manual FC10 example: 0.5 s = 0005h"},"ref":"p.215 (PDF 224)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 1 s = 000Ah"},"ref":"p.215 (PDF 224)","source":0}],"notes":[{"ko":"전류·전력 배율은 55K 이하 기준(scale 0.01). 75K 이상은 0.1 단위다. 누적 전력량(40225)은 1 kWh 단위.","en":"Current and power scales are for 55K or lower (scale 0.01); 75K or higher use 0.1 increments. Cumulative power (40225) is in 1 kWh."},{"ko":"단자 비트는 초기 할당 기준(입력은 Pr.180~189, 출력은 Pr.190~196 에 따라 바뀐다).","en":"Terminal bits are for the initial assignments (inputs follow Pr.180-189, outputs Pr.190-196)."}],"sources":[{"title":"FR-F700 INSTRUCTION MANUAL (Applied)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600177ENG-F","en":"IB(NA)-0600177ENG-F"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600177eng/ib0600177engf.pdf","pages":{"ko":"Modbus-RTU p.209 (PDF 218)~p.219 (PDF 228), Pr.37·Pr.144 p.130 (PDF 139), Pr.7·Pr.21 p.96 (PDF 105)","en":"Modbus-RTU p.209 (PDF 218) to p.219 (PDF 228), Pr.37/Pr.144 p.130 (PDF 139), Pr.7/Pr.21 p.96 (PDF 105)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"mitsubishi-electric/fr-f800","manufacturer":{"ko":"미쓰비시전기","en":"Mitsubishi Electric"},"model":"FR-F800","kind":"inverter","title":{"ko":"미쓰비시전기 FR-F800 인버터 (RS-485 단자 Modbus RTU)","en":"Mitsubishi Electric FR-F800 inverter (RS-485 terminals Modbus RTU)"},"summary":{"ko":"RS-485 단자 Modbus RTU. 홀딩 레지스터 40001~ 꼴: 시스템 변수 40002~, 실시간 모니터 40201~, 고장 이력 40501~40508, 파라미터 41000+번호, 형명·용량 44001~","en":"RS-485 terminals Modbus RTU. Holding registers in 40001 form: system variables 40002-, real-time monitor 40201-, fault history 40501-40508, parameters 41000 + number, model and capacity 44001-"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[300,600,1200,2400,4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":125,"addressing":"plc","notes":[{"ko":"주소 체계: 읽기 예(p.531 (PDF 532))는 11 03 03 EB 00 03 77 2B 로 41004~41006(Pr.4~6)을 읽고, 쓰기 예(p.532 (PDF 533))는 05 06 00 0D 17 70 17 99 로 40014 에 60 Hz 를 쓴다. FC10 예(p.534 (PDF 535))는 19 10 03 EE 00 02 04 00 05 00 0A 86 3D 로 41007·41008 에 쓴다. 프레임 주소 = 매뉴얼 번호 − 40001. CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.531 (PDF 532)) sends 11 03 03 EB 00 03 77 2B to read 41004-41006 (Pr.4-6); the write example (p.532 (PDF 533)) 05 06 00 0D 17 70 17 99 writes 60 Hz to 40014; the FC10 example (p.534 (PDF 535)) 19 10 03 EE 00 02 04 00 05 00 0A 86 3D writes 41007 and 41008. Frame address = manual number - 40001. CRCs match calculation."},{"ko":"Modbus RTU 로 쓰려면 Pr.549 = 1(초기값 0 = 미쓰비시 프로토콜). PU 커넥터가 아니라 RS-485 단자 쪽 설정이다: Pr.331 국번 초기값 0 은 브로드캐스트라 응답이 없으니 1~247 로, Pr.332 초기값 96 = 9600 bps, Pr.334 초기값 2 = 짝수 패리티·정지 1비트(Pr.333 정지 비트는 Pr.334 = 0 일 때만), 데이터 8비트 고정 (p.527-528 (PDF 528-529)).","en":"To use Modbus RTU set Pr.549 = 1 (default 0 = Mitsubishi protocol). These are the RS-485 terminal settings, not the PU connector: Pr.331 station default 0 is broadcast (no reply), so set 1-247; Pr.332 default 96 = 9600 bps; Pr.334 default 2 = even parity, 1 stop bit (Pr.333 stop bits apply only when Pr.334 = 0); 8 data bits fixed (p.527-528 (PDF 528-529))."},{"ko":"함수 코드 03·06·08·10·46. 한 번에 125개까지 읽기·쓰기. 통신 옵션이 달려 있고 Pr.550 = 9999(초기값)이면 RS-485 단자의 운전 명령은 무효.","en":"Function codes 03, 06, 08, 10, 46. Up to 125 registers per read/write. With a communication option installed and Pr.550 = 9999 (initial), operation commands via the RS-485 terminals are invalid."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"40002","type":"u16","name":{"ko":"인버터 리셋","en":"Inverter reset"},"access":"w","fc":[6,16],"description":{"ko":"아무 값이나 쓴다. 리셋 명령에는 응답이 없다","en":"Write any value. No reply to the reset command"},"ref":"p.536 (PDF 537)","source":0},{"table":"holding-registers","address":8,"manualAddress":"40009","type":"u16","name":{"ko":"인버터 상태 / 제어 입력 명령","en":"Inverter status / control input command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"쓰기: 정지 / 읽기: RUN(운전 중)","en":"Write: stop / Read: RUN (running)"},{"bit":1,"ko":"쓰기: 정회전 / 읽기: 정회전 출력","en":"Write: forward rotation / Read: forward rotation output"},{"bit":2,"ko":"쓰기: 역회전 / 읽기: 역회전 출력","en":"Write: reverse rotation / Read: reverse rotation output"},{"bit":3,"ko":"쓰기: RH(고속) / 읽기: SU(주파수 도달)","en":"Write: RH (high speed) / Read: SU (up to frequency)"},{"bit":4,"ko":"쓰기: RM(중속) / 읽기: OL(과부하)","en":"Write: RM (middle speed) / Read: OL (overload)"},{"bit":5,"ko":"쓰기: RL(저속) / 읽기: IPF(순간 정전)","en":"Write: RL (low speed) / Read: IPF (instantaneous power failure)"},{"bit":6,"ko":"쓰기: JOG(조그 운전) / 읽기: FU(주파수 검출)","en":"Write: JOG (jog operation) / Read: FU (frequency detection)"},{"bit":7,"ko":"쓰기: RT(제2 기능 선택) / 읽기: ABC1(고장)","en":"Write: RT (second function selection) / Read: ABC1 (fault)"},{"bit":8,"ko":"쓰기: AU(전류 입력 선택) / 읽기: ABC2","en":"Write: AU (current input selection) / Read: ABC2"},{"bit":9,"ko":"쓰기: CS(기능 없음) / 읽기: 안전 모니터 출력","en":"Write: CS (no function) / Read: Safety monitor output"},{"bit":10,"ko":"쓰기: MRS(출력 정지)","en":"Write: MRS (output stop)"},{"bit":11,"ko":"쓰기: STP(STOP, 기동 자기 유지)","en":"Write: STP (STOP, start self-holding)"},{"bit":12,"ko":"쓰기: RES(리셋)","en":"Write: RES (inverter reset)"},{"bit":15,"ko":"읽기: 고장 발생","en":"Read: fault occurrence"}],"description":{"ko":"쓰면 제어 입력, 읽으면 인버터 상태. 괄호 안 신호는 초기 할당 — 입력은 Pr.180~189, 출력은 Pr.190~196 에 따라 바뀐다","en":"Write = control input, read = inverter status. Signals in brackets are initial assignments; inputs change with Pr.180-189, outputs with Pr.190-196"},"ref":"p.536 (PDF 537)","source":0},{"table":"holding-registers","address":9,"manualAddress":"40010","type":"u16","name":{"ko":"운전 모드 / 인버터 설정","en":"Operation mode / inverter setting"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"EXT","en":"EXT"},{"value":1,"ko":"PU","en":"PU"},{"value":2,"ko":"EXT JOG","en":"EXT JOG"},{"value":3,"ko":"PU JOG","en":"PU JOG"},{"value":4,"ko":"NET","en":"NET"},{"value":5,"ko":"PU+EXT","en":"PU+EXT"}],"description":{"ko":"값은 읽은 운전 모드. 쓰기 값: 0010h = EXT, 0011h = PU(Pr.79·Pr.340 에 따라), 0014h = NET","en":"Values are the read mode. Write: 0010h = EXT, 0011h = PU (depending on Pr.79/Pr.340), 0014h = NET"},"ref":"p.536 (PDF 537)","source":0},{"table":"holding-registers","address":13,"manualAddress":"40014","type":"u16","name":{"ko":"운전 주파수(RAM)","en":"Running frequency (RAM)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,6,16],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 2~12)에서 0.01 Hz. Pr.37·Pr.144 에 따라 회전 속도·기계 속도(1 단위)로 바뀐다. 매뉴얼 FC06 예: 60 Hz = 1770h","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 2-12); changes to rotation/machine speed (increment 1) depending on Pr.37/Pr.144. Manual FC06 example: 60 Hz = 1770h"},"ref":"p.536 (PDF 537)","source":0},{"table":"holding-registers","address":14,"manualAddress":"40015","type":"u16","name":{"ko":"운전 주파수(EEPROM)","en":"Running frequency (EEPROM)"},"unit":"Hz","scale":0.01,"access":"w","fc":[6,16],"ref":"p.536 (PDF 537)","source":0},{"table":"holding-registers","address":200,"manualAddress":"40201","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 2~12)에서 0.01 Hz. Pr.37·Pr.144 에 따라 회전 속도·기계 속도(1 단위)로 바뀐다","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 2-12); changes to rotation/machine speed (increment 1) depending on Pr.37/Pr.144"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":201,"manualAddress":"40202","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-F820-02330(55K)·FR-F840-01160(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-F820-02330 (55K) / FR-F840-01160 (55K) or lower; 0.1 for larger capacities"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":202,"manualAddress":"40203","type":"u16","name":{"ko":"출력 전압","en":"Output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":204,"manualAddress":"40205","type":"u16","name":{"ko":"설정 주파수","en":"Set frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"초기 설정(Pr.37 = 0, Pr.144 = 2~12)에서 0.01 Hz. Pr.37·Pr.144 에 따라 회전 속도·기계 속도(1 단위)로 바뀐다","en":"0.01 Hz with initial settings (Pr.37 = 0, Pr.144 = 2-12); changes to rotation/machine speed (increment 1) depending on Pr.37/Pr.144"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":205,"manualAddress":"40206","type":"u16","name":{"ko":"운전 속도","en":"Operation speed"},"unit":"r/min","access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":206,"manualAddress":"40207","type":"u16","name":{"ko":"모터 토크","en":"Motor torque"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":207,"manualAddress":"40208","type":"u16","name":{"ko":"컨버터 출력 전압","en":"Converter output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":209,"manualAddress":"40210","type":"u16","name":{"ko":"전자 서멀 부하율","en":"Electronic thermal O/L relay load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":210,"manualAddress":"40211","type":"u16","name":{"ko":"출력 전류 피크값","en":"Output current peak value"},"unit":"A","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-F820-02330(55K)·FR-F840-01160(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-F820-02330 (55K) / FR-F840-01160 (55K) or lower; 0.1 for larger capacities"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":211,"manualAddress":"40212","type":"u16","name":{"ko":"컨버터 출력 전압 피크값","en":"Converter output voltage peak value"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":212,"manualAddress":"40213","type":"u16","name":{"ko":"입력 전력","en":"Input power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-F820-02330(55K)·FR-F840-01160(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-F820-02330 (55K) / FR-F840-01160 (55K) or lower; 0.1 for larger capacities"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":213,"manualAddress":"40214","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"unit":"kW","scale":0.01,"access":"r","fc":[3],"description":{"ko":"0.01 단위는 FR-F820-02330(55K)·FR-F840-01160(55K) 이하, 그보다 큰 용량은 0.1 단위","en":"0.01 increments for FR-F820-02330 (55K) / FR-F840-01160 (55K) or lower; 0.1 for larger capacities"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":214,"manualAddress":"40215","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"STF","en":"STF"},{"bit":1,"ko":"STR","en":"STR"},{"bit":2,"ko":"AU","en":"AU"},{"bit":3,"ko":"RT","en":"RT"},{"bit":4,"ko":"RL","en":"RL"},{"bit":5,"ko":"RM","en":"RM"},{"bit":6,"ko":"RH","en":"RH"},{"bit":7,"ko":"JOG","en":"JOG"},{"bit":8,"ko":"MRS","en":"MRS"},{"bit":9,"ko":"STP (STOP)","en":"STP (STOP)"},{"bit":10,"ko":"RES","en":"RES"},{"bit":11,"ko":"CS","en":"CS"},{"bit":14,"ko":"S2","en":"S2"},{"bit":15,"ko":"S1","en":"S1"}],"ref":"p.311, p.313 (PDF 312, 314)","source":0},{"table":"holding-registers","address":215,"manualAddress":"40216","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"RUN","en":"RUN"},{"bit":1,"ko":"SU","en":"SU"},{"bit":2,"ko":"IPF","en":"IPF"},{"bit":3,"ko":"OL","en":"OL"},{"bit":4,"ko":"FU","en":"FU"},{"bit":5,"ko":"ABC1","en":"ABC1"},{"bit":6,"ko":"ABC2","en":"ABC2"},{"bit":7,"ko":"SO","en":"SO"}],"ref":"p.311, p.313 (PDF 312, 314)","source":0},{"table":"holding-registers","address":219,"manualAddress":"40220","type":"u16","name":{"ko":"누적 통전 시간","en":"Cumulative energization time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.563)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.563)"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":222,"manualAddress":"40223","type":"u16","name":{"ko":"실 운전 시간","en":"Actual operation time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0~65535 시간 누적 후 0 부터 다시(넘친 횟수는 Pr.564)","en":"Accumulates 0-65535 h, then restarts from 0 (overflow count in Pr.564)"},"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":223,"manualAddress":"40224","type":"u16","name":{"ko":"모터 부하율","en":"Motor load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.310 (PDF 311)","source":0},{"table":"holding-registers","address":260,"manualAddress":"40261","type":"u16","name":{"ko":"모터 서멀 부하율","en":"Motor thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.311 (PDF 312)","source":0},{"table":"holding-registers","address":261,"manualAddress":"40262","type":"u16","name":{"ko":"인버터 서멀 부하율","en":"Inverter thermal load factor"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.311 (PDF 312)","source":0},{"table":"holding-registers","address":276,"manualAddress":"40277","type":"u32","order":"CDAB","name":{"ko":"32비트 누적 전력량(kWh)","en":"32-bit cumulative energy (kWh)"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"40277 = 하위 16비트, 40278 = 상위 16비트(워드 바꿈 CDAB)","en":"40277 = lower 16 bits, 40278 = upper 16 bits (word swap, CDAB)"},"ref":"p.312 (PDF 313)","source":0},{"table":"holding-registers","address":278,"manualAddress":"40279","type":"u32","order":"CDAB","name":{"ko":"32비트 누적 전력량(0.01 kWh)","en":"32-bit cumulative energy (0.01 kWh)"},"unit":"kWh","scale":0.01,"access":"r","fc":[3],"description":{"ko":"40279 = 하위 16비트, 40280 = 상위 16비트(워드 바꿈 CDAB). 0.01 kWh 는 FR-F820-02330(55K)·FR-F840-01160(55K) 이하, 그보다 큰 용량은 0.1 kWh","en":"40279 = lower 16 bits, 40280 = upper 16 bits (word swap, CDAB). 0.01 kWh for FR-F820-02330(55K) / FR-F840-01160(55K) or lower; 0.1 kWh for larger capacities"},"ref":"p.312 (PDF 313)","source":0},{"table":"holding-registers","address":500,"manualAddress":"40501","type":"u16","name":{"ko":"고장 이력 1(최신)","en":"Fault record 1 (latest)"},"access":"rw","fc":[3,6,16],"description":{"ko":"하위 바이트가 고장 코드(00xxh). 아무 값이나 쓰면 고장 이력 전체 삭제","en":"Low byte is the fault code (00xxh). Writing any value clears the whole fault history"},"ref":"p.538 (PDF 539)","source":0},{"table":"holding-registers","address":501,"manualAddress":"40502","type":"u16","name":{"ko":"고장 이력 2","en":"Fault record 2"},"access":"r","fc":[3],"description":{"ko":"40508(고장 이력 8)까지 같은 형식","en":"Same format up to 40508 (fault record 8)"},"ref":"p.538 (PDF 539)","source":0},{"table":"holding-registers","address":1006,"manualAddress":"41007","type":"u16","name":{"ko":"가속 시간(Pr.7)","en":"Acceleration time (Pr.7)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"파라미터 번호 + 41000 = 레지스터. 0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 0.5 s = 0005h","en":"Register = parameter number + 41000. 0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 0.5 s = 0005h"},"ref":"p.534 (PDF 535)","source":0},{"table":"holding-registers","address":1007,"manualAddress":"41008","type":"u16","name":{"ko":"감속 시간(Pr.8)","en":"Deceleration time (Pr.8)"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.1 s 단위는 Pr.21 = 0(초기값)일 때 — Pr.21 = 1 이면 0.01 s. 매뉴얼 FC10 예: 1 s = 000Ah","en":"0.1 s units with Pr.21 = 0 (initial); 0.01 s with Pr.21 = 1. Manual FC10 example: 1 s = 000Ah"},"ref":"p.534 (PDF 535)","source":0},{"table":"holding-registers","address":4000,"manualAddress":"44001","type":"string","name":{"ko":"형명","en":"Model name"},"access":"r","fc":[3],"len":20,"description":{"ko":"ASCII 20자(44001~44010), 빈칸은 20h. 예 FR-F840-1 → 46h 52h 2Dh …","en":"ASCII, 20 characters (44001-44010), blanks are 20h. Example FR-F840-1 → 46h 52h 2Dh ..."},"ref":"p.538 (PDF 539)","source":0},{"table":"holding-registers","address":4010,"manualAddress":"44011","type":"string","name":{"ko":"용량","en":"Capacity"},"access":"r","fc":[3],"len":6,"description":{"ko":"ASCII 6자(44011~44013), 0.1 kW 단위(0.01 kW 이하 버림), 빈칸은 20h. 예 0.75K → \"     7\"","en":"ASCII, 6 characters (44011-44013), in 0.1 kW (0.01 kW truncated), blanks are 20h. Example 0.75K → \"     7\""},"ref":"p.538 (PDF 539)","source":0}],"notes":[{"ko":"모니터 레지스터(40201~)는 모니터 항목표의 «MODBUS RTU» 칸에서 옮겼다. 그 표의 음수 표시(○)는 Modbus RTU 통신에서는 쓸 수 없어 모두 부호 없는 16비트로 적었다.","en":"Monitor registers (40201-) are taken from the 'MODBUS RTU' column of the monitor item list. Negative indication (○) in that table is not available over Modbus RTU, so all are listed as unsigned 16-bit."},{"ko":"전류·전력 배율은 FR-F820-02330(55K)·FR-F840-01160(55K) 이하 기준(scale 0.01). 그보다 큰 용량은 0.1 단위다.","en":"Current and power scales are for FR-F820-02330 (55K) / FR-F840-01160 (55K) or lower (scale 0.01); larger capacities use 0.1 increments."},{"ko":"누적 전력량 40225 는 뺐다 — 모니터 항목표의 Modbus 칸은 0.01 kWh 인데, 같은 매뉴얼의 누적 전력 절(p.315 (PDF 316))은 통신으로 읽을 때 1 kWh 단위(Pr.170 에 따라 0~9999 또는 0~65535 kWh)로 적어 서로 다르다. 단위가 표에 분명한 32비트 누적 전력량(40277~40280)을 대신 넣었다.","en":"Cumulative energy 40225 is left out: the Modbus column of the monitor list says 0.01 kWh, but the cumulative power section of the same manual (p.315 (PDF 316)) gives 1 kWh increments via communication (0-9999 or 0-65535 kWh by Pr.170). The 32-bit cumulative energy registers (40277-40280), whose units are explicit, are included instead."}],"sources":[{"title":"FR-F800 INSTRUCTION MANUAL (DETAILED)","publisher":"Mitsubishi Electric Corporation","edition":{"ko":"IB(NA)-0600547ENG-G","en":"IB(NA)-0600547ENG-G"},"url":"https://dl.mitsubishielectric.com/dl/fa/document/manual/inv/ib0600547eng/ib0600547engg.pdf","pages":{"ko":"Modbus RTU p.527 (PDF 528)~p.538 (PDF 539), 표시 단위(Pr.37·Pr.144) p.308 (PDF 309), 모니터 항목표 p.310-313 (PDF 311-314), Pr.7·Pr.21 p.229 (PDF 230), 누적 전력 p.315 (PDF 316)","en":"Modbus RTU p.527 (PDF 528) to p.538 (PDF 539), indication increments (Pr.37/Pr.144) p.308 (PDF 309), monitor item list pp.310-313 (PDF 311-314), Pr.7/Pr.21 p.229 (PDF 230), cumulative power p.315 (PDF 316)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"omron/3g3jx","manufacturer":{"ko":"오므론","en":"OMRON"},"model":"3G3JX","kind":"inverter","title":{"ko":"오므론 3G3JX 인버터 (내장 RS-485 Modbus RTU)","en":"OMRON 3G3JX inverter (built-in RS-485 Modbus RTU)"},"summary":{"ko":"RJ45 커넥터의 RS-485 Modbus RTU(C070 = 03, 선택 스위치 S7 = 485). 코일 0001h~(운전·상태), 보유 레지스터 0002h~(지령·트립 이력), 1002h~(d 모니터·F·A 파라미터), 116Ah~(d018·d102·d104). 매뉴얼 번호 − 1 = 프레임 주소","en":"RS-485 Modbus RTU on the RJ45 connector (C070 = 03, selector S7 = 485). Coils from 0001h (run, status), holding registers from 0002h (commands, trip history), 1002h (d monitors, F/A parameters), 116Ah (d018, d102, d104). Manual number - 1 = frame address"},"protocols":["rtu"],"comm":{"baud":4800,"bauds":[4800,9600,19200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,32],"order":"ABCD","addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼의 코일·레지스터 번호는 1 기준이고 예마다 «시작 주소는 번호보다 1 작다» 주석이 있다 (p.4-83~4-89). 예: 코일 읽기(p.4-83) 08 01 00 06 00 05 1C 91 → 코일 0007h~(다기능 입력 1~), 레지스터 읽기(p.4-84~4-85) 01 03 00 11 00 06 95 CD → 0012h~0017h(트립 모니터 1), 코일 쓰기(p.4-86) 08 05 00 00 FF 00 8C A3 → 코일 0001h(운전 지령), FC06(p.4-86~4-87) 08 06 10 28 01 F4 0D 8C → 1029h(A020)에 500, FC10(p.4-88~4-89) 08 10 10 13 00 02 04 00 04 93 E0 7D 53 → 1014h·1015h(F002)에 300000. 이 프레임들과 응답(08 01 01 05 92 17, 01 03 0C 00 03 00 00 00 63 00 00 00 1E 01 1C AF 6D, 08 0F 00 06 00 05 75 50, 08 10 10 13 00 02 B4 54)·코일 여러 개 쓰기(08 0F 00 06 00 05 02 17 00 83 EA)의 CRC 는 모두 계산값과 같다.","en":"Addressing: coil and register numbers in the manual are 1-based, and each example notes «the start address is 1 smaller than the number» (pp.4-83 to 4-89). Examples: read coils (p.4-83) 08 01 00 06 00 05 1C 91 → coils from 0007h (multi-function input 1); read registers (pp.4-84 to 4-85) 01 03 00 11 00 06 95 CD → 0012h-0017h (trip monitor 1); write coil (p.4-86) 08 05 00 00 FF 00 8C A3 → coil 0001h (RUN command); FC06 (pp.4-86 to 4-87) 08 06 10 28 01 F4 0D 8C → 500 to 1029h (A020); FC10 (pp.4-88 to 4-89) 08 10 10 13 00 02 04 00 04 93 E0 7D 53 → 300000 to 1014h/1015h (F002). The CRCs of these frames, of the responses (08 01 01 05 92 17; 01 03 0C 00 03 00 00 00 63 00 00 00 1E 01 1C AF 6D; 08 0F 00 06 00 05 75 50; 08 10 10 13 00 02 B4 54) and of write coils (08 0F 00 06 00 05 02 17 00 83 EA) all match calculation."},{"ko":"함수 코드 01h·03h·05h·06h·08h·0Fh·10h, 02h·04h 없음 — 읽기 전용 상태도 코일(01h)로 읽는다. 함수 코드 표(p.4-81)는 03h·10h 를 한 번에 레지스터 4개(8바이트)까지로 적지만 같은 매뉴얼 읽기 예(p.4-84)는 6개(0Ch 바이트)를 읽어 maxRegisters 는 비웠다 — 4개 이하로 읽으면 안전하다.","en":"Function codes 01h, 03h, 05h, 06h, 08h, 0Fh and 10h; no 02h/04h, so read-only status is read as coils (01h). The function code table (p.4-81) limits 03h/10h to 4 registers (8 bytes), but the read example in the same manual (p.4-84) reads 6 (0Ch bytes), so maxRegisters is left empty; reading 4 or fewer is safe."},{"ko":"출하값: C070 02 = 오퍼레이터(Modbus 는 03), C071 04 = 4800 bps, C072 국번 1(1~32), C074 00 = 패리티 없음, C075 1 = 정지 1비트, 데이터 8비트 고정 (p.4-77, p.4-79). C07x 는 Modbus 로 바꿀 수 없고 오퍼레이터로만 설정, 바꾼 뒤 전원을 다시 넣는다. 485/OPE 선택 스위치 S7 을 485 로 (p.4-78). 종단 저항은 내장되어 있지 않다.","en":"Defaults: C070 02 = operator (03 for Modbus), C071 04 = 4800 bps, C072 station 1 (1-32), C074 00 = no parity, C075 1 = 1 stop bit, 8 data bits fixed (pp.4-77, 4-79). C07x cannot be changed through Modbus; set them on the operator and cycle power. Set the 485/OPE selector S7 to 485 (p.4-78). No built-in termination resistor."},{"ko":"32비트 값은 (MSB) 번호가 앞, (LSB) 번호가 뒤 — 상위 워드 먼저(ABCD). FC10 예(p.4-89)도 1014h 에 0004h, 1015h 에 93E0h 를 쓴다.","en":"32-bit values have the (MSB) number first and the (LSB) number next, i.e. high word first (ABCD). The FC10 example (p.4-89) also writes 0004h to 1014h and 93E0h to 1015h."}]},"notes":[{"ko":"쪽 번호는 인쇄 쪽(4장은 PDF 쪽 = 4-xxx 의 xxx + 85, 예 p.4-92 = PDF 177).","en":"Page numbers are printed pages (in chapter 4, PDF page = xxx of 4-xxx + 85, e.g. p.4-92 = PDF 177)."},{"ko":"통신으로 운전·주파수를 주려면 A002 = 03, A001 = 03 (p.4-79, p.4-86).","en":"To run and set frequency by communication set A002 = 03 and A001 = 03 (pp.4-79, 4-86)."},{"ko":"출력 전류(d002, 1003h)·출력 전압(d013, 100Ch)은 넣지 않았다 — 통신 표(p.4-92~4-93)는 0.1 %·0.01 % 단위로 적지만 같은 매뉴얼 모니터 목록은 A·V 로 적어 단위가 어긋난다.","en":"Output current (d002, 1003h) and output voltage (d013, 100Ch) are not included: the communication table (pp.4-92 to 4-93) gives 0.1 % and 0.01 % units, while the monitor list in the same manual gives A and V."},{"ko":"트립 요인(0012h) 코드의 뜻은 통신 절에 표가 없어 values 를 비웠다 — 예(p.4-85)는 0003h 를 E03 으로 읽는다. 통신 설정 C070~C078(1137h~113Fh)은 표에 «Modbus 로 바꾸지 말 것» 이라 넣지 않았다 (p.4-104).","en":"Trip factor (0012h) codes have no table in the communication section, so values are left empty; the example (p.4-85) reads 0003h as E03. Communication settings C070-C078 (1137h-113Fh) are marked «Do not change through ModBus» and are not included (p.4-104)."},{"ko":"통신으로 쓴 값은 RAM 에만 있다. 남기려면 0900h 에 아무 값이나 쓴다(Enter 명령, p.4-90).","en":"Values written by communication are in RAM only. To keep them write any value to 0900h (Enter command, p.4-90)."}],"registers":[{"table":"coils","address":0,"manualAddress":"0001h","type":"bit","name":{"ko":"운전 지령","en":"RUN command"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 운전, 0 = 정지. A002 = 03 일 때 유효","en":"1 = run, 0 = stop. Valid when A002 = 03"},"ref":"p.4-91, p.4-86","source":0},{"table":"coils","address":1,"manualAddress":"0002h","type":"bit","name":{"ko":"회전 방향 지령","en":"Rotation direction command"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 역회전, 0 = 정회전. A002 = 03 일 때 유효","en":"1 = reverse, 0 = forward. Valid when A002 = 03"},"ref":"p.4-91","source":0},{"table":"coils","address":2,"manualAddress":"0003h","type":"bit","name":{"ko":"외부 트립(EXT)","en":"External trip (EXT)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 트립","en":"1 = trip"},"ref":"p.4-91","source":0},{"table":"coils","address":3,"manualAddress":"0004h","type":"bit","name":{"ko":"트립 리셋(RS)","en":"Trip reset (RS)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 리셋","en":"1 = reset"},"ref":"p.4-91","source":0},{"table":"coils","address":6,"manualAddress":"0007h","type":"bit","name":{"ko":"다기능 입력 1","en":"Multi-function input 1"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대 입력이 우선. 입력 2~5 는 코일 0008h~000Bh","en":"1 = ON. The control terminal block has priority. Inputs 2-5 are coils 0008h-000Bh"},"ref":"p.4-91, p.4-83","source":0},{"table":"coils","address":13,"manualAddress":"000Eh","type":"bit","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[1],"description":{"ko":"1 = 운전, 0 = 정지(d003 와 연동)","en":"1 = run, 0 = stop (interlocked with d003)"},"ref":"p.4-91","source":0},{"table":"coils","address":14,"manualAddress":"000Fh","type":"bit","name":{"ko":"회전 방향","en":"Rotation direction"},"access":"r","fc":[1],"description":{"ko":"1 = 역회전, 0 = 정회전(d003 와 연동)","en":"1 = reverse, 0 = forward (interlocked with d003)"},"ref":"p.4-91","source":0},{"table":"coils","address":15,"manualAddress":"0010h","type":"bit","name":{"ko":"인버터 준비","en":"Inverter ready"},"access":"r","fc":[1],"description":{"ko":"1 = 준비, 0 = 준비 안 됨","en":"1 = ready, 0 = not ready"},"ref":"p.4-91","source":0},{"table":"coils","address":19,"manualAddress":"0014h","type":"bit","name":{"ko":"알람 신호","en":"Alarm signal"},"access":"r","fc":[1],"description":{"ko":"1 = 트립 중, 0 = 정상","en":"1 = during trip, 0 = normal"},"ref":"p.4-91","source":0},{"table":"coils","address":21,"manualAddress":"0016h","type":"bit","name":{"ko":"과부하 예고 신호","en":"Overload warning signal"},"access":"r","fc":[1],"ref":"p.4-92","source":0},{"table":"coils","address":22,"manualAddress":"0017h","type":"bit","name":{"ko":"주파수 도달(설정 이상)","en":"Frequency arrival signal (over set frequency)"},"access":"r","fc":[1],"ref":"p.4-92","source":0},{"table":"coils","address":23,"manualAddress":"0018h","type":"bit","name":{"ko":"주파수 도달(정속)","en":"Frequency arrival signal (at a constant speed)"},"access":"r","fc":[1],"ref":"p.4-92","source":0},{"table":"coils","address":24,"manualAddress":"0019h","type":"bit","name":{"ko":"운전 중 신호","en":"Signal during RUN"},"access":"r","fc":[1],"ref":"p.4-92","source":0},{"table":"coils","address":25,"manualAddress":"001Ah","type":"bit","name":{"ko":"데이터 쓰는 중","en":"Data writing"},"access":"r","fc":[1],"description":{"ko":"1 = 쓰는 중(Enter 명령 진행 확인용), 0 = 정상","en":"1 = writing (use to watch the Enter command), 0 = normal"},"ref":"p.4-92, p.4-90","source":0},{"table":"holding-registers","address":1,"manualAddress":"0002h","type":"u16","name":{"ko":"주파수 지령","en":"Frequency reference"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":400},"description":{"ko":"A001 = 03 일 때 유효","en":"Valid when A001 = 03"},"ref":"p.4-92","source":0},{"table":"holding-registers","address":2,"manualAddress":"0003h","type":"u16","name":{"ko":"인버터 상태","en":"Inverter status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"초기","en":"Default"},{"value":2,"ko":"정지","en":"Stop"},{"value":3,"ko":"운전","en":"Run"},{"value":4,"ko":"프리런 정지(FRS)","en":"Free-run stop (FRS)"},{"value":5,"ko":"조그","en":"Jogging"},{"value":6,"ko":"직류 제동","en":"DC injection braking"},{"value":7,"ko":"재시도","en":"Retry"},{"value":8,"ko":"트립","en":"Trip"},{"value":9,"ko":"저전압","en":"Undervoltage"}],"ref":"p.4-92","source":0},{"table":"holding-registers","address":4,"manualAddress":"0005h","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"description":{"ko":"A076 = 02 일 때 유효","en":"Valid when A076 = 02"},"ref":"p.4-92","source":0},{"table":"holding-registers","address":16,"manualAddress":"0011h","type":"u16","name":{"ko":"트립 횟수(d080)","en":"Fault frequency monitor (d080)"},"access":"r","fc":[3],"description":{"ko":"0~65535 회","en":"0-65535 times"},"ref":"p.4-93","source":0},{"table":"holding-registers","address":17,"manualAddress":"0012h","type":"u16","name":{"ko":"트립 모니터 1 요인(d081)","en":"Trip monitor 1: factor code (d081)"},"access":"r","fc":[3],"description":{"ko":"가장 최근 트립. 읽기 예(p.4-84~4-85) 응답 0003h = E03(과전류). 트립 2·3 은 001Ch·0026h 부터 같은 꼴","en":"Latest trip. The read example (pp.4-84 to 4-85) returns 0003h = E03 (overcurrent). Trips 2 and 3 follow the same layout from 001Ch and 0026h"},"ref":"p.4-93, p.4-84","source":0},{"table":"holding-registers","address":19,"manualAddress":"0014h","type":"u16","name":{"ko":"트립 모니터 1 주파수","en":"Trip monitor 1: frequency"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"읽기 예 응답 0063h = 9.9 Hz","en":"Read example response 0063h = 9.9 Hz"},"ref":"p.4-93, p.4-85","source":0},{"table":"holding-registers","address":21,"manualAddress":"0016h","type":"u16","name":{"ko":"트립 모니터 1 전류","en":"Trip monitor 1: current"},"unit":"A","scale":0.1,"access":"r","fc":[3],"description":{"ko":"읽기 예 응답 001Eh = 3.0 A","en":"Read example response 001Eh = 3.0 A"},"ref":"p.4-93, p.4-85","source":0},{"table":"holding-registers","address":22,"manualAddress":"0017h","type":"u16","name":{"ko":"트립 모니터 1 전압","en":"Trip monitor 1: voltage"},"unit":"V","access":"r","fc":[3],"description":{"ko":"트립 때 직류(P-N) 전압. 읽기 예 응답 011Ch = 284 V","en":"DC (P-N) voltage at tripping. Read example response 011Ch = 284 V"},"ref":"p.4-93, p.4-85","source":0},{"table":"holding-registers","address":23,"manualAddress":"0018h","type":"u32","order":"ABCD","name":{"ko":"트립 모니터 1 누적 운전 시간","en":"Trip monitor 1: run time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"0018h 상위(MSB)·0019h 하위(LSB)","en":"0018h high (MSB), 0019h low (LSB)"},"ref":"p.4-93","source":0},{"table":"holding-registers","address":2303,"manualAddress":"0900h","type":"u16","name":{"ko":"Enter 명령(EEPROM 저장)","en":"Enter command"},"access":"w","fc":[6],"description":{"ko":"아무 값이나 06h 로 쓴다. 통신으로 쓴 값은 RAM 에만 있어 전원을 끄면 사라진다. 진행은 코일 001Ah 로 본다. EEPROM 수명 약 10만 회","en":"Write any value with 06h. Values written by communication stay in RAM and are lost at power off. Watch coil 001Ah for progress. EEPROM life about 100,000 writes"},"ref":"p.4-104, p.4-90","source":0},{"table":"holding-registers","address":4097,"manualAddress":"1002h","type":"u16","name":{"ko":"출력 주파수 모니터(d001)","en":"Output frequency monitor (d001)"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":400},"ref":"p.4-92","source":0},{"table":"holding-registers","address":4099,"manualAddress":"1004h","type":"u16","name":{"ko":"회전 방향 모니터(d003)","en":"Rotation direction monitor (d003)"},"access":"r","fc":[3],"values":[{"value":0,"ko":"정지","en":"Stop"},{"value":1,"ko":"정회전","en":"Forward"},{"value":2,"ko":"역회전","en":"Reverse"}],"ref":"p.4-92","source":0},{"table":"holding-registers","address":4102,"manualAddress":"1007h","type":"u16","name":{"ko":"다기능 입력 모니터(d005)","en":"Multi-function input monitor (d005)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"단자 1","en":"Terminal 1"},{"bit":1,"ko":"단자 2","en":"Terminal 2"},{"bit":2,"ko":"단자 3","en":"Terminal 3"},{"bit":3,"ko":"단자 4","en":"Terminal 4"},{"bit":4,"ko":"단자 5","en":"Terminal 5"}],"ref":"p.4-93","source":0},{"table":"holding-registers","address":4103,"manualAddress":"1008h","type":"u16","name":{"ko":"다기능 출력 모니터(d006)","en":"Multi-function output monitor (d006)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"P1","en":"P1"},{"bit":2,"ko":"MA","en":"MA"}],"ref":"p.4-93","source":0},{"table":"holding-registers","address":4109,"manualAddress":"100Eh","type":"u32","order":"ABCD","name":{"ko":"누적 운전 시간(d016)","en":"Total RUN time (d016)"},"unit":"h","access":"r","fc":[3],"range":{"min":0,"max":999999},"description":{"ko":"100Eh 상위(MSB)·100Fh 하위(LSB)","en":"100Eh high (MSB), 100Fh low (LSB)"},"ref":"p.4-93","source":0},{"table":"holding-registers","address":4111,"manualAddress":"1010h","type":"u32","order":"ABCD","name":{"ko":"누적 전원 시간(d017)","en":"Power ON time monitor (d017)"},"unit":"h","access":"r","fc":[3],"range":{"min":0,"max":999999},"description":{"ko":"1010h 상위(MSB)·1011h 하위(LSB)","en":"1010h high (MSB), 1011h low (LSB)"},"ref":"p.4-93","source":0},{"table":"holding-registers","address":4457,"manualAddress":"116Ah","type":"u16","name":{"ko":"방열핀 온도(d018)","en":"Fin temperature monitor (d018)"},"unit":"°C","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":200},"ref":"p.4-93","source":0},{"table":"holding-registers","address":4459,"manualAddress":"116Ch","type":"u16","name":{"ko":"직류 전압 모니터(d102)","en":"DC voltage monitor (d102)"},"unit":"V","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":999.9},"ref":"p.4-93","source":0},{"table":"holding-registers","address":4460,"manualAddress":"116Dh","type":"u16","name":{"ko":"전자 서멀 모니터(d104)","en":"Electronic thermal monitor (d104)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":100},"description":{"ko":"100% 에 이르면 과부하 트립(E05)","en":"Overload trip (E05) at 100%"},"ref":"p.4-93","source":0},{"table":"holding-registers","address":4115,"manualAddress":"1014h","type":"u32","order":"ABCD","name":{"ko":"가속 시간 1(F002)","en":"Acceleration time 1 (F002)"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0.01,"max":3000},"description":{"ko":"1014h 상위(MSB)·1015h 하위(LSB). FC10 예(p.4-88~4-89)가 08 10 10 13 00 02 04 00 04 93 E0 7D 53 으로 300000(3000.00 s)을 쓴다. 100.0 s 를 넘으면 소수 둘째 자리는 무시","en":"1014h high (MSB), 1015h low (LSB). The FC10 example (pp.4-88 to 4-89) writes 300000 (3000.00 s) with 08 10 10 13 00 02 04 00 04 93 E0 7D 53. Above 100.0 s the second decimal place is ignored"},"ref":"p.4-94, p.4-88","source":0},{"table":"holding-registers","address":4117,"manualAddress":"1016h","type":"u32","order":"ABCD","name":{"ko":"감속 시간 1(F003)","en":"Deceleration time 1 (F003)"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0.01,"max":3000},"description":{"ko":"1016h 상위(MSB)·1017h 하위(LSB)","en":"1016h high (MSB), 1017h low (LSB)"},"ref":"p.4-94","source":0},{"table":"holding-registers","address":4120,"manualAddress":"1019h","type":"u16","name":{"ko":"주파수 지령 선택(A001)","en":"Frequency reference selection (A001)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"오퍼레이터 볼륨","en":"Digital Operator (volume)"},{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터(F001)","en":"Digital Operator (F001)"},{"value":3,"ko":"Modbus 통신","en":"ModBus communication"},{"value":10,"ko":"주파수 연산 결과","en":"Frequency operation result"}],"description":{"ko":"출하값 00","en":"Default 00"},"ref":"p.4-94, p.4-79","source":0},{"table":"holding-registers","address":4121,"manualAddress":"101Ah","type":"u16","name":{"ko":"운전 지령 선택(A002)","en":"RUN command selection (A002)"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터","en":"Digital Operator"},{"value":3,"ko":"Modbus 통신","en":"ModBus communication"}],"description":{"ko":"출하값 02","en":"Default 02"},"ref":"p.4-94, p.4-79","source":0},{"table":"holding-registers","address":4122,"manualAddress":"101Bh","type":"u16","name":{"ko":"기저 주파수(A003)","en":"Base frequency (A003)"},"unit":"Hz","access":"rw","fc":[3,6,16],"description":{"ko":"30~최고 주파수(A004)","en":"30 to maximum frequency (A004)"},"ref":"p.4-94","source":0},{"table":"holding-registers","address":4123,"manualAddress":"101Ch","type":"u16","name":{"ko":"최고 주파수(A004)","en":"Maximum frequency (A004)"},"unit":"Hz","access":"rw","fc":[3,6,16],"range":{"min":30,"max":400},"ref":"p.4-94","source":0},{"table":"holding-registers","address":4136,"manualAddress":"1029h","type":"u16","name":{"ko":"다단속 0(A020)","en":"Multi-step speed reference 0 (A020)"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":400},"description":{"ko":"0.0 또는 시동 주파수~400.0. FC06 예(p.4-86~4-87)가 08 06 10 28 01 F4 0D 8C 로 500(50.0 Hz)을 쓴다. 다단속 1~15 는 102Bh 부터 2 칸 간격","en":"0.0 or starting frequency to 400.0. The FC06 example (pp.4-86 to 4-87) writes 500 (50.0 Hz) with 08 06 10 28 01 F4 0D 8C. Multi-step speeds 1-15 start at 102Bh, every 2 registers"},"ref":"p.4-95, p.4-86","source":0},{"table":"holding-registers","address":4185,"manualAddress":"105Ah","type":"u16","name":{"ko":"주파수 상한(A061)","en":"Frequency upper limit (A061)"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.0 또는 하한(A062)~최고 주파수(A004)","en":"0.0 or lower limit (A062) to maximum frequency (A004)"},"ref":"p.4-96","source":0},{"table":"holding-registers","address":4186,"manualAddress":"105Bh","type":"u16","name":{"ko":"주파수 하한(A062)","en":"Frequency lower limit (A062)"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"0.0 또는 시동 주파수(b082)~상한(A061)","en":"0.0 or starting frequency (b082) to upper limit (A061)"},"ref":"p.4-96","source":0}],"sources":[{"title":"OMRON SYSDRIVE JX Series Compact Simplified Inverters User's Manual (Cat. No. I558-E1-02)","publisher":"OMRON Corporation","edition":{"ko":"Cat. No. I558-E1-02 (개정 02 = 2008년 4월)","en":"Cat. No. I558-E1-02 (revision 02 = April 2008)"},"url":"https://files.omron.eu/downloads/latest/manual/en/i558_jx_users_manual_en.pdf","pages":{"ko":"4-2 통신 기능 인쇄 p.4-77~4-104(PDF 162~189)","en":"4-2 Communication function printed pp.4-77 to 4-104 (PDF 162-189)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"omron/3g3m1","manufacturer":{"ko":"오므론","en":"OMRON"},"model":"3G3M1","kind":"inverter","title":{"ko":"오므론 M1 시리즈 3G3M1 인버터 표준형 (내장 RS-485 Modbus RTU)","en":"OMRON M1 Series 3G3M1 inverter, standard type (built-in RS-485 Modbus RTU)"},"summary":{"ko":"제어 단자 SP·SN 의 RS-485 Modbus RTU. 코일 0000h~(운전·입력·상태), 지령 S01·S05·S06(5001h~), 주파수 C99(1215h), 파라미터 F·y, 모니터 M(50C1h~)·W(1002h~·5242h~), 알람 0011h~. 데이터 목록 주소 = 프레임 주소","en":"RS-485 Modbus RTU on control terminals SP/SN. Coils from 0000h (run, inputs, status), commands S01/S05/S06 (from 5001h), frequency C99 (1215h), F and y parameters, monitors M (from 50C1h) and W (from 1002h, 5242h), alarms from 0011h. Data list address = frame address"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[2400,4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"order":"ABCD","maxRegisters":100,"addressing":"zero","notes":[{"ko":"주소 체계: 8-9 데이터 목록의 «Modbus 주소» 가 프레임 주소다. 예(8-11~8-21)는 «레지스터 번호 = 주소 + 1» 로 설명한다 — 01 01 00 02 00 0C 9D CF(DI1 코일 0002h~), 01 05 00 00 FF 00 8C 3A(FW 0000h), 01 06 12 16 13 88 60 20(C99 하위 1216h ← 50.00 Hz), 01 0F 00 02 00 0C 02 17 00 EB A2, 01 10 11 02 00 02 04 00 00 03 E8 B2 98(F07 1102h·1103h ← 10.00 s), 01 17 52 44 00 02 12 15 00 02 04 00 00 13 88 E8 67(W03 읽기·C99 쓰기), 엔터 08 06 08 FF 00 01 7A C3. 응답 01 01 02 08 05 7E 3F, 01 03 14 …F9 14, 01 0F 00 02 00 0C F4 0E, 01 10 11 02 00 02 E5 34, 01 17 04 00 00 13 88 F4 71 까지 CRC 가 계산값과 같다.","en":"Addressing: the «Modbus address» in the 8-9 data lists is the frame address. The examples (8-11 to 8-21) describe it as «register number = address + 1»: 01 01 00 02 00 0C 9D CF (coils from DI1 0002h), 01 05 00 00 FF 00 8C 3A (FW 0000h), 01 06 12 16 13 88 60 20 (C99 low word 1216h ← 50.00 Hz), 01 0F 00 02 00 0C 02 17 00 EB A2, 01 10 11 02 00 02 04 00 00 03 E8 B2 98 (F07 1102h/1103h ← 10.00 s), 01 17 52 44 00 02 12 15 00 02 04 00 00 13 88 E8 67 (read W03, write C99), Enter 08 06 08 FF 00 01 7A C3. The replies 01 01 02 08 05 7E 3F, 01 03 14 … F9 14, 01 0F 00 02 00 0C F4 0E, 01 10 11 02 00 02 E5 34 and 01 17 04 00 00 13 88 F4 71 all have CRCs matching calculation."},{"ko":"매뉴얼 FC03 예(8-12)의 오타: 시작 주소를 0011h(01 03 00 11 00 0A)로 적었지만 CRC C4 08 은 0010h 로 계산한 값이다(0011h 면 95 C8). 응답 내용(알람 코드·상태·12.34 Hz·3.00 A·284.0 V)은 데이터 목록의 0011h~ 배치와 맞아 0011h 를 따랐다.","en":"Typo in the manual FC03 example (8-12): the start address is written 0011h (01 03 00 11 00 0A), but its CRC C4 08 is calculated for 0010h (0011h gives 95 C8). The reply contents (alarm code, status, 12.34 Hz, 3.00 A, 284.0 V) match the data list layout from 0011h, so 0011h is used."},{"ko":"출하값(8-5~8-6): 국번 y11 = 1(1~255), 속도 y14 = 2(9600 bps), 패리티 y16 = 3(없음·정지 1), 데이터 8비트. 통신으로 운전하려면 F02(또는 E102) = 4, 주파수는 F01(또는 C30) = 14. 함수 코드 01·03·05·06·08·0F·10·17h, 한 번에 03h 100개·10h 100개·17h 각 16개(8-8). 종단 저항 110 Ω 내장(SW6, 8-4).","en":"Defaults (8-5 to 8-6): station y11 = 1 (1-255), baud y14 = 2 (9600 bps), parity y16 = 3 (none, 1 stop), 8 data bits. To run over communication set F02 (or E102) = 4; for frequency F01 (or C30) = 14. Function codes 01, 03, 05, 06, 08, 0F, 10 and 17h; up to 100 registers for 03h and 10h, 16 each for 17h (8-8). Built-in 110 Ω terminator (SW6, 8-4)."}]},"registers":[{"table":"coils","address":0,"manualAddress":"0000 hex","type":"bit","name":{"ko":"FW (정회전 운전)","en":"FW (forward run)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. F02 = 4(RS-485) 일 때. 매뉴얼 예 01 05 00 00 FF 00 8C 3A","en":"1 = ON. With F02 = 4 (RS-485). Manual example 01 05 00 00 FF 00 8C 3A"},"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":1,"manualAddress":"0001 hex","type":"bit","name":{"ko":"RV (역회전 운전)","en":"RV (reverse run)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":2,"manualAddress":"0002 hex","type":"bit","name":{"ko":"DI1 (다기능 입력 1)","en":"DI1 (multifunction input 1)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":3,"manualAddress":"0003 hex","type":"bit","name":{"ko":"DI2 (다기능 입력 2)","en":"DI2 (multifunction input 2)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":4,"manualAddress":"0004 hex","type":"bit","name":{"ko":"DI3 (다기능 입력 3)","en":"DI3 (multifunction input 3)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":5,"manualAddress":"0005 hex","type":"bit","name":{"ko":"DI4 (다기능 입력 4)","en":"DI4 (multifunction input 4)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":6,"manualAddress":"0006 hex","type":"bit","name":{"ko":"DI5 (다기능 입력 5)","en":"DI5 (multifunction input 5)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":13,"manualAddress":"000D hex","type":"bit","name":{"ko":"DI6 (다기능 입력 6)","en":"DI6 (multifunction input 6)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":14,"manualAddress":"000E hex","type":"bit","name":{"ko":"DI7 (다기능 입력 7)","en":"DI7 (multifunction input 7)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":15,"manualAddress":"000F hex","type":"bit","name":{"ko":"RS (리셋)","en":"RS (reset)"},"access":"rw","fc":[1,5,15],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":16,"manualAddress":"0010 hex","type":"bit","name":{"ko":"FWR (정회전 중)","en":"FWR (during forward rotation)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":17,"manualAddress":"0011 hex","type":"bit","name":{"ko":"RVR (역회전 중)","en":"RVR (during reverse rotation)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":19,"manualAddress":"0013 hex","type":"bit","name":{"ko":"INT (인버터 출력 차단)","en":"INT (inverter shut down)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":21,"manualAddress":"0015 hex","type":"bit","name":{"ko":"NUV (DC 링크 전압 확립)","en":"NUV (DC link voltage established)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":25,"manualAddress":"0019 hex","type":"bit","name":{"ko":"ACC (가속 중)","en":"ACC (during acceleration)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":26,"manualAddress":"001A hex","type":"bit","name":{"ko":"DEC (감속 중)","en":"DEC (during deceleration)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":27,"manualAddress":"001B hex","type":"bit","name":{"ko":"ALM (알람 릴레이)","en":"ALM (alarm relay)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":28,"manualAddress":"001C hex","type":"bit","name":{"ko":"RL (통신 유효)","en":"RL (communications effective)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":32,"manualAddress":"0020 hex","type":"bit","name":{"ko":"FA1 (정속 도달)","en":"FA1 (constant speed arrival)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":34,"manualAddress":"0022 hex","type":"bit","name":{"ko":"IRDY (운전 준비 완료)","en":"IRDY (operation ready)"},"access":"r","fc":[1],"ref":"8-34~8-35 (PDF 684-685)","source":0},{"table":"coils","address":64,"manualAddress":"0040 hex","type":"bit","name":{"ko":"DO1 (다기능 출력 1)","en":"DO1 (multifunction output 1)"},"access":"r","fc":[1],"ref":"8-35~8-36 (PDF 685-686)","source":0},{"table":"coils","address":65,"manualAddress":"0041 hex","type":"bit","name":{"ko":"DO2 (다기능 출력 2)","en":"DO2 (multifunction output 2)"},"access":"r","fc":[1],"ref":"8-35~8-36 (PDF 685-686)","source":0},{"table":"coils","address":72,"manualAddress":"0048 hex","type":"bit","name":{"ko":"RO (다기능 릴레이 출력)","en":"RO (multifunction relay output)"},"access":"r","fc":[1],"ref":"8-35~8-36 (PDF 685-686)","source":0},{"table":"holding-registers","address":20481,"manualAddress":"5001h","type":"s16","name":{"ko":"S01 주파수 지령 (±20000 = 최고 주파수)","en":"S01 frequency reference (±20000 = max frequency)"},"access":"rw","fc":[3,6,16],"range":{"min":-32768,"max":32767},"description":{"ko":"데이터 형식 [29]: ±20000 이 최고 출력 주파수(F03) ±100 %. F01 = 14(RS-485) 일 때 쓰인다","en":"Data format [29]: ±20000 is ±100 % of the maximum output frequency (F03). Used with F01 = 14 (RS-485)"},"ref":"8-74 (PDF 724), 8-41 (PDF 691), 8-87 (PDF 737)","source":0},{"table":"holding-registers","address":20485,"manualAddress":"5005h","type":"u32","order":"ABCD","name":{"ko":"S05 주파수 지령 (0.01 Hz)","en":"S05 frequency reference (0.01 Hz)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"5005h(상위)·5006h(하위) 2워드","en":"Two words, 5005h (high) and 5006h (low)"},"ref":"8-74 (PDF 724), 8-87 (PDF 737)","source":0},{"table":"holding-registers","address":20487,"manualAddress":"5007h","type":"u16","name":{"ko":"S06 운전 명령","en":"S06 operation command"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"FWD 정회전","en":"FWD forward"},{"bit":1,"ko":"REV 역회전","en":"REV reverse"},{"bit":2,"ko":"DI1","en":"DI1"},{"bit":3,"ko":"DI2","en":"DI2"},{"bit":4,"ko":"DI3","en":"DI3"},{"bit":5,"ko":"DI4","en":"DI4"},{"bit":6,"ko":"DI5","en":"DI5"},{"bit":13,"ko":"DI6","en":"DI6"},{"bit":14,"ko":"DI7","en":"DI7"},{"bit":15,"ko":"RST 알람 리셋","en":"RST alarm reset"}],"description":{"ko":"데이터 형식 [14]. 예: 정회전 + DI1 = 0005h. F02 = 4(RS-485) 일 때","en":"Data format [14]. Example: FWD + DI1 = 0005h. With F02 = 4 (RS-485)"},"ref":"8-74 (PDF 724), 8-39 (PDF 689), 8-87 (PDF 737)","source":0},{"table":"holding-registers","address":4629,"manualAddress":"1215h","type":"u32","order":"ABCD","name":{"ko":"C99 주파수 지령 / 다단 주파수 0","en":"C99 frequency reference / multi-step frequency 0"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"1215h(상위)·1216h(하위). 매뉴얼 FC06 예는 하위 워드 1216h 에 1388h(50.00 Hz)를 쓴다: 01 06 12 16 13 88 60 20","en":"1215h (high), 1216h (low). The manual FC06 example writes 1388h (50.00 Hz) to the low word 1216h: 01 06 12 16 13 88 60 20"},"ref":"8-56 (PDF 706), 8-14 (PDF 664)~8-15","source":0},{"table":"holding-registers","address":2303,"manualAddress":"08FFh","type":"u16","name":{"ko":"엔터 명령 (EEPROM 저장)","en":"Enter command (save to EEPROM)"},"access":"w","fc":[6],"values":[{"value":1,"ko":"설정값을 EEPROM 에 저장(자동으로 0 으로 돌아감)","en":"Store set values in EEPROM (returns to 0)"}],"description":{"ko":"매뉴얼은 레지스터 번호 0900h 로 적고 프레임 주소는 08FFh(번호 − 1). 예: 08 06 08 FF 00 01 7A C3. 06·10·17h 로 쓴 값은 EEPROM 에 저장되지 않아 전원을 끄면 돌아간다","en":"The manual gives register number 0900h; the frame address is 08FFh (number − 1). Example: 08 06 08 FF 00 01 7A C3. Values written with 06/10/17h are not stored in EEPROM and revert at power-off"},"ref":"8-21 (PDF 671)","source":0},{"table":"holding-registers","address":12289,"manualAddress":"3001h","type":"u16","name":{"ko":"F01 1차 주파수 지령 선택","en":"F01 1st frequency reference selection"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":15},"values":[{"value":14,"ko":"RS-485 통신","en":"RS-485 communication"}],"description":{"ko":"출하값 0. 통신으로 주파수를 주려면 14","en":"Default 0. Set 14 to give the frequency over communication"},"ref":"8-47 (PDF 697), 8-5 (PDF 655)","source":0},{"table":"holding-registers","address":4609,"manualAddress":"1201h","type":"u16","name":{"ko":"F02 1차 운전 명령 선택","en":"F02 1st RUN command selection"},"access":"rw","fc":[3,6,16],"values":[{"value":4,"ko":"RS-485 통신","en":"RS-485 communication"}],"description":{"ko":"출하값 2. 통신으로 운전하려면 4","en":"Default 2. Set 4 to run over communication"},"ref":"8-47 (PDF 697), 8-5 (PDF 655)","source":0},{"table":"holding-registers","address":12291,"manualAddress":"3003h","type":"u16","name":{"ko":"F03 1차 최고 출력 주파수","en":"F03 1st maximum output frequency"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":5,"max":590},"description":{"ko":"데이터 형식 [3](0.1). 예: 70.0 Hz = 02BCh","en":"Data format [3] (0.1). Example: 70.0 Hz = 02BCh"},"ref":"8-47 (PDF 697), 8-37 (PDF 687)","source":0},{"table":"holding-registers","address":4354,"manualAddress":"1102h","type":"u32","order":"ABCD","name":{"ko":"F07 1차 가속 시간 1","en":"F07 1st acceleration time 1"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"1102h·1103h 2워드(0.01 s). 예: 10.00 s = 0000 03E8h — 01 10 11 02 00 02 04 00 00 03 E8 B2 98. 1워드 접근은 부동소수 형식 [12]","en":"Two words 1102h/1103h (0.01 s). Example: 10.00 s = 0000 03E8h — 01 10 11 02 00 02 04 00 00 03 E8 B2 98. Single-word access uses floating format [12]"},"ref":"8-47 (PDF 697), 8-18 (PDF 668)","source":0},{"table":"holding-registers","address":4356,"manualAddress":"1104h","type":"u32","order":"ABCD","name":{"ko":"F08 1차 감속 시간 1","en":"F08 1st deceleration time 1"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"1104h·1105h 2워드(0.01 s)","en":"Two words 1104h/1105h (0.01 s)"},"ref":"8-47 (PDF 697)","source":0},{"table":"holding-registers","address":16907,"manualAddress":"420Bh","type":"u16","name":{"ko":"y11 RS-485 국번","en":"y11 RS-485 station number"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":255},"description":{"ko":"출하값 1","en":"Default 1"},"ref":"8-74 (PDF 724), 8-6 (PDF 656)","source":0},{"table":"holding-registers","address":16908,"manualAddress":"420Ch","type":"u16","name":{"ko":"y12 통신 오류 시 동작","en":"y12 operation on communication error"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"즉시 트립(ErP)","en":"Trip immediately (ErP)"},{"value":1,"ko":"y13 시간 운전 후 트립","en":"Trip after running for timer y13"},{"value":2,"ko":"y13 시간 재시도, 실패하면 트립","en":"Retry for timer y13, trip if not restored"},{"value":3,"ko":"계속 운전","en":"Continue to run"},{"value":11,"ko":"감속 정지 후 트립","en":"Trip after deceleration stop"},{"value":13,"ko":"프리런 정지(트립 없음)","en":"Free-run stop (no trip)"},{"value":14,"ko":"감속 정지(트립 없음)","en":"Deceleration stop (no trip)"}],"description":{"ko":"출하값 0. y18(통신 타임아웃) 시간 동안 통신이 없으면 동작","en":"Default 0. Acts when communication stops for longer than y18 (timeout)"},"ref":"8-74 (PDF 724), 8-5 (PDF 655)~8-6","source":0},{"table":"holding-registers","address":16910,"manualAddress":"420Eh","type":"u16","name":{"ko":"y14 RS-485 통신 속도","en":"y14 RS-485 baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"2400 bps","en":"2400 bps"},{"value":1,"ko":"4800 bps","en":"4800 bps"},{"value":2,"ko":"9600 bps","en":"9600 bps"},{"value":3,"ko":"19200 bps","en":"19200 bps"},{"value":4,"ko":"38400 bps","en":"38400 bps"},{"value":5,"ko":"57600 bps","en":"57600 bps"},{"value":6,"ko":"76800 bps","en":"76800 bps"},{"value":7,"ko":"115200 bps","en":"115200 bps"}],"description":{"ko":"출하값 2(9600 bps)","en":"Default 2 (9600 bps)"},"ref":"8-74 (PDF 724), 8-6 (PDF 656)","source":0},{"table":"holding-registers","address":16912,"manualAddress":"4210h","type":"u16","name":{"ko":"y16 RS-485 패리티","en":"y16 RS-485 parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음(정지 2비트)","en":"None (2 stop bits)"},{"value":1,"ko":"짝수(정지 1비트)","en":"Even (1 stop bit)"},{"value":2,"ko":"홀수(정지 1비트)","en":"Odd (1 stop bit)"},{"value":3,"ko":"없음(정지 1비트)","en":"None (1 stop bit)"}],"description":{"ko":"출하값 3","en":"Default 3"},"ref":"8-74 (PDF 724), 8-6 (PDF 656)","source":0},{"table":"holding-registers","address":20673,"manualAddress":"50C1h","type":"s16","name":{"ko":"M01 최종 주파수 지령 (±20000 = 최고 주파수)","en":"M01 final frequency reference (±20000 = max frequency)"},"access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-2 (PDF 168)","source":0},{"table":"holding-registers","address":20677,"manualAddress":"50C5h","type":"u32","order":"ABCD","name":{"ko":"M05 최종 주파수 지령","en":"M05 final frequency reference"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"50C5h·50C6h","en":"50C5h/50C6h"},"ref":"8-75 (PDF 725), 4-2 (PDF 168)","source":0},{"table":"holding-registers","address":20680,"manualAddress":"50C8h","type":"s16","name":{"ko":"M07 토크 값","en":"M07 torque value"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-3 (PDF 169)","source":0},{"table":"holding-registers","address":20682,"manualAddress":"50CAh","type":"u32","order":"ABCD","name":{"ko":"M09 출력 주파수 (슬립 보상 없음)","en":"M09 output frequency without slip compensation"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"50CAh·50CBh","en":"50CAh/50CBh"},"ref":"8-75 (PDF 725), 4-3 (PDF 169)","source":0},{"table":"holding-registers","address":20684,"manualAddress":"50CCh","type":"u16","name":{"ko":"M10 입력 전력","en":"M10 input power"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-3 (PDF 169)","source":0},{"table":"holding-registers","address":20685,"manualAddress":"50CDh","type":"u16","name":{"ko":"M11 출력 전류 (%)","en":"M11 output current (%)"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-3 (PDF 169)","source":0},{"table":"holding-registers","address":20686,"manualAddress":"50CEh","type":"u16","name":{"ko":"M12 출력 전압","en":"M12 output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-3 (PDF 169)","source":0},{"table":"holding-registers","address":20687,"manualAddress":"50CFh","type":"u16","name":{"ko":"M13 최종 운전 명령","en":"M13 final operation command"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전","en":"FWD forward"},{"bit":1,"ko":"REV 역회전","en":"REV reverse"},{"bit":2,"ko":"DI1","en":"DI1"},{"bit":3,"ko":"DI2","en":"DI2"},{"bit":4,"ko":"DI3","en":"DI3"},{"bit":5,"ko":"DI4","en":"DI4"},{"bit":6,"ko":"DI5","en":"DI5"},{"bit":13,"ko":"DI6","en":"DI6"},{"bit":14,"ko":"DI7","en":"DI7"},{"bit":15,"ko":"RST 알람 리셋","en":"RST alarm reset"}],"ref":"8-75 (PDF 725), 4-3 (PDF 169)","source":0},{"table":"holding-registers","address":20688,"manualAddress":"50D0h","type":"u16","name":{"ko":"M14 운전 상태 1","en":"M14 operation status 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD during forward run"},{"bit":1,"ko":"REV 역회전 중","en":"REV during reverse run"},{"bit":2,"ko":"EXT 직류 제동·예비 여자 중","en":"EXT DC braking / pre-exciting"},{"bit":3,"ko":"INT 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중","en":"BRK braking"},{"bit":5,"ko":"NUV DC 전압 확립(0 = 부족 전압)","en":"NUV DC voltage established (0 = undervoltage)"},{"bit":6,"ko":"TL 토크 제한 중","en":"TL torque limiting"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 알람 릴레이","en":"ALM alarm relay"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 파라미터 쓰는 중","en":"BUSY writing parameter data"}],"description":{"ko":"데이터 형식 [16]. 예: 정회전·가속 중 = 0201h(FC03 응답 예의 두 번째 워드)","en":"Data format [16]. Example: forward + accelerating = 0201h (second word of the FC03 reply example)"},"ref":"8-75 (PDF 725), 8-39 (PDF 689)~8-40","source":0},{"table":"holding-registers","address":20689,"manualAddress":"50D1h","type":"u16","name":{"ko":"M15 출력 단자","en":"M15 output terminals"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"DO1","en":"DO1"},{"bit":1,"ko":"DO2","en":"DO2"},{"bit":8,"ko":"RO 릴레이","en":"RO relay"}],"ref":"8-75 (PDF 725), 4-4 (PDF 170)","source":0},{"table":"holding-registers","address":17,"manualAddress":"0011h","type":"u16","name":{"ko":"M16 최근 알람","en":"M16 latest alarm"},"access":"r","fc":[3],"values":[{"value":0,"ko":"알람 없음","en":"No alarm"},{"value":1,"ko":"OC1 과전류(가속 중)","en":"OC1 overcurrent (accel)"},{"value":2,"ko":"OC2 과전류(감속 중)","en":"OC2 overcurrent (decel)"},{"value":3,"ko":"OC3 과전류(정속 중)","en":"OC3 overcurrent (constant speed)"},{"value":6,"ko":"OU1 과전압(가속 중)","en":"OU1 overvoltage (accel)"},{"value":7,"ko":"OU2 과전압(감속 중)","en":"OU2 overvoltage (decel)"},{"value":8,"ko":"OU3 과전압(정속 중)","en":"OU3 overvoltage (constant speed)"},{"value":10,"ko":"LU 부족 전압","en":"LU undervoltage"},{"value":11,"ko":"Lin 입력 결상","en":"Lin input phase loss"},{"value":17,"ko":"OH1 방열판 과열","en":"OH1 heat sink overheat"},{"value":18,"ko":"OH2 외부 트립","en":"OH2 external trip"},{"value":23,"ko":"OL1 모터 1 과부하","en":"OL1 motor 1 overload"},{"value":25,"ko":"OLU 인버터 과부하","en":"OLU inverter overload"},{"value":46,"ko":"OPL 출력 결상","en":"OPL output phase loss"},{"value":53,"ko":"ErP RS-485 통신 오류","en":"ErP RS-485 communication error"}],"description":{"ko":"데이터 형식 [10] 알람 코드(일부만 적음 — 전체는 8-37~8-38). FC03 예가 0011h 부터 10워드를 읽어 0001h(OC1)를 받는다","en":"Data format [10] alarm code (partial list; full list on 8-37 to 8-38). The FC03 example reads 10 words from 0011h and gets 0001h (OC1)"},"ref":"8-75 (PDF 725), 8-37 (PDF 687)~8-38, 8-12 (PDF 662)~8-13","source":0},{"table":"holding-registers","address":27,"manualAddress":"001Bh","type":"u16","name":{"ko":"M17 직전 알람","en":"M17 last alarm"},"access":"r","fc":[3],"values":[{"value":0,"ko":"알람 없음","en":"No alarm"},{"value":1,"ko":"OC1 과전류(가속 중)","en":"OC1 overcurrent (accel)"},{"value":2,"ko":"OC2 과전류(감속 중)","en":"OC2 overcurrent (decel)"},{"value":3,"ko":"OC3 과전류(정속 중)","en":"OC3 overcurrent (constant speed)"},{"value":6,"ko":"OU1 과전압(가속 중)","en":"OU1 overvoltage (accel)"},{"value":7,"ko":"OU2 과전압(감속 중)","en":"OU2 overvoltage (decel)"},{"value":8,"ko":"OU3 과전압(정속 중)","en":"OU3 overvoltage (constant speed)"},{"value":10,"ko":"LU 부족 전압","en":"LU undervoltage"},{"value":11,"ko":"Lin 입력 결상","en":"Lin input phase loss"},{"value":17,"ko":"OH1 방열판 과열","en":"OH1 heat sink overheat"},{"value":18,"ko":"OH2 외부 트립","en":"OH2 external trip"},{"value":23,"ko":"OL1 모터 1 과부하","en":"OL1 motor 1 overload"},{"value":25,"ko":"OLU 인버터 과부하","en":"OLU inverter overload"},{"value":46,"ko":"OPL 출력 결상","en":"OPL output phase loss"},{"value":53,"ko":"ErP RS-485 통신 오류","en":"ErP RS-485 communication error"}],"ref":"8-75 (PDF 725)","source":0},{"table":"holding-registers","address":37,"manualAddress":"0025h","type":"u16","name":{"ko":"M18 2회 전 알람","en":"M18 second last alarm"},"access":"r","fc":[3],"values":[{"value":0,"ko":"알람 없음","en":"No alarm"},{"value":1,"ko":"OC1 과전류(가속 중)","en":"OC1 overcurrent (accel)"},{"value":2,"ko":"OC2 과전류(감속 중)","en":"OC2 overcurrent (decel)"},{"value":3,"ko":"OC3 과전류(정속 중)","en":"OC3 overcurrent (constant speed)"},{"value":6,"ko":"OU1 과전압(가속 중)","en":"OU1 overvoltage (accel)"},{"value":7,"ko":"OU2 과전압(감속 중)","en":"OU2 overvoltage (decel)"},{"value":8,"ko":"OU3 과전압(정속 중)","en":"OU3 overvoltage (constant speed)"},{"value":10,"ko":"LU 부족 전압","en":"LU undervoltage"},{"value":11,"ko":"Lin 입력 결상","en":"Lin input phase loss"},{"value":17,"ko":"OH1 방열판 과열","en":"OH1 heat sink overheat"},{"value":18,"ko":"OH2 외부 트립","en":"OH2 external trip"},{"value":23,"ko":"OL1 모터 1 과부하","en":"OL1 motor 1 overload"},{"value":25,"ko":"OLU 인버터 과부하","en":"OLU inverter overload"},{"value":46,"ko":"OPL 출력 결상","en":"OPL output phase loss"},{"value":53,"ko":"ErP RS-485 통신 오류","en":"ErP RS-485 communication error"}],"ref":"8-75 (PDF 725)","source":0},{"table":"holding-registers","address":47,"manualAddress":"002Fh","type":"u16","name":{"ko":"M19 3회 전 알람","en":"M19 third last alarm"},"access":"r","fc":[3],"values":[{"value":0,"ko":"알람 없음","en":"No alarm"},{"value":1,"ko":"OC1 과전류(가속 중)","en":"OC1 overcurrent (accel)"},{"value":2,"ko":"OC2 과전류(감속 중)","en":"OC2 overcurrent (decel)"},{"value":3,"ko":"OC3 과전류(정속 중)","en":"OC3 overcurrent (constant speed)"},{"value":6,"ko":"OU1 과전압(가속 중)","en":"OU1 overvoltage (accel)"},{"value":7,"ko":"OU2 과전압(감속 중)","en":"OU2 overvoltage (decel)"},{"value":8,"ko":"OU3 과전압(정속 중)","en":"OU3 overvoltage (constant speed)"},{"value":10,"ko":"LU 부족 전압","en":"LU undervoltage"},{"value":11,"ko":"Lin 입력 결상","en":"Lin input phase loss"},{"value":17,"ko":"OH1 방열판 과열","en":"OH1 heat sink overheat"},{"value":18,"ko":"OH2 외부 트립","en":"OH2 external trip"},{"value":23,"ko":"OL1 모터 1 과부하","en":"OL1 motor 1 overload"},{"value":25,"ko":"OLU 인버터 과부하","en":"OLU inverter overload"},{"value":46,"ko":"OPL 출력 결상","en":"OPL output phase loss"},{"value":53,"ko":"ErP RS-485 통신 오류","en":"ErP RS-485 communication error"}],"ref":"8-75 (PDF 725)","source":0},{"table":"holding-registers","address":20694,"manualAddress":"50D6h","type":"u32","order":"ABCD","name":{"ko":"M20 누적 운전 시간","en":"M20 cumulative operation time"},"unit":"h","access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-12 (PDF 178)","source":0},{"table":"holding-registers","address":20696,"manualAddress":"50D8h","type":"u16","name":{"ko":"M21 주회로 DC 전압","en":"M21 main circuit DC voltage"},"unit":"V","access":"r","fc":[3],"ref":"8-75 (PDF 725), 4-12 (PDF 178)","source":0},{"table":"holding-registers","address":20738,"manualAddress":"5102h","type":"s16","name":{"ko":"M61 인버터 내부 공기 온도","en":"M61 inverter internal air temperature"},"unit":"℃","scale":0.1,"access":"r","fc":[3],"ref":"8-77 (PDF 727), 4-17 (PDF 183)","source":0},{"table":"holding-registers","address":4120,"manualAddress":"1018h","type":"s16","name":{"ko":"M62 방열판 온도","en":"M62 fin temperature"},"unit":"℃","scale":0.1,"access":"r","fc":[3],"ref":"8-77 (PDF 727), 4-17 (PDF 183)","source":0},{"table":"holding-registers","address":20746,"manualAddress":"510Ah","type":"u16","name":{"ko":"M69 인버터 정격 전류","en":"M69 inverter rated current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"8-77 (PDF 727), 4-18 (PDF 184)","source":0},{"table":"holding-registers","address":4099,"manualAddress":"1003h","type":"u16","name":{"ko":"W01 운전 상태 1","en":"W01 running status 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"FWD 정회전 중","en":"FWD during forward run"},{"bit":1,"ko":"REV 역회전 중","en":"REV during reverse run"},{"bit":2,"ko":"EXT 직류 제동·예비 여자 중","en":"EXT DC braking / pre-exciting"},{"bit":3,"ko":"INT 출력 차단","en":"INT inverter shut down"},{"bit":4,"ko":"BRK 제동 중","en":"BRK braking"},{"bit":5,"ko":"NUV DC 전압 확립(0 = 부족 전압)","en":"NUV DC voltage established (0 = undervoltage)"},{"bit":6,"ko":"TL 토크 제한 중","en":"TL torque limiting"},{"bit":7,"ko":"VL 전압 제한 중","en":"VL voltage limiting"},{"bit":8,"ko":"IL 전류 제한 중","en":"IL current limiting"},{"bit":9,"ko":"ACC 가속 중","en":"ACC accelerating"},{"bit":10,"ko":"DEC 감속 중","en":"DEC decelerating"},{"bit":11,"ko":"ALM 알람 릴레이","en":"ALM alarm relay"},{"bit":12,"ko":"RL 통신 유효","en":"RL communications effective"},{"bit":15,"ko":"BUSY 파라미터 쓰는 중","en":"BUSY writing parameter data"}],"ref":"8-77 (PDF 727), 4-30 (PDF 196)","source":0},{"table":"holding-registers","address":21058,"manualAddress":"5242h","type":"u32","order":"ABCD","name":{"ko":"W02 주파수 지령 모니터","en":"W02 frequency reference monitor"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"5242h·5243h","en":"5242h/5243h"},"ref":"8-77 (PDF 727), 4-30 (PDF 196)","source":0},{"table":"holding-registers","address":21060,"manualAddress":"5244h","type":"u32","order":"ABCD","name":{"ko":"W03 출력 주파수 (슬립 보상 전)","en":"W03 output frequency before slip compensation"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"5244h·5245h. FC17 예가 5244h 부터 2워드를 읽어 0000 1388h(50.00 Hz)를 받는다","en":"5244h/5245h. The FC17 example reads 2 words from 5244h and gets 0000 1388h (50.00 Hz)"},"ref":"8-78 (PDF 728), 8-19 (PDF 669)","source":0},{"table":"holding-registers","address":21062,"manualAddress":"5246h","type":"u32","order":"ABCD","name":{"ko":"W04 출력 주파수 (슬립 보상 후)","en":"W04 output frequency after slip compensation"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"ref":"8-78 (PDF 728), 4-30 (PDF 196)","source":0},{"table":"holding-registers","address":4098,"manualAddress":"1002h","type":"u16","name":{"ko":"W05 출력 전류","en":"W05 output current"},"unit":"A","scale":0.01,"access":"r","fc":[3],"ref":"8-78 (PDF 728), 4-30 (PDF 196)","source":0},{"table":"holding-registers","address":4112,"manualAddress":"1010h","type":"u16","name":{"ko":"W06 출력 전압","en":"W06 output voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"8-78 (PDF 728), 4-30 (PDF 196)","source":0},{"table":"holding-registers","address":4111,"manualAddress":"100Fh","type":"s16","name":{"ko":"W07 출력 토크","en":"W07 output torque"},"unit":"%","access":"r","fc":[3],"range":{"min":-999,"max":999},"ref":"8-78 (PDF 728), 4-31 (PDF 197)","source":0},{"table":"holding-registers","address":4102,"manualAddress":"1006h","type":"u16","name":{"ko":"W40 입력 단자","en":"W40 input terminals"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"DI6","en":"DI6"},{"bit":1,"ko":"DI7","en":"DI7"},{"bit":2,"ko":"DI1","en":"DI1"},{"bit":3,"ko":"DI2","en":"DI2"},{"bit":4,"ko":"DI3","en":"DI3"},{"bit":5,"ko":"DI4","en":"DI4"},{"bit":6,"ko":"DI5","en":"DI5"},{"bit":11,"ko":"EN1","en":"EN1"},{"bit":12,"ko":"EN2","en":"EN2"}],"description":{"ko":"데이터 형식 [43]. 예: 0061h = DI4·DI5·DI6 ON","en":"Data format [43]. Example: 0061h = DI4, DI5, DI6 ON"},"ref":"8-78 (PDF 728), 8-43 (PDF 693)","source":0},{"table":"holding-registers","address":4103,"manualAddress":"1007h","type":"u16","name":{"ko":"W41 출력 신호","en":"W41 output signals"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"DO1","en":"DO1"},{"bit":1,"ko":"DO2","en":"DO2"},{"bit":8,"ko":"RO 릴레이","en":"RO relay"}],"ref":"8-78 (PDF 728)","source":0},{"table":"holding-registers","address":4116,"manualAddress":"1014h","type":"u32","order":"ABCD","name":{"ko":"W179 총 운전 시간","en":"W179 total RUN time"},"unit":"h","access":"r","fc":[3],"ref":"8-81 (PDF 731), 4-40 (PDF 206)","source":0}],"notes":[{"ko":"2워드 값은 상위 워드가 낮은 주소(빅 엔디언). 하위 워드만 쓰면 하위만 바뀌고, 상위 워드만 쓰면 예외 02(8-25). H396(엔디언 선택)을 바꾸면 순서가 바뀐다.","en":"Two-word values put the high word at the lower address (big endian). Writing only the low word changes only the low word; writing only the high word gives exception 02 (8-25). Changing H396 (endian selection) changes the order."},{"ko":"통신으로 쓴 값은 EEPROM 에 저장되지 않는다(y97 출하값 1). 남기려면 엔터 명령(0900h 번호 = 08FFh)에 1 을 쓴다(8-21).","en":"Values written over communication are not saved to EEPROM (y97 default 1). To keep them, write 1 to the Enter command (register number 0900h = address 08FFh) (8-21)."},{"ko":"뺀 것: 8-9 표에서 이름·형식 칸이 줄마다 어긋난 쪽(8-48·8-56·8-74·8-78·8-80)의 항목 중 예나 4장 목록으로 맞출 수 없는 것, W71(데이터 목록은 DC 전압인데 4장 모니터 목록은 «사용 안 함»), y18·y19(형식 칸을 확정 못 함). 쪽 번호는 인쇄 쪽(8장 PDF = 650 + 쪽, 4장 PDF = 166 + 쪽).","en":"Left out: items on pages where the name and format columns are shifted (8-48, 8-56, 8-74, 8-78, 8-80) that could not be matched by an example or the chapter 4 list; W71 (DC voltage in the data list but «do not use» in the chapter 4 monitor list); y18 and y19 (format column not certain). Page numbers are printed pages (chapter 8 PDF = 650 + page, chapter 4 PDF = 166 + page)."}],"sources":[{"title":"M1 Series Standard Type User's Manual","publisher":"OMRON Corporation","edition":{"ko":"Cat. No. I669-E1-03","en":"Cat. No. I669-E1-03"},"url":"https://files.omron.eu/downloads/latest/manual/en/i669b_m1_series_standard_type_v1.0_users_manual_en.pdf","pages":{"ko":"모니터 목록 4-2~4-40 (PDF 168-206), 통신 8-3~8-22 (PDF 653-672), 데이터 목록 8-34~8-86 (PDF 684-736), 통신 지령 8-87 (PDF 737)","en":"monitor lists 4-2 to 4-40 (PDF 168-206), communications 8-3 to 8-22 (PDF 653-672), data lists 8-34 to 8-86 (PDF 684-736), commands via communication 8-87 (PDF 737)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"omron/3g3rx","manufacturer":{"ko":"오므론","en":"OMRON"},"model":"3G3RX","kind":"inverter","title":{"ko":"오므론 3G3RX 인버터 (내장 RS-485 Modbus RTU)","en":"OMRON 3G3RX inverter (built-in RS-485 Modbus RTU)"},"summary":{"ko":"내장 RS-485 Modbus RTU(C079 = 01). 코일 0001h~(운전·상태), 보유 레지스터 0001h~(지령·트립 이력), 1001h~(d 모니터), 1103h~(F·A·C 파라미터). 매뉴얼 번호 − 1 = 프레임 주소. 한 번에 레지스터 4개까지","en":"Built-in RS-485 Modbus RTU (C079 = 01). Coils from 0001h (run, status), holding registers from 0001h (commands, trip history), 1001h (d monitors), 1103h (F/A/C parameters). Manual number - 1 = frame address. Up to 4 registers per message"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[2400,4800,9600,19200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"maxRegisters":4,"order":"ABCD","addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼의 코일·레지스터 번호는 1 기준이고 예마다 «시작 번호는 1 줄여서 보낸다» 주석이 있다 (p.4-168~4-173). 예: 코일 읽기(p.4-168) 08 01 00 06 00 06 5C 90 → 코일 0007h~(다기능 입력 1~), 코일 쓰기(p.4-170) 0A 05 00 00 FF 00 8D 41 → 코일 0001h(운전 지령), 레지스터 읽기(p.4-169) 05 03 00 11 00 02 95 8A → 0012h(트립 요인)·0013h, FC06(p.4-171) 05 06 12 02 00 32 AD 23 → 1203h(A003)에 50, FC10(p.4-173) 01 10 11 02 00 02 04 00 04 93 E0 9E 9F → 1103h·1104h(F002)에 300000. 이 프레임들과 코일 읽기 응답(08 01 01 17 12 1A)·코일 여러 개 쓰기(05 0F 00 06 00 06 02 17 00 DB 3E, 응답 … 34 4C)·FC10 응답(01 10 11 02 00 02 E5 34)의 CRC 는 계산값과 같다. 레지스터 읽기 응답(05 03 04 00 07 00 02)의 CRC 는 36 37 로 적혀 있으나 계산값은 8F F3 — 주소와는 무관.","en":"Addressing: coil and register numbers in the manual are 1-based, and each example notes «the start number is reduced by 1» (pp.4-168 to 4-173). Examples: read coils (p.4-168) 08 01 00 06 00 06 5C 90 → coils from 0007h (multi-function input 1); write coil (p.4-170) 0A 05 00 00 FF 00 8D 41 → coil 0001h (RUN command); read registers (p.4-169) 05 03 00 11 00 02 95 8A → 0012h (trip factor) and 0013h; FC06 (p.4-171) 05 06 12 02 00 32 AD 23 → 50 to 1203h (A003); FC10 (p.4-173) 01 10 11 02 00 02 04 00 04 93 E0 9E 9F → 300000 to 1103h/1104h (F002). CRCs of these frames and of the coil read response (08 01 01 17 12 1A), write coils (05 0F 00 06 00 06 02 17 00 DB 3E, response ... 34 4C) and FC10 response (01 10 11 02 00 02 E5 34) match calculation. The register read response (05 03 04 00 07 00 02) CRC is printed 36 37 but computes to 8F F3; this does not affect addressing."},{"ko":"함수 코드 01h·03h·05h·06h·08h·0Fh·10h. 03h·10h 는 한 번에 레지스터 4개(8바이트), 01h·0Fh 는 코일 32개까지 (p.4-165). 02h·04h 없음 — 읽기 전용 상태도 코일(01h)로 읽는다.","en":"Function codes 01h, 03h, 05h, 06h, 08h, 0Fh and 10h. 03h/10h handle up to 4 registers (8 bytes) per message, 01h/0Fh up to 32 coils (p.4-165). No 02h/04h; read-only status is read as coils (01h)."},{"ko":"출하값: C071 05 = 9600 bps, C072 국번 1, C073 8비트, C074 00 = 패리티 없음, C075 1 = 정지 1비트, C079 01 = ModBus-RTU (p.3-46). Modbus-RTU 는 데이터 8비트만, 한 줄에 32대까지 (p.4-145).","en":"Defaults: C071 05 = 9600 bps, C072 station 1, C073 8 bits, C074 00 = no parity, C075 1 = 1 stop bit, C079 01 = ModBus-RTU (p.3-46). Modbus-RTU uses 8 data bits only, up to 32 units per line (p.4-145)."},{"ko":"32비트 값은 (HIGH) 번호가 앞, (LOW) 번호가 뒤 — 상위 워드 먼저(ABCD). FC10 예(p.4-173)도 1103h 에 0004h, 1104h 에 93E0h 를 쓴다.","en":"32-bit values have the (HIGH) number first and the (LOW) number next, i.e. high word first (ABCD). The FC10 example (p.4-173) also writes 0004h to 1103h and 93E0h to 1104h."}]},"notes":[{"ko":"쪽 번호는 인쇄 쪽. 4장은 PDF 쪽 = 4-xxx 의 xxx + 119 (예 p.4-180 = PDF 299), p.3-46 = PDF 105.","en":"Page numbers are printed pages. In chapter 4, PDF page = xxx of 4-xxx + 119 (e.g. p.4-180 = PDF 299); p.3-46 = PDF 105."},{"ko":"통신으로 운전·주파수를 주려면 A002 = 03, A001 = 03 (p.4-170, p.4-180).","en":"To run and set frequency by communication set A002 = 03 and A001 = 03 (pp.4-170, 4-180)."},{"ko":"트립 요인 표(p.4-183)의 코드 2 는 «감속 중 과전압 보호» 로 적혀 있으나 같은 매뉴얼 고장 표(p.5-1)의 E02 는 감속 중 과전류라 어긋나 values 에서 뺐다.","en":"Code 2 in the trip factor list (p.4-183) reads «Overvoltage protection during deceleration», but E02 in the same manual's troubleshooting table (p.5-1) is overcurrent during deceleration, so code 2 is left out of values."},{"ko":"코일 0013h(RUN)는 넣지 않았다 — 이름은 «운전 중» 인데 설명 칸은 «1: 트립 중, 0: 정상» 이라 어긋난다 (p.4-176). 코일 0050h 가 WCO·WCOI 두 번 적혀 있어(p.4-179) 그 둘도 뺐다.","en":"Coil 0013h (RUN) is not included: the name says «during RUN» but the description reads «1: During trip, 0: Normal» (p.4-176). Coil 0050h is listed twice, for WCO and WCOI (p.4-179), so both are left out."},{"ko":"EEPROM 쓰기 모드 0902h 는 넣지 않았다 — 본문(p.4-174)은 0902h 에 1 을 쓰라고 하지만 레지스터 표(p.4-182)는 0901h~1000h 를 «사용 안 함» 으로 적는다.","en":"EEPROM write mode 0902h is not included: the text (p.4-174) says to write 1 to 0902h, but the register list (p.4-182) marks 0901h-1000h as «Not used»."},{"ko":"입력 전력(d014, 1012h)은 분해능 칸에 숫자가 없고, 적산 전력(d015, 1013h)은 분해능이 «0.1 [h]» 로 단위가 맞지 않아 넣지 않았다. 회전 방향 모니터(d003, 1004h)는 값이 FWD·STOP·REV 글자로만 적혀 있어 넣지 않았다 (p.4-184).","en":"Input power (d014, 1012h) has no number in the resolution column and integrated power (d015, 1013h) shows «0.1 [h]», a mismatched unit, so both are left out. The rotation direction monitor (d003, 1004h) lists only FWD/STOP/REV text without numeric codes, so it is left out (p.4-184)."},{"ko":"통신으로 쓴 값은 RAM 에만 있다. 남기려면 0900h 에 1 을 쓴다(Enter 명령, p.4-174).","en":"Values written by communication are in RAM only. To keep them write 1 to 0900h (Enter command, p.4-174)."}],"registers":[{"table":"coils","address":0,"manualAddress":"0001h","type":"bit","name":{"ko":"운전 지령","en":"RUN command"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 운전, 0 = 정지. A002 = 03 일 때 유효","en":"1 = run, 0 = stop. Valid when A002 = 03"},"ref":"p.4-176, p.4-170","source":0},{"table":"coils","address":1,"manualAddress":"0002h","type":"bit","name":{"ko":"회전 방향 지령","en":"Rotation direction command"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 역회전, 0 = 정회전. A002 = 03 일 때 유효","en":"1 = reverse, 0 = forward. Valid when A002 = 03"},"ref":"p.4-176","source":0},{"table":"coils","address":2,"manualAddress":"0003h","type":"bit","name":{"ko":"외부 트립(EXT)","en":"External trip (EXT)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 트립","en":"1 = trip"},"ref":"p.4-176","source":0},{"table":"coils","address":3,"manualAddress":"0004h","type":"bit","name":{"ko":"트립 리셋(RS)","en":"Trip reset (RS)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 리셋","en":"1 = reset"},"ref":"p.4-176","source":0},{"table":"coils","address":6,"manualAddress":"0007h","type":"bit","name":{"ko":"다기능 입력 단자 1","en":"Multi-function input terminal 1"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대 입력이 우선. 단자 2~8 은 코일 0008h~000Eh","en":"1 = ON. The control terminal block has priority. Terminals 2-8 are coils 0008h-000Eh"},"ref":"p.4-176, p.4-168","source":0},{"table":"coils","address":14,"manualAddress":"000Fh","type":"bit","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[1],"description":{"ko":"1 = 운전, 0 = 정지(d003 와 연동)","en":"1 = run, 0 = stop (interlocked with d003)"},"ref":"p.4-176","source":0},{"table":"coils","address":15,"manualAddress":"0010h","type":"bit","name":{"ko":"회전 방향","en":"Rotation direction"},"access":"r","fc":[1],"description":{"ko":"1 = 역회전, 0 = 정회전(d003 와 연동)","en":"1 = reverse, 0 = forward (interlocked with d003)"},"ref":"p.4-176","source":0},{"table":"coils","address":16,"manualAddress":"0011h","type":"bit","name":{"ko":"인버터 준비","en":"Inverter ready"},"access":"r","fc":[1],"description":{"ko":"1 = 준비, 0 = 준비 안 됨","en":"1 = ready, 0 = not ready"},"ref":"p.4-176","source":0},{"table":"coils","address":19,"manualAddress":"0014h","type":"bit","name":{"ko":"FA1(정속 도달)","en":"FA1 (constant speed arrival signal)"},"access":"r","fc":[1],"ref":"p.4-176","source":0},{"table":"coils","address":23,"manualAddress":"0018h","type":"bit","name":{"ko":"AL(알람 출력)","en":"AL (alarm output)"},"access":"r","fc":[1],"ref":"p.4-177","source":0},{"table":"coils","address":27,"manualAddress":"001Ch","type":"bit","name":{"ko":"UV(저전압 중)","en":"UV (signal during undervoltage)"},"access":"r","fc":[1],"ref":"p.4-177","source":0},{"table":"coils","address":68,"manualAddress":"0045h","type":"bit","name":{"ko":"IRDY(운전 준비)","en":"IRDY (operation ready signal)"},"access":"r","fc":[1],"ref":"p.4-179","source":0},{"table":"coils","address":71,"manualAddress":"0048h","type":"bit","name":{"ko":"MJA(중고장)","en":"MJA (fatal fault signal)"},"access":"r","fc":[1],"ref":"p.4-179","source":0},{"table":"coils","address":72,"manualAddress":"0049h","type":"bit","name":{"ko":"데이터 쓰는 중","en":"During data write"},"access":"r","fc":[1],"description":{"ko":"1 = 쓰는 중(Enter 명령 진행 확인용), 0 = 정상","en":"1 = writing (use to watch the Enter command), 0 = normal"},"ref":"p.4-179, p.4-174","source":0},{"table":"holding-registers","address":0,"manualAddress":"0001h","type":"u32","order":"ABCD","name":{"ko":"출력 주파수 설정/모니터(F001)","en":"Output frequency setting/monitor (F001)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0,"max":400},"description":{"ko":"0001h 상위·0002h 하위. 쓰기는 A001 = 03 일 때 유효","en":"0001h high, 0002h low. Writing is valid when A001 = 03"},"ref":"p.4-180","source":0},{"table":"holding-registers","address":2,"manualAddress":"0003h","type":"u16","name":{"ko":"인버터 상태 A","en":"Inverter status A"},"access":"r","fc":[3],"values":[{"value":0,"ko":"초기 상태","en":"Initial status"},{"value":2,"ko":"정지","en":"Stop"},{"value":3,"ko":"운전","en":"RUN"},{"value":4,"ko":"프리런 정지","en":"Free-run stop"},{"value":5,"ko":"조그","en":"Jogging"},{"value":6,"ko":"직류 제동","en":"DC injection braking"},{"value":7,"ko":"재시도","en":"Retry"},{"value":8,"ko":"트립","en":"Trip"},{"value":9,"ko":"저전압(UV)","en":"During UV"}],"ref":"p.4-180","source":0},{"table":"holding-registers","address":4,"manualAddress":"0005h","type":"u16","name":{"ko":"인버터 상태 C","en":"Inverter status C"},"access":"r","fc":[3],"values":[{"value":1,"ko":"정지","en":"Stop"},{"value":2,"ko":"감속","en":"Deceleration"},{"value":3,"ko":"정속","en":"Constant speed"},{"value":4,"ko":"가속","en":"Acceleration"},{"value":5,"ko":"정회전","en":"Forward"},{"value":6,"ko":"역회전","en":"Reverse"},{"value":7,"ko":"정→역 전환","en":"Forward to reverse"},{"value":8,"ko":"역→정 전환","en":"Reverse to forward"},{"value":9,"ko":"정회전 시동","en":"Forward run start"},{"value":10,"ko":"역회전 시동","en":"Reverse run start"}],"ref":"p.4-180","source":0},{"table":"holding-registers","address":5,"manualAddress":"0006h","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.4-180","source":0},{"table":"holding-registers","address":16,"manualAddress":"0011h","type":"u16","name":{"ko":"트립 횟수(d080)","en":"Fault frequency monitor (d080)"},"access":"r","fc":[3],"description":{"ko":"0~65535 회","en":"0-65535 times"},"ref":"p.4-180","source":0},{"table":"holding-registers","address":17,"manualAddress":"0012h","type":"u16","name":{"ko":"트립 모니터 1 요인(d081)","en":"Fault monitor 1 factor (d081)"},"access":"r","fc":[3],"values":[{"value":0,"ko":"트립 없음","en":"No trip factor"},{"value":1,"ko":"정속 중 과전류","en":"Overcurrent protection during constant speed"},{"value":3,"ko":"가속 중 과전류","en":"Overcurrent protection during acceleration"},{"value":4,"ko":"정지 중 과전류","en":"Overcurrent protection during stop"},{"value":5,"ko":"과부하 보호","en":"Overload protection"},{"value":6,"ko":"제동 저항 과부하","en":"Braking resistor overload protection"},{"value":7,"ko":"과전압 보호","en":"Overvoltage protection"},{"value":8,"ko":"EEPROM 오류","en":"EEPROM error"},{"value":9,"ko":"저전압 보호","en":"Undervoltage protection"},{"value":10,"ko":"CT 오류","en":"CT error"},{"value":11,"ko":"CPU 오류","en":"CPU error"},{"value":12,"ko":"외부 트립","en":"External trip"},{"value":13,"ko":"USP 오류","en":"USP error"},{"value":14,"ko":"지락 보호","en":"Grounding protection"},{"value":15,"ko":"입력 과전압 보호","en":"Incoming overvoltage protection"},{"value":16,"ko":"순시 정전 보호","en":"Momentary power interruption protection"},{"value":20,"ko":"파워 모듈 이상 온도(팬 정지)","en":"Power module abnormal temperature (during FAN stop)"},{"value":21,"ko":"파워 모듈 이상 온도","en":"Power module abnormal temperature"},{"value":23,"ko":"게이트 어레이 통신 오류","en":"Gate array communications error"},{"value":24,"ko":"입력 결상 보호","en":"Input phase loss protection"},{"value":25,"ko":"주회로 오류","en":"Main circuit error"},{"value":30,"ko":"IGBT 오류","en":"IGBT error"},{"value":35,"ko":"서미스터 오류","en":"Thermistor error"},{"value":36,"ko":"제동 오류","en":"Brake error addition"},{"value":37,"ko":"비상 차단","en":"Emergency shutoff error"},{"value":38,"ko":"저속 영역 전자 서멀","en":"Low-speed-range electronic thermal"}],"description":{"ko":"가장 최근 트립. 60~69 = 옵션 1 오류 0~9, 70~79 = 옵션 2 오류 0~9. 트립 2~6 은 001Ch·0026h·0030h·003Ah·0044h 부터 같은 꼴. 읽기 예(p.4-169) 응답 0007h = 과전압(E07)","en":"Latest trip. 60-69 = option 1 errors 0-9, 70-79 = option 2 errors 0-9. Trips 2-6 follow the same layout from 001Ch, 0026h, 0030h, 003Ah, 0044h. The read example (p.4-169) returns 0007h = overvoltage (E07)"},"ref":"p.4-180, p.4-183, p.4-169","source":0},{"table":"holding-registers","address":18,"manualAddress":"0013h","type":"u16","name":{"ko":"트립 모니터 1 인버터 상태","en":"Fault monitor 1 inverter status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"리셋 중","en":"During reset"},{"value":1,"ko":"정지 중","en":"During stop"},{"value":2,"ko":"감속 중","en":"During deceleration"},{"value":3,"ko":"정속 중","en":"During constant speed"},{"value":4,"ko":"가속 중","en":"During acceleration"},{"value":5,"ko":"0 Hz 운전","en":"Operates at frequency = 0"},{"value":6,"ko":"시동 중","en":"During startup"},{"value":7,"ko":"직류 제동 중","en":"During DB"},{"value":8,"ko":"과부하 제한 중","en":"During overload limit"},{"value":9,"ko":"SON/FOC 중","en":"During SON/FOC"}],"description":{"ko":"읽기 예(p.4-169) 응답 0002h = 감속 중","en":"The read example (p.4-169) returns 0002h = during deceleration"},"ref":"p.4-180, p.4-183, p.4-169","source":0},{"table":"holding-registers","address":19,"manualAddress":"0014h","type":"u32","order":"ABCD","name":{"ko":"트립 모니터 1 주파수","en":"Fault monitor 1 frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"range":{"min":0,"max":400},"description":{"ko":"0014h 상위·0015h 하위","en":"0014h high, 0015h low"},"ref":"p.4-180","source":0},{"table":"holding-registers","address":21,"manualAddress":"0016h","type":"u16","name":{"ko":"트립 모니터 1 전류","en":"Fault monitor 1 current"},"unit":"A","scale":0.1,"access":"r","fc":[3],"description":{"ko":"트립 때 출력 전류","en":"Output current at tripping"},"ref":"p.4-180","source":0},{"table":"holding-registers","address":22,"manualAddress":"0017h","type":"u16","name":{"ko":"트립 모니터 1 직류 전압","en":"Fault monitor 1 voltage"},"unit":"V","access":"r","fc":[3],"description":{"ko":"트립 때 직류 입력 전압","en":"DC input voltage at tripping"},"ref":"p.4-180","source":0},{"table":"holding-registers","address":77,"manualAddress":"004Eh","type":"u16","name":{"ko":"경고 코드(d090)","en":"Warning monitor (d090)"},"access":"r","fc":[3],"range":{"min":0,"max":385},"ref":"p.4-182","source":0},{"table":"holding-registers","address":2303,"manualAddress":"0900h","type":"u16","name":{"ko":"EEPROM 쓰기(Enter 명령)","en":"EEPROM write (Enter command)"},"access":"w","fc":[6,16],"values":[{"value":0,"ko":"모터 상수 재계산","en":"Motor parameter recalculation"},{"value":1,"ko":"설정값을 EEPROM 에 저장","en":"Set value storage in EEPROM"}],"description":{"ko":"그 밖의 값 = 재계산 + 저장. 통신으로 쓴 값은 RAM 에만 있어 전원을 끄면 사라진다. 진행은 코일 0049h 로 본다. EEPROM 수명 약 10만 회","en":"Other values = recalculation and storage. Values written by communication stay in RAM and are lost at power off. Watch coil 0049h for progress. EEPROM life about 100,000 writes"},"ref":"p.4-182, p.4-174","source":0},{"table":"holding-registers","address":4096,"manualAddress":"1001h","type":"u32","order":"ABCD","name":{"ko":"출력 주파수 모니터(d001)","en":"Output frequency monitor (d001)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"range":{"min":0,"max":400},"description":{"ko":"1001h 상위·1002h 하위","en":"1001h high, 1002h low"},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4098,"manualAddress":"1003h","type":"u16","name":{"ko":"출력 전류 모니터(d002)","en":"Output current monitor (d002)"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":9999},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4106,"manualAddress":"100Bh","type":"s32","order":"ABCD","name":{"ko":"실주파수 모니터(d008)","en":"Real frequency monitor (d008)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"range":{"min":-400,"max":400},"description":{"ko":"100Bh 상위·100Ch 하위","en":"100Bh high, 100Ch low"},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4111,"manualAddress":"1010h","type":"s16","name":{"ko":"출력 토크 모니터(d012)","en":"Output torque monitor (d012)"},"unit":"%","access":"r","fc":[3],"range":{"min":-200,"max":200},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4112,"manualAddress":"1011h","type":"u16","name":{"ko":"출력 전압 모니터(d013)","en":"Output voltage monitor (d013)"},"unit":"V","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":600},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4116,"manualAddress":"1015h","type":"u32","order":"ABCD","name":{"ko":"누적 운전 시간(d016)","en":"Total RUN time (d016)"},"unit":"h","access":"r","fc":[3],"range":{"min":0,"max":999999},"description":{"ko":"1015h 상위·1016h 하위","en":"1015h high, 1016h low"},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4120,"manualAddress":"1019h","type":"s16","name":{"ko":"방열핀 온도(d018)","en":"Fin temperature monitor (d018)"},"unit":"°C","scale":0.1,"access":"r","fc":[3],"range":{"min":-20,"max":200},"ref":"p.4-184","source":0},{"table":"holding-registers","address":4133,"manualAddress":"1026h","type":"u16","name":{"ko":"직류 전압 모니터(d102)","en":"DC voltage monitor (d102)"},"unit":"V","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":999.9},"ref":"p.4-185","source":0},{"table":"holding-registers","address":4135,"manualAddress":"1028h","type":"u16","name":{"ko":"전자 서멀 모니터(d104)","en":"Electronic thermal monitor (d104)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":100},"ref":"p.4-185","source":0},{"table":"holding-registers","address":4354,"manualAddress":"1103h","type":"u32","order":"ABCD","name":{"ko":"가속 시간 1(F002)","en":"Acceleration time 1 (F002)"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0.01,"max":3600},"description":{"ko":"1103h 상위·1104h 하위. FC10 예(p.4-173)가 시작 11 02 에 00 04 93 E0(300000 = 3000.00 s)을 쓴다. 100.0 s 이상이면 소수 둘째 자리는 무시","en":"1103h high, 1104h low. The FC10 example (p.4-173) writes 00 04 93 E0 (300000 = 3000.00 s) at start 11 02. From 100.0 s the second decimal place is ignored"},"ref":"p.4-185, p.4-173","source":0},{"table":"holding-registers","address":4356,"manualAddress":"1105h","type":"u32","order":"ABCD","name":{"ko":"감속 시간 1(F003)","en":"Deceleration time 1 (F003)"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0.01,"max":3600},"description":{"ko":"1105h 상위·1106h 하위","en":"1105h high, 1106h low"},"ref":"p.4-185","source":0},{"table":"holding-registers","address":4608,"manualAddress":"1201h","type":"u16","name":{"ko":"주파수 지령 선택(A001)","en":"Frequency reference selection (A001)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"오퍼레이터 볼륨","en":"Digital Operator (FREQ adjuster)"},{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터(F001)","en":"Digital Operator (F001)"},{"value":3,"ko":"RS485(Modbus 통신)","en":"RS485 (ModBus communication)"},{"value":4,"ko":"옵션 1","en":"Option 1"},{"value":5,"ko":"옵션 2","en":"Option 2"},{"value":6,"ko":"펄스열 주파수","en":"Pulse train frequency"},{"value":7,"ko":"EzSQ(드라이브 프로그래밍)","en":"EzSQ (Drive Programming)"},{"value":10,"ko":"연산 기능 결과","en":"(Math) Operation function result"}],"ref":"p.4-186","source":0},{"table":"holding-registers","address":4609,"manualAddress":"1202h","type":"u16","name":{"ko":"운전 지령 선택(A002)","en":"RUN command selection (A002)"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터(F001)","en":"Digital Operator (F001)"},{"value":3,"ko":"RS485(Modbus 통신)","en":"RS485 (ModBus communication)"},{"value":4,"ko":"옵션 1","en":"Option 1"},{"value":5,"ko":"옵션 2","en":"Option 2"}],"ref":"p.4-186","source":0},{"table":"holding-registers","address":4610,"manualAddress":"1203h","type":"u16","name":{"ko":"기저 주파수(A003)","en":"Base frequency (A003)"},"unit":"Hz","access":"rw","fc":[3,6,16],"description":{"ko":"30~최고 주파수. FC06 예(p.4-171)가 05 06 12 02 00 32 AD 23 으로 50 Hz 를 쓴다","en":"30 to maximum frequency. The FC06 example (p.4-171) writes 50 Hz with 05 06 12 02 00 32 AD 23"},"ref":"p.4-186, p.4-171","source":0},{"table":"holding-registers","address":4611,"manualAddress":"1204h","type":"u16","name":{"ko":"최고 주파수(A004)","en":"Maximum frequency (A004)"},"unit":"Hz","access":"rw","fc":[3,6,16],"range":{"min":30,"max":400},"ref":"p.4-186","source":0},{"table":"holding-registers","address":4686,"manualAddress":"124Fh","type":"u32","order":"ABCD","name":{"ko":"주파수 상한(A061)","en":"Frequency upper limit (A061)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"124Fh 상위·1250h 하위. 0.00 또는 하한~최고 주파수","en":"124Fh high, 1250h low. 0.00 or lower limit to maximum frequency"},"ref":"p.4-189","source":0},{"table":"holding-registers","address":4688,"manualAddress":"1251h","type":"u32","order":"ABCD","name":{"ko":"주파수 하한(A062)","en":"Frequency lower limit (A062)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"1251h 상위·1252h 하위. 0.00 또는 시동 주파수~상한","en":"1251h high, 1252h low. 0.00 or starting frequency to upper limit"},"ref":"p.4-189","source":0},{"table":"holding-registers","address":5194,"manualAddress":"144Bh","type":"u16","name":{"ko":"통신 속도(C071)","en":"Communication speed selection (C071)"},"access":"rw","fc":[3,6,16],"values":[{"value":2,"ko":"루프백 시험","en":"Loop-back test"},{"value":3,"ko":"2400 bps","en":"2400 bps"},{"value":4,"ko":"4800 bps","en":"4800 bps"},{"value":5,"ko":"9600 bps","en":"9600 bps"},{"value":6,"ko":"19200 bps","en":"19200 bps"}],"description":{"ko":"출하값 05","en":"Default 05"},"ref":"p.4-206, p.3-46","source":0},{"table":"holding-registers","address":5195,"manualAddress":"144Ch","type":"u16","name":{"ko":"국번(C072)","en":"Communication station No. (C072)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":247},"description":{"ko":"출하값 1","en":"Default 1"},"ref":"p.4-206, p.3-46","source":0},{"table":"holding-registers","address":5197,"manualAddress":"144Eh","type":"u16","name":{"ko":"패리티(C074)","en":"Communication parity (C074)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"No parity"},{"value":1,"ko":"짝수","en":"Even"},{"value":2,"ko":"홀수","en":"Odd"}],"description":{"ko":"출하값 00","en":"Default 00"},"ref":"p.4-206, p.3-46","source":0},{"table":"holding-registers","address":5198,"manualAddress":"144Fh","type":"u16","name":{"ko":"정지 비트(C075)","en":"Communication stop bit (C075)"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"1 비트","en":"1 bit"},{"value":2,"ko":"2 비트","en":"2 bits"}],"description":{"ko":"출하값 1","en":"Default 1"},"ref":"p.4-206, p.3-46","source":0},{"table":"holding-registers","address":5200,"manualAddress":"1451h","type":"u16","name":{"ko":"통신 오류 타임아웃(C077)","en":"Communication error timeout (C077)"},"unit":"s","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":99.99},"description":{"ko":"출하값 0.00. 시간 안에 다음 질의가 없으면 C076 에 따라 동작(E41)","en":"Default 0.00. If no query arrives within the time, the drive acts per C076 (E41)"},"ref":"p.4-207, p.4-164","source":0}],"sources":[{"title":"OMRON RX Series 3G3RX User's Manual (Cat. No. I560-E2-05A)","publisher":"OMRON Corporation","edition":{"ko":"Cat. No. I560-E2-05A (개정 05 = 2012년 12월)","en":"Cat. No. I560-E2-05A (revision 05 = December 2012)"},"url":"https://files.omron.eu/downloads/latest/manual/en/i560_3g3rx_users_manual_en.pdf","pages":{"ko":"4-4 통신 기능 인쇄 p.4-144~4-207(PDF 263~326), 파라미터 목록 p.3-46(PDF 105)","en":"4-4 Communication function printed pp.4-144 to 4-207 (PDF 263-326), parameter list p.3-46 (PDF 105)"},"checked":"2026-10-29"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"omron/e5cc","manufacturer":{"ko":"오므론","en":"OMRON"},"model":"E5CC","models":["E5CC","E5EC","E5AC","E5DC","E5GC"],"kind":"temperature-controller","title":{"ko":"오므론 E5CC 계열 온도 조절기 (RS-485 Modbus RTU)","en":"OMRON E5CC series temperature controller (RS-485 Modbus RTU)"},"summary":{"ko":"E5□C(E5CC·E5EC·E5AC·E5DC·E5GC) 통신 모델. 2바이트 모드 주소(2000h~): PV·상태·SP·경보값·PID·입력 종류, 운전 명령은 0000h 에 FC06","en":"E5□C (E5CC, E5EC, E5AC, E5DC, E5GC) communication models. Two-byte mode addresses (2000h-): PV, status, SP, alarm values, PID, input type; operation commands via FC06 to 0000h"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[9600,19200,38400,57600],"dataBits":8,"parity":"even","stopBits":1,"unit":1,"unitRange":[1,99],"maxRegisters":106,"addressing":"zero","notes":[{"ko":"주소 체계: 매뉴얼 읽기 예(4-9 (PDF 87))는 01 03 20 00 00 01 8F CA 로 PV(2000h)를 읽고 01 03 02 03 E8 B8 FA(100.0℃)를 받는다. 쓰기 예(4-12)는 01 10 21 05 00 02 04 03 E8 FC 18 66 BB 로 2105h·2106h 에 1000·−1000 을 쓰고, 운전 명령 예(4-14)는 01 06 00 00 01 01 49 9A(STOP). 매뉴얼 주소 = 프레임 주소(0 기준). CRC 도 계산값과 맞다.","en":"Addressing: the read example (4-9 (PDF 87)) sends 01 03 20 00 00 01 8F CA to read PV (2000h) and gets 01 03 02 03 E8 B8 FA (100.0 °C). The write example (4-12) 01 10 21 05 00 02 04 03 E8 FC 18 66 BB writes 1000/-1000 to 2105h/2106h; the operation command example (4-14) is 01 06 00 00 01 01 49 9A (stop). Manual address = frame address (0-based). CRCs match calculation."},{"ko":"출하 프로토콜은 CompoWay/F — 통신 설정 레벨에서 PSEL 을 Mod 로 바꾸고 리셋해야 Modbus 로 동작한다. 출하값: 국번 1, 9600 bps, 짝수 패리티. Modbus 에서는 데이터 8비트, 정지 비트는 패리티 있음 1·없음 2 로 고정 (1-6 (PDF 28)).","en":"Factory protocol is CompoWay/F: set PSEL to Mod in the communications setting level and reset. Defaults: unit 1, 9600 bps, even parity. In Modbus the data length is 8 bits and stop bits are fixed to 1 with parity, 2 without (1-6 (PDF 28))."},{"ko":"함수 코드 03·06·08·10. 2바이트 모드(이 표)는 한 번에 106개 읽기·104개 쓰기. 4바이트 모드는 0000h~ 의 다른 주소(값 하나 = 2워드)를 쓴다. 파라미터를 쓰려면 먼저 «통신 쓰기» 를 ON(운전 명령 0001h)으로.","en":"Function codes 03, 06, 08, 10. Two-byte mode (this table): up to 106 read / 104 write per request. Four-byte mode uses different addresses from 0000h (two words per value). Turn Communications Writing ON first (operation command 0001h) to write parameters."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"0000","type":"u16","name":{"ko":"운전 명령","en":"Operation command"},"access":"w","fc":[6],"values":[{"value":0,"ko":"통신 쓰기 OFF","en":"Communications writing OFF"},{"value":1,"ko":"통신 쓰기 ON","en":"Communications writing ON"},{"value":256,"ko":"RUN","en":"Run"},{"value":257,"ko":"STOP","en":"Stop"},{"value":768,"ko":"AT 취소","en":"AT cancel"},{"value":769,"ko":"100% AT 실행","en":"100% AT execute"},{"value":770,"ko":"40% AT 실행","en":"40% AT execute"},{"value":1024,"ko":"백업 모드","en":"Backup mode"},{"value":1025,"ko":"RAM 쓰기 모드","en":"RAM write mode"},{"value":1280,"ko":"RAM 데이터 저장","en":"Save RAM data"},{"value":1536,"ko":"소프트웨어 리셋","en":"Software reset"},{"value":1792,"ko":"설정 영역 1 로 이동","en":"Move to setup area 1"},{"value":2048,"ko":"보호 레벨로 이동","en":"Move to protect level"},{"value":2304,"ko":"자동 모드","en":"Automatic mode"},{"value":2305,"ko":"수동 모드","en":"Manual mode"},{"value":2816,"ko":"파라미터 초기화","en":"Parameter initialization"}],"description":{"ko":"FC06 전용. 쓰기 값 = 명령 코드(상위 바이트) + 관련 정보(하위 바이트), 예 STOP = 0101h. 매뉴얼 예: 01 06 00 00 01 01 49 9A. 다단 SP(02xx)·경보 래치 해제(0Cxx) 등은 2-16~2-17 표 참고","en":"FC06 only. Value = command code (high byte) + related information (low byte), e.g. STOP = 0101h. Manual example: 01 06 00 00 01 01 49 9A. Multi-SP (02xx), alarm latch cancel (0Cxx) etc. in the table on pp.2-16 to 2-17"},"ref":"4-12, 4-14 (PDF 90, 92)","source":0},{"table":"holding-registers","address":8192,"manualAddress":"2000","type":"s16","name":{"ko":"PV(현재값)","en":"PV (process value)"},"access":"r","fc":[3],"description":{"ko":"소수점 없는 정수, 예 100.0℃ = 03E8h(매뉴얼 읽기 예)","en":"Integer without decimal point, e.g. 100.0 °C = 03E8h (manual read example)"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8193,"manualAddress":"2001","type":"u16","name":{"ko":"상태(하위 16비트)","en":"Status (lower 16 bits)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"히터 과전류(CT1)","en":"Heater overcurrent (CT1)"},{"bit":1,"ko":"히터 전류 홀드(CT1)","en":"Heater current hold (CT1)"},{"bit":2,"ko":"A/D 변환 오류","en":"A/D converter error"},{"bit":3,"ko":"HS 경보(CT1)","en":"HS alarm (CT1)"},{"bit":4,"ko":"RSP 입력 오류","en":"RSP input error"},{"bit":6,"ko":"입력 오류","en":"Input error"},{"bit":7,"ko":"포텐셔미터 입력 오류","en":"Potentiometer input error"},{"bit":8,"ko":"제어 출력(가열)/열림 출력","en":"Control output (heating)/open output"},{"bit":9,"ko":"제어 출력(냉각)/닫힘 출력","en":"Control output (cooling)/close output"},{"bit":10,"ko":"HB 경보(CT1)","en":"HB alarm (CT1)"},{"bit":11,"ko":"HB 경보(CT2)","en":"HB alarm (CT2)"},{"bit":12,"ko":"경보 1","en":"Alarm 1"},{"bit":13,"ko":"경보 2","en":"Alarm 2"},{"bit":14,"ko":"경보 3","en":"Alarm 3"},{"bit":15,"ko":"프로그램 끝 출력","en":"Program end output"}],"description":{"ko":"1 = 발생/ON","en":"1 = generated/ON"},"ref":"5-2, 3-25 (PDF 96, 77)","source":0},{"table":"holding-registers","address":8194,"manualAddress":"2002","type":"s16","name":{"ko":"내부 SP","en":"Internal set point"},"access":"r","fc":[3],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410h(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410h (decimal point monitor) / input type"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8195,"manualAddress":"2003","type":"u16","name":{"ko":"히터 전류 1 모니터","en":"Heater current 1 value monitor"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":55},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8196,"manualAddress":"2004","type":"s16","name":{"ko":"MV 모니터(가열)","en":"MV monitor (heating)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"range":{"min":-5,"max":105},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8197,"manualAddress":"2005","type":"u16","name":{"ko":"MV 모니터(냉각)","en":"MV monitor (cooling)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":105},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8451,"manualAddress":"2103","type":"s16","name":{"ko":"SP(목표값)","en":"Set point"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410h(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410h (decimal point monitor) / input type"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8452,"manualAddress":"2104","type":"s16","name":{"ko":"경보값 1","en":"Alarm value 1"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"소수점은 입력 설정을 따른다","en":"Decimal point follows the input setting"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8453,"manualAddress":"2105","type":"s16","name":{"ko":"경보 상한값 1","en":"Alarm value upper limit 1"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"소수점은 입력 설정을 따른다","en":"Decimal point follows the input setting"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8454,"manualAddress":"2106","type":"s16","name":{"ko":"경보 하한값 1","en":"Alarm value lower limit 1"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"소수점은 입력 설정을 따른다","en":"Decimal point follows the input setting"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8455,"manualAddress":"2107","type":"s16","name":{"ko":"경보값 2","en":"Alarm value 2"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"소수점은 입력 설정을 따른다","en":"Decimal point follows the input setting"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8456,"manualAddress":"2108","type":"s16","name":{"ko":"경보 상한값 2","en":"Alarm value upper limit 2"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"소수점은 입력 설정을 따른다","en":"Decimal point follows the input setting"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":8457,"manualAddress":"2109","type":"s16","name":{"ko":"경보 하한값 2","en":"Alarm value lower limit 2"},"access":"rw","fc":[3,6,16],"range":{"min":-1999,"max":9999},"description":{"ko":"소수점은 입력 설정을 따른다","en":"Decimal point follows the input setting"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":9220,"manualAddress":"2404","type":"u16","name":{"ko":"다단 SP 번호 모니터","en":"Multi-SP No. monitor"},"access":"r","fc":[3],"range":{"min":0,"max":7},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":9223,"manualAddress":"2407","type":"u16","name":{"ko":"상태(상위 16비트)","en":"Status (upper 16 bits)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"이벤트 입력 1","en":"Event input 1"},{"bit":1,"ko":"이벤트 입력 2","en":"Event input 2"},{"bit":2,"ko":"이벤트 입력 3","en":"Event input 3"},{"bit":3,"ko":"이벤트 입력 4","en":"Event input 4"},{"bit":4,"ko":"쓰기 모드(0 백업 / 1 RAM 쓰기)","en":"Write mode (0 backup / 1 RAM write)"},{"bit":5,"ko":"비휘발 메모리(1 = RAM ≠ 비휘발)","en":"Non-volatile memory (1 = RAM differs)"},{"bit":6,"ko":"설정 영역(0 = 영역 0 / 1 = 영역 1)","en":"Setup area (0 = area 0 / 1 = area 1)"},{"bit":7,"ko":"AT 실행 중","en":"AT in progress"},{"bit":8,"ko":"RUN/STOP(0 = RUN / 1 = STOP)","en":"RUN/STOP (0 = run / 1 = stop)"},{"bit":9,"ko":"통신 쓰기 허용","en":"Communications writing enabled"},{"bit":10,"ko":"자동/수동(1 = 수동)","en":"Auto/manual (1 = manual)"},{"bit":11,"ko":"프로그램 시작","en":"Program start"},{"bit":12,"ko":"히터 과전류(CT2)","en":"Heater overcurrent (CT2)"},{"bit":13,"ko":"히터 전류 홀드(CT2)","en":"Heater current hold (CT2)"},{"bit":15,"ko":"HS 경보(CT2)","en":"HS alarm (CT2)"}],"description":{"ko":"32비트 상태의 비트 16~31 을 비트 0~15 로 읽는다","en":"Bits 16-31 of the 32-bit status, read as bits 0-15"},"ref":"5-2, 3-25 (PDF 96, 77)","source":0},{"table":"holding-registers","address":9232,"manualAddress":"2410","type":"u16","name":{"ko":"소수점 모니터","en":"Decimal point monitor"},"access":"r","fc":[3],"range":{"min":0,"max":3},"description":{"ko":"소수점 아래 자릿수","en":"Number of decimal places"},"ref":"5-2 (PDF 96)","source":0},{"table":"holding-registers","address":10752,"manualAddress":"2A00","type":"u16","name":{"ko":"비례대","en":"Proportional band"},"scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":999.9},"ref":"5-6 (PDF 100)","source":0},{"table":"holding-registers","address":10753,"manualAddress":"2A01","type":"u16","name":{"ko":"적분 시간","en":"Integral time"},"unit":"s","access":"rw","fc":[3,6,16],"description":{"ko":"단위는 적분/미분 시간 단위 설정에 따라 1 s(0~9999) 또는 0.1 s(0.0~999.9)","en":"1 s (0-9999) or 0.1 s (0.0-999.9) depending on the integral/derivative time unit setting"},"ref":"5-6 (PDF 100)","source":0},{"table":"holding-registers","address":10754,"manualAddress":"2A02","type":"u16","name":{"ko":"미분 시간","en":"Derivative time"},"unit":"s","access":"rw","fc":[3,6,16],"description":{"ko":"단위는 적분 시간과 같다","en":"Unit as for the integral time"},"ref":"5-6 (PDF 100)","source":0},{"table":"holding-registers","address":10757,"manualAddress":"2A05","type":"s16","name":{"ko":"MV 상한","en":"MV upper limit"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"ref":"5-6 (PDF 100)","source":0},{"table":"holding-registers","address":10758,"manualAddress":"2A06","type":"s16","name":{"ko":"MV 하한","en":"MV lower limit"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"ref":"5-6 (PDF 100)","source":0},{"table":"holding-registers","address":11264,"manualAddress":"2C00","type":"u16","name":{"ko":"입력 종류","en":"Input type"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"Pt100 −200~850℃","en":"Pt100 -200 to 850 °C"},{"value":1,"ko":"Pt100 −199.9~500.0℃","en":"Pt100 -199.9 to 500.0 °C"},{"value":2,"ko":"Pt100 0.0~100.0℃","en":"Pt100 0.0 to 100.0 °C"},{"value":3,"ko":"JPt100 −199.9~500.0℃","en":"JPt100 -199.9 to 500.0 °C"},{"value":4,"ko":"JPt100 0.0~100.0℃","en":"JPt100 0.0 to 100.0 °C"},{"value":5,"ko":"K −200~1300℃","en":"K -200 to 1300 °C"},{"value":6,"ko":"K −20.0~500.0℃","en":"K -20.0 to 500.0 °C"},{"value":7,"ko":"J −100~850℃","en":"J -100 to 850 °C"},{"value":8,"ko":"J −20.0~400.0℃","en":"J -20.0 to 400.0 °C"},{"value":9,"ko":"T −200~400℃","en":"T -200 to 400 °C"},{"value":10,"ko":"T −199.9~400.0℃","en":"T -199.9 to 400.0 °C"},{"value":11,"ko":"E −200~600℃","en":"E -200 to 600 °C"},{"value":12,"ko":"L −100~850℃","en":"L -100 to 850 °C"},{"value":13,"ko":"U −200~400℃","en":"U -200 to 400 °C"},{"value":14,"ko":"U −199.9~400.0℃","en":"U -199.9 to 400.0 °C"},{"value":15,"ko":"N −200~1300℃","en":"N -200 to 1300 °C"},{"value":16,"ko":"R 0~1700℃","en":"R 0 to 1700 °C"},{"value":17,"ko":"S 0~1700℃","en":"S 0 to 1700 °C"},{"value":18,"ko":"B 100~1800℃","en":"B 100 to 1800 °C"},{"value":19,"ko":"W 0~2300℃","en":"W 0 to 2300 °C"},{"value":20,"ko":"PLII 0~1300℃","en":"PLII 0 to 1300 °C"},{"value":21,"ko":"적외선 센서 K 140℉/60℃","en":"Infrared sensor K 140 °F/60 °C"},{"value":22,"ko":"적외선 센서 K 240℉/120℃","en":"Infrared sensor K 240 °F/120 °C"},{"value":23,"ko":"적외선 센서 K 280℉/140℃","en":"Infrared sensor K 280 °F/140 °C"},{"value":24,"ko":"적외선 센서 K 440℉/220℃","en":"Infrared sensor K 440 °F/220 °C"},{"value":25,"ko":"4~20 mA","en":"4-20 mA"},{"value":26,"ko":"0~20 mA","en":"0-20 mA"},{"value":27,"ko":"1~5 V","en":"1-5 V"},{"value":28,"ko":"0~5 V","en":"0-5 V"},{"value":29,"ko":"0~10 V","en":"0-10 V"},{"value":30,"ko":"0~50 mV(E5CC-U 2.2판 이후만)","en":"0-50 mV (E5CC-U version 2.2 or later only)"}],"description":{"ko":"초기 설정 레벨 — 쓰려면 설정 영역 1 로 이동(운전 명령 0700h). ℉ 범위는 매뉴얼 표 참고","en":"Initial setting level: move to setup area 1 (operation command 0700h) to write. °F ranges in the manual table"},"ref":"5-7 (PDF 101)","source":0},{"table":"holding-registers","address":11265,"manualAddress":"2C01","type":"u16","name":{"ko":"온도 단위","en":"Temperature unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"5-7 (PDF 101)","source":0},{"table":"holding-registers","address":11535,"manualAddress":"2D0F","type":"s16","name":{"ko":"SP 상한","en":"SP upper limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410h(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410h (decimal point monitor) / input type"},"ref":"5-7 (PDF 101)","source":0},{"table":"holding-registers","address":11536,"manualAddress":"2D10","type":"s16","name":{"ko":"SP 하한","en":"SP lower limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410h(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410h (decimal point monitor) / input type"},"ref":"5-7 (PDF 101)","source":0}],"notes":[{"ko":"값은 소수점 없는 정수다(예 100.0 → 1000). PV·SP·경보값의 소수점 자리는 입력 종류·소수점 설정을 따르므로 scale 을 넣지 않았다.","en":"Values are integers without decimal point (e.g. 100.0 → 1000). PV, SP and alarm decimal places follow the input type / decimal point setting, so no scale is given."},{"ko":"RS-485 통신 기능이 있는 형번만 해당. 출력·경보·히터 전류 항목은 형번(옵션)에 따라 없을 수 있다.","en":"Only models with RS-485 communications. Output, alarm and heater current items depend on the model options."}],"sources":[{"title":"E5□C Digital Temperature Controllers Communications Manual","publisher":"OMRON Corporation","edition":{"ko":"Cat. No. H175-E1-17","en":"Cat. No. H175-E1-17"},"url":"https://files.omron.eu/downloads/latest/manual/en/h175_e5_c_communications_manual_en.pdf","pages":{"ko":"통신 설정 1-6 (PDF 28), 운전 명령 2-16~2-17 (PDF 46-47), 상태 3-23~3-25 (PDF 75-77), Modbus 절차 4-1~4-15 (PDF 79-93), 변수 표 5-2~5-7 (PDF 96-101)","en":"Communications settings 1-6 (PDF 28), operation commands 2-16 to 2-17 (PDF 46-47), status 3-23 to 3-25 (PDF 75-77), Modbus procedure 4-1 to 4-15 (PDF 79-93), variable list 5-2 to 5-7 (PDF 96-101)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"omron/e5cn","manufacturer":{"ko":"오므론","en":"OMRON"},"model":"E5CN","models":["E5CN","E5AN","E5EN","E5GN"],"kind":"temperature-controller","title":{"ko":"오므론 E5CN 계열 온도 조절기 기본형 (RS-485 Modbus RTU)","en":"OMRON E5CN series basic temperature controller (RS-485 Modbus RTU)"},"summary":{"ko":"E5□N 기본형(E5CN·E5AN·E5EN·E5GN) 통신 모델. 2바이트 모드 주소(2000h~): PV·상태·SP·경보값·PID·입력 종류, 운전 명령은 0000h 에 FC06","en":"E5□N basic type (E5CN, E5AN, E5EN, E5GN) communication models. Two-byte mode addresses (2000h-): PV, status, SP, alarm values, PID, input type; operation commands via FC06 to 0000h"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600],"dataBits":8,"parity":"even","stopBits":2,"unit":1,"unitRange":[1,99],"maxRegisters":106,"addressing":"zero","notes":[{"ko":"주소 체계: 읽기 예 2바이트 모드(5-11 (PDF 91))는 01 03 20 00 00 01 8F CA 로 PV(2000h)를 읽고 01 03 02 03 E8 B8 FA(100.0 ℃)를 받는다. 쓰기 예(5-13 (PDF 93))는 01 10 21 05 00 02 04 03 E8 FC 18 66 BB 로 2105h·2106h 에 1000·−1000 을 쓰고(응답 01 10 21 05 00 02 5B F5), 운전 명령 예(5-16 (PDF 96))는 01 06 00 00 01 01 49 9A(STOP). 4바이트 모드 예(01 03 00 00 00 02 C4 0B → 01 03 04 00 00 03 E8 FA 8D, 01 10 01 0A 00 04 08 … 8D E9 → 01 10 01 0A 00 04 E0 34)까지 모두 CRC 가 계산값과 같다. 매뉴얼 주소 = 프레임 주소(0 기준).","en":"Addressing: the two-byte mode read example (5-11 (PDF 91)) sends 01 03 20 00 00 01 8F CA to read PV (2000h) and gets 01 03 02 03 E8 B8 FA (100.0 °C). The write example (5-13 (PDF 93)) 01 10 21 05 00 02 04 03 E8 FC 18 66 BB writes 1000/-1000 to 2105h/2106h (response 01 10 21 05 00 02 5B F5); the operation command example (5-16 (PDF 96)) is 01 06 00 00 01 01 49 9A (stop). All CRCs, including the four-byte mode examples (01 03 00 00 00 02 C4 0B -> 01 03 04 00 00 03 E8 FA 8D; 01 10 01 0A 00 04 08 ... 8D E9 -> 01 10 01 0A 00 04 E0 34), match calculation. Manual address = frame address (0-based)."},{"ko":"출하 프로토콜은 CompoWay/F — 통신 설정 레벨에서 psel 을 mod 로 바꾸고 리셋해야 Modbus 로 동작한다. 출하값: 국번 1, 9.6 kbps, 데이터 7비트, 정지 2비트, 짝수 패리티 (1-7 (PDF 21)). Modbus 는 데이터 8비트여야 하므로 len 을 8 로 바꾼다.","en":"Factory protocol is CompoWay/F: set psel to mod in the communications setting level and reset. Defaults: unit 1, 9.6 kbps, 7 data bits, 2 stop bits, even parity (1-7 (PDF 21)). Modbus requires 8 data bits, so set len to 8."},{"ko":"함수 코드 03·06·08·10. 2바이트 모드(이 표)는 한 번에 106개 읽기·104개 쓰기. 4바이트 모드는 0000h~ 의 다른 주소(값 하나 = 2워드)를 쓴다. 파라미터를 쓰려면 먼저 «통신 쓰기» 를 ON(운전 명령 0001h)으로.","en":"Function codes 03, 06, 08, 10. Two-byte mode (this table): up to 106 read / 104 write per request. Four-byte mode uses different addresses from 0000h (two words per value). Turn Communications Writing ON first (operation command 0001h) to write parameters."}]},"notes":[{"ko":"값은 소수점 없는 정수다(예 100.0 → 1000). PV·SP·경보값의 소수점 자리는 입력 종류·소수점 설정을 따르므로 scale 을 넣지 않았다. 불감대·히스테리시스·대기 폭도 모델(열전대·측온 저항체 0.1, 아날로그 0.01)에 따라 배율이 달라 넣지 않았다.","en":"Values are integers without decimal point (e.g. 100.0 → 1000). PV, SP and alarm decimal places follow the input type / decimal point setting, so no scale is given. Dead band, hysteresis and wait band are also left out because their scale depends on the model (0.1 for TC/Pt, 0.01 for analog)."},{"ko":"RS-485 통신 기능이 있는 형번만 해당(E5AN·E5EN·E5GN 은 RS-232C 형번도 있음). 출력·경보·히터 전류 항목은 형번(옵션)에 따라 없을 수 있다. 고급형 E5CN-H 등은 다른 매뉴얼(H159).","en":"Only models with communications (E5AN/E5EN/E5GN also have RS-232C models). Output, alarm and heater current items depend on model options. Advanced types such as E5CN-H use a different manual (H159)."}],"registers":[{"table":"holding-registers","address":0,"manualAddress":"0000","type":"u16","name":{"ko":"운전 명령","en":"Operation command"},"access":"w","fc":[6],"values":[{"value":0,"ko":"통신 쓰기 OFF","en":"Communications writing OFF"},{"value":1,"ko":"통신 쓰기 ON","en":"Communications writing ON"},{"value":256,"ko":"RUN","en":"Run"},{"value":257,"ko":"STOP","en":"Stop"},{"value":512,"ko":"다단 SP 0","en":"Multi-SP set point 0"},{"value":513,"ko":"다단 SP 1","en":"Multi-SP set point 1"},{"value":514,"ko":"다단 SP 2","en":"Multi-SP set point 2"},{"value":515,"ko":"다단 SP 3","en":"Multi-SP set point 3"},{"value":768,"ko":"AT 취소","en":"AT cancel"},{"value":769,"ko":"100% AT 실행","en":"100% AT execute"},{"value":770,"ko":"40% AT 실행","en":"40% AT execute"},{"value":1024,"ko":"백업 모드(EEPROM 에도 씀)","en":"Backup mode (also writes EEPROM)"},{"value":1025,"ko":"RAM 쓰기 모드","en":"RAM write mode"},{"value":1280,"ko":"RAM 데이터 저장","en":"Save RAM data"},{"value":1536,"ko":"소프트웨어 리셋","en":"Software reset"},{"value":1792,"ko":"설정 영역 1 로 이동","en":"Move to setup area 1"},{"value":2048,"ko":"보호 레벨로 이동","en":"Move to protect level"},{"value":2304,"ko":"자동 모드","en":"Automatic mode"},{"value":2305,"ko":"수동 모드","en":"Manual mode"},{"value":2816,"ko":"파라미터 초기화","en":"Parameter initialization"},{"value":3072,"ko":"경보 1 래치 해제","en":"Alarm 1 latch cancel"},{"value":3073,"ko":"경보 2 래치 해제","en":"Alarm 2 latch cancel"},{"value":3074,"ko":"경보 3 래치 해제","en":"Alarm 3 latch cancel"},{"value":3075,"ko":"HB 경보 래치 해제","en":"HB alarm latch cancel"},{"value":3076,"ko":"HS 경보 래치 해제","en":"HS alarm latch cancel"},{"value":3077,"ko":"OC 경보 래치 해제","en":"OC alarm latch cancel"},{"value":3087,"ko":"모든 경보 래치 해제","en":"All alarm latch cancel"},{"value":3584,"ko":"정·역동작 반전 안 함","en":"Direct/reverse not inverted"},{"value":3585,"ko":"정·역동작 반전","en":"Direct/reverse inverted"},{"value":4352,"ko":"프로그램 리셋","en":"Program reset"},{"value":4353,"ko":"프로그램 시작","en":"Program start"}],"description":{"ko":"FC06 전용(주소 0000 또는 FFFF). 쓰기 값 = 명령 코드(상위 바이트) + 관련 정보(하위 바이트). 매뉴얼 예: 01 06 00 00 01 01 49 9A(STOP). 명령은 통신 쓰기 설정과 관계없이 받는다","en":"FC06 only (address 0000 or FFFF). Write value = command code (high byte) + related information (low byte). Manual example: 01 06 00 00 01 01 49 9A (stop). Accepted regardless of the Communications Writing setting"},"ref":"5-14~5-16 (PDF 94-96)","source":0},{"table":"holding-registers","address":8192,"manualAddress":"2000","type":"s16","name":{"ko":"PV(현재값)","en":"PV (process value)"},"access":"r","fc":[3],"description":{"ko":"소수점 없는 정수, 예 100.0 ℃ = 03E8h(매뉴얼 읽기 예)","en":"Integer without decimal point, e.g. 100.0 °C = 03E8h (manual read example)"},"ref":"6-2 (PDF 104)","source":0},{"table":"holding-registers","address":8193,"manualAddress":"2001","type":"u16","name":{"ko":"상태(하위 16비트)","en":"Status (lower 16 bits)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"히터 과전류(CT1)","en":"Heater overcurrent (CT1)"},{"bit":1,"ko":"히터 전류 유지(CT1)","en":"Heater current hold (CT1)"},{"bit":2,"ko":"A/D 변환기 오류","en":"A/D converter error"},{"bit":3,"ko":"HS 경보(CT1)","en":"HS alarm (CT1)"},{"bit":5,"ko":"표시 범위 초과","en":"Display range exceeded"},{"bit":6,"ko":"입력 오류","en":"Input error"},{"bit":8,"ko":"제어 출력(가열)","en":"Control output (heating)"},{"bit":9,"ko":"제어 출력(냉각)","en":"Control output (cooling)"},{"bit":10,"ko":"HB 경보(CT1)","en":"HB (heater burnout) alarm (CT1)"},{"bit":11,"ko":"HB 경보(CT2)","en":"HB (heater burnout) alarm (CT2)"},{"bit":12,"ko":"경보 1","en":"Alarm 1"},{"bit":13,"ko":"경보 2","en":"Alarm 2"},{"bit":14,"ko":"경보 3","en":"Alarm 3"},{"bit":15,"ko":"프로그램 종료 출력","en":"Program end output"}],"description":{"ko":"1 = 발생/ON","en":"1 = generated/ON"},"ref":"6-2, 6-20 (PDF 104, 122)","source":0},{"table":"holding-registers","address":8194,"manualAddress":"2002","type":"s16","name":{"ko":"내부 SP","en":"Internal set point"},"access":"r","fc":[3],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410 (decimal point monitor) / input type"},"ref":"6-2 (PDF 104)","source":0},{"table":"holding-registers","address":8195,"manualAddress":"2003","type":"u16","name":{"ko":"히터 전류 1 모니터","en":"Heater current 1 value monitor"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":55},"ref":"6-2 (PDF 104)","source":0},{"table":"holding-registers","address":8196,"manualAddress":"2004","type":"s16","name":{"ko":"MV 모니터(가열)","en":"MV monitor (heating)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"표준 −5.0~105.0, 가열·냉각 0.0~105.0","en":"Standard -5.0 to 105.0, heating/cooling 0.0 to 105.0"},"ref":"6-2 (PDF 104)","source":0},{"table":"holding-registers","address":8197,"manualAddress":"2005","type":"u16","name":{"ko":"MV 모니터(냉각)","en":"MV monitor (cooling)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":105},"ref":"6-2 (PDF 104)","source":0},{"table":"holding-registers","address":8451,"manualAddress":"2103","type":"s16","name":{"ko":"SP(목표값)","en":"Set point"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410 (decimal point monitor) / input type"},"ref":"6-2 (PDF 104)","source":0},{"table":"holding-registers","address":8452,"manualAddress":"2104","type":"s16","name":{"ko":"경보값 1","en":"Alarm value 1"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~9999. 소수점은 입력 설정을 따른다","en":"-1999 to 9999. Decimal point follows the input setting"},"ref":"6-2~6-3 (PDF 104-105)","source":0},{"table":"holding-registers","address":8453,"manualAddress":"2105","type":"s16","name":{"ko":"경보 상한값 1","en":"Alarm value upper limit 1"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~9999. 소수점은 입력 설정을 따른다","en":"-1999 to 9999. Decimal point follows the input setting"},"ref":"6-2~6-3 (PDF 104-105)","source":0},{"table":"holding-registers","address":8454,"manualAddress":"2106","type":"s16","name":{"ko":"경보 하한값 1","en":"Alarm value lower limit 1"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~9999. 소수점은 입력 설정을 따른다","en":"-1999 to 9999. Decimal point follows the input setting"},"ref":"6-2~6-3 (PDF 104-105)","source":0},{"table":"holding-registers","address":8455,"manualAddress":"2107","type":"s16","name":{"ko":"경보값 2","en":"Alarm value 2"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~9999. 소수점은 입력 설정을 따른다","en":"-1999 to 9999. Decimal point follows the input setting"},"ref":"6-2~6-3 (PDF 104-105)","source":0},{"table":"holding-registers","address":8456,"manualAddress":"2108","type":"s16","name":{"ko":"경보 상한값 2","en":"Alarm value upper limit 2"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~9999. 소수점은 입력 설정을 따른다","en":"-1999 to 9999. Decimal point follows the input setting"},"ref":"6-2~6-3 (PDF 104-105)","source":0},{"table":"holding-registers","address":8457,"manualAddress":"2109","type":"s16","name":{"ko":"경보 하한값 2","en":"Alarm value lower limit 2"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~9999. 소수점은 입력 설정을 따른다","en":"-1999 to 9999. Decimal point follows the input setting"},"ref":"6-2~6-3 (PDF 104-105)","source":0},{"table":"holding-registers","address":9220,"manualAddress":"2404","type":"u16","name":{"ko":"다단 SP 번호 모니터","en":"Multi-SP monitor"},"access":"r","fc":[3],"range":{"min":0,"max":3},"ref":"6-3 (PDF 105)","source":0},{"table":"holding-registers","address":9223,"manualAddress":"2407","type":"u16","name":{"ko":"상태(상위 16비트)","en":"Status (upper 16 bits)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"이벤트 입력 1","en":"Event input 1"},{"bit":1,"ko":"이벤트 입력 2","en":"Event input 2"},{"bit":2,"ko":"이벤트 입력 3","en":"Event input 3"},{"bit":3,"ko":"이벤트 입력 4","en":"Event input 4"},{"bit":4,"ko":"쓰기 모드(1 = RAM 쓰기)","en":"Write mode (1 = RAM write)"},{"bit":5,"ko":"EEPROM(1 = RAM ≠ EEPROM)","en":"EEPROM (1 = RAM ≠ EEPROM)"},{"bit":6,"ko":"설정 영역(1 = 영역 1)","en":"Setup area (1 = area 1)"},{"bit":7,"ko":"AT 실행 중","en":"AT execution in progress"},{"bit":8,"ko":"RUN/STOP(1 = STOP)","en":"RUN/STOP (1 = stop)"},{"bit":9,"ko":"통신 쓰기 ON","en":"Communications writing ON"},{"bit":10,"ko":"수동 모드","en":"Manual mode"},{"bit":11,"ko":"프로그램 시작","en":"Program start"},{"bit":12,"ko":"히터 과전류(CT2)","en":"Heater overcurrent (CT2)"},{"bit":13,"ko":"히터 전류 유지(CT2)","en":"Heater current hold (CT2)"},{"bit":15,"ko":"HS 경보(CT2)","en":"HS alarm (CT2)"}],"description":{"ko":"32비트 상태의 비트 16~31 을 비트 0~15 로 읽는다","en":"Bits 16-31 of the 32-bit status, read as bits 0-15"},"ref":"6-3, 6-20 (PDF 105, 122)","source":0},{"table":"holding-registers","address":9232,"manualAddress":"2410","type":"u16","name":{"ko":"소수점 모니터","en":"Decimal point monitor"},"access":"r","fc":[3],"range":{"min":0,"max":3},"description":{"ko":"소수점 아래 자릿수","en":"Number of decimal places"},"ref":"6-3 (PDF 105)","source":0},{"table":"holding-registers","address":9472,"manualAddress":"2500","type":"u16","name":{"ko":"운전/조정 보호","en":"Operation/adjustment protect"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"제한 없음","en":"No restrictions"},{"value":1,"ko":"조정 레벨 이동 금지","en":"Move to adjustment level prohibited"},{"value":2,"ko":"PV·PV/SP 만 표시·변경","en":"Only PV and PV/SP displayed and changeable"},{"value":3,"ko":"PV·PV/SP 만 표시","en":"Only PV and PV/SP displayed"}],"ref":"6-3 (PDF 105)","source":0},{"table":"holding-registers","address":9473,"manualAddress":"2501","type":"u16","name":{"ko":"초기 설정/통신 보호","en":"Initial setting/communications protect"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"이동 허용(고급 기능 표시)","en":"Move allowed (advanced function level displayed)"},{"value":1,"ko":"이동 허용(고급 기능 표시 안 함)","en":"Move allowed (advanced function level not displayed)"},{"value":2,"ko":"이동 금지","en":"Move prohibited"}],"ref":"6-3 (PDF 105)","source":0},{"table":"holding-registers","address":9474,"manualAddress":"2502","type":"u16","name":{"ko":"설정 변경 보호","en":"Setting change protect"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"OFF(앞면 변경 허용)","en":"OFF (changes on display allowed)"},{"value":1,"ko":"ON(앞면 변경 금지)","en":"ON (changes on display prohibited)"}],"ref":"6-3 (PDF 105)","source":0},{"table":"holding-registers","address":9728,"manualAddress":"2600","type":"s16","name":{"ko":"수동 MV","en":"Manual MV"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"표준 −5.0~105.0, 가열·냉각 −105.0~105.0","en":"Standard -5.0 to 105.0, heating/cooling -105.0 to 105.0"},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":9984,"manualAddress":"2700","type":"u16","name":{"ko":"냉각 계수","en":"Cooling coefficient"},"scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0.01,"max":99.99},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":9989,"manualAddress":"2705","type":"u16","name":{"ko":"수동 리셋값","en":"Manual reset value"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":9992,"manualAddress":"2708","type":"u16","name":{"ko":"제어 주기(가열)","en":"Control period (heating)"},"unit":"s","access":"rw","fc":[3,6,16],"description":{"ko":"0 = 0.5 s, 1~99 = 1~99 s. 초기 설정 레벨(설정 영역 1)","en":"0 = 0.5 s, 1-99 = 1-99 s. Initial setting level (setup area 1)"},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":9993,"manualAddress":"2709","type":"u16","name":{"ko":"제어 주기(냉각)","en":"Control period (cooling)"},"unit":"s","access":"rw","fc":[3,6,16],"description":{"ko":"0 = 0.5 s, 1~99 = 1~99 s. 초기 설정 레벨(설정 영역 1)","en":"0 = 0.5 s, 1-99 = 1-99 s. Initial setting level (setup area 1)"},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":10012,"manualAddress":"271C","type":"u16","name":{"ko":"누설 전류 1 모니터","en":"Leakage current 1 monitor"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":55},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":10020,"manualAddress":"2724","type":"u16","name":{"ko":"히터 전류 2 모니터","en":"Heater current 2 value monitor"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":55},"ref":"6-5 (PDF 107)","source":0},{"table":"holding-registers","address":10022,"manualAddress":"2726","type":"u16","name":{"ko":"누설 전류 2 모니터","en":"Leakage current 2 monitor"},"unit":"A","scale":0.1,"access":"r","fc":[3],"range":{"min":0,"max":55},"ref":"6-5 (PDF 107)","source":0},{"table":"holding-registers","address":10024,"manualAddress":"2728","type":"u16","name":{"ko":"소크 남은 시간","en":"Soak time remain"},"access":"r","fc":[3],"range":{"min":0,"max":9999},"ref":"6-5 (PDF 107)","source":0},{"table":"holding-registers","address":10011,"manualAddress":"271B","type":"u16","name":{"ko":"히터 단선 검출 1","en":"Heater burnout detection 1"},"unit":"A","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":50},"ref":"6-4 (PDF 106)","source":0},{"table":"holding-registers","address":10021,"manualAddress":"2725","type":"u16","name":{"ko":"히터 단선 검출 2","en":"Heater burnout detection 2"},"unit":"A","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":50},"ref":"6-5 (PDF 107)","source":0},{"table":"holding-registers","address":10496,"manualAddress":"2900","type":"s16","name":{"ko":"다단 SP 0","en":"Multi-SP SP 0"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410 (decimal point monitor) / input type"},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10510,"manualAddress":"290E","type":"s16","name":{"ko":"다단 SP 1","en":"Multi-SP SP 1"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410 (decimal point monitor) / input type"},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10524,"manualAddress":"291C","type":"s16","name":{"ko":"다단 SP 2","en":"Multi-SP SP 2"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410 (decimal point monitor) / input type"},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10538,"manualAddress":"292A","type":"s16","name":{"ko":"다단 SP 3","en":"Multi-SP SP 3"},"access":"rw","fc":[3,6,16],"description":{"ko":"소수점 없는 정수 — 소수점 자리는 2410(소수점 모니터)·입력 종류에 따른다","en":"Integer without decimal point; decimal places follow 2410 (decimal point monitor) / input type"},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10752,"manualAddress":"2A00","type":"u16","name":{"ko":"비례대","en":"Proportional band"},"scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":999.9},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10753,"manualAddress":"2A01","type":"u16","name":{"ko":"적분 시간","en":"Integral time"},"unit":"s","access":"rw","fc":[3,6,16],"range":{"min":0,"max":3999},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10754,"manualAddress":"2A02","type":"u16","name":{"ko":"미분 시간","en":"Derivative time"},"unit":"s","access":"rw","fc":[3,6,16],"description":{"ko":"RT OFF 이면 0~3999(1 s), RT ON 이면 0.0~999.9(0.1 s)","en":"0-3999 (1 s) with RT OFF, 0.0-999.9 (0.1 s) with RT ON"},"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10757,"manualAddress":"2A05","type":"s16","name":{"ko":"MV 상한","en":"MV upper limit"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":10758,"manualAddress":"2A06","type":"s16","name":{"ko":"MV 하한","en":"MV lower limit"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"ref":"6-6 (PDF 108)","source":0},{"table":"holding-registers","address":11264,"manualAddress":"2C00","type":"u16","name":{"ko":"입력 종류(열전대·측온 저항체 모델)","en":"Input type (TC/Pt multi-input models)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"Pt −200~850 ℃","en":"Pt -200 to 850 °C"},{"value":1,"ko":"Pt −199.9~500.0 ℃","en":"Pt -199.9 to 500.0 °C"},{"value":2,"ko":"Pt 0.0~100.0 ℃","en":"Pt 0.0 to 100.0 °C"},{"value":3,"ko":"JPt −199.9~500.0 ℃","en":"JPt -199.9 to 500.0 °C"},{"value":4,"ko":"JPt 0.0~100.0 ℃","en":"JPt 0.0 to 100.0 °C"},{"value":5,"ko":"K −200~1300 ℃","en":"K -200 to 1300 °C"},{"value":6,"ko":"K −20.0~500.0 ℃","en":"K -20.0 to 500.0 °C"},{"value":7,"ko":"J −100~850 ℃","en":"J -100 to 850 °C"},{"value":8,"ko":"J −20.0~400.0 ℃","en":"J -20.0 to 400.0 °C"},{"value":9,"ko":"T −200~400 ℃","en":"T -200 to 400 °C"},{"value":10,"ko":"T −199.9~400.0 ℃","en":"T -199.9 to 400.0 °C"},{"value":11,"ko":"E −200~600 ℃","en":"E -200 to 600 °C"},{"value":12,"ko":"L −100~850 ℃","en":"L -100 to 850 °C"},{"value":13,"ko":"U −200~400 ℃","en":"U -200 to 400 °C"},{"value":14,"ko":"U −199.9~400.0 ℃","en":"U -199.9 to 400.0 °C"},{"value":15,"ko":"N −200~1300 ℃","en":"N -200 to 1300 °C"},{"value":16,"ko":"R 0~1700 ℃","en":"R 0 to 1700 °C"},{"value":17,"ko":"S 0~1700 ℃","en":"S 0 to 1700 °C"},{"value":18,"ko":"B 100~1800 ℃","en":"B 100 to 1800 °C"},{"value":19,"ko":"적외선 센서 K 140 ℉/60 ℃","en":"Infrared sensor K 140 °F/60 °C"},{"value":20,"ko":"적외선 센서 K 240 ℉/120 ℃","en":"Infrared sensor K 240 °F/120 °C"},{"value":21,"ko":"적외선 센서 K 280 ℉/140 ℃","en":"Infrared sensor K 280 °F/140 °C"},{"value":22,"ko":"적외선 센서 K 440 ℉/220 ℃","en":"Infrared sensor K 440 °F/220 °C"},{"value":23,"ko":"0~50 mV","en":"0 to 50 mV"},{"value":24,"ko":"W 0~2300 ℃","en":"W 0 to 2300 °C"},{"value":25,"ko":"PL II 0~1300 ℃","en":"PL II 0 to 1300 °C"}],"description":{"ko":"아날로그 입력 모델은 0 = 4~20 mA, 1 = 0~20 mA, 2 = 1~5 V, 3 = 0~5 V, 4 = 0~10 V. 초기 설정 레벨 — 쓰려면 설정 영역 1 로 이동(운전 명령 0700h). ℉ 범위는 매뉴얼 표","en":"Analog input models: 0 = 4-20 mA, 1 = 0-20 mA, 2 = 1-5 V, 3 = 0-5 V, 4 = 0-10 V. Initial setting level: move to setup area 1 (operation command 0700h) to write. °F ranges in the manual table"},"ref":"6-7 (PDF 109)","source":0},{"table":"holding-registers","address":11265,"manualAddress":"2C01","type":"u16","name":{"ko":"온도 단위","en":"Temperature unit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"℃","en":"°C"},{"value":1,"ko":"℉","en":"°F"}],"ref":"6-7 (PDF 109)","source":0},{"table":"holding-registers","address":11273,"manualAddress":"2C09","type":"s16","name":{"ko":"스케일링 하한","en":"Scaling lower limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"−1999~스케일링 상한 −1(아날로그 입력)","en":"-1999 to scaling upper limit - 1 (analog input)"},"ref":"6-7 (PDF 109)","source":0},{"table":"holding-registers","address":11275,"manualAddress":"2C0B","type":"s16","name":{"ko":"스케일링 상한","en":"Scaling upper limit"},"access":"rw","fc":[3,6,16],"description":{"ko":"스케일링 하한 +1~9999(아날로그 입력)","en":"Scaling lower limit + 1 to 9999 (analog input)"},"ref":"6-7 (PDF 109)","source":0},{"table":"holding-registers","address":11276,"manualAddress":"2C0C","type":"u16","name":{"ko":"소수점","en":"Decimal point"},"access":"rw","fc":[3,6,16],"description":{"ko":"열전대·측온 저항체 모델 0~1, 아날로그 입력 모델 0~3","en":"0-1 for TC/Pt models, 0-3 for analog input models"},"ref":"6-7 (PDF 109)","source":0}],"sources":[{"title":"E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type","publisher":"OMRON Corporation","edition":{"ko":"Cat. No. H158-E1-02","en":"Cat. No. H158-E1-02"},"url":"https://files.omron.eu/downloads/latest/manual/en/h158_e5_n_communications_manual_en.pdf","pages":{"ko":"통신 설정 1-7 (PDF 21), Modbus 절차 5-1~5-19 (PDF 81-99), 변수 표 6-2~6-7 (PDF 104-109), 상태 6-17~6-20 (PDF 119-122)","en":"Communications settings 1-7 (PDF 21), Modbus procedure 5-1 to 5-19 (PDF 81-99), variable list 6-2 to 6-7 (PDF 104-109), status 6-17 to 6-20 (PDF 119-122)"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"omron/mx2","manufacturer":{"ko":"오므론","en":"OMRON"},"model":"MX2","models":["3G3MX2"],"kind":"inverter","title":{"ko":"오므론 MX2 인버터 (내장 RS-485 Modbus RTU)","en":"OMRON MX2 inverter (built-in RS-485 Modbus RTU)"},"summary":{"ko":"내장 RS-485 Modbus RTU. 코일 0001h~(운전·입력·상태), 보유 레지스터 0001h~(지령·트립 이력), 1001h~(d 모니터), 1103h~(F·A·C 파라미터). 매뉴얼 번호 − 1 = 프레임 주소","en":"Built-in RS-485 Modbus RTU. Coils from 0001h (run, inputs, status), holding registers from 0001h (commands, trip history), 1001h (d monitors), 1103h (F/A/C parameters). Manual number - 1 = frame address"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[2400,4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":1,"unitRange":[1,247],"maxRegisters":16,"order":"ABCD","addressing":"one","notes":[{"ko":"주소 체계: 매뉴얼의 코일·레지스터 번호는 1 기준이고 «프레임 주소는 번호보다 1 작다» (p.302~309 주석). 예: 코일 읽기(p.302) 08 01 00 06 00 05 1C 91 → 코일 0007h~(입력 [1]~), 코일 쓰기(p.304) 08 05 00 00 FF 00 8C A3 → 코일 0001h(운전 지령), 레지스터 읽기(p.303) 01 03 00 11 00 06 95 CD → 0012h(트립 모니터 1 요인)~, FC17 예(p.309) 01 17 10 00 00 02 00 00 00 02 04 00 00 13 88 F4 86 → 1001h(d001) 읽기·0001h(F001)에 5000 쓰기. 이 프레임과 코일 읽기 응답(08 01 01 05 92 17)·코일 여러 개 쓰기(08 0F 00 06 00 05 02 17 00 83 EA, 응답 … 75 50)·FC17 응답(01 17 04 00 00 13 88 F4 71)의 CRC 는 계산값과 같다. 레지스터 읽기 응답의 CRC 는 AF 6D 로 적혀 있으나 계산값은 B4 7A — 주소와는 무관.","en":"Addressing: coil and register numbers in the manual are 1-based and «the address on the Modbus line is 1 less than the number» (notes, pp.302-309). Examples: read coils (p.302) 08 01 00 06 00 05 1C 91 → coils from 0007h (input [1]); write coil (p.304) 08 05 00 00 FF 00 8C A3 → coil 0001h (run command); read registers (p.303) 01 03 00 11 00 06 95 CD → from 0012h (fault monitor 1 factor); FC17 (p.309) 01 17 10 00 00 02 00 00 00 02 04 00 00 13 88 F4 86 → read 1001h (d001), write 5000 to 0001h (F001). CRCs of these frames and of the coil read response (08 01 01 05 92 17), write coils (08 0F 00 06 00 05 02 17 00 83 EA, response ... 75 50) and FC17 response (01 17 04 00 00 13 88 F4 71) match calculation. The register read response CRC is printed AF 6D but computes to B4 7A; this does not affect addressing."},{"ko":"함수 코드 01h·03h·05h·06h·08h·0Fh·10h·17h(읽기·쓰기 함께). 레지스터는 한 번에 16개, 코일은 32개까지 (p.299). 02h·04h 없음 — 읽기 전용 상태도 코일(01h)로 읽는다.","en":"Function codes 01h, 03h, 05h, 06h, 08h, 0Fh, 10h and 17h (read/write). Up to 16 registers or 32 coils per message (p.299). No 02h/04h; read-only status is read as coils (01h)."},{"ko":"출하값: C071 05 = 9600 bps, C072 국번 1, C074 00 = 패리티 없음, C075 1 = 정지 1비트 (p.366). 바꾼 뒤 전원을 다시 넣거나 RS 단자를 켰다 끈다 (p.297). 종단 200 Ω 은 DIP 스위치로 (p.296).","en":"Defaults: C071 05 = 9600 bps, C072 station 1, C074 00 = no parity, C075 1 = 1 stop bit (p.366). After changing, cycle power or toggle the RS terminal (p.297). The 200 Ω termination is set by DIP switch (p.296)."},{"ko":"32비트 값은 (high) 번호가 앞, (low) 번호가 뒤 — 상위 워드 먼저(ABCD). P400(빅/리틀 엔디언 선택)은 자유 매핑(P200 = 01)에 쓰는 값.","en":"32-bit values have the (high) number first and the (low) number next, i.e. high word first (ABCD). P400 (big/little endian) applies to free mapping (P200 = 01)."}]},"notes":[{"ko":"쪽 번호는 인쇄 쪽(PDF 쪽 = 인쇄 + 26).","en":"Page numbers are printed pages (PDF page = printed + 26)."},{"ko":"통신으로 운전·주파수를 주려면 A002 = 03, A001 = 03 (p.297).","en":"To run and set frequency by communication set A002 = 03 and A001 = 03 (p.297)."},{"ko":"트립 모니터의 주파수(0014h·0015h)·전류(0016h)는 넣지 않았다 — 표(p.319)는 0.01 Hz 32비트·0.01 A 인데, 같은 매뉴얼의 읽기 예(p.303)는 0014h = 0063h 를 9.9 Hz(0.1 Hz 단위, 상위 워드 자리), 0016h = 001Eh 를 3.0 A(0.1 A 단위)로 적어 어긋난다. 같은 이유로 트립 2~6 의 주파수·전류도 뺐다.","en":"Fault monitor frequency (0014h/0015h) and current (0016h) are not included: the table (p.319) gives 32-bit 0.01 Hz and 0.01 A, but the read example in the same manual (p.303) shows 0014h = 0063h as 9.9 Hz (0.1 Hz units, in the high word) and 0016h = 001Eh as 3.0 A (0.1 A units). Frequency and current of trips 2-6 are left out for the same reason."},{"ko":"가속 시간 1(F002)은 넣지 않았다 — 표(p.324)는 1103h·1104h 인데 FC10 예(p.308)는 «1014h·1015h» 에 쓴다(프레임 10 13). 다단속 0(A020)도 표(p.324)는 1216h·1217h, 0.01 Hz 인데 FC06 예(p.305)는 «1029h», 0.1 Hz 로 적어 뺐다. 출력 전류 1003h(d002)는 한 칸(16비트)인데 범위가 0~999900 이라 넣지 않았다.","en":"Acceleration time 1 (F002) is not included: the table (p.324) gives 1103h/1104h but the FC10 example (p.308) writes «1014h/1015h» (frame 10 13). Multi-speed 0 (A020) is also left out: the table (p.324) gives 1216h/1217h at 0.01 Hz but the FC06 example (p.305) says «1029h» at 0.1 Hz. Output current 1003h (d002) is a single 16-bit register with a range of 0-999900, so it is left out."},{"ko":"통신으로 쓴 값은 RAM 에만 있다. 남기려면 0900h 에 1 을 쓰거나(ENTER), 쓰기 바로 전에 0902h 에 1 을 쓴다 (p.311).","en":"Values written by communication are in RAM only. To keep them write 1 to 0900h (ENTER), or write 1 to 0902h just before a write (p.311)."}],"registers":[{"table":"coils","address":0,"manualAddress":"0001h","type":"bit","name":{"ko":"운전 지령","en":"Operation command"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 운전, 0 = 정지. A002 = 03 일 때 유효","en":"1 = run, 0 = stop. Valid when A002 = 03"},"ref":"p.316","source":0},{"table":"coils","address":1,"manualAddress":"0002h","type":"bit","name":{"ko":"회전 방향 지령","en":"Rotation direction command"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 역회전, 0 = 정회전. A002 = 03 일 때 유효","en":"1 = reverse, 0 = forward. Valid when A002 = 03"},"ref":"p.316","source":0},{"table":"coils","address":2,"manualAddress":"0003h","type":"bit","name":{"ko":"외부 트립(EXT)","en":"External trip (EXT)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 트립","en":"1 = trip"},"ref":"p.316","source":0},{"table":"coils","address":3,"manualAddress":"0004h","type":"bit","name":{"ko":"트립 리셋(RS)","en":"Trip reset (RS)"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = 리셋","en":"1 = reset"},"ref":"p.316","source":0},{"table":"coils","address":6,"manualAddress":"0007h","type":"bit","name":{"ko":"다기능 입력 단자 [1]","en":"Intelligent input terminal [1]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":7,"manualAddress":"0008h","type":"bit","name":{"ko":"다기능 입력 단자 [2]","en":"Intelligent input terminal [2]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":8,"manualAddress":"0009h","type":"bit","name":{"ko":"다기능 입력 단자 [3]","en":"Intelligent input terminal [3]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":9,"manualAddress":"000Ah","type":"bit","name":{"ko":"다기능 입력 단자 [4]","en":"Intelligent input terminal [4]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":10,"manualAddress":"000Bh","type":"bit","name":{"ko":"다기능 입력 단자 [5]","en":"Intelligent input terminal [5]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":11,"manualAddress":"000Ch","type":"bit","name":{"ko":"다기능 입력 단자 [6]","en":"Intelligent input terminal [6]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":12,"manualAddress":"000Dh","type":"bit","name":{"ko":"다기능 입력 단자 [7]","en":"Intelligent input terminal [7]"},"access":"rw","fc":[1,5,15],"description":{"ko":"1 = ON. 제어 단자대의 입력이 코일보다 우선","en":"1 = ON. The terminal block input has priority over the coil"},"ref":"p.316","source":0},{"table":"coils","address":14,"manualAddress":"000Fh","type":"bit","name":{"ko":"운전 상태","en":"Operation status"},"access":"r","fc":[1],"description":{"ko":"1 = 운전, 0 = 정지(d003 와 연동)","en":"1 = run, 0 = stop (interlocked to d003)"},"ref":"p.316","source":0},{"table":"coils","address":15,"manualAddress":"0010h","type":"bit","name":{"ko":"회전 방향","en":"Rotation direction"},"access":"r","fc":[1],"description":{"ko":"1 = 역회전, 0 = 정회전(d003 와 연동)","en":"1 = reverse, 0 = forward (interlocked to d003)"},"ref":"p.316","source":0},{"table":"coils","address":16,"manualAddress":"0011h","type":"bit","name":{"ko":"인버터 준비","en":"Inverter ready"},"access":"r","fc":[1],"description":{"ko":"1 = 준비, 0 = 준비 안 됨","en":"1 = ready, 0 = not ready"},"ref":"p.316","source":0},{"table":"coils","address":18,"manualAddress":"0013h","type":"bit","name":{"ko":"RUN(운전 중)","en":"RUN (running)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":19,"manualAddress":"0014h","type":"bit","name":{"ko":"FA1(정속 도달)","en":"FA1 (constant-speed reached)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":20,"manualAddress":"0015h","type":"bit","name":{"ko":"FA2(설정 주파수 이상)","en":"FA2 (set frequency overreached)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":21,"manualAddress":"0016h","type":"bit","name":{"ko":"OL(과부하 예고 1)","en":"OL (overload advance notice 1)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":23,"manualAddress":"0018h","type":"bit","name":{"ko":"AL(알람 신호)","en":"AL (alarm signal)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":25,"manualAddress":"001Ah","type":"bit","name":{"ko":"OTQ(과토크)","en":"OTQ (over-torque)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":27,"manualAddress":"001Ch","type":"bit","name":{"ko":"UV(저전압)","en":"UV (undervoltage)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":39,"manualAddress":"0028h","type":"bit","name":{"ko":"ZS(0 Hz 검출)","en":"ZS (0 Hz detection signal)"},"access":"r","fc":[1],"ref":"p.316","source":0},{"table":"coils","address":57,"manualAddress":"003Ah","type":"bit","name":{"ko":"WAC(콘덴서 수명 경고)","en":"WAC (capacitor life warning)"},"access":"r","fc":[1],"ref":"p.317","source":0},{"table":"coils","address":58,"manualAddress":"003Bh","type":"bit","name":{"ko":"WAF(냉각팬 속도 저하)","en":"WAF (cooling-fan speed drop)"},"access":"r","fc":[1],"ref":"p.317","source":0},{"table":"coils","address":68,"manualAddress":"0045h","type":"bit","name":{"ko":"IRDY(인버터 준비)","en":"IRDY (inverter ready)"},"access":"r","fc":[1],"ref":"p.317","source":0},{"table":"coils","address":69,"manualAddress":"0046h","type":"bit","name":{"ko":"FWR(정회전 중)","en":"FWR (forward rotation)"},"access":"r","fc":[1],"ref":"p.317","source":0},{"table":"coils","address":70,"manualAddress":"0047h","type":"bit","name":{"ko":"RVR(역회전 중)","en":"RVR (reverse rotation)"},"access":"r","fc":[1],"ref":"p.317","source":0},{"table":"coils","address":71,"manualAddress":"0048h","type":"bit","name":{"ko":"MJA(중고장)","en":"MJA (major failure)"},"access":"r","fc":[1],"ref":"p.317","source":0},{"table":"coils","address":72,"manualAddress":"0049h","type":"bit","name":{"ko":"데이터 쓰는 중","en":"Data writing in progress"},"access":"r","fc":[1],"description":{"ko":"1 = 쓰는 중(ENTER 진행 확인용), 0 = 정상","en":"1 = writing in progress (use to watch ENTER), 0 = normal"},"ref":"p.317, p.311","source":0},{"table":"coils","address":73,"manualAddress":"004Ah","type":"bit","name":{"ko":"CRC 오류","en":"CRC error"},"access":"r","fc":[1],"description":{"ko":"1 = 오류 검출. 오류 리셋 지령까지 남는다","en":"1 = error detected. Kept until an error reset command"},"ref":"p.317","source":0},{"table":"coils","address":74,"manualAddress":"004Bh","type":"bit","name":{"ko":"오버런","en":"Overrun"},"access":"r","fc":[1],"description":{"ko":"1 = 오류 검출. 오류 리셋 지령까지 남는다","en":"1 = error detected. Kept until an error reset command"},"ref":"p.317","source":0},{"table":"coils","address":75,"manualAddress":"004Ch","type":"bit","name":{"ko":"프레이밍 오류","en":"Framing error"},"access":"r","fc":[1],"description":{"ko":"1 = 오류 검출. 오류 리셋 지령까지 남는다","en":"1 = error detected. Kept until an error reset command"},"ref":"p.317","source":0},{"table":"coils","address":76,"manualAddress":"004Dh","type":"bit","name":{"ko":"패리티 오류","en":"Parity error"},"access":"r","fc":[1],"description":{"ko":"1 = 오류 검출. 오류 리셋 지령까지 남는다","en":"1 = error detected. Kept until an error reset command"},"ref":"p.317","source":0},{"table":"coils","address":77,"manualAddress":"004Eh","type":"bit","name":{"ko":"합계 검사 오류","en":"Sum check error"},"access":"r","fc":[1],"description":{"ko":"1 = 오류 검출. 오류 리셋 지령까지 남는다","en":"1 = error detected. Kept until an error reset command"},"ref":"p.317","source":0},{"table":"coils","address":83,"manualAddress":"0054h","type":"bit","name":{"ko":"FREF(주파수 지령 소스)","en":"FREF (FQ command source)"},"access":"r","fc":[1],"description":{"ko":"1 = 오퍼레이터, 0 = 그 밖","en":"1 = operator, 0 = others"},"ref":"p.317","source":0},{"table":"coils","address":84,"manualAddress":"0055h","type":"bit","name":{"ko":"REF(운전 지령 소스)","en":"REF (RUN command source)"},"access":"r","fc":[1],"description":{"ko":"1 = 오퍼레이터, 0 = 그 밖","en":"1 = operator, 0 = others"},"ref":"p.317","source":0},{"table":"holding-registers","address":0,"manualAddress":"0001h","type":"u32","order":"ABCD","name":{"ko":"출력 주파수 설정/모니터(F001)","en":"Output frequency setting/monitor (F001)"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0,"max":400},"description":{"ko":"0001h 상위·0002h 하위. 쓰기는 A001 = 03 일 때 유효. FC17 예(p.309)가 시작 00 00 에 00 00 13 88(50.00 Hz)을 쓴다","en":"0001h high, 0002h low. Writing is valid when A001 = 03. The FC17 example (p.309) writes 00 00 13 88 (50.00 Hz) at start 00 00"},"ref":"p.318, p.309","source":0},{"table":"holding-registers","address":2,"manualAddress":"0003h","type":"u16","name":{"ko":"인버터 상태 A","en":"Inverter status A"},"access":"r","fc":[3],"values":[{"value":0,"ko":"초기 상태","en":"Initial status"},{"value":2,"ko":"정지 중","en":"Stopping"},{"value":3,"ko":"운전 중","en":"Running"},{"value":4,"ko":"프리런 정지","en":"Free-run stop"},{"value":5,"ko":"조그","en":"Jogging"},{"value":6,"ko":"직류 제동","en":"DC braking"},{"value":7,"ko":"재시도","en":"Retrying"},{"value":8,"ko":"트립","en":"Tripping"},{"value":9,"ko":"저전압(UV)","en":"Undervoltage (UV)"}],"ref":"p.318","source":0},{"table":"holding-registers","address":3,"manualAddress":"0004h","type":"u16","name":{"ko":"인버터 상태 B","en":"Inverter status B"},"access":"r","fc":[3],"values":[{"value":0,"ko":"정지 중","en":"Stopping"},{"value":1,"ko":"운전 중","en":"Running"},{"value":2,"ko":"트립","en":"Tripping"}],"ref":"p.318","source":0},{"table":"holding-registers","address":4,"manualAddress":"0005h","type":"u16","name":{"ko":"인버터 상태 C","en":"Inverter status C"},"access":"r","fc":[3],"values":[{"value":1,"ko":"정지 중","en":"Stopping"},{"value":2,"ko":"감속 중","en":"Decelerating"},{"value":3,"ko":"정속 운전","en":"Constant-speed operation"},{"value":4,"ko":"가속 중","en":"Accelerating"},{"value":5,"ko":"정회전","en":"Forward rotation"},{"value":6,"ko":"역회전","en":"Reverse rotation"},{"value":7,"ko":"정→역 전환 중","en":"Switching from forward to reverse"},{"value":8,"ko":"역→정 전환 중","en":"Switching from reverse to forward"},{"value":9,"ko":"정회전 시동","en":"Starting forward"},{"value":10,"ko":"역회전 시동","en":"Starting reverse"}],"ref":"p.318","source":0},{"table":"holding-registers","address":5,"manualAddress":"0006h","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.01,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.318","source":0},{"table":"holding-registers","address":16,"manualAddress":"0011h","type":"u16","name":{"ko":"트립 횟수(d080)","en":"Fault frequency monitor (d080)"},"access":"r","fc":[3],"description":{"ko":"트립이 일어난 횟수 0~65535","en":"Number of trips 0-65535"},"ref":"p.319","source":0},{"table":"holding-registers","address":17,"manualAddress":"0012h","type":"u16","name":{"ko":"트립 모니터 1 요인(d081)","en":"Fault monitor 1 factor (d081)"},"access":"r","fc":[3],"values":[{"value":0,"ko":"트립 없음","en":"No trip factor"},{"value":1,"ko":"정속 중 과전류","en":"Over-current at constant speed"},{"value":2,"ko":"감속 중 과전류","en":"Over-current during deceleration"},{"value":3,"ko":"가속 중 과전류","en":"Over-current during acceleration"},{"value":4,"ko":"그 밖의 과전류","en":"Over-current during other conditions"},{"value":5,"ko":"과부하 보호","en":"Overload protection"},{"value":6,"ko":"제동 저항 과부하","en":"Braking resistor overload protection"},{"value":7,"ko":"과전압 보호","en":"Overvoltage protection"},{"value":8,"ko":"EEPROM 오류","en":"EEPROM error"},{"value":9,"ko":"저전압 보호","en":"Undervoltage protection"},{"value":10,"ko":"전류 검출 오류","en":"Current detection error"},{"value":11,"ko":"CPU 오류","en":"CPU error"},{"value":12,"ko":"외부 트립","en":"External trip"},{"value":13,"ko":"USP 오류","en":"USP error"},{"value":14,"ko":"지락 보호","en":"Ground-fault protection"},{"value":15,"ko":"입력 과전압 보호","en":"Input overvoltage protection"},{"value":21,"ko":"인버터 열 트립","en":"Inverter thermal trip"},{"value":22,"ko":"CPU 오류","en":"CPU error"},{"value":25,"ko":"주회로 오류","en":"Main circuit error"},{"value":30,"ko":"드라이버 오류","en":"Driver error"},{"value":35,"ko":"서미스터 오류","en":"Thermistor error"},{"value":36,"ko":"제동 오류","en":"Braking error"},{"value":37,"ko":"안전 정지","en":"Safe Stop"},{"value":38,"ko":"저속 과부하 보호","en":"Low-speed overload protection"},{"value":40,"ko":"오퍼레이터 연결","en":"Operator connection"},{"value":41,"ko":"Modbus 통신 오류","en":"Modbus communication error"},{"value":43,"ko":"EzSQ 오류(잘못된 명령)","en":"Easy sequence error (invalid instruction)"},{"value":44,"ko":"EzSQ 오류(중첩 횟수)","en":"Easy sequence error (invalid nesting count)"},{"value":45,"ko":"EzSQ 실행 오류 1","en":"Easy sequence execution error 1"},{"value":80,"ko":"엔코더 단선","en":"Encoder disconnection"},{"value":81,"ko":"과속도","en":"Excessive speed"},{"value":83,"ko":"위치 제어 범위 트립","en":"Position control range trip"}],"description":{"ko":"가장 최근 트립. 50~59 = EzSQ 사용자 트립 0~9, 60~69 = 옵션 오류 0~9. 트립 2~6 은 001Ch·0026h·0030h·003Ah·0044h 부터 같은 꼴","en":"Latest trip. 50-59 = EzSQ user trip 0-9, 60-69 = option error 0-9. Trips 2-6 follow the same layout from 001Ch, 0026h, 0030h, 003Ah, 0044h"},"ref":"p.319, p.321","source":0},{"table":"holding-registers","address":18,"manualAddress":"0013h","type":"u16","name":{"ko":"트립 모니터 1 인버터 상태","en":"Fault monitor 1 inverter status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"리셋 중","en":"Resetting"},{"value":1,"ko":"정지 중","en":"Stopping"},{"value":2,"ko":"감속 중","en":"Decelerating"},{"value":3,"ko":"정속 운전","en":"Constant-speed operation"},{"value":4,"ko":"가속 중","en":"Accelerating"},{"value":5,"ko":"0 Hz 운전","en":"Operating at zero frequency"},{"value":6,"ko":"시동 중","en":"Starting"},{"value":7,"ko":"직류 제동","en":"DC braking"},{"value":8,"ko":"과부하 제한","en":"Overload restricted"}],"ref":"p.319, p.321","source":0},{"table":"holding-registers","address":22,"manualAddress":"0017h","type":"u16","name":{"ko":"트립 모니터 1 직류 전압","en":"Fault monitor 1 DC voltage"},"unit":"V","access":"r","fc":[3],"description":{"ko":"트립 때 직류 입력 전압","en":"DC input voltage at tripping"},"ref":"p.319","source":0},{"table":"holding-registers","address":23,"manualAddress":"0018h","type":"u32","order":"ABCD","name":{"ko":"트립 모니터 1 누적 운전 시간","en":"Fault monitor 1 cumulative running time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"트립 때 누적 운전 시간. 0018h 상위·0019h 하위","en":"Cumulative running time at tripping. 0018h high, 0019h low"},"ref":"p.319","source":0},{"table":"holding-registers","address":25,"manualAddress":"001Ah","type":"u32","order":"ABCD","name":{"ko":"트립 모니터 1 누적 전원 시간","en":"Fault monitor 1 cumulative power-on time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"트립 때 누적 전원 투입 시간. 001Ah 상위·001Bh 하위","en":"Cumulative power-on time at tripping. 001Ah high, 001Bh low"},"ref":"p.319","source":0},{"table":"holding-registers","address":77,"manualAddress":"004Eh","type":"u16","name":{"ko":"경고 코드(d090)","en":"Warning code (d090)"},"access":"r","fc":[3],"range":{"min":0,"max":385},"ref":"p.320","source":0},{"table":"holding-registers","address":2303,"manualAddress":"0900h","type":"u16","name":{"ko":"EEPROM 쓰기(ENTER)","en":"Writing to EEPROM (ENTER)"},"access":"w","fc":[6,16],"values":[{"value":0,"ko":"모터 상수 재계산","en":"Motor constant recalculation"},{"value":1,"ko":"모든 데이터를 EEPROM 에 저장","en":"Save all data in EEPROM"}],"description":{"ko":"그 밖의 값 = 모터 상수 재계산 + 저장. 통신으로 쓴 값은 RAM 에만 있어 전원을 끄면 사라진다. 진행은 코일 0049h 로 본다. EEPROM 수명 약 10만 회","en":"Other values = recalculation and save. Values written by communication stay in RAM and are lost at power off. Watch coil 0049h for progress. EEPROM life about 100,000 writes"},"ref":"p.320, p.311","source":0},{"table":"holding-registers","address":2305,"manualAddress":"0902h","type":"u16","name":{"ko":"EEPROM 쓰기 모드","en":"EEPROM write mode"},"access":"w","fc":[6,16],"values":[{"value":0,"ko":"무효","en":"Invalid"},{"value":1,"ko":"유효","en":"Valid"}],"description":{"ko":"1 을 쓰면 바로 다음 06h 쓰기 한 번만 RAM·EEPROM 에 함께 쓴다","en":"Writing 1 makes only the next 06h write go to both RAM and EEPROM"},"ref":"p.320, p.311","source":0},{"table":"holding-registers","address":4096,"manualAddress":"1001h","type":"u32","order":"ABCD","name":{"ko":"출력 주파수 모니터(d001)","en":"Output frequency monitor (d001)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"1001h 상위·1002h 하위","en":"1001h high, 1002h low"},"ref":"p.322","source":0},{"table":"holding-registers","address":4099,"manualAddress":"1004h","type":"u16","name":{"ko":"회전 방향 모니터(d003)","en":"Rotation direction monitor (d003)"},"access":"r","fc":[3],"values":[{"value":0,"ko":"정지","en":"Stopping"},{"value":1,"ko":"정회전","en":"Forward rotation"},{"value":2,"ko":"역회전","en":"Reverse rotation"}],"ref":"p.322","source":0},{"table":"holding-registers","address":4102,"manualAddress":"1007h","type":"u16","name":{"ko":"다기능 입력 모니터(d005)","en":"Multi-function input monitor (d005)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"단자 1","en":"Terminal 1"},{"bit":1,"ko":"단자 2","en":"Terminal 2"},{"bit":2,"ko":"단자 3","en":"Terminal 3"},{"bit":3,"ko":"단자 4","en":"Terminal 4"},{"bit":4,"ko":"단자 5","en":"Terminal 5"},{"bit":5,"ko":"단자 6","en":"Terminal 6"},{"bit":6,"ko":"단자 7","en":"Terminal 7"}],"ref":"p.322","source":0},{"table":"holding-registers","address":4103,"manualAddress":"1008h","type":"u16","name":{"ko":"다기능 출력 모니터(d006)","en":"Multi-function output monitor (d006)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"단자 11","en":"Terminal 11"},{"bit":1,"ko":"단자 12","en":"Terminal 12"},{"bit":2,"ko":"릴레이 단자","en":"Relay terminal"}],"ref":"p.322","source":0},{"table":"holding-registers","address":4106,"manualAddress":"100Bh","type":"s32","order":"ABCD","name":{"ko":"실주파수 모니터(d008)","en":"Real frequency monitor (d008)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"100Bh 상위·100Ch 하위. -40000~+40000","en":"100Bh high, 100Ch low. -40000 to +40000"},"ref":"p.322","source":0},{"table":"holding-registers","address":4111,"manualAddress":"1010h","type":"s16","name":{"ko":"출력 토크 모니터(d012)","en":"Output torque monitor (d012)"},"unit":"%","access":"r","fc":[3],"description":{"ko":"-200~+200","en":"-200 to +200"},"ref":"p.322","source":0},{"table":"holding-registers","address":4112,"manualAddress":"1011h","type":"u16","name":{"ko":"출력 전압 모니터(d013)","en":"Output voltage monitor (d013)"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.322","source":0},{"table":"holding-registers","address":4113,"manualAddress":"1012h","type":"u16","name":{"ko":"입력 전력 모니터(d014)","en":"Input power monitor (d014)"},"unit":"kW","scale":0.1,"access":"r","fc":[3],"ref":"p.322","source":0},{"table":"holding-registers","address":4116,"manualAddress":"1015h","type":"u32","order":"ABCD","name":{"ko":"누적 운전 시간(d016)","en":"Total RUN time (d016)"},"unit":"h","access":"r","fc":[3],"description":{"ko":"1015h 상위·1016h 하위","en":"1015h high, 1016h low"},"ref":"p.322","source":0},{"table":"holding-registers","address":4118,"manualAddress":"1017h","type":"u32","order":"ABCD","name":{"ko":"누적 전원 시간(d017)","en":"Power ON time monitor (d017)"},"unit":"h","access":"r","fc":[3],"description":{"ko":"1017h 상위·1018h 하위","en":"1017h high, 1018h low"},"ref":"p.322","source":0},{"table":"holding-registers","address":4120,"manualAddress":"1019h","type":"s16","name":{"ko":"방열핀 온도(d018)","en":"Fin temperature monitor (d018)"},"unit":"°C","scale":0.1,"access":"r","fc":[3],"description":{"ko":"-200~1500(-20.0~150.0 °C)","en":"-200 to 1500 (-20.0 to 150.0 °C)"},"ref":"p.322","source":0},{"table":"holding-registers","address":4124,"manualAddress":"101Dh","type":"u16","name":{"ko":"수명 진단 모니터(d022)","en":"Life assessment monitor (d022)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"주회로 기판 콘덴서","en":"Capacitor on main circuit board"},{"bit":1,"ko":"냉각팬","en":"Cooling fan"}],"ref":"p.322","source":0},{"table":"holding-registers","address":4133,"manualAddress":"1026h","type":"u16","name":{"ko":"직류 전압 모니터(d102)","en":"DC voltage monitor (d102)"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.322","source":0},{"table":"holding-registers","address":4134,"manualAddress":"1027h","type":"u16","name":{"ko":"회생 제동 부하율(d103)","en":"Regenerative braking load rate (d103)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"ref":"p.322","source":0},{"table":"holding-registers","address":4135,"manualAddress":"1028h","type":"u16","name":{"ko":"전자 서멀 모니터(d104)","en":"Electronic thermal monitor (d104)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"100% 를 넘으면 E05 트립","en":"Trips E05 above 100%"},"ref":"p.322","source":0},{"table":"holding-registers","address":4182,"manualAddress":"1057h","type":"u16","name":{"ko":"인버터 모드(d060)","en":"Inverter mode (d060)"},"access":"r","fc":[3],"values":[{"value":0,"ko":"IM CT","en":"IM CT"},{"value":1,"ko":"IM VT","en":"IM VT"}],"ref":"p.322","source":0},{"table":"holding-registers","address":4184,"manualAddress":"1059h","type":"u16","name":{"ko":"주파수 지령 소스 모니터(d062)","en":"Frequency source monitor (d062)"},"access":"r","fc":[3],"values":[{"value":0,"ko":"오퍼레이터","en":"Operator"},{"value":1,"ko":"다단속 1","en":"Multi-speed 1"},{"value":2,"ko":"다단속 2","en":"Multi-speed 2"},{"value":3,"ko":"다단속 3","en":"Multi-speed 3"},{"value":4,"ko":"다단속 4","en":"Multi-speed 4"},{"value":5,"ko":"다단속 5","en":"Multi-speed 5"},{"value":6,"ko":"다단속 6","en":"Multi-speed 6"},{"value":7,"ko":"다단속 7","en":"Multi-speed 7"},{"value":8,"ko":"다단속 8","en":"Multi-speed 8"},{"value":9,"ko":"다단속 9","en":"Multi-speed 9"},{"value":10,"ko":"다단속 10","en":"Multi-speed 10"},{"value":11,"ko":"다단속 11","en":"Multi-speed 11"},{"value":12,"ko":"다단속 12","en":"Multi-speed 12"},{"value":13,"ko":"다단속 13","en":"Multi-speed 13"},{"value":14,"ko":"다단속 14","en":"Multi-speed 14"},{"value":15,"ko":"다단속 15","en":"Multi-speed 15"},{"value":16,"ko":"조그 주파수","en":"Jog frequency"},{"value":18,"ko":"Modbus","en":"Modbus network"},{"value":19,"ko":"옵션","en":"Option"},{"value":21,"ko":"볼륨","en":"Potentiometer"},{"value":22,"ko":"펄스열","en":"Pulse train"},{"value":23,"ko":"연산 기능 출력","en":"Calculated function output"},{"value":24,"ko":"EzSQ","en":"EzSQ (Drive Programming)"},{"value":25,"ko":"[O] 입력","en":"[O] input"},{"value":26,"ko":"[OI] 입력","en":"[OI] input"},{"value":27,"ko":"[O] + [OI]","en":"[O] + [OI]"}],"ref":"p.323","source":0},{"table":"holding-registers","address":4185,"manualAddress":"105Ah","type":"u16","name":{"ko":"운전 지령 소스 모니터(d063)","en":"Run source monitor (d063)"},"access":"r","fc":[3],"values":[{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터","en":"Operator"},{"value":3,"ko":"Modbus","en":"Modbus network"},{"value":4,"ko":"옵션","en":"Option"}],"ref":"p.323","source":0},{"table":"holding-registers","address":4256,"manualAddress":"10A1h","type":"u16","name":{"ko":"아날로그 입력 O 모니터(d130)","en":"Analog input O monitor (d130)"},"access":"r","fc":[3],"range":{"min":0,"max":1023},"ref":"p.323","source":0},{"table":"holding-registers","address":4257,"manualAddress":"10A2h","type":"u16","name":{"ko":"아날로그 입력 OI 모니터(d131)","en":"Analog input OI monitor (d131)"},"access":"r","fc":[3],"range":{"min":0,"max":1023},"ref":"p.323","source":0},{"table":"holding-registers","address":4356,"manualAddress":"1105h","type":"u32","order":"ABCD","name":{"ko":"감속 시간 1(F003)","en":"Deceleration time 1 (F003)"},"unit":"s","scale":0.01,"access":"rw","fc":[3,16],"range":{"min":0,"max":3600},"description":{"ko":"1105h 상위·1106h 하위","en":"1105h high, 1106h low"},"ref":"p.324","source":0},{"table":"holding-registers","address":4358,"manualAddress":"1107h","type":"u16","name":{"ko":"오퍼레이터 회전 방향(F004)","en":"Operator rotation direction (F004)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"정회전","en":"Forward"},{"value":1,"ko":"역회전","en":"Reverse"}],"ref":"p.324","source":0},{"table":"holding-registers","address":4608,"manualAddress":"1201h","type":"u16","name":{"ko":"주파수 지령 선택(A001)","en":"Frequency reference selection (A001)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"디지털 오퍼레이터","en":"Digital operator"},{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터","en":"Operator"},{"value":3,"ko":"Modbus 통신","en":"Modbus communication"},{"value":4,"ko":"옵션","en":"Option"},{"value":6,"ko":"펄스열 주파수","en":"Pulse train frequency"},{"value":7,"ko":"드라이브 프로그래밍","en":"Drive programming"},{"value":10,"ko":"연산 기능 결과","en":"Operation function result"}],"ref":"p.324","source":0},{"table":"holding-registers","address":4609,"manualAddress":"1202h","type":"u16","name":{"ko":"운전 지령 선택(A002)","en":"Run command selection (A002)"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"단자","en":"Terminal"},{"value":2,"ko":"오퍼레이터","en":"Operator"},{"value":3,"ko":"Modbus 통신","en":"Modbus communication"},{"value":4,"ko":"옵션","en":"Option"}],"description":{"ko":"바꾼 뒤 40 ms 이상 지나서 운전 지령을 준다","en":"Wait 40 ms or longer after changing before giving a run command"},"ref":"p.324","source":0},{"table":"holding-registers","address":4610,"manualAddress":"1203h","type":"u16","name":{"ko":"기저 주파수(A003)","en":"Base frequency (A003)"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"300~최고 주파수","en":"300 to maximum frequency"},"ref":"p.324","source":0},{"table":"holding-registers","address":4611,"manualAddress":"1204h","type":"u16","name":{"ko":"최고 주파수(A004)","en":"Maximum frequency (A004)"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":30,"max":400},"ref":"p.324","source":0},{"table":"holding-registers","address":5194,"manualAddress":"144Bh","type":"u16","name":{"ko":"통신 속도(C071)","en":"Communication speed (C071)"},"access":"rw","fc":[3,6,16],"values":[{"value":3,"ko":"2400 bps","en":"2400 bps"},{"value":4,"ko":"4800 bps","en":"4800 bps"},{"value":5,"ko":"9600 bps","en":"9600 bps"},{"value":6,"ko":"19.2 kbps","en":"19.2 kbps"},{"value":7,"ko":"38.4 kbps","en":"38.4 kbps"},{"value":8,"ko":"57.6 kbps","en":"57.6 kbps"},{"value":9,"ko":"76.8 kbps","en":"76.8 kbps"},{"value":10,"ko":"115.2 kbps","en":"115.2 kbps"}],"description":{"ko":"출하값 05. 바꾼 뒤 전원 재투입(또는 RS 단자 ON/OFF)","en":"Default 05. Reboot (or toggle the RS terminal) after changing"},"ref":"p.334, p.366","source":0},{"table":"holding-registers","address":5195,"manualAddress":"144Ch","type":"u16","name":{"ko":"국번(C072)","en":"Station number (C072)"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":247},"description":{"ko":"출하값 1","en":"Default 1"},"ref":"p.334, p.366","source":0},{"table":"holding-registers","address":5197,"manualAddress":"144Eh","type":"u16","name":{"ko":"패리티(C074)","en":"Parity (C074)"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"짝수","en":"Even"},{"value":2,"ko":"홀수","en":"Odd"}],"description":{"ko":"출하값 00","en":"Default 00"},"ref":"p.334, p.366","source":0},{"table":"holding-registers","address":5198,"manualAddress":"144Fh","type":"u16","name":{"ko":"정지 비트(C075)","en":"Stop bits (C075)"},"access":"rw","fc":[3,6,16],"values":[{"value":1,"ko":"1 비트","en":"1 bit"},{"value":2,"ko":"2 비트","en":"2 bits"}],"description":{"ko":"출하값 1","en":"Default 1"},"ref":"p.334, p.366","source":0}],"sources":[{"title":"OMRON MX2 User's Manual (Cat. No. I570-E2-02F)","publisher":"OMRON Corporation","edition":{"ko":"Cat. No. I570-E2-02F (개정 이력 02 = 2013년 1월, PDF 수정일 2022-09-09)","en":"Cat. No. I570-E2-02F (revision 02 = January 2013, PDF modified 2022-09-09)"},"url":"https://files.omron.eu/downloads/latest/manual/en/i570_mx2_users_manual_en.pdf","pages":{"ko":"부록 B Modbus 통신 인쇄 p.295~334(PDF 321~360), 기본값 표 p.366, d 모니터 3장","en":"Appendix B Modbus communications printed pp.295-334 (PDF 321-360), defaults p.366, d monitors chapter 3"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"rootech/accura-2300","manufacturer":{"ko":"루텍","en":"Rootech"},"model":"Accura 2300[S]","models":["Accura 2300","Accura 2300S","Accura 2350-3P"],"kind":"power-meter","title":{"ko":"루텍 Accura 2300[S] 전압 측정·통신 본체 + Accura 2350 전류 모듈","en":"Rootech Accura 2300[S] main unit with Accura 2350 current modules"},"summary":{"ko":"2300[S] 가 전압을 재고 내부 통신으로 붙은 Accura 2350 모듈(ID 0-39)의 전류·전력을 모아 Modbus TCP/RTU 로 내준다. 계측값은 PR(private read) — 11044 를 먼저 읽어 가져온 뒤 읽는다.","en":"The 2300[S] measures voltage and collects current/power from up to 40 Accura 2350 modules (ID 0-39), served over Modbus TCP/RTU. Measurement registers are private-read: read 11044 first to fetch."},"protocols":["rtu","tcp"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,115200],"parity":"even","stopBits":1,"tcpPort":502,"order":"ABCD","maxRegisters":125,"addressing":"one","notes":[{"ko":"매뉴얼은 레지스터 번호(1 기준) — 통신 주소 = 번호 − 1 (p.17, p.19, p.28).","en":"Manual uses 1-based register numbers; wire address = number − 1 (p.17, p.19, p.28)."},{"ko":"32비트는 상위 워드가 낮은 주소 (p.30 Data Types).","en":"32-bit values: high word at lower address (p.30 Data Types)."},{"ko":"RS-485 출하값 9600 bps·짝수·정지 1비트 (p.85). 국번 범위 0-247, Default 0 으로 적혀 있어 출하 국번은 비워 둠.","en":"RS-485 defaults 9600 bps, even, 1 stop bit (p.85). Address range 0-247 with 'Default: 0', so factory unit ID is left out."},{"ko":"Modbus TCP 포트 502 (p.14). TCP Unit ID 는 1 로 고정 (p.17). 동시 접속 16개(TCP 15, RTU 1) (p.18).","en":"Modbus TCP port 502 (p.14). TCP unit ID fixed at 1 (p.17). 16 concurrent connections (15 TCP, 1 RTU) (p.18)."},{"ko":"함수 코드 03·06·16 과 사용자 정의 101(65h, 멀티 블록 읽기, TCP 전용) (p.17). 읽기 수량 표준 1-125, 장치는 250 까지 허용하나 128 이상은 byte count 넘침 (p.19).","en":"FC 03, 06, 16 plus user-defined 101 (65h, multi-block read, TCP only) (p.17). Read quantity standard 1-125; device allows up to 250 but byte count overflows from 128 (p.19)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"1","type":"u16","name":{"ko":"제품 ID","en":"Product ID"},"access":"r","fc":[3],"description":{"ko":"2300","en":"2300"},"ref":"p.34 System Information for Accura 2300[S]"},{"table":"holding-registers","address":1,"manualAddress":"2","type":"u32","order":"ABCD","name":{"ko":"일련번호","en":"Serial number"},"access":"r","fc":[3],"ref":"p.34 System Information for Accura 2300[S]"},{"table":"holding-registers","address":14,"manualAddress":"15","type":"u16","name":{"ko":"응용 소프트웨어 버전","en":"Application version"},"access":"r","fc":[3],"ref":"p.34 System Information for Accura 2300[S]"},{"table":"holding-registers","address":16,"manualAddress":"17","type":"u16","name":{"ko":"Modbus 맵 버전","en":"Modbus map version"},"access":"r","fc":[3],"ref":"p.34 System Information for Accura 2300[S]"},{"table":"holding-registers","address":699,"manualAddress":"700","type":"u16","name":{"ko":"원격 설정 잠금","en":"Remote setup lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제","en":"Unlocked"},{"value":1,"ko":"잠금 (출하값)","en":"Locked (default)"}],"description":{"ko":"2300, 0, 700, 1 을 차례로 쓰면 해제. 접속마다 따로 해제해야 함","en":"Write 2300, 0, 700, 1 in sequence to unlock; per connection"},"ref":"p.38 Remote Setup Unlock"},{"table":"holding-registers","address":1483,"manualAddress":"1484","type":"u16","name":{"ko":"RS-485 국번","en":"RS-485 device address"},"access":"rw","fc":[3,6,16],"description":{"ko":"범위 0-247. 1483 접근 레지스터로 가져오기/적용(1 쓰기)","en":"Range 0-247. Fetch/apply via access register 1483 (write 1)"},"ref":"p.85 Modbus Serial Communication Setup"},{"table":"holding-registers","address":1484,"manualAddress":"1485","type":"u16","name":{"ko":"RS-485 통신 속도","en":"RS-485 baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200","en":"1200"},{"value":1,"ko":"2400","en":"2400"},{"value":2,"ko":"4800","en":"4800"},{"value":3,"ko":"9600 (출하값)","en":"9600 (default)"},{"value":4,"ko":"19200","en":"19200"},{"value":5,"ko":"38400","en":"38400"},{"value":6,"ko":"57600","en":"57600"},{"value":7,"ko":"115200","en":"115200"}],"ref":"p.85 Modbus Serial Communication Setup"},{"table":"holding-registers","address":1485,"manualAddress":"1486","type":"u16","name":{"ko":"RS-485 패리티","en":"RS-485 parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수 (출하값)","en":"Even (default)"}],"ref":"p.85 Modbus Serial Communication Setup"},{"table":"holding-registers","address":1486,"manualAddress":"1487","type":"u16","name":{"ko":"RS-485 정지 비트","en":"RS-485 stop bits"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트 (출하값)","en":"1 stop bit (default)"},{"value":1,"ko":"2비트","en":"2 stop bits"}],"ref":"p.85 Modbus Serial Communication Setup"},{"table":"holding-registers","address":11000,"manualAddress":"11001","type":"u16","name":{"ko":"집계 구간 선택","en":"Aggregation selection"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0.5초 데이터","en":"0.5 s data"},{"value":1,"ko":"1초 (출하값)","en":"1 s (default)"},{"value":2,"ko":"5초","en":"5 s"},{"value":3,"ko":"1분","en":"1 min"},{"value":4,"ko":"5분","en":"5 min"},{"value":5,"ko":"1시간","en":"1 h"},{"value":6,"ko":"6시간","en":"6 h"}],"description":{"ko":"11-15·200-202 등 다른 값도 있음 (p.105)","en":"Other values (11-15, 200-202) exist (p.105)"},"ref":"p.105 Measurement Map Summary"},{"table":"holding-registers","address":11043,"manualAddress":"11044","type":"u16","name":{"ko":"계측 데이터 접근(fetch)","en":"Measurement access (fetch)"},"access":"r","fc":[3],"description":{"ko":"읽으면 선택한 버퍼의 데이터가 11045-32300 으로 옮겨지고 그 버퍼 번호를 돌려준다. FFFFh = 버퍼 번호가 유효하지 않음","en":"Reading fetches the selected buffer into 11045-32300 and returns its index; FFFFh = invalid buffer index"},"ref":"p.105 Measurement Map Summary"},{"table":"holding-registers","address":11044,"manualAddress":"11045","type":"u16","name":{"ko":"2300 전압 데이터 유효성","en":"2300 voltage data validity"},"access":"r","fc":[3],"values":[{"value":0,"ko":"가져오지 못함","en":"Not fetched"},{"value":1,"ko":"정상","en":"Fetched"}],"ref":"p.106"},{"table":"holding-registers","address":11045,"manualAddress":"11046","type":"u16","name":{"ko":"모듈 ID 0 데이터 유효성","en":"Module ID 0 data validity"},"access":"r","fc":[3],"values":[{"value":0,"ko":"삼상 모듈 정상","en":"3-phase module OK"},{"value":1,"ko":"단상 모듈 정상","en":"1-phase module OK"},{"value":65535,"ko":"가져오지 못했거나 모듈 없음","en":"Not fetched or no module"}],"description":{"ko":"다른 모듈 종류 값(3, 7, 2001 등)은 p.106","en":"Other module type codes (3, 7, 2001…) on p.106"},"ref":"p.106"},{"table":"holding-registers","address":11100,"manualAddress":"11101","type":"f32","order":"ABCD","name":{"ko":"A상 상전압","en":"Voltage Van"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11102,"manualAddress":"11103","type":"f32","order":"ABCD","name":{"ko":"B상 상전압","en":"Voltage Vbn"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11104,"manualAddress":"11105","type":"f32","order":"ABCD","name":{"ko":"C상 상전압","en":"Voltage Vcn"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11106,"manualAddress":"11107","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average L-N voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11108,"manualAddress":"11109","type":"f32","order":"ABCD","name":{"ko":"AB 선간전압","en":"Voltage Vab"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11110,"manualAddress":"11111","type":"f32","order":"ABCD","name":{"ko":"BC 선간전압","en":"Voltage Vbc"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11112,"manualAddress":"11113","type":"f32","order":"ABCD","name":{"ko":"CA 선간전압","en":"Voltage Vca"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11114,"manualAddress":"11115","type":"f32","order":"ABCD","name":{"ko":"평균 선간전압","en":"Average L-L voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11150,"manualAddress":"11151","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11152,"manualAddress":"11153","type":"f32","order":"ABCD","name":{"ko":"2300 후면 온도","en":"2300 rear temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.108-109 Measurement Data for Accura 2300[S]"},{"table":"holding-registers","address":11200,"manualAddress":"11201","type":"f32","order":"ABCD","name":{"ko":"모듈0 A상 전류","en":"Module 0 current Ia"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 0"},{"table":"holding-registers","address":11202,"manualAddress":"11203","type":"f32","order":"ABCD","name":{"ko":"모듈0 B상 전류","en":"Module 0 current Ib"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 2"},{"table":"holding-registers","address":11204,"manualAddress":"11205","type":"f32","order":"ABCD","name":{"ko":"모듈0 C상 전류","en":"Module 0 current Ic"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 4"},{"table":"holding-registers","address":11206,"manualAddress":"11207","type":"f32","order":"ABCD","name":{"ko":"모듈0 평균 전류","en":"Module 0 current Iavg"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 6"},{"table":"holding-registers","address":11260,"manualAddress":"11261","type":"f32","order":"ABCD","name":{"ko":"모듈0 A상 유효전력","en":"Module 0 active power Pa"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 60"},{"table":"holding-registers","address":11262,"manualAddress":"11263","type":"f32","order":"ABCD","name":{"ko":"모듈0 B상 유효전력","en":"Module 0 active power Pb"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 62"},{"table":"holding-registers","address":11264,"manualAddress":"11265","type":"f32","order":"ABCD","name":{"ko":"모듈0 C상 유효전력","en":"Module 0 active power Pc"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 64"},{"table":"holding-registers","address":11266,"manualAddress":"11267","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 유효전력","en":"Module 0 total active power"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 66"},{"table":"holding-registers","address":11274,"manualAddress":"11275","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 무효전력","en":"Module 0 total reactive power"},"unit":"kVAR","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 74"},{"table":"holding-registers","address":11282,"manualAddress":"11283","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 피상전력","en":"Module 0 total apparent power"},"unit":"kVA","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 82"},{"table":"holding-registers","address":11286,"manualAddress":"11287","type":"s32","order":"ABCD","name":{"ko":"모듈0 수전 유효전력량","en":"Module 0 received kWh"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 86"},{"table":"holding-registers","address":11288,"manualAddress":"11289","type":"s32","order":"ABCD","name":{"ko":"모듈0 송전 유효전력량","en":"Module 0 delivered kWh"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 88"},{"table":"holding-registers","address":11294,"manualAddress":"11295","type":"s32","order":"ABCD","name":{"ko":"모듈0 양의 무효전력량","en":"Module 0 received kVARh"},"unit":"kVARh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 94"},{"table":"holding-registers","address":11296,"manualAddress":"11297","type":"s32","order":"ABCD","name":{"ko":"모듈0 음의 무효전력량","en":"Module 0 delivered kVARh"},"unit":"kVARh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 96"},{"table":"holding-registers","address":11302,"manualAddress":"11303","type":"s32","order":"ABCD","name":{"ko":"모듈0 피상전력량","en":"Module 0 kVAh"},"unit":"kVAh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 102"},{"table":"holding-registers","address":11310,"manualAddress":"11311","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 유효전력 디맨드","en":"Module 0 total demand kW"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 110"},{"table":"holding-registers","address":11324,"manualAddress":"11325","type":"f32","order":"ABCD","name":{"ko":"모듈0 A상 역률","en":"Module 0 PF A"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 124"},{"table":"holding-registers","address":11326,"manualAddress":"11327","type":"f32","order":"ABCD","name":{"ko":"모듈0 B상 역률","en":"Module 0 PF B"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 126"},{"table":"holding-registers","address":11328,"manualAddress":"11329","type":"f32","order":"ABCD","name":{"ko":"모듈0 C상 역률","en":"Module 0 PF C"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 128"},{"table":"holding-registers","address":11330,"manualAddress":"11331","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 역률","en":"Module 0 total PF"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (Accura 2350-3P, 3P 결선 모드). ID n 은 주소에 150×n 을 더한다","en":"Module ID 0 (Accura 2350-3P, 3P wiring mode). For ID n add 150×n"},"ref":"p.110-112 Detailed Data for Accura 2350-3P (3P Mode), ID 0 = 11201 + offset offset 130"}],"notes":[{"ko":"계측 레지스터(11045-32300)는 PR 속성 — 접속마다 따로 있는 공간이라 11044 를 읽어 데이터를 가져온 뒤 읽어야 값이 채워진다 (p.32, p.105).","en":"Measurement registers (11045-32300) are private-read: per-connection space, filled only after reading 11044 (p.32, p.105)."},{"ko":"2350 모듈 데이터는 ID 0 이 11201 에서 시작하고 모듈마다 150 칸 (p.110). 여기 적은 모듈 레지스터는 2350-3P 를 3P(또는 1P2F) 결선으로 쓸 때의 표 — 다른 결선·모듈 종류는 표가 다르다.","en":"2350 module data starts at 11201 for ID 0, 150 registers per module (p.110). Module registers here follow the 2350-3P table for 3P (or 1P2F) wiring; other wiring/module types use different tables."},{"ko":"값은 실제 단위 Float32(V·A·kW…), 전력량은 Int32 kWh 등 — PT/CT 배율을 따로 곱하지 않는다.","en":"Values are Float32 in engineering units; energies Int32 kWh etc. No separate PT/CT scaling."},{"ko":"원격 설정은 기본 잠금 — 쓰기 전에 700 에 2300→0→700→1 을 써서 해제 (p.38). 직렬 설정은 1483 접근 레지스터로 가져오기/적용 (p.85).","en":"Remote setup is locked by default; unlock by writing 2300→0→700→1 to 700 before writes (p.38). Serial settings are fetched/applied via access register 1483 (p.85)."},{"ko":"역률 유효성(오프셋 132-135)과 진상·지상(136-139)은 별도 레지스터 (p.112).","en":"PF validity (offset 132-135) and lead/lag (136-139) are separate registers (p.112)."}],"sources":[{"title":"Accura 2300[S]/2350 Communication Guide","publisher":"Rootech Inc.","edition":{"ko":"Rev 2.50, 2026-06-23 (파일명 Accura_2300[S]_2350_Communication_Guide_Rev2_50_Korean_260623.pdf)","en":"Rev 2.50, 2026-06-23 (file name Accura_2300[S]_2350_Communication_Guide_Rev2_50_Korean_260623.pdf)"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1474&no=0","pages":{"ko":"p.14-19 프로토콜·함수 코드, p.28-30 맵 요약·형식, p.34, p.38, p.85, p.105-112 계측","en":"pp.14-19 protocol and function codes, pp.28-30 map summary and formats, p.34, p.38, p.85, pp.105-112 measurements"},"checked":"2026-10-19"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"rootech/accura-2500","manufacturer":{"ko":"루텍","en":"Rootech"},"model":"Accura 2500","models":["Accura 2500M","Accura 2500D","Accura 2550"],"kind":"power-meter","title":{"ko":"루텍 Accura 2500M 분전반 통합 모듈 + Accura 2550 계측 모듈 (AC)","en":"Rootech Accura 2500M panel integration module with Accura 2550 measurement modules (AC)"},"summary":{"ko":"2500M 이 분전반 인입 전압을 재고 내부 통신으로 붙은 Accura 2550 모듈(ID 0-39)의 전류·전력·전력량을 모아 Modbus RTU/TCP 로 내준다. 계측값은 9911 을 읽어 가져온(fetch) 뒤 읽는다.","en":"The 2500M measures panel voltage and collects current/power/energy from up to 40 Accura 2550 modules (ID 0-39), served over Modbus RTU/TCP. Read 9911 to fetch before reading measurements."},"protocols":["rtu","tcp"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,115200],"parity":"even","stopBits":1,"tcpPort":502,"order":"ABCD","maxRegisters":125,"addressing":"one","notes":[{"ko":"매뉴얼은 레지스터 번호(1 기준) — 통신 주소 = 번호 − 1. 예: 10001 은 2710h 로 보낸다 (p.16, p.234, p.243).","en":"Manual uses 1-based register numbers; wire address = number − 1, e.g. 10001 is sent as 2710h (p.16, p.234, p.243)."},{"ko":"32비트는 상위 워드가 낮은 주소(Big-endian) (p.18, p.244).","en":"32-bit values: high word at lower address (big-endian) (p.18, p.244)."},{"ko":"RS-485 출하값 9600 bps·짝수 패리티·정지 1비트, 국번 범위 0-247 에 Default 0 으로 적혀 있어 출하 국번은 비워 둠 (p.40). 패리티 코드는 0 None·1 Odd·2 Even.","en":"RS-485 defaults 9600 bps, even parity, 1 stop bit; address range 0-247 with default 0, so factory unit ID is left out (p.40). Parity codes: 0 none, 1 odd, 2 even."},{"ko":"함수 코드 03·06·16, 사용자 정의 101(65h, TCP 전용). 읽기 수량 표준 1-125(장치는 250 까지 허용하나 128 이상은 byte count 넘침). Modbus TCP 포트 502, Unit ID 1 고정, 동시 접속 20(TCP 19, RTU 1) (p.230-234).","en":"FC 03, 06, 16 plus user-defined 101 (65h, TCP only). Read quantity 1-125 (device allows 250, byte count overflows from 128). Modbus TCP port 502, unit ID fixed at 1, 20 connections (19 TCP, 1 RTU) (p.230-234)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"1","type":"u16","name":{"ko":"제품 ID","en":"Product ID"},"access":"r","fc":[3],"description":{"ko":"Accura 2500M = 2500","en":"Accura 2500M = 2500"},"ref":"p.19 Main System Information"},{"table":"holding-registers","address":2,"manualAddress":"3","type":"u32","order":"ABCD","name":{"ko":"일련번호","en":"Serial number"},"access":"r","fc":[3],"ref":"p.19 Main System Information"},{"table":"holding-registers","address":7,"manualAddress":"8","type":"u16","name":{"ko":"소프트웨어 주 버전","en":"Major application version"},"access":"r","fc":[3],"ref":"p.19 Main System Information"},{"table":"holding-registers","address":8,"manualAddress":"9","type":"u16","name":{"ko":"소프트웨어 부 버전","en":"Minor application version"},"access":"r","fc":[3],"ref":"p.19 Main System Information"},{"table":"holding-registers","address":9,"manualAddress":"10","type":"u16","name":{"ko":"소프트웨어 개정 버전","en":"Application revised version"},"access":"r","fc":[3],"ref":"p.19 Main System Information"},{"table":"holding-registers","address":2900,"manualAddress":"2901","type":"u16","name":{"ko":"원격 설정 잠금","en":"Remote setup lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제","en":"Unlocked"},{"value":1,"ko":"잠금","en":"Locked"}],"description":{"ko":"2300 → 0 → 700 → 1 을 차례로 쓰면 해제, 아무 값이나 쓰면 잠금. 접속마다 따로, 전원을 끄면 다시 잠김.","en":"Write 2300 → 0 → 700 → 1 to unlock; any other write locks. Per connection; relocks at power-off."},"ref":"p.30 Remote Setup Unlock"},{"table":"holding-registers","address":3700,"manualAddress":"3701","type":"u16","name":{"ko":"RS-485 설정 접근","en":"Access for RS-485 setup"},"access":"rw","fc":[3,6,16],"description":{"ko":"읽으면 장치 설정을 3702~3705 로 가져온다(성공 시 Bit 15 = 1). 1 을 쓰면 3702~3705 값을 장치에 적용.","en":"Read fetches device settings into 3702-3705 (bit 15 = 1 on success); write 1 to apply 3702-3705."},"ref":"p.40 RS-485 Setup"},{"table":"holding-registers","address":3701,"manualAddress":"3702","type":"u16","name":{"ko":"RS-485 국번","en":"RS-485 device address"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":247},"ref":"p.40 RS-485 Setup"},{"table":"holding-registers","address":3702,"manualAddress":"3703","type":"u16","name":{"ko":"RS-485 통신 속도","en":"RS-485 bit rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200 bps","en":"1200 bps"},{"value":1,"ko":"2400 bps","en":"2400 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"9600 bps","en":"9600 bps"},{"value":4,"ko":"19200 bps","en":"19200 bps"},{"value":5,"ko":"38400 bps","en":"38400 bps"},{"value":6,"ko":"57600 bps","en":"57600 bps"},{"value":7,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.40 RS-485 Setup"},{"table":"holding-registers","address":3703,"manualAddress":"3704","type":"u16","name":{"ko":"RS-485 패리티","en":"RS-485 parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수","en":"Even"}],"ref":"p.40 RS-485 Setup"},{"table":"holding-registers","address":3704,"manualAddress":"3705","type":"u16","name":{"ko":"RS-485 정지 비트","en":"RS-485 stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 stop bit"},{"value":1,"ko":"2비트","en":"2 stop bits"}],"ref":"p.40 RS-485 Setup"},{"table":"holding-registers","address":9900,"manualAddress":"9901","type":"u16","name":{"ko":"Aggregation 선택","en":"Aggregation selection"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0.2초","en":"0.2 s"},{"value":1,"ko":"고정 1 (1초)","en":"Fixed 1 (1 s)"},{"value":2,"ko":"고정 2 (5초)","en":"Fixed 2 (5 s)"},{"value":3,"ko":"고정 3 (1분)","en":"Fixed 3 (1 min)"},{"value":4,"ko":"고정 4 (5분)","en":"Fixed 4 (5 min)"},{"value":5,"ko":"고정 5 (1시간)","en":"Fixed 5 (1 h)"},{"value":6,"ko":"고정 6 (6시간)","en":"Fixed 6 (6 h)"},{"value":11,"ko":"사용자 11","en":"User-defined 11"},{"value":12,"ko":"사용자 12","en":"User-defined 12"},{"value":13,"ko":"사용자 13","en":"User-defined 13"},{"value":14,"ko":"사용자 14","en":"User-defined 14"},{"value":15,"ko":"사용자 15","en":"User-defined 15"},{"value":255,"ko":"Max/Min (리셋 이후)","en":"Max/Min since reset"}],"ref":"p.98 Aggregation Selection & Data Fetch"},{"table":"holding-registers","address":9903,"manualAddress":"9904","type":"u16","name":{"ko":"Index 선택","en":"Index selection"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.98 Aggregation Selection & Data Fetch"},{"table":"holding-registers","address":9905,"manualAddress":"9906","type":"u16","name":{"ko":"최신 index","en":"Newest index"},"access":"r","fc":[3],"ref":"p.98 Aggregation Selection & Data Fetch"},{"table":"holding-registers","address":9910,"manualAddress":"9911","type":"u16","name":{"ko":"데이터 가져오기(fetch)","en":"Data fetch"},"access":"r","fc":[3],"values":[{"value":0,"ko":"실패","en":"Fetch failed"},{"value":1,"ko":"성공","en":"Fetch succeeded"}],"description":{"ko":"읽으면 선택한 index 의 aggregation 데이터를 가져와 계측 영역(9914~)에 채운다. 9902 기본 모드(1)는 최신 index 로 바꾼 뒤 가져온다.","en":"Reading fetches the selected index into the measurement area (9914-). Default index update mode 9902 = 1 switches to the newest index first."},"ref":"p.98 Aggregation Selection & Data Fetch"},{"table":"holding-registers","address":9929,"manualAddress":"9930","type":"u16","name":{"ko":"2500M 전압 데이터 유효성","en":"Validity of 2500M voltage data"},"access":"r","fc":[3],"values":[{"value":0,"ko":"유효하지 않음","en":"Invalid"},{"value":1,"ko":"2500M (AC 모드)","en":"2500M (AC mode)"}],"ref":"p.99 Measurement Header"},{"table":"holding-registers","address":9930,"manualAddress":"9931","type":"u16","name":{"ko":"모듈 ID 0 데이터 형식·유효성","en":"Module ID 0 data type & validity"},"access":"r","fc":[3],"description":{"ko":"Bit 15-8 모듈 형식(0 무효, 3 CM[Z]-1P, 4 CM[Z]-3P·CMM[Z]-3P·CMZ-3P4W, 5 CMS-1P3F, 6 CMS-1P2F, 7 CMS-3P4W, 8 CMS-2P, 10 IO, 11 TEMP, 12 GW, 13 DCM, 14 SAL, 16 VOL, 17 GWM, 19 VOC), Bit 7-4 세부 속성, Bit 3-0 동작 모드. ID 1~39 는 9932~9970.","en":"Bits 15-8 module type (0 invalid, 3 CM[Z]-1P, 4 CM[Z]-3P/CMM[Z]-3P/CMZ-3P4W, 5 CMS-1P3F, 6 CMS-1P2F, 7 CMS-3P4W, 8 CMS-2P, 10 IO, 11 TEMP, 12 GW, 13 DCM, 14 SAL, 16 VOL, 17 GWM, 19 VOC), bits 7-4 sub-type, bits 3-0 mode. IDs 1-39 at 9932-9970."},"ref":"p.99-100 Measurement Header"},{"table":"holding-registers","address":10000,"manualAddress":"10001","type":"f32","order":"ABCD","name":{"ko":"A상 상전압","en":"Voltage Van"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10002,"manualAddress":"10003","type":"f32","order":"ABCD","name":{"ko":"B상 상전압","en":"Voltage Vbn"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10004,"manualAddress":"10005","type":"f32","order":"ABCD","name":{"ko":"C상 상전압","en":"Voltage Vcn"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10006,"manualAddress":"10007","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average L-N voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10010,"manualAddress":"10011","type":"f32","order":"ABCD","name":{"ko":"AB 선간전압","en":"Voltage Vab"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10012,"manualAddress":"10013","type":"f32","order":"ABCD","name":{"ko":"BC 선간전압","en":"Voltage Vbc"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10014,"manualAddress":"10015","type":"f32","order":"ABCD","name":{"ko":"CA 선간전압","en":"Voltage Vca"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10016,"manualAddress":"10017","type":"f32","order":"ABCD","name":{"ko":"평균 선간전압","en":"Average L-L voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10036,"manualAddress":"10037","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10038,"manualAddress":"10039","type":"f32","order":"ABCD","name":{"ko":"A상 전압 THD","en":"Voltage THD A"},"unit":"%","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10040,"manualAddress":"10041","type":"f32","order":"ABCD","name":{"ko":"B상 전압 THD","en":"Voltage THD B"},"unit":"%","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10042,"manualAddress":"10043","type":"f32","order":"ABCD","name":{"ko":"C상 전압 THD","en":"Voltage THD C"},"unit":"%","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10050,"manualAddress":"10051","type":"f32","order":"ABCD","name":{"ko":"상전압 불평형률","en":"Voltage unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.101 Main Measurement Data"},{"table":"holding-registers","address":10500,"manualAddress":"10501","type":"f32","order":"ABCD","name":{"ko":"모듈0 A상 전류","en":"Module 0 current Ia"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 0"},{"table":"holding-registers","address":10502,"manualAddress":"10503","type":"f32","order":"ABCD","name":{"ko":"모듈0 B상 전류","en":"Module 0 current Ib"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 2"},{"table":"holding-registers","address":10504,"manualAddress":"10505","type":"f32","order":"ABCD","name":{"ko":"모듈0 C상 전류","en":"Module 0 current Ic"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 4"},{"table":"holding-registers","address":10506,"manualAddress":"10507","type":"f32","order":"ABCD","name":{"ko":"모듈0 평균 전류","en":"Module 0 average current"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 6"},{"table":"holding-registers","address":10520,"manualAddress":"10521","type":"f32","order":"ABCD","name":{"ko":"모듈0 A상 유효전력","en":"Module 0 active power Pa"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 20"},{"table":"holding-registers","address":10522,"manualAddress":"10523","type":"f32","order":"ABCD","name":{"ko":"모듈0 B상 유효전력","en":"Module 0 active power Pb"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 22"},{"table":"holding-registers","address":10524,"manualAddress":"10525","type":"f32","order":"ABCD","name":{"ko":"모듈0 C상 유효전력","en":"Module 0 active power Pc"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 24"},{"table":"holding-registers","address":10526,"manualAddress":"10527","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 유효전력","en":"Module 0 total active power"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 26"},{"table":"holding-registers","address":10534,"manualAddress":"10535","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 무효전력","en":"Module 0 total reactive power"},"unit":"kVAR","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 34"},{"table":"holding-registers","address":10542,"manualAddress":"10543","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 피상전력","en":"Module 0 total apparent power"},"unit":"kVA","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 42"},{"table":"holding-registers","address":10544,"manualAddress":"10545","type":"f32","order":"ABCD","name":{"ko":"모듈0 A상 역률","en":"Module 0 PF A"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 44"},{"table":"holding-registers","address":10546,"manualAddress":"10547","type":"f32","order":"ABCD","name":{"ko":"모듈0 B상 역률","en":"Module 0 PF B"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 46"},{"table":"holding-registers","address":10548,"manualAddress":"10549","type":"f32","order":"ABCD","name":{"ko":"모듈0 C상 역률","en":"Module 0 PF C"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 48"},{"table":"holding-registers","address":10550,"manualAddress":"10551","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 역률","en":"Module 0 total PF"},"access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 50"},{"table":"holding-registers","address":10600,"manualAddress":"10601","type":"f32","order":"ABCD","name":{"ko":"모듈0 누설전류","en":"Module 0 leakage current"},"unit":"A","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 100"},{"table":"holding-registers","address":10768,"manualAddress":"10769","type":"f32","order":"ABCD","name":{"ko":"모듈0 총 전력 디맨드","en":"Module 0 total demand power"},"unit":"kW","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 268"},{"table":"holding-registers","address":10599,"manualAddress":"10600","type":"u16","name":{"ko":"모듈0 총 역률 위상각 상태","en":"Module 0 total PF angle status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"진상","en":"Lead PF"},{"value":2,"ko":"지상","en":"Lag PF"},{"value":3,"ko":"무효(피상전력 0)","en":"Invalid (apparent power 0)"}],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 99"},{"table":"holding-registers","address":10774,"manualAddress":"10775","type":"s32","order":"ABCD","name":{"ko":"모듈0 수전 유효전력량","en":"Module 0 received active energy"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 274"},{"table":"holding-registers","address":10776,"manualAddress":"10777","type":"s32","order":"ABCD","name":{"ko":"모듈0 송전 유효전력량","en":"Module 0 delivered active energy"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 276"},{"table":"holding-registers","address":10790,"manualAddress":"10791","type":"s32","order":"ABCD","name":{"ko":"모듈0 양의 무효전력량","en":"Module 0 positive reactive energy"},"unit":"kVARh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 290"},{"table":"holding-registers","address":10792,"manualAddress":"10793","type":"s32","order":"ABCD","name":{"ko":"모듈0 음의 무효전력량","en":"Module 0 negative reactive energy"},"unit":"kVARh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 292"},{"table":"holding-registers","address":10798,"manualAddress":"10799","type":"s32","order":"ABCD","name":{"ko":"모듈0 피상전력량","en":"Module 0 apparent energy"},"unit":"kVAh","access":"r","fc":[3],"description":{"ko":"모듈 ID 0 (CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 표). ID N 은 주소에 500×N 을 더한다 (p.103).","en":"Module ID 0 (CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table). For ID N add 500×N (p.103)."},"ref":"p.103-106 3-Phase Measurement Data, ID 0 = 10501 + offset offset 298"},{"table":"holding-registers","address":65525,"manualAddress":"65526","type":"u16","name":{"ko":"주소 시험값 (4142h)","en":"Modbus test address (4142h)"},"access":"r","fc":[3],"description":{"ko":"주소·엔디언 점검용 상수. 65527 부터 2워드를 읽어 43 44 45 46h 가 오면 주소가 맞다.","en":"Constant for address/endian checks: reading 2 words from 65527 should return 43 44 45 46h."},"ref":"p.244 Modbus Test Address"},{"table":"holding-registers","address":65526,"manualAddress":"65527","type":"u16","name":{"ko":"주소 시험값 (4344h)","en":"Modbus test address (4344h)"},"access":"r","fc":[3],"description":{"ko":"주소·엔디언 점검용 상수. 65527 부터 2워드를 읽어 43 44 45 46h 가 오면 주소가 맞다.","en":"Constant for address/endian checks: reading 2 words from 65527 should return 43 44 45 46h."},"ref":"p.244 Modbus Test Address"},{"table":"holding-registers","address":65527,"manualAddress":"65528","type":"u16","name":{"ko":"주소 시험값 (4546h)","en":"Modbus test address (4546h)"},"access":"r","fc":[3],"description":{"ko":"주소·엔디언 점검용 상수. 65527 부터 2워드를 읽어 43 44 45 46h 가 오면 주소가 맞다.","en":"Constant for address/endian checks: reading 2 words from 65527 should return 43 44 45 46h."},"ref":"p.244 Modbus Test Address"},{"table":"holding-registers","address":65528,"manualAddress":"65529","type":"u16","name":{"ko":"주소 시험값 (4748h)","en":"Modbus test address (4748h)"},"access":"r","fc":[3],"description":{"ko":"주소·엔디언 점검용 상수. 65527 부터 2워드를 읽어 43 44 45 46h 가 오면 주소가 맞다.","en":"Constant for address/endian checks: reading 2 words from 65527 should return 43 44 45 46h."},"ref":"p.244 Modbus Test Address"}],"notes":[{"ko":"계측값은 aggregation 버퍼에 있다 — 9901 로 구간(기본 1초)을 고르고 9911 을 읽어 가져온 뒤 10001~ 을 읽는다. 선택·index 는 접속마다 따로 (p.95-98, p.233).","en":"Measurements live in aggregation buffers: select the interval with 9901 (default 1 s), read 9911 to fetch, then read 10001-. Selection/index are per connection (p.95-98, p.233)."},{"ko":"2550 모듈 데이터는 ID 0 이 10501 에서 시작하고 모듈마다 500 칸 (p.103). 여기 적은 모듈 레지스터는 CM[Z]-3P·CMS-3P4W·CMM[Z]-3P 3상 표 — 1P·1P3F·2P·DCM 등 다른 모듈은 표가 다르다. 9931 로 모듈 형식을 먼저 확인.","en":"2550 module data starts at 10501 for ID 0, 500 registers per module (p.103). Module registers here follow the 3-phase CM[Z]-3P / CMS-3P4W / CMM[Z]-3P table; other module types use different tables. Check the type in 9931 first."},{"ko":"값은 실제 단위 Float32(V·A·kW…), 전력량은 Int32 kWh 등. 전력량 단위는 Locale > Energy Unit 설정으로 바뀔 수 있다 (p.103).","en":"Values are Float32 in engineering units; energies Int32 kWh etc. The energy unit can change with the Locale > Energy Unit setting (p.103)."},{"ko":"원격 설정은 기본 잠금 — 쓰기 전에 2901 에 2300→0→700→1 을 써서 해제 (p.30, p.246). 직렬 설정은 3701 접근 레지스터로 가져오기/적용 (p.40).","en":"Remote setup is locked by default; unlock by writing 2300→0→700→1 to 2901 (p.30, p.246). Serial settings are fetched/applied via access register 3701 (p.40)."}],"sources":[{"title":"Accura 2500/2550 Communication Guide [AC]","publisher":"Rootech Inc.","edition":{"ko":"Rev 2.00, 2026-08-14 (파일명 Accura_2500_2550_AC_Communication Guide_Rev2_00_Korean_260814.pdf)","en":"Rev 2.00, 2026-08-14 (file name Accura_2500_2550_AC_Communication Guide_Rev2_00_Korean_260814.pdf)"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1480&no=0","pages":{"ko":"p.16-19 맵 요약·형식·시스템 정보, p.30, p.40, p.95-106 계측, p.230-235 프로토콜, p.243-246 주소·엔디언","en":"pp.16-19 map summary, formats, system info, p.30, p.40, pp.95-106 measurements, pp.230-235 protocol, pp.243-246 addressing and endian"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"rootech/accura-2700","manufacturer":{"ko":"루텍","en":"Rootech"},"model":"Accura 2700M","models":["Accura 2700M","Accura 2700D"],"kind":"power-meter","title":{"ko":"루텍 Accura 2700M MCC 인입유닛 통합모듈 (전력 계측)","en":"Rootech Accura 2700M MCC incoming-unit integration module (power metering)"},"summary":{"ko":"스마트 모터 관리 시스템(MCC) Accura 2700/2750 의 인입유닛 통합모듈. 인입단 전압·전류·전력·전력량을 Modbus RTU/TCP 로 내준다. 4001 을 읽어 가져온(fetch) 뒤 4002~4206 을 읽는다. 2750 모터 모듈 데이터는 담지 않았다.","en":"Incoming-unit integration module of the Accura 2700/2750 smart motor management (MCC) system. Serves incomer voltage/current/power/energy over Modbus RTU/TCP; read 4001 to fetch, then 4002-4206. Accura 2750 motor-module data is not included."},"protocols":["rtu","tcp"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,115200],"parity":"even","stopBits":1,"tcpPort":502,"order":"ABCD","maxRegisters":125,"addressing":"one","notes":[{"ko":"매뉴얼은 레지스터 번호(1 기준) — 통신 주소 = 번호 − 1 (p.18, p.189, p.191).","en":"Manual uses 1-based register numbers; wire address = number − 1 (p.18, p.189, p.191)."},{"ko":"32비트는 상위 워드가 낮은 주소(Big-endian) (p.20).","en":"32-bit values: high word at lower address (big-endian) (p.20)."},{"ko":"RS-485 출하값 9600 bps·짝수 패리티·정지 1비트. 국번 범위 0-247 에 Default 0 으로 적혀 있어 출하 국번은 비워 둠 (p.42).","en":"RS-485 defaults 9600 bps, even parity, 1 stop bit; address range 0-247 with default 0, so factory unit ID is left out (p.42)."},{"ko":"함수 코드 03·06·16, 사용자 정의 101(65h, TCP 전용). 읽기 수량 표준 1-125(장치는 250 까지). Modbus TCP 포트 502, Unit ID 1 고정, 동시 접속 20(TCP 19, RTU 1) (p.186-191).","en":"FC 03, 06, 16 plus user-defined 101 (65h, TCP only). Read quantity 1-125 (device allows 250). Modbus TCP port 502, unit ID fixed at 1, 20 connections (19 TCP, 1 RTU) (p.186-191)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"1","type":"u16","name":{"ko":"제품 ID","en":"Product ID"},"access":"r","fc":[3],"description":{"ko":"Accura 2700M = 2700","en":"Accura 2700M = 2700"},"ref":"p.21 System Information for Accura 2700M"},{"table":"holding-registers","address":2,"manualAddress":"3","type":"u32","order":"ABCD","name":{"ko":"일련번호","en":"Serial number"},"access":"r","fc":[3],"ref":"p.21 System Information for Accura 2700M"},{"table":"holding-registers","address":7,"manualAddress":"8","type":"u16","name":{"ko":"소프트웨어 버전","en":"Application version"},"access":"r","fc":[3],"ref":"p.21 System Information for Accura 2700M"},{"table":"holding-registers","address":22,"manualAddress":"23","type":"u16","name":{"ko":"2700M 모델 형식","en":"2700M model type"},"access":"r","fc":[3],"values":[{"value":0,"ko":"CT 5A 모델","en":"CT5A model"},{"value":1,"ko":"CT 1A 모델","en":"CT1A model"}],"ref":"p.22 System Information for Accura 2700M"},{"table":"holding-registers","address":24,"manualAddress":"25","type":"u16","name":{"ko":"맵 버전","en":"Map version"},"access":"r","fc":[3],"description":{"ko":"10진 [d1][d2][d3][d4][d5]: d1 주 버전, d2 부 버전, d3~d5 패치","en":"Decimal [d1][d2][d3][d4][d5]: d1 major, d2 minor, d3-d5 patch"},"ref":"p.22 System Information for Accura 2700M"},{"table":"holding-registers","address":4000,"manualAddress":"4001","type":"u16","name":{"ko":"2700M 계측 데이터 가져오기","en":"Access to 2700M measurement data"},"access":"r","fc":[3],"description":{"ko":"읽으면 4002~4206 에 계측 데이터를 가져온다(fetch). 성공 시 1.","en":"Reading fetches measurement data into 4002-4206; 1 on success."},"ref":"p.96 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4001,"manualAddress":"4002","type":"u16","name":{"ko":"하트비트","en":"Heartbeat"},"access":"r","fc":[3],"description":{"ko":"계측 데이터가 갱신될 때마다 증가","en":"Increments on each measurement update"},"ref":"p.96 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4002,"manualAddress":"4003","type":"f32","order":"ABCD","name":{"ko":"A상 상전압","en":"Voltage Van"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4004,"manualAddress":"4005","type":"f32","order":"ABCD","name":{"ko":"B상 상전압","en":"Voltage Vbn"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4006,"manualAddress":"4007","type":"f32","order":"ABCD","name":{"ko":"C상 상전압","en":"Voltage Vcn"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4008,"manualAddress":"4009","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average L-N voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4010,"manualAddress":"4011","type":"f32","order":"ABCD","name":{"ko":"AB 선간전압","en":"Voltage Vab"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4012,"manualAddress":"4013","type":"f32","order":"ABCD","name":{"ko":"BC 선간전압","en":"Voltage Vbc"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4014,"manualAddress":"4015","type":"f32","order":"ABCD","name":{"ko":"CA 선간전압","en":"Voltage Vca"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4016,"manualAddress":"4017","type":"f32","order":"ABCD","name":{"ko":"평균 선간전압","en":"Average L-L voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4056,"manualAddress":"4057","type":"f32","order":"ABCD","name":{"ko":"상전압 불평형률","en":"L-N voltage unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4070,"manualAddress":"4071","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4072,"manualAddress":"4073","type":"f32","order":"ABCD","name":{"ko":"A상 전류","en":"Current Ia"},"unit":"A","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4074,"manualAddress":"4075","type":"f32","order":"ABCD","name":{"ko":"B상 전류","en":"Current Ib"},"unit":"A","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4076,"manualAddress":"4077","type":"f32","order":"ABCD","name":{"ko":"C상 전류","en":"Current Ic"},"unit":"A","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4078,"manualAddress":"4079","type":"f32","order":"ABCD","name":{"ko":"평균 전류","en":"Average current"},"unit":"A","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4106,"manualAddress":"4107","type":"f32","order":"ABCD","name":{"ko":"전류 불평형률","en":"Current unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4112,"manualAddress":"4113","type":"f32","order":"ABCD","name":{"ko":"A상 전류 THD","en":"Current THD A"},"unit":"%","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4114,"manualAddress":"4115","type":"f32","order":"ABCD","name":{"ko":"B상 전류 THD","en":"Current THD B"},"unit":"%","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4116,"manualAddress":"4117","type":"f32","order":"ABCD","name":{"ko":"C상 전류 THD","en":"Current THD C"},"unit":"%","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4136,"manualAddress":"4137","type":"f32","order":"ABCD","name":{"ko":"A상 유효전력","en":"Active power Pa"},"unit":"kW","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4138,"manualAddress":"4139","type":"f32","order":"ABCD","name":{"ko":"B상 유효전력","en":"Active power Pb"},"unit":"kW","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4140,"manualAddress":"4141","type":"f32","order":"ABCD","name":{"ko":"C상 유효전력","en":"Active power Pc"},"unit":"kW","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4142,"manualAddress":"4143","type":"f32","order":"ABCD","name":{"ko":"총 유효전력","en":"Total active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4150,"manualAddress":"4151","type":"f32","order":"ABCD","name":{"ko":"총 무효전력","en":"Total reactive power"},"unit":"kVAR","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4158,"manualAddress":"4159","type":"f32","order":"ABCD","name":{"ko":"총 피상전력","en":"Total apparent power"},"unit":"kVA","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4160,"manualAddress":"4161","type":"f32","order":"ABCD","name":{"ko":"A상 역률","en":"Power factor A"},"access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4162,"manualAddress":"4163","type":"f32","order":"ABCD","name":{"ko":"B상 역률","en":"Power factor B"},"access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4164,"manualAddress":"4165","type":"f32","order":"ABCD","name":{"ko":"C상 역률","en":"Power factor C"},"access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4166,"manualAddress":"4167","type":"f32","order":"ABCD","name":{"ko":"총 역률","en":"Total power factor"},"access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4171,"manualAddress":"4172","type":"u16","name":{"ko":"총 역률 위상각 상태","en":"Total power factor angle status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"진상","en":"Leading"},{"value":2,"ko":"지상","en":"Lagging"},{"value":3,"ko":"무효(피상전력 0)","en":"Invalid (apparent power 0)"}],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4178,"manualAddress":"4179","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total demand active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4186,"manualAddress":"4187","type":"f32","order":"ABCD","name":{"ko":"평균 전류 디맨드","en":"Average demand current"},"unit":"A","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4188,"manualAddress":"4189","type":"u32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Received active energy"},"unit":"kWh","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4190,"manualAddress":"4191","type":"u32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Delivered active energy"},"unit":"kWh","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4192,"manualAddress":"4193","type":"s32","order":"ABCD","name":{"ko":"유효전력량 차(수전-송전)","en":"Net active energy"},"unit":"kWh","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4196,"manualAddress":"4197","type":"u32","order":"ABCD","name":{"ko":"양의 무효전력량","en":"Positive reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4198,"manualAddress":"4199","type":"u32","order":"ABCD","name":{"ko":"음의 무효전력량","en":"Negative reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":4204,"manualAddress":"4205","type":"u32","order":"ABCD","name":{"ko":"피상전력량","en":"Apparent energy"},"unit":"kVAh","access":"r","fc":[3],"ref":"p.96-99 Measurement Data for Accura 2700M"},{"table":"holding-registers","address":50999,"manualAddress":"51000","type":"u16","name":{"ko":"원격 설정 잠금","en":"Remote setup unlock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제","en":"Unlocked"},{"value":1,"ko":"잠금","en":"Locked"}],"description":{"ko":"2300 → 0 → 700 → 1 을 차례로 쓰면 해제, 아무 값이나 쓰면 잠금. 접속마다 따로.","en":"Write 2300 → 0 → 700 → 1 to unlock; any other write locks. Per connection."},"ref":"p.36 Remote Setup Unlock"},{"table":"holding-registers","address":51170,"manualAddress":"51171","type":"u16","name":{"ko":"RS-485 설정 접근","en":"Access to RS-485 setup"},"access":"rw","fc":[3,6,16],"description":{"ko":"읽으면 장치 설정을 51172~51175 로 가져온다(성공 시 Bit 15 = 1). 1 을 쓰면 적용.","en":"Read fetches settings into 51172-51175 (bit 15 = 1 on success); write 1 to apply."},"ref":"p.42 RS-485 Setup"},{"table":"holding-registers","address":51171,"manualAddress":"51172","type":"u16","name":{"ko":"RS-485 국번","en":"RS-485 device address"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":247},"description":{"ko":"통신 가능한 ID 는 1~247","en":"Usable IDs 1-247"},"ref":"p.42 RS-485 Setup"},{"table":"holding-registers","address":51172,"manualAddress":"51173","type":"u16","name":{"ko":"RS-485 통신 속도","en":"RS-485 baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200 bps","en":"1200 bps"},{"value":1,"ko":"2400 bps","en":"2400 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"9600 bps","en":"9600 bps"},{"value":4,"ko":"19200 bps","en":"19200 bps"},{"value":5,"ko":"38400 bps","en":"38400 bps"},{"value":6,"ko":"57600 bps","en":"57600 bps"},{"value":7,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.42 RS-485 Setup"},{"table":"holding-registers","address":51173,"manualAddress":"51174","type":"u16","name":{"ko":"RS-485 패리티","en":"RS-485 parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수","en":"Even"}],"ref":"p.42 RS-485 Setup"},{"table":"holding-registers","address":51174,"manualAddress":"51175","type":"u16","name":{"ko":"RS-485 정지 비트","en":"RS-485 stop bits"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 stop bit"},{"value":1,"ko":"2비트","en":"2 stop bits"}],"ref":"p.42 RS-485 Setup"}],"notes":[{"ko":"계측값은 4001 을 읽어 가져온 뒤 읽는다 — 가져온 데이터는 접속마다 따로 (p.96, p.190).","en":"Read 4001 to fetch before reading measurements; fetched data is per connection (p.96, p.190)."},{"ko":"원격 설정은 기본 잠금 — 쓰기 전에 51000 에 2300→0→700→1 을 써서 해제 (p.36). 직렬 설정은 51171 접근 레지스터로 가져오기/적용 (p.42).","en":"Remote setup is locked by default; unlock via 51000 (2300→0→700→1) (p.36). Serial settings are fetched/applied via access register 51171 (p.42)."},{"ko":"Accura 2750P[C] 등 모터 모듈 데이터는 모듈 ID 별로 10117~ 영역에 있다(p.19) — 여기선 2700M 인입단 계측만 담았다.","en":"Motor-module (Accura 2750P[C] etc.) data lives per module ID from 10117 (p.19); only 2700M incomer metering is included."}],"sources":[{"title":"Accura 2700/2750 Communication Guide","publisher":"Rootech Inc.","edition":{"ko":"Rev 1.40, 2026-08-06 (파일명 Accura_2700_Communication_Guide_Rev1_40_Korean_260806.pdf)","en":"Rev 1.40, 2026-08-06 (file name Accura_2700_Communication_Guide_Rev1_40_Korean_260806.pdf)"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1478&no=0","pages":{"ko":"p.18-22 맵 요약·형식·시스템 정보, p.36, p.42, p.96-99 계측, p.186-191 프로토콜","en":"pp.18-22 map summary, formats, system info, p.36, p.42, pp.96-99 measurements, pp.186-191 protocol"},"checked":"2026-10-22"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"rootech/accura-3300e","manufacturer":{"ko":"루텍","en":"Rootech"},"model":"Accura 3300E","kind":"power-meter","title":{"ko":"루텍 Accura 3300E 디지털 전력 미터","en":"Rootech Accura 3300E digital power meter"},"summary":{"ko":"3상 다기능 전력 미터. RS-485 Modbus RTU, 모든 값은 holding register(FC03)에 있고 32비트 값은 상위 워드 먼저.","en":"3-phase multifunction power meter. RS-485 Modbus RTU; all data in holding registers (FC03), 32-bit values high word first."},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,115200],"parity":"even","stopBits":1,"order":"ABCD","maxRegisters":125,"addressing":"one","notes":[{"ko":"매뉴얼은 레지스터 번호(1 기준)로 적는다 — 통신 주소 = 번호 − 1 (p.12, p.18, p.44 예: 11030 → 2B15h).","en":"Manual lists 1-based register numbers; wire address = number − 1 (p.12, p.18, p.44 example: 11030 → 2B15h)."},{"ko":"32비트(UInt32/Int32/Float32)는 상위 워드가 낮은 주소 — Big-Endian (p.19, p.44 예: 380.2 = 43BEh 1999h).","en":"32-bit values: high word at lower address, big-endian (p.19, p.44 example: 380.2 = 43BEh 1999h)."},{"ko":"출하값 9600 bps·짝수 패리티·정지 1비트·Modbus RTU (p.28). 국번은 범위 1-247 인데 같은 쪽에 Default 0 으로 적혀 있어 출하 국번은 비워 둠 — 장치 화면에서 확인.","en":"Defaults 9600 bps, even parity, 1 stop bit, Modbus RTU (p.28). Address range is 1-247 but the same page says default 0, so factory unit ID is left out — check on the device."},{"ko":"함수 코드는 03·06·16 만 지원 (p.12). 한 번에 읽기 1-125 레지스터 (p.13).","en":"Only FC 03, 06, 16 supported (p.12). Read quantity 1-125 (p.13)."}]},"registers":[{"table":"holding-registers","address":9999,"manualAddress":"10000","type":"u16","name":{"ko":"제품 ID","en":"Product ID"},"access":"r","fc":[3],"description":{"ko":"3300E 는 3301","en":"3301 for Accura 3300E"},"ref":"p.22 System Information"},{"table":"holding-registers","address":10000,"manualAddress":"10001","type":"u32","order":"ABCD","name":{"ko":"일련번호","en":"Serial number"},"access":"r","fc":[3],"ref":"p.22 System Information"},{"table":"holding-registers","address":10013,"manualAddress":"10014","type":"u16","name":{"ko":"펌웨어 버전","en":"Firmware version"},"access":"r","fc":[3],"ref":"p.22 System Information"},{"table":"holding-registers","address":10014,"manualAddress":"10015","type":"u16","name":{"ko":"Modbus 맵 버전","en":"Modbus map version"},"access":"r","fc":[3],"ref":"p.22 System Information"},{"table":"holding-registers","address":10099,"manualAddress":"10100","type":"u16","name":{"ko":"원격 설정 잠금","en":"Remote setup lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제(출하값)","en":"Unlocked (default)"},{"value":1,"ko":"잠금","en":"Locked"}],"description":{"ko":"2300, 0, 700, 1 을 차례로 쓰면 해제, 다른 값을 쓰면 잠금. 전원 재투입 시 해제 상태로 돌아감","en":"Write 2300, 0, 700, 1 in sequence to unlock; any other value locks. Returns to unlocked after power cycle"},"ref":"p.23 Remote Setup Lock"},{"table":"holding-registers","address":10249,"manualAddress":"10250","type":"u16","name":{"ko":"직렬 통신 설정 접근","en":"Serial comm setup access"},"access":"rw","fc":[3,6,16],"description":{"ko":"읽으면 10251-10255 로 현재 설정을 가져오고(bit15=1 이면 성공), 1 을 쓰면 10251-10255 값을 장치에 적용","en":"Read to fetch settings into 10251-10255 (bit 15 = 1 on success); write 1 to apply 10251-10255"},"ref":"p.28 Serial Communication Setup"},{"table":"holding-registers","address":10250,"manualAddress":"10251","type":"u16","name":{"ko":"국번","en":"Device address"},"access":"rw","fc":[3,6,16],"description":{"ko":"범위 1-247. 10250 접근 레지스터로 가져오기/적용","en":"Range 1-247. Fetch/apply via access register 10250"},"ref":"p.28 Serial Communication Setup"},{"table":"holding-registers","address":10251,"manualAddress":"10252","type":"u16","name":{"ko":"통신 속도","en":"Bit rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200","en":"1200"},{"value":1,"ko":"2400","en":"2400"},{"value":2,"ko":"4800","en":"4800"},{"value":3,"ko":"9600 (출하값)","en":"9600 (default)"},{"value":4,"ko":"19200","en":"19200"},{"value":5,"ko":"38400","en":"38400"},{"value":6,"ko":"57600","en":"57600"},{"value":7,"ko":"115200","en":"115200"}],"ref":"p.28 Serial Communication Setup"},{"table":"holding-registers","address":10252,"manualAddress":"10253","type":"u16","name":{"ko":"패리티","en":"Parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수 (출하값)","en":"Even (default)"}],"ref":"p.28 Serial Communication Setup"},{"table":"holding-registers","address":10253,"manualAddress":"10254","type":"u16","name":{"ko":"정지 비트","en":"Stop bits"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트 (출하값)","en":"1 stop bit (default)"},{"value":1,"ko":"2비트","en":"2 stop bits"}],"ref":"p.28 Serial Communication Setup"},{"table":"holding-registers","address":11009,"manualAddress":"11010","type":"u16","name":{"ko":"데이터 유효성","en":"Data validity"},"access":"r","fc":[3],"values":[{"value":0,"ko":"유효하지 않음","en":"Invalid"},{"value":1,"ko":"유효","en":"Valid"}],"description":{"ko":"11011-15209 데이터의 유효성","en":"Validity of data in 11011-15209"},"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11013,"manualAddress":"11014","type":"f32","order":"ABCD","name":{"ko":"A상 상전압","en":"Phase A voltage (L-N)"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11015,"manualAddress":"11016","type":"f32","order":"ABCD","name":{"ko":"B상 상전압","en":"Phase B voltage (L-N)"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11017,"manualAddress":"11018","type":"f32","order":"ABCD","name":{"ko":"C상 상전압","en":"Phase C voltage (L-N)"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11019,"manualAddress":"11020","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average L-N voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11021,"manualAddress":"11022","type":"f32","order":"ABCD","name":{"ko":"A상 전류","en":"Phase A current"},"unit":"A","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11023,"manualAddress":"11024","type":"f32","order":"ABCD","name":{"ko":"B상 전류","en":"Phase B current"},"unit":"A","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11025,"manualAddress":"11026","type":"f32","order":"ABCD","name":{"ko":"C상 전류","en":"Phase C current"},"unit":"A","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11027,"manualAddress":"11028","type":"f32","order":"ABCD","name":{"ko":"평균 전류","en":"Average current"},"unit":"A","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11029,"manualAddress":"11030","type":"f32","order":"ABCD","name":{"ko":"AB 선간전압","en":"Voltage A-B (L-L)"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11031,"manualAddress":"11032","type":"f32","order":"ABCD","name":{"ko":"BC 선간전압","en":"Voltage B-C (L-L)"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11033,"manualAddress":"11034","type":"f32","order":"ABCD","name":{"ko":"CA 선간전압","en":"Voltage C-A (L-L)"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11035,"manualAddress":"11036","type":"f32","order":"ABCD","name":{"ko":"평균 선간전압","en":"Average L-L voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11037,"manualAddress":"11038","type":"f32","order":"ABCD","name":{"ko":"A상 유효전력","en":"Phase A active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11039,"manualAddress":"11040","type":"f32","order":"ABCD","name":{"ko":"B상 유효전력","en":"Phase B active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11041,"manualAddress":"11042","type":"f32","order":"ABCD","name":{"ko":"C상 유효전력","en":"Phase C active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11043,"manualAddress":"11044","type":"f32","order":"ABCD","name":{"ko":"총 유효전력","en":"Total active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11051,"manualAddress":"11052","type":"f32","order":"ABCD","name":{"ko":"총 무효전력","en":"Total reactive power"},"unit":"kVAR","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11059,"manualAddress":"11060","type":"f32","order":"ABCD","name":{"ko":"총 피상전력","en":"Total apparent power"},"unit":"kVA","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11061,"manualAddress":"11062","type":"f32","order":"ABCD","name":{"ko":"A상 역률","en":"Phase A power factor"},"access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11063,"manualAddress":"11064","type":"f32","order":"ABCD","name":{"ko":"B상 역률","en":"Phase B power factor"},"access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11065,"manualAddress":"11066","type":"f32","order":"ABCD","name":{"ko":"C상 역률","en":"Phase C power factor"},"access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11067,"manualAddress":"11068","type":"f32","order":"ABCD","name":{"ko":"총 역률","en":"Total power factor"},"access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11072,"manualAddress":"11073","type":"u16","name":{"ko":"총 역률 위상 상태","en":"Total PF angle status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"유효하지 않음(피상전력 0)","en":"Invalid (apparent power 0)"},{"value":1,"ko":"진상","en":"Lead"},{"value":2,"ko":"지상","en":"Lag"}],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11073,"manualAddress":"11074","type":"s32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Received active energy"},"unit":"kWh","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11075,"manualAddress":"11076","type":"s32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Delivered active energy"},"unit":"kWh","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11081,"manualAddress":"11082","type":"s32","order":"ABCD","name":{"ko":"양의 무효전력량","en":"Positive reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11083,"manualAddress":"11084","type":"s32","order":"ABCD","name":{"ko":"음의 무효전력량","en":"Negative reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11089,"manualAddress":"11090","type":"s32","order":"ABCD","name":{"ko":"피상전력량","en":"Apparent energy"},"unit":"kVAh","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11127,"manualAddress":"11128","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total demand active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11289,"manualAddress":"11290","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":11291,"manualAddress":"11292","type":"f32","order":"ABCD","name":{"ko":"장치 후면 온도","en":"Rear temperature"},"unit":"℃","access":"r","fc":[3],"ref":"p.32-35 Measurement Data"},{"table":"holding-registers","address":65525,"manualAddress":"65526","type":"u16","name":{"ko":"주소·엔디언 시험값","en":"Address/endian test word"},"access":"r","fc":[3],"description":{"ko":"65526-65529 에 4142h, 4344h, 4546h, 4748h 상수. 65527 부터 2워드 읽어 43 44 45 46h 가 나오면 주소·순서 정상","en":"Constants 4142h, 4344h, 4546h, 4748h at 65526-65529; reading 2 words from 65527 should give 43 44 45 46h"},"ref":"p.45 Modbus Test Register Address"}],"notes":[{"ko":"계측표(p.32-35)에는 속성 칸이 없다 — 계측값은 읽기 전용(FC03)으로 적었다.","en":"Measurement table (p.32-35) has no attribute column; measurement values are listed as read-only (FC03)."},{"ko":"계측값은 1초마다 갱신. 11010-12197 을 여러 패킷으로 읽을 때 주소가 줄어드는 패킷에서만 전체를 다시 가져온다(동시성) (p.32).","en":"Data refreshed every 1 s. When reading 11010-12197 in several packets, a full re-fetch happens only on a packet with a lower start address (p.32)."},{"ko":"값은 실제 단위(V·A·kW…)의 Float32 라서 PT/CT 비 배율을 곱할 필요가 없다. 전력량은 Int32 kWh/kVARh/kVAh 정수.","en":"Values are Float32 in engineering units (V, A, kW…), no PT/CT scaling needed. Energies are Int32 in kWh/kVARh/kVAh."},{"ko":"직렬 설정(10251-10254)은 PRW — 10250 을 읽어 가져오고, 값을 쓴 뒤 10250 에 1 을 써야 적용된다 (p.28).","en":"Serial settings (10251-10254) are PRW: read 10250 to fetch, write values, then write 1 to 10250 to apply (p.28)."},{"ko":"Rev 2.12(2026-10-22)를 Rev 2.11 과 대조했다 — 이 파일에 넣은 레지스터의 번호·형식·단위·읽기/쓰기는 그대로다. 새 판의 변경은 계측표 이름 표기·오타(11078 단위 칸 kWh 추가 등)와 시스템 정보 10017~10018 항목 이름, 쪽 번호(계측 p.32-35, 3장 p.44-45)다.","en":"Rev 2.12 (2026-10-22) was compared with Rev 2.11: register numbers, types, units and access for the registers in this file are unchanged. The new edition fixes measurement-table names and typos (e.g. kWh added to the 11078 unit column), renames system-information items 10017-10018, and shifts pages (measurements pp.32-35, chapter 3 pp.44-45)."}],"sources":[{"title":"Accura 3300E Communication Guide [Korean]","publisher":"Rootech Inc.","edition":{"ko":"Revision 2.12, 2026-10-22","en":"Revision 2.12, 2026-10-22"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1499&no=0","pages":{"ko":"p.12-13 함수 코드, p.18-19 맵 개요·형식, p.22-23, p.28, p.32-35 계측, p.44-45 주소·엔디언","en":"pp.12-13 function codes, pp.18-19 map overview and formats, pp.22-23, p.28, pp.32-35 measurements, pp.44-45 addresses and endianness"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"rootech/accura-3500","manufacturer":{"ko":"루텍","en":"Rootech"},"model":"Accura 3500","models":["Accura 3500","Accura 3550"],"kind":"power-meter","title":{"ko":"루텍 Accura 3500/3550 디지털 전력 미터","en":"Rootech Accura 3500/3550 digital power meter"},"summary":{"ko":"3상 다기능 전력 미터(확장 IO 모듈 연결 가능). Modbus TCP·RTU, 모든 값은 holding register(FC03), 32비트는 상위 워드 먼저. 계측값은 aggregation 버퍼에서 19911 을 읽어 가져온(fetch) 뒤 읽는다. 3550 도 본체 계측 맵이 같다.","en":"3-phase multifunction power meter with optional IO modules. Modbus TCP/RTU, all data in holding registers (FC03), 32-bit high word first. Measurements come from aggregation buffers: read 19911 to fetch, then read. The Accura 3550 uses the same meter map."},"protocols":["rtu","tcp"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,115200],"parity":"even","stopBits":1,"tcpPort":502,"order":"ABCD","maxRegisters":125,"addressing":"one","notes":[{"ko":"매뉴얼은 레지스터 번호(1 기준) — 통신 주소 = 번호 − 1. 숫자 프레임 예: p.115 «01 03 0000 0003» 이 레지스터 1-3 을 읽는다, p.118 AB 선간전압 20011 → 시작 주소 4E2Ah, p.121 12901 → 3264h (p.13, p.110).","en":"Manual uses 1-based register numbers; wire address = number − 1. Numeric frame examples: p.115 «01 03 0000 0003» reads registers 1-3, p.118 Vab register 20011 → start address 4E2Ah, p.121 register 12901 → 3264h (p.13, p.110)."},{"ko":"32비트(UInt32/Int32/Float32)는 상위 워드가 낮은 주소 — Big-endian (p.14, p.119 예: 380.2 = 43BEh 199Ah).","en":"32-bit values: high word at lower address, big-endian (p.14, p.119 example: 380.2 = 43BEh 199Ah)."},{"ko":"RS-485 출하값 9600 bps·짝수 패리티·정지 1비트 (p.27). 국번 범위 0-247 에 Default 0 으로 적혀 있어 출하 국번은 비워 둠.","en":"RS-485 defaults 9600 bps, even parity, 1 stop bit (p.27). Address range 0-247 with default 0, so factory unit ID is left out."},{"ko":"함수 코드 03·06·16, 사용자 정의 101(65h, TCP 전용). 읽기 수량 표준 1-125(장치는 250 까지, 128 이상은 byte count 넘침), 쓰기 1-123. Modbus TCP 포트 502, Unit ID 1 고정, 동시 접속 20(TCP 19, RTU 1), 요청 없이 10분이면 TCP 끊음 (p.106-110, p.112).","en":"FC 03, 06, 16 plus user-defined 101 (65h, TCP only). Read quantity 1-125 (device allows 250, byte count overflows from 128), write 1-123. Modbus TCP port 502, unit ID fixed at 1, 20 connections (19 TCP, 1 RTU), TCP closed after 10 min idle (p.106-110, p.112)."}]},"registers":[{"table":"holding-registers","address":10000,"manualAddress":"10001","type":"u16","name":{"ko":"제품 ID","en":"Product ID"},"access":"r","fc":[3],"description":{"ko":"Accura 3500 = 3500, Accura 3550 = 3550","en":"3500 for Accura 3500, 3550 for Accura 3550"},"ref":"p.15 System Information"},{"table":"holding-registers","address":10002,"manualAddress":"10003","type":"u32","order":"ABCD","name":{"ko":"일련번호","en":"Serial number"},"access":"r","fc":[3],"ref":"p.15 System Information"},{"table":"holding-registers","address":10007,"manualAddress":"10008","type":"u16","name":{"ko":"소프트웨어 주 버전","en":"Major application version"},"access":"r","fc":[3],"ref":"p.15 System Information"},{"table":"holding-registers","address":10008,"manualAddress":"10009","type":"u16","name":{"ko":"소프트웨어 부 버전","en":"Minor application version"},"access":"r","fc":[3],"ref":"p.15 System Information"},{"table":"holding-registers","address":10009,"manualAddress":"10010","type":"u16","name":{"ko":"소프트웨어 개정 버전","en":"Application revision"},"access":"r","fc":[3],"ref":"p.15 System Information"},{"table":"holding-registers","address":12900,"manualAddress":"12901","type":"u16","name":{"ko":"원격 설정 잠금","en":"Remote setup lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제","en":"Unlocked"},{"value":1,"ko":"잠금","en":"Locked"}],"description":{"ko":"2300 → 0 → 700 → 1 을 차례로 쓰면 해제, 아무 값이나 쓰면 잠금. 접속마다 따로, 전원을 끄면 다시 잠김.","en":"Write 2300 → 0 → 700 → 1 to unlock; any other write locks. Per connection; relocks at power-off."},"ref":"p.19 Remote Setup Unlock"},{"table":"holding-registers","address":13700,"manualAddress":"13701","type":"u16","name":{"ko":"RS-485 설정 접근","en":"Access for RS-485 setup"},"access":"rw","fc":[3,6,16],"description":{"ko":"읽으면 장치 설정을 13702~13705 로 가져온다(성공 시 Bit 15 = 1). 1 을 쓰면 13702~13705 값을 장치에 적용.","en":"Read fetches device settings into 13702-13705 (bit 15 = 1 on success); write 1 to apply 13702-13705."},"ref":"p.27 RS-485 Setup"},{"table":"holding-registers","address":13701,"manualAddress":"13702","type":"u16","name":{"ko":"RS-485 국번","en":"RS-485 device address"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":247},"ref":"p.27 RS-485 Setup"},{"table":"holding-registers","address":13702,"manualAddress":"13703","type":"u16","name":{"ko":"RS-485 통신 속도","en":"RS-485 bit rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200 bps","en":"1200 bps"},{"value":1,"ko":"2400 bps","en":"2400 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"9600 bps","en":"9600 bps"},{"value":4,"ko":"19200 bps","en":"19200 bps"},{"value":5,"ko":"38400 bps","en":"38400 bps"},{"value":6,"ko":"57600 bps","en":"57600 bps"},{"value":7,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.27 RS-485 Setup"},{"table":"holding-registers","address":13703,"manualAddress":"13704","type":"u16","name":{"ko":"RS-485 패리티","en":"RS-485 parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수","en":"Even"}],"ref":"p.27 RS-485 Setup"},{"table":"holding-registers","address":13704,"manualAddress":"13705","type":"u16","name":{"ko":"RS-485 정지 비트","en":"RS-485 stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 stop bit"},{"value":1,"ko":"2비트","en":"2 stop bits"}],"ref":"p.27 RS-485 Setup"},{"table":"holding-registers","address":19900,"manualAddress":"19901","type":"u16","name":{"ko":"Aggregation 선택","en":"Aggregation selection"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0.2초","en":"0.2 s"},{"value":1,"ko":"1초 (기본)","en":"1 s (default)"},{"value":2,"ko":"5초","en":"5 s"},{"value":3,"ko":"1분","en":"1 min"},{"value":4,"ko":"5분","en":"5 min"},{"value":5,"ko":"1시간","en":"1 h"},{"value":6,"ko":"6시간","en":"6 h"},{"value":7,"ko":"1일","en":"1 day"},{"value":255,"ko":"Max/Min (리셋 이후)","en":"Max/Min since reset"}],"ref":"p.58 Aggregation Selection"},{"table":"holding-registers","address":19901,"manualAddress":"19902","type":"u16","name":{"ko":"Index 갱신 방식","en":"Index selection update mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"고정","en":"Fixed"},{"value":1,"ko":"최신","en":"Newest"},{"value":2,"ko":"자동 증가","en":"Auto increment"}],"description":{"ko":"19911 을 읽어 가져올 때 19904 를 어떻게 바꿀지. 최신(1)이면 늘 최신 데이터를 가져온다(p.123: 기본은 최신 index 자동).","en":"How 19904 changes when 19911 is read. Newest (1) always fetches the latest data (p.123: newest index by default)."},"ref":"p.59 Index Selection"},{"table":"holding-registers","address":19903,"manualAddress":"19904","type":"u16","name":{"ko":"Index 선택","en":"Index selection"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.59 Index Selection"},{"table":"holding-registers","address":19905,"manualAddress":"19906","type":"u16","name":{"ko":"최신 index","en":"Newest index"},"access":"r","fc":[3],"ref":"p.59 Index Selection"},{"table":"holding-registers","address":19910,"manualAddress":"19911","type":"u16","name":{"ko":"데이터 가져오기(fetch)","en":"Data fetch"},"access":"r","fc":[3],"values":[{"value":0,"ko":"실패","en":"Fetch failed"},{"value":1,"ko":"성공","en":"Fetch succeeded"}],"description":{"ko":"읽으면 고른 aggregation·index 의 데이터를 19914~48000 에 채운다. 접속마다 따로.","en":"Reading fetches the selected aggregation/index into 19914-48000. Per connection."},"ref":"p.60 Data Fetch"},{"table":"holding-registers","address":19912,"manualAddress":"19913","type":"u16","name":{"ko":"가져온 데이터의 index","en":"Index of fetched data"},"access":"r","fc":[3],"ref":"p.60 Data Fetch"},{"table":"holding-registers","address":19929,"manualAddress":"19930","type":"s16","name":{"ko":"본체 계측 데이터 유효성","en":"Validity of meter measurement data"},"access":"r","fc":[3],"values":[{"value":-1,"ko":"유효하지 않음","en":"Invalid"},{"value":0,"ko":"유효(본체 데이터)","en":"Valid (meter data)"}],"description":{"ko":"p.126 표에는 UInt16 로 적혀 있으나 값이 -1/0 이라 p.61 대로 Int16 으로 적음.","en":"p.126 lists UInt16, but values are -1/0, so Int16 per p.61."},"ref":"p.61 Measurement Header"},{"table":"holding-registers","address":20000,"manualAddress":"20001","type":"f32","order":"ABCD","name":{"ko":"A상 상전압","en":"Voltage Van"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20002,"manualAddress":"20003","type":"f32","order":"ABCD","name":{"ko":"B상 상전압","en":"Voltage Vbn"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20004,"manualAddress":"20005","type":"f32","order":"ABCD","name":{"ko":"C상 상전압","en":"Voltage Vcn"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20006,"manualAddress":"20007","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average phase voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20010,"manualAddress":"20011","type":"f32","order":"ABCD","name":{"ko":"AB 선간전압","en":"Voltage Vab"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20012,"manualAddress":"20013","type":"f32","order":"ABCD","name":{"ko":"BC 선간전압","en":"Voltage Vbc"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20014,"manualAddress":"20015","type":"f32","order":"ABCD","name":{"ko":"CA 선간전압","en":"Voltage Vca"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20016,"manualAddress":"20017","type":"f32","order":"ABCD","name":{"ko":"평균 선간전압","en":"Average line-to-line voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20018,"manualAddress":"20019","type":"f32","order":"ABCD","name":{"ko":"A상 전류","en":"Current Ia"},"unit":"A","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20020,"manualAddress":"20021","type":"f32","order":"ABCD","name":{"ko":"B상 전류","en":"Current Ib"},"unit":"A","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20022,"manualAddress":"20023","type":"f32","order":"ABCD","name":{"ko":"C상 전류","en":"Current Ic"},"unit":"A","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20024,"manualAddress":"20025","type":"f32","order":"ABCD","name":{"ko":"평균 전류","en":"Average current"},"unit":"A","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20056,"manualAddress":"20057","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20058,"manualAddress":"20059","type":"f32","order":"ABCD","name":{"ko":"A상 전압 THD","en":"Voltage THD phase A"},"unit":"%","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20060,"manualAddress":"20061","type":"f32","order":"ABCD","name":{"ko":"B상 전압 THD","en":"Voltage THD phase B"},"unit":"%","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20062,"manualAddress":"20063","type":"f32","order":"ABCD","name":{"ko":"C상 전압 THD","en":"Voltage THD phase C"},"unit":"%","access":"r","fc":[3],"ref":"p.62 Measurement Data"},{"table":"holding-registers","address":20070,"manualAddress":"20071","type":"f32","order":"ABCD","name":{"ko":"A상 전류 THD","en":"Current THD phase A"},"unit":"%","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20072,"manualAddress":"20073","type":"f32","order":"ABCD","name":{"ko":"B상 전류 THD","en":"Current THD phase B"},"unit":"%","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20074,"manualAddress":"20075","type":"f32","order":"ABCD","name":{"ko":"C상 전류 THD","en":"Current THD phase C"},"unit":"%","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20094,"manualAddress":"20095","type":"f32","order":"ABCD","name":{"ko":"A상 유효전력","en":"Active power phase A"},"unit":"kW","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20096,"manualAddress":"20097","type":"f32","order":"ABCD","name":{"ko":"B상 유효전력","en":"Active power phase B"},"unit":"kW","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20098,"manualAddress":"20099","type":"f32","order":"ABCD","name":{"ko":"C상 유효전력","en":"Active power phase C"},"unit":"kW","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20100,"manualAddress":"20101","type":"f32","order":"ABCD","name":{"ko":"총 유효전력","en":"Total active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20108,"manualAddress":"20109","type":"f32","order":"ABCD","name":{"ko":"총 무효전력","en":"Total reactive power"},"unit":"kVAR","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20116,"manualAddress":"20117","type":"f32","order":"ABCD","name":{"ko":"총 피상전력","en":"Total apparent power"},"unit":"kVA","access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20118,"manualAddress":"20119","type":"f32","order":"ABCD","name":{"ko":"A상 역률","en":"Power factor phase A"},"access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20120,"manualAddress":"20121","type":"f32","order":"ABCD","name":{"ko":"B상 역률","en":"Power factor phase B"},"access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20122,"manualAddress":"20123","type":"f32","order":"ABCD","name":{"ko":"C상 역률","en":"Power factor phase C"},"access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20124,"manualAddress":"20125","type":"f32","order":"ABCD","name":{"ko":"총 역률","en":"Total power factor"},"access":"r","fc":[3],"ref":"p.63 Measurement Data"},{"table":"holding-registers","address":20137,"manualAddress":"20138","type":"u16","name":{"ko":"총 역률 진상·지상 상태","en":"Total power factor lead/lag status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"진상","en":"Lead"},{"value":2,"ko":"지상","en":"Lag"},{"value":3,"ko":"무부하(피상전력 0)","en":"No load (apparent power 0)"}],"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20138,"manualAddress":"20139","type":"f32","order":"ABCD","name":{"ko":"상전압 불평형률","en":"Voltage unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20156,"manualAddress":"20157","type":"f32","order":"ABCD","name":{"ko":"전류 불평형률","en":"Current unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20168,"manualAddress":"20169","type":"f32","order":"ABCD","name":{"ko":"장치 온도","en":"Device temperature"},"unit":"℃","access":"r","fc":[3],"description":{"ko":"온도 단위 설정(Locale)이 화씨면 ℉ 로 나온다.","en":"Reported in ℉ when the Locale temperature unit is Fahrenheit."},"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20250,"manualAddress":"20251","type":"u32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Received active energy"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"단위는 전력량 단위 설정을 따른다(기본 kWh, Wh 로 바꿀 수 있음).","en":"Unit follows the energy-unit setting (default kWh, can be Wh)."},"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20252,"manualAddress":"20253","type":"u32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Delivered active energy"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"단위는 전력량 단위 설정을 따른다(기본 kWh, Wh 로 바꿀 수 있음).","en":"Unit follows the energy-unit setting (default kWh, can be Wh)."},"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20256,"manualAddress":"20257","type":"s32","order":"ABCD","name":{"ko":"유효전력량 차(수전 − 송전)","en":"Net active energy (received − delivered)"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"단위는 전력량 단위 설정을 따른다(기본 kWh, Wh 로 바꿀 수 있음).","en":"Unit follows the energy-unit setting (default kWh, can be Wh)."},"ref":"p.64 Measurement Data"},{"table":"holding-registers","address":20266,"manualAddress":"20267","type":"u32","order":"ABCD","name":{"ko":"양의 무효전력량","en":"Positive reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.65 Measurement Data"},{"table":"holding-registers","address":20268,"manualAddress":"20269","type":"u32","order":"ABCD","name":{"ko":"음의 무효전력량","en":"Negative reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.65 Measurement Data"},{"table":"holding-registers","address":20274,"manualAddress":"20275","type":"u32","order":"ABCD","name":{"ko":"피상전력량","en":"Apparent energy"},"unit":"kVAh","access":"r","fc":[3],"ref":"p.65 Measurement Data"},{"table":"holding-registers","address":20496,"manualAddress":"20497","type":"f32","order":"ABCD","name":{"ko":"평균 전류 디맨드","en":"Average demand current"},"unit":"A","access":"r","fc":[3],"ref":"p.66 Measurement Data"},{"table":"holding-registers","address":20504,"manualAddress":"20505","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total demand active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.66 Measurement Data"},{"table":"holding-registers","address":20590,"manualAddress":"20591","type":"u16","name":{"ko":"전력량 단위","en":"Energy unit"},"access":"r","fc":[3],"values":[{"value":0,"ko":"kWh","en":"kWh"},{"value":1,"ko":"Wh","en":"Wh"}],"description":{"ko":"유효전력량 단위 설정(Locale)을 따른다 — 1 이면 유효전력량이 Wh.","en":"Follows the Locale energy-unit setting; 1 means active energy is in Wh."},"ref":"p.66 Measurement Data"}],"notes":[{"ko":"계측값은 aggregation 버퍼에 있다 — 19901 로 구간(기본 1초)을 고르고 19911 을 읽어 가져온 뒤 20001~ 을 읽는다. 최신 index 모드면 가져오기를 생략할 수 있다. 선택·index 는 접속마다 따로 (p.56-60, p.109, p.123-126).","en":"Measurements live in aggregation buffers: select the interval with 19901 (default 1 s), read 19911 to fetch, then read 20001-. In newest-index mode the fetch may be skipped. Selection/index are per connection (p.56-60, p.109, p.123-126)."},{"ko":"포트마다 기본 레지스터 맵을 고를 수 있다(65534: 0 Accura 3500, 1 RTM 200) — 이 파일은 0(새 맵) 기준. 옛 맵은 Appendix F (p.29, p.127-).","en":"Each port can use a different default register map (65534: 0 Accura 3500, 1 RTM 200); this file follows map 0. The old map is in Appendix F (p.29, p.127-)."},{"ko":"값은 실제 단위 Float32(V·A·kW…), 전력량은 UInt32(차이 값만 Int32) kWh 등 — PT/CT 배율을 따로 곱하지 않는다. 유효전력량 단위는 13024(Locale)로 Wh 로 바꿀 수 있고 20591 로 확인 (p.44, p.64, p.66).","en":"Values are Float32 in engineering units; energies UInt32 (net values Int32) in kWh etc., no PT/CT scaling needed. Active-energy unit can be switched to Wh with 13024 (Locale); check 20591 (p.44, p.64, p.66)."},{"ko":"원격 설정은 기본 잠금 — 쓰기 전에 12901 에 2300→0→700→1 (p.19, p.121). 직렬 설정은 13701 접근 레지스터로 가져오기/적용 (p.27).","en":"Remote setup is locked by default; unlock with 2300→0→700→1 to 12901 (p.19, p.121). Serial settings are fetched/applied via access register 13701 (p.27)."},{"ko":"Accura 3550 Communication Guide(Rev 2.20)도 본체 계측 맵·주소·형식이 같다(계측표 쪽이 +3: p.65-69, 프레임 예 p.119·p.122). 제품 ID 만 3550. 여기 적은 계측 레지스터는 두 문서에서 하나씩 대조함.","en":"The Accura 3550 Communication Guide (Rev 2.20) has the same meter map, addresses and formats (measurement pages +3: pp.65-69, frame examples p.119 and p.122); only the product ID differs (3550). Each measurement register here was checked in both guides."}],"sources":[{"title":"Accura 3500 Communication Guide","publisher":"Rootech Inc.","edition":{"ko":"Revision 2.20, 2026-02-12 (파일명 Accura_3500_Communication_Guide_Rev2_20_Korean_260212.pdf)","en":"Revision 2.20, 2026-02-12 (file name Accura_3500_Communication_Guide_Rev2_20_Korean_260212.pdf)"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1445&no=0","pages":{"ko":"p.13-15 맵 요약·형식·시스템 정보, p.19, p.27, p.29, p.56-66 계측, p.106-115 프로토콜·RTU 예, p.118-126 주소·엔디언·수집 절차","en":"pp.13-15 map summary, formats, system info, p.19, p.27, p.29, pp.56-66 measurements, pp.106-115 protocol and RTU example, pp.118-126 addressing, endian, collection"},"checked":"2026-10-23"},{"title":"Accura 3550 Communication Guide","publisher":"Rootech Inc.","edition":{"ko":"Revision 2.20, 2026-02-12 (파일명 Accura_3550_Communication_Guide_Rev2_20_Korean_260212.pdf)","en":"Revision 2.20, 2026-02-12 (file name Accura_3550_Communication_Guide_Rev2_20_Korean_260212.pdf)"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1446&no=0","pages":{"ko":"p.13-15 맵 요약·시스템 정보, p.27, p.61-69 계측, p.119, p.122-125 주소·엔디언 예","en":"pp.13-15 map summary and system info, p.27, pp.61-69 measurements, p.119, pp.122-125 addressing and endian examples"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"rootech/accura-3700","manufacturer":{"ko":"루텍","en":"Rootech"},"model":"Accura 3700","kind":"power-meter","title":{"ko":"루텍 Accura 3700 전력 품질 미터","en":"Rootech Accura 3700 power quality meter"},"summary":{"ko":"3상 전력 품질 미터(확장 IO 모듈 연결 가능). Modbus TCP·RTU, 모든 값은 holding register(FC03), 32비트는 상위 워드 먼저. 계측값은 aggregation 버퍼에 있고, 9911 을 읽어 가져온(fetch) 뒤 읽는다(기본 최신 모드면 생략 가능).","en":"3-phase power quality meter with optional IO modules. Modbus TCP/RTU, all data in holding registers (FC03), 32-bit high word first. Measurements come from aggregation buffers: read 9911 to fetch, then read (may be skipped in the default newest mode)."},"protocols":["rtu","tcp"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,115200],"parity":"even","stopBits":1,"tcpPort":502,"order":"ABCD","maxRegisters":125,"addressing":"one","notes":[{"ko":"매뉴얼은 레지스터 번호(1 기준) — 통신 주소 = 번호 − 1. 숫자 프레임 예: p.176 «01 03 0000 0003» 이 레지스터 1-3 을 읽는다(응답 첫 값 0E75h = 3701 = 레지스터 1 제품 ID), p.179 AB 선간전압 10011 → 시작 주소 271Ah, p.182 2901 → 0B54h (p.14, p.170).","en":"Manual uses 1-based register numbers; wire address = number − 1. Numeric frame examples: p.176 «01 03 0000 0003» reads registers 1-3 (first response value 0E75h = 3701 = product ID in register 1), p.179 Vab register 10011 → start address 271Ah, p.182 register 2901 → 0B54h (p.14, p.170)."},{"ko":"32비트(UInt32/Int32/Float32)는 상위 워드가 낮은 주소 — Big-endian (p.15, p.180 예: 380.2 = 43BEh 1999h).","en":"32-bit values: high word at lower address, big-endian (p.15, p.180 example: 380.2 = 43BEh 1999h)."},{"ko":"RS-485 출하값 9600 bps·짝수 패리티·정지 1비트 (p.37). 국번 범위 0-247 에 Default 0 으로 적혀 있어 출하 국번은 비워 둠.","en":"RS-485 defaults 9600 bps, even parity, 1 stop bit (p.37). Address range 0-247 with default 0, so factory unit ID is left out."},{"ko":"함수 코드 03·06·16, 사용자 정의 101(65h, TCP 전용). 읽기 수량 표준 1-125(장치는 250 까지), 쓰기 1-123. Modbus TCP 포트 502, Unit ID 1 고정, 동시 접속 20(TCP 19, RTU 1) (p.165-172).","en":"FC 03, 06, 16 plus user-defined 101 (65h, TCP only). Read quantity 1-125 (device allows 250), write 1-123. Modbus TCP port 502, unit ID fixed at 1, 20 connections (19 TCP, 1 RTU) (p.165-172)."}]},"registers":[{"table":"holding-registers","address":0,"manualAddress":"1","type":"u16","name":{"ko":"제품 ID","en":"Product ID"},"access":"r","fc":[3],"description":{"ko":"3700 은 3701","en":"3701 for Accura 3700"},"ref":"p.16 System Information"},{"table":"holding-registers","address":2,"manualAddress":"3","type":"u32","order":"ABCD","name":{"ko":"일련번호","en":"Serial number"},"access":"r","fc":[3],"ref":"p.16 System Information"},{"table":"holding-registers","address":7,"manualAddress":"8","type":"u16","name":{"ko":"소프트웨어 주 버전","en":"Application major version"},"access":"r","fc":[3],"ref":"p.16 System Information"},{"table":"holding-registers","address":8,"manualAddress":"9","type":"u16","name":{"ko":"소프트웨어 부 버전","en":"Application minor version"},"access":"r","fc":[3],"ref":"p.16 System Information"},{"table":"holding-registers","address":9,"manualAddress":"10","type":"u16","name":{"ko":"소프트웨어 개정 버전","en":"Application revision"},"access":"r","fc":[3],"ref":"p.16 System Information"},{"table":"holding-registers","address":2900,"manualAddress":"2901","type":"u16","name":{"ko":"원격 설정 잠금","en":"Remote setup lock"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"잠금 해제","en":"Unlocked"},{"value":1,"ko":"잠금","en":"Locked"}],"description":{"ko":"2300 → 0 → 700 → 1 을 차례로 쓰면 해제, 아무 값이나 쓰면 잠금. 접속마다 따로, 전원을 끄면 다시 잠김.","en":"Write 2300 → 0 → 700 → 1 to unlock; any other write locks. Per connection; relocks at power-off."},"ref":"p.21 Remote Setup Unlock"},{"table":"holding-registers","address":3700,"manualAddress":"3701","type":"u16","name":{"ko":"RS-485 설정 접근","en":"Access for RS-485 setup"},"access":"rw","fc":[3,6,16],"description":{"ko":"읽으면 장치 설정을 3702~3705 로 가져온다(성공 시 Bit 15 = 1). 1 을 쓰면 3702~3705 값을 장치에 적용.","en":"Read fetches device settings into 3702-3705 (bit 15 = 1 on success); write 1 to apply 3702-3705."},"ref":"p.37 RS-485 Setup"},{"table":"holding-registers","address":3701,"manualAddress":"3702","type":"u16","name":{"ko":"RS-485 국번","en":"RS-485 device address"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":247},"ref":"p.37 RS-485 Setup"},{"table":"holding-registers","address":3702,"manualAddress":"3703","type":"u16","name":{"ko":"RS-485 통신 속도","en":"RS-485 bit rate"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1200 bps","en":"1200 bps"},{"value":1,"ko":"2400 bps","en":"2400 bps"},{"value":2,"ko":"4800 bps","en":"4800 bps"},{"value":3,"ko":"9600 bps","en":"9600 bps"},{"value":4,"ko":"19200 bps","en":"19200 bps"},{"value":5,"ko":"38400 bps","en":"38400 bps"},{"value":6,"ko":"57600 bps","en":"57600 bps"},{"value":7,"ko":"115200 bps","en":"115200 bps"}],"ref":"p.37 RS-485 Setup"},{"table":"holding-registers","address":3703,"manualAddress":"3704","type":"u16","name":{"ko":"RS-485 패리티","en":"RS-485 parity"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"홀수","en":"Odd"},{"value":2,"ko":"짝수","en":"Even"}],"ref":"p.37 RS-485 Setup"},{"table":"holding-registers","address":3704,"manualAddress":"3705","type":"u16","name":{"ko":"RS-485 정지 비트","en":"RS-485 stop bit"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"1비트","en":"1 stop bit"},{"value":1,"ko":"2비트","en":"2 stop bits"}],"ref":"p.37 RS-485 Setup"},{"table":"holding-registers","address":9900,"manualAddress":"9901","type":"u16","name":{"ko":"Aggregation 선택","en":"Aggregation selection"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"0.2초","en":"0.2 s"},{"value":1,"ko":"1초 (기본)","en":"1 s (default)"},{"value":2,"ko":"5초","en":"5 s"},{"value":3,"ko":"1분","en":"1 min"},{"value":4,"ko":"5분","en":"5 min"},{"value":5,"ko":"1시간","en":"1 h"},{"value":6,"ko":"6시간","en":"6 h"},{"value":11,"ko":"사용자 11","en":"User-defined 11"},{"value":12,"ko":"사용자 12","en":"User-defined 12"},{"value":13,"ko":"사용자 13","en":"User-defined 13"},{"value":14,"ko":"사용자 14","en":"User-defined 14"},{"value":15,"ko":"사용자 15","en":"User-defined 15"},{"value":255,"ko":"Max/Min (리셋 이후)","en":"Max/Min since reset"}],"ref":"p.91 Aggregation Selection"},{"table":"holding-registers","address":9901,"manualAddress":"9902","type":"u16","name":{"ko":"Index 갱신 방식","en":"Index update mode"},"access":"rw","fc":[3,6,16],"values":[{"value":0,"ko":"고정","en":"Fixed"},{"value":1,"ko":"최신","en":"Newest"},{"value":2,"ko":"자동 증가","en":"Auto increment"}],"description":{"ko":"9911 을 읽어 가져올 때 9904 를 어떻게 바꿀지. 기본은 최신(1) — 이때 계측은 가져오기를 생략할 수 있다(p.184).","en":"How 9904 changes when 9911 is read. Default is Newest (1); then the fetch may be skipped for measurements (p.184)."},"ref":"p.92 Measurement Data Summary"},{"table":"holding-registers","address":9903,"manualAddress":"9904","type":"u16","name":{"ko":"Index 선택","en":"Index selection"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":9999},"ref":"p.92 Measurement Data Summary"},{"table":"holding-registers","address":9910,"manualAddress":"9911","type":"u16","name":{"ko":"데이터 가져오기(fetch)","en":"Data fetch"},"access":"r","fc":[3],"values":[{"value":0,"ko":"실패","en":"Fetch failed"},{"value":1,"ko":"성공","en":"Fetch succeeded"}],"description":{"ko":"읽으면 고른 aggregation·index 의 데이터를 9914~38000 에 채운다. 접속마다 따로.","en":"Reading fetches the selected aggregation/index into 9914-38000. Per connection."},"ref":"p.93 Data Fetch"},{"table":"holding-registers","address":9912,"manualAddress":"9913","type":"u16","name":{"ko":"가져온 데이터의 index","en":"Index of fetched data"},"access":"r","fc":[3],"ref":"p.93 Data Fetch"},{"table":"holding-registers","address":9929,"manualAddress":"9930","type":"s16","name":{"ko":"본체 계측 데이터 유효성","en":"Validity of meter measurement data"},"access":"r","fc":[3],"values":[{"value":-1,"ko":"유효하지 않음","en":"Invalid"},{"value":0,"ko":"유효(Accura 3700)","en":"Valid (Accura 3700)"}],"description":{"ko":"p.188 표에는 UInt16 로 적혀 있으나 값이 -1/0 이라 p.94 대로 Int16 으로 적음.","en":"p.188 lists UInt16, but values are -1/0, so Int16 per p.94."},"ref":"p.94 Measurement Header"},{"table":"holding-registers","address":10000,"manualAddress":"10001","type":"f32","order":"ABCD","name":{"ko":"A상 상전압","en":"Voltage Van"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10002,"manualAddress":"10003","type":"f32","order":"ABCD","name":{"ko":"B상 상전압","en":"Voltage Vbn"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10004,"manualAddress":"10005","type":"f32","order":"ABCD","name":{"ko":"C상 상전압","en":"Voltage Vcn"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10006,"manualAddress":"10007","type":"f32","order":"ABCD","name":{"ko":"평균 상전압","en":"Average phase voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10010,"manualAddress":"10011","type":"f32","order":"ABCD","name":{"ko":"AB 선간전압","en":"Voltage Vab"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10012,"manualAddress":"10013","type":"f32","order":"ABCD","name":{"ko":"BC 선간전압","en":"Voltage Vbc"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10014,"manualAddress":"10015","type":"f32","order":"ABCD","name":{"ko":"CA 선간전압","en":"Voltage Vca"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10016,"manualAddress":"10017","type":"f32","order":"ABCD","name":{"ko":"평균 선간전압","en":"Average line-to-line voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10018,"manualAddress":"10019","type":"f32","order":"ABCD","name":{"ko":"A상 전류","en":"Current Ia"},"unit":"A","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10020,"manualAddress":"10021","type":"f32","order":"ABCD","name":{"ko":"B상 전류","en":"Current Ib"},"unit":"A","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10022,"manualAddress":"10023","type":"f32","order":"ABCD","name":{"ko":"C상 전류","en":"Current Ic"},"unit":"A","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10024,"manualAddress":"10025","type":"f32","order":"ABCD","name":{"ko":"평균 전류","en":"Average current"},"unit":"A","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10056,"manualAddress":"10057","type":"f32","order":"ABCD","name":{"ko":"주파수","en":"Frequency"},"unit":"Hz","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10058,"manualAddress":"10059","type":"f32","order":"ABCD","name":{"ko":"A상 전압 THD","en":"Voltage THD phase A"},"unit":"%","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10060,"manualAddress":"10061","type":"f32","order":"ABCD","name":{"ko":"B상 전압 THD","en":"Voltage THD phase B"},"unit":"%","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10062,"manualAddress":"10063","type":"f32","order":"ABCD","name":{"ko":"C상 전압 THD","en":"Voltage THD phase C"},"unit":"%","access":"r","fc":[3],"ref":"p.96 Measurement Data"},{"table":"holding-registers","address":10070,"manualAddress":"10071","type":"f32","order":"ABCD","name":{"ko":"A상 전류 THD","en":"Current THD phase A"},"unit":"%","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10072,"manualAddress":"10073","type":"f32","order":"ABCD","name":{"ko":"B상 전류 THD","en":"Current THD phase B"},"unit":"%","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10074,"manualAddress":"10075","type":"f32","order":"ABCD","name":{"ko":"C상 전류 THD","en":"Current THD phase C"},"unit":"%","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10094,"manualAddress":"10095","type":"f32","order":"ABCD","name":{"ko":"A상 유효전력","en":"Active power phase A"},"unit":"kW","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10096,"manualAddress":"10097","type":"f32","order":"ABCD","name":{"ko":"B상 유효전력","en":"Active power phase B"},"unit":"kW","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10098,"manualAddress":"10099","type":"f32","order":"ABCD","name":{"ko":"C상 유효전력","en":"Active power phase C"},"unit":"kW","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10100,"manualAddress":"10101","type":"f32","order":"ABCD","name":{"ko":"총 유효전력","en":"Total active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10108,"manualAddress":"10109","type":"f32","order":"ABCD","name":{"ko":"총 무효전력","en":"Total reactive power"},"unit":"kVAR","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10116,"manualAddress":"10117","type":"f32","order":"ABCD","name":{"ko":"총 피상전력","en":"Total apparent power"},"unit":"kVA","access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10118,"manualAddress":"10119","type":"f32","order":"ABCD","name":{"ko":"A상 역률","en":"Power factor phase A"},"access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10120,"manualAddress":"10121","type":"f32","order":"ABCD","name":{"ko":"B상 역률","en":"Power factor phase B"},"access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10122,"manualAddress":"10123","type":"f32","order":"ABCD","name":{"ko":"C상 역률","en":"Power factor phase C"},"access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10124,"manualAddress":"10125","type":"f32","order":"ABCD","name":{"ko":"총 역률","en":"Total power factor"},"access":"r","fc":[3],"ref":"p.97 Measurement Data"},{"table":"holding-registers","address":10137,"manualAddress":"10138","type":"u16","name":{"ko":"총 역률 진상·지상 상태","en":"Total power factor lead/lag status"},"access":"r","fc":[3],"values":[{"value":0,"ko":"없음","en":"None"},{"value":1,"ko":"진상","en":"Lead"},{"value":2,"ko":"지상","en":"Lag"},{"value":3,"ko":"무부하(피상전력 0)","en":"No load (apparent power 0)"}],"ref":"p.98 Measurement Data"},{"table":"holding-registers","address":10138,"manualAddress":"10139","type":"f32","order":"ABCD","name":{"ko":"상전압 불평형률","en":"Voltage unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.98 Measurement Data"},{"table":"holding-registers","address":10156,"manualAddress":"10157","type":"f32","order":"ABCD","name":{"ko":"전류 불평형률","en":"Current unbalance"},"unit":"%","access":"r","fc":[3],"ref":"p.98 Measurement Data"},{"table":"holding-registers","address":10168,"manualAddress":"10169","type":"f32","order":"ABCD","name":{"ko":"장치 온도","en":"Device temperature"},"unit":"℃","access":"r","fc":[3],"description":{"ko":"온도 단위 설정(Locale)이 화씨면 ℉ 로 나온다.","en":"Reported in ℉ when the Locale temperature unit is Fahrenheit."},"ref":"p.98 Measurement Data"},{"table":"holding-registers","address":10250,"manualAddress":"10251","type":"s32","order":"ABCD","name":{"ko":"수전 유효전력량","en":"Received active energy"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"단위는 전력량 단위 설정을 따른다(기본 kWh, Wh 로 바꿀 수 있음).","en":"Unit follows the energy-unit setting (default kWh, can be Wh)."},"ref":"p.99 Measurement Data"},{"table":"holding-registers","address":10252,"manualAddress":"10253","type":"s32","order":"ABCD","name":{"ko":"송전 유효전력량","en":"Delivered active energy"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"단위는 전력량 단위 설정을 따른다(기본 kWh, Wh 로 바꿀 수 있음).","en":"Unit follows the energy-unit setting (default kWh, can be Wh)."},"ref":"p.99 Measurement Data"},{"table":"holding-registers","address":10256,"manualAddress":"10257","type":"s32","order":"ABCD","name":{"ko":"유효전력량 차(수전 − 송전)","en":"Net active energy (received − delivered)"},"unit":"kWh","access":"r","fc":[3],"description":{"ko":"단위는 전력량 단위 설정을 따른다(기본 kWh, Wh 로 바꿀 수 있음).","en":"Unit follows the energy-unit setting (default kWh, can be Wh)."},"ref":"p.99 Measurement Data"},{"table":"holding-registers","address":10266,"manualAddress":"10267","type":"s32","order":"ABCD","name":{"ko":"양의 무효전력량","en":"Positive reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.99 Measurement Data"},{"table":"holding-registers","address":10268,"manualAddress":"10269","type":"s32","order":"ABCD","name":{"ko":"음의 무효전력량","en":"Negative reactive energy"},"unit":"kVARh","access":"r","fc":[3],"ref":"p.99 Measurement Data"},{"table":"holding-registers","address":10274,"manualAddress":"10275","type":"s32","order":"ABCD","name":{"ko":"피상전력량","en":"Apparent energy"},"unit":"kVAh","access":"r","fc":[3],"ref":"p.99 Measurement Data"},{"table":"holding-registers","address":10496,"manualAddress":"10497","type":"f32","order":"ABCD","name":{"ko":"평균 전류 디맨드","en":"Average demand current"},"unit":"A","access":"r","fc":[3],"ref":"p.100 Measurement Data"},{"table":"holding-registers","address":10504,"manualAddress":"10505","type":"f32","order":"ABCD","name":{"ko":"총 유효전력 디맨드","en":"Total demand active power"},"unit":"kW","access":"r","fc":[3],"ref":"p.100 Measurement Data"},{"table":"holding-registers","address":10590,"manualAddress":"10591","type":"u16","name":{"ko":"전력량 단위","en":"Energy unit"},"access":"r","fc":[3],"values":[{"value":0,"ko":"kWh","en":"kWh"},{"value":1,"ko":"Wh","en":"Wh"}],"description":{"ko":"유효전력량 단위 설정(Locale)을 따른다 — 1 이면 유효전력량이 Wh.","en":"Follows the Locale energy-unit setting; 1 means active energy is in Wh."},"ref":"p.101 Measurement Data"}],"notes":[{"ko":"계측값은 aggregation 버퍼에 있다 — 9901 로 구간(기본 1초)을 고르고, 9902 가 기본(최신)이면 바로 10001~ 을 읽어도 되고 아니면 9911 을 읽어 가져온 뒤 읽는다. 선택·index 는 접속마다 따로 (p.88-93, p.169, p.184-188).","en":"Measurements live in aggregation buffers: select the interval with 9901 (default 1 s); with 9902 at its default (Newest) read 10001- directly, otherwise read 9911 to fetch first. Selection/index are per connection (p.88-93, p.169, p.184-188)."},{"ko":"포트마다 기본 레지스터 맵을 고를 수 있다(65534: 0 Accura 3700, 1 Old Accura 3700) — 이 파일은 0(새 맵) 기준 (p.39).","en":"Each port can use a different default register map (65534: 0 Accura 3700, 1 Old Accura 3700); this file follows map 0 (p.39)."},{"ko":"값은 실제 단위 Float32(V·A·kW…), 계측 영역의 전력량은 Int32 kWh 등 — PT/CT 배율을 따로 곱하지 않는다. 유효전력량 단위는 3024(Locale)로 Wh 로 바꿀 수 있고 10591 로 확인 (p.68, p.99, p.101). 전력량 설정 영역(8101~)은 Int64 라 넣지 않았다.","en":"Values are Float32 in engineering units; energies in the measurement area are Int32 kWh etc., no PT/CT scaling needed. Active-energy unit can be switched to Wh with 3024 (Locale); check 10591 (p.68, p.99, p.101). The energy preset area (8101-) is Int64 and is left out."},{"ko":"디맨드는 10171~10201 과 10491~10521 두 곳에 같은 이름으로 있다 — 여기선 10491~ 쪽을 적었다 (p.98-101).","en":"Demand values appear twice with the same names (10171-10201 and 10491-10521); this file lists the 10491- set (p.98-101)."},{"ko":"원격 설정은 기본 잠금 — 쓰기 전에 2901 에 2300→0→700→1 (p.21, p.182). 직렬 설정은 3701 접근 레지스터로 가져오기/적용 (p.37).","en":"Remote setup is locked by default; unlock with 2300→0→700→1 to 2901 (p.21, p.182). Serial settings are fetched/applied via access register 3701 (p.37)."}],"sources":[{"title":"Accura 3700 Communication Guide","publisher":"Rootech Inc.","edition":{"ko":"Revision 2.40, 2026-04-17 (파일명 Accura_3700_Communication_Guide_Rev2_40_Korean_260417.pdf)","en":"Revision 2.40, 2026-04-17 (file name Accura_3700_Communication_Guide_Rev2_40_Korean_260417.pdf)"},"url":"https://www.rootech.com/bbs/download.php?bo_table=m3_03_2&wr_id=1460&no=0","pages":{"ko":"p.14-17 맵 요약·형식·시스템 정보, p.21, p.37, p.39, p.88-101 계측, p.165-177 프로토콜·RTU/TCP 예, p.179-188 주소·엔디언·수집 절차","en":"pp.14-17 map summary, formats, system info, p.21, p.37, p.39, pp.88-101 measurements, pp.165-177 protocol and RTU/TCP examples, pp.179-188 addressing, endian, collection"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"schneider-electric/atv12","manufacturer":{"ko":"슈나이더 일렉트릭","en":"Schneider Electric"},"model":"ATV12","models":["Altivar 12"],"kind":"inverter","title":{"ko":"슈나이더 일렉트릭 Altivar 12 (ATV12) 인버터 (RJ45 Modbus RTU)","en":"Schneider Electric Altivar 12 (ATV12) drive (RJ45 Modbus RTU)"},"summary":{"ko":"RJ45 포트 Modbus RTU. 논리 주소 = 프레임 주소: 명령 워드 CMD 8501, 상태 워드 ETA 3201, 속도 한계·최대 주파수 3102~3105, 통신 스캐너 12701~12764","en":"RJ45 port Modbus RTU. Logical address = frame address: command word CMD 8501, status word ETA 3201, speed limits and max frequency 3102-3105, communication scanner 12701-12764"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":63,"addressing":"zero","notes":[{"ko":"주소 체계: 매뉴얼 읽기 예(p.13)는 02 03 0C 1E 00 04 27 6C 로 W3102~W3105 를 읽고 02 03 08 00 28 02 58 01 F4 00 00 52 B0 을 받는다. 쓰기 예(p.14)는 02 06 23 29 00 0D 92 70 (W9001). 매뉴얼 번호 = 프레임 주소(0 기준). CRC 도 계산값과 맞다.","en":"Addressing: the read example (p.13) sends 02 03 0C 1E 00 04 27 6C to read W3102-W3105 and gets 02 03 08 00 28 02 58 01 F4 00 00 52 B0; the write example (p.14) is 02 06 23 29 00 0D 92 70 (W9001). Manual number = frame address (0-based). CRCs match calculation."},{"ko":"출하값: Add = OFF(브로드캐스트만 받음 — 응답하려면 1~247 로), tbr 19.2 kbps, tFd 8E1, ttO 10.0 s (p.9). 8O1·8E1·8N1·8N2 와 4.8~38.4 kbps 를 고를 수 있다.","en":"Factory settings: Add = OFF (broadcast only; set 1-247 to get replies), tbr 19.2 kbps, tFd 8E1, ttO 10.0 s (p.9). 8O1/8E1/8N1/8N2 and 4.8-38.4 kbps selectable."},{"ko":"함수 코드 03(최대 63워드)·06·16(최대 61워드)·23(읽기 4·쓰기 4워드)·43/14(장치 식별) (p.12).","en":"Function codes 03 (up to 63 words), 06, 16 (up to 61 words), 23 (4 read + 4 write words), 43/14 (device identification) (p.12)."}]},"registers":[{"table":"holding-registers","address":3102,"manualAddress":"3102","type":"u16","name":{"ko":"SFr 스위칭 주파수","en":"SFr switching frequency"},"unit":"kHz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 4 kHz = 0028h","en":"Manual read example: 4 kHz = 0028h"},"ref":"p.13","source":0},{"table":"holding-registers","address":3103,"manualAddress":"3103","type":"u16","name":{"ko":"tFr 최대 출력 주파수","en":"tFr maximum output frequency"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 60 Hz = 0258h","en":"Manual read example: 60 Hz = 0258h"},"ref":"p.13","source":0},{"table":"holding-registers","address":3104,"manualAddress":"3104","type":"u16","name":{"ko":"HSP 고속","en":"HSP high speed"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 50 Hz = 01F4h","en":"Manual read example: 50 Hz = 01F4h"},"ref":"p.13","source":0},{"table":"holding-registers","address":3105,"manualAddress":"3105","type":"u16","name":{"ko":"LSP 저속","en":"LSP low speed"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 0 Hz = 0000h","en":"Manual read example: 0 Hz = 0000h"},"ref":"p.13","source":0},{"table":"holding-registers","address":3201,"manualAddress":"3201","type":"u16","name":{"ko":"ETA 상태 워드","en":"ETA status word"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 준비(Ready to switch on)","en":"Ready to switch on"},{"bit":1,"ko":"스위치 온(Switched on)","en":"Switched on"},{"bit":2,"ko":"운전 가능(Operation enabled)","en":"Operation enabled"},{"bit":3,"ko":"고장 검출","en":"Fault detection"},{"bit":4,"ko":"전압 인가(늘 1)","en":"Voltage enabled (always 1)"},{"bit":5,"ko":"급정지(0 일 때 동작)","en":"Quick stop (active at 0)"},{"bit":6,"ko":"스위치 온 금지(Switch on disabled)","en":"Switch on disabled"},{"bit":9,"ko":"로컬 모드(0 일 때 동작)","en":"Local mode (active at 0)"},{"bit":10,"ko":"지령 도달(정상 상태)","en":"Reference reached (steady state)"},{"bit":11,"ko":"지령 범위 넘음(< LSP 또는 > HSP)","en":"Reference exceeded (< LSP or > HSP)"},{"bit":14,"ko":"STOP 키로 정지","en":"Stop via STOP key"},{"bit":15,"ko":"회전 방향(0 = 정회전 또는 정지)","en":"Rotation direction (0 = forward or stopped)"}],"description":{"ko":"상태는 하위 7비트(마스크 006Fh)로 본다: 0050h 스위치 온 금지, 0031h 운전 준비, 0033h 스위치 온, 0037h 운전 가능, 0017h 급정지, 0018h·0038h 고장","en":"Check the state with mask 006Fh: 0050h switch on disabled, 0031h ready to switch on, 0033h switched on, 0037h operation enabled, 0017h quick stop active, 0018h/0038h fault"},"ref":"p.20","source":0},{"table":"holding-registers","address":6001,"manualAddress":"6001","type":"u16","name":{"ko":"Add Modbus 국번","en":"Add Modbus address"},"access":"r","fc":[3],"range":{"min":0,"max":247},"description":{"ko":"0 = OFF(브로드캐스트만, 출하값), 1~247","en":"0 = OFF (broadcast only, factory setting), 1-247"},"ref":"p.9","source":0},{"table":"holding-registers","address":8501,"manualAddress":"8501","type":"u16","name":{"ko":"CMD 명령 워드","en":"CMD command word"},"access":"rw","fc":[3,6,16],"values":[{"value":6,"ko":"Shutdown → 운전 준비","en":"Shutdown → ready to switch on"},{"value":7,"ko":"Switch on → 스위치 온","en":"Switch on → switched on"},{"value":15,"ko":"Enable operation → 운전 가능","en":"Enable operation → operation enabled"},{"value":0,"ko":"Disable voltage","en":"Disable voltage"},{"value":2,"ko":"Quick stop","en":"Quick stop"},{"value":128,"ko":"고장 리셋","en":"Fault reset"}],"bits":[{"bit":0,"ko":"스위치 온","en":"Switch on"},{"bit":1,"ko":"스위치 온 금지(0 일 때 동작)","en":"Switch on disabled (active at 0)"},{"bit":2,"ko":"급정지(0 일 때 동작)","en":"Quick stop (active at 0)"},{"bit":3,"ko":"운전 가능","en":"Enable operation"},{"bit":4,"ko":"0 = 운전 가능 상태에서 프리런","en":"0 = freewheel while staying in operation enabled"},{"bit":7,"ko":"고장 리셋(0→1 상승 에지)","en":"Fault reset (0→1 rising edge)"},{"bit":8,"ko":"0 = RUN, 1 = STOP 요청","en":"0 = run, 1 = stop requested"},{"bit":11,"ko":"회전 방향(0 정회전 / 1 역회전)","en":"Rotation direction (0 forward / 1 reverse)"}],"description":{"ko":"IEC 61800-7 상태 기계. 운전은 0006h → 0007h → 000Fh 순서로 쓴다","en":"IEC 61800-7 state machine. To run, write 0006h → 0007h → 000Fh"},"ref":"p.19","source":0},{"table":"holding-registers","address":12701,"manualAddress":"12701","type":"u16","name":{"ko":"nMA1 입력 1번째 말의 원본 주소","en":"nMA1 Source address of the 1st input word"},"access":"r","fc":[3],"description":{"ko":"출하값 3201(ETA)","en":"Factory setting 3201 (ETA)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12702,"manualAddress":"12702","type":"u16","name":{"ko":"nMA2 입력 2번째 말의 원본 주소","en":"nMA2 Source address of the 2nd input word"},"access":"r","fc":[3],"description":{"ko":"출하값 8604","en":"Factory setting 8604"},"ref":"p.10","source":0},{"table":"holding-registers","address":12703,"manualAddress":"12703","type":"u16","name":{"ko":"nMA3 입력 3번째 말의 원본 주소","en":"nMA3 Source address of the 3rd input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(사용 안 함)","en":"Factory setting 0 (not used)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12704,"manualAddress":"12704","type":"u16","name":{"ko":"nMA4 입력 4번째 말의 원본 주소","en":"nMA4 Source address of the 4th input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(사용 안 함)","en":"Factory setting 0 (not used)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12721,"manualAddress":"12721","type":"u16","name":{"ko":"nCA1 출력 1번째 말의 대상 주소","en":"nCA1 Destination address of the 1st output word"},"access":"r","fc":[3],"description":{"ko":"출하값 8501(CMD)","en":"Factory setting 8501 (CMD)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12722,"manualAddress":"12722","type":"u16","name":{"ko":"nCA2 출력 2번째 말의 대상 주소","en":"nCA2 Destination address of the 2nd output word"},"access":"r","fc":[3],"description":{"ko":"출하값 8602","en":"Factory setting 8602"},"ref":"p.10","source":0},{"table":"holding-registers","address":12723,"manualAddress":"12723","type":"u16","name":{"ko":"nCA3 출력 3번째 말의 대상 주소","en":"nCA3 Destination address of the 3rd output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(사용 안 함)","en":"Factory setting 0 (not used)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12724,"manualAddress":"12724","type":"u16","name":{"ko":"nCA4 출력 4번째 말의 대상 주소","en":"nCA4 Destination address of the 4th output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(사용 안 함)","en":"Factory setting 0 (not used)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12741,"manualAddress":"12741","type":"u16","name":{"ko":"nM1 입력 1번째 말 값","en":"nM1 value of input word 1"},"access":"r","fc":[3],"description":{"ko":"nMA1 이 가리키는 값(출하 상태 nM1 = ETA)","en":"Value at the address in nMA1 (factory: nM1 = ETA)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12742,"manualAddress":"12742","type":"u16","name":{"ko":"nM2 입력 2번째 말 값","en":"nM2 value of input word 2"},"access":"r","fc":[3],"description":{"ko":"nMA2 이 가리키는 값(출하 상태 nM1 = ETA)","en":"Value at the address in nMA2 (factory: nM1 = ETA)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12743,"manualAddress":"12743","type":"u16","name":{"ko":"nM3 입력 3번째 말 값","en":"nM3 value of input word 3"},"access":"r","fc":[3],"description":{"ko":"nMA3 이 가리키는 값(출하 상태 nM1 = ETA)","en":"Value at the address in nMA3 (factory: nM1 = ETA)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12744,"manualAddress":"12744","type":"u16","name":{"ko":"nM4 입력 4번째 말 값","en":"nM4 value of input word 4"},"access":"r","fc":[3],"description":{"ko":"nMA4 이 가리키는 값(출하 상태 nM1 = ETA)","en":"Value at the address in nMA4 (factory: nM1 = ETA)"},"ref":"p.10","source":0},{"table":"holding-registers","address":12761,"manualAddress":"12761","type":"u16","name":{"ko":"nC1 출력 1번째 말 값","en":"nC1 value of output word 1"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA1 이 가리키는 곳에 쓰인다(출하 상태 nC1 = CMD). 매뉴얼 응용 예는 12761 부터 4개를 FC16 으로 쓴다","en":"Written to the address in nCA1 (factory: nC1 = CMD). The manual application example writes 4 words from 12761 with FC16"},"ref":"p.10, p.23","source":0},{"table":"holding-registers","address":12762,"manualAddress":"12762","type":"u16","name":{"ko":"nC2 출력 2번째 말 값","en":"nC2 value of output word 2"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA2 이 가리키는 곳에 쓰인다(출하 상태 nC1 = CMD). 매뉴얼 응용 예는 12761 부터 4개를 FC16 으로 쓴다","en":"Written to the address in nCA2 (factory: nC1 = CMD). The manual application example writes 4 words from 12761 with FC16"},"ref":"p.10, p.23","source":0},{"table":"holding-registers","address":12763,"manualAddress":"12763","type":"u16","name":{"ko":"nC3 출력 3번째 말 값","en":"nC3 value of output word 3"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA3 이 가리키는 곳에 쓰인다(출하 상태 nC1 = CMD). 매뉴얼 응용 예는 12761 부터 4개를 FC16 으로 쓴다","en":"Written to the address in nCA3 (factory: nC1 = CMD). The manual application example writes 4 words from 12761 with FC16"},"ref":"p.10, p.23","source":0},{"table":"holding-registers","address":12764,"manualAddress":"12764","type":"u16","name":{"ko":"nC4 출력 4번째 말 값","en":"nC4 value of output word 4"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA4 이 가리키는 곳에 쓰인다(출하 상태 nC1 = CMD). 매뉴얼 응용 예는 12761 부터 4개를 FC16 으로 쓴다","en":"Written to the address in nCA4 (factory: nC1 = CMD). The manual application example writes 4 words from 12761 with FC16"},"ref":"p.10, p.23","source":0}],"notes":[{"ko":"이 매뉴얼에 단위·배율이 나온 레지스터만 넣었다. 매뉴얼은 FC03 으로 모든 워드를 읽을 수 있다고만 하고 파라미터별 쓰기 가능 여부는 적지 않아, 쓰기가 예로 확인된 CMD(8501)·nC1~4 말고는 읽기(r)로 적었다(설정 메뉴에서 바꾸는 값).  나머지 파라미터의 주소·단위는 슈나이더의 파라미터 엑셀 파일(BBV51917)에 있는데 공식 경로로 받지 못해 넣지 않았다(가속 시간 W9001 도 예시 값과 단위가 맞는지 확인 못 함).","en":"Only registers whose unit/scale is given in this manual are included. The manual only says FC03 can read all words and does not state per-parameter write access, so everything except CMD (8501) and nC1-4 (writes shown) is listed as read (r); these are set from the menus.  Other parameter addresses and units are in Schneider's parameter Excel file (BBV51917), which could not be downloaded from an official link, so they are left out (W9001 acceleration time also, as its example value could not be matched to a unit)."}],"sources":[{"title":"Altivar 12 Modbus Communication Manual","publisher":"Schneider Electric","edition":{"ko":"BBV28590 06/2012","en":"BBV28590 06/2012"},"url":"https://download.se.com/files?p_Doc_Ref=BBV28590&p_enDocType=User+guide&p_File_Name=ATV12_Modbus_EN_BBV28590_02.pdf","pages":{"ko":"통신 설정 p.9, 통신 스캐너 p.10-11, Modbus 함수·예 p.12-16, 상태 기계 CMD·ETA p.17-20, 응용 예 p.23","en":"Communication settings p.9, scanner pp.10-11, Modbus functions and examples pp.12-16, state machine CMD/ETA pp.17-20, application example p.23"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"schneider-electric/atv312","manufacturer":{"ko":"슈나이더 일렉트릭","en":"Schneider Electric"},"model":"ATV312","models":["Altivar 312"],"kind":"inverter","title":{"ko":"슈나이더 일렉트릭 Altivar 312 (ATV312) 인버터 (RJ45 Modbus RTU)","en":"Schneider Electric Altivar 312 (ATV312) drive (RJ45 Modbus RTU)"},"summary":{"ko":"RJ45 포트 Modbus RTU. 논리 주소(10진) = 프레임 주소: 명령 CMD 8501·주파수 기준 LFr 8502, 상태 ETA 3201·출력 주파수 rFr 3202, 고장 7121~, 통신 설정 6001~6005","en":"RJ45 port Modbus RTU. Logical address (decimal) = frame address: command CMD 8501, frequency reference LFr 8502, status ETA 3201, output frequency rFr 3202, faults from 7121, communication settings 6001-6005"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200],"dataBits":8,"parity":"even","stopBits":1,"unit":1,"unitRange":[1,247],"maxRegisters":29,"addressing":"zero","notes":[{"ko":"주소 체계: Modbus 매뉴얼 BBV52816 의 읽기 예(p.12)는 02 03 0C 1E 00 04 27 6C 로 W3102~W3105(16#0C1E~)를 읽고 02 03 08 00 28 02 58 01 F4 00 00 52 B0 을 받으며(SFr 4 kHz·tFr 60 Hz·HSP 50 Hz·LSP 0 — 변수 매뉴얼의 0.1 kHz·0.1 Hz 단위와 맞다), 쓰기 예(p.12)는 02 06 23 29 00 0D 92 70 (W9001 = 16#2329). 매뉴얼 번호(10진) = 프레임 주소. 이 세 프레임과 장치 식별 요청(02 2B 0E 01 00 34 77)의 CRC 는 계산값과 같다. FC16 예(p.14)의 CRC 는 51 7F·8F ED 로 적혀 있으나 계산값은 73 A4·9B B7 — 주소와는 무관.","en":"Addressing: the read example in Modbus manual BBV52816 (p.12) sends 02 03 0C 1E 00 04 27 6C to read W3102-W3105 (16#0C1E-) and gets 02 03 08 00 28 02 58 01 F4 00 00 52 B0 (SFr 4 kHz, tFr 60 Hz, HSP 50 Hz, LSP 0, matching the 0.1 kHz / 0.1 Hz units in the variables manual); the write example (p.12) is 02 06 23 29 00 0D 92 70 (W9001 = 16#2329). Manual number (decimal) = frame address. CRCs of these three frames and of the identification request (02 2B 0E 01 00 34 77) match calculation. The FC16 example (p.14) prints CRCs 51 7F and 8F ED but they compute to 73 A4 and 9B B7; this does not affect addressing."},{"ko":"출하값: Add 1(1~247), tbr 19.2 kbps(4.8·9.6·19.2), tFO 8E1(8O1·8E1·8N1·8N2), ttO 10 s (BBV52816 p.9·p.11). 원격 표시기는 19.2 kbps·8E1 에서만 쓴다.","en":"Factory settings: Add 1 (1-247), tbr 19.2 kbps (4.8/9.6/19.2), tFO 8E1 (8O1/8E1/8N1/8N2), ttO 10 s (BBV52816 p.9, p.11). The remote display terminal needs 19.2 kbps and 8E1."},{"ko":"함수 코드 03(최대 29워드)·06·16(최대 27워드)·43(장치 식별) (BBV52816 p.12).","en":"Function codes 03 (up to 29 words), 06, 16 (up to 27 words) and 43 (identification) (BBV52816 p.12)."}]},"notes":[{"ko":"레지스터 주소·단위·읽기/쓰기는 통신 변수 매뉴얼 BBV51701(쪽 번호는 이 매뉴얼). R/WS(정지 중에만 쓰기)는 rw 로 적고 설명에 남겼다.","en":"Register addresses, units and read/write come from the communication variables manual BBV51701 (page numbers refer to it). R/WS (write only while stopped) is listed as rw and noted in the description."},{"ko":"가속 ACC(9001)·감속 dEC(9002)는 넣지 않았다 — 변수 매뉴얼(p.39)은 단위 0.1 s(출하값 30 = 3 s, Inr 에 따라 바뀜)인데 Modbus 매뉴얼의 예(p.12·p.14)는 W9001 = 16#000D 를 «ACC = 13 s», 20·30 을 «20 s·30 s» 로 적어 배율이 어긋난다.","en":"Acceleration ACC (9001) and deceleration dEC (9002) are not included: the variables manual (p.39) gives a 0.1 s unit (factory 30 = 3 s, depending on Inr), while the Modbus manual examples (p.12, p.14) call W9001 = 16#000D «ACC = 13 s» and 20/30 «20 s/30 s», so the scaling disagrees."},{"ko":"가상 아날로그 입력 AIV1 은 넣지 않았다 — 변수 매뉴얼에 단위 % 만 있고 배율(1 % 당 값)이 적혀 있지 않다.","en":"The virtual analog input AIV1 is not included: the variables manual gives only the unit % without a scale (value per 1 %)."},{"ko":"CMD 로 운전하려면 접근 수준 LAC = L3 에서 제어 채널을 Modbus 로 정하고 상태 기계(0006h → 0007h → 000Fh)를 따른다. L1·L2 에서는 전원 투입 때 바로 «운전 가능» 이 된다 (p.11).","en":"To run by CMD set access level LAC = L3, select Modbus as the control channel and follow the state machine (0006h -> 0007h -> 000Fh). In L1/L2 the drive goes to «Operation enabled» at power up (p.11)."}],"registers":[{"table":"holding-registers","address":3102,"manualAddress":"3102","type":"u16","name":{"ko":"SFr 스위칭 주파수","en":"SFr switching frequency"},"unit":"kHz","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":2,"max":16},"description":{"ko":"출하값 40(4 kHz)","en":"Factory setting 40 (4 kHz)"},"ref":"p.31","source":1},{"table":"holding-registers","address":3103,"manualAddress":"3103","type":"u16","name":{"ko":"tFr 최대 출력 주파수","en":"tFr maximum output frequency"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":10,"max":500},"description":{"ko":"출하값 600(bFr = 50) / 720(bFr = 60). 정지 중에만 쓸 수 있다(R/WS)","en":"Factory setting 600 (bFr = 50) / 720 (bFr = 60). Writable only while stopped (R/WS)"},"ref":"p.31","source":1},{"table":"holding-registers","address":3104,"manualAddress":"3104","type":"u16","name":{"ko":"HSP 고속","en":"HSP high speed"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"최대 기준일 때 모터 주파수. 출하값 500(bFr = 50) / 600(bFr = 60), 범위 LSP~tFr","en":"Motor frequency at max. reference. Factory 500 (bFr = 50) / 600 (bFr = 60), range LSP to tFr"},"ref":"p.27","source":1},{"table":"holding-registers","address":3105,"manualAddress":"3105","type":"u16","name":{"ko":"LSP 저속","en":"LSP low speed"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"최소 기준일 때 모터 주파수. 출하값 0, 범위 0~HSP","en":"Motor frequency at min. reference. Factory 0, range 0 to HSP"},"ref":"p.27","source":1},{"table":"holding-registers","address":3201,"manualAddress":"3201","type":"u16","name":{"ko":"ETA 상태 워드","en":"ETA status word"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"스위치 온 준비","en":"Ready to switch on"},{"bit":1,"ko":"스위치 온","en":"Switched on"},{"bit":2,"ko":"운전 가능","en":"Operation enabled"},{"bit":3,"ko":"고장 검출(FAI)","en":"Malfunction, detected fault (FAI)"},{"bit":4,"ko":"전압 차단(늘 0)","en":"Voltage disabled (always 0)"},{"bit":5,"ko":"퀵 스톱(0 에서 동작)","en":"Quick stop (active at 0)"},{"bit":6,"ko":"스위치 온 불가","en":"Switch on disabled"},{"bit":7,"ko":"알람 있음","en":"Alarm present"},{"bit":9,"ko":"1 = 강제 로컬 아님(0 = FLO 중)","en":"1 = no forced local mode (0 = FLO in progress)"},{"bit":10,"ko":"기준 도달","en":"Reference reached"},{"bit":11,"ko":"LFRD 기준 초과(< LSP 또는 > HSP)","en":"LFRD reference exceeded (< LSP or > HSP)"},{"bit":14,"ko":"STOP 키로 정지","en":"Stop imposed by STOP key"},{"bit":15,"ko":"역회전(출력 주파수)","en":"Reverse rotation (output frequency)"}],"description":{"ko":"값 예: 0627h 정회전·속도 도달, 8627h 역회전·속도 도달, 0227h 정회전 가감속 중 (p.10)","en":"Examples: 0627h forward, speed reached; 8627h reverse, speed reached; 0227h forward, ACC or DEC (p.10)"},"ref":"p.21","source":1},{"table":"holding-registers","address":3202,"manualAddress":"3202","type":"s16","name":{"ko":"rFr 출력 주파수","en":"rFr output frequency"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"CMI 비트 9 = 0(출하) 일 때 0.1 Hz. 비트 9 = 1 이면 32767 = 600 Hz","en":"0.1 Hz when CMI bit 9 = 0 (factory). With bit 9 = 1, 32767 = 600 Hz"},"ref":"p.21","source":1},{"table":"holding-registers","address":3203,"manualAddress":"3203","type":"u16","name":{"ko":"FrH 램프 전 주파수 기준","en":"FrH frequency reference before ramp"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"ref":"p.21","source":1},{"table":"holding-registers","address":3204,"manualAddress":"3204","type":"u16","name":{"ko":"LCr 모터 전류","en":"LCr motor current"},"unit":"A","scale":0.1,"access":"r","fc":[3],"ref":"p.21","source":1},{"table":"holding-registers","address":3205,"manualAddress":"3205","type":"u16","name":{"ko":"Otr 모터 토크","en":"Otr motor torque"},"unit":"%","access":"r","fc":[3],"description":{"ko":"100% = 모터 정격 토크","en":"100% = nominal motor torque"},"ref":"p.21","source":1},{"table":"holding-registers","address":3206,"manualAddress":"3206","type":"u16","name":{"ko":"ETI 확장 상태 워드","en":"ETI extended status word"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"파라미터 쓰기 불가(EEPROM 저장 중)","en":"Write parameters not authorized (saving to EEPROM)"},{"bit":1,"ko":"파라미터 정합성 검사","en":"Parameter consistency check"},{"bit":2,"ko":"고장 리셋 가능","en":"Fault state reset authorized"},{"bit":4,"ko":"모터 운전 중","en":"Motor running"},{"bit":5,"ko":"직류 제동 중","en":"DC injection"},{"bit":6,"ko":"과도 상태","en":"Drive in transient state"},{"bit":7,"ko":"모터 열 과부하 알람","en":"Motor thermal overload alarm"},{"bit":8,"ko":"과도 제동 알람","en":"Alarm if excessive braking"},{"bit":9,"ko":"가속 중","en":"Drive accelerating"},{"bit":10,"ko":"감속 중","en":"Drive decelerating"},{"bit":11,"ko":"전류 제한 알람","en":"Current limit alarm"},{"bit":12,"ko":"고속 정지 중","en":"Fast stop in progress"},{"bit":13,"ko":"제어 채널 비트 a(14·13: 00 단자·키패드, 01 원격 표시기, 10 Modbus, 11 CANopen)","en":"Control channel bit a (14/13: 00 terminals/keypad, 01 remote display, 10 Modbus, 11 CANopen)"},{"bit":14,"ko":"제어 채널 비트 b","en":"Control channel bit b"},{"bit":15,"ko":"역회전 요청(기준)","en":"Reverse rotation requested (reference)"}],"ref":"p.22","source":1},{"table":"holding-registers","address":3207,"manualAddress":"3207","type":"u16","name":{"ko":"ULn 전원 전압","en":"ULn line voltage"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"직류 버스로 구한 전원 전압","en":"Line voltage via the DC bus"},"ref":"p.21","source":1},{"table":"holding-registers","address":3209,"manualAddress":"3209","type":"u16","name":{"ko":"tHd 드라이브 열 상태","en":"tHd drive thermal state"},"unit":"%","access":"r","fc":[3],"description":{"ko":"100% = 정격, 118% = OHF 문턱","en":"100% = nominal, 118% = OHF threshold"},"ref":"p.21","source":1},{"table":"holding-registers","address":3210,"manualAddress":"3210","type":"u16","name":{"ko":"TDM 드라이브 최대 열 상태","en":"TDM max. drive thermal state"},"unit":"%","access":"r","fc":[3],"description":{"ko":"전원을 끄면 0","en":"Reset to zero at power down"},"ref":"p.21","source":1},{"table":"holding-registers","address":3211,"manualAddress":"3211","type":"u16","name":{"ko":"OPr 모터 출력","en":"OPr motor power"},"unit":"%","access":"r","fc":[3],"description":{"ko":"100% = 모터 정격 출력","en":"100% = nominal motor power"},"ref":"p.21","source":1},{"table":"holding-registers","address":3231,"manualAddress":"3231","type":"u16","name":{"ko":"rtH 운전 시간","en":"rtH operating time"},"unit":"h","access":"r","fc":[3],"description":{"ko":"모터에 전원이 들어간 누적 시간. rPr 로 0","en":"Total time the motor has been powered up. Reset by rPr"},"ref":"p.21","source":1},{"table":"holding-registers","address":3250,"manualAddress":"3250","type":"u16","name":{"ko":"LRS1 확장 상태 워드 1","en":"LRS1 extended status word 1"},"access":"r","fc":[3],"bits":[{"bit":1,"ko":"드라이브 고장","en":"Drive detected fault"},{"bit":2,"ko":"모터 운전 중","en":"Motor running"},{"bit":4,"ko":"주파수 문턱(Ftd) 도달","en":"Frequency threshold (Ftd) reached"},{"bit":5,"ko":"고속 도달","en":"High speed reached"},{"bit":6,"ko":"전류 문턱(Ctd) 도달","en":"Current threshold (Ctd) reached"},{"bit":7,"ko":"속도 기준 도달","en":"Speed reference reached"},{"bit":8,"ko":"모터 열 과부하 알람","en":"Motor thermal overload alarm"},{"bit":9,"ko":"브레이크 제어 중(해제)","en":"Brake control in progress (released)"},{"bit":12,"ko":"4~20 mA 손실","en":"Loss of 4-20 mA"},{"bit":14,"ko":"드라이브 열 과부하 알람","en":"Drive thermal overload alarm"}],"ref":"p.22","source":1},{"table":"holding-registers","address":3252,"manualAddress":"3252","type":"u16","name":{"ko":"LRS3 확장 상태 워드 3","en":"LRS3 extended status word 3"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"기준이 Fr2","en":"Reference given by Fr2"},{"bit":1,"ko":"명령이 Fr2·Cd2","en":"Command given by Fr2 or Cd2"},{"bit":2,"ko":"ACC2·DEC2 사용","en":"ACC2 and DEC2 used"},{"bit":3,"ko":"CL2 로 전류 제한","en":"CL2 used for current limiting"},{"bit":11,"ko":"모터 1 사용","en":"Motor 1 is used"},{"bit":12,"ko":"모터 2 사용","en":"Motor 2 is used"}],"ref":"p.23","source":1},{"table":"holding-registers","address":5240,"manualAddress":"5240","type":"u16","name":{"ko":"IOLR 논리 입출력 값","en":"IOLR value of logic I/O"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"LI1 입력","en":"Logic input LI1"},{"bit":1,"ko":"LI2 입력","en":"Logic input LI2"},{"bit":2,"ko":"LI3 입력","en":"Logic input LI3"},{"bit":3,"ko":"LI4 입력","en":"Logic input LI4"},{"bit":4,"ko":"LI5 입력","en":"Logic input LI5"},{"bit":5,"ko":"LI6 입력","en":"Logic input LI6"},{"bit":7,"ko":"키패드 있음","en":"Keypad present"},{"bit":8,"ko":"R1 릴레이 출력","en":"R1 relay output"},{"bit":9,"ko":"R2 릴레이 출력","en":"R2 relay output"},{"bit":10,"ko":"LO 논리 출력","en":"LO logic output"},{"bit":14,"ko":"0 = AOC/AOV 논리 출력, 1 = 아날로그 출력","en":"0 = AOC/AOV logic output, 1 = analog output"}],"description":{"ko":"비트 8~10 만 쓸 수 있고, 그 출력이 기능에 배정되지 않았을 때만","en":"Only bits 8-10 are writable, and only when that output is not assigned"},"ref":"p.20, p.23","source":1},{"table":"holding-registers","address":5242,"manualAddress":"5242","type":"u16","name":{"ko":"AI1C 아날로그 입력 AI1","en":"AI1C analog input AI1"},"unit":"mV","access":"r","fc":[3],"range":{"min":0,"max":10000},"ref":"p.23","source":1},{"table":"holding-registers","address":5243,"manualAddress":"5243","type":"s16","name":{"ko":"AI2C 아날로그 입력 AI2","en":"AI2C analog input AI2"},"unit":"mV","access":"r","fc":[3],"range":{"min":-10000,"max":10000},"ref":"p.23","source":1},{"table":"holding-registers","address":5244,"manualAddress":"5244","type":"u16","name":{"ko":"AI3C 아날로그 입력 AI3","en":"AI3C analog input AI3"},"unit":"µA","access":"r","fc":[3],"range":{"min":0,"max":20000},"ref":"p.23","source":1},{"table":"holding-registers","address":5261,"manualAddress":"5261","type":"u16","name":{"ko":"AO1R 아날로그 출력 값","en":"AO1R analog output value"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":10000},"description":{"ko":"10000 = 10 V(AO1t = 10U) 또는 20 mA(OA·4A). dO 가 배정되지 않았을 때만 쓸 수 있다","en":"10000 = 10 V (AO1t = 10U) or 20 mA (OA/4A). Writable only when dO is not assigned"},"ref":"p.20, p.23","source":1},{"table":"holding-registers","address":6001,"manualAddress":"6001","type":"u16","name":{"ko":"Add Modbus 국번","en":"Add Modbus drive address"},"access":"rw","fc":[3,6,16],"range":{"min":1,"max":247},"description":{"ko":"출하값 1. 정지 중에만 쓸 수 있다(R/WS)","en":"Factory setting 1. Writable only while stopped (R/WS)"},"ref":"p.55","source":1},{"table":"holding-registers","address":6003,"manualAddress":"6003","type":"u16","name":{"ko":"tbr Modbus 통신 속도","en":"tbr Modbus transmission speed"},"access":"rw","fc":[3,6,16],"values":[{"value":24,"ko":"4800 bps","en":"4800 bps"},{"value":28,"ko":"9600 bps","en":"9600 bps"},{"value":32,"ko":"19200 bps","en":"19200 bps"}],"description":{"ko":"출하값 32. 원격 표시기는 19200 bps 에서만. 정지 중에만 쓸 수 있다(R/WS)","en":"Factory setting 32. The remote display terminal works only at 19200 bps. Writable only while stopped (R/WS)"},"ref":"p.55","source":1},{"table":"holding-registers","address":6004,"manualAddress":"6004","type":"u16","name":{"ko":"tFO Modbus 통신 형식","en":"tFO Modbus communication format"},"access":"rw","fc":[3,6,16],"values":[{"value":2,"ko":"8O1","en":"8O1"},{"value":3,"ko":"8E1","en":"8E1"},{"value":4,"ko":"8N1","en":"8N1"},{"value":5,"ko":"8N2","en":"8N2"}],"description":{"ko":"출하값 3(8E1). 원격 표시기는 8E1 에서만. 정지 중에만 쓸 수 있다(R/WS)","en":"Factory setting 3 (8E1). The remote display terminal works only with 8E1. Writable only while stopped (R/WS)"},"ref":"p.55","source":1},{"table":"holding-registers","address":6005,"manualAddress":"6005","type":"u16","name":{"ko":"ttO Modbus 타임아웃","en":"ttO Modbus time-out"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":10},"description":{"ko":"출하값 100(10 s). 정지 중에만 쓸 수 있다(R/WS)","en":"Factory setting 100 (10 s). Writable only while stopped (R/WS)"},"ref":"p.55","source":1},{"table":"holding-registers","address":7121,"manualAddress":"7121","type":"u16","name":{"ko":"LFt 마지막 고장","en":"LFt last detected fault"},"access":"r","fc":[3],"values":[{"value":0,"ko":"nOF 고장 기록 없음","en":"nOF: no fault code saved"},{"value":3,"ko":"CFF 설정 오류","en":"CFF: incorrect configuration"},{"value":4,"ko":"CFI 잘못된 설정","en":"CFI: invalid configuration"},{"value":5,"ko":"SLF Modbus 통신 끊김","en":"SLF: Modbus communication interruption"},{"value":6,"ko":"ILF 내부 통신 끊김","en":"ILF: internal communication interruption"},{"value":7,"ko":"CnF 통신 옵션 카드","en":"CnF: communication option card"},{"value":8,"ko":"EPF 외부 고장","en":"EPF: external fault"},{"value":9,"ko":"OCF 과전류","en":"OCF: overcurrent"},{"value":10,"ko":"CrF 콘덴서 예비 충전","en":"CrF: capacitor pre-charge"},{"value":13,"ko":"LFF 4~20 mA 손실","en":"LFF: 4-20 mA loss"},{"value":16,"ko":"OHF 드라이브 과열","en":"OHF: drive overheating"},{"value":17,"ko":"OLF 모터 과부하","en":"OLF: motor overload"},{"value":18,"ko":"ObF 직류 버스 과전압","en":"ObF: DC bus overvoltage"},{"value":19,"ko":"OSF 전원 과전압","en":"OSF: line supply overvoltage"},{"value":20,"ko":"OPF 모터 결상","en":"OPF: motor phase loss"},{"value":21,"ko":"PHF 전원 결상","en":"PHF: line phase loss"},{"value":22,"ko":"USF 전원 저전압","en":"USF: line supply undervoltage"},{"value":23,"ko":"SCF 모터 단락(상간)","en":"SCF: motor short-circuit (phase to phase)"},{"value":24,"ko":"SOF 모터 과속","en":"SOF: motor overspeed"},{"value":25,"ko":"tnF 오토 튜닝 실패","en":"tnF: auto-tuning unsuccessful"},{"value":26,"ko":"IF1 알 수 없는 정격","en":"IF1: unknown rating"},{"value":27,"ko":"IF2 MMI 카드","en":"IF2: MMI card"},{"value":28,"ko":"IF3 MMI 통신","en":"IF3: MMI communication"},{"value":29,"ko":"IF4 산업용 EEPROM","en":"IF4: industrial EEPROM"},{"value":30,"ko":"EEF EEPROM 메모리","en":"EEF: EEPROM memory"},{"value":31,"ko":"SCF 임박 단락","en":"SCF: impeding short-circuit"},{"value":32,"ko":"SCF 모터 지락","en":"SCF: motor short-circuit (to ground)"},{"value":33,"ko":"OPF 모터 3상 결상","en":"OPF: motor phase loss, 3 phases"},{"value":34,"ko":"COF 통신 끊김(CANopen)","en":"COF: communication interruption (CANopen)"},{"value":35,"ko":"bLF 브레이크 제어","en":"bLF: brake control"},{"value":36,"ko":"OCF 파워 모듈(ATV312·D15·)","en":"OCF: power module (ATV312·D15·)"},{"value":55,"ko":"SCF 전원 투입 시 파워 모듈·모터 단락","en":"SCF: power module or motor short-circuit at power up"}],"description":{"ko":"원인이 없어지거나 전원을 다시 넣어도 남는다","en":"Kept after the cause disappears and after power cycling"},"ref":"p.24","source":1},{"table":"holding-registers","address":7201,"manualAddress":"7201","type":"u16","name":{"ko":"DP1 지난 고장 1","en":"DP1 past detected fault 1"},"access":"r","fc":[3],"values":[{"value":0,"ko":"nOF 고장 기록 없음","en":"nOF: no fault code saved"},{"value":3,"ko":"CFF 설정 오류","en":"CFF: incorrect configuration"},{"value":4,"ko":"CFI 잘못된 설정","en":"CFI: invalid configuration"},{"value":5,"ko":"SLF Modbus 통신 끊김","en":"SLF: Modbus communication interruption"},{"value":6,"ko":"ILF 내부 통신 끊김","en":"ILF: internal communication interruption"},{"value":7,"ko":"CnF 통신 옵션 카드","en":"CnF: communication option card"},{"value":8,"ko":"EPF 외부 고장","en":"EPF: external fault"},{"value":9,"ko":"OCF 과전류","en":"OCF: overcurrent"},{"value":10,"ko":"CrF 콘덴서 예비 충전","en":"CrF: capacitor pre-charge"},{"value":13,"ko":"LFF 4~20 mA 손실","en":"LFF: 4-20 mA loss"},{"value":16,"ko":"OHF 드라이브 과열","en":"OHF: drive overheating"},{"value":17,"ko":"OLF 모터 과부하","en":"OLF: motor overload"},{"value":18,"ko":"ObF 직류 버스 과전압","en":"ObF: DC bus overvoltage"},{"value":19,"ko":"OSF 전원 과전압","en":"OSF: line supply overvoltage"},{"value":20,"ko":"OPF 모터 결상","en":"OPF: motor phase loss"},{"value":21,"ko":"PHF 전원 결상","en":"PHF: line phase loss"},{"value":22,"ko":"USF 전원 저전압","en":"USF: line supply undervoltage"},{"value":23,"ko":"SCF 모터 단락(상간)","en":"SCF: motor short-circuit (phase to phase)"},{"value":24,"ko":"SOF 모터 과속","en":"SOF: motor overspeed"},{"value":25,"ko":"tnF 오토 튜닝 실패","en":"tnF: auto-tuning unsuccessful"},{"value":26,"ko":"IF1 알 수 없는 정격","en":"IF1: unknown rating"},{"value":27,"ko":"IF2 MMI 카드","en":"IF2: MMI card"},{"value":28,"ko":"IF3 MMI 통신","en":"IF3: MMI communication"},{"value":29,"ko":"IF4 산업용 EEPROM","en":"IF4: industrial EEPROM"},{"value":30,"ko":"EEF EEPROM 메모리","en":"EEF: EEPROM memory"},{"value":31,"ko":"SCF 임박 단락","en":"SCF: impeding short-circuit"},{"value":32,"ko":"SCF 모터 지락","en":"SCF: motor short-circuit (to ground)"},{"value":33,"ko":"OPF 모터 3상 결상","en":"OPF: motor phase loss, 3 phases"},{"value":34,"ko":"COF 통신 끊김(CANopen)","en":"COF: communication interruption (CANopen)"},{"value":35,"ko":"bLF 브레이크 제어","en":"bLF: brake control"},{"value":36,"ko":"OCF 파워 모듈(ATV312·D15·)","en":"OCF: power module (ATV312·D15·)"},{"value":55,"ko":"SCF 전원 투입 시 파워 모듈·모터 단락","en":"SCF: power module or motor short-circuit at power up"}],"description":{"ko":"LFt 와 같은 코드","en":"Same codes as LFt"},"ref":"p.24","source":1},{"table":"holding-registers","address":7202,"manualAddress":"7202","type":"u16","name":{"ko":"DP2 지난 고장 2","en":"DP2 past detected fault 2"},"access":"r","fc":[3],"values":[{"value":0,"ko":"nOF 고장 기록 없음","en":"nOF: no fault code saved"},{"value":3,"ko":"CFF 설정 오류","en":"CFF: incorrect configuration"},{"value":4,"ko":"CFI 잘못된 설정","en":"CFI: invalid configuration"},{"value":5,"ko":"SLF Modbus 통신 끊김","en":"SLF: Modbus communication interruption"},{"value":6,"ko":"ILF 내부 통신 끊김","en":"ILF: internal communication interruption"},{"value":7,"ko":"CnF 통신 옵션 카드","en":"CnF: communication option card"},{"value":8,"ko":"EPF 외부 고장","en":"EPF: external fault"},{"value":9,"ko":"OCF 과전류","en":"OCF: overcurrent"},{"value":10,"ko":"CrF 콘덴서 예비 충전","en":"CrF: capacitor pre-charge"},{"value":13,"ko":"LFF 4~20 mA 손실","en":"LFF: 4-20 mA loss"},{"value":16,"ko":"OHF 드라이브 과열","en":"OHF: drive overheating"},{"value":17,"ko":"OLF 모터 과부하","en":"OLF: motor overload"},{"value":18,"ko":"ObF 직류 버스 과전압","en":"ObF: DC bus overvoltage"},{"value":19,"ko":"OSF 전원 과전압","en":"OSF: line supply overvoltage"},{"value":20,"ko":"OPF 모터 결상","en":"OPF: motor phase loss"},{"value":21,"ko":"PHF 전원 결상","en":"PHF: line phase loss"},{"value":22,"ko":"USF 전원 저전압","en":"USF: line supply undervoltage"},{"value":23,"ko":"SCF 모터 단락(상간)","en":"SCF: motor short-circuit (phase to phase)"},{"value":24,"ko":"SOF 모터 과속","en":"SOF: motor overspeed"},{"value":25,"ko":"tnF 오토 튜닝 실패","en":"tnF: auto-tuning unsuccessful"},{"value":26,"ko":"IF1 알 수 없는 정격","en":"IF1: unknown rating"},{"value":27,"ko":"IF2 MMI 카드","en":"IF2: MMI card"},{"value":28,"ko":"IF3 MMI 통신","en":"IF3: MMI communication"},{"value":29,"ko":"IF4 산업용 EEPROM","en":"IF4: industrial EEPROM"},{"value":30,"ko":"EEF EEPROM 메모리","en":"EEF: EEPROM memory"},{"value":31,"ko":"SCF 임박 단락","en":"SCF: impeding short-circuit"},{"value":32,"ko":"SCF 모터 지락","en":"SCF: motor short-circuit (to ground)"},{"value":33,"ko":"OPF 모터 3상 결상","en":"OPF: motor phase loss, 3 phases"},{"value":34,"ko":"COF 통신 끊김(CANopen)","en":"COF: communication interruption (CANopen)"},{"value":35,"ko":"bLF 브레이크 제어","en":"bLF: brake control"},{"value":36,"ko":"OCF 파워 모듈(ATV312·D15·)","en":"OCF: power module (ATV312·D15·)"},{"value":55,"ko":"SCF 전원 투입 시 파워 모듈·모터 단락","en":"SCF: power module or motor short-circuit at power up"}],"description":{"ko":"LFt 와 같은 코드","en":"Same codes as LFt"},"ref":"p.24","source":1},{"table":"holding-registers","address":7203,"manualAddress":"7203","type":"u16","name":{"ko":"DP3 지난 고장 3","en":"DP3 past detected fault 3"},"access":"r","fc":[3],"values":[{"value":0,"ko":"nOF 고장 기록 없음","en":"nOF: no fault code saved"},{"value":3,"ko":"CFF 설정 오류","en":"CFF: incorrect configuration"},{"value":4,"ko":"CFI 잘못된 설정","en":"CFI: invalid configuration"},{"value":5,"ko":"SLF Modbus 통신 끊김","en":"SLF: Modbus communication interruption"},{"value":6,"ko":"ILF 내부 통신 끊김","en":"ILF: internal communication interruption"},{"value":7,"ko":"CnF 통신 옵션 카드","en":"CnF: communication option card"},{"value":8,"ko":"EPF 외부 고장","en":"EPF: external fault"},{"value":9,"ko":"OCF 과전류","en":"OCF: overcurrent"},{"value":10,"ko":"CrF 콘덴서 예비 충전","en":"CrF: capacitor pre-charge"},{"value":13,"ko":"LFF 4~20 mA 손실","en":"LFF: 4-20 mA loss"},{"value":16,"ko":"OHF 드라이브 과열","en":"OHF: drive overheating"},{"value":17,"ko":"OLF 모터 과부하","en":"OLF: motor overload"},{"value":18,"ko":"ObF 직류 버스 과전압","en":"ObF: DC bus overvoltage"},{"value":19,"ko":"OSF 전원 과전압","en":"OSF: line supply overvoltage"},{"value":20,"ko":"OPF 모터 결상","en":"OPF: motor phase loss"},{"value":21,"ko":"PHF 전원 결상","en":"PHF: line phase loss"},{"value":22,"ko":"USF 전원 저전압","en":"USF: line supply undervoltage"},{"value":23,"ko":"SCF 모터 단락(상간)","en":"SCF: motor short-circuit (phase to phase)"},{"value":24,"ko":"SOF 모터 과속","en":"SOF: motor overspeed"},{"value":25,"ko":"tnF 오토 튜닝 실패","en":"tnF: auto-tuning unsuccessful"},{"value":26,"ko":"IF1 알 수 없는 정격","en":"IF1: unknown rating"},{"value":27,"ko":"IF2 MMI 카드","en":"IF2: MMI card"},{"value":28,"ko":"IF3 MMI 통신","en":"IF3: MMI communication"},{"value":29,"ko":"IF4 산업용 EEPROM","en":"IF4: industrial EEPROM"},{"value":30,"ko":"EEF EEPROM 메모리","en":"EEF: EEPROM memory"},{"value":31,"ko":"SCF 임박 단락","en":"SCF: impeding short-circuit"},{"value":32,"ko":"SCF 모터 지락","en":"SCF: motor short-circuit (to ground)"},{"value":33,"ko":"OPF 모터 3상 결상","en":"OPF: motor phase loss, 3 phases"},{"value":34,"ko":"COF 통신 끊김(CANopen)","en":"COF: communication interruption (CANopen)"},{"value":35,"ko":"bLF 브레이크 제어","en":"bLF: brake control"},{"value":36,"ko":"OCF 파워 모듈(ATV312·D15·)","en":"OCF: power module (ATV312·D15·)"},{"value":55,"ko":"SCF 전원 투입 시 파워 모듈·모터 단락","en":"SCF: power module or motor short-circuit at power up"}],"description":{"ko":"LFt 와 같은 코드","en":"Same codes as LFt"},"ref":"p.24","source":1},{"table":"holding-registers","address":7204,"manualAddress":"7204","type":"u16","name":{"ko":"DP4 지난 고장 4","en":"DP4 past detected fault 4"},"access":"r","fc":[3],"values":[{"value":0,"ko":"nOF 고장 기록 없음","en":"nOF: no fault code saved"},{"value":3,"ko":"CFF 설정 오류","en":"CFF: incorrect configuration"},{"value":4,"ko":"CFI 잘못된 설정","en":"CFI: invalid configuration"},{"value":5,"ko":"SLF Modbus 통신 끊김","en":"SLF: Modbus communication interruption"},{"value":6,"ko":"ILF 내부 통신 끊김","en":"ILF: internal communication interruption"},{"value":7,"ko":"CnF 통신 옵션 카드","en":"CnF: communication option card"},{"value":8,"ko":"EPF 외부 고장","en":"EPF: external fault"},{"value":9,"ko":"OCF 과전류","en":"OCF: overcurrent"},{"value":10,"ko":"CrF 콘덴서 예비 충전","en":"CrF: capacitor pre-charge"},{"value":13,"ko":"LFF 4~20 mA 손실","en":"LFF: 4-20 mA loss"},{"value":16,"ko":"OHF 드라이브 과열","en":"OHF: drive overheating"},{"value":17,"ko":"OLF 모터 과부하","en":"OLF: motor overload"},{"value":18,"ko":"ObF 직류 버스 과전압","en":"ObF: DC bus overvoltage"},{"value":19,"ko":"OSF 전원 과전압","en":"OSF: line supply overvoltage"},{"value":20,"ko":"OPF 모터 결상","en":"OPF: motor phase loss"},{"value":21,"ko":"PHF 전원 결상","en":"PHF: line phase loss"},{"value":22,"ko":"USF 전원 저전압","en":"USF: line supply undervoltage"},{"value":23,"ko":"SCF 모터 단락(상간)","en":"SCF: motor short-circuit (phase to phase)"},{"value":24,"ko":"SOF 모터 과속","en":"SOF: motor overspeed"},{"value":25,"ko":"tnF 오토 튜닝 실패","en":"tnF: auto-tuning unsuccessful"},{"value":26,"ko":"IF1 알 수 없는 정격","en":"IF1: unknown rating"},{"value":27,"ko":"IF2 MMI 카드","en":"IF2: MMI card"},{"value":28,"ko":"IF3 MMI 통신","en":"IF3: MMI communication"},{"value":29,"ko":"IF4 산업용 EEPROM","en":"IF4: industrial EEPROM"},{"value":30,"ko":"EEF EEPROM 메모리","en":"EEF: EEPROM memory"},{"value":31,"ko":"SCF 임박 단락","en":"SCF: impeding short-circuit"},{"value":32,"ko":"SCF 모터 지락","en":"SCF: motor short-circuit (to ground)"},{"value":33,"ko":"OPF 모터 3상 결상","en":"OPF: motor phase loss, 3 phases"},{"value":34,"ko":"COF 통신 끊김(CANopen)","en":"COF: communication interruption (CANopen)"},{"value":35,"ko":"bLF 브레이크 제어","en":"bLF: brake control"},{"value":36,"ko":"OCF 파워 모듈(ATV312·D15·)","en":"OCF: power module (ATV312·D15·)"},{"value":55,"ko":"SCF 전원 투입 시 파워 모듈·모터 단락","en":"SCF: power module or motor short-circuit at power up"}],"description":{"ko":"LFt 와 같은 코드","en":"Same codes as LFt"},"ref":"p.24","source":1},{"table":"holding-registers","address":8501,"manualAddress":"8501","type":"u16","name":{"ko":"CMD 명령 워드","en":"CMD control word"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"스위치 온(1)","en":"Switch on (1)"},{"bit":1,"ko":"전압 차단(0 에서 동작)","en":"Disable voltage (active at 0)"},{"bit":2,"ko":"퀵 스톱(0 에서 동작)","en":"Quick stop (active at 0)"},{"bit":3,"ko":"운전 가능(1)","en":"Enable operation (1)"},{"bit":7,"ko":"고장 리셋(0→1)","en":"Fault state reset (0 -> 1)"},{"bit":11,"ko":"역방향 지령","en":"Reverse direction command"},{"bit":12,"ko":"Stt 에 따른 정지","en":"Stop according to Stt"},{"bit":13,"ko":"직류 제동 정지(LAC = L1·L2)","en":"DC injection stop (LAC = L1/L2)"},{"bit":14,"ko":"고속 정지(LAC = L1·L2)","en":"Fast stop (LAC = L1/L2)"}],"description":{"ko":"값 예: 0006h 셧다운, 0007h 스위치 온, 000Fh 정방향 운전, 080Fh 역방향, 100Fh 정지, 0000h 전압 차단, 0002h 퀵 스톱, 0080h 고장 리셋 (p.10, p.12). LAC = L3 이면 비트 11~15 를 다른 기능에 배정할 수 있다","en":"Examples: 0006h shutdown, 0007h switch on, 000Fh forward, 080Fh reverse, 100Fh stop, 0000h disable voltage, 0002h quick stop, 0080h fault reset (p.10, p.12). With LAC = L3 bits 11-15 can be assigned to other functions"},"ref":"p.19","source":1},{"table":"holding-registers","address":8502,"manualAddress":"8502","type":"s16","name":{"ko":"LFr 버스 주파수 기준","en":"LFr frequency reference via the bus"},"unit":"Hz","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"CMI 비트 9 = 0(출하) 일 때 0.1 Hz. 비트 9 = 1 이면 32767 = 600 Hz","en":"0.1 Hz when CMI bit 9 = 0 (factory). With bit 9 = 1, 32767 = 600 Hz"},"ref":"p.19","source":1},{"table":"holding-registers","address":8503,"manualAddress":"8503","type":"u16","name":{"ko":"PISP 버스 PI 기준","en":"PISP PI regulator reference via the bus"},"unit":"%","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0,"max":100},"ref":"p.19","source":1},{"table":"holding-registers","address":8504,"manualAddress":"8504","type":"u16","name":{"ko":"CMI 확장 명령 워드","en":"CMI extended control word"},"access":"rw","fc":[3,6,16],"bits":[{"bit":0,"ko":"출하 설정 불러오기(정지 중)","en":"Recall factory settings (at standstill)"},{"bit":1,"ko":"EEPROM 에 저장","en":"Save configuration to EEPROM"},{"bit":3,"ko":"외부 고장","en":"External fault"},{"bit":4,"ko":"램프 전환","en":"Ramp switching command"},{"bit":9,"ko":"고분해능(32767 = 600 Hz)","en":"High resolution (32767 = 600 Hz)"},{"bit":13,"ko":"정지 중 잠금","en":"Drive locked on standstill"},{"bit":14,"ko":"Modbus 통신 감시 끔(NTO)","en":"No Modbus communication monitoring (NTO)"},{"bit":15,"ko":"정합성 검사 안 함 + 정지 중 잠금","en":"No parameter consistency check + locked on standstill"}],"description":{"ko":"비트 0·1 은 처리되면 0 으로 돌아간다. EEPROM 쓰기 수명 100만 회","en":"Bits 0 and 1 reset to 0 automatically. EEPROM life 1,000,000 writes"},"ref":"p.20","source":1},{"table":"holding-registers","address":9630,"manualAddress":"9630","type":"u16","name":{"ko":"tHr 모터 열 상태","en":"tHr motor thermal state"},"unit":"%","access":"r","fc":[3],"description":{"ko":"100% = 정격, 118% = OLF 문턱","en":"100% = nominal, 118% = OLF threshold"},"ref":"p.21","source":1},{"table":"holding-registers","address":12002,"manualAddress":"12002","type":"u32","order":"CDAB","name":{"ko":"USPL·USPH 고객 단위 모터 속도","en":"USPL/USPH motor speed in customer units"},"access":"r","fc":[3],"description":{"ko":"12002 하위·12003 상위 워드. rFr × SdS","en":"12002 low word, 12003 high word. rFr × SdS"},"ref":"p.22","source":1}],"sources":[{"title":"Altivar 312 Modbus Communication Manual","publisher":"Schneider Electric","edition":{"ko":"BBV52816 04/2009","en":"BBV52816 04/2009"},"url":"https://download.schneider-electric.com/files?p_Doc_Ref=BBV52816","pages":{"ko":"통신 설정 p.9·p.11, Modbus 함수·예 p.12~14","en":"Communication settings p.9, p.11; Modbus functions and examples pp.12-14"},"checked":"2026-10-24"},{"title":"Altivar 312 Communication Variables Manual","publisher":"Schneider Electric","edition":{"ko":"BBV51701 06/2009","en":"BBV51701 06/2009"},"url":"https://download.schneider-electric.com/files?p_Doc_Ref=BBV51701","pages":{"ko":"상태 기계 p.10~13, 제어 변수 p.19~20, 감시 변수 p.21~25, 설정 변수 p.27~56","en":"State machine pp.10-13, control variables pp.19-20, monitoring variables pp.21-25, configuration variables pp.27-56"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"schneider-electric/atv320","manufacturer":{"ko":"슈나이더 일렉트릭","en":"Schneider Electric"},"model":"ATV320","models":["Altivar Machine 320"],"kind":"inverter","title":{"ko":"슈나이더 일렉트릭 Altivar Machine 320 (ATV320) 인버터 (Modbus RTU)","en":"Schneider Electric Altivar Machine 320 (ATV320) drive (Modbus RTU)"},"summary":{"ko":"내장 Modbus RTU. 논리 주소 = 프레임 주소: 통신 설정 6001~6005, 가감속 시간 9001·9002, 통신 스캐너 12701~12768(출하 상태 입력 ETA·RFRD, 출력 CMD·LFRD)","en":"Embedded Modbus RTU. Logical address = frame address: communication settings 6001-6005, acceleration/deceleration time 9001/9002, communication scanner 12701-12768 (factory: inputs ETA and RFRD, outputs CMD and LFRD)"},"protocols":["rtu"],"comm":{"baud":19200,"bauds":[4800,9600,19200,38400],"dataBits":8,"parity":"even","stopBits":1,"unitRange":[1,247],"maxRegisters":63,"addressing":"zero","notes":[{"ko":"주소 체계: 매뉴얼 읽기 예(p.19)는 02 03 0C 1E 00 04 27 6C 로 W3102~W3105 를 읽고 02 03 08 00 28 02 58 01 F4 00 00 52 B0 을 받는다(매뉴얼 표에는 개수가 «004» 로 한 자리 빠져 있음). 쓰기 예는 02 06 23 29 00 0D 92 70 (W9001, p.19), FC16 예는 02 10 23 29 00 02 04 00 14 00 1E 73 A4 → 02 10 23 29 00 02 9B B7 (p.20). 매뉴얼 번호 = 프레임 주소(0 기준). CRC 모두 계산값과 맞다.","en":"Addressing: the read example (p.19) sends 02 03 0C 1E 00 04 27 6C to read W3102-W3105 and gets 02 03 08 00 28 02 58 01 F4 00 00 52 B0 (the manual table prints the count as «004», one digit short). The write example is 02 06 23 29 00 0D 92 70 (W9001, p.19) and the FC16 example 02 10 23 29 00 02 04 00 14 00 1E 73 A4 -> 02 10 23 29 00 02 9B B7 (p.20). Manual number = frame address (0-based). All CRCs match calculation."},{"ko":"출하값: Add = OFF(국번 없음 — 응답하려면 1~247 로), tbr 19.2 kbps, tFO 8E1, tto 10 s (p.32-33). 8O1·8E1·8N1·8N2 와 4.8~38.4 kbps 를 고를 수 있다. 바꾼 통신 설정은 전원을 다시 켜야 반영된다 (p.31).","en":"Factory settings: Add = OFF (no address assigned; set 1-247 to get replies), tbr 19.2 kbps, tFO 8E1, tto 10 s (pp.32-33). 8O1/8E1/8N1/8N2 and 4.8-38.4 kbps selectable. Changed communication settings take effect after a power cycle (p.31)."},{"ko":"함수 코드 03(최대 63워드)·06·16(최대 61워드)·23(읽기 20·쓰기 20워드)·43/14(장치 식별)·08 (p.18).","en":"Function codes 03 (up to 63 words), 06, 16 (up to 61 words), 23 (20 read + 20 write words), 43/14 (device identification) and 08 (p.18)."}]},"registers":[{"table":"holding-registers","address":3102,"manualAddress":"3102","type":"u16","name":{"ko":"SFr 스위칭 주파수","en":"SFr switching frequency"},"unit":"kHz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 4 kHz = 0028h","en":"Manual read example: 4 kHz = 0028h"},"ref":"p.19","source":0},{"table":"holding-registers","address":3103,"manualAddress":"3103","type":"u16","name":{"ko":"tFr 최대 출력 주파수","en":"tFr maximum output frequency"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 60 Hz = 0258h","en":"Manual read example: 60 Hz = 0258h"},"ref":"p.19","source":0},{"table":"holding-registers","address":3104,"manualAddress":"3104","type":"u16","name":{"ko":"HSP 고속","en":"HSP high speed"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 50 Hz = 01F4h","en":"Manual read example: 50 Hz = 01F4h"},"ref":"p.19","source":0},{"table":"holding-registers","address":3105,"manualAddress":"3105","type":"u16","name":{"ko":"LSP 저속","en":"LSP low speed"},"unit":"Hz","scale":0.1,"access":"r","fc":[3],"description":{"ko":"매뉴얼 읽기 예: 0 Hz = 0000h","en":"Manual read example: 0 Hz = 0000h"},"ref":"p.19","source":0},{"table":"holding-registers","address":6001,"manualAddress":"6001","type":"u16","name":{"ko":"Add Modbus 국번","en":"Add Modbus address"},"access":"rw","fc":[3,6,16],"range":{"min":0,"max":247},"values":[{"value":0,"ko":"OFF — 국번 없음(출하값)","en":"OFF: no address assigned (factory setting)"}],"description":{"ko":"1~247. 바꾼 통신 설정은 전원을 다시 켠 뒤 반영","en":"1-247. Changed communication settings take effect after a power cycle"},"ref":"p.31, p.32","source":0},{"table":"holding-registers","address":6003,"manualAddress":"6003","type":"u16","name":{"ko":"tbr Modbus 통신 속도","en":"tbr Modbus baud rate"},"access":"rw","fc":[3,6,16],"values":[{"value":24,"ko":"4800 bps","en":"4800 bps"},{"value":28,"ko":"9600 bps","en":"9600 bps"},{"value":32,"ko":"19200 bps(출하값)","en":"19200 bps (factory setting)"},{"value":36,"ko":"38400 bps","en":"38400 bps"}],"ref":"p.32","source":0},{"table":"holding-registers","address":6004,"manualAddress":"6004","type":"u16","name":{"ko":"tFO Modbus 데이터 형식","en":"tFO Modbus data format"},"access":"rw","fc":[3,6,16],"values":[{"value":2,"ko":"8O1","en":"8O1"},{"value":3,"ko":"8E1(출하값)","en":"8E1 (factory setting)"},{"value":4,"ko":"8N1","en":"8N1"},{"value":5,"ko":"8N2","en":"8N2"}],"ref":"p.32","source":0},{"table":"holding-registers","address":6005,"manualAddress":"6005","type":"u16","name":{"ko":"tto Modbus 타임아웃","en":"tto Modbus timeout"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"range":{"min":0.1,"max":30},"description":{"ko":"출하값 10 s. 시간 안에 요청이 없으면 SLF1 고장","en":"Factory setting 10 s. SLF1 fault if no request arrives within the time"},"ref":"p.33, p.80","source":0},{"table":"holding-registers","address":6010,"manualAddress":"6010","type":"u16","name":{"ko":"M1EC Modbus CRC 오류 수","en":"M1EC Modbus CRC error count"},"access":"r","fc":[3],"description":{"ko":"65535 에서 멈춘다","en":"Stops at 65535"},"ref":"p.74","source":0},{"table":"holding-registers","address":6011,"manualAddress":"6011","type":"u16","name":{"ko":"M1Ct Modbus 받은 프레임 수","en":"M1Ct Modbus frames received"},"access":"r","fc":[3],"description":{"ko":"맞는·틀린 프레임 모두 센다. 65535 다음 0","en":"Counts correct and incorrect frames. Wraps from 65535 to 0"},"ref":"p.74","source":0},{"table":"holding-registers","address":9001,"manualAddress":"9001","type":"u16","name":{"ko":"ACC 가속 시간","en":"ACC acceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 쓰기 예: 1.3 s = 000Dh(FC06), 2 s = 20(FC16)","en":"Manual write examples: 1.3 s = 000Dh (FC06), 2 s = 20 (FC16)"},"ref":"p.19, p.20","source":0},{"table":"holding-registers","address":9002,"manualAddress":"9002","type":"u16","name":{"ko":"DEC 감속 시간","en":"DEC deceleration time"},"unit":"s","scale":0.1,"access":"rw","fc":[3,6,16],"description":{"ko":"매뉴얼 쓰기 예: 3 s = 30(FC16)","en":"Manual write example: 3 s = 30 (FC16)"},"ref":"p.20","source":0},{"table":"holding-registers","address":12701,"manualAddress":"12701","type":"u16","name":{"ko":"nMA1 입력 1번째 말의 원본 주소","en":"nMA1 Source address of the 1st input word"},"access":"r","fc":[3],"description":{"ko":"출하값 ETA(상태 워드)","en":"Factory setting ETA (status word)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12702,"manualAddress":"12702","type":"u16","name":{"ko":"nMA2 입력 2번째 말의 원본 주소","en":"nMA2 Source address of the 2nd input word"},"access":"r","fc":[3],"description":{"ko":"출하값 RFRD(출력 속도)","en":"Factory setting RFRD (output speed)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12703,"manualAddress":"12703","type":"u16","name":{"ko":"nMA3 입력 3번째 말의 원본 주소","en":"nMA3 Source address of the 3rd input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12704,"manualAddress":"12704","type":"u16","name":{"ko":"nMA4 입력 4번째 말의 원본 주소","en":"nMA4 Source address of the 4th input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12705,"manualAddress":"12705","type":"u16","name":{"ko":"nMA5 입력 5번째 말의 원본 주소","en":"nMA5 Source address of the 5th input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12706,"manualAddress":"12706","type":"u16","name":{"ko":"nMA6 입력 6번째 말의 원본 주소","en":"nMA6 Source address of the 6th input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12707,"manualAddress":"12707","type":"u16","name":{"ko":"nMA7 입력 7번째 말의 원본 주소","en":"nMA7 Source address of the 7th input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12708,"manualAddress":"12708","type":"u16","name":{"ko":"nMA8 입력 8번째 말의 원본 주소","en":"nMA8 Source address of the 8th input word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.34","source":0},{"table":"holding-registers","address":12721,"manualAddress":"12721","type":"u16","name":{"ko":"nCA1 출력 1번째 말의 대상 주소","en":"nCA1 Destination address of the 1st output word"},"access":"r","fc":[3],"description":{"ko":"출하값 CMD(명령 워드)","en":"Factory setting CMD (command word)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12722,"manualAddress":"12722","type":"u16","name":{"ko":"nCA2 출력 2번째 말의 대상 주소","en":"nCA2 Destination address of the 2nd output word"},"access":"r","fc":[3],"description":{"ko":"출하값 LFRD(속도 목표)","en":"Factory setting LFRD (speed target)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12723,"manualAddress":"12723","type":"u16","name":{"ko":"nCA3 출력 3번째 말의 대상 주소","en":"nCA3 Destination address of the 3rd output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12724,"manualAddress":"12724","type":"u16","name":{"ko":"nCA4 출력 4번째 말의 대상 주소","en":"nCA4 Destination address of the 4th output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12725,"manualAddress":"12725","type":"u16","name":{"ko":"nCA5 출력 5번째 말의 대상 주소","en":"nCA5 Destination address of the 5th output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12726,"manualAddress":"12726","type":"u16","name":{"ko":"nCA6 출력 6번째 말의 대상 주소","en":"nCA6 Destination address of the 6th output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12727,"manualAddress":"12727","type":"u16","name":{"ko":"nCA7 출력 7번째 말의 대상 주소","en":"nCA7 Destination address of the 7th output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12728,"manualAddress":"12728","type":"u16","name":{"ko":"nCA8 출력 8번째 말의 대상 주소","en":"nCA8 Destination address of the 8th output word"},"access":"r","fc":[3],"description":{"ko":"출하값 0(없음)","en":"Factory setting 0 (none)"},"ref":"p.35","source":0},{"table":"holding-registers","address":12741,"manualAddress":"12741","type":"u16","name":{"ko":"nM1 입력 1번째 말 값","en":"nM1 value of input word 1"},"access":"r","fc":[3],"description":{"ko":"출하 상태 ETA(상태 워드) 값. nMA1 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Factory: ETA (status word) value. Value at the address in nMA1. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12742,"manualAddress":"12742","type":"u16","name":{"ko":"nM2 입력 2번째 말 값","en":"nM2 value of input word 2"},"access":"r","fc":[3],"description":{"ko":"출하 상태 RFRD(출력 속도) 값. nMA2 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Factory: RFRD (output speed) value. Value at the address in nMA2. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12743,"manualAddress":"12743","type":"u16","name":{"ko":"nM3 입력 3번째 말 값","en":"nM3 value of input word 3"},"access":"r","fc":[3],"description":{"ko":"nMA3 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Value at the address in nMA3. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12744,"manualAddress":"12744","type":"u16","name":{"ko":"nM4 입력 4번째 말 값","en":"nM4 value of input word 4"},"access":"r","fc":[3],"description":{"ko":"nMA4 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Value at the address in nMA4. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12745,"manualAddress":"12745","type":"u16","name":{"ko":"nM5 입력 5번째 말 값","en":"nM5 value of input word 5"},"access":"r","fc":[3],"description":{"ko":"nMA5 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Value at the address in nMA5. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12746,"manualAddress":"12746","type":"u16","name":{"ko":"nM6 입력 6번째 말 값","en":"nM6 value of input word 6"},"access":"r","fc":[3],"description":{"ko":"nMA6 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Value at the address in nMA6. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12747,"manualAddress":"12747","type":"u16","name":{"ko":"nM7 입력 7번째 말 값","en":"nM7 value of input word 7"},"access":"r","fc":[3],"description":{"ko":"nMA7 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Value at the address in nMA7. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12748,"manualAddress":"12748","type":"u16","name":{"ko":"nM8 입력 8번째 말 값","en":"nM8 value of input word 8"},"access":"r","fc":[3],"description":{"ko":"nMA8 이 가리키는 값. 매뉴얼 응용 예는 12741 부터 4개를 읽는다","en":"Value at the address in nMA8. The manual application example reads 4 words from 12741"},"ref":"p.36, p.63","source":0},{"table":"holding-registers","address":12761,"manualAddress":"12761","type":"u16","name":{"ko":"nC1 출력 1번째 말 값","en":"nC1 value of output word 1"},"access":"rw","fc":[3,6,16],"description":{"ko":"출하 상태 CMD(명령 워드) 로 간다. nCA1 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Factory: goes to CMD (command word). Written to the address in nCA1. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12762,"manualAddress":"12762","type":"u16","name":{"ko":"nC2 출력 2번째 말 값","en":"nC2 value of output word 2"},"access":"rw","fc":[3,6,16],"description":{"ko":"출하 상태 LFRD(속도 목표) 로 간다. nCA2 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Factory: goes to LFRD (speed target). Written to the address in nCA2. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12763,"manualAddress":"12763","type":"u16","name":{"ko":"nC3 출력 3번째 말 값","en":"nC3 value of output word 3"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA3 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Written to the address in nCA3. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12764,"manualAddress":"12764","type":"u16","name":{"ko":"nC4 출력 4번째 말 값","en":"nC4 value of output word 4"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA4 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Written to the address in nCA4. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12765,"manualAddress":"12765","type":"u16","name":{"ko":"nC5 출력 5번째 말 값","en":"nC5 value of output word 5"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA5 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Written to the address in nCA5. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12766,"manualAddress":"12766","type":"u16","name":{"ko":"nC6 출력 6번째 말 값","en":"nC6 value of output word 6"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA6 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Written to the address in nCA6. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12767,"manualAddress":"12767","type":"u16","name":{"ko":"nC7 출력 7번째 말 값","en":"nC7 value of output word 7"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA7 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Written to the address in nCA7. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0},{"table":"holding-registers","address":12768,"manualAddress":"12768","type":"u16","name":{"ko":"nC8 출력 8번째 말 값","en":"nC8 value of output word 8"},"access":"rw","fc":[3,6,16],"description":{"ko":"nCA8 이 가리키는 곳에 쓰인다. 매뉴얼 응용 예는 12761 부터 4개를 FC23(17h)으로 쓴다","en":"Written to the address in nCA8. The manual application example writes 4 words from 12761 with FC23 (17h)"},"ref":"p.37, p.63","source":0}],"notes":[{"ko":"이 매뉴얼에 주소와 단위·값이 나온 레지스터만 넣었다. 명령 워드 CMD·상태 워드 ETA·속도(LFRD·RFRD)의 Modbus 주소는 이 매뉴얼에 없어(통신 스캐너 출하 배정으로만 나옴) 따로 넣지 않았다 — 출하 상태 그대로면 nC1·nC2(12761·12762)로 CMD·LFRD 를 쓰고 nM1·nM2(12741·12742)로 ETA·RFRD 를 읽는다. 나머지 파라미터 주소는 통신 파라미터 엑셀(NVE41316)에 있어 넣지 않았다.","en":"Only registers whose address and unit/values are in this manual are included. The Modbus addresses of the command word CMD, status word ETA and speeds (LFRD, RFRD) are not in this manual (they appear only as communication scanner factory assignments), so they are not listed separately; with factory settings, write CMD and LFRD through nC1/nC2 (12761/12762) and read ETA and RFRD through nM1/nM2 (12741/12742). Other parameter addresses are in the communication parameters spreadsheet (NVE41316) and are left out."},{"ko":"매뉴얼은 통신 설정(6001~6005)만 «읽기/쓰기 파라미터» 라고 적어, 그 밖에 쓰기가 예로 확인된 9001·9002·nC1~8 말고는 읽기(r)로 적었다(nMA·nCA 는 설정 메뉴에서 바꾸는 값).","en":"The manual states read/write access only for the communication settings (6001-6005), so apart from 9001/9002 and nC1-8 (writes shown in examples) everything is listed as read (r); nMA/nCA are set from the menus."}],"sources":[{"title":"Altivar Machine 320 Variable Speed Drives for Synchronous and Asynchronous Motors Modbus Serial Link Manual","publisher":"Schneider Electric","edition":{"ko":"NVE41308.01 04/2016","en":"NVE41308.01 04/2016"},"url":"https://download.se.com/files?p_Doc_Ref=NVE41308&p_enDocType=User+guide&p_File_Name=ATV320_Modbus_manual_EN_NVE41308_01.pdf","pages":{"ko":"Modbus 함수·예 p.18-20, 통신 설정 p.31-33, 통신 스캐너 p.34-37, 응용 예 p.63, Modbus 진단 p.74","en":"Modbus functions and examples pp.18-20, communication settings pp.31-33, communication scanner pp.34-37, application example p.63, Modbus diagnostics p.74"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"yaskawa/a1000","manufacturer":{"ko":"야스카와","en":"YASKAWA"},"model":"A1000","models":["CIMR-AUA"],"kind":"inverter","title":{"ko":"야스카와 A1000 인버터 (내장 MEMOBUS/Modbus)","en":"YASKAWA A1000 AC drive (built-in MEMOBUS/Modbus)"},"summary":{"ko":"내장 RS-422/485 MEMOBUS/Modbus RTU. 지령 0001H~, 모니터 0020H~, Enter 명령 0900H·0910H","en":"Built-in RS-422/485 MEMOBUS/Modbus RTU. Commands from 0001H, monitors from 0020H, Enter commands 0900H/0910H"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400,57600,76800,115200],"dataBits":8,"parity":"none","stopBits":1,"unit":31,"unitRange":[1,255],"maxRegisters":16,"addressing":"zero","notes":[{"ko":"주소 체계: 읽기 예(p.714)는 국번 02, FC03, 시작 00 20, 개수 00 04, CRC 45 F0 으로 0020H(드라이브 상태 1)부터 읽고, 쓰기 예(p.715)는 FC10 시작 00 01, 2개로 0001H 에 0001h(정방향 운전)·0002H 에 1770h(60.00 Hz)를 쓴다. 매뉴얼 주소 = 프레임 주소. (쓰기 예의 CRC 는 매뉴얼에 63 39 로 적혀 있으나 계산값은 6D B7 — 주소와는 무관)","en":"Addressing: the read example (p.714) sends slave 02, FC03, start 00 20, count 00 04, CRC 45 F0 to read from 0020H (drive status 1); the write example (p.715) sends FC10 start 00 01, 2 registers, writing 0001h (forward run) to 0001H and 1770h (60.00 Hz) to 0002H. Manual address = frame address. (The write example's CRC is printed as 63 39 but computes to 6D B7; this does not affect addressing.)"},{"ko":"함수 코드는 03H(읽기, 한 번에 16개까지)·08H(루프백)·10H(여러 개 쓰기)뿐 — 06H 없음 (p.712, p.714).","en":"Only function codes 03H (read, up to 16 registers), 08H (loopback) and 10H (write multiple) — no 06H (p.712, p.714)."},{"ko":"초기값: H5-01 국번 1F(31), 0~FF(0 이면 응답 없음); H5-02 3 = 9600 bps(0~8 = 1200~115200); H5-03 0 = 패리티 없음; 데이터 8비트·정지 1비트 고정, RTU 만 (p.703, p.707). 변경 후 전원 재투입.","en":"Defaults: H5-01 address 1F (31), range 0-FF (0 = no response); H5-02 3 = 9600 bps (0-8 = 1200-115200); H5-03 0 = no parity; 8 data bits and 1 stop bit fixed, RTU only (p.703, p.707). Cycle power after changes."},{"ko":"매뉴얼이 «ov» 를 «Drive Overheat Warning (ov)» 로 적은 곳(0021H bit 1, 002AH bit 6, 고장 코드 0008H 등)은 이름과 약호가 어긋나 뺐다.","en":"Entries where the manual prints 'ov' as 'Drive Overheat Warning (ov)' (0021H bit 1, 002AH bit 6, fault code 0008H, etc.) are left out because the name and code disagree."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"0001H","type":"u16","name":{"ko":"운전 명령·다기능 입력","en":"Operation commands and multi-function inputs"},"access":"rw","fc":[3,16],"bits":[{"bit":0,"ko":"정방향 운전(H5-12=0) / 운전(H5-12=1)","en":"Forward run (H5-12=0) / Run (H5-12=1)"},{"bit":1,"ko":"역방향 운전(H5-12=0) / 정·역 선택 1=역(H5-12=1)","en":"Reverse run (H5-12=0) / FWD-REV, 1 = reverse (H5-12=1)"},{"bit":2,"ko":"외부 고장(EF0)","en":"External fault (EF0)"},{"bit":3,"ko":"고장 리셋","en":"Fault reset"},{"bit":4,"ko":"다기능 입력 1","en":"Multi-function input 1"},{"bit":5,"ko":"다기능 입력 2","en":"Multi-function input 2"},{"bit":6,"ko":"다기능 입력 3","en":"Multi-function input 3"},{"bit":7,"ko":"다기능 입력 4","en":"Multi-function input 4"},{"bit":8,"ko":"다기능 입력 5","en":"Multi-function input 5"},{"bit":9,"ko":"다기능 입력 6","en":"Multi-function input 6"},{"bit":10,"ko":"다기능 입력 7","en":"Multi-function input 7"},{"bit":11,"ko":"다기능 입력 8","en":"Multi-function input 8"}],"ref":"p.716","source":0},{"table":"holding-registers","address":2,"manualAddress":"0002H","type":"u16","name":{"ko":"주파수 지령","en":"Frequency reference"},"access":"rw","fc":[3,16],"description":{"ko":"단위는 o1-03(0 = 0.01 Hz, 1 = 0.01%, 2 = r/min, 3 = 사용자). o1-03 초기값은 A1-02(제어 방식)에 따라 다르다. 매뉴얼 FC10 예: 60.00 Hz = 1770h (p.715)","en":"Unit set by o1-03 (0 = 0.01 Hz, 1 = 0.01%, 2 = r/min, 3 = user). o1-03 default depends on A1-02 (control mode). Manual FC10 example: 60.00 Hz = 1770h (p.715)"},"ref":"p.716","source":0},{"table":"holding-registers","address":3,"manualAddress":"0003H","type":"u16","name":{"ko":"출력 전압 이득","en":"Output voltage gain"},"unit":"%","scale":0.1,"access":"rw","fc":[3,16],"range":{"min":2,"max":200},"description":{"ko":"전원 투입 시 1000(100.0%)","en":"1000 (100.0%) at power-up"},"ref":"p.716","source":0},{"table":"holding-registers","address":4,"manualAddress":"0004H","type":"s16","name":{"ko":"토크 지령/토크 제한","en":"Torque reference / torque limit"},"unit":"%","scale":0.1,"access":"rw","fc":[3,16],"description":{"ko":"토크 제어가 유효할 때만","en":"Only when torque control is enabled"},"ref":"p.716","source":0},{"table":"holding-registers","address":5,"manualAddress":"0005H","type":"s16","name":{"ko":"토크 보상","en":"Torque compensation"},"unit":"%","scale":0.1,"access":"rw","fc":[3,16],"description":{"ko":"토크 제어가 유효할 때만","en":"Only when torque control is enabled"},"ref":"p.716","source":0},{"table":"holding-registers","address":6,"manualAddress":"0006H","type":"s16","name":{"ko":"PID 목표값","en":"PID target"},"unit":"%","scale":0.01,"access":"rw","fc":[3,16],"ref":"p.716","source":0},{"table":"holding-registers","address":9,"manualAddress":"0009H","type":"u16","name":{"ko":"다기능 디지털 출력 설정","en":"Multi-function digital output settings"},"access":"rw","fc":[3,16],"bits":[{"bit":0,"ko":"접점 출력 1(M1-M2)","en":"Contact output 1 (M1-M2)"},{"bit":1,"ko":"접점 출력 2(M3-M4)","en":"Contact output 2 (M3-M4)"},{"bit":2,"ko":"접점 출력 3(M5-M6)","en":"Contact output 3 (M5-M6)"},{"bit":6,"ko":"bit 7 기능 사용","en":"Enables the function in bit 7"},{"bit":7,"ko":"고장 접점 출력(MA/MB-MC)","en":"Fault contact output (MA/MB-MC)"}],"ref":"p.716","source":0},{"table":"holding-registers","address":32,"manualAddress":"0020H","type":"u16","name":{"ko":"드라이브 상태 1","en":"Drive status 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"역방향 운전 중","en":"During reverse"},{"bit":2,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":3,"ko":"고장","en":"Fault"},{"bit":4,"ko":"데이터 설정 오류","en":"Data setting error"},{"bit":5,"ko":"다기능 접점 출력 1(M1-M2)","en":"Multi-function contact output 1 (M1-M2)"},{"bit":6,"ko":"다기능 접점 출력 2(M3-M4)","en":"Multi-function contact output 2 (M3-M4)"},{"bit":7,"ko":"다기능 접점 출력 3(M5-M6)","en":"Multi-function contact output 3 (M5-M6)"},{"bit":14,"ko":"ComRef 유효","en":"ComRef enabled"},{"bit":15,"ko":"ComCtrl 유효","en":"ComCtrl enabled"}],"ref":"p.717","source":0},{"table":"holding-registers","address":33,"manualAddress":"0021H","type":"u16","name":{"ko":"고장 내용 1","en":"Fault contents 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"과전류(oC)·지락(GF)","en":"Overcurrent (oC), ground fault (GF)"},{"bit":2,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"bit":3,"ko":"과열 1(oH1)·과열 경고(oH2)","en":"Overheat 1 (oH1), drive overheat warning (oH2)"},{"bit":4,"ko":"제동 트랜지스터 고장(rr)·제동 저항 과열(rH)","en":"Braking transistor fault (rr), braking resistor overheat (rH)"},{"bit":6,"ko":"PID 피드백 상실(FbL/FbH)","en":"PID feedback loss (FbL/FbH)"},{"bit":7,"ko":"외부 고장 EF~EF8","en":"External fault EF-EF8"},{"bit":8,"ko":"하드웨어 고장 CPF(oFx 포함)","en":"Hardware fault CPF (incl. oFx)"},{"bit":9,"ko":"모터 과부하(oL1)·과토크(oL3/oL4)·저토크(UL3/UL4)","en":"Motor overload (oL1), overtorque (oL3/oL4), undertorque (UL3/UL4)"},{"bit":10,"ko":"PG 단선(PGo)·PG 하드웨어(PGoH)·과속(oS)·속도 편차(dEv)","en":"PG disconnected (PGo), PG hardware fault (PGoH), overspeed (oS), speed deviation (dEv)"},{"bit":11,"ko":"주회로 저전압(Uv)","en":"Main circuit undervoltage (Uv)"},{"bit":12,"ko":"DC 버스 저전압(Uv1)·제어 전원 이상(Uv2)·저전압 3(Uv3)","en":"DC bus undervoltage (Uv1), control power fault (Uv2), undervoltage 3 (Uv3)"},{"bit":13,"ko":"출력 결상(LF)·입력 결상(PF)","en":"Output phase loss (LF), input phase loss (PF)"},{"bit":14,"ko":"MEMOBUS 통신 오류(CE)·옵션 통신 오류(bUS)","en":"MEMOBUS communication error (CE), option communication error (bUS)"},{"bit":15,"ko":"외부 오퍼레이터 연결 이상(oPr)","en":"External operator connection fault (oPr)"}],"description":{"ko":"bit 1 은 매뉴얼에 «Drive Overheat Warning (ov)» 로 적혀 이름과 약호가 어긋나 뺐다","en":"Bit 1 is printed as 'Drive Overheat Warning (ov)' (name and code disagree), so it is left out"},"ref":"p.717","source":0},{"table":"holding-registers","address":34,"manualAddress":"0022H","type":"u16","name":{"ko":"데이터 링크 상태","en":"Data link status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"데이터 쓰기 중 또는 모터 전환 중","en":"Writing data or switching motors"},{"bit":3,"ko":"상·하한 오류","en":"Upper or lower limit error"},{"bit":4,"ko":"데이터 정합 오류","en":"Data conformity error"},{"bit":5,"ko":"EEPROM 쓰기 중","en":"Writing to EEPROM"},{"bit":6,"ko":"0 = EEPROM 에 쓰기, 1 = RAM 에만(H5-17 = 1 일 때)","en":"0 = write to EEPROM, 1 = RAM only (when H5-17 = 1)"}],"ref":"p.718","source":0},{"table":"holding-registers","address":35,"manualAddress":"0023H","type":"u16","name":{"ko":"주파수 지령(모니터)","en":"Frequency reference (monitor)"},"access":"r","fc":[3],"description":{"ko":"단위는 o1-03 (p.728 주 <1>)","en":"Unit set by o1-03 (p.728 note <1>)"},"ref":"p.718","source":0},{"table":"holding-registers","address":36,"manualAddress":"0024H","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"access":"r","fc":[3],"description":{"ko":"단위는 o1-03 (p.728 주 <1>)","en":"Unit set by o1-03 (p.728 note <1>)"},"ref":"p.718","source":0},{"table":"holding-registers","address":37,"manualAddress":"0025H","type":"u16","name":{"ko":"출력 전압 지령","en":"Output voltage reference"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"단위는 H5-10 으로 정한다(0.1 V 단위)","en":"Units set by H5-10 (0.1 V units)"},"ref":"p.718","source":0},{"table":"holding-registers","address":38,"manualAddress":"0026H","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","access":"r","fc":[3],"description":{"ko":"배율은 형번별: 2A0004~2A0040·4A0002~4A0023 은 0.01 A, 2A0056~2A0415·4A0031~4A0675 는 0.1 A, 4A0930·4A1200 은 1 A","en":"Scale by model: 2A0004-2A0040, 4A0002-4A0023 = 0.01 A; 2A0056-2A0415, 4A0031-4A0675 = 0.1 A; 4A0930, 4A1200 = 1 A"},"ref":"p.718","source":0},{"table":"holding-registers","address":39,"manualAddress":"0027H","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"access":"r","fc":[3],"description":{"ko":"데이터 표에 단위가 없다","en":"No unit given in the data table"},"ref":"p.718","source":0},{"table":"holding-registers","address":40,"manualAddress":"0028H","type":"u16","name":{"ko":"토크 지령","en":"Torque reference"},"access":"r","fc":[3],"description":{"ko":"데이터 표에 단위가 없다","en":"No unit given in the data table"},"ref":"p.718","source":0},{"table":"holding-registers","address":41,"manualAddress":"0029H","type":"u16","name":{"ko":"고장 내용 2","en":"Fault contents 2"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"출력 단락·IGBT 고장(SC)","en":"Output short circuit or IGBT fault (SC)"},{"bit":1,"ko":"지락(GF)","en":"Ground fault (GF)"},{"bit":2,"ko":"입력 결상(PF)","en":"Input phase loss (PF)"},{"bit":3,"ko":"출력 결상(LF)","en":"Output phase loss (LF)"},{"bit":4,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"},{"bit":6,"ko":"모터 과열 2 PTC(oH4)","en":"Motor overheat 2, PTC input (oH4)"}],"ref":"p.718","source":0},{"table":"holding-registers","address":42,"manualAddress":"002AH","type":"u16","name":{"ko":"경보 내용 1","en":"Alarm contents 1"},"access":"r","fc":[3],"bits":[{"bit":2,"ko":"정·역 운전 지령 입력 오류(EF)","en":"Forward/reverse run command input error (EF)"},{"bit":3,"ko":"베이스블록(bb)","en":"Drive baseblock (bb)"},{"bit":4,"ko":"과토크 검출 1(oL3)","en":"Overtorque detection 1 (oL3)"},{"bit":5,"ko":"방열판 과열(oH)","en":"Heatsink overheat (oH)"},{"bit":7,"ko":"저전압(Uv)","en":"Undervoltage (Uv)"},{"bit":8,"ko":"내부 팬 고장(FAn)","en":"Internal fan fault (FAn)"},{"bit":9,"ko":"MEMOBUS 통신 오류(CE)","en":"MEMOBUS communication error (CE)"},{"bit":10,"ko":"옵션 통신 오류(bUS)","en":"Option communication error (bUS)"},{"bit":11,"ko":"저토크 검출 1/2(UL3/UL4)","en":"Undertorque detection 1/2 (UL3/UL4)"},{"bit":12,"ko":"모터 과열(oH3)","en":"Motor overheat (oH3)"},{"bit":13,"ko":"PID 피드백 상실(FbL/FbH)","en":"PID feedback loss (FbL, FbH)"},{"bit":15,"ko":"시리얼 통신 전송 오류(CALL)","en":"Serial communication transmission error (CALL)"}],"description":{"ko":"bit 6 은 매뉴얼에 «Drive Overheat Warning (ov)» 로 적혀 이름과 약호가 어긋나 뺐다","en":"Bit 6 is printed as 'Drive Overheat Warning (ov)' (name and code disagree), so it is left out"},"ref":"p.718","source":0},{"table":"holding-registers","address":43,"manualAddress":"002BH","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"S1 닫힘","en":"Terminal S1 closed"},{"bit":1,"ko":"S2 닫힘","en":"Terminal S2 closed"},{"bit":2,"ko":"S3 닫힘","en":"Terminal S3 closed"},{"bit":3,"ko":"S4 닫힘","en":"Terminal S4 closed"},{"bit":4,"ko":"S5 닫힘","en":"Terminal S5 closed"},{"bit":5,"ko":"S6 닫힘","en":"Terminal S6 closed"},{"bit":6,"ko":"S7 닫힘","en":"Terminal S7 closed"},{"bit":7,"ko":"S8 닫힘","en":"Terminal S8 closed"}],"ref":"p.719","source":0},{"table":"holding-registers","address":44,"manualAddress":"002CH","type":"u16","name":{"ko":"드라이브 상태 2","en":"Drive status 2"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"영속도","en":"Zero speed"},{"bit":2,"ko":"속도 일치","en":"Speed agree"},{"bit":3,"ko":"사용자 속도 일치","en":"User speed agree"},{"bit":4,"ko":"주파수 검출 1","en":"Frequency detection 1"},{"bit":5,"ko":"주파수 검출 2","en":"Frequency detection 2"},{"bit":6,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":7,"ko":"저전압 중","en":"During undervoltage"},{"bit":8,"ko":"베이스블록 중","en":"During baseblock"},{"bit":9,"ko":"주파수 지령이 오퍼레이터","en":"Frequency reference from operator keypad"},{"bit":10,"ko":"운전 지령이 오퍼레이터","en":"Run command from operator keypad"},{"bit":11,"ko":"과토크/저토크 1·2","en":"Over/undertorque 1, 2"},{"bit":12,"ko":"주파수 지령 상실","en":"Frequency reference loss"},{"bit":13,"ko":"고장 재시작 중","en":"During fault restart"},{"bit":14,"ko":"고장","en":"Fault"},{"bit":15,"ko":"통신 타임아웃","en":"Communication timeout"}],"ref":"p.719","source":0},{"table":"holding-registers","address":45,"manualAddress":"002DH","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"다기능 접점 출력 1(M1-M2)","en":"Multi-function contact output 1 (M1-M2)"},{"bit":1,"ko":"다기능 접점 출력 2(M3-M4)","en":"Multi-function contact output 2 (M3-M4)"},{"bit":2,"ko":"다기능 접점 출력 3(M5-M6)","en":"Multi-function contact output 3 (M5-M6)"},{"bit":7,"ko":"고장 접점 출력(MA/MB-MC)","en":"Fault contact output (MA/MB-MC)"}],"ref":"p.719","source":0},{"table":"holding-registers","address":49,"manualAddress":"0031H","type":"u16","name":{"ko":"DC 버스 전압","en":"DC bus voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.719","source":0},{"table":"holding-registers","address":50,"manualAddress":"0032H","type":"u16","name":{"ko":"토크 지령(U1-09)","en":"Torque reference (U1-09)"},"unit":"%","access":"r","fc":[3],"ref":"p.719","source":0},{"table":"holding-registers","address":56,"manualAddress":"0038H","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"부호 없음, 100% = 최대 출력 주파수","en":"Unsigned, 100% = max. output frequency"},"ref":"p.719","source":0},{"table":"holding-registers","address":57,"manualAddress":"0039H","type":"s16","name":{"ko":"PID 입력","en":"PID input"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"100% = 최대 출력 주파수","en":"100% = max. output frequency"},"ref":"p.719","source":0},{"table":"holding-registers","address":58,"manualAddress":"003AH","type":"s16","name":{"ko":"PID 출력","en":"PID output"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"100% = 최대 출력 주파수","en":"100% = max. output frequency"},"ref":"p.719","source":0},{"table":"holding-registers","address":61,"manualAddress":"003DH","type":"u16","name":{"ko":"통신 오류 내용","en":"Communications error contents"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"CRC 오류","en":"CRC error"},{"bit":1,"ko":"데이터 길이 오류","en":"Data length error"},{"bit":3,"ko":"패리티 오류","en":"Parity error"},{"bit":4,"ko":"오버런 오류","en":"Overrun error"},{"bit":5,"ko":"프레이밍 오류","en":"Framing error"},{"bit":6,"ko":"타임아웃","en":"Timeout"}],"description":{"ko":"고장 리셋까지 유지","en":"Kept until fault reset"},"ref":"p.720","source":0},{"table":"holding-registers","address":75,"manualAddress":"004BH","type":"u16","name":{"ko":"드라이브 상태(U1-12)","en":"Drive status (U1-12)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"영속도 중","en":"During zero speed"},{"bit":2,"ko":"역방향 운전 중","en":"During reverse run"},{"bit":3,"ko":"고장 리셋 신호 입력 중","en":"During fault reset signal input"},{"bit":4,"ko":"속도 일치 중","en":"During speed agree"},{"bit":5,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":6,"ko":"경보","en":"Alarm"},{"bit":7,"ko":"고장","en":"Fault"},{"bit":8,"ko":"설정 오류(oPE) 중","en":"During operation error (oPE)"},{"bit":9,"ko":"순간 정전 중","en":"During momentary power loss"},{"bit":10,"ko":"모터 2 선택","en":"Motor 2 selected"},{"bit":14,"ko":"ComRef·NetRef 상태","en":"ComRef / NetRef status"},{"bit":15,"ko":"ComCtrl·NetCtrl 상태","en":"ComCtrl / NetCtrl status"}],"ref":"p.720","source":0},{"table":"holding-registers","address":127,"manualAddress":"007FH","type":"u16","name":{"ko":"경고(경고 고장) 코드","en":"Minor fault code"},"access":"r","fc":[3],"description":{"ko":"코드 뜻은 p.731 경보 레지스터 표","en":"Code meanings: alarm register table p.731"},"ref":"p.720","source":0},{"table":"holding-registers","address":128,"manualAddress":"0080H","type":"u16","name":{"ko":"현재 고장(U2-01)","en":"Current fault (U2-01)"},"access":"r","fc":[3],"values":[{"value":2,"ko":"Uv1 주회로 저전압","en":"Uv1 undervoltage"},{"value":3,"ko":"Uv2 제어 전원 저전압","en":"Uv2 control power supply undervoltage"},{"value":4,"ko":"Uv3 충전 회로 이상","en":"Uv3 soft charge circuit fault"},{"value":6,"ko":"GF 지락","en":"GF ground fault"},{"value":7,"ko":"oC 과전류","en":"oC overcurrent"},{"value":9,"ko":"oH 방열판 과열","en":"oH heatsink overheat"},{"value":10,"ko":"oH1 방열판 과열","en":"oH1 heatsink overheat"},{"value":11,"ko":"oL1 모터 과부하","en":"oL1 motor overload"},{"value":12,"ko":"oL2 드라이브 과부하","en":"oL2 drive overload"},{"value":13,"ko":"oL3 과토크 검출 1","en":"oL3 overtorque detection 1"},{"value":14,"ko":"oL4 과토크 검출 2","en":"oL4 overtorque detection 2"},{"value":27,"ko":"PF 입력 결상","en":"PF input phase loss"},{"value":28,"ko":"LF 출력 결상","en":"LF output phase loss"},{"value":33,"ko":"CE MEMOBUS/Modbus 통신 오류","en":"CE MEMOBUS/Modbus communication error"}],"description":{"ko":"값은 고장 코드(표 C.6). 일부만 실었고 0008H 는 이름·약호가 어긋나 뺐다","en":"Value is a fault code (Table C.6); only some listed, 0008H left out (name and code disagree)"},"ref":"p.729 표 C.6","source":0},{"table":"holding-registers","address":129,"manualAddress":"0081H","type":"u16","name":{"ko":"직전 고장(U2-02)","en":"Previous fault (U2-02)"},"access":"r","fc":[3],"values":[{"value":2,"ko":"Uv1 주회로 저전압","en":"Uv1 undervoltage"},{"value":3,"ko":"Uv2 제어 전원 저전압","en":"Uv2 control power supply undervoltage"},{"value":4,"ko":"Uv3 충전 회로 이상","en":"Uv3 soft charge circuit fault"},{"value":6,"ko":"GF 지락","en":"GF ground fault"},{"value":7,"ko":"oC 과전류","en":"oC overcurrent"},{"value":9,"ko":"oH 방열판 과열","en":"oH heatsink overheat"},{"value":10,"ko":"oH1 방열판 과열","en":"oH1 heatsink overheat"},{"value":11,"ko":"oL1 모터 과부하","en":"oL1 motor overload"},{"value":12,"ko":"oL2 드라이브 과부하","en":"oL2 drive overload"},{"value":13,"ko":"oL3 과토크 검출 1","en":"oL3 overtorque detection 1"},{"value":14,"ko":"oL4 과토크 검출 2","en":"oL4 overtorque detection 2"},{"value":27,"ko":"PF 입력 결상","en":"PF input phase loss"},{"value":28,"ko":"LF 출력 결상","en":"LF output phase loss"},{"value":33,"ko":"CE MEMOBUS/Modbus 통신 오류","en":"CE MEMOBUS/Modbus communication error"}],"description":{"ko":"값은 고장 코드(표 C.6). 일부만 실었다","en":"Value is a fault code (Table C.6); only some listed"},"ref":"p.729 표 C.6","source":0},{"table":"holding-registers","address":152,"manualAddress":"0098H","type":"u16","name":{"ko":"누적 운전 시간(U4-01) 10 h 단위","en":"Cumulative operation time (U4-01), 10 h units"},"unit":"h","scale":10,"access":"r","fc":[3],"description":{"ko":"12345 h 이면 0098H = 1234, 0099H = 5","en":"For 12345 h: 0098H = 1234, 0099H = 5"},"ref":"p.720","source":0},{"table":"holding-registers","address":153,"manualAddress":"0099H","type":"u16","name":{"ko":"누적 운전 시간(U4-01) 1 h 자리","en":"Cumulative operation time (U4-01), 1 h digit"},"unit":"h","access":"r","fc":[3],"ref":"p.720","source":0},{"table":"holding-registers","address":171,"manualAddress":"00ABH","type":"u16","name":{"ko":"드라이브 정격 전류","en":"Drive rated current"},"unit":"A","access":"r","fc":[3],"description":{"ko":"배율은 0026H 와 같이 형번별 (p.728 주 <2>)","en":"Scale by model as for 0026H (p.728 note <2>)"},"ref":"p.720","source":0},{"table":"holding-registers","address":2304,"manualAddress":"0900H","type":"u16","name":{"ko":"Enter 명령(EEPROM 저장)","en":"Enter command (save to EEPROM)"},"access":"w","fc":[16],"description":{"ko":"0 을 쓴다. 쓰기 전용","en":"Write 0. Write-only"},"ref":"p.732","source":0},{"table":"holding-registers","address":2320,"manualAddress":"0910H","type":"u16","name":{"ko":"Enter 명령(RAM 만)","en":"Enter command (RAM only)"},"access":"w","fc":[16],"description":{"ko":"0 을 쓴다. 전원을 끄면 변경 내용이 사라진다","en":"Write 0. Changes are lost at power-off"},"ref":"p.732","source":0}],"notes":[{"ko":"통신으로 운전·주파수를 주려면 b1-02 = 2, b1-01 = 2. 파라미터를 바꿀 때 H5-11 설정에 따라 Enter 명령이 필요하다.","en":"To run and set frequency by communication set b1-02 = 2 and b1-01 = 2. Depending on H5-11, parameter writes need an Enter command."}],"sources":[{"title":"YASKAWA AC Drive-A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 41H)","publisher":"YASKAWA ELECTRIC CORPORATION","edition":{"ko":"SIEP C710616 41H <7>-0, PDF 2022년 3월","en":"SIEP C710616 41H <7>-0, PDF dated March 2022"},"url":"https://www.yaskawa.com/delegate/getAttachment?documentId=SIEPC71061641&cmd=documents&documentName=SIEPC71061641.pdf","pages":{"ko":"부록 C MEMOBUS/Modbus p.703~732 (데이터 표 p.716~731)","en":"Appendix C MEMOBUS/Modbus pp.703-732 (data table pp.716-731)"},"checked":"2026-10-23"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"yaskawa/j1000","manufacturer":{"ko":"야스카와","en":"YASKAWA"},"model":"J1000","models":["CIMR-JU"],"kind":"inverter","title":{"ko":"야스카와 J1000 인버터 (SI-485/J 옵션 MEMOBUS/Modbus)","en":"YASKAWA J1000 AC drive (MEMOBUS/Modbus via SI-485/J option)"},"summary":{"ko":"SI-485/J 옵션으로 RS-422/485 MEMOBUS/Modbus RTU. 지령 0001H~, 모니터 0020H~, Enter 명령 0900H","en":"RS-422/485 MEMOBUS/Modbus RTU through the SI-485/J option. Commands from 0001H, monitors from 0020H, Enter command 0900H"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":1,"unit":31,"unitRange":[1,255],"maxRegisters":16,"addressing":"zero","notes":[{"ko":"주소 체계: 읽기 예(p.224)는 02 03 00 20 00 04 45 F0 으로 0020H(드라이브 상태 1)부터 4개를 읽고, 쓰기 예(p.225)는 01 10 00 01 00 02 04 00 01 17 70 으로 0001H 에 0001h(정방향 운전)·0002H 에 1770h 를 쓴다(응답 01 10 00 01 00 02 10 08). 매뉴얼 주소 = 프레임 주소. 읽기 명령·쓰기 응답·오류 응답(02 83 03 F1 31, 01 90 02 CD C1)·루프백(01 08 00 00 A5 37 DA 8D)의 CRC 는 계산값과 같다. 읽기 정상 응답의 CRC 는 AF 82 로 적혀 있으나 계산값은 D5 6B, 쓰기 명령의 CRC 는 6D 67 로 적혀 있으나 계산값은 6D B7 — 주소와는 무관","en":"Addressing: the read example (p.224) sends 02 03 00 20 00 04 45 F0 to read 4 registers from 0020H (drive status 1); the write example (p.225) sends 01 10 00 01 00 02 04 00 01 17 70, writing 0001h (forward run) to 0001H and 1770h to 0002H (response 01 10 00 01 00 02 10 08). Manual address = frame address. CRCs of the read command, write response, error responses (02 83 03 F1 31, 01 90 02 CD C1) and loopback (01 08 00 00 A5 37 DA 8D) match calculation. The normal read response CRC is printed AF 82 but computes to D5 6B, and the write command CRC is printed 6D 67 but computes to 6D B7; this does not affect addressing."},{"ko":"함수 코드는 03H(읽기, 한 번에 16개까지)·08H(루프백)·10H(여러 개 쓰기)뿐 — 06H 없음 (p.222, p.224).","en":"Only function codes 03H (read, up to 16 registers), 08H (loopback) and 10H (write multiple) — no 06H (p.222, p.224)."},{"ko":"초기값: H5-01 국번 1F(31), 0~FF(0 이면 응답 없음); H5-02 3 = 9600 bps(0~5 = 1200~38400); H5-03 0 = 패리티 없음(1 짝수·2 홀수); 데이터 8비트·정지 1비트 고정, RTU 만 (p.212, p.217). 변경 후 전원 재투입.","en":"Defaults: H5-01 address 1F (31), range 0-FF (0 = no response); H5-02 3 = 9600 bps (0-5 = 1200-38400); H5-03 0 = no parity (1 even, 2 odd); 8 data bits and 1 stop bit fixed, RTU only (p.212, p.217). Cycle power after changes."},{"ko":"RS-485 로 쓸 때 H5-07 = 1(초기값), 끝단 드라이브는 SI-485/J 의 DIP 스위치 S2 를 ON(종단 저항) (p.214~216).","en":"For RS-485 keep H5-07 = 1 (default); on the last drive set DIP switch S2 on the SI-485/J to ON (termination) (pp.214-216)."}]},"notes":[{"ko":"통신으로 운전·주파수를 주려면 b1-02 = 2, b1-01 = 2 (p.220 표 C.1).","en":"To run and set frequency by communication set b1-02 = 2 and b1-01 = 2 (p.220 Table C.1)."},{"ko":"주파수 지령 0002H·주파수 지령 모니터 0023H·출력 주파수 0024H 는 넣지 않았다 — 표(p.226~227)는 단위를 H5-13 으로 정한다고 하고 H5-13 초기값 0 은 «0.1Hz / 1»(p.219)인데, 같은 매뉴얼의 쓰기 예(p.225)는 1770h(6000)를 60.00 Hz 로 적어 배율이 어긋난다. 같은 H5-13 이 «주파수 모니터 단위» 도 정해 U1-01·U1-02(0040H·0041H, 표 p.203 은 0.01 Hz)도 넣지 않았다. 주파수는 단위가 0.01% 로 고정된 00B8H·003FH 로 읽는다.","en":"Frequency reference 0002H, frequency reference monitor 0023H and output frequency 0024H are not included: the table (pp.226-227) says their unit is set by H5-13, whose default 0 is «0.1Hz / 1» (p.219), but the write example in the same manual (p.225) gives 1770h (6000) as 60.00 Hz, so the scaling disagrees. Because H5-13 also sets the «frequency monitor unit», U1-01/U1-02 (0040H/0041H, 0.01 Hz in the table on p.203) are left out too. Read frequency through 00B8H and 003FH, whose unit is fixed at 0.01%."},{"ko":"출력 전류 0026H·드라이브 정격 전류 00ABH 는 표(p.227, p.229)에 단위가 없어 넣지 않았다(전류는 0042H, 8192 = 정격 100%). U4-01 의 004CH 도 넣지 않았다 — 모니터 표(p.204)는 1 h 단위, 각주 <3>(p.205)은 통신 값이 10 h 단위라고 해 어긋나므로 0098H·0099H 로 읽는다.","en":"Output current 0026H and drive rated current 00ABH have no unit in the table (p.227, p.229) and are left out (use 0042H, 8192 = 100% rated). U4-01 at 004CH is also left out: the monitor table (p.204) says 1 h units while footnote <3> (p.205) says the communication value is in 10 h units, so read 0098H/0099H instead."},{"ko":"통신으로 바꾼 파라미터는 RAM 에만 반영되므로 남기려면 0900H 에 0 을 쓴다(p.233). 파라미터 주소는 부록 B 표의 Addr. Hex 칸.","en":"Parameters changed by communication are applied to RAM only; write 0 to 0900H to keep them (p.233). Parameter addresses are in the Addr. Hex column of the Appendix B tables."}],"registers":[{"table":"holding-registers","address":1,"manualAddress":"0001H","type":"u16","name":{"ko":"운전 신호·다기능 입력","en":"Operation signals and multi-function inputs"},"access":"rw","fc":[3,16],"bits":[{"bit":0,"ko":"정방향 운전(H5-12=0) / 운전(H5-12=1)","en":"Forward run (H5-12=0) / Run (H5-12=1)"},{"bit":1,"ko":"역방향 운전(H5-12=0) / 정·역 선택 1=역(H5-12=1)","en":"Reverse run (H5-12=0) / FWD-REV, 1 = reverse (H5-12=1)"},{"bit":2,"ko":"외부 고장(EF0)","en":"External fault (EF0)"},{"bit":3,"ko":"고장 리셋","en":"Fault reset"},{"bit":4,"ko":"다기능 입력 1","en":"Multi-function input 1"},{"bit":5,"ko":"다기능 입력 2","en":"Multi-function input 2"},{"bit":6,"ko":"다기능 입력 3","en":"Multi-function input 3"},{"bit":7,"ko":"다기능 입력 4","en":"Multi-function input 4"},{"bit":8,"ko":"다기능 입력 5","en":"Multi-function input 5"}],"description":{"ko":"H5-12 초기값 0(정방향/정지, 역방향/정지). 운전 지령 소스 b1-02 = 2(MEMOBUS) 일 때 운전","en":"H5-12 default 0 (FWD/stop, REV/stop). Runs when run command source b1-02 = 2 (MEMOBUS)"},"ref":"p.226","source":0},{"table":"holding-registers","address":7,"manualAddress":"0007H","type":"u16","name":{"ko":"아날로그 출력 AM 설정","en":"Analog output terminal AM setting"},"unit":"V","scale":0.0006103515625,"access":"rw","fc":[3,16],"description":{"ko":"10 V = 4000H(16384)","en":"10 V = 4000H (16384)"},"ref":"p.226","source":0},{"table":"holding-registers","address":9,"manualAddress":"0009H","type":"u16","name":{"ko":"다기능 디지털 출력 설정","en":"Multi-function digital output settings"},"access":"rw","fc":[3,16],"bits":[{"bit":0,"ko":"접점 출력(MA-MB-MC)","en":"Contact output (MA-MB-MC)"}],"ref":"p.226","source":0},{"table":"holding-registers","address":15,"manualAddress":"000FH","type":"u16","name":{"ko":"제어 선택 설정","en":"Control selection setting"},"access":"rw","fc":[3,16],"bits":[{"bit":12,"ko":"단자 S5 입력 유효","en":"Terminal S5 input enabled"}],"ref":"p.226","source":0},{"table":"holding-registers","address":32,"manualAddress":"0020H","type":"u16","name":{"ko":"드라이브 상태 1","en":"Drive status 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"역방향 운전 중","en":"During reverse"},{"bit":2,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":3,"ko":"고장","en":"Fault"},{"bit":4,"ko":"데이터 설정 오류","en":"Data setting error"},{"bit":5,"ko":"다기능 접점 출력(MA/MB-MC)","en":"Multi-function contact output (MA/MB-MC)"},{"bit":14,"ko":"ComRef 유효","en":"ComRef enabled"},{"bit":15,"ko":"ComCtrl 유효","en":"ComCtrl enabled"}],"ref":"p.227","source":0},{"table":"holding-registers","address":33,"manualAddress":"0021H","type":"u16","name":{"ko":"고장 내용 1","en":"Fault contents 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"과전류(oC)","en":"Overcurrent (oC)"},{"bit":1,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"bit":2,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"bit":3,"ko":"과열 1(oH1)","en":"Overheat 1 (oH1)"},{"bit":4,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"},{"bit":7,"ko":"외부 고장 EF0~5","en":"External fault EF0-5"},{"bit":8,"ko":"하드웨어 고장 CPF(oFx 포함)","en":"Hardware fault CPF (includes oFx)"},{"bit":9,"ko":"모터 과부하(oL1)·과토크 검출 1(oL3)","en":"Motor overload (oL1), overtorque detection 1 (oL3)"},{"bit":11,"ko":"주회로 저전압(Uv)","en":"Main circuit undervoltage (Uv)"},{"bit":12,"ko":"저전압(Uv1)·충전 회로 고장(Uv3)","en":"Undervoltage (Uv1), soft charge circuit fault (Uv3)"},{"bit":13,"ko":"출력 결상(LF)·입력 결상(PF)","en":"Output phase loss (LF), input phase loss (PF)"},{"bit":14,"ko":"MEMOBUS/Modbus 통신 오류(CE)","en":"MEMOBUS/Modbus communication error (CE)"},{"bit":15,"ko":"오퍼레이터 연결 고장(oPr)","en":"Operator connection fault (oPr)"}],"ref":"p.227","source":0},{"table":"holding-registers","address":34,"manualAddress":"0022H","type":"u16","name":{"ko":"데이터 링크 상태","en":"Data link status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"데이터 쓰는 중·모터 전환 중","en":"Writing data or switching motors"},{"bit":3,"ko":"상·하한 오류","en":"Upper or lower limit error"},{"bit":4,"ko":"데이터 정합 오류","en":"Data conformity error"},{"bit":5,"ko":"EEPROM 쓰는 중","en":"Writing to EEPROM"}],"ref":"p.227","source":0},{"table":"holding-registers","address":37,"manualAddress":"0025H","type":"u16","name":{"ko":"출력 전압 지령","en":"Output voltage reference"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.227","source":0},{"table":"holding-registers","address":41,"manualAddress":"0029H","type":"u16","name":{"ko":"고장 내용 2","en":"Fault contents 2"},"access":"r","fc":[3],"bits":[{"bit":2,"ko":"입력 결상(PF)","en":"Input phase loss (PF)"},{"bit":3,"ko":"출력 결상(LF)","en":"Output phase loss (LF)"},{"bit":4,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"}],"ref":"p.227","source":0},{"table":"holding-registers","address":42,"manualAddress":"002AH","type":"u16","name":{"ko":"경보 내용 1","en":"Alarm contents 1"},"access":"r","fc":[3],"bits":[{"bit":2,"ko":"운전 지령 입력 오류(EF)","en":"Run command input error (EF)"},{"bit":3,"ko":"베이스 블록(bb)","en":"Drive baseblock (bb)"},{"bit":4,"ko":"과토크 검출 1(oL3)","en":"Overtorque detection 1 (oL3)"},{"bit":5,"ko":"방열판 과열(oH)","en":"Heatsink overheat (oH)"},{"bit":6,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"bit":7,"ko":"저전압(Uv)","en":"Undervoltage (Uv)"},{"bit":9,"ko":"MEMOBUS/Modbus 통신 오류(CE)","en":"MEMOBUS/Modbus communication error (CE)"}],"ref":"p.228","source":0},{"table":"holding-registers","address":43,"manualAddress":"002BH","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"S1 닫힘","en":"Terminal S1 closed"},{"bit":1,"ko":"S2 닫힘","en":"Terminal S2 closed"},{"bit":2,"ko":"S3 닫힘","en":"Terminal S3 closed"},{"bit":3,"ko":"S4 닫힘","en":"Terminal S4 closed"},{"bit":4,"ko":"S5 닫힘","en":"Terminal S5 closed"}],"ref":"p.228","source":0},{"table":"holding-registers","address":44,"manualAddress":"002CH","type":"u16","name":{"ko":"드라이브 상태 2","en":"Drive status 2"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"영속도","en":"Zero speed"},{"bit":2,"ko":"속도 일치","en":"Speed agree"},{"bit":3,"ko":"사용자 속도 일치","en":"User speed agree"},{"bit":4,"ko":"주파수 검출 1","en":"Frequency detection 1"},{"bit":5,"ko":"주파수 검출 2","en":"Frequency detection 2"},{"bit":6,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":7,"ko":"저전압 중","en":"During undervoltage"},{"bit":8,"ko":"베이스 블록 중","en":"During baseblock"},{"bit":9,"ko":"주파수 지령이 오퍼레이터","en":"Frequency reference from operator keypad"},{"bit":10,"ko":"운전 지령이 오퍼레이터","en":"Run command from operator keypad"},{"bit":11,"ko":"과토크","en":"Overtorque"},{"bit":14,"ko":"고장","en":"Fault"},{"bit":15,"ko":"통신 타임아웃","en":"Communication timeout"}],"ref":"p.228","source":0},{"table":"holding-registers","address":45,"manualAddress":"002DH","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"다기능 접점 출력(MA/MB-MC)","en":"Multi-function contact output (MA/MB-MC)"}],"ref":"p.228","source":0},{"table":"holding-registers","address":49,"manualAddress":"0031H","type":"u16","name":{"ko":"DC 버스 전압","en":"DC bus voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.228","source":0},{"table":"holding-registers","address":52,"manualAddress":"0034H","type":"string","len":2,"name":{"ko":"제품 코드 1(ASCII)","en":"Product code 1 (ASCII)"},"access":"r","fc":[3],"description":{"ko":"J1000 은 «J0»","en":"«J0» for J1000"},"ref":"p.228","source":0},{"table":"holding-registers","address":61,"manualAddress":"003DH","type":"u16","name":{"ko":"통신 오류 기록","en":"Communications error log"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"CRC 오류","en":"CRC error"},{"bit":1,"ko":"데이터 길이 오류","en":"Data length error"},{"bit":3,"ko":"패리티 오류","en":"Parity error"},{"bit":4,"ko":"오버런 오류","en":"Overrun error"},{"bit":5,"ko":"프레이밍 오류","en":"Framing error"},{"bit":6,"ko":"타임아웃","en":"Timeout"}],"description":{"ko":"고장을 리셋할 때까지 남는다","en":"Kept until the fault is reset"},"ref":"p.229","source":0},{"table":"holding-registers","address":63,"manualAddress":"003FH","type":"u16","name":{"ko":"출력 주파수(%)","en":"Output frequency (%)"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.229","source":0},{"table":"holding-registers","address":66,"manualAddress":"0042H","type":"u16","name":{"ko":"출력 전류(U1-03)","en":"Output current (U1-03)"},"access":"r","fc":[3],"description":{"ko":"통신으로 읽으면 8192 = 드라이브 정격 출력 전류의 100%","en":"Via MEMOBUS/Modbus, 8192 = 100% of drive rated output current"},"ref":"p.203, p.205","source":0},{"table":"holding-registers","address":69,"manualAddress":"0045H","type":"u16","name":{"ko":"출력 전압(U1-06)","en":"Output voltage (U1-06)"},"unit":"V","scale":0.1,"access":"r","fc":[3],"ref":"p.203","source":0},{"table":"holding-registers","address":70,"manualAddress":"0046H","type":"u16","name":{"ko":"DC 버스 전압(U1-07)","en":"DC bus voltage (U1-07)"},"unit":"V","access":"r","fc":[3],"ref":"p.203","source":0},{"table":"holding-registers","address":78,"manualAddress":"004EH","type":"u16","name":{"ko":"아날로그 입력 A1 레벨(U1-13)","en":"Terminal A1 input level (U1-13)"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"10 V 또는 20 mA 입력이 100%","en":"100% at 10 V or 20 mA input"},"ref":"p.204","source":0},{"table":"holding-registers","address":124,"manualAddress":"007CH","type":"u16","name":{"ko":"주회로 콘덴서 수명(U4-05)","en":"Capacitor maintenance (U4-05)"},"unit":"%","access":"r","fc":[3],"description":{"ko":"100% 가 되면 교체 시기","en":"Replacement due at 100%"},"ref":"p.204","source":0},{"table":"holding-registers","address":126,"manualAddress":"007EH","type":"u16","name":{"ko":"냉각팬 수명(U4-04)","en":"Cooling fan maintenance (U4-04)"},"unit":"%","access":"r","fc":[3],"description":{"ko":"100% 가 되면 교체 시기","en":"Replacement due at 100%"},"ref":"p.204","source":0},{"table":"holding-registers","address":127,"manualAddress":"007FH","type":"u16","name":{"ko":"경보 코드","en":"Alarm code"},"access":"r","fc":[3],"values":[{"value":1,"ko":"저전압(Uv)","en":"Undervoltage (Uv)"},{"value":2,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"value":3,"ko":"방열판 과열(oH)","en":"Heatsink overheat (oH)"},{"value":5,"ko":"과토크 1(oL3)","en":"Overtorque 1 (oL3)"},{"value":7,"ko":"운전 지령 입력 오류(EF)","en":"Run commands input error (EF)"},{"value":8,"ko":"베이스 블록(bb)","en":"Drive baseblock (bb)"},{"value":9,"ko":"외부 고장 3, 단자 S3(EF3)","en":"External fault 3, terminal S3 (EF3)"},{"value":10,"ko":"외부 고장 4, 단자 S4(EF4)","en":"External fault 4, terminal S4 (EF4)"},{"value":11,"ko":"외부 고장 5, 단자 S5(EF5)","en":"External fault 5, terminal S5 (EF5)"},{"value":20,"ko":"MEMOBUS/Modbus 통신 오류(CE)","en":"MEMOBUS/Modbus communication error (CE)"},{"value":23,"ko":"모터 과부하(oL1)","en":"Motor overload (oL1)"},{"value":24,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"value":32,"ko":"MEMOBUS/Modbus 시험 모드 고장(SE)","en":"MEMOBUS/Modbus test mode fault (SE)"},{"value":57,"ko":"외부 고장, 단자 S1(EF1)","en":"External fault, terminal S1 (EF1)"},{"value":58,"ko":"외부 고장, 단자 S2(EF2)","en":"External fault, terminal S2 (EF2)"}],"description":{"ko":"표 C.5 의 코드 전부","en":"All codes from Table C.5"},"ref":"p.229, p.232 표 C.5","source":0},{"table":"holding-registers","address":128,"manualAddress":"0080H","type":"u16","name":{"ko":"현재 고장(U2-01)","en":"Current fault (U2-01)"},"access":"r","fc":[3],"values":[{"value":2,"ko":"저전압(Uv1)","en":"Undervoltage (Uv1)"},{"value":4,"ko":"충전 회로 고장(Uv3)","en":"Soft charge circuit fault (Uv3)"},{"value":7,"ko":"과전류(oC)","en":"Overcurrent (oC)"},{"value":8,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"value":10,"ko":"방열판 과열(oH1)","en":"Heatsink overheat (oH1)"},{"value":11,"ko":"모터 과부하(oL1)","en":"Motor overload (oL1)"},{"value":12,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"value":13,"ko":"과토크 검출 1(oL3)","en":"Overtorque detection 1 (oL3)"},{"value":16,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"},{"value":17,"ko":"외부 고장, 단자 S3(EF3)","en":"External fault, terminal S3 (EF3)"},{"value":18,"ko":"외부 고장, 단자 S4(EF4)","en":"External fault, terminal S4 (EF4)"},{"value":19,"ko":"외부 고장, 단자 S5(EF5)","en":"External fault, terminal S5 (EF5)"},{"value":27,"ko":"입력 결상(PF)","en":"Input phase loss (PF)"},{"value":28,"ko":"출력 결상(LF)","en":"Output phase loss (LF)"},{"value":30,"ko":"디지털 오퍼레이터 연결(oPr)","en":"Digital operator connection (oPr)"},{"value":31,"ko":"EEPROM 쓰기 오류(Err)","en":"EEPROM write error (Err)"},{"value":33,"ko":"MEMOBUS/Modbus 통신 오류(CE)","en":"MEMOBUS/Modbus communication error (CE)"},{"value":39,"ko":"PROFIBUS-DP 옵션 외부 고장(EF0)","en":"PROFIBUS-DP option external fault (EF0)"},{"value":66,"ko":"외부 고장 1, 단자 S1(EF1)","en":"External fault 1, terminal S1 (EF1)"},{"value":67,"ko":"외부 고장 2, 단자 S2(EF2)","en":"External fault 2, terminal S2 (EF2)"},{"value":70,"ko":"전류 오프셋 고장(CoF)","en":"Current offset fault (CoF)"},{"value":131,"ko":"A/D 변환 오류(CPF02)","en":"A/D conversion error (CPF02)"},{"value":135,"ko":"단자대·제어 보드 교체 시 사양 불일치(CPF06)","en":"Drive specification mismatch after terminal/control board replacement (CPF06)"},{"value":137,"ko":"EEPROM 직렬 통신 고장(CPF08)","en":"EEPROM serial communication fault (CPF08)"},{"value":140,"ko":"RAM 고장(CPF11)","en":"RAM fault (CPF11)"},{"value":141,"ko":"플래시 메모리 이상(CPF12)","en":"Flash memory circuit exception (CPF12)"},{"value":143,"ko":"제어 회로 고장(CPF14)","en":"Control circuit fault (CPF14)"},{"value":146,"ko":"타이밍 고장(CPF17)","en":"Timing fault (CPF17)"},{"value":147,"ko":"제어 회로 고장(CPF18)","en":"Control circuit fault (CPF18)"},{"value":149,"ko":"전원 투입 시 하드웨어 고장(CPF20)","en":"Hardware fault at power up (CPF20)"},{"value":150,"ko":"통신 시작 시 하드웨어 고장(CPF21)","en":"Hardware fault at communication start up (CPF21)"},{"value":151,"ko":"A/D 변환 고장(CPF22)","en":"A/D conversion fault (CPF22)"},{"value":152,"ko":"PWM 피드백 고장(CPF23)","en":"PWM feedback fault (CPF23)"},{"value":153,"ko":"드라이브 용량 신호 고장(CPF24)","en":"Drive capacity signal fault (CPF24)"},{"value":257,"ko":"옵션 호환 오류(oFA00)","en":"Option compatibility error (oFA00)"}],"description":{"ko":"값은 고장 코드(표 C.4 전부). Uv1 은 이력에 남지 않는다","en":"Value is a fault code (all of Table C.4). Uv1 is not saved to the history"},"ref":"p.204, p.232 표 C.4","source":0},{"table":"holding-registers","address":129,"manualAddress":"0081H","type":"u16","name":{"ko":"직전 고장(U2-02)","en":"Previous fault (U2-02)"},"access":"r","fc":[3],"values":[{"value":2,"ko":"저전압(Uv1)","en":"Undervoltage (Uv1)"},{"value":4,"ko":"충전 회로 고장(Uv3)","en":"Soft charge circuit fault (Uv3)"},{"value":7,"ko":"과전류(oC)","en":"Overcurrent (oC)"},{"value":8,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"value":10,"ko":"방열판 과열(oH1)","en":"Heatsink overheat (oH1)"},{"value":11,"ko":"모터 과부하(oL1)","en":"Motor overload (oL1)"},{"value":12,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"value":13,"ko":"과토크 검출 1(oL3)","en":"Overtorque detection 1 (oL3)"},{"value":16,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"},{"value":17,"ko":"외부 고장, 단자 S3(EF3)","en":"External fault, terminal S3 (EF3)"},{"value":18,"ko":"외부 고장, 단자 S4(EF4)","en":"External fault, terminal S4 (EF4)"},{"value":19,"ko":"외부 고장, 단자 S5(EF5)","en":"External fault, terminal S5 (EF5)"},{"value":27,"ko":"입력 결상(PF)","en":"Input phase loss (PF)"},{"value":28,"ko":"출력 결상(LF)","en":"Output phase loss (LF)"},{"value":30,"ko":"디지털 오퍼레이터 연결(oPr)","en":"Digital operator connection (oPr)"},{"value":31,"ko":"EEPROM 쓰기 오류(Err)","en":"EEPROM write error (Err)"},{"value":33,"ko":"MEMOBUS/Modbus 통신 오류(CE)","en":"MEMOBUS/Modbus communication error (CE)"},{"value":39,"ko":"PROFIBUS-DP 옵션 외부 고장(EF0)","en":"PROFIBUS-DP option external fault (EF0)"},{"value":66,"ko":"외부 고장 1, 단자 S1(EF1)","en":"External fault 1, terminal S1 (EF1)"},{"value":67,"ko":"외부 고장 2, 단자 S2(EF2)","en":"External fault 2, terminal S2 (EF2)"},{"value":70,"ko":"전류 오프셋 고장(CoF)","en":"Current offset fault (CoF)"},{"value":131,"ko":"A/D 변환 오류(CPF02)","en":"A/D conversion error (CPF02)"},{"value":135,"ko":"단자대·제어 보드 교체 시 사양 불일치(CPF06)","en":"Drive specification mismatch after terminal/control board replacement (CPF06)"},{"value":137,"ko":"EEPROM 직렬 통신 고장(CPF08)","en":"EEPROM serial communication fault (CPF08)"},{"value":140,"ko":"RAM 고장(CPF11)","en":"RAM fault (CPF11)"},{"value":141,"ko":"플래시 메모리 이상(CPF12)","en":"Flash memory circuit exception (CPF12)"},{"value":143,"ko":"제어 회로 고장(CPF14)","en":"Control circuit fault (CPF14)"},{"value":146,"ko":"타이밍 고장(CPF17)","en":"Timing fault (CPF17)"},{"value":147,"ko":"제어 회로 고장(CPF18)","en":"Control circuit fault (CPF18)"},{"value":149,"ko":"전원 투입 시 하드웨어 고장(CPF20)","en":"Hardware fault at power up (CPF20)"},{"value":150,"ko":"통신 시작 시 하드웨어 고장(CPF21)","en":"Hardware fault at communication start up (CPF21)"},{"value":151,"ko":"A/D 변환 고장(CPF22)","en":"A/D conversion fault (CPF22)"},{"value":152,"ko":"PWM 피드백 고장(CPF23)","en":"PWM feedback fault (CPF23)"},{"value":153,"ko":"드라이브 용량 신호 고장(CPF24)","en":"Drive capacity signal fault (CPF24)"},{"value":257,"ko":"옵션 호환 오류(oFA00)","en":"Option compatibility error (oFA00)"}],"description":{"ko":"값은 고장 코드(표 C.4 전부). Uv1 은 이력에 남지 않는다","en":"Value is a fault code (all of Table C.4). Uv1 is not saved to the history"},"ref":"p.204, p.232 표 C.4","source":0},{"table":"holding-registers","address":152,"manualAddress":"0098H","type":"u16","name":{"ko":"누적 운전 시간(U4-01) 10 h 단위","en":"Cumulative operation time (U4-01), 10 h units"},"unit":"h","scale":10,"access":"r","fc":[3],"description":{"ko":"12345 h 이면 0098H = 1234, 0099H = 5","en":"For 12345 h: 0098H = 1234, 0099H = 5"},"ref":"p.229","source":0},{"table":"holding-registers","address":153,"manualAddress":"0099H","type":"u16","name":{"ko":"누적 운전 시간(U4-01) 1 h 자리","en":"Cumulative operation time (U4-01), 1 h digit"},"unit":"h","access":"r","fc":[3],"ref":"p.229","source":0},{"table":"holding-registers","address":182,"manualAddress":"00B6H","type":"u16","name":{"ko":"소프트 스타터 뒤 주파수 지령(%)","en":"Frequency reference after soft-starter (%)"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.229","source":0},{"table":"holding-registers","address":184,"manualAddress":"00B8H","type":"u16","name":{"ko":"주파수 지령(%)","en":"Frequency reference (%)"},"unit":"%","scale":0.01,"access":"r","fc":[3],"ref":"p.229","source":0},{"table":"holding-registers","address":191,"manualAddress":"00BFH","type":"u16","name":{"ko":"oPE 오류 번호","en":"oPE error number"},"access":"r","fc":[3],"ref":"p.229","source":0},{"table":"holding-registers","address":192,"manualAddress":"00C0H","type":"u16","name":{"ko":"고장 내용 1(상세)","en":"Fault contents 1 (detail)"},"access":"r","fc":[3],"bits":[{"bit":1,"ko":"저전압(Uv1)","en":"Undervoltage (Uv1)"},{"bit":3,"ko":"충전 회로 고장(Uv3)","en":"Soft charge circuit fault (Uv3)"},{"bit":6,"ko":"과전류(oC)","en":"Overcurrent (oC)"},{"bit":7,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"bit":9,"ko":"방열판 과열(oH1)","en":"Heatsink overheat (oH1)"},{"bit":10,"ko":"모터 과부하(oL1)","en":"Motor overload (oL1)"},{"bit":11,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"bit":12,"ko":"과토크 검출 1(oL3)","en":"Overtorque detection 1 (oL3)"},{"bit":15,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"}],"ref":"p.229","source":0},{"table":"holding-registers","address":193,"manualAddress":"00C1H","type":"u16","name":{"ko":"고장 내용 2(상세)","en":"Fault contents 2 (detail)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"외부 고장, 단자 S3(EF3)","en":"External fault, terminal S3 (EF3)"},{"bit":1,"ko":"외부 고장, 단자 S4(EF4)","en":"External fault, terminal S4 (EF4)"},{"bit":2,"ko":"외부 고장, 단자 S5(EF5)","en":"External fault, terminal S5 (EF5)"},{"bit":10,"ko":"입력 결상(PF)","en":"Input phase loss (PF)"},{"bit":13,"ko":"디지털 오퍼레이터 연결 고장(oPr)","en":"Digital operator connection fault (oPr)"},{"bit":14,"ko":"EEPROM 쓰기 오류(Err)","en":"EEPROM write error (Err)"}],"ref":"p.229","source":0},{"table":"holding-registers","address":2304,"manualAddress":"0900H","type":"u16","name":{"ko":"Enter 명령(EEPROM 저장)","en":"Enter command (save to EEPROM)"},"access":"w","fc":[16],"description":{"ko":"0 을 쓴다. 읽으면 오류(02H). EEPROM 쓰기 횟수 10만 회 제한. 쓰지 않으면 통신으로 바꾼 파라미터는 RAM 에만 있어 전원을 끄면 사라진다","en":"Write 0. Reading returns error 02H. EEPROM limited to 100,000 writes. Without it, parameters changed by communication stay in RAM only and are lost at power off"},"ref":"p.233 표 C.6","source":0}],"sources":[{"title":"YASKAWA AC Drive-J1000 Compact V/f Control Drive Technical Manual (SIEP C710606 31D)","publisher":"YASKAWA ELECTRIC CORPORATION","edition":{"ko":"SIEP C710606 31D <3>, 2015년 5월 발행","en":"SIEP C710606 31D <3>, published May 2015"},"url":"https://www.yaskawa.com/delegate/getAttachment?documentId=SIEPC71060631&cmd=documents&documentName=SIEPC71060631.pdf","pages":{"ko":"부록 C MEMOBUS/Modbus p.210~235, U 모니터 표 p.203~205","en":"Appendix C MEMOBUS/Modbus pp.210-235, U monitor table pp.203-205"},"checked":"2026-10-24"}]},{"$schema":"../schema.json","schemaVersion":1,"id":"yaskawa/v1000","manufacturer":{"ko":"야스카와","en":"YASKAWA"},"model":"V1000","models":["CIMR-VU"],"kind":"inverter","title":{"ko":"야스카와 V1000 인버터 (내장 MEMOBUS/Modbus)","en":"YASKAWA V1000 AC drive (built-in MEMOBUS/Modbus)"},"summary":{"ko":"내장 RS-422/485 MEMOBUS/Modbus RTU. 지령 0001H~, 모니터 0020H~, Enter 명령 0900H·0910H","en":"Built-in RS-422/485 MEMOBUS/Modbus RTU. Commands from 0001H, monitors from 0020H, Enter commands 0900H/0910H"},"protocols":["rtu"],"comm":{"baud":9600,"bauds":[1200,2400,4800,9600,19200,38400],"dataBits":8,"parity":"none","stopBits":1,"unit":31,"unitRange":[1,32],"maxRegisters":16,"addressing":"zero","notes":[{"ko":"주소 체계: 읽기 예(p.446)는 국번 02, FC03, 시작 00 20, 개수 00 04, CRC 45 F0 으로 0020H(드라이브 상태 1)부터 읽고, 쓰기 예(p.447)는 FC10 시작 00 01, 2개로 0001H 에 0001h(정방향 운전)·0002H 에 1770h(60.00 Hz)를 쓴다. 매뉴얼 주소 = 프레임 주소. (쓰기 예의 CRC 는 매뉴얼에 6D 67 로 적혀 있으나 계산값은 6D B7 — 주소와는 무관)","en":"Addressing: the read example (p.446) sends slave 02, FC03, start 00 20, count 00 04, CRC 45 F0 to read from 0020H (drive status 1); the write example (p.447) sends FC10 start 00 01, 2 registers, writing 0001h (forward run) to 0001H and 1770h (60.00 Hz) to 0002H. Manual address = frame address. (The write example's CRC is printed as 6D 67 but computes to 6D B7; this does not affect addressing.)"},{"ko":"함수 코드는 03H(읽기, 한 번에 16개까지)·08H(루프백)·10H(여러 개 쓰기)뿐 — 06H 없음 (p.444, p.446).","en":"Only function codes 03H (read, up to 16 registers), 08H (loopback) and 10H (write multiple) — no 06H (p.444, p.446)."},{"ko":"초기값: H5-01 국번 1F(31), 0~20H(0 이면 응답 없음); H5-02 3 = 9600 bps; H5-03 0 = 패리티 없음; 데이터 8비트·정지 1비트 고정, RTU 만 (p.434, p.439). 변경 후 전원 재투입.","en":"Defaults: H5-01 address 1F (31), range 0-20H (0 = no response); H5-02 3 = 9600 bps; H5-03 0 = no parity; 8 data bits and 1 stop bit fixed, RTU only (p.434, p.439). Cycle power after changes."},{"ko":"속도: 사양표(p.434)와 H5-02 설정표(p.439)는 57.6·76.8·115.2 kbps 까지 적지만 H5-02 설정 범위 칸은 0~5(38400 bps)로 적혀 있어 38400 bps 까지만 넣었다.","en":"Speeds: the spec table (p.434) and H5-02 list (p.439) go up to 57.6/76.8/115.2 kbps, but the H5-02 setting range reads 0-5 (38400 bps), so bauds stop at 38400."},{"ko":"파라미터를 통신으로 바꿀 때 H5-11 = 0 이면 Enter 명령(0900H/0910H)이 필요, 초기값 1 은 즉시 반영 (p.441).","en":"When writing parameters, H5-11 = 0 requires an Enter command (0900H/0910H); the default 1 applies changes immediately (p.441)."}]},"registers":[{"table":"holding-registers","address":1,"manualAddress":"0001H","type":"u16","name":{"ko":"운전 신호·다기능 입력","en":"Operation signals and multi-function inputs"},"access":"rw","fc":[3,16],"bits":[{"bit":0,"ko":"정방향 운전(H5-12=0) / 운전(H5-12=1)","en":"Forward run (H5-12=0) / Run (H5-12=1)"},{"bit":1,"ko":"역방향 운전(H5-12=0) / 정·역 선택 1=역(H5-12=1)","en":"Reverse run (H5-12=0) / FWD-REV, 1 = reverse (H5-12=1)"},{"bit":2,"ko":"외부 고장(EF0)","en":"External fault (EF0)"},{"bit":3,"ko":"고장 리셋","en":"Fault reset"},{"bit":4,"ko":"다기능 입력 1","en":"Multi-function input 1"},{"bit":5,"ko":"다기능 입력 2","en":"Multi-function input 2"},{"bit":6,"ko":"다기능 입력 3","en":"Multi-function input 3"},{"bit":7,"ko":"다기능 입력 4","en":"Multi-function input 4"},{"bit":8,"ko":"다기능 입력 5","en":"Multi-function input 5"},{"bit":9,"ko":"다기능 입력 6","en":"Multi-function input 6"},{"bit":10,"ko":"다기능 입력 7","en":"Multi-function input 7"}],"description":{"ko":"H5-12 초기값 0(정방향/정지, 역방향/정지). 운전 지령 소스 b1-02 = 2(MEMOBUS) 일 때 운전","en":"H5-12 default 0 (FWD/stop, REV/stop). Runs when run command source b1-02 = 2 (MEMOBUS)"},"ref":"p.448","source":0},{"table":"holding-registers","address":2,"manualAddress":"0002H","type":"u16","name":{"ko":"주파수 지령","en":"Frequency reference"},"unit":"Hz","scale":0.01,"access":"rw","fc":[3,16],"description":{"ko":"단위는 o1-03(초기값 0 = 0.01 Hz). 주파수 지령 소스 b1-01 = 2 필요. 매뉴얼 FC10 예: 60.00 Hz = 1770h (p.447)","en":"Unit set by o1-03 (default 0 = 0.01 Hz). Needs frequency source b1-01 = 2. Manual FC10 example: 60.00 Hz = 1770h (p.447)"},"ref":"p.448","source":0},{"table":"holding-registers","address":3,"manualAddress":"0003H","type":"u16","name":{"ko":"출력 전압 이득","en":"Output voltage gain"},"unit":"%","scale":0.1,"access":"rw","fc":[3,16],"range":{"min":2,"max":200},"description":{"ko":"전원 투입 시 1000(100.0%)","en":"1000 (100.0%) at power-up"},"ref":"p.448","source":0},{"table":"holding-registers","address":6,"manualAddress":"0006H","type":"s16","name":{"ko":"PID 목표값","en":"PID target"},"unit":"%","scale":0.01,"access":"rw","fc":[3,16],"ref":"p.448","source":0},{"table":"holding-registers","address":9,"manualAddress":"0009H","type":"u16","name":{"ko":"다기능 디지털 출력 설정","en":"Multi-function digital output settings"},"access":"rw","fc":[3,16],"bits":[{"bit":0,"ko":"접점 출력(MA/MB-MC)","en":"Contact output (MA/MB-MC)"},{"bit":1,"ko":"포토커플러 출력 1(P1-PC)","en":"Photocoupler output 1 (P1-PC)"},{"bit":2,"ko":"포토커플러 출력 2(P2-PC)","en":"Photocoupler output 2 (P2-PC)"}],"ref":"p.448","source":0},{"table":"holding-registers","address":32,"manualAddress":"0020H","type":"u16","name":{"ko":"드라이브 상태 1","en":"Drive status 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"역방향 운전 중","en":"During reverse"},{"bit":2,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":3,"ko":"고장","en":"Fault"},{"bit":4,"ko":"데이터 설정 오류","en":"Data setting error"},{"bit":5,"ko":"다기능 접점 출력(MA/MB-MC)","en":"Multi-function contact output (MA/MB-MC)"},{"bit":6,"ko":"다기능 포토커플러 출력 1(P1-PC)","en":"Multi-function photocoupler output 1 (P1-PC)"},{"bit":7,"ko":"다기능 포토커플러 출력 2(P2-PC)","en":"Multi-function photocoupler output 2 (P2-PC)"},{"bit":14,"ko":"ComRef 유효","en":"ComRef enabled"},{"bit":15,"ko":"ComCtrl 유효","en":"ComCtrl enabled"}],"ref":"p.449","source":0},{"table":"holding-registers","address":33,"manualAddress":"0021H","type":"u16","name":{"ko":"고장 내용 1","en":"Fault contents 1"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"과전류(oC)·지락(GF)·IGBT 단락(SC)","en":"Overcurrent (oC), ground fault (GF), IGBT short circuit (SC)"},{"bit":1,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"bit":2,"ko":"드라이브 과부하(oL2)","en":"Drive overload (oL2)"},{"bit":3,"ko":"과열 1(oH1)·과열 경고(oH2)","en":"Overheat 1 (oH1), drive overheat warning (oH2)"},{"bit":4,"ko":"제동 트랜지스터 고장(rr)·제동 저항 과열(rH)","en":"Braking transistor fault (rr), braking resistor overheat (rH)"},{"bit":6,"ko":"PID 피드백 상실(FbL/FbH)","en":"PID feedback loss (FbL/FbH)"},{"bit":7,"ko":"외부 고장 EF0~7","en":"External fault EF0-7"},{"bit":8,"ko":"하드웨어 고장 CPF(oFA 포함)","en":"Hardware fault CPF (incl. oFA)"},{"bit":9,"ko":"모터 과부하(oL1)·과토크(oL3/oL4)·저토크(UL3/UL4)","en":"Motor overload (oL1), overtorque (oL3/oL4), undertorque (UL3/UL4)"},{"bit":10,"ko":"PG 단선(PGo)·과속(oS)·속도 편차(dEv)","en":"PG disconnected (PGo), overspeed (oS), speed deviation (dEv)"},{"bit":11,"ko":"주회로 저전압(Uv)","en":"Main circuit undervoltage (Uv)"},{"bit":12,"ko":"저전압(Uv1)·제어 전원 저전압(Uv2)·충전 회로 이상(Uv3)","en":"Undervoltage (Uv1), control power undervoltage (Uv2), soft charge fault (Uv3)"},{"bit":13,"ko":"출력 결상(LF)·입력 결상(PF)","en":"Output phase loss (LF), input phase loss (PF)"},{"bit":14,"ko":"MEMOBUS 통신 오류(CE)·옵션 통신 오류(bUS)","en":"MEMOBUS communication error (CE), option communication error (bUS)"},{"bit":15,"ko":"오퍼레이터 연결 이상(oPr)","en":"Operator connection fault (oPr)"}],"ref":"p.449","source":0},{"table":"holding-registers","address":34,"manualAddress":"0022H","type":"u16","name":{"ko":"데이터 링크 상태","en":"Data link status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"데이터 쓰기 중 또는 모터 전환 중","en":"Writing data or switching motors"},{"bit":3,"ko":"상·하한 오류","en":"Upper or lower limit error"},{"bit":4,"ko":"데이터 정합 오류","en":"Data conformity error"},{"bit":5,"ko":"EEPROM 쓰기 중","en":"Writing to EEPROM"}],"ref":"p.449","source":0},{"table":"holding-registers","address":35,"manualAddress":"0023H","type":"u16","name":{"ko":"주파수 지령(모니터)","en":"Frequency reference (monitor)"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"단위는 o1-03(초기값 0 = 0.01 Hz) (p.456 주 <1>)","en":"Unit set by o1-03 (default 0 = 0.01 Hz) (p.456 note <1>)"},"ref":"p.449","source":0},{"table":"holding-registers","address":36,"manualAddress":"0024H","type":"u16","name":{"ko":"출력 주파수","en":"Output frequency"},"unit":"Hz","scale":0.01,"access":"r","fc":[3],"description":{"ko":"단위는 o1-03(초기값 0 = 0.01 Hz) (p.456 주 <1>)","en":"Unit set by o1-03 (default 0 = 0.01 Hz) (p.456 note <1>)"},"ref":"p.449","source":0},{"table":"holding-registers","address":37,"manualAddress":"0025H","type":"u16","name":{"ko":"출력 전압 지령","en":"Output voltage reference"},"unit":"V","scale":0.1,"access":"r","fc":[3],"description":{"ko":"H5-10 = 0(초기값)일 때 0.1 V, 1 이면 1 V 단위","en":"0.1 V when H5-10 = 0 (default), 1 V when 1"},"ref":"p.449","source":0},{"table":"holding-registers","address":38,"manualAddress":"0026H","type":"u16","name":{"ko":"출력 전류","en":"Output current"},"unit":"A","access":"r","fc":[3],"description":{"ko":"배율은 형번별: BA0001~BA0018·2A0001~2A0040·4A0001~4A0023 은 0.01 A, 2A0056~2A0069·4A0031~4A0038 은 0.1 A (p.456 주 <2>)","en":"Scale by model: BA0001-BA0018, 2A0001-2A0040, 4A0001-4A0023 = 0.01 A; 2A0056-2A0069, 4A0031-4A0038 = 0.1 A (p.456 note <2>)"},"ref":"p.449","source":0},{"table":"holding-registers","address":39,"manualAddress":"0027H","type":"u16","name":{"ko":"출력 전력","en":"Output power"},"access":"r","fc":[3],"description":{"ko":"데이터 표에 단위가 없다","en":"No unit given in the data table"},"ref":"p.449","source":0},{"table":"holding-registers","address":41,"manualAddress":"0029H","type":"u16","name":{"ko":"고장 내용 2","en":"Fault contents 2"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"IGBT 단락·지락(SC)","en":"IGBT short circuit or ground fault (SC)"},{"bit":1,"ko":"지락(GF)","en":"Ground fault (GF)"},{"bit":2,"ko":"입력 결상(PF)","en":"Input phase loss (PF)"},{"bit":3,"ko":"출력 결상(LF)","en":"Output phase loss (LF)"},{"bit":4,"ko":"제동 저항 과열(rH)","en":"Braking resistor overheat (rH)"},{"bit":6,"ko":"모터 과열 2 PTC(oH4)","en":"Motor overheat 2, PTC input (oH4)"}],"ref":"p.450","source":0},{"table":"holding-registers","address":42,"manualAddress":"002AH","type":"u16","name":{"ko":"경보 내용 1","en":"Alarm contents 1"},"access":"r","fc":[3],"bits":[{"bit":2,"ko":"운전 지령 입력 오류(EF)","en":"Run command input error (EF)"},{"bit":3,"ko":"베이스블록(bb)","en":"Drive baseblock (bb)"},{"bit":4,"ko":"과토크 검출 1(oL3)","en":"Overtorque detection 1 (oL3)"},{"bit":5,"ko":"방열판 과열(oH)","en":"Heatsink overheat (oH)"},{"bit":6,"ko":"과전압(ov)","en":"Overvoltage (ov)"},{"bit":7,"ko":"저전압(Uv)","en":"Undervoltage (Uv)"},{"bit":9,"ko":"MEMOBUS 통신 오류(CE)","en":"MEMOBUS communication error (CE)"},{"bit":10,"ko":"옵션 통신 오류(bUS)","en":"Option communication error (bUS)"},{"bit":11,"ko":"저토크 검출 1/2(UL3/UL4)","en":"Undertorque detection 1/2 (UL3/UL4)"},{"bit":12,"ko":"모터 과열(oH3)","en":"Motor overheat (oH3)"},{"bit":13,"ko":"PID 피드백 상실(FbL/FbH)","en":"PID feedback loss (FbL, FbH)"},{"bit":15,"ko":"시리얼 통신 전송 오류(CALL)","en":"Serial communication transmission error (CALL)"}],"ref":"p.450","source":0},{"table":"holding-registers","address":43,"manualAddress":"002BH","type":"u16","name":{"ko":"입력 단자 상태","en":"Input terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"S1 닫힘","en":"Terminal S1 closed"},{"bit":1,"ko":"S2 닫힘","en":"Terminal S2 closed"},{"bit":2,"ko":"S3 닫힘","en":"Terminal S3 closed"},{"bit":3,"ko":"S4 닫힘","en":"Terminal S4 closed"},{"bit":4,"ko":"S5 닫힘","en":"Terminal S5 closed"},{"bit":5,"ko":"S6 닫힘","en":"Terminal S6 closed"},{"bit":6,"ko":"S7 닫힘","en":"Terminal S7 closed"}],"ref":"p.450","source":0},{"table":"holding-registers","address":44,"manualAddress":"002CH","type":"u16","name":{"ko":"드라이브 상태 2","en":"Drive status 2"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"영속도","en":"Zero speed"},{"bit":2,"ko":"속도 일치","en":"Speed agree"},{"bit":3,"ko":"사용자 속도 일치","en":"User speed agree"},{"bit":4,"ko":"주파수 검출 1","en":"Frequency detection 1"},{"bit":5,"ko":"주파수 검출 2","en":"Frequency detection 2"},{"bit":6,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":7,"ko":"저전압 중","en":"During undervoltage"},{"bit":8,"ko":"베이스블록 중","en":"During baseblock"},{"bit":9,"ko":"주파수 지령이 오퍼레이터","en":"Frequency reference from operator keypad"},{"bit":10,"ko":"운전 지령이 오퍼레이터","en":"Run command from operator keypad"},{"bit":11,"ko":"과토크/저토크 1·2","en":"Over/undertorque 1, 2"},{"bit":12,"ko":"주파수 지령 상실","en":"Frequency reference loss"},{"bit":13,"ko":"고장 재시작 중","en":"During fault restart"},{"bit":14,"ko":"고장","en":"Fault"},{"bit":15,"ko":"통신 타임아웃","en":"Communication timeout"}],"ref":"p.451","source":0},{"table":"holding-registers","address":45,"manualAddress":"002DH","type":"u16","name":{"ko":"출력 단자 상태","en":"Output terminal status"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"다기능 접점 출력(MA/MB-MC)","en":"Multi-function contact output (MA/MB-MC)"},{"bit":1,"ko":"다기능 포토커플러 출력 1(P1-PC)","en":"Multi-function photocoupler output 1 (P1-PC)"},{"bit":2,"ko":"다기능 포토커플러 출력 2(P2-PC)","en":"Multi-function photocoupler output 2 (P2-PC)"}],"ref":"p.451","source":0},{"table":"holding-registers","address":49,"manualAddress":"0031H","type":"u16","name":{"ko":"DC 버스 전압","en":"DC bus voltage"},"unit":"V","access":"r","fc":[3],"ref":"p.451","source":0},{"table":"holding-registers","address":56,"manualAddress":"0038H","type":"u16","name":{"ko":"PID 피드백","en":"PID feedback"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"부호 없음, 100% = 최대 출력 주파수","en":"Unsigned, 100% = max. output frequency"},"ref":"p.451","source":0},{"table":"holding-registers","address":57,"manualAddress":"0039H","type":"s16","name":{"ko":"PID 입력","en":"PID input"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"100% = 최대 출력 주파수","en":"100% = max. output frequency"},"ref":"p.451","source":0},{"table":"holding-registers","address":58,"manualAddress":"003AH","type":"s16","name":{"ko":"PID 출력","en":"PID output"},"unit":"%","scale":0.1,"access":"r","fc":[3],"description":{"ko":"100% = 최대 출력 주파수","en":"100% = max. output frequency"},"ref":"p.451","source":0},{"table":"holding-registers","address":61,"manualAddress":"003DH","type":"u16","name":{"ko":"통신 오류 내용","en":"Communications error log"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"CRC 오류","en":"CRC error"},{"bit":1,"ko":"데이터 길이 오류","en":"Data length error"},{"bit":3,"ko":"패리티 오류","en":"Parity error"},{"bit":4,"ko":"오버런 오류","en":"Overrun error"},{"bit":5,"ko":"프레이밍 오류","en":"Framing error"},{"bit":6,"ko":"타임아웃","en":"Timeout"}],"description":{"ko":"고장 리셋까지 유지","en":"Kept until fault reset"},"ref":"p.451","source":0},{"table":"holding-registers","address":75,"manualAddress":"004BH","type":"u16","name":{"ko":"드라이브 상태(U1-12)","en":"Drive status (U1-12)"},"access":"r","fc":[3],"bits":[{"bit":0,"ko":"운전 중","en":"During run"},{"bit":1,"ko":"영속도 중","en":"During zero speed"},{"bit":2,"ko":"역방향 운전 중","en":"During reverse run"},{"bit":3,"ko":"고장 리셋 신호 입력 중","en":"During fault reset signal input"},{"bit":4,"ko":"속도 일치 중","en":"During speed agree"},{"bit":5,"ko":"운전 준비 완료","en":"Drive ready"},{"bit":6,"ko":"경보","en":"Alarm"},{"bit":7,"ko":"고장","en":"Fault"},{"bit":8,"ko":"설정 오류(oPE) 중","en":"During operation error (oPE)"},{"bit":9,"ko":"순간 정전 중","en":"During momentary power loss"},{"bit":10,"ko":"모터 2 선택","en":"Motor 2 selected"},{"bit":14,"ko":"ComRef·NetRef 상태","en":"ComRef / NetRef status"},{"bit":15,"ko":"ComCtrl·NetCtrl 상태","en":"ComCtrl / NetCtrl status"}],"ref":"p.452","source":0},{"table":"holding-registers","address":127,"manualAddress":"007FH","type":"u16","name":{"ko":"경보 코드","en":"Alarm code"},"access":"r","fc":[3],"description":{"ko":"코드 뜻은 p.458 경보 레지스터 표","en":"Code meanings: alarm register table p.458"},"ref":"p.452","source":0},{"table":"holding-registers","address":128,"manualAddress":"0080H","type":"u16","name":{"ko":"현재 고장(U2-01)","en":"Current fault (U2-01)"},"access":"r","fc":[3],"values":[{"value":2,"ko":"Uv1 주회로 저전압","en":"Uv1 undervoltage"},{"value":3,"ko":"Uv2 제어 전원 저전압","en":"Uv2 control power supply undervoltage"},{"value":4,"ko":"Uv3 충전 회로 이상","en":"Uv3 soft charge circuit fault"},{"value":6,"ko":"GF 지락","en":"GF ground fault"},{"value":7,"ko":"oC 과전류","en":"oC overcurrent"},{"value":8,"ko":"ov 과전압","en":"ov overvoltage"},{"value":9,"ko":"oH 방열판 과열","en":"oH heatsink overheat"},{"value":10,"ko":"oH1 방열판 과열","en":"oH1 heatsink overheat"},{"value":11,"ko":"oL1 모터 과부하","en":"oL1 motor overload"},{"value":12,"ko":"oL2 드라이브 과부하","en":"oL2 drive overload"},{"value":13,"ko":"oL3 과토크 검출 1","en":"oL3 overtorque detection 1"},{"value":14,"ko":"oL4 과토크 검출 2","en":"oL4 overtorque detection 2"},{"value":27,"ko":"PF 입력 결상","en":"PF input phase loss"},{"value":28,"ko":"LF 출력 결상","en":"LF output phase loss"},{"value":33,"ko":"CE MEMOBUS/Modbus 통신 오류","en":"CE MEMOBUS/Modbus communication error"}],"description":{"ko":"값은 고장 코드(표 C.4). 일부만 실었다","en":"Value is a fault code (Table C.4); only some listed"},"ref":"p.400, p.457 표 C.4","source":0},{"table":"holding-registers","address":129,"manualAddress":"0081H","type":"u16","name":{"ko":"직전 고장(U2-02)","en":"Previous fault (U2-02)"},"access":"r","fc":[3],"values":[{"value":2,"ko":"Uv1 주회로 저전압","en":"Uv1 undervoltage"},{"value":3,"ko":"Uv2 제어 전원 저전압","en":"Uv2 control power supply undervoltage"},{"value":4,"ko":"Uv3 충전 회로 이상","en":"Uv3 soft charge circuit fault"},{"value":6,"ko":"GF 지락","en":"GF ground fault"},{"value":7,"ko":"oC 과전류","en":"oC overcurrent"},{"value":8,"ko":"ov 과전압","en":"ov overvoltage"},{"value":9,"ko":"oH 방열판 과열","en":"oH heatsink overheat"},{"value":10,"ko":"oH1 방열판 과열","en":"oH1 heatsink overheat"},{"value":11,"ko":"oL1 모터 과부하","en":"oL1 motor overload"},{"value":12,"ko":"oL2 드라이브 과부하","en":"oL2 drive overload"},{"value":13,"ko":"oL3 과토크 검출 1","en":"oL3 overtorque detection 1"},{"value":14,"ko":"oL4 과토크 검출 2","en":"oL4 overtorque detection 2"},{"value":27,"ko":"PF 입력 결상","en":"PF input phase loss"},{"value":28,"ko":"LF 출력 결상","en":"LF output phase loss"},{"value":33,"ko":"CE MEMOBUS/Modbus 통신 오류","en":"CE MEMOBUS/Modbus communication error"}],"description":{"ko":"값은 고장 코드(표 C.4). 일부만 실었다","en":"Value is a fault code (Table C.4); only some listed"},"ref":"p.400, p.457 표 C.4","source":0},{"table":"holding-registers","address":152,"manualAddress":"0098H","type":"u16","name":{"ko":"누적 운전 시간(U4-01) 10 h 단위","en":"Cumulative operation time (U4-01), 10 h units"},"unit":"h","scale":10,"access":"r","fc":[3],"description":{"ko":"12345 h 이면 0098H = 1234, 0099H = 5","en":"For 12345 h: 0098H = 1234, 0099H = 5"},"ref":"p.452","source":0},{"table":"holding-registers","address":153,"manualAddress":"0099H","type":"u16","name":{"ko":"누적 운전 시간(U4-01) 1 h 자리","en":"Cumulative operation time (U4-01), 1 h digit"},"unit":"h","access":"r","fc":[3],"ref":"p.452","source":0},{"table":"holding-registers","address":171,"manualAddress":"00ABH","type":"u16","name":{"ko":"드라이브 정격 전류","en":"Drive rated current"},"unit":"A","access":"r","fc":[3],"description":{"ko":"배율은 0026H 와 같이 형번별(0.01 A 또는 0.1 A) (p.456 주 <2>)","en":"Scale by model as for 0026H (0.01 A or 0.1 A) (p.456 note <2>)"},"ref":"p.452","source":0},{"table":"holding-registers","address":2304,"manualAddress":"0900H","type":"u16","name":{"ko":"Enter 명령(EEPROM 저장)","en":"Enter command (save to EEPROM)"},"access":"w","fc":[16],"description":{"ko":"0 을 쓴다. 읽으면 오류(02H). EEPROM 쓰기 횟수 10만 회 제한","en":"Write 0. Reading returns error 02H. EEPROM limited to 100,000 writes"},"ref":"p.459","source":0},{"table":"holding-registers","address":2320,"manualAddress":"0910H","type":"u16","name":{"ko":"Enter 명령(RAM 만)","en":"Enter command (RAM only)"},"access":"w","fc":[16],"description":{"ko":"0 을 쓴다. 전원을 끄면 변경 내용이 사라진다","en":"Write 0. Changes are lost at power-off"},"ref":"p.459","source":0}],"notes":[{"ko":"통신으로 운전·주파수를 주려면 b1-02 = 2, b1-01 = 2 (p.442 표 C.1).","en":"To run and set frequency by communication set b1-02 = 2 and b1-01 = 2 (p.442 Table C.1)."}],"sources":[{"title":"YASKAWA AC Drive-V1000 Compact Vector Control Drive Technical Manual (SIEP C710606 18F)","publisher":"YASKAWA ELECTRIC CORPORATION","edition":{"ko":"SIEP C710606 18F <6>, 2016년 12월 발행","en":"SIEP C710606 18F <6>, published December 2016"},"url":"https://www.yaskawa.com/delegate/getAttachment?documentId=SIEPC71060618&cmd=documents&documentName=SIEPC71060618.pdf","pages":{"ko":"부록 C MEMOBUS/Modbus p.434~459, U 모니터 표 p.399~400","en":"Appendix C MEMOBUS/Modbus pp.434-459, U monitor table pp.399-400"},"checked":"2026-10-23"}]}]}